1.
Cureus ; 16(5): e60741, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38903382

RESUMEN

Insertable cardiac monitor (ICM), used for long-term heart rhythm monitoring, often experiences diagnostic challenges such as T-wave oversensing, leading to false positives. This case report presents a novel approach to rectifying T-wave oversensing in ICM implantations. In this case, we are sharing a 38-year-old female with recurrent syncopal episodes who underwent ICM implantation (LUX-Dx™, ICM-Boston Scientific, Marlborough, United States). Post-implantation, T-wave oversensing was detected. Instead of the usual readjustment or reinsertion, we employed a non-invasive method of repositioning the ICM at a 45-degree angle toward the right side of the heart through the existing incision. This effectively resolved the oversensing issue without complications or the need for a new incision. ICMs are vital in linking symptoms to arrhythmias, especially in cases where standard diagnostic tools fall short. Despite their utility, ICMs are susceptible to T-wave oversensing due to subcutaneous placement. Our case demonstrates a successful alternative approach to address this, enhancing ICM's diagnostic accuracy without invasive procedures. This case highlights the potential of repositioning ICMs as a simple, non-invasive solution to overcome T-wave oversensing issues. It calls for further research and discussion within the medical community to explore its wider applicability, thereby improving ICM efficacy in clinical practice. The patient experienced no complications following the procedure during the three-month visit with appropriate sensing, validating this approach as a feasible option in similar cases.

3.
Int J Cardiol ; 413: 132301, 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-38944347

RESUMEN

AIMS: Guidelines recommend insertable cardiac monitor (ICM) in the early phases of the evaluation of unexplained syncope (US) syncope, when an arrhythmic etiology is suspected. We examined the diagnostic yield of the last generation ICM (LG-ICM) to establish the causes of US, by assessing in the clinical practice the incidence of: relevant arrhythmia diagnosis, syncope recurrences and CM-guided cardiac electronic device (CIED) implantation. We investigated also baseline patient characteristics associated to an increased risk of relevant arrhythmias and of syncope recurrence. METHODS: Data prospectively collected from consecutive patients receiving LG-ICM for investigation of US or presyncope in our institution between November 2020 and January 2023 were analyzed. RESULTS: A total of 109 patients (mean age 64.4 ± 16.1 years, 40.4% women) with US or pre-syncope episodes underwent implantation of the LG-ICM. During a mean follow-up of 11.7 ± 8.1 months, LG-ICM diagnostic yield was 42%. In particular, LG-ICM detected cardiac arrhythmias in 29 (27%) patients (in 6 out of them during a syncope recurrence) and to exclude the arrhythmic origin of the syncope in additional 19 (17%) patients. LG-ICM guided the implantation of a CIED in 16 (15%) US patients, due to the diagnosis of asystole or severe bradycardia. Age ≥ 65 years (p = 0.012) and atrial arrhythmia history (p = 0.004) are significant independent predictors of arrhythmic diagnoses performed by LG-ICM, while CAD is predictor of syncope recurrence (bordering on statistical significance, p = 0.056). CONCLUSIONS: The diagnostic yield of LG-ICM in US syncope is comparable to those of ILR and previous generation ICM. The advantages of LG-ICM should be sought in lower hospital workload necessary to manage ICM data. Age ≥ 65 years and atrial arrhythmia history are independent predictors of significant ICM-detected arrhythmias.


Asunto(s)
Arritmias Cardíacas , Electrocardiografía Ambulatoria , Síncope , Humanos , Síncope/diagnóstico , Síncope/etiología , Síncope/fisiopatología , Femenino , Masculino , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Arritmias Cardíacas/diagnóstico , Anciano de 80 o más Años , Estudios de Seguimiento , Diseño de Equipo
4.
Artículo en Inglés | MEDLINE | ID: mdl-38755520

RESUMEN

BACKGROUND: The LUX-Dx™ is a novel insertable cardiac monitor (ICM) introduced into the European market since October 2022. PURPOSE: The aim of this investigation was to provide a comprehensive description of the ICM implantation experience in Europe during its initial year of commercial use. METHODS: The system comprises an incision tool and a single-piece insertion tool pre-loaded with the small ICM. The implantation procedure involves incision, creation of a device pocket, insertion of the ICM, verification of sensing, and incision closure. Patients receive a mobile device with a preloaded App, connecting to their ICM and transmitting data to the management system. Data collected at European centers were analyzed at the time of implantation and before patient discharge. RESULTS: A total of 368 implantation procedures were conducted across 23 centers. Syncope (235, 64%) and cryptogenic stroke (34, 9%) were the most frequent indications for ICM. Most procedures (338, 92%) were performed in electrophysiology laboratories. All ICMs were successfully implanted in the left parasternal region, oriented at 45° in 323 (88%) patients. Repositioning was necessary after sensing verification in 9 (2%) patients. No procedural complications were reported, with a median time from skin incision to suture of 4 min (25th-75th percentiles 2-7). At implantation, the mean R-wave amplitude was 0.39 ± 0.30 mV and the P-wave visibility was 91 ± 20%. Sensing parameters remained stable until pre-discharge and were not influenced by patient characteristics or indications. Procedural times were fast, exhibited consistency across patient groups, and improved after an initial experience with the system. Operator Operator feedback on the system was positive. Patients reported very good ease of use of the App and low levels of discomfort after implantation. CONCLUSIONS: LUX-Dx™ implantation appears efficient and straightforward, with favorable post-implantation sensing values and associated with positive feedback from operators and patients.

5.
Pflugers Arch ; 476(7): 1145-1154, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38703193

RESUMEN

Arrhythmia detection is essential when assessing the safety of novel drugs and therapies in preclinical studies. Many short-term arrhythmia monitoring methods exist, including non-invasive ECG and Holter. However, there are no reliable, long-term, non-invasive, or minimally invasive methods for cardiac arrhythmia follow-up in large animals that allows free movement with littermates. A long follow-up time is needed when estimating the impact of long-lasting drugs or therapies, such as gene therapy. We evaluated the feasibility and performance of insertable cardiac monitors (ICMs) in pigs for minimally invasive, long-term monitoring of cardiac arrhythmias that allows free movement and species-specific behavior. Multiple implantation sites were tested to assess signal quality. ICMs recognized reliably many different arrhythmias but failed to detect single extrasystoles. They also over-diagnosed T-waves, resulting in oversensing. Muscle activity and natural startles of the animals caused noise, leading to a heterogeneous signal requiring post-recording evaluation. In spite of these shortcomings, the ICMs showed to be very useful for minimally invasive long-term monitoring of cardiac rhythm in pigs.


Asunto(s)
Arritmias Cardíacas , Animales , Porcinos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Electrocardiografía/métodos , Electrocardiografía/instrumentación , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/veterinaria
6.
J Clin Med ; 13(9)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38731083

RESUMEN

Background: Long-term rhythm monitoring (LTRM) can detect undiagnosed atrial fibrillation (AF) in patients at risk of AF and stroke. Circulating microRNAs (miRNAs), which have been shown to play a role in atrial electrical and structural remodelling, could help to select patients who would benefit most from LTRM. The aim of this study was to investigate whether patients with diabetes mellitus (DM) and hypertension and screen-detected subclinical AF (SCAF) using an insertable cardiac monitor (ICM) have significantly different plasma baseline levels of five selected miRNAs playing a role in the modulation of atrial electrical and structural remodelling (miR-21-5p, miR-29b-3p, miR-150-5p, miR-328-3p, and miR-432-5p) compared to those without SCAF. Methods: This study was performed at the outpatient clinic of a secondary academic teaching hospital between December 2013 and November 2015. Eligible patients were ≥65 years of age with DM and hypertension but without known heart diseases. All patients received an ICM. On the day of ICM implantation, blood samples for the measurement of plasma levels of the five miRNAs were drawn. In this post hoc analysis, we investigated their expression by reverse transcription-quantitative polymerase chain reaction. MiRNA plasma levels in patients with and without newly detected SCAF were compared. Results: We included 82 consecutive patients (median age of 71.3 years (IQR 67.4-75.1)), who were followed for a median of 588 days (IQR: 453-712 days). Seventeen patients (20.7%) had ICM-detected SCAF. Plasma levels of miR-328-3p, miR-29b-3p, miR-21-5p, miR-432-5p, and miR-150-5p were slightly but not significantly different in patients with incident SCAF compared with patients without. Conclusions: In patients with hypertension and DM, newly detected SCAF was not significantly associated with changes in expression levels of miR-21-5p, miR-29b-3p, miR-150-5p, miR-328-3p, and miR-432-5p.

8.
Heart Rhythm O2 ; 5(1): 34-40, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38312199

RESUMEN

Background: Long-term rhythm monitoring to detect atrial fibrillation (AF) following a cryptogenic stroke (CS) is well established. However, the burden of organized atrial arrhythmias in this population is not well defined. Objective: The purpose of this study was to assess the incidence and risk factors for organized atrial arrhythmias in patients with CS. Methods: We evaluated all patients with CS who received an insertable cardiac monitor (ICM) between October 2014 and April 2020. All ICM transmissions categorized as AF, tachycardia, or bradycardia were reviewed. We evaluated the time to detection of organized AF and the combination of either organized atrial arrhythmia or AF. Results: A total of 195 CS patients with ICMs were included (51% men; mean age 66 ± 12 years; mean CHA2DS2-VASC score 4.6). Over mean follow-up of 18.9 ± 11.2 months, organized atrial arrhythmias lasting ≥30 seconds were detected in 45 patients (23%), of whom 62% did not have AF. Seventeen patients had both organized atrial arrhythmia and AF, and another 21 patients had AF only. Compared to those with normal left atrial size, patients with left atrial enlargement had a higher adjusted risk for development of atrial arrhythmias (mild left atrial enlargement: hazard ratio 1.99; 95% confidence interval 1.06-3.75; moderate/severe left atrial enlargement: hazard ratio 3.06; 95% confidence interval 1.58-5.92). Conclusion: Organized atrial arrhythmias lasting ≥30 seconds are detected in nearly one-fourth of CS patients. Two-thirds of these patients did not have AF. Further studies are required to evaluate the impact of organized atrial arrhythmias on recurrent stroke risk.

9.
J Vet Cardiol ; 52: 19-27, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38402667

RESUMEN

Implantable loop recorders (ILRs) are increasingly used in equine cardiology to detect arrhythmias in the context of collapse, poor performance or monitoring for recurrence of atrial fibrillation (AF). However to date, the ILR has never been reported to be used with a remote monitoring functionality in horses, therefore the arrhythmia is only discovered when a clinician interrogates the ILR using dedicated equipment, which might delay diagnosis and intervention. This case report describes the use of an ILR with remote monitoring functionality in a horse with recurrent AF. The remote monitoring consisted of a transmission device located in the stable allowing daily transmission of arrhythmia recordings and functioning messages to an online server, available for the clinician to evaluate without specialised equipment. The ILR detected an episode of paroxysmal AF approximately three months after implantation. Seven months after implantation, initiation of persistent AF was seen on an episode misclassified by the ILR as bradycardia, and the horse was retired. This report shows the feasibility and benefits of remote monitoring for ILRs in horses, but also the shortcomings of current algorithms to interpret the equine electrocardiogram.


Asunto(s)
Fibrilación Atrial , Electrocardiografía Ambulatoria , Enfermedades de los Caballos , Caballos , Animales , Fibrilación Atrial/veterinaria , Fibrilación Atrial/diagnóstico , Enfermedades de los Caballos/diagnóstico , Electrocardiografía Ambulatoria/veterinaria , Electrocardiografía Ambulatoria/instrumentación , Masculino , Femenino
10.
J Cardiol Cases ; 29(2): 89-92, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38362579

RESUMEN

Insertable cardiac monitors (ICMs) are small electrocardiographs implanted subcutaneously to automatically record electrocardiograms when arrhythmia is detected in patients with syncope. If the ICM misses a significant arrhythmia, it may delay the diagnosis of arrhythmogenic syncope and put the patient at risk. Herein, we describe a case of undetected cardiac arrest in a patient with ICM. An 87-year-old man with syncope was admitted to the hospital. After 8 days of monitoring, the cause could not be determined, and an ICM was implanted. Nine hours after implantation, the patient experienced cardiopulmonary arrest. Despite a body surface electrocardiogram showing ventricular flatline and fibrillation, the ICM failed to record. The cause of failure to record was considered to be the fluctuation in the R-wave amplitude of the ICM and noise oversensing. In conclusion, albeit infrequently, ICMs might overlook life-threatening arrhythmias. Even in cases where the ICM fails to detect an arrhythmia matching the symptoms, it may not be feasible to entirely rule out the presence of arrhythmias. Learning objective: Insertable cardiac monitors (ICMs) are used to diagnose arrhythmogenic syncope. However, extremely infrequently, ICM may fail to record life-threatening arrhythmias. Failure to capture arrhythmias can happen due to an unfortunate combination of factors such as a low amplitude of the recorded R wave and noise. Even in cases where the ICM does not detect an arrhythmia that matches the symptoms, it may not be feasible to completely exclude the presence of arrhythmias.

11.
Int J Cardiol ; 399: 131769, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38211671

RESUMEN

BACKGROUND AND OBJECTIVE: This study's objective is to investigate whether mild aortic arch plaque is associated with the development of atrial fibrillation (AF) in stroke patients with embolic stroke of undetermined source (ESUS) during the first year following the implantation of an insertable cardiac monitor (ICM). METHODS: The participants in this cross-sectional observational study were consecutive patients with ESUS, even after transesophageal echocardiography. We assessed the relationship between the thickness of the participants' aortic arch plaque and AF detected after ICM implantation. RESULTS: Of the 50 consecutive patients with ESUS enrolled in this study, 12 (24%) developed AF. We observed that thicker aortic arch plaque was associated with undetected AF (2.3 mm vs. 1.2 mm, p < 0.001). Aortic arch plaque thickness was independent associated with undetected AF (OR 54.00, 95% CI 2.706-1077.544, p = 0.009). When the cut-off value for aortic arch plaque thickness was 1.8 mm, the sensitivity and specificity were 71.1% and 91.7%, respectively (95% CI = 0.75-0.98, p < 0.001). Also, patients having both aortic arch plaque with a thickness < 1.8 mm and a CHADS2 score ≥ 4 were more likely to have detectable AF than no AF (88% vs. 12%, p < 0.001). CONCLUSION: A thinner aortic arch plaque was associated with the development of AF. Patients with mild aortic plaques below 4 mm but ≥1.8 mm in thickness and without other high-risk features are less likely to have paroxysmal AF on ICM, and these plaques may be a possible source of embolism for their strokes.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular Embólico , Embolia Intracraneal , Placa Aterosclerótica , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/diagnóstico por imagen , Accidente Cerebrovascular Embólico/complicaciones , Aorta Torácica/diagnóstico por imagen , Estudios Transversales , Placa Aterosclerótica/diagnóstico , Placa Aterosclerótica/diagnóstico por imagen , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/epidemiología , Factores de Riesgo , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/etiología
12.
J Cardiovasc Electrophysiol ; 35(2): 341-345, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38164063

RESUMEN

INTRODUCTION: The increasing use of insertable cardiac monitors (ICMs) for long-term continuous arrhythmia monitoring creates a high volume of transmissions and a significant workload for clinics. The ability to remotely reprogram device alert settings without in-office patient visits was recently introduced, but its impact on clinic workflow compared to the previous ICM iteration is unknown. METHODS: The aim of this real-world study was to evaluate the impact of device reprogramming capabilities on ICM alert burden and on clinic workflow. Deidentified data was obtained from US patients and a total of 19 525 receiving a LINQ II were propensity score-matched with 19 525 implanted with LINQ TruRhythm (TR) ICM based on age and reason for monitoring. RESULTS: After reprogramming, ICM alerts reduced by 20.5% (p < .001). Compared with patients monitored with LINQ TR, patients with LINQ II had their device reprogrammed sooner after implant and more frequently during follow-up. Adoption of remote programming was projected to lead to an annual total clinic time savings of 211 h per 100 ICM patients managed. CONCLUSION: These data suggest that utilization of ICM alert reprogramming has increased with remote capabilities, which may reduce clinic and patient burden for ICM follow-up and free clinician time for other valuable patient care activities.


Asunto(s)
Arritmias Cardíacas , Electrocardiografía Ambulatoria , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Trastorno del Sistema de Conducción Cardíaco
13.
Eur Heart J ; 45(7): 510-518, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-37624879

RESUMEN

BACKGROUND AND AIMS: Atrial fibrillation (AF) is a chronic progressive disorder. Persistent forms of AF are associated with increased rates of thromboembolism, heart failure, and death. Catheter ablation modifies the pathogenic mechanism of AF progression. No randomized studies have evaluated the impact of the ablation energy on progression to persistent atrial tachyarrhythmia. METHODS: Three hundred forty-six patients with drug-refractory paroxysmal AF were enrolled and randomly assigned to contact-force-guided RF ablation (CF-RF ablation, 115), 4 min cryoballoon ablation (CRYO-4, 115), or 2 min cryoballoon ablation (CRYO-2, 116). Implantable cardiac monitors placed at study entry were used for follow-up. The main outcome was the first episode of persistent atrial tachyarrhythmia. Secondary outcomes included atrial tachyarrhythmia recurrence and arrhythmia burden on the implantable monitor. RESULTS: At a median of 944.0 (interquartile range [IQR], 612.5-1104) days, 0 of 115 patients (0.0%) randomly assigned to CF-RF, 8 of 115 patients (7.0%) assigned to CRYO-4, and 5 of 116 patients (4.3%) assigned to CRYO-2 experienced an episode of persistent atrial tachyarrhythmia (P = .03). A documented recurrence of any atrial tachyarrhythmia ≥30 s occurred in 56.5%, 53.9%, and 62.9% of those randomized to CF-RF, CRYO-4, and CRYO-2, respectively; P = .65. Compared with that of the pre-ablation monitoring period, AF burden was reduced by a median of 99.5% (IQR 94.0%, 100.0%) with CF-RF, 99.9% (IQR 93.3%-100.0%) with CRYO-4, and 99.1%% (IQR 87.0%-100.0%) with CRYO-2 (P = .38). CONCLUSIONS: Catheter ablation of paroxysmal AF using radiofrequency energy was associated with fewer patients developing persistent AF on follow-up.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Taquicardia , Recurrencia , Venas Pulmonares/cirugía
14.
J Interv Card Electrophysiol ; 67(3): 617-623, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37700118

RESUMEN

BACKGROUND: There is growing interest in the possibility of discontinuing oral anticoagulation following successful catheter ablation of atrial fibrillation (AF). However, it remains unknown whether patients can accurately detect arrhythmia recurrences following ablation. We therefore sought to characterize the accuracy of pulse checking and arrhythmia symptoms for the identification of AF following ablation. METHODS: This prospective cohort study included patients at the Hospital of the University of Pennsylvania with an insertable cardiac monitor (ICM) treated with catheter ablation for AF who recorded the results from minimum twice daily pulse checks and additionally with arrhythmia symptoms into a diary for 2 months following their procedure. Accuracy of this self-assessment protocol was determined by comparison to ICM-detected AF. RESULTS: A total of 55 patients (age 69 ± 8 years, 30 (55%) male, CHA2DS2VASc score 3.2 ± 1. 5) were included. Patients recorded a total of 5911 pulse checks, and there were 280 episodes of ICM-documented AF among 26 patients with an average duration of 2.5 ± 3.3 h. Among 362 episodes of patient-suspected AF, 134 correlated with ICM-identified AF (37% true positive rate). Of the 5549 pulse checks that did not identify AF, 196 correlated with ICM-identified AF (4% false negative rate). Twice daily pulse checking had a sensitivity of 47% and a specificity of 96% for identifying each episode of AF. CONCLUSIONS: Our data indicate that a strategy of pulse checks and symptom assessment is insufficient to identify all episodes of AF in many patients following catheter ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios Prospectivos , Electrocardiografía Ambulatoria/métodos , Frecuencia Cardíaca , Ablación por Catéter/métodos
16.
Card Electrophysiol Clin ; 15(4): 413-420, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37865515

RESUMEN

Insertable cardiac monitors (ICMs) have been used more frequently and in a wider variety of circumstances in recent years. ICMs are used for symptom-rhythm correlation when patients have potentially arrhythmogenic syncope and for less traditional reasons such as rhythm surveillance in patients with genetic arrhythmia syndromes or other diseases with high arrhythmia risk. ICMs have good diagnostic yield in pediatric patients and in adults with congenital heart disease and have a low rate of complications. Implantation techniques should take patient-specific factors into account to optimize diagnostic yield and minimize risk.


Asunto(s)
Electrocardiografía Ambulatoria , Cardiopatías Congénitas , Adulto , Humanos , Niño , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Síncope/diagnóstico , Síncope/etiología , Cardiopatías Congénitas/diagnóstico
17.
J Neurol ; 270(12): 5878-5888, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37612538

RESUMEN

BACKGROUND: An insertable cardiac monitor (ICM) and transesophageal echocardiography (TEE) are useful for investigating potential embolic sources in cryptogenic stroke, of which atrial fibrillation (AF) is a critical risk factor for stroke recurrence. The association of left atrial appendage flow velocity (LAA-FV) on TEE with ICM-detected AF is yet to be elucidated. METHODS: CRYPTON-ICM (CRYPTOgenic stroke evaluation in Nippon using ICM) is a multicenter registry of cryptogenic stroke with ICM implantation, and patients whose LAA-FV was evaluated on TEE were enrolled. The primary outcome was the detection of AF (> 2 min) on ICM. Receiver operating characteristic (ROC) curve analysis was performed to determine the optimal cut-off of LAA-FV, and factors associated with ICM-detected AF were assessed. RESULTS: A total of 307 patients (age 66.6 ± 12.3 years; 199 males) with median follow-up of 440 (interquartile range 169-726) days were enrolled; AF was detected in 101 patients. The lower-tertile LAA-FV group had older age, more history of congestive heart failure, and higher levels of B-type natriuretic peptide (BNP) or N-terminal proBNP (all P < 0.05). On ROC analysis, LAA-FV < 37.5 cm/s predicted ICM-detected AF with sensitivity of 26.7% and specificity of 92.2%. After adjustment for covariates, the lower tertile of LAA-FV (hazard ratio [HR], 1.753 [1.017-3.021], P = 0.043) and LAA-FV < 37.5 cm/s (HR 1.987 [1.240-3.184], P = 0.004) predicted ICM-detected AF. CONCLUSIONS: LAA-FV < 37.5 cm/s predicts AF. TEE is useful not only to evaluate potential embolic sources, but also for long-term detection of AF on ICM by measuring LAA-FV in cryptogenic stroke. http://www.umin.ac.jp/ctr/ (UMIN000044366).


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Masculino , Humanos , Persona de Mediana Edad , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico por imagen , Apéndice Atrial/diagnóstico por imagen , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular Isquémico/complicaciones , Ecocardiografía Transesofágica/efectos adversos , Sistema de Registros
18.
Heart Rhythm ; 20(9): 1297-1306, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37321384

RESUMEN

BACKGROUND: Fidelity of electrogram sensing may reduce false alerts from an insertable cardiac monitor (ICM). OBJECTIVE: The purpose of this study was to assess the effect of vector length, implant angle, and patient factors on electrogram sensing using surface electrocardiogram (ECG) mapping. METHODS: Twelve separate precordial single-lead surface ECGs were acquired from 150 participants at 2 interelectrode distances (75 and 45 mm), at 3 vector angles (vertical, oblique, and horizontal), and in 2 postures (upright and supine). A subset of 50 patients also received a clinically indicated ICM implant in 1:1 ratio (Reveal LINQ [Medtronic, Minneapolis, MN]/BIOMONITOR III [Biotronik, Berlin, Germany]). All ECGs and ICM electrograms were analyzed by blinded investigators using DigitizeIt software (V2.3.3, Braunschweig, Germany). The P-wave visibility threshold was set at > 0.015 mV. Logistic regression was used to identify factors affecting P-wave amplitude. RESULTS: A total of 1800 tracings from 150 participants (44.5% [n = 68] female; median age 59 [35-73] years) were assessed. The median P- and R-wave amplitudes were 45% and 53% larger with vector lengths of 75 and 45 mm, respectively (P < .001 for both). The oblique orientation yielded the best P- and R-wave amplitudes, while posture change did not affect P-wave amplitude. Mixed effects modeling found that visible P-waves occur more frequently with a vector length of 75 mm than with 45 mm (86% vs 75%, respectively; P < .0001). A longer vector length improved both P-wave amplitude and visibility in all body mass index categories. There was a moderate correlation of P- and R-wave amplitudes from the ICM electrograms to those from surface ECG recordings (intraclass correlation coefficient 0.74 and 0.80, respectively). CONCLUSION: Longer vector length and oblique implant angle yielded the best electrogram sensing and are relevant considerations for ICM implantation procedures.


Asunto(s)
Electrocardiografía Ambulatoria , Electrocardiografía , Humanos , Femenino , Persona de Mediana Edad , Electrocardiografía Ambulatoria/métodos , Electrocardiografía/métodos , Prótesis e Implantes , Programas Informáticos , Alemania
19.
JMIR Res Protoc ; 12: e39307, 2023 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-37052993

RESUMEN

BACKGROUND: Paroxysmal atrial fibrillation (AF) is a probable cause of cryptogenic stroke (CS), and its detection and treatment are important for the secondary prevention of stroke. Insertable cardiac monitors (ICMs) are clinically effective in screening for AF and are superior to conventional short-term cardiac monitoring. Japanese guidelines for determining clinical indications for ICMs in CS are stricter than those in Western countries. Differences between Japanese and Western guidelines may impact the detection rate and prediction of AF via ICMs in patients with CS. Available data on Japanese patients are limited to small retrospective studies. Furthermore, additional information about AF detection, including the number of episodes, cumulative episode duration, anticoagulation initiation (type and dose of regimen and time of initiation), rate of catheter ablation, role of atrial cardiomyopathy, and stroke recurrence (time of recurrence and cause of the recurrent event), was not provided in the vast majority of previously published studies. OBJECTIVE: In this study, we aim to identify the proportion and timing of AF detection and risk stratification criteria in patients with CS in real-world settings in Japan. METHODS: This is a multicenter, prospective, observational study that aims to use ICMs to evaluate the proportion, timing, and characteristics of AF detection in patients diagnosed with CS. We will investigate the first detection of AF within the initial 6, 12, and 24 months of follow-up after ICM implantation. Patient characteristics, laboratory data, atrial cardiomyopathy markers, serial magnetic resonance imaging findings at baseline, 6, 12, and 24 months after ICM implantation, electrocardiogram readings, transesophageal echocardiography findings, cognitive status, stroke recurrence, and functional outcomes will be compared between patients with AF and patients without AF. Furthermore, we will obtain additional information regarding the number of AF episodes, duration of cumulative AF episodes, and time of anticoagulation initiation. RESULTS: Study recruitment began in February 2020, and thus far, 213 patients have provided written informed consent and are currently in the follow-up phase. The last recruited participant (May 2021) will have completed the 24-month follow-up in May 2023. The main results are expected to be submitted for publication in 2023. CONCLUSIONS: The findings of this study will help identify AF markers and generate a risk scoring system with a novel and superior screening algorithm for occult AF detection while identifying candidates for ICM implantation and aiding the development of diagnostic criteria for CS in Japan. TRIAL REGISTRATION: UMIN Clinical Trial Registry UMIN000039809; https://tinyurl.com/3jaewe6a. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/39307.

20.
Eur Stroke J ; 8(1): 148-156, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-37021182

RESUMEN

Introduction: Secondary stroke prevention depends on proper identification of the underlying etiology and initiation of optimal treatment after the index event. The aim of the NOR-FIB study was to detect and quantify underlying atrial fibrillation (AF) in patients with cryptogenic stroke (CS) or transient ischaemic attack (TIA) using insertable cardiac monitor (ICM), to optimise secondary prevention, and to test the feasibility of ICM usage for stroke physicians. Patients and methods: Prospective observational international multicenter real-life study of CS and TIA patients monitored for 12 months with ICM (Reveal LINQ) for AF detection. Results: ICM insertion was performed in 91.5% by stroke physicians, within median 9 days after index event. Paroxysmal AF was diagnosed in 74 out of 259 patients (28.6%), detected early after ICM insertion (mean 48 ± 52 days) in 86.5% of patients. AF patients were older (72.6 vs 62.2; p < 0.001), had higher pre-stroke CHA2DS2-VASc score (median 3 vs 2; p < 0.001) and admission NIHSS (median 2 vs 1; p = 0.001); and more often hypertension (p = 0.045) and dyslipidaemia (p = 0.005) than non-AF patients. The arrhythmia was recurrent in 91.9% and asymptomatic in 93.2%. At 12-month follow-up anticoagulants usage was 97.3%. Discussion and conclusions: ICM was an effective tool for diagnosing underlying AF, capturing AF in 29% of the CS and TIA patients. AF was asymptomatic in most cases and would mainly have gone undiagnosed without ICM. The insertion and use of ICM was feasible for stroke physicians in stroke units.


Asunto(s)
Fibrilación Atrial , Ataque Isquémico Transitorio , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Ataque Isquémico Transitorio/complicaciones , Electrocardiografía Ambulatoria/efectos adversos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular Isquémico/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...