Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39099249

RESUMEN

BACKGROUND: Although radiofrequency ablation of the cavotricuspid isthmus (CTI), responsible for sustaining atrial flutter, is a highly effective procedure, in extended patients' observations following this procedure, more than every tenth becomes unsuccessful. Therefore, this study aimed to provide helpful information about the anatomy of the CTI in transthoracic echocardiography, which can aid in better planning of the CTI radiofrequency ablation in patients with typical atrial flutter. MATERIALS AND METHODS: 56 patients with typical atrial flutter after radiofrequency ablation were evaluated at the end of the 24-month observation period. With substernal modified transthoracic echocardiographic (mTTE) evaluation, we identified four main anatomical obstacles impeding radiofrequency ablation. These obstacles were tricuspid annular plane systolic excursion, cavotricuspid isthmus length, cavotricuspid isthmus morphology, and the presence of a prominent Eustachian ridge/Eustachian valve. All intraprocedural radiofrequency ablation data were collected for analysis and correlated with anatomical data. RESULTS: In the 24-month observation period, freedom from atrial flutter was 67.86%. The mean length of the isthmus was 30.34 ± 6.67 mm. The isthmus morphology in 56 patients was categorized as flat (n = 27; 48.2%), concave (n = 10; 17.85%), and pouch (n = 19, 33.9%). A prominent Eustachian ridge was observed in 23 patients (41.1%). Lack of anatomical obstacles in mTTE evaluation resulted in 100% efficacy, while the presence of at least two obstacles significantly increased the risk of unsuccessful ablation with more than two (OR 12.31 p = 0.01). Generally, 8 mm electrodes were the most effective for non-difficult CTI, while 3.5 mm electrodes used with a 3D system had highest performance for complex CTI. Notably, aging was the only factor that worsened the long-term outcome (OR 1.07 p = 0.044). CONCLUSIONS: Preoperative usage of mTTE evaluation helps predict difficulty in cavotricuspid isthmus radiofrequency ablation, thus allowing better planning of the radiofrequency ablation strategy using the most accurate radiofrequency ablation electrode.

2.
Herz ; 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39138662

RESUMEN

BACKGROUND: Atrial flutter (AFL) and atrial fibrillation (AF) are the most commonly detected supraventricular arrhythmias and share similar pathophysiological mechanisms. After the successful ablation of AFL, AF frequently occurs in the long-term follow-up. As emphasized in some studies, certain mechanisms seem to predispose to the development of AF in AFL patients, and approximately 20% of these patients have accompanying AFL. PURPOSE: We aimed to analyze independent risk factors that predict the development of AF in patients who underwent typical AFL ablation. METHODS: This was a multicenter, cross-sectional, and retrospective study. A total of 442 patients who underwent typical AFL ablation at three different centers between January 1, 2018 and January 1, 2022 were included retrospectively. After the ablation procedure the patients were divided into those who developed AF and those who did not. The patients were followed up for an average of 12 (4-20) months. In the post-procedural period, atrial arrhythmias were investigated with 24­h Holter and ECG at 1 month, 6 months, and 12 months and then at 6­month intervals thereafter. RESULTS: Overall, AF developed in 206 (46.6%) patients in the long-term follow-up. Age, hypertension (HT), obstructive sleep apnea syndrome (OSAS), previous cerebrovascular accident (CVA), left atrium anteroposterior diameter, severe mitral regurgitation, hemoglobin, blood glucose, and HbA1c values were found to be significant in univariable analysis. According to multivariable analysis, HT (p = 0.014; HR: 1.483 [1.084-2.030]), OSAS (p = 0.008; HR: 1.520 [1.117-2.068]) and previous CVA (p = 0.038; HR: 1.749 [1.031-2.968]) were independently associated with the development of AF in AFL patients who underwent ablation procedure. CONCLUSION: In the present study, we found that HT, OSAS, and previous CVA were independently correlated with the development of AF in the long-term follow-up of patients who underwent typical AFL ablation. We consider that AFL patients with such risk factors should be followed up closely following cavotricuspid isthmus ablation for the development of AF.

3.
Rev Cardiovasc Med ; 25(1): 11, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39077671

RESUMEN

The demonstration of a peritricuspid circular movement with a zone of slow conduction in the cavotricuspid isthmus, together with the high efficacy of linear ablation and widely accepted acute endpoints, has established typical flutter as a disease with a well-defined physiopathology and treatment. However, certain aspects regarding its deeper physiopathology, ablation targets, and methods for verifying the results remain to be clarified. While current research efforts have primarily been focused on the advancement of effective ablation techniques, it is crucial to continue exploring the intricate electrophysiological, ultrastructural, and pharmacological pathways that underlie the development of atrial flutter. This ongoing investigation is essential for the development of targeted preventive strategies that can act upon the specific mechanisms responsible for the initiation and maintenance of this arrhythmia. In this work, we will discuss less ascertained aspects alongside the most widely recognized general data, as well as the most recent or less commonly used contributions regarding the electrophysiological evaluation and ablation of typical atrial flutter. Regarding electrophysiological characteristics, one of the most intriguing findings is the presence of low voltage zones in some of these patients together with the presence of a functional, unidirectional line of block between the two vena cava. It is theorized that episodes of paroxysmal atrial fibrillation can trigger this line of block, which may then allow the onset of stable atrial flutter. Without this, the patient will either remain in atrial fibrillation or return to sinus rhythm. Another of the most important pending tasks is identifying patients at risk of developing post-ablation atrial fibrillation. Discriminating between individuals who will experience a complete arrhythmia cure and those who will develop atrial fibrillation after flutter ablation, remains essential given the important prognostic and therapeutic implications. From the initial X-ray guided linear cavotricuspid ablation, several alternatives have arisen in the last decade: electrophysiological criteria-directed point applications based on entrainment mapping, applications directed by maximum voltage criteria or by wavefront speed and maximum voltage criteria (omnipolar mapping). Electro-anatomical navigation systems offer substantial support in all three strategies. Finally, the electrophysiological techniques to confirm the success of the procedure are reviewed.

5.
JACC Clin Electrophysiol ; 10(5): 885-896, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38385916

RESUMEN

BACKGROUND: In treating atrial fibrillation, pulsed-field ablation (PFA) has comparable efficacy to conventional thermal ablation, but with important safety advantages: no esophageal injury or pulmonary vein stenosis, and rare phrenic nerve injury. However, when PFA is delivered in proximity to coronary arteries using a pentaspline catheter, which generates a broad electrical field, severe vasospasm can be provoked. OBJECTIVES: The authors sought to study the vasospastic potential of a focal PFA catheter with a narrower electrical field and develop a preventive strategy with nitroglycerin. METHODS: During atrial fibrillation ablation, a focal PFA catheter was used for cavotricuspid isthmus ablation. Angiography of the right coronary artery (some with fractional flow reserve measurement) was performed before, during, and after PFA. Beyond no nitroglycerin (n = 5), and a few testing strategies (n = 8), 2 primary nitroglycerin administration strategies were studied: 1) multiple boluses (3-2 mg every 2 min) into the right atrium (n = 10), and 2) a bolus (3 mg) into the right atrium with continuous peripheral intravenous infusion (1 mg/min; n = 10). RESULTS: Without nitroglycerin, cavotricuspid isthmus ablation provoked moderate-severe vasospasm in 4 of 5 (80%) patients (fractional flow reserve 0.71 ± 0.08). With repetitive nitroglycerin boluses, severe spasm did not occur, and mild-moderate vasospasm occurred in only 2 of 10 (20%). Using the bolus + infusion strategy, severe and mild-moderate spasm occurred in 1 and 3 of 10 patients (aggregate 40%). No patient had ST-segment changes. CONCLUSIONS: Ablation of the cavotricuspid isthmus using a focal PFA catheter routinely provokes right coronary vasospasm. Pretreatment with high doses of parenteral nitroglycerin prevents severe spasm.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Vasoespasmo Coronario , Nitroglicerina , Humanos , Fibrilación Atrial/cirugía , Nitroglicerina/administración & dosificación , Nitroglicerina/uso terapéutico , Vasoespasmo Coronario/prevención & control , Masculino , Persona de Mediana Edad , Femenino , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Anciano , Vasodilatadores/uso terapéutico , Vasodilatadores/administración & dosificación , Angiografía Coronaria , Vasos Coronarios/efectos de los fármacos , Vasos Coronarios/cirugía , Vasos Coronarios/fisiopatología
6.
J Arrhythm ; 40(1): 191-194, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38333391

RESUMEN

Background: Electroanatomical mapping is an essential tool in the ablation of typical AFL. Objectives: To identify the existence of voltage patterns in the CTI voltage maps and their relevance for typical AFL ablation. Methods: A voltage map of the CTI was made prior to ablation, identifying the areas of maximum voltage and their location along the CTI, allowing classification into patterns according to their distribution. A stepwise ablation approach targeting the areas of maximum voltage was conducted. The ablation characteristics were compared based on the pattern obtained. Results: Two voltage patterns were identified, with differences in ablation time to bidirectional CTI block. No complications occurred. Conclusions: Voltage mapping identifies patterns in the CTI with implications for typical AFL ablation.

7.
Heart Rhythm ; 21(2): 133-140, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37956774

RESUMEN

BACKGROUND: In arrhythmogenic right ventricular cardiomyopathy (ARVC), risk of atrial arrhythmias (AAs) persists after ventricular tachycardia (VT) ablation. OBJECTIVE: The purpose of this study was to determine the type, prevalence, outcome, and risk correlates of AA in ARVC in patients undergoing VT ablation. METHODS: Prospectively collected procedural and clinical data on ARVC patients undergoing VT ablation were analyzed. Risk score for typical atrial flutter was determined from univariate logistic regression analysis. RESULTS: Of 119 consecutive patients with ARVC and VT ablation, 40 (34%) had AA: atrial fibrillation (AF) in 31, typical isthmus-dependent atrial flutter (AFL) in 27, and atrial tachycardia/atypical flutter (AT) in 10. Seventeen patients (43%) with AA experienced inappropriate defibrillator therapy, with 15 patients experiencing shocks. Ablation was performed for typical AFL in 21 (53%), AT in 5 (13%), and pulmonary vein isolation for AF in 4 (10%) patients and prevented AA in 78% and all AFL during additional mean follow-up of 65 months. Risk score for typical flutter included age >40 years (1 point), ≥moderate right ventricular dysfunction (2 points), ≥moderate tricuspid regurgitation (2 points), ≥moderate right atrial dilation (2 points), and right ventricular volume >250 cc (3points), with score >4 identifying 50% prevalence of typical flutter. CONCLUSION: AAs are common in patients with ARVC and VT, can result in inappropriate implantable cardioverter-defibrillator shocks, and typically are controlled with atrial ablation. A risk score can be used to identify patients at high risk for typical AFL who may be considered for isthmus ablation at the time of VT ablation.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Adulto , Aleteo Atrial/complicaciones , Aleteo Atrial/diagnóstico , Displasia Ventricular Derecha Arritmogénica/complicaciones , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/etiología , Taquicardia Supraventricular/cirugía , Complicaciones Posoperatorias/etiología , Ablación por Catéter/efectos adversos , Resultado del Tratamiento
9.
J Clin Med ; 12(21)2023 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-37959380

RESUMEN

BACKGROUND: The best ablation treatment for persistent atrial fibrillation (PeAF) patients is still debated. The vein of Marshall (VOM) seems to be a promising target for ablation and could be combined with a linear set of ablation lesions. The aim of our study is to evaluate the incidence of AF recurrences in a PeAF population treated with a comprehensive ablation approach consisting of VOM ethanol infusion (EI), pulmonary vein isolation (PVI), a left atrial (LA) roofline, a mitral line (guided by the newly formed lesion after alcohol infusion into the VOM and validated by pacing), and a cavotricuspid isthmus line. METHODS: Consecutive patients undergoing the first ablation procedure of catheter ablation (CA) for PeAF were enrolled. All patients underwent VOM-EI, PVI, and ablation lines along the roof of the LA, mitral, and cavotricuspid isthmus. LA voltage mapping before and after VOM-EI was also performed. An implantable loop recorder (ILR) was implanted at the end of the ablation in each patient. RESULTS: Thirty-one consecutive patients (66 ± 8 years and 71% male) affected by PeAF were included in this study. The VOM-EI procedural phase lasted 21.4 ± 10.1 min. PV isolation and lines were validated in all subjects. The ML block was achieved within 10.8 ± 8.7 min. At a mean follow-up of 12 ± 7 months, 27 out of 31 (87%) patients remained free from AT/AF recurrences. Among the patients with recurrences, two (50%) had incomplete ablation lesions and three (75%) had "suboptimal" VOM-EI. In 23/31 patients (74%), antiarrhythmic drugs (AADs) were discontinued after 1 month of follow-up. No significant complications were reported during the follow-up. CONCLUSIONS: this single-center experience demonstrates that VOM-EI systematically combined with an anatomical ablation set in patients with PeAF resulted in feasible, safe, and effective freedom from AF/AT recurrences in 87% of the population after a 1-year follow-up period according to an ILR.

10.
World J Cardiol ; 15(9): 415-426, 2023 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-37900261

RESUMEN

Cardiac magnetic resonance (CMR) imaging could enable major advantages when guiding in real-time cardiac electrophysiology procedures offering high-resolution anatomy, arrhythmia substrate, and ablation lesion visualization in the absence of ionizing radiation. Over the last decade, technologies and platforms for performing electrophysiology procedures in a CMR environment have been developed. However, performing procedures outside the conventional fluoroscopic laboratory posed technical, practical and safety concerns. The development of magnetic resonance imaging compatible ablation systems, the recording of high-quality electrograms despite significant electromagnetic interference and reliable methods for catheter visualization and lesion assessment are the main limiting factors. The first human reports, in order to establish a procedural workflow, have rationally focused on the relatively simple typical atrial flutter ablation and have shown that CMR-guided cavotricuspid isthmus ablation represents a valid alternative to conventional ablation. Potential expansion to other more complex arrhythmias, especially ventricular tachycardia and atrial fibrillation, would be of essential impact, taking into consideration the widespread use of substrate-based strategies. Importantly, all limitations need to be solved before application of CMR-guided ablation in a broad clinical setting.

11.
Front Cardiovasc Med ; 10: 1244137, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37900565

RESUMEN

Introduction: Catheter ablation is the preferred treatment for typical atrial flutter (AFl), but it can be challenging due to anatomical abnormalities. The use of 3D electroanatomical mapping systems (EAMS) has reduced fluoroscopy exposure during AFl ablation. Intracardiac echocardiography (ICE) has also shown benefits in reducing radiation exposure during AFl ablation. However, there is a lack of evidence on the feasibility of ICE-guided, zero-fluoroscopy AFl ablation without the use of EAMS. Methods: In this prospective study, we enrolled 80 patients with CTI-dependent AFl. The first 40 patients underwent standard fluoroscopy + ICE-guided ablation (Standard ICE group), while the other 40 patients underwent zero-fluoroscopy ablation using only ICE (Zero ICE group). Procedure outcomes, including acute success, procedure time, fluoroscopy time, radiation dose, and complications, were compared between the groups. Results: The acute success rate was 100% in both groups. Out of the 40 cases, the zero-fluoroscopy strategy was successfully implemented in 39 cases (97.5%) in the Zero ICE group. There were no significant differences in procedure time [55.5 (46.5; 66.8) min vs. 51.5 (44.0; 65.5), p = 0.50] and puncture to first ablation time [18 (13.5; 23) min vs. 19 (15; 23.5) min, p = 0.50] between the groups. The Zero ICE group had significantly lower fluoroscopy time [57 (36.3; 90) sec vs. 0 (0; 0) sec, p < 0.001] and dose [3.17 (2.27; 5.63) mGy vs. 0 (0; 0) mGy, p < 0.001] compared to the Standard ICE group. Total ablation time was longer in the Standard ICE group [597 (447; 908) sec vs. 430 (260; 750), p = 0.02], but total ablation energy [22,458 (14,836; 31,116) Ws vs. 17,043 (10,533; 29,302) Ws, p = 0.10] did not differ significantly. First-pass bidirectional conduction block of the CTI and acute reconnection rates were similar between the groups. No complications or recurrences were observed during the follow-up period. Conclusion: Our study suggests that zero-fluoroscopy CTI ablation guided solely by ICE for AFl is feasible and safe. Further investigation is warranted for broader validation.

12.
Eur Heart J Case Rep ; 7(8): ytad370, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37575541

RESUMEN

Background: Cavotricuspid isthmus pulsed-field ablation has been recently described to be safely performed despite initial reports on coronary arterial spasm while conduction disturbances as a complication of cavotricuspid isthmus ablation are rare and have been reported exclusively for radiofrequency catheter ablation. Case summary: A 64-year-old female patient with mechanical prosthetic valves underwent atrial fibrillation ablation using the pentaspline pulsed-field ablation catheter. At the end of the uneventful pulmonary vein isolation, an atrial tachycardia depended to the cavotricuspid isthmus occurred. A single pulsed-field application at the cavotricuspid isthmus resulted in right bundle branch block combined with posterior fascicular hemiblock and PR prolongation that resolved spontaneously within 12 h. Discussion: This is the first report of transient conduction disturbances as a complication of cavotricuspid isthmus pulsed-field ablation. Although the underlying mechanism, either single or miscellaneous, was not verified, this case highlights that caution should be taken when the pentaspline pulsed-field ablation catheter is used for cavotricuspid isthmus ablation.

13.
Cardiovasc Ultrasound ; 21(1): 13, 2023 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-37537565

RESUMEN

INTRODUCTION: One of the most helpful aspects of intracardiac echocardiography (ICE) implementation in electrophysiological studies (EPS) is the real-time visualisation of catheters and cardiac structures. In this prospective study, we investigated ICE-guided zero-fluoroscopy catheter navigation during radiofrequency (RF) ablation of the cavotricuspid isthmus (CTI) in patients with typical atrial flutter (AFL). METHODS AND RESULTS: Thirty consecutive patients (mean age 72.9 ± 11.4 years, 23 male) with ongoing (n = 23) or recent CTI-dependent AFL underwent an EPS, solely utilizing ICE for catheter navigation. Zero-fluoroscopy EPS could be successfully accomplished in all patients. Mean EPS duration was 41.4 ± 19.9 min, and mean ablation procedure duration was 20.8 ± 17.1 min. RF ablation was applied for 6.0 ± 3.1 min (50W, irrigated RF ablation). Echocardiographic parameters, such as CTI length, prominence of the Eustachian ridge (ER), and depth of the CTI pouch on the ablation plane, were assessed to analyse their correlation with EPS- or ablation procedure duration. The CTI pouch was shallower in patients with an ablation procedure duration above the median (4.8 ± 1.1 mm vs. 6.4 ± 0.9 mm, p = 0.04), suggesting a more lateral ablation plane in these patients, where the CTI musculature is stronger. CTI length or ER prominence above the respective median did not correlate with longer EPS duration. CONCLUSIONS: Zero-fluoroscopy CTI ablation guided solely by intracardiac echocardiography in patients with CTI-dependent AFL is feasible and safe. ICE visualisation may help to localise the optimal ablation plane, detect and correct poor tissue contact of the catheter tip, and recognise early potential complications during the ablation procedure.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Resultado del Tratamiento , Estudios Prospectivos , Catéteres , Ecocardiografía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Fluoroscopía
14.
Clin Cardiol ; 46(10): 1185-1193, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37489870

RESUMEN

BACKGROUD: Cavo- tricuspid isthmus dependent atrial flutter (CTI- AFL) is a common atrial arrhythmia in patients with prior cardiac surgery (postsurgical AFL) and without prior cardiac surgery (nonsurgical AFL). However, there is only limited data regarding the eletrophysiological differences between the CTI- AFL in the postsurgical patients and the nonsurgical patients. HYPOTHESIS: We aimed to investigate the differences in clinical and electrophysiological characteristics between the postsurgical group and nonsurgical group and to evaluate the acute and long-term outcomes after ablation guided by robotic magnetic navigation (RMN) in both the groups. Methods Fourty-two consecutive patients with nonsurgical AFL and 21 with postsurgical AFL were retrospectively analyzed in our center. Electrocardiographic (ECG) analysis and three-dimensional electrophysiological study were performed in all the patients. RESULTS: The results revealed that only 55.6% of postsurgical patients with proven counterclockwise (CCW) AFL presented with a typical ECG suggesting this mechanism. In contrast, 86.1% of nonsurgical patients demonstrated a typical ECG pattern for CCW AFL. In addition, we employed a reverse "U-curve" to facilitate radiofrequency delivery when ablating near the inferior vena cava ostium in the present study. Compared with the nonsurgical group, electroanatomical mapping showed the mean AFL cycle length was significantly longer (253.3 ± 40.4 vs. 234.1 ± 24.2 ms, p = 0.03) and the right atrium volume was larger (114.8 ± 26.0 vs. 97.5 ± 19.1 mL, p = 0.004) in the postsurgical group. Additionally, the procedural time (75.9 ± 21.3 vs. 61.6 ± 26.6 minutes, p = 0.03) and ablation time (53.0 ± 21.4 vs. 36.7 ± 25.6 minutes, p = 0.02) are much longer in the postsurgical group. However, the navigation index in the postsurgical group was significantly smaller (0.35 ± 0.08 vs. 0.43 ± 0.13, p = 0.01). Moreover, the acute and long-term success rates were comparable between the two groups. CONCLUSIONS: Catheter ablation of CTI-AFL with and without prior cardiac surgery guided by RMN are associated with high acute and long-term success rates, despite the procedural and ablation times are much longer in the postsurgical patients. However, ECG characteristics of the tachycardia may be misleading as they are more often atypical in patients after cardiac surgery.


Asunto(s)
Aleteo Atrial , Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Procedimientos Quirúrgicos Robotizados , Humanos , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Fenómenos Magnéticos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
15.
Heart Rhythm O2 ; 4(6): 350-358, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37361616

RESUMEN

Background: The optimal ablation index (AI) value for cavotricuspid isthmus (CTI) ablation is unknow. Objective: This study investigated the optimal AI value and whether preassessment of local electrogram voltage of CTI could predict first-pass success of ablation. Methods: Voltage maps of CTI were created before ablation. In the preliminary group, the procedure was performed in 50 patients targeting an AI ≥450 on the anterior side (two-thirds segment of CTI) and AI ≥400 on the posterior side (one-third segment of CTI). The modified group also included 50 patients, but the target AI for the anterior side was modified to ≥500. Results: In the modified group, the first-pass rate of success was higher (88% vs 62%; P < .01) than in the preliminary group, and there were no differences in the average bipolar and unipolar voltages at the CTI line. Multivariate logistic regression analysis revealed that ablation with an AI ≥500 on the anterior side was the only independent predictor (odds ratio 4.17; 95% confidence interval 1.44-12.05; P < .01). The bipolar and unipolar voltages were higher at sites without conduction block than at sites with conduction block (both P < .01). The cutoff values for predicting conduction gap were ≥1.94 mV and ≥2.33 mV with areas under the curve of 0.655 and 0.679, respectively. Conclusions: CTI ablation with a target AI >500 on the anterior side was shown to be more effective than an AI >450, and local voltage at a conduction gap was higher than without a conduction gap.

16.
Front Cardiovasc Med ; 10: 1109404, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37139138

RESUMEN

Introduction: While in the CASTLE-AF trial, in patients with atrial fibrillation and heart failure with reduced ejection fraction, interventional therapy using pulmonary vein isolation was associated with outcome improvement, data on cavotricuspid isthmus ablation (CTIA) in atrial flutter (AFL) in the elderly is rare. Methods: We included 96 patients between 60 and 85 years with typical AFL and heart failure with reduced or mildly reduced ejection fraction (HFrEF/HFmrEF) treated in two medical centers. 48 patients underwent an electrophysiological study with CTIA, whereas 48 patients received rate or rhythm control and guideline-compliant heart failure therapy. Patients were followed up for 2 years, with emphasis on left ventricular ejection fraction (LVEF) over time. Primary endpoints were cardiovascular mortality and hospitalization for cardiac causes. Results: Patients with CTIA showed a significant increase in LVEF after 1 (p < 0.001) and 2 years (p < 0.001) in contrast to baseline LVEF. Improvement of LVEF in the CTIA group was associated with significantly lower 2-year mortality (p = 0.003). In the multivariate regression analysis, CTIA remained the relevant factor associated with LVEF improvement (HR: 2.845 CI:95% 1.044-7.755; p = 0.041). Elderly patients (≥ 70 years) further benefited from CTIA, since they showed a significantly reduced rehospitalization (p = 0.042) and mortality rate after 2 years (p = 0.013). Conclusions: CTIA in patients with typical AFL and HFrEF/HFmrEF was associated with significant improvement of LVEF and reduced mortality rates after 2 years. Patient age should not be a primary exclusion criterion for CTIA, since patients ≥70 years also seem to benefit from intervention in terms of mortality and hospitalization.

17.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1786-1801, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37227340

RESUMEN

BACKGROUND: Because of its safety, "single-shot" pulsed field ablation (PFA) catheters have been developed for pulmonary vein isolation (PVI). However, most atrial fibrillation (AF) ablation procedures are performed with focal catheters to permit flexibility of lesion sets beyond PVI. OBJECTIVES: This study sought to determine the safety and efficacy of a focal ablation catheter able to toggle between radiofrequency ablation (RFA) or PFA to treat paroxysmal or persistent AF. METHODS: In a first-in-human study, a focal 9-mm lattice tip catheter was used for PFA posteriorly and either irrigated RFA (RF/PF) or PFA (PF/PF) anteriorly. Protocol-driven remapping was at ∼3 months postablation. The remapping data prompted PFA waveform evolution: PULSE1 (n = 76), PULSE2 (n = 47), and the optimized PULSE3 (n = 55). RESULTS: The study included 178 patients (paroxysmal/persistent AF = 70/108). Linear lesions, either PFA or RFA, included 78 mitral, 121 cavotricuspid isthmus, and 130 left atrial roof lines. All lesion sets (100%) were acutely successful. Invasive remapping of 122 patients revealed improvement of PVI durability with waveform evolution: PULSE1: 51%; PULSE2: 87%; and PULSE3: 97%. After 348 ± 652 days of follow-up, the 1-year Kaplan-Meier estimates for freedom from atrial arrhythmias were 78.3% ± 5.0% and 77.9% ± 4.1% for paroxysmal and persistent AF, respectively, and 84.8% ± 4.9% for the subset of persistent AF patients receiving the PULSE3 waveform. There was 1 primary adverse event-inflammatory pericardial effusion not requiring intervention. CONCLUSIONS: AF ablation with a focal RF/PF catheter allows efficient procedures, chronic lesion durability, and good freedom from atrial arrhythmias-for both paroxysmal and persistent AF. (Safety and Performance Assessment of the Sphere-9 Catheter and the Affera Mapping and RF/PF Ablation System to Treat Atrial Fibrillation; NCT04141007 and NCT04194307).


Asunto(s)
Técnicas de Ablación , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Catéteres , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía
20.
J Interv Card Electrophysiol ; 66(9): 1979-1988, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36877415

RESUMEN

BACKGROUND: Catheter ablation is recommended as first-line therapy for patients with symptomatic typical AFl. Although the conventional multi-catheter approach is the standard of care for cavotricuspid isthmus (CTI) ablation, a single-catheter approach was recently described as a feasible alternative. The present study sought to compare safety, efficacy, and efficiency of single vs. multi-catheter approach for atrial flutter (AFl) ablation. METHODS: In this randomized multi-center study, consecutive patients referred for AFl ablation (n = 253) were enrolled and randomized to multiple vs. single-catheter approach for CTI ablation. In the single-catheter arm, PR interval (PRI) on the surface ECG was used to prove CTI block. Procedural and follow-up data were collected and compared between the two arms. RESULTS: 128 and 125 patients were assigned to the single-catheter and to the multi-catheter arms, respectively. In the single-catheter arm, procedure time was significantly shorter (37 ± 25 vs. 48 ± 27 minutes, p = 0.002) and required less fluoroscopy time (430 ± 461 vs. 712 ± 628 seconds, p < 0.001) and less radiofrequency time (428 ± 316 vs. 643 ± 519 seconds, p < 0.001), achieving a higher first-pass CTI block rate (55 (45%) vs. 37 (31%), p = 0.044), compared with the multi-catheter arm. After a median follow-up of 12 months, 11 (4%) patients experienced AFl recurrences (5 (4%) in the single-catheter arm and 6 (5%) in the multi-catheter arm, p = 0.99). No differences were found in arrhythmia-free survival between arms (log-rank = 0.71). CONCLUSIONS: The single-catheter approach for typical AFl ablation is not inferior to the conventional multiple-catheter approach, reducing procedure, fluoroscopy, and radiofrequency time.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Catéteres
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...