Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 149
Filtrar
1.
Comput Biol Med ; 182: 109219, 2024 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-39362004

RESUMEN

Breast cancer remains a leading cause of cancer mortality worldwide, with early detection crucial for improving outcomes. This systematic review evaluates recent advances in portable non-invasive technologies for early breast cancer detection, assessing their methods, performance, and potential for clinical implementation. A comprehensive literature search was conducted across major databases for relevant studies published between 2015 and 2024. Data on technology types, detection methods, and diagnostic performance were extracted and synthesized from 41 included studies. The review examined microwave imaging, electrical impedance tomography (EIT), thermography, bioimpedance spectroscopy (BIS), and pressure sensing technologies. Microwave imaging and EIT showed the most promise, with some studies reporting sensitivities and specificities over 90 %. However, most technologies are still in early stages of development with limited large-scale clinical validation. These innovations could complement existing gold standards, potentially improving screening rates and outcomes, especially in underserved populations, whiles decreasing screening waiting times in developed countries. Further research is therefore needed to validate their clinical efficacy, address implementation challenges, and assess their impact on patient outcomes before widespread adoption can be recommended.

2.
Arch Med Sci ; 20(4): 1101-1109, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39439690

RESUMEN

Introduction: Chronic heart failure (HF) represents a major global public health problem, and despite significant advances in diagnosis and management over the past two decades, HF patients still have a poor prognosis. The aim of the study was to evaluate the relationship between lung congestion, as assessed by lung ultrasonography (LUS), bioimpedance spectroscopy, body fluid compartments, and echocardiographic parameters, and to determine the effect of these associations on all-cause mortality in HF patients. Material and methods: Eligible patients with a left ventricular ejection fraction (LVEF) below 45% were identified via daily echocardiography assessments. Lung ultrasonography was performed with patients in the supine position, for a total of 28 sites per complete examination. The extracellular water (ECW) was determined using a BIS device. Results: Our study included 122 patients (67.2% males) with a mean age of 67.2 years. In the multivariable linear regression analysis, including all the univariable predictors of lung congestion, only New York Heart Association (NYHA) class, ECW, estimated glomerular filtration rate (eGFR), and LVEF levels maintained an independent association with the number of B-lines. During the follow-up, 33 patients died. In multivariable Cox analysis, a B-line number of at least 15 remained significantly associated with all-cause mortality, independently of age, sex, diabetes, LVEF, estimated glomerular filtration rate, C-reactive protein, N-terminal pro-brain natriuretic peptide, or ECW values (adjusted HR = 3.84, 95% CI: 1.12-13.09). Conclusions: We show for the first time in HF patients that pulmonary congestion, as assessed by LUS, is associated with the severity of NYHA class, LVEF, eGFR, and ECW, and it identifies those at increased risk of death.

3.
Eur J Breast Health ; 20(4): 251-257, 2024 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-39323290

RESUMEN

Objective: Breast cancer-related lymphedema (BCRL) is a common complication of breast cancer treatment that may result in swelling of the affected arm due to compromised lymphatic function. Implementing a screening program and early intervention for BCRL are important for effective management. Bioimpedance spectroscopy (BIS) is a commonly used tool for assessing BCRL. This study aimed to compare different normative ranges for BIS L-Dex scores in the detection of BCRL. Materials and Methods: Data from 158 women with clinically ascribed and indocyanine green confirmed BCRL were analysed. BIS measurements were obtained using an ImpediMed standing device, and L-Dex scores were calculated using published normative ranges for healthy individuals. Statistical analysis was performed to compare the concordance between different reference ranges in classifying individuals with lymphedema. Results: The study found that L-Dex scores calculated using different normative ranges were highly correlated and essentially interchangeable in detecting BCRL. Approximately 90% of participants exceeded the L-Dex threshold for lymphedema, with minimal discrepancies between reference ranges. False negative rates were observed in some participants, likely due to early-stage BCRL with minimal lymph accumulation. Conclusion: The findings suggest that BIS L-Dex scores are a valid indicator of BCRL, regardless of specific normative ranges used. Detection rates of clinically confirmed BCRL were consistent across different reference ranges, with minimal discrepancies. BIS remains a valuable tool for early detection and monitoring of BCRL. Future research should focus on longitudinal assessments and use of change in L-Dex scores for lymphedema monitoring and progression.

4.
Sensors (Basel) ; 24(16)2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39204905

RESUMEN

One of the most promising approaches to food quality assessments is the use of impedance spectroscopy combined with machine learning. Thereby, feature selection is decisive for a high classification accuracy. Physically based features have particularly significant advantages because they are able to consider prior knowledge and to concentrate the data into pertinent understandable information, building a solid basis for classification. In this study, we aim to identify physically based measurable features for muscle type and freshness classifications of bovine meat based on impedance spectroscopy measurements. We carry out a combined study where features are ranked based on their F1-score, cumulative feature selection, and t-distributed Stochastic Neighbor Embedding (t-SNE). In terms of features, we analyze the characteristic points (CPs) of the impedance spectrum and the model parameters (MPs) obtained by fitting a physical model to the measurements. The results show that either MPs or CPs alone are sufficient for detecting muscle type. Combining capacitance (C) and extracellular resistance (Rex) or the modulus of the characteristic point Z1 and the phase at the characteristic frequency of the beta dispersion (Phi2) leads to accurate separation. In contrast, the detection of freshness is more challenging. It requires more distinct features. We achieved a 90% freshness separation using the MPs describing intracellular resistance (Rin) and capacitance (C). A 95.5% freshness separation was achieved by considering the phase at the end of the beta dispersion (Phi3) and Rin. Including additional features related to muscle type improves the separability of samples; ultimately, a 99.6% separation can be achieved by selecting the appropriate features.


Asunto(s)
Espectroscopía Dieléctrica , Espectroscopía Dieléctrica/métodos , Animales , Bovinos , Carne/análisis , Aprendizaje Automático , Impedancia Eléctrica , Algoritmos
5.
IEEE J Transl Eng Health Med ; 12: 533-541, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39155919

RESUMEN

The equivalent electrical circuit approach is explored to improve a bioimpedance-based transducer for measuring the bioavailability of synthetic insulin already presented in previous studies. In particular, the electrical parameter most sensitive to the variation of insulin amount injected was identified. Eggplants were used to emulate human electrical behavior under a quasi-static assumption guaranteed by a very low measurement time compared to the estimated insulin absorption time. Measurements were conducted with the EVAL-AD5940BIOZ by applying a sinusoidal voltage signal with an amplitude of 100 mV and acquiring impedance spectra in the range [1-100] kHz. 14 units of insulin were gradually administered using a Lilly's Insulin Pen having a 0.4 cm long needle. Modified Hayden's model was adopted as a reference circuit and the electrical component modeling the extracellular fluids was found to be the most insulin-sensitive parameter. The trnasducer achieves a state-of-the-art sensitivity of 225.90 ml1. An improvement of 223 % in sensitivity, 44 % in deterministic error, 7 % in nonlinearity, and 42 % in reproducibility was achieved compared to previous experimental studies. The clinical impact of the transducer was evaluated by projecting its impact on a Smart Insulin Pen for real-time measurement of insulin bioavailability. The wide gain in sensitivity of the bioimpedance-based transducer results in a significant reduction of the uncertainty of the Smart Insulin Pen. Considering the same improvement in in-vivo applications, the uncertainty of the Smart Insulin Pen is decreased from [Formula: see text]l to [Formula: see text]l.Clinical and Translational Impact Statement: A Smart Insulin Pen based on impedance spectroscopy and equivalent electrical circuit approach could be an effective solution for the non-invasive and real-time measurement of synthetic insulin uptake after subcutaneous administration.


Asunto(s)
Disponibilidad Biológica , Insulina , Insulina/administración & dosificación , Insulina/farmacocinética , Humanos , Impedancia Eléctrica , Transductores , Espectroscopía Dieléctrica , Diseño de Equipo
6.
Ann Surg Oncol ; 31(11): 7487-7495, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38965099

RESUMEN

BACKGROUND: The PREVENT randomized control trial monitored progression to chronic breast cancer-related lymphedema (cBCRL) following intervention for subclinical breast cancer-related lymphedema (sBCRL) assessed by bioimpedance spectroscopy (BIS) versus tape-measure (TM). This multi-institutional trial demonstrated a 92% risk reduction of developing cBCRL. This secondary analysis reviews the timing of sBCRL and cBCRL following breast cancer (BC) treatment. PATIENTS AND METHODS: Women at risk of cBCRL (n = 919) were screened regularly up to 36 months after BC treatment using either BIS or TM. Following diagnosis of sBCRL, patients underwent a 4-week compression sleeve intervention. The time in months from BC treatment to detection was reviewed at 3-month intervals. RESULTS: In total 209 patients developed sBCRL (BIS: n = 89, TM: n = 120) and were eligible for intervention. 30 progressed to cBCRL postintervention (BIS: 7, TM: 23). More than half of patients had measurements consistent with sBCRL within 9 months of BC treatment. Patients continued to have initial detections of sBCRL, regardless of screening method, with rates remaining consistent in years two and three (p > 0.242) post surgery. Additionally, 39 patients progressed to cBCRL without developing sBCRL or receiving intervention across the 3-year period. CONCLUSIONS: The timing of sBCRL detection demonstrates that patients continue to be at risk years after treatment and may continue to progress to cBCRL years after surgery. Early detection of sBCRL allows for early intervention decreasing the likelihood of progression to cBCRL. Patients should continue to be monitored for a minimum of 3 years following completion of cancer treatment. Specifically, careful targeted monitoring over the initial 9-month period is important.


Asunto(s)
Neoplasias de la Mama , Espectroscopía Dieléctrica , Humanos , Femenino , Estudios Prospectivos , Espectroscopía Dieléctrica/métodos , Neoplasias de la Mama/complicaciones , Neoplasias de la Mama/cirugía , Persona de Mediana Edad , Estudios de Seguimiento , Linfedema del Cáncer de Mama/diagnóstico , Linfedema del Cáncer de Mama/etiología , Linfedema del Cáncer de Mama/terapia , Factores de Tiempo , Pronóstico , Anciano , Adulto , Progresión de la Enfermedad
7.
Sensors (Basel) ; 24(14)2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39066045

RESUMEN

Muscle dysfunction and muscle atrophy are common complications resulting from Chronic Obstructive Pulmonary Disease (COPD). The evaluation of the peripheral muscles can be carried out through the assessment of their structural components from ultrasound images or their functional components through isometric and isotonic strength tests. This evaluation, performed mainly on the quadriceps muscle, is not only of great interest for diagnosis, prognosis and monitoring of COPD, but also for the evaluation of the benefits of therapeutic interventions. In this work, bioimpedance spectroscopy technology is proposed as a low-cost and easy-to-use alternative for the evaluation of peripheral muscles, becoming a feasible alternative to ultrasound images and strength tests for their application in routine clinical practice. For this purpose, a laboratory prototype of a bioimpedance device has been adapted to perform segmental measurements in the quadriceps region. The validation results obtained in a pseudo-randomized study in patients with COPD in a controlled clinical environment which involved 33 volunteers confirm the correlation and correspondence of the bioimpedance parameters with respect to the structural and functional parameters of the quadriceps muscle, making it possible to propose a set of prediction equations. The main contribution of this manuscript is the discovery of a linear relationship between quadriceps muscle properties and the bioimpedance Cole model parameters, reaching a correlation of 0.69 and an average error of less than 0.2 cm regarding the thickness of the quadriceps estimations from ultrasound images, and a correlation of 0.77 and an average error of 3.9 kg regarding the isometric strength of the quadriceps muscle.


Asunto(s)
Impedancia Eléctrica , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Masculino , Músculo Cuádriceps/fisiopatología , Músculo Cuádriceps/diagnóstico por imagen , Músculo Cuádriceps/fisiología , Persona de Mediana Edad , Anciano , Femenino , Espectroscopía Dieléctrica/métodos , Espectroscopía Dieléctrica/instrumentación , Fuerza Muscular/fisiología , Músculo Esquelético/fisiopatología , Músculo Esquelético/diagnóstico por imagen
8.
Front Oncol ; 14: 1418610, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39081716

RESUMEN

Background: Breast cancer-related lymphedema (BCRL) profoundly impacts patients' quality of life, causing heightened depression, anxiety, and physical limitations. Surgical removal of the axillary nodes, combined with radiation therapy, is a significant risk factor for BCRL. Smarter axillary surgery, coupled with early detection and fostering lymphedema education, significantly improves BCRL management, promoting timely diagnosis and treatment. A lymphedema prevention program encompassing all these factors can significantly aid in preventing, treating, and reducing the severity of BCRL cases. Therefore, our study aims to share our insights and experiences gained from implementing a lymphedema prevention program at our institution. Methods & Results: At our institution, axillary reverse mapping (ARM) is performed on all patients undergoing axillary surgery. We surveil these patients with pre- and postoperative SOZO® measurements using bioimpedance spectroscopy to detect sub-clinical lymphedema. Concerning education, we use a 3-pronged approach with surgeons, nurse practitioners, and video representation for patients. We have had 212 patients undergo the ARM procedure since 2019, with three (1.41%) developing persistent lymphedema. Conclusion: Our study underscores the significance of a comprehensive lymphedema prevention program, integrating smarter axillary surgery, early detection, and patient education. The lymphedema rate of 1.41% not only validates the success rate of these interventions but also advocates for their widespread adoption to enhance the holistic care of breast cancer survivors. As we continue to refine and expand our program, further research, and long-term follow-up are crucial to improve prevention strategies continually and enhance the overall well-being of individuals at risk of BCRL.

9.
Transpl Int ; 37: 12879, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38915756

RESUMEN

In this longitudinal observational study, we measured urinary glucose concentration, body composition and volume status (bioimpedance spectroscopy) and plasma renin and aldosterone concentrations in n = 22 kidney transplant recipients (KTRs) initiating on SGLT2I at baseline (BL), and after 1 week and 1, 3, and 6 months. Estimated glomerular filtration rate (eGFR) decreased by -2 mL/min/1.73 m2 (IQR -10-0) after 1 week and remained stable thereafter. Urinary glucose concentration was 10 (3-24) g/g creatinine after 1 week and correlated with eGFR (r2 = 0.273; p = 0.057). SGLT2I did not affect HbA1c, fasting blood glucose, body weight, fat or lean mass. SGLT2I decreased fluid overload dependent on baseline overhydration (OH, r2 = 0.54, p = 0.0003) without occurrence of dehydration. Plasma aldosterone increased at day 7, while plasma renin did not change significantly. In conclusion, SGLT2I corrected fluid overload in patients with elevated overhydration at baseline, while in euvolemic KTRs fluid status remained stable without reduction of body water below the reference range, thus promoting the safety of SGLT2I therapy in patients following kidney transplantation. Glucosuria, together with effects of SGLT2I on blood glucose control and body weight, is attenuated in KTRs dependent on eGFR.


Asunto(s)
Tasa de Filtración Glomerular , Trasplante de Riñón , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Humanos , Trasplante de Riñón/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Inhibidores del Cotransportador de Sodio-Glucosa 2/uso terapéutico , Estudios Longitudinales , Adulto , Aldosterona/sangre , Anciano , Renina/sangre , Desequilibrio Hidroelectrolítico/etiología , Composición Corporal , Glucemia/análisis , Glucemia/metabolismo , Receptores de Trasplantes
10.
Pediatr Nephrol ; 39(10): 3057-3066, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38839693

RESUMEN

BACKGROUND: Accurate volume status assessment and dry weight achievement are the most challenging goals for a nephrologist. We aimed to evaluate the role of ultrasonographic parameters including lung ultrasound and inferior vena cava (IVC) measurements as practical methods of volume status assessment in children on hemodialysis by comparing them with established techniques, such as clinical evaluation and bioimpedance spectroscopy. METHODS: A prospective cross-sectional study compared pre- and post-dialysis volume status using bioimpedance spectroscopy (BIS) parameters and clinical data with ultrasonographic lung B-lines and IVC parameters in children on regular hemodialysis. RESULTS: A total 60 children (mean age 9.4 ± 2.8 years) were enrolled. Twenty patients (33.3%) were clinically overloaded to varying degrees (17 patients had mild to moderate signs of fluid overload and 3 patients had moderate to severe signs of fluid overload). All other patients (66.7%) were clinically euvolemic. Sonographic parameters were significantly lower post-dialysis than pre-dialysis, including lung B-line count and IVC diameter. IVC collapsibility index mean was significantly higher post-dialysis than pre-dialysis. There was a significant correlation between the lung B-line count, IVC parameters, and BIS-measured overhydration both before and after hemodialysis. Nine patients had ≥ 8 B-lines post-dialysis, only three of them were hypertensive. CONCLUSIONS: Clinical criteria alone are not specific for determining accurate fluid status in pediatric hemodialysis patients. Lung B-line score, IVC parameters, and BIS may be complementary to each other and to clinical data. Lung B-lines outperform IVC measurements and BIS in subclinical volume overload detection in pediatric hemodialysis patients.


Asunto(s)
Pulmón , Diálisis Renal , Ultrasonografía , Vena Cava Inferior , Humanos , Diálisis Renal/efectos adversos , Niño , Masculino , Femenino , Estudios Transversales , Estudios Prospectivos , Vena Cava Inferior/diagnóstico por imagen , Adolescente , Pulmón/diagnóstico por imagen , Pulmón/patología , Preescolar , Espectroscopía Dieléctrica/métodos , Desequilibrio Hidroelectrolítico/etiología , Desequilibrio Hidroelectrolítico/diagnóstico , Volumen Sanguíneo
11.
Ann Surg Oncol ; 31(9): 5937-5946, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38844631

RESUMEN

BACKGROUND: Breast cancer-related lymphedema (BCRL) poses a significant risk following sentinel lymph node biopsy (SLNB) and axillary lymph node dissection (ALND), particularly affecting ethnic minorities, with a twofold increased risk. Axillary reverse mapping (ARM), a novel technique, shows potential in reducing BCRL rates, yet its utility in ethnic minorities lacks sufficient exploration. Therefore, our study aims to investigate the utility and outcomes of ARM on BCRL in an ethnic diverse group. METHODS: A retrospective chart review of ARM patients from January 2019 to July 2022 was conducted, monitoring patients over 24 months at 3-month intervals using SOZO® scores, with comparisons with preoperative baselines. RESULTS: Of the 212 patients, 83% belonged to ethnic minorities. SLNB was performed in 83%, ALND in 17%, and 62.3% underwent radiation therapy. Positive lymph nodes were found in 31.6%, with 22.2% exhibiting blue nodes and 25.9% exhibiting blue lymphatics. Of identified blue nodes, 70.2% were excised, including 51.5% crossover nodes. Lymphedema occurred in 3 patients, resulting in a BCRL rate of 1.4%. Compared with an historical BCRL incidence of 40.4% following ALND in ethnic minorities, our study reported a significantly lower rate of 8% (p < 0.001). CONCLUSION: The ARM procedure can significantly lower BCRL in ethnic minority groups. The combination of ARM and bioimpedance spectroscopy led to a remarkably low BCRL rate of 1.4%. Notably, none of the patients in our study developed an axillary recurrence at 24-month follow-up. Nevertheless, future studies with larger sample sizes are warranted to better understand the utility of the ARM technique in this population.


Asunto(s)
Axila , Linfedema del Cáncer de Mama , Neoplasias de la Mama , Escisión del Ganglio Linfático , Biopsia del Ganglio Linfático Centinela , Humanos , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Escisión del Ganglio Linfático/efectos adversos , Biopsia del Ganglio Linfático Centinela/efectos adversos , Estudios de Seguimiento , Linfedema del Cáncer de Mama/etiología , Anciano , Adulto , Pronóstico , Linfedema/etiología , Linfedema/prevención & control , Etnicidad/estadística & datos numéricos , Ganglios Linfáticos/patología , Ganglios Linfáticos/cirugía
12.
Physiol Meas ; 45(5)2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38604189

RESUMEN

Objective. Bioimpedance spectroscopy (BIS) is a popular technique for the assessment of body composition in children and adults but has not found extensive use in babies and infants. This due primarily to technical difficulties of measurement in these groups. Although improvements in data modelling have, in part, mitigated this issue, the problem continues to yield unacceptably high rates of poor quality data. This study investigated an alternative data modelling procedure obviating issues associated with BIS measurements in babies and infants.Approach.BIS data are conventionally analysed according to the Cole model describing the impedance response of body tissues to an appliedACcurrent. This approach is susceptible to errors due to capacitive leakage errors of measurement at high frequency. The alternative is to model BIS data based on the resistance-frequency spectrum rather than the reactance-resistance Cole model thereby avoiding capacitive error impacts upon reactance measurements.Main results.The resistance-frequency approach allowed analysis of 100% of data files obtained from BIS measurements in 72 babies compared to 87% successful analyses with the Cole model. Resistance-frequency modelling error (percentage standard error of the estimate) was half that of the Cole method. Estimated resistances at zero and infinite frequency were used to predict body composition. Resistance-based prediction of fat-free mass (FFM) exhibited a 30% improvement in the two-standard deviation limits of agreement with reference FFM measured by air displacement plethysmography when compared to Cole model-based predictions.Significance.This study has demonstrated improvement in the analysis of BIS data based on the resistance frequency response rather than conventional Cole modelling. This approach is recommended for use where BIS data are compromised by high frequency capacitive leakage errors such as those obtained in babies and infants.


Asunto(s)
Composición Corporal , Espectroscopía Dieléctrica , Impedancia Eléctrica , Humanos , Lactante , Espectroscopía Dieléctrica/métodos , Recién Nacido , Masculino , Femenino
13.
Cureus ; 16(3): e55906, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38601427

RESUMEN

Lower extremity swelling may be broadly characterized as due to edema, lymphedema, or lipedema. Differentiation between these three conditions is important for providing appropriate treatment. This review analyzes and compares different clinical diagnostic modalities for these conditions, with the aim of assisting in the process of choosing the most appropriate diagnostic modality by highlighting the advantages and limitations of each. Using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for a systematic search of peer-reviewed literature, the following diagnostic methods for lower extremity swelling were investigated: (1) ultrasound (US), (2) lymphoscintigraphy (LSG), (3) computed tomography (CT), (4) bioimpedance spectroscopy (BIS), (5) tissue dielectric constant (TDC), and (6) magnetic resonance imaging (MRI), including magnetic resonance lymphangiography (MRL). The databases used in the search were PubMed, ProQuest, CINAHL Complete, Web of Science, Embase, and Biomedical Reference Collection. After retrieving 115 studies based on predetermined inclusion criteria, a total of 31 studies were critically evaluated. The main results indicate the following: duplex US is the modality of choice to initially identify lower extremity edema such as deep venous thrombosis (DVT) and venous reflux due to its high sensitivity and specificity. CT venography of the lower extremity appears to bethe preferred option for gynecologic cancer patients with lower extremity swelling post-treatment, as it measures subcutaneous tissue volumes to look for DVTs, lymphoceles, and cancer recurrence. TDC is a recommended modality for a variety of conditions, including edema and lymphedema, in part, due to its noninvasive localized assessment capabilities and ease of use. LSG emerges as an effective imaging modality for lymphedema characterization with minimal invasiveness and high sensitivity and specificity. BIS is widely used to identify and monitor lower extremity lymphedema but has been reported to have low sensitivity and lacks the ability to account for changes in tissue composition such as fibrosis. US and MRL are favored for lipedema diagnosis, with MRL providing comprehensive anatomical and functional insights, albeit with cost and accessibility limitations compared to US. While CT, MRI, US, and TDC are all useful for differentiating lymphedema from lipedema, MRI is the preferred modality due to its anatomical and functional diagnostic capabilities. However, US is a pragmatic alternative for use with obese patients or when MRI is not an option.

14.
Eur J Breast Health ; 20(2): 141-148, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38571690

RESUMEN

Objective: Breast cancer related lymphedema (BCRL) may be assessed through objective measurement of limb swelling with common techniques including volumetric measurement using a tape measure or perometry, and measurement of extracellular water using bioimpedance spectroscopy (BIS). This study aimed to evaluate the performance of a stand-on BIS device for detection of BCRL, introduce a novel graphical method to compare volumetric and BIS methods alongside traditional specificity and sensitivity analysis, and determine and compare BIS thresholds with those published previously. Materials and Methods: Female participants with indocyanine green lymphography confirmed unilateral arm lymphedema (n = 197) and healthy controls (n = 267) were assessed using a cross-sectional study design. BIS and volumetric measures were obtained in a single session. Results: The BIS lymphedema index (L-Dex) method had a significantly higher sensitivity than the excess volume approach (area under the curve = 0.832 vs. 0.649, p = 0.0001). A threshold of L-Dex 6.5 had a higher true positive rate (70.6%) than L-Dex 10 (68.5%) although false positive rate increased from 0.4% to 2.6%. A threshold of 5% excess volume improved the true positive rate (68.5%) compared with 10% excess volume (49.7%) however the false positive rate increased to an unacceptable 47%. The L-Dex ranges in this study were not significantly different from previously published ranges. Conclusion: BIS was superior for identifying BCRL compared with volume measurements, reaffirming the value of this technique. However, it is recommended that BIS be used in conjunction with comprehensive evaluation of symptoms and clinical presentation. The proposed graphical method provides a simple and easily interpretable approach to compare and define concordance between the two commonly used methods for BCRL assessment namely limb volume and BIS L-Dex indices. The existing BIS (L-Dex) thresholds for presence of BCRL were also validated.

15.
Clin Obes ; 14(4): e12658, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38548674

RESUMEN

Lipoedema is the disproportionate accumulation of adipose tissue in the lower body, often associated with hormonal changes in women. Lipoedema is commonly misdiagnosed as lymphoedema or obesity due to similarities in appearance. The aim of this study is to compare body composition and fluid measures of women with lipoedema, lymphoedema, and matched control participants, to determine differences that may help distinguish between each condition. One hundred and eleven participants aged over 18, who presented with the complaint of leg swelling and underwent indocyanine green lymphography were included in this study. Our analysis showed that the individuals with lymphoedema had a significantly higher overall total body water (lymphoedema: 9.6 ± 4.2 L, lipoedema: 7.4 ± 2.3 L, control: 7.5 ± 1.8 L; p < .001) and extracellular fluid (lymphoedema: 4.6 ± 1.6, lipoedema: 3.4 ± 1.0 L, control: 3.5 ± 0.7 L; p < .001) in the legs when compared to individuals with lipoedema and matched control participants. Individuals with lipoedema had a significantly higher overall fat mass as a percentage of body weight when compared to individuals with lymphoedema (lymphoedema: 33.1% ± 9.5%, lipoedema: 39.4% ± 6.5%; p = .003). We are unable to distinguish between individuals with lipoedema and control participants, therefore further research needs to be conducted to help reduce misdiagnosis.


Asunto(s)
Composición Corporal , Lipedema , Linfedema , Humanos , Femenino , Linfedema/diagnóstico , Linfedema/fisiopatología , Lipedema/diagnóstico , Adulto , Persona de Mediana Edad , Estudios de Casos y Controles , Linfografía/métodos , Anciano , Diagnóstico Diferencial
16.
Ren Fail ; 46(1): 2313360, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38345032

RESUMEN

CONCLUSION: There were significant differences between Vwat and Vbis and between Kt/Vwat and Kt/Vbis. Kt/Vwat may underestimate small-solute dialysis adequacy in most cases. Kt/Vbis instead of Kt/Vwat could be accounted for in creating individualized dialysis prescriptions if the patient has no obvious clinical symptoms.


Asunto(s)
Diálisis Peritoneal , Urea , Humanos , Composición Corporal , Diálisis Renal/métodos , Análisis Espectral
17.
Kidney Blood Press Res ; 49(1): 124-134, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38228104

RESUMEN

INTRODUCTION: SGLT2 inhibitors are used to reduce the risk of progression of chronic kidney disease (CKD). In patients with type 2 diabetes, they have been found to reduce extracellular volume. Given the high prevalence of extracellular volume expansion and overhydration (OH) in CKD, we investigated whether SGLT2 inhibitors might correct these disturbances in CKD patients. METHODS: CKD patients who started treatment with an SGLT2 inhibitor were investigated in this prospective observational study for 6 months. Body composition and fluid status were measured by bioimpedance spectroscopy. In addition, spot urine samples were analyzed for albuminuria, glucosuria, and urinary aprotinin-sensitive serine protease activity. RESULTS: Forty-two patients (29% with diabetic/hypertensive CKD, 31% with IgA nephropathy; 88% dapagliflozin 10 mg, 10% dapagliflozin 5 mg, 2% empagliflozin 20 mg; median eGFR 46 mL/min/1.73 m2 and albuminuria 1,911 mg/g creatinine) participated in the study. Median glucosuria increased to 14 (10-19) g/g creatinine. At baseline, patients displayed OH with +0.4 (-0.2 to 2.2) L/1.73 m2, which decreased by 0.5 (0.1-1.2) L/1.73 m2 after 6 months. Decrease of OH correlated with higher OH at BL, decrease of albuminuria, glucosuria, and urinary aprotinin-sensitive protease activity. Adipose tissue mass was not significantly reduced after 6 months. CONCLUSION: SGLT2 inhibitors reduce OH in patients with CKD, which is pronounced in the presence of high albuminuria, glucosuria, and urinary aprotinin-sensitive protease activity.


Asunto(s)
Compuestos de Bencidrilo , Glucósidos , Insuficiencia Renal Crónica , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Humanos , Inhibidores del Cotransportador de Sodio-Glucosa 2/uso terapéutico , Inhibidores del Cotransportador de Sodio-Glucosa 2/farmacología , Insuficiencia Renal Crónica/tratamiento farmacológico , Insuficiencia Renal Crónica/orina , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Longitudinales , Glucósidos/uso terapéutico , Glucósidos/farmacología , Compuestos de Bencidrilo/uso terapéutico , Compuestos de Bencidrilo/farmacología , Estudios Prospectivos , Serina Proteasas , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/complicaciones
18.
J Nephrol ; 37(4): 993-1003, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38263531

RESUMEN

BACKGROUND: Estimation of muscle mass is a pivotal component in the diagnosis of protein-energy wasting and sarcopenia. While bioimpedance spectroscopy is a widely  accepted technique for the assessment of lean tissue related to the diagnosis of sarcopenia, to date skeletal muscle ultrasound (US) has not gained full acceptance for this purpose. The aim of this study was to assess the predictive value for mortality of the indexed thickness of the quadriceps vastus intermedius, as measured by US, compared to lean tissue index as estimated by bioimpedance spectroscopy, both combined with handgrip strength in a group of patients with end-stage kidney disease (ESKD) on maintenance hemodialysis (HD). METHODS: The cut-off values for low handgrip strength were < 27 kg for males and < 16 kg for females. The cut-off value for low lean tissue index was obtained from an age-matched healthy control group, with low lean tissue index being defined as values below the 10th percentile of the distribution of healthy subjects. The cut-off values for low quadriceps vastus intermedius thickness index were < 3.44 mm/m2 for males and < 3.52 mm/m2 for females. RESULTS: Ultrasound and bioimpedance spectroscopy were performed in 99 patients, and handgrip strength was assessed in 64 patients, all on maintenance HD. After a median follow-up of 28 months (interquartile range 19-41 months) 38 patients died. Lean tissue index was not associated with mortality, while low quadriceps vastus intermedius thickness index and low handgrip strength were associated with an increased hazard of death. In the fully adjusted model, only the combination of low handgrip strength and low quadriceps vastus intermedius thickness index was significantly associated with higher mortality. CONCLUSION: When combined with low handgrip strength, low quadriceps muscle US outperformed low lean tissue index as assessed by bioimpedance spectroscopy in predicting mortality in a cohort of patients on maintenance HD. Ultrasound may be a useful and convenient technique for the assessment of sarcopenia and protein-energy wasting in this patient population.


Asunto(s)
Fuerza de la Mano , Fallo Renal Crónico , Valor Predictivo de las Pruebas , Músculo Cuádriceps , Diálisis Renal , Sarcopenia , Ultrasonografía , Humanos , Masculino , Femenino , Sarcopenia/diagnóstico por imagen , Sarcopenia/fisiopatología , Sarcopenia/mortalidad , Músculo Cuádriceps/diagnóstico por imagen , Músculo Cuádriceps/fisiopatología , Persona de Mediana Edad , Anciano , Fallo Renal Crónico/terapia , Fallo Renal Crónico/fisiopatología , Fallo Renal Crónico/mortalidad , Fallo Renal Crónico/complicaciones , Espectroscopía Dieléctrica , Estudios de Casos y Controles
19.
Physiol Meas ; 45(2)2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38237199

RESUMEN

Objective. Bioimpedance spectroscopy (BIS) is a non-invasive diagnostic tool to derive fluid volume compartments from frequency dependent voltage drops in alternating currents by extrapolating to the extracellular resistance (R0) and intracellular resistance (Ri). Here we tested whether a novel BIS device with reusable and adhesive single-use electrodes produces results which are (in various body positions) equivalent to an established system employing only single-use adhesive electrodes.Approach. Two BIS devices ('Cella' and the 'Body Composition Monitor' [BCM]) were compared using four dedicated resistance testboxes and by measuring 40 healthy volunteers.Invivocomparisons included supine wrist-to-ankle (WA) reference measurements and wrist-to-wrist (WW) measurements with pre-gelled silver/silver-chloride (Ag/AgCl) electrodes and WW measurements with reusable gold-plated copper electrodes.Main results. Coefficient of variation were <1% for all testbox measurements with both BIS devices. Accuracy was within ±1% of true resistance variability, a threshold which was only exceeded by the Cella device for all resistances in a testbox designed with a lowR0/Riratio.Invivo, WA-BIS differed significantly between BIS devices (p< 0.001). Reusable WW electrodes exhibited larger resistances than WW-BIS with Ag/AgCl electrodes (R0: 738.36 and 628.69 Ω;Ri: 1508.18 and 1390 Ω) and the relative error varied from 7.6% to 31.1% (R0) and -15.6% to 37.3% (Ri).Significance. Both BIS devices produced equivalent resistances measurements but different estimates of body composition bothinsilicoand in WA setupsinvivo, suggesting that the devices should not be used interchangeably. Employing WW reusable electrodes as opposed to WA and WW measurement setups with pre-gelled Ag/AgCl electrodes seems to be associated with measurement variations that are too large for safe clinical use. We recommend further investigations of measurement errors originating from electrode material and current path.


Asunto(s)
Cobre , Plata , Humanos , Plata/química , Análisis Espectral , Composición Corporal , Electrodos , Impedancia Eléctrica
20.
Lymphat Res Biol ; 22(1): 43-54, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37851985

RESUMEN

Background: Bioimpedance spectroscopy (BIS) measurements are conventionally performed in supine position with a lead device attached to gel-backed electrodes, and more recently, with a stand-on device that uses fixed stainless-steel electrodes under the hands and feet. The aim of this study was to assess and compare BIS measurements made in supine, sitting, and standing positions using lead and stand-on impedance devices in participants with and without unilateral leg lymphedema. Materials and Methods: Participants with self-ascribed unilateral leg lymphedema (n = 24) and healthy controls (n = 71) were recruited using a cross-sectional study design. Triplicate BIS measurements were taken for each device in each position. Results: Impedance measurements with either device were reliable with coefficient of variation of 0.6% or lower. The magnitude of mean differences in absolute impedance values between devices were between 1% and 6% dependent on condition. L-Dex scores between the two devices were highly correlated (r = 0.82) and ∼70% of participants in the lymphedema group were classified as having lymphedema using the recommended cut-off with either device. There was no significant interleg difference of controls using the lead device; however, small, but significant differences (p = 0.0001) were found when using the stand-on device. Conclusion: The findings demonstrate that reliable impedance measurements of the legs can be made with either device in lying, sitting, or standing positions. However, data between the devices were not directly interchangeable. Although the risk of misidentification was small, reference ranges appropriate to the device and measurement position should be used when converting data to L-Dex scores.


Asunto(s)
Linfedema , Posicionamiento del Paciente , Humanos , Estudios Transversales , Pierna , Análisis Espectral , Linfedema/diagnóstico , Linfedema/etiología , Impedancia Eléctrica , Espectroscopía Dieléctrica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...