Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 144
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39297566

RESUMEN

INTRODUCTION: Tuberculosis (TB) remains a global health challenge, underscoring the need for accurate diagnosis, particularly for Latent TB Infection. This meta-analysis assesses the diagnostic performance of QuantiFERON-TB Gold Plus (QFT) using Enzyme-Linked Immunosorbent Assay (ELISA) with Chemiluminescence Immunoassay (CLIA). AREAS COVERED: We systematically reviewed studies comparing QFT-CLIA with QFT-ELISA for TB detection. The literature search was carried out on PubMed, Scopus, and Web of Science, covering publications up to September 15, 2023. We included studies that assessed sensitivity, specificity, positive and negative likelihood ratios (PLR and NLR), Diagnostic Odds Ratio (DOR), and concordance. EXPERT OPINION: QFT-CLIA demonstrated high sensitivity of 0.97 (95% CI: 0.95-0.99) and specificity of 0.99 (95% CI: 0.92-1.0), with PLR of 72.19 (95% CI: 11.25-463.17), NLR of 0.03 (95% CI: 0.02-0.05), and DOR of 2494.55 (95% CI: 301.67-20627.87). The overall agreement between QFT-CLIA and QFT-ELISA was strong (0.92, 95% CI: 0.88-0.97), although the agreement for indeterminate results was slightly lower (0.83, 95% CI: 0.70-0.96). The high diagnostic accuracy and broader quantitative range of QFT-CLIA compared to ELISA may lead to more positive results and better classification of borderline cases. However, further research is needed to validate its diagnostic capabilities.

2.
Viruses ; 16(8)2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39205260

RESUMEN

Accurate and early diagnosis of monkeypox virus (MPXV) is crucial for controlling epidemics and treating affected individuals promptly. This study aimed to assess the analytical and clinical performance of the MolecisionTM Monkeypox Virus qPCR Assay, Biorain Monkeypox Virus ddPCR Assay, and MAGLUMI® Monkeypox Virus Ag (chemiluminescence immunoassay, CLIA) Assay. Additionally, it aimed to compare the clinical application of antigen and nucleic acid assays to offer insights into using commercial monkeypox assay kits. Specimens from 117 clinical patients, serial diluted virus cell culture supernatant, and artificially created positive samples were tested to evaluate the performance of these assay kits for MPXV diagnostics. The Biorain Monkeypox Virus ddPCR Assay had a limit of detection (LoD) of 3.89 CCID50/mL, while the MolecisionTM Monkeypox Virus qPCR Assay had an LoD of 15.55 CCID50/mL. The MAGLUMI® Monkeypox Virus Ag (CLIA) Assay had an LoD of 0.500 pg/mL. The accuracy of the MolecisionTM Monkeypox Virus qPCR Assay was comparable to the Biorain Monkeypox Virus ddPCR Assay, and the MAGLUMI® Monkeypox Virus Ag (CLIA) Assay demonstrated high sensitivity. The specificity of all three MPXV diagnostic assays for clinical specimens with potential cross-reacting substances was 100%. In conclusion, this study provides valuable insights into the clinical application of monkeypox assays, supporting efforts to mitigate and control the spread of monkeypox.


Asunto(s)
Monkeypox virus , Mpox , Sensibilidad y Especificidad , Humanos , Mpox/diagnóstico , Mpox/virología , Monkeypox virus/aislamiento & purificación , Monkeypox virus/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Límite de Detección , Femenino , Juego de Reactivos para Diagnóstico/normas , Masculino , Técnicas de Diagnóstico Molecular/métodos , Antígenos Virales/análisis , Adulto , Persona de Mediana Edad
3.
Food Chem ; 458: 140217, 2024 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-38964106

RESUMEN

Pretreatment steps of current rapid detection methods for mycotoxins in edible oils not only restrict detection efficiency, but also produce organic waste liquid to pollute environment. In this work, a pretreatment-free and eco-friendly rapid detection method for edible oil is established. This proposed method does not require pretreatment operation, and automated quantitative detection could be achieved by directly adding oil samples. According to polarity of target molecules, the content of surfactant in reaction solutions could be adjusted to achieve the quantitative detection of AFB1 in peanut oil and ZEN in corn oil. The recoveries are between 96.5%-110.7% with standard deviation <10.4%, and the limit of detection is 0.17 µg/kg for AFB1 and 4.91 µg/kg for ZEN. This method realizes full automation of the whole chain detection, i.e. sample in-result out, and is suitable for the on-site detection of batches of edible oils samples.


Asunto(s)
Contaminación de Alimentos , Micotoxinas , Aceites de Plantas , Contaminación de Alimentos/análisis , Micotoxinas/análisis , Aceites de Plantas/química , Límite de Detección , Aceite de Maíz/química
4.
Pract Lab Med ; 39: e00390, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38715659

RESUMEN

Introduction: This study evaluated the clinical and analytical performances of the Access HBsAg and the Access HBsAg Confirmatory assays on the DxI 9000 Access Immunoassay Analyzer (Beckman Coulter, Inc.). Materials and methods: Diagnostic specificity and sensitivity of the Access HBsAg and Access HBsAg Confirmatory assays were evaluated by comparing the Access assays to the final HBsAg sample status determined using the Architect, PRISM, or Elecsys HBsAg assays, along with Architect or PRISM HBsAg Confirmatory assays. Imprecision, sensitivity on seroconversion panels, analytical sensitivity on WHO, and recognition of HBV variants were also evaluated. Results: A total of 7534 samples were included in the analysis (6047 blood donors, 1032 hospitalized patients, 455 positive patients' samples). Access HBsAg assay sensitivity and specificity were at 100.00% (99.19-100.0) and 99.92% (99.82-99.97), respectively. Sensitivity of Access HBsAg Confirmatory assay was 100.00% (99.21-100.0) on the 464 HBsAg positive samples. The use of a high positive algorithm for the Access HBsAg assay, wherein samples with S/CO ≥ 100.00 were considered positive without requiring repeat or confirmatory testing, was successfully evaluated with all 450 specimens with S/CO greater than 100.00 (sensitivity 100.00%; 99.19-100.0). Access HBsAg assay demonstrated good analytical performance, equivalent recognition of seroconversion panels compared to Architect assay, and an analytical sensitivity between 0.022 and 0.025 IU/mL. All HBV genotypes, subtypes and mutants were well detected without analytical sensitivity loss. Conclusion: Access HBsAg and Access HBsAg Confirmatory assays demonstrated robust performances. They provide low samples volume requirements and a simplified process, no systematic retesting for high positive samples.

6.
Foods ; 13(6)2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38540943

RESUMEN

Lactoferrin (LF), an iron-binding glycoprotein with immunological properties and a high nutritional value, has emerged as a prominent research focus in the field of food nutrition. Lactoferrin is widely distributed in raw milk and milk that has undergone low-temperature heat treatment during pasteurization, making its rapid and accurate detection crucial for ensuring the quality control of dairy products. An enzyme-linked immunosorbent assay-based analytical protocol has often been referred to for the detection of LF in real samples. Signal amplification was accomplished using the streptavidin-biotin system. Here, an automated magnetic beads-based sandwich chemiluminescence enzyme immunoassay (MBs-sCLEIA) system was developed for the quantification of lactoferrin in pasteurized milk. The MBs-sCLEIA system consists of an automated chemiluminescence-based analyzer and a lactoferrin MBs-sCLEIA assay kit. Notably, our proposed method eliminates the need for pretreatment procedures and enables the direct addition of milk samples, allowing for the automatic quantitative detection of lactoferrin within a rapid 17 min timeframe for up to eight samples simultaneously. The MBs-sCLEIA was linear over the range of 7.24-800 ng/mL and displayed a limit of detection (LOD) of 2.85 ng/mL. As its good recovery and CV values indicate, the method exhibited high precision and accuracy. Furthermore, it was verified that it was selective towards five additional common milk proteins. A good correlation was observed between the results from the MBs-sCLEIA and heparin affinity column-HPLC (r2 = 0.99042), which proves to be a useful and practicable way of conducting an accurate analysis of lactoferrin in dairy products.

7.
MethodsX ; 12: 102572, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38352663

RESUMEN

Growth differentiation factor-15 (GDF-15), a member of the transforming growth factor (TGF-ß) superfamily, and is expressed and secreted in response to inflammation, oxidative stress and hypoxia. It has been shown in several studies to be a predictor of heart failure. However, the only kits available on the market are ELISA kits, which are costly and error-prone and are not conducive for clinical use. Here, we developed a chemiluminescence kit which optimized the reaction conditions and the reaction time was reduced to 10 min. We further proved that it can be used to measure GDF-15 in serum or plasma accurately and fastly, and provide additional information for the diagnosis of heart failure disease. Methodological comparison and clinical study verified this method is a reliable, economical and highly automated blood test method.•All necessary steps and the reagents needed are provided.•Reliability of the chemiluminescence immunoassay was verified by analyzing serum GDF-15 levels from different groups.•GDF-15 can provide clinicians with reliable prediction and disease assessment of heart failure.

8.
Pract Lab Med ; 39: e00361, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38318433

RESUMEN

Background: Whether chemiluminescence immunoassay (CLIA) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for plasma aldosterone concentration (PAC) measurement can be used interchangeably in primary aldosteronism (PA) screening is still controversial. The purpose of this study was to compare CLIA to LC-MS/MS for PAC measurement in PA screening. Methods: All participants underwent aldosterone-to-renin ratio (ARR) testing. PA was diagnosed by captopril challenge test or saline infusion test. PAC in screening test was measured with CLIA and LC-MS/MS. Plasma direct renin concentration in screening and confirmatory test was measured with CLIA. The concordance between CLIA and LC-MS/MS for PAC measurement in PA screening was analyzed. Results: Twenty-one healthy volunteers, 61 patients with essential hypertension (EH) and 43 PA patients were enrolled. Median PAC by CLIA was 84.7 % higher than that by LC-MS/MS in screening test (P < 0.001). A positive correlation of PAC was observed between the two assays (Pearson r coefficient 0.770, P < 0.001). When ARR was used in differentiating PA from EH, there was no difference in the area under the receiver operating characteristic curve between CLIA and LC-MS/MS for PAC measurement (0.968 vs 0.950, P = 0.249). Conclusion: CLIA and LC-MS/MS for PAC measurement exhibited high and comparable efficacy in PA screening. CLIA is a reliable and feasible alternative in PA screening test.

9.
J Pharm Biomed Anal ; 241: 115961, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38237546

RESUMEN

Adiponectin (ADPN), which serum/plasma adiponectin levels are closely associated with insulin resistance and type 2 diabetes, and lower adiponectin levels predict an increased risk of diabetes, is a strong indicator of diabetes risk in people at high risk of diabetes in different races. Using the unique principle and performance advantages of chemiluminescence immunoassay (CLIA), an ADPN-CLIA method with high sensitivity, high specificity and wide detection range was established based on the principle of two-steps method of sandwich-type, with the magnetic particles (MPs) as the solid phase carrier and acridinium ester (AE) as the chemiluminescence reaction system. The selection of the main raw materials required, the preparation conditions of MPs-coated antibodies, the methods of AE-labeled antibodies, sample requirements and reaction modes were optimized and evaluated. AE labeling experiment was successfully performed with the labeling efficiency of 8.366 and the antibody utilization rate of 96.8%. The chemiluminescent immunoassay for ADPN had a good linear relationship from 0 ng/mL to 250 ng/mL (R2 =0.9993), with the detection limit of 0.05 ng/mL. The coefficient of variation (CV) of intra-assay and inter-assay precision were both less than 5% respectively. The recovery rates for accuracy were from 91.26% to 107.46%. The comparison experiment of 80 clinical serum samples between the developed ADPN-CLIA with the immunoturbidimetry showed that the correlation coefficient was 0.956, and the Bland-Altman analysis showed that the limits of agreement were - 0.364 and 0.433.


Asunto(s)
Adiponectina , Diabetes Mellitus Tipo 2 , Humanos , Luminiscencia , Inmunoensayo/métodos , Magnetismo , Anticuerpos , Mediciones Luminiscentes/métodos
10.
Ann Clin Biochem ; 61(1): 55-62, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37503639

RESUMEN

INTRODUCTION: The prevalence of vitamin B12 deficiency is high in at-risk populations with sometimes irreversible consequences. Beside total B12 (TVB12), active B12 (AVB12) is a promising first-line marker. Only Abbott AVB12 assays were largely evaluated and generally demonstrated benefit in clinical practice. More recently developed Roche AVB12 still requires some investigations. OBJECTIVES: Our study aimed to evaluate the Roche Elecsys® AVB12 immunoassay performance versus Roche Elecsys® TVB12 competition assay. DESIGN: and Methods: We included 175 patients at Rouen University Hospital who had a TVB12 value <300 pmol/L. We evaluated performance of AVB12 by comparing the results with TVB12 and MMA values in case of disagreement. RESULTS: Positive correlation was found between the AVB12 and TVB12. We found a disagreement between TVB12 and AVB12 in 18.8% of cases. Among 33 cases of disagreement, 76% had normal AVB12 but low TVB12, whereas 24% had low AVB12 and normal TVB12. Thirty-one MMA determinations were performed: 71% showed agreement between MMA and AVB12, versus 29% between MMA and TVB12. TVB12 reported a sensitivity (Se) at 66.7%, specificity (Sp) at 20%, positive predictive value (PPV) at 16.7% and negative predictive value (NPV) at 71.4% for the prediction of MMA elevation. We determined an optimized cut-off value of 45.5 pmol/L for AVB12, which reported a Se 66.7%, Sp 60%, PPV 30.7%, and NPV 88.9%. CONCLUSIONS: Our results provide preliminary evidence that Roche AVB12 may offer better discrimination than Roche TVB12 in the diagnosis of vitamin B12 deficiency. Further more detailed evaluation is warranted.


Asunto(s)
Deficiencia de Vitamina B 12 , Vitamina B 12 , Humanos , Ácido Metilmalónico , Deficiencia de Vitamina B 12/diagnóstico , Inmunoensayo , Valor Predictivo de las Pruebas , Biomarcadores
12.
Clin Chem Lab Med ; 62(2): 353-360, 2024 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-37746851

RESUMEN

OBJECTIVES: Cardiac troponin (cTn) is the key biomarker for diagnosis of acute coronary syndrome (ACS). We performed a complete assessment of the high-sensitivity cardiac troponin I (hs-cTnI) (CLIA) assay on the analytical performance and clinical diagnostic performance, which was compared with Abbott ARCHITECT hs-cTnI assay. METHODS: Sex-specific 99th percentile upper reference limits (URLs) were determined from a healthy population of 424 males and 408 females. High-sensitivity performance was assessed by examining the imprecision at sex-specific URLs and the detectable results above LoD in a cohort of healthy population. The diagnostic performance of the hs-cTnI (CLIA) assay was validated in a population of 934 patients with suspected ACS. RESULTS: The 99th percentile URLs were 15.3 ng/L for female, 31.3 ng/L for male and 24.2 ng/L for overall population. The total imprecision near the sex-specific 99th percentile URLs were <5 %. 76.74 % of females, 97.12 % of males and 86.69 % of overall population had cTnI values exceeding the LoD, which met the criteria of high-sensitivity troponin assay. No cross-reactivity or interference was identified. The diagnostic sensitivity, specificity, PPV, NPV, and AUC of hs-cTnI (CLIA) assay were 97.97 , 90.70, 79.02, 99.21 % and 0.9885, respectively, which were comparable to ARCHITECT hs-cTnI assay. CONCLUSIONS: hs-cTnI (CLIA) assay is a high-sensitivity troponin I method with high precision, sensitivity and specificity. The clinical diagnostic performance of hs-cTnI (CLIA) is comparable to the established ARCHITECT hs-cTnI assay. Mindray's hs-cTnI (CLIA) assay is an attractive alternative for diagnosis of myocardial infarction with a high level of accuracy and safety.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Humanos , Masculino , Femenino , Troponina I , Sensibilidad y Especificidad , Infarto del Miocardio/diagnóstico , Síndrome Coronario Agudo/diagnóstico , Bioensayo , Biomarcadores , Troponina T
13.
Clin Chim Acta ; 553: 117734, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38128818

RESUMEN

BACKGROUND: Apoptosis-associated speck-like protein containing a caspase-recruitment domain (ASC) is a promising stroke biomarker. However, a large study of human serum ASC has not yet to be reported; additionally, the diagnostic value of prehospital concentration and practicality of ASC remains unknown. METHODS: We recruited 774 Chinese stroke patients, including 523 with ischemic stroke (IS) and 251 with hemorrhagic stroke (HS) within 14 days following symptom onset in the emergency department, alongside 481 healthy individuals and 64 cognitive impairment patients as controls. Serum ASC concentrations were determined using automated chemiluminescence immunoassay, exploring the relationship between serum ASC concentration and subtypes, severity, and sampling timepoints of stroke. RESULTS: ASC concentrations were significantly higher in stroke patients compared with all controls (P < 0.001). HS patients had greater ASC concentrations than IS patients (P < 0.05). With increasing ASC concentration, the proportion of severe cases increased. The area under the receiver operating characteristic curve (AUC) for differentiating between healthy individuals and stroke patients in the hyperacute phase was 0.78; this markedly improved (0.90) when considering samples from healthy individuals and patients with subarachnoid hemorrhage (SAH) ≤ 3  h from last-known-well (LKW). CONCLUSIONS: Serum ASC is a valuable biomarker for stroke differentiation and aids in the clinical diagnosis of stroke severity and subtypes.


Asunto(s)
Proteínas Adaptadoras de Señalización CARD , Accidente Cerebrovascular , Humanos , Apoptosis , Biomarcadores , Caspasas , Accidente Cerebrovascular/diagnóstico
14.
Transfus Apher Sci ; 62(6): 103836, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37940459

RESUMEN

BACKGROUND AND OBJECTIVE: Global re-emergence of syphilis among blood donors necessitates novel diagnostic and prevention approaches that encourage timely intervention. Thus, the present study was planned to evaluate the efficiency of Chemiluminescence immunoassay (CLIA) as a screening test for syphilis. MATERIAL AND METHODS: This prospective cross-sectional observational study was conducted from October 2021 to September 2022. A total of 344 donors were enrolled by purposive sampling method, including additional 16 donors who were reactive by the Rapid plasma reagin test (RPR) during the study period. Data from three screening tests - RPR test, Treponema pallidum haemagglutination assay (TPHA) and CLIA for 360 blood donors were analysed. TPHA was considered the gold standard test. RESULTS: Of the total 360 samples tested, 21 (5.8 %) were reactive by the RPR test. Of these 21 RPR reactive samples, 19 (90.5 %) were reactive by both TPHA and CLIA, while 2 (9.5 %) RPR reactive samples were non-reactive by both TPHA and CLIA. Of the remaining 339 RPR non-reactive samples, 1 (0.3 %) sample was reactive by both TPHA and CLIA, and 1 (0.3 %) was reactive by CLIA alone. CLIA was found to have sensitivity and specificity of 100 % and 99.7 % and positive predictive value (PPV) and negative predictive values (NPV) of 95.2 % and 100 % respectively, while it was 95 %, 99.4 %, 90 %, and 99.7 %, respectively, with the RPR test. CONCLUSION: CLIA was found to have a higher sensitivity, specificity, PPV and NPV than the RPR test. Thus, CLIA can be an acceptable alternative for syphilis screening in blood donors.


Asunto(s)
Sífilis , Humanos , Sífilis/diagnóstico , Donantes de Sangre , Estudios Transversales , Luminiscencia , Estudios Prospectivos , Treponema pallidum , Sensibilidad y Especificidad , Inmunoensayo/métodos
15.
Heliyon ; 9(9): e19400, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37681153

RESUMEN

Objectives: To evaluate a two-test strategy for HIV screening in the low-prevalence population and to assess the feasibility of utilizing the optimal signal-to-cutoff (S/CO) threshold on the chemiluminescence immunoassay(CMIA) and an additional rapid test on the gold immune-chromatography assay (GICA) for screening positive patients and optimization of clinical management. Methods: We conducted a retrospective study of samples analyzed by the fourth-generation Architect HIV Ag/Ab combo assay (CMIA) in a large medical center between June 2017 and August 2020. Reactive samples underwent a second screening test using the rapid test GICA, followed by Western blot (WB) as the confirmatory test. Receiver operating characteristic (ROC) curve analysis was used to determine the optimal S/CO. We calculated sensitivity, specificity, and predictive value based on our population. The performance of the single-test strategy (CMIA) was compared with that of the two-test strategy (CMIA and GICA). Logistic regression was used to analyze the factors of clinical characteristics leading to false positive results. Results: A total of 220558 samples were screened by CMIA, and 429 patients met the inclusion criteria. Of these, CMIA produced 199 false-positive results with a median S/CO of 1.93(IQR1.45-3.68) and 230 positive results with a median S/CO of 455.1 (IQR169.3-709.7). The optimal S/CO of the single-test strategy was 8.82, which achieved a sensitivity of 100% and a positive predictive value (PPV) of 90.9%. The two-test strategy (CMIA and GICA) provided a sensitivity of 100% and a PPV of 98.7%, which best correlated with the confirmatory test WB. The combination of S/CO 8.82 on the CMIA assay and additional test results of GICA can be defined as four types used to interpret HIV serostatus. The false positive rate (FPR) was high in the female, the age≤18 group, the pre-operative patients, and the patients from the clinical departments of Pediatrics, Gynecology and Obstetrics, and Oncology, etc. Conclusions: The false positive rate is high in the low-prevalence setting by using CMIA. The two-test strategy (CMIA and GICA) is recommended for HIV screening in hospitals. Hopefully, the clinicians will be able to interpret HIV serostatus and facilitate clinical decision-making while waiting for the confirmatory results.

16.
Endocr Connect ; 12(11)2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37610766

RESUMEN

Objective: Vitamin D plays an important role during pregnancy. The aim was to compare vitamin D status in a group of singleton (SP) and twin pregnancies (TP) using two diagnostic methods: chemiluminescence immunoassay (CLIA) and liquid chromatography with tandem mass spectrometry (LC-MS/MS). Design: This is a cross-sectional study. Methods: The study was conducted in the population of SP and TP at the gestational age above 20 + 0 at the Bielanski Hospital in Warsaw, Poland, between October 2020 and January 2023. All patients had their venous blood samples collected and were given an original survey containing questions on demography and vitamin D supplementation. Results: The study group included 53 Caucasian women with SP and 78 with TP aged from 21 to 47. Considering LC-MS/MS, patients with TP had lower concentrations of 25-hydroxyvitamin D (25(OH)D) than patients with SP. However, no significant difference was observed in the frequency of the occurrence of vitamin D deficiency (25(OH)D < 30 ng/mL). In both groups, the levels obtained with CLIA were significantly lower than in case of LC-MS/MS, however, strongly correlated. The intermethod agreement accounted for 52.4% and the Cohen's kappa coefficient was 0.142. Conclusions: The concentration of 25(OH)D in pregnant women depends on the type of gestation (SP/TP) and on the diagnostic methods used (CLIA/LC-MS/MS). Based on LC-MS/MS, the incidence of vitamin D deficiency was low in our group and no differences occurred in its frequency between SP and TP. The intermethod agreement between CLIA and LC-MS/MS on the detection of vitamin D deficiency was low. Significance statement: This is the first study to compare the concentration of 25(OH)D levels between SP and TP using two methods: CLIA and the gold standard - LC-MS/MS. Based on LC-MS/MS, a low incidence of vitamin D deficiency was observed in our group, in which the vast majority of patients took cholecalciferol supplements. Moreover, there were no differences in its frequency between SP and TP. However, the 25(OH)D level was significantly lower in TP. The intermethod agreement between CLIA and LC-MS/MS on the detection of vitamin D deficiency was low, which is associated with substantial clinical implications.

17.
J Virol Methods ; 319: 114770, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37419419

RESUMEN

BACKGROUND: Hepatitis C virus (HCV) infection screening and diagnosis are critical to control the hepatitis C epidemic. Testing for anti-HCV antibodies (Ab) in blood samples is the first step to screen people who have been infected with the virus. OBJECTIVES: To evaluate the performance of the MAGLUMI Anti-HCV (CLIA) Test for detection of HCV antibodies. STUDY DESIGN: To assess the diagnostic specificity, serum samples from 5053 unselected donors and 205 blood specimens from hospitalized patients were collected. To evaluate the diagnostic sensitivity, 400 positive HCV Ab samples were collected and 30 seroconversion panels were tested. All samples that met the test criteria were tested with the MAGLUMI Anti-HCV (CLIA) Test according to manufacturer's instruction. Results of the MAGLUMI Anti-HCV (CLIA) Test were compared with the Abbott ARCHITECT anti-HCV reference test. RESULTS: The specificity of the MAGLUMI Anti-HCV (CLIA) Test was 99.75% and 100.00% in blood donor and hospitalized patient samples, respectively. The sensitivity of the Test in HCV Ab positive samples was 100.00%. Seroconversion sensitivity was comparable between the MAGLUMI Anti-HCV (CLIA) Test and the reference assay. CONCLUSIONS: The performance of the MAGLUMI Anti-HCV (CLIA) Test makes it suited for HCV infection diagnosis.


Asunto(s)
Hepacivirus , Hepatitis C , Humanos , Anticuerpos contra la Hepatitis C , Sensibilidad y Especificidad , Hepatitis C/diagnóstico , Tamizaje Masivo/métodos , Inmunoensayo/métodos
18.
Talanta ; 265: 124870, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37418955

RESUMEN

Single atom nanozymes (SAzymes) are considered as the most hopeful candidates for replacing natural enzymes. In this work, a flow-injection chemiluminescent immunoassay (FI-CLIA) based on a Fenton-like activity single atom cobalt nanozyme (Co SAzyme) was developed for the rapid and sensitive detection of 5-fluorouracil (5-Fu) in serum for the first time. Co SAzyme was prepared by an in-situ etching method at room temperature using ZIF-8 metal-organic frameworks (ZIF-8 MOFs). With excellent chemical stability and ultra-high porosity of ZIF-8 MOFs as the core, Co SAzyme presents high Fenton-like activity which can catalyze the decomposition of H2O2 to produce large amounts of superoxide radical anions, thus effectively amplifying the chemiluminescence of the Luminol-H2O2 system. In addition, carboxyl-modified resin beads were used as the substrate to load more antigens due to its advantages of good biocompatibility and large specific surface area. Under optimal conditions, the detection range of 5-Fu was 0.001-1000 ng mL-1 with a limit of detection of 0.29 pg mL-1 (S/N = 3). Furthermore, the immunosensor was successfully applied for the detection of 5-Fu in human serum samples with satisfactory results, displaying the potential application of this strategy for bioanalysis and clinical diagnosis.


Asunto(s)
Técnicas Biosensibles , Humanos , Técnicas Biosensibles/métodos , Fluorouracilo , Peróxido de Hidrógeno/química , Luminiscencia , Inmunoensayo/métodos , Límite de Detección
19.
J Immunol Methods ; 520: 113513, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37307908

RESUMEN

Echinococcosis is a kind of parasitic disease shared by humans and animals. The aim of this study was to establish a new detection method for echinococcosis screening using magnetic bead-based chemiluminescence immunoassay (CLIA). A magnetic bead-based CLIA to determine anti-echinococcosis IgG antibodies was optimized and established. The sensitivity, accuracy, precision and recovery rate were evaluated using the national reference serum, and the reference interval, specificity and comparison assays were performed using the clinical negative/positive echinococcosis serum samples. This study established a new CLIA to determine anti-echinococcosis IgG antibodies. The sensitivity of this CLIA method was higher than that of the registered ELISA kit and the national standard, the conformance rate of the negative/positive references was 100% (8/8), the CVs of the sensitivity reference were all below 5%, and the CVs of the precision reference were 5.7%. There was no obvious cross-reactivity with the common parasitic disease-positive serum and serum interferents. Clinical sample testing found that the cutoff value of this CLIA was 5537.15 (RLU), and there was no significant difference between the CLIA method and the registered ELISA kit. This study established a fully automated CLIA method with high sensitivity, specificity, accuracy, precision, recovery rate, and satisfactory clinical testing performance, which may provide a new choice for echinococcosis screening.


Asunto(s)
Inmunoglobulina G , Luminiscencia , Animales , Humanos , Ensayo de Inmunoadsorción Enzimática , Inmunoensayo/métodos , Sensibilidad y Especificidad , Mediciones Luminiscentes/métodos
20.
Diseases ; 11(2)2023 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-37366871

RESUMEN

Infectious diseases such as HIV and HBV are a global concern for their impact in terms of public health and costs for national health services. A central role in contrasting the spread of the infections is represented by timely diagnosis. The speed of detection depends on several factors including the type of test used. Antibody response to hepatitis B surface antigens (anti-HBs) is an important serological marker used for HBV-infection detection. The aim of this study was to compare the performance of the Abbott system and of the new analyser Mindray 1200i in the detection of HBV- and HIV-infections. Clinical serum samples were collected from patients randomly selected from PTV University Hospital of University of Rome "Tor Vergata" and tested for HBV and HIV antibodies. Samples were evaluated by Mindray Cl 1200i CLIA screening tests for HBV and HIV and the results were compared with the Abbott Architect analytical system, the routine instrument of the hospital clinical biochemistry laboratory. Precision study, linearity, and carryover were performed on the results obtained. The agreement between the results of the Abbott and Mindray CLIA ranged from 99% to 100% and the discrepancy rate from 0% to 1%. The measurements demonstrated that the Mindray CL-1200i platform offers high-level performance with accurate and consistent test results and could represent a valuable tool if implemented in routine analysis.