RESUMEN
The growing demand for wearable healthcare devices has led to an urgent need for cost-effective, wireless and portable breath monitoring systems. However, it is essential to explore novel nanomaterials that combine state-of-the-art flexible sensors with high performance and sensing capabilities along with scalability and industrially acceptable processing. In this study, we demonstrate a highly efficient NiS2-based flexible capacitive sensor fabricated via a solution-processible route using a novel single-source precursor [Ni{S2P(OPr)2}2]. The developed sensor could precisely detect the human respiration rate and exhibit rapid responsiveness, exceptional sensitivity and selectivity at ambient temperatures, with an ultra-fast response and recovery. The device effectively differentiates the exhaled breath patterns including slow, fast, oral and nasal breath, as well as post-exercise breath rates. Moreover, the sensor shows outstanding bending stability, repeatability, reliable and robust sensing performance and is capable of contactless sensing. The sensor was further employed with a user-friendly wireless interface to facilitate smartphone-enabled real-time breath monitoring systems. This work opens up numerous avenues for cost-effective, sustainable and versatile sensors with potential applications for Internet of Things-based flexible and wearable electronics.This article is part of the theme issue 'Celebrating the 15th anniversary of the Royal Society Newton International Fellowship'.
Asunto(s)
Nanoestructuras , Dispositivos Electrónicos Vestibles , Humanos , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Nanoestructuras/química , Níquel/química , Respiración , Frecuencia Respiratoria , Tecnología Inalámbrica/instrumentación , Pruebas Respiratorias/instrumentación , Pruebas Respiratorias/métodos , Diseño de Equipo , Teléfono Inteligente , Capacidad EléctricaRESUMEN
Exhaled breath electrochemical sensing is a promising biomedical technology owing to its portability, painlessness, cost-effectiveness, and user-friendliness. Here, we present a novel approach for target analysis in exhaled breath by integrating a comfortable paper-based collector into an N95 face mask, providing a universal solution for analyzing several biomarkers. As a model analyte, we detected SARS-CoV-2 spike protein from the exhaled breath by sampling the target analyte into the collector, followed by its detection out of the N95 face mask using a magnetic bead-based electrochemical immunosensor. This approach was designed to avoid any contact between humans and the chemicals. To simulate human exhaled breath, untreated saliva samples were nebulized on the paper collector, revealing a detection limit of 1 ng/mL and a wide linear range of 3.7-10,000 ng/mL. Additionally, the developed immunosensor exhibited high selectivity toward the SARS-CoV-2 spike protein, compared to other airborne microorganisms, and the SARS-CoV-2 nucleocapsid protein. Accuracy assessments were conducted by analyzing the simulated breath samples spiked with varying concentrations of SARS-CoV-2 spike protein, resulting in satisfactory recovery values (ranging from 97 ± 4 to 118 ± 1%). Finally, the paper-based hybrid immunosensor was successfully applied for the detection of SARS-CoV-2 in real human exhaled breath samples. The position of the collector in the N95 mask was evaluated as well as the ability of this paper-based analytical tool to identify the positive patient.
Asunto(s)
Técnicas Biosensibles , Pruebas Respiratorias , COVID-19 , Papel , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus , Humanos , SARS-CoV-2/inmunología , SARS-CoV-2/aislamiento & purificación , Pruebas Respiratorias/instrumentación , Pruebas Respiratorias/métodos , COVID-19/diagnóstico , COVID-19/virología , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Glicoproteína de la Espiga del Coronavirus/análisis , Glicoproteína de la Espiga del Coronavirus/inmunología , Inmunoensayo/instrumentación , Inmunoensayo/métodos , Límite de Detección , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Espiración , Respiradores N95 , Saliva/química , Saliva/virologíaRESUMEN
BACKGROUND: Increased smartphone ownership has led to the development of mobile smoking cessation programs. Although the related body of evidence, gathered through the conduct of randomized controlled trials (RCTs), has grown in quality and rigor, there is a need for longer-term data to assess associated smoking cessation durability. OBJECTIVE: The primary aim was to compare smoking cessation outcomes at 52 weeks in adult smokers randomized to a mobile smoking cessation program, Pivot (intervention), versus QuitGuide (control). The secondary aims included comparison of other smoking-related behaviors, outcomes and participant feedback, and exploratory analyses of baseline factors associated with smoking cessation. METHODS: In this remote pilot RCT, cigarette smokers in the United States were recruited on the web. Participants were offered 12 weeks of free nicotine replacement therapy (NRT). Data were self-reported via a web-based questionnaire with videoconference biovalidation in participants who reported 7-day point-prevalence abstinence (PPA). Outcomes focused on cessation rates with additional assessment of quit attempts, cigarettes per day (CPD), self-efficacy via the Smoking Abstinence Self-Efficacy Questionnaire, NRT use, and participant feedback. Cessation outcomes included self-reported 7- and 30-day PPA, abstinence from all tobacco products, and continuous abstinence. PPA and continuous abstinence were biovalidated using witnessed breath carbon monoxide samples. Exploratory post hoc regression analyses were performed to identify baseline variables associated with smoking cessation. RESULTS: Participants comprised 188 smokers (n=94, 50% in the Pivot group and n=94, 50% in the QuitGuide group; mean age 46.4, SD 9.2 years; n=104, 55.3% women; n=128, 68.1% White individuals; mean CPD 17.6, SD 9.0). Several cessation rates were higher in the Pivot group (intention to treat): self-reported continuous abstinence was 20% (19/94) versus 9% (8/94; P=.03) for QuitGuide, biochemically confirmed abstinence was 31% (29/94) versus 18% (17/94; P=.04) for QuitGuide, and biochemically confirmed continuous abstinence was 19% (18/94) versus 9% (8/94; P=.046) for QuitGuide. More Pivot participants (93/94, 99% vs 80/94, 85% in the QuitGuide group; P<.001) placed NRT orders (mean 3.3, SD 2.0 vs 1.8, SD 1.6 for QuitGuide; P<.001). Pivot participants had increased self-efficacy via the Smoking Abstinence Self-Efficacy Questionnaire (mean point increase 3.2, SD 7.8, P<.001 vs 1.0, SD 8.5, P=.26 for QuitGuide). QuitGuide participants made more mean quit attempts (7.0, SD 6.3 for Pivot vs 9.5, SD 7.5 for QuitGuide; P=.01). Among those who did not achieve abstinence, QuitGuide participants reported greater CPD reduction (mean -34.6%, SD 35.5% for Pivot vs -46.1%, SD 32.3% for QuitGuide; P=.04). Among those who reported abstinence, 90% (35/39) of Pivot participants and 90% (26/29) of QuitGuide participants indicated that their cessation program helped them quit. CONCLUSIONS: This pilot RCT supports the long-term effectiveness of the Pivot mobile smoking cessation program, with abstinence rates durable to 52 weeks. TRIAL REGISTRATION: ClinicalTrials.gov NCT04955639; https://clinicaltrials.gov/ct2/show/NCT04955639.
Asunto(s)
Cese del Hábito de Fumar , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Fumadores , Fumar , Dispositivos para Dejar de Fumar TabacoRESUMEN
Timely screening of lung cancer represents a challenging task for early diagnosis and treatment, which calls for reliable, low-cost, and noninvasive detection tools. One type of promising tools for early-stage cancer detection is breath analyzers or sensors that detect breath volatile organic compounds (VOCs) as biomarkers in exhaled breaths. However, a major challenge is the lack of effective integration of the different sensor system components toward the desired portability, sensitivity, selectivity, and durability for many of the current breath sensors. In this report, we demonstrate herein a portable and wireless breath sensor testing system integrated with sensor electronics, breath sampling, data processing, and sensor arrays derived from nanoparticle-structured chemiresistive sensing interfaces for detection of VOCs relevant to lung cancer biomarkers in human breaths. In addition to showing the sensor viability for the targeted application by theoretical simulations of chemiresistive sensor array responses to the simulated VOCs in human breaths, the sensor system was tested experimentally with different combinations of VOCs and human breath samples spiked with lung cancer-specific VOCs. The sensor array exhibits high sensitivity to lung cancer VOC biomarkers and mixtures, with a limit of detection as low as 6 ppb. The results from testing the sensor array system in detecting breath samples with simulated lung cancer VOC constituents have demonstrated an excellent recognition rate in discriminating healthy human breath samples and those with lung cancer VOCs. The recognition statistics were analyzed, showing the potential viability and optimization toward achieving the desired sensitivity, selectivity, and accuracy in the breath screening of lung cancer.
Asunto(s)
Neoplasias Pulmonares , Nanoestructuras , Compuestos Orgánicos Volátiles , Humanos , Neoplasias Pulmonares/diagnóstico , Biomarcadores de Tumor , Detección Precoz del Cáncer/métodosRESUMEN
A small and lightweight optical sensor head prototype with a disposable airway adapter for continuous mainstream monitoring of oxygen at high sampling rate is designed and tested on an optical benchtop. In terms of its size and functionality, the sensor head design is similar to current capnography systems from leading medical equipment manufacturers, and it has been designed within constraints of potential applications in direct breath oxygen monitoring that require direct interaction with the gas inside a breathing tube. The measurement precision of 0.1% O2with a 10 ms integration time are well within the performance required for breath O2monitoring applications.
Asunto(s)
Pruebas Respiratorias , Oxígeno , Humanos , Respiración , Capnografía , Rayos LáserRESUMEN
Ketones are well-known biomarkers of fat oxidation produced in the liver as a result of lipolysis. These biomarkers include acetoacetic acid and ß-hydroxybutyric acid in the blood/urine and acetone in our breath and skin. Monitoring ketone production in the body is essential for people who use caloric intake deficit to reduce body weight or use ketogenic diets for wellness or therapeutic treatments. Current methods to monitor ketones include urine dipsticks, capillary blood monitors, and breath analyzers. However, these existing methods have certain disadvantages that preclude them from being used more widely. In this work, we introduce a novel acetone sensor device that can detect acetone levels in breath and overcome the drawbacks of existing sensing approaches. The critical element of the device is a robust sensor with the capability to measure acetone using a complementary metal oxide semiconductor (CMOS) chip and convenient data analysis from a red, green, and blue deconvolution imaging approach. The acetone sensor device demonstrated sensitivity of detection in the micromolar-concentration range, selectivity for detection of acetone in breath, and a lifetime stability of at least one month. The sensor device utility was probed with real tests on breath samples using an established blood ketone reference method.
Asunto(s)
Acetona , Líquidos Corporales , Humanos , Cetonas , Ácido 3-Hidroxibutírico , BiomarcadoresRESUMEN
Silver nanoparticles of average size 12-13 nm were successfully decorated on the surface of multiwalled carbon nanotubes (MWCNTs) through a scalable wet chemical method without altering the structure of the MWCNTs. Employing this Ag@MWCNT, a multifunctional room-temperature curable conductive ink was developed, with PEDOT:PSS as the conductive binder. Screen printing of the ink could yield conductive planar traces with a 9.5 µm thickness and a conductivity of 28.99 S/cm, minimal surface roughness, and good adhesion on Mylar and Kapton. The versatility of the ink for developing functional elements for printed electronics was demonstrated by fabricating prototypes of a wearable strain sensor, a smart glove, a wearable heater, and a wearable breath sensor. The printed strain sensor exhibited a massive sensing range for wearable applications, including an impressive 1332% normalized resistance change under a maximum stretchability of 23% with superior cyclic stability up to 10â¯000 cycles. The sensor also exhibited an impeccable gauge factor of 142 for a 5% strain (59 for 23%). Furthermore, the sensor was integrated into a smart glove that could flawlessly replicate a human finger's gestures with a minimal response time of 225-370 ms. Piezoresistive vibration sensors were also fabricated by printing the ink on Mylar, which was employed to fabricate a smart mask and a smart wearable patch to monitor variations in human respiratory and pulmonary cycles. Finally, an energy-efficient flexible heater was fabricated using the developed ink. The heater could generate a uniform temperature distribution of 130 °C at the expense of only 393 mW/cm2 and require a minimum response time of 20 s. Thus, the unique formulation of Ag@MWCNT ink proved suitable for versatile devices for future wearable applications.
Asunto(s)
Nanopartículas del Metal , Nanotubos de Carbono , Dispositivos Electrónicos Vestibles , Humanos , Plata/química , Nanopartículas del Metal/química , TintaRESUMEN
BACKGROUND: Cigarette smoking remains the leading cause of preventable illness and death, underscoring ongoing need for evidence-based solutions. Pivot, a US Clinical Practice Guideline-based mobile smoking cessation program, comprises a personal carbon monoxide breath sensor; a smartphone app; in-app, text-based human-provided coaching; nicotine replacement therapy; and a moderated web-based community. Promising Pivot cohort studies have established the foundation for comparative assessment. OBJECTIVE: This study aimed to compare engagement, retention, attitudes toward quitting smoking, smoking behavior, and participant feedback between Pivot and QuitGuide, a US Clinical Practice Guideline-based smoking cessation smartphone app from the National Cancer Institute. METHODS: In this remote pilot randomized controlled trial, cigarette smokers in the United States were recruited on the web and randomized to Pivot or QuitGuide. Participants were offered 12 weeks of free nicotine replacement therapy. Data were self-reported via weekly web-based questionnaires for 12 weeks and at 26 weeks. Outcomes included engagement and retention, attitudes toward quitting smoking, smoking behavior, and participant feedback. The primary outcome was self-reported app openings at 12 weeks. Cessation outcomes included self-reported 7- and 30-day point prevalence abstinence (PPA), abstinence from all tobacco products, and continuous abstinence at 12 and 26 weeks. PPA and continuous abstinence were biovalidated via breath carbon monoxide samples. RESULTS: Participants comprised 188 smokers (94 Pivot and 94 QuitGuide): mean age 46.4 (SD 9.2) years, 104 (55.3%) women, 128 (68.1%) White individuals, and mean cigarettes per day 17.6 (SD 9.0). Engagement via mean "total app openings through 12 weeks" (primary outcome) was Pivot, 157.9 (SD 210.6) versus QuitGuide, 86.5 (SD 66.3; P<.001). Self-reported 7-day PPA at 12 and 26 weeks was Pivot, 35% (33/94) versus QuitGuide, 28% (26/94; intention to treat [ITT]: P=.28) and Pivot, 36% (34/94) versus QuitGuide, 27% (25/94; ITT: P=.12), respectively. Self-reported 30-day PPA at 12 and 26 weeks was Pivot, 29% (27/94) versus QuitGuide, 22% (21/94; ITT: P=.32) and Pivot, 32% (30/94) versus QuitGuide, 22% (21/94; ITT: P=.12), respectively. The biovalidated abstinence rate at 12 weeks was Pivot, 29% (27/94) versus QuitGuide, 13% (12/94; ITT: P=.008). Biovalidated continuous abstinence at 26 weeks was Pivot, 21% (20/94) versus QuitGuide, 10% (9/94; ITT: P=.03). Participant feedback, including ease of setup, impact on smoking, and likelihood of program recommendation were favorable for Pivot. CONCLUSIONS: In this randomized controlled trial comparing the app-based smoking cessation programs Pivot and QuitGuide, Pivot participants had higher engagement and biovalidated cessation rates and more favorable user feedback at 12 and 26 weeks. These findings support Pivot as an effective, durable mobile smoking cessation program. TRIAL REGISTRATION: ClinicalTrials.gov NCT04955639; https://clinicaltrials.gov/ct2/show/NCT04955639.
Asunto(s)
Cese del Hábito de Fumar , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Fumadores , Dispositivos para Dejar de Fumar Tabaco , Monóxido de Carbono , Proyectos PilotoRESUMEN
A breath sensor for real-time measurement of human exhaled carbon monoxide is reported. This breath sensor is based on a novel photoacoustic heterodyne gas sensing technique, which combines the conventional photoacoustic spectroscopy with the beat-frequency detection algorithm, thus offering a fast response time and a convenient optical alignment, as well as eliminating the needs for frequency calibration and wavelength locking. The principle of photoacoustic heterodyne gas sensing was explained in detail. The performance of the photoacoustic heterodyne breath sensor was evaluated in terms of minimum detection limit, response time, and linearity. The exhaled carbon monoxide levels of eight volunteers were measured and the results demonstrate the reliability and feasibility of this breath sensor.
RESUMEN
The paper presents a wearable sensor for breath and pulse monitoring using an inertial sensor and episodic broadcast radio transmission. The data transmission control algorithm applied allows for the transmission of additional information using the standard PDU format and, at the same time, goes beyond the Bluetooth teletransmission standard (BLE). The episodic broadcast transmission makes it possible to receive information from sensors without the need to create a dedicated radio link or a defined network structure. The radio transmission controlled by the occurrence of a specific event in the monitored signal is combined with the reference wire transmission. The signals from two different types of sensors and the simulated ECG signal are used to control the BLE transmission. The presented results of laboratory tests indicate the effectiveness of episodic data transmission in the BLE standard. The conducted analysis showed that the mean difference in pulse detection using the episodic transmission compared to the wire transmission is 0.038 s, which is about 4% of the mean duration of a single cycle, assuming that the average adult human pulse is 60 BPM.
Asunto(s)
Algoritmos , Respiración , Adulto , Frecuencia Cardíaca/fisiología , Humanos , Monitoreo Fisiológico/métodosRESUMEN
Respiration rate is an essential vital sign that requires monitoring under various conditions, including in strong electromagnetic environments such as in magnetic resonance imaging systems. To provide an electromagnetically-immune breath-sensing system, we propose an all-fiber-optic wearable breath sensor based on a fiber-tip microcantilever. The microcantilever was fabricated on a fiber-tip by two-photon polymerization microfabrication based on femtosecond laser, so that a micro Fabry-Pérot (FP) interferometer was formed between the microcantilever and the end-face of the fiber. The cavity length of the micro FP interferometer was reduced as a result of the bending of the microcantilever induced by breath airflow. The signal of breath rate was rebuilt by detecting power variations of the FP interferometer reflected light and applying dynamic thresholds. The breath sensor achieved a high sensitivity of 0.8 nm/(m/s) by detecting the reflection spectrum upon applied flow velocities from 0.53 to 5.31 m/s. This sensor was also shown to have excellent thermal stability as its cross-sensitivity of airflow with respect to the temperature response was only 0.095 (m/s)/°C. When mounted inside a wearable surgical mask, the sensor demonstrated the capability to detect various breath patterns, including normal, fast, random, and deep breaths. We anticipate the proposed wearable breath sensor could be a useful and reliable tool for respiration rate monitoring.
Asunto(s)
Tecnología de Fibra Óptica , Dispositivos Electrónicos Vestibles , Rayos Láser , Fibras Ópticas , TemperaturaRESUMEN
With the global population prevalence of diabetes surpassing 463 million cases in 2019 and diabetes leading to millions of deaths each year, there is a critical need for feasible, rapid, and non-invasive methodologies for continuous blood glucose monitoring in contrast to the current procedures that are either invasive, complicated, or expensive. Breath analysis is a viable methodology for non-invasive diabetes management owing to its potential for multiple disease diagnoses, the nominal requirement of sample processing, and immense sample accessibility; however, the development of functional commercial sensors is challenging due to the low concentration of volatile organic compounds (VOCs) present in exhaled breath and the confounding factors influencing the exhaled breath profile. Given the complexity of the topic and the skyrocketing spread of diabetes, a multifarious review of exhaled breath analysis for diabetes monitoring is essential to track the technological progress in the field and comprehend the obstacles in developing a breath analysis-based diabetes management system. In this review, we consolidate the relevance of exhaled breath analysis through a critical assessment of current technologies and recent advancements in sensing methods to address the shortcomings associated with blood glucose monitoring. We provide a detailed assessment of the intricacies involved in the development of non-invasive diabetes monitoring devices. In addition, we spotlight the need to consider breath biomarker clusters as opposed to standalone biomarkers for the clinical applicability of exhaled breath monitoring. We present potential VOC clusters suitable for diabetes management and highlight the recent buildout of breath sensing methodologies, focusing on novel sensing materials and transduction mechanisms. Finally, we portray a multifaceted comparison of exhaled breath analysis for diabetes monitoring and highlight remaining challenges on the path to realizing breath analysis as a non-invasive healthcare approach.
Asunto(s)
Pruebas Respiratorias , Diabetes Mellitus , Compuestos Orgánicos Volátiles , Biomarcadores , Diabetes Mellitus/diagnóstico , Espiración , Humanos , Compuestos Orgánicos Volátiles/análisisRESUMEN
Noble metal additives are widely used to improve the performance of metal oxide gas sensors, most prominently with palladium on tin oxide. Here, we photodeposit different quantities of Pd (0-3 mol%) onto nanostructured SnO2 and determine their effect on sensing acetone, a critical tracer of lipolysis by breath analysis. We focus on understanding the effect of operating temperature on acetone sensing performance (sensitivity and response/recovery times) and its relationship to catalytic oxidation of acetone through a packed bed of such Pd-loaded SnO2. The addition of Pd can either boost or deteriorate the sensing performance, depending on its loading and operating temperature. The sensor performance is optimal at Pd loadings of less than 0.2 mol% and operating temperatures of 200-262.5 °C, where acetone conversion is around 50%.
RESUMEN
BACKGROUND: Despite decreasing prevalence over the last several decades, cigarette smoking remains the leading cause of preventable death and disease, underscoring the need for innovative, effective solutions. Pivot is a novel, inclusive smoking cessation program designed for smokers along the entire spectrum of readiness to quit. Pivot leverages proven methods and technological advancements, including a personal portable breath carbon monoxide sensor, smartphone app, and in-app text-based coaching. We previously reported outcomes from the end of active Pivot program participation in 319 adult smokers. Herein, we report longer-term follow up in this cohort. OBJECTIVE: The aim of this study was to assess and report participant outcomes 3 months after completion of Pivot, including smoking behavior, quit rates, continuous abstinence rates and durability, and predictors of abstinence. METHODS: This prospective remote cohort study included US-based cigarette smokers aged 18 to 65 years who smoked ≥5 cigarettes per day (CPD). Three months after completion of active participation in Pivot, final follow-up data were collected via an online questionnaire. Outcomes included smoking behavior (CPD and quit attempts), self-reported quit rates (7- and 30-day point prevalence abstinence [PPA]), and continuous abstinence rates (proportion who achieved uninterrupted abstinence) and duration. Exploratory regression analyses were performed to identify baseline characteristics associated with achievement of 7-day PPA, 30-day PPA, and continuous abstinence. RESULTS: A total of 319 participants completed onboarding (intention-to-treat [ITT]); 288/319 participants (90.3%) completed follow up (completers) at a mean of 7.2 (SD 1.2) months after onboarding. At final follow up, CPD were reduced by 52.6% (SE 2.1; P<.001) among all 319 participants, and most completers (152/288, 52.8%) reduced their CPD by at least 50%. Overall, most completers (232/288, 80.6%) made at least one quit attempt. Quit rates increased after the end of Pivot; using ITT analyses, 35.4% (113/319) achieved 7-day PPA and 31.3% (100/319) achieved 30-day PPA at final follow up compared with 32.0% (102/319) and 27.6% (88/319), respectively, at the end of the Pivot program. Continuous abstinence was achieved in about a quarter of those who onboarded (76/319, 23.8%) and in most who reported 30-day PPA at the end of Pivot (76/88, 86.4%), with a mean abstinence duration of 5.8 (SD 0.6) months. In exploratory regression analyses, lower baseline CPD, more positive baseline attitudes reflecting higher self-efficacy (higher confidence to quit and lower perceived difficulty of quitting), and higher education were associated with achieving abstinence. CONCLUSIONS: This study provides the first longer-term outcomes of the Pivot smoking cessation program. At final follow up, quit rates increased and continuous abstinence was favorable; the majority who achieved abstinence at the end of Pivot sustained abstinence throughout follow up. Decreases in CPD persisted and most participants made a quit attempt. Overall, final follow-up outcomes were stable or improved when compared to previous outcomes from the end of the program. These findings validate earlier results, and suggest that Pivot is an effective and durable solution for smoking cessation. TRIAL REGISTRATION: ClinicalTrials.gov NCT03295643; https://clinicaltrials.gov/ct2/show/NCT03295643.
Asunto(s)
Pruebas Respiratorias/métodos , Tutoría/métodos , Aplicaciones Móviles/tendencias , Cese del Hábito de Fumar/métodos , Fumar/tendencias , Adolescente , Adulto , Anciano , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Autoinforme , Encuestas y Cuestionarios , Adulto JovenRESUMEN
Accurate measurement and monitoring of respiration is vital in patients affected by severe acute respiratory syndrome coronavirus - 2 (SARS-CoV-2). Patients with severe chronic diseases and pneumonia need continuous respiration monitoring and oxygenation support. Existing respiratory sensing techniques require direct contact with the human body along with expensive and heavy Holter monitors for continuous real-time monitoring. In this work, we propose a low-cost, non-invasive and reliable paper-based wearable screen printed sensor for human respiration monitoring as an effective alternative of existing sensing systems. The proposed sensor was fabricated using traditional screen printing of multi-walled carbon nanotubes (MWCNTs) and polydimethylsiloxane (PDMS) composite based interdigitated electrodes on paper substrate. The paper substrate was used as humidity sensing material of the sensor. The hygroscopic nature of paper during inhalation and exhalation causes a change in dielectric constant, which in turn changes the capacitance of the sensor. The composite interdigitated electrode configuration exhibited better response times with a rise time of 1.178s being recorded during exhalation and fall time of 0.88s during inhalation periods. The respiration rate of sensor was successfully examined under various breathing conditions such as normal breathing, deep breathing, workout, oral breathing, nasal breathing, fast breathing and slow breathing by employing it in a wearable mask, a mandatory wearable product during the current COVID-19 pandemic situation.Thus, the above proposed sensor may hold tremendous potential in wearable/flexible healthcare technology with good sensitivity, stability, biodegradability and flexibility at this time of need.
RESUMEN
We developed a simple methodology to fabricate an Ni/NiOx-based flexible breath sensor by a single-step laser digital patterning process of solution-processed NiOx thin-film deposited using NiOx nanoparticle ink. Laser-induced reductive sintering phenomenon enables for the generation of three parts of Ni electrodes and two narrow NiOx-sensing channels in between, defined on a single layer on a thin flexible polymer substrate. The Ni/NiOx-based breath sensor efficiently detects human breath at a relatively low operating temperature (50 °C) with fast response/recovery times (1.4 s/1.7 s) and excellent repeatability. The mechanism of the gas-sensing ability enhancement of the sensor was investigated by X-ray photoelectron spectroscopy analysis. Furthermore, by decoupling of the temperature effect from the breathing gas, the response of the sensor due to the temperature alone and due to the chemical components in the breathing gas could be separately evaluated. Finally, bending and cyclic bending tests (10,000 cycles) demonstrated the superior mechanical stability of the flexible breath sensor.
RESUMEN
BACKGROUND: Tobacco use is the leading cause of preventable morbidity and mortality. Existing evidence-based treatments are underutilized and have seen little recent innovation. The success of personal biofeedback interventions in other disease states portends a similar opportunity in smoking cessation. The Pivot Breath Sensor is a personal interactive FDA-cleared (over-the-counter) device that measures carbon monoxide (CO) in exhaled breath, enabling users to link their smoking behavior and CO values, and track their progress in reducing or quitting smoking. OBJECTIVE: The objective of this study is to assess the Pivot Breath Sensor in people who smoke cigarettes, evaluating changes in attitudes toward quitting smoking, changes in smoking behavior, and use experience. METHODS: US adults (18-80 years of age, ≥10 cigarettes per day [CPD]) were recruited online for this remote 12-week study. Participants completed a screening call, informed consent, and baseline questionnaire, and then were mailed their sensor. Participants were asked to submit 4 or more breath samples per day and complete questionnaires at 1-4, 8, and 12 weeks. Outcomes included attitudes toward quitting smoking (Stage of Change, success to quit, and perceived difficulty of quitting), smoking behavior (quit attempts, CPD reduction, and 7-, 30-day point prevalence abstinence [PPA]), and use experience (impact and learning). RESULTS: Participants comprised 234 smokers, mean age 39.9 (SD 11.3) years, 52.6% (123/234) female, mean CPD 20.3 (SD 8.0). The 4- and 12-week questionnaires were completed by 92.3% (216/234) and 91.9% (215/234) of participants, respectively. Concerning attitude outcomes, at baseline, 15.4% (36/234) were seriously thinking of quitting in the next 30 days, increasing to 38.9% (84/216) at 4 weeks and 47.9% (103/215) at 12 weeks (both P<.001). At 12 weeks, motivation to quit was increased in 39.1% (84/215), unchanged in 54.9% (118/215), and decreased in 6.0% (13/215; P<.001). Additional attitudes toward quitting improved from baseline to 12 weeks: success to quit 3.3 versus 5.0 (P<.001) and difficulty of quitting 2.8 versus 4.3 (P<.001). Regarding smoking behavior, at 4 weeks, 28.2% (66/234) had made 1 or more quit attempts (≥1 day of abstinence), increasing to 48.3% (113/234) at 12 weeks. At 4 weeks, 23.1% (54/234) had reduced CPD by 50% or more, increasing to 38.5% (90/234) at 12 weeks. At 12 weeks, CPD decreased by 41.1% from baseline (P<.001), and 7- and 30-day PPA were 12.0% (28/234) and 6.0% (14/234), respectively. Concerning use experience, 75.3% (171/227) reported the sensor increased their motivation to quit. More than 90% (>196/214) indicated the sensor taught them about their CO levels and smoking behavior, and 73.1% (166/227) reported that seeing their CO values made them want to quit smoking. CONCLUSIONS: Use of the Pivot Breath Sensor resulted in a significant increase in motivation to quit, a reduction in CPD, and favorable quit attempt rates. These outcomes confer increased likelihood of quitting smoking. Accordingly, the results support a role for biofeedback via personal CO breath sampling in smoking cessation. TRIAL REGISTRATION: ClinicalTrials.gov NCT04133064; https://clinicaltrials.gov/ct2/show/NCT04133064.
Asunto(s)
Pruebas Respiratorias/instrumentación , Monóxido de Carbono/química , Humo/análisis , Fumar/patología , Fumar Tabaco/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto JovenRESUMEN
Bimodally meso- (2-50 nm) and macroporous (>50 nm) WO3 microbelts (MBs) functionalized with sub-3 nm Pt catalysts were fabricated via the electrospinning technique followed by subsequent calcination. Importantly, apoferritin (Apo), tea saponin and polystyrene colloid spheres (750 nm) dispersed in an electrospinning solution acted as forming agents for producing meso- and macropores on WO3 MBs during calcination. Particularly, mesopores provide not only numerous reaction sites for effective chemical reactions, but also facilitate gas diffusion into the interior of the WO3 MBs, dominated by Knudsen diffusion. The macropores further accelerate gas permeability in the interior and on the exterior of the WO3 MBs. In addition, Pt nanoparticles with mean diameters of 2.27 nm were synthesized by using biological protein cages, such as Apo, to further enhance the gas sensing performance. Bimodally porous WO3 MBs functionalized by Pt catalysts showed remarkably high hydrogen sulfide (H2S) response ( Rair/ Rgas = 61 @ 1 ppm) and superior selectivity to H2S against other interfering gases, such as acetone (CH3COCH3), ethanol (C2H5OH), ammonia (NH3), and carbon monoxide (CO). These results demonstrate a high potential for the feasibility of catalyst-loaded meso- and macroporous WO3 MBs as new sensing platforms for the possibility of real-time diagnosis of halitosis.
RESUMEN
Exhaled breath is a body secretion, and the sampling process of this is simple and cost effective. It can be non-invasively collected for diagnostic procedures. Variations in the chemical composition of exhaled breath resulting from gaseous exchange in the extensive capillary network of the body are proposed to be associated with pathophysiological changes. In light of the foreseeable potential of exhaled breath as a diagnostic specimen, we used gas chromatography and mass spectrometry (GC-MS) to study the chemical compounds present in exhaled breath samples from patients with Alzheimer's disease (AD), Parkinson's disease (PD), and from healthy individuals as a control group. In addition, we also designed and developed a chemical-based exhaled breath sensor system to examine the distribution pattern in the patient and control groups. The results of our study showed that several chemical compounds, such as 1-phenantherol and ethyl 3-cyano-2,3-bis (2,5,-dimethyl-3-thienyl)-acrylate, had a higher percentage area in the AD group than in the PD and control groups. These results may indicate an association of these chemical components in exhaled breath with the progression of disease. In addition, in-house fabricated exhaled breath sensor systems, containing several types of gas sensors, showed significant differences in terms of the normalized response of the sensitivity characteristics between the patient and control groups. A subsequent clustering analysis was able to distinguish between the AD patients, PD patients, and healthy individuals using principal component analysis, Sammon's mapping, and a combination of both methods, in particular when using the exhaled breath sensor array system A consisting of eight sensors. With this in mind, the exhaled breath sensor system could provide alternative option for diagnosis and be applied as a useful, effective tool for the screening and diagnosis of AD in the near future.
Asunto(s)
Espiración , Enfermedad de Alzheimer , Pruebas Respiratorias , Cromatografía de Gases y Espectrometría de Masas , Humanos , Enfermedad de Parkinson , Compuestos Orgánicos VolátilesRESUMEN
Room-temperature (RT) operation sensors are constantly in increasing demand because of their low power consumption, simple operation, and long lifetime. However, critical challenges such as low sensing performance, vulnerability under highly humid state, and poor recyclability hinder their commercialization. In this work, sub-10 nm hollow, bimetallic Pt-Ag nanoparticles (NPs) were successfully formed by galvanic replacement reaction in bioinspired hollow protein templates and sensitized on the multidimensional SnO2-WO3 heterojunction nanofibers (HNFs). Formation of hollow, bimetallic NPs resulted in the double-side catalytic effect, rendering both surface and inner side chemical reactions. Subsequently, SnO2-WO3 HNFs were synthesized by incorporating 2D WO3 nanosheets (NSs) with 0D SnO2 sphere by c-axis growth inhibition effect and fluid dynamics of liquid Sn during calcination. Hierarchically assembled HNFs effectively modulate surface depletion layer of 2D WO3 NSs by electron transfers from WO3 to SnO2 stemming from creation of heterojunction. Careful combination of bimetallic catalyst NPs with HNFs provided an extreme recyclability under exhaled breath (95 RH%) with outstanding H2S sensitivity. Such sensing platform clearly distinguished between the breath of healthy people and simulated halitosis patients.