Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
1.
Vet Ophthalmol ; 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-39325057

RESUMEN

OBJECTIVE: To describe the removal of an adherent, presumed plant-based, anterior chamber foreign body (ACFB) from the inferior iridocorneal angle in a dog using hydropulsion and ophthalmic viscoelastic device (OVD) capture. ANIMAL STUDIED: A 6-year-old female spayed pit bull terrier who was referred for further evaluation of a corneal opacity after being observed running into a thorned succulent plant 1 month earlier. On ophthalmic examination, no corneal foreign body was noted, though mild uveitis was present. Gonioscopy revealed a suspected plant foreign body (thorn tip) in the inferior iridocorneal angle. PROCEDURE: Under general anesthesia, the ACFB was dislodged from the inferior iridocorneal angle using hydropulsion with balanced salt solution. The superior half of the anterior chamber had been filled with 2% hydroxypropyl methylcellulose OVD to trap the foreign object. One month later, the uveitis had resolved and repeat gonioscopy confirmed the absence of any ACFB in the iridocorneal angle. CONCLUSION: In the absence of an intraoperative goniolens or endoscopy, hydropulsion and OVD capture of adherent ACFBs may be a feasible option for removal.

2.
Front Ophthalmol (Lausanne) ; 4: 1422466, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39285858

RESUMEN

Intraocular foreign bodies (IOFBs) remain a severe complication of ocular trauma commonly encountered worldwide. This literature review aimed to discuss current practice patterns, areas of controversy, and advances in the management of IOFBs. Injuries involving IOFBs carry significant ocular morbidity and management can be extremely challenging. A systematic approach to preoperative evaluation and IOFB surgical management is detailed in this article and should be applied in each case. The location and composition of an IOFB have important implications on surgical approach and timing, especially in cases of toxic metals and vegetable matter. The advantages, disadvantages, and previous literature regarding immediate versus delayed foreign body removal are presented. Surgical approaches are described, with an emphasis on posterior chamber IOFB management and removal via pars plana vitrectomy. Final visual acuity is variable, but approaches have been used to prognosticate outcomes including the Ocular Trauma Score. By synthesizing current IOFB literature, the goal is to provide practitioners with guidance that will maximize the chances of surgical success and patient outcomes.

3.
BMC Ophthalmol ; 24(1): 374, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39187820

RESUMEN

BACKGROUND: Ocular siderosis (OS) is a significant cause of visual loss due to retained ferrous intraocular foreign bodies (IOFB). Despite its rarity, OS can lead to severe visual impairment if not promptly diagnosed and treated. This case is notable due to the occult nature of the IOFB, which was undetected by standard imaging modalities, emphasizing the critical role of magnetic resonance imaging (MRI) in such scenarios. CASE PRESENTATION: A 51-year-old Caucasian male presented with progressive vision loss in his right eye over 20 days. Best corrected visual acuity (BCVA) was 20/1000 in the right eye and 20/20 in the left eye. Intraocular pressure (IOP) was 9 mmHg in both eyes. Slit-lamp examination revealed a small linear corneal wound and an iris defect in the right eye, along with a cataract featuring brownish deposits on the anterior capsule. The left eye was normal. Fundus examination of the right eye was hindered by media opacities. Ultrasonography showed a flat retina and choroid with no detectable IOFB. Despite a strong clinical suspicion of OS, computed tomography (CT) did not detect any IOFB. MRI subsequently identified an artifact in the inferior sectors of the right eye, indicative of a metallic IOFB. Surgical intervention involved a 23-gauge vitrectomy, phacoemulsification, IOFB removal and silicon oil (SO) tamponade resulting in a fully restored VA of 20/20 and normal IOP one month post-operation. SO was removed 2 months later. The retina remained adherent with no PVR development, and optical coherence tomography (OCT) scans showed a normal macula. CONCLUSIONS: This case underscores the importance of considering OS in patients with unexplained vision loss and history of ocular trauma, even when initial imaging fails to detect an IOFB. MRI proved crucial in identifying the IOFB, highlighting its value in the diagnostic process. Early detection and surgical removal of IOFBs are essential to prevent irreversible visual damage. This case demonstrates that MRI should be employed when CT and ultrasonography are inconclusive, ensuring accurate diagnosis and timely intervention to preserve vision.


Asunto(s)
Cuerpos Extraños en el Ojo , Lesiones Oculares Penetrantes , Imagen por Resonancia Magnética , Siderosis , Humanos , Cuerpos Extraños en el Ojo/diagnóstico , Cuerpos Extraños en el Ojo/cirugía , Masculino , Persona de Mediana Edad , Lesiones Oculares Penetrantes/diagnóstico , Lesiones Oculares Penetrantes/cirugía , Siderosis/diagnóstico , Agudeza Visual , Vitrectomía
4.
Artículo en Inglés | MEDLINE | ID: mdl-38951225

RESUMEN

INTRODUCTION: Magnetic intraocular foreign bodies can be removed with magnetized disposable forceps. Aim of this study is to compare the forceps magnetizability of different size, form and manufacturer. METHODS: The forceps were magnetized using an established procedure. The inducible magnetic flux density was measured at the tip of the forceps. The mass that can be lifted with the magnetized forceps was then tested using steel balls in BSS solution. The weight of the metal parts of the forceps was measured. RESULTS: The magnetic flux density that could be induced, the weight of the steel balls that could be lifted and the mass of stainless steel used in the forceps were as follows: Alcon end-grasping 23G: 7.12 mT, 87.43 mg, 1191 mg; Alcon end-grasping 25G: 6.43 mT, 87.43 mg, 1189 mg; Alcon serrated: 4.39 mT, 63.78 mg, 1284 mg; Alcon serrated 23G: 3.62 mT, 13.74 mg, 1200 mg; Alcon serrated 25G: 2.4 mT, 13.74 mg, 1195 mg; DORC end-grasping 23G: 5.52 mT, 32.54 mg, 153 mg; Synergetics end-grasping 23G: 4.35 mT, 16.37 mg, 193 mg; Vitreq BV end-grasping 23G: 2.65 mT, none, 88 mg. DISCUSSION: The magnetizability of a disposable microforceps seems to depend on the mass of steel at the tip of the forceps. The structure of the iron lattice could have an even greater influence. Not every disposable forceps can be sufficiently magnetized for this technique.

5.
Front Med (Lausanne) ; 11: 1399321, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38808133

RESUMEN

Aim: To investigate the efficacy and safety profile of T-shaped pars plana scleral incision technique in removing large intraocular foreign bodies, during 23-gauge pars plana vitrectomy. Methods: Retrospective interventional case series that included patients diagnosed with a large intraocular foreign body (IOFB). Possible postoperative complications were recorded 24 h, 1 month, 3 and 6 months postoperatively. Results: Thirty eyes of 30 patients (48 ± 5 years old) were enrolled. All IOFBs were successfully removed: mean diameters of 7.8 ± 2.0 mm and 2.6 ± 0.3 mm. Silicone oil and sulfur hexafluoride were used in 27 and 3 eyes, respectively. Lensectomy was performed in 27 eyes. Intraocular lens was implanted at first attempt in 12 eyes; during a second operation in 12 eyes and 6 eyes remained aphakic. At any follow-up, no signs of postoperative complications were observed. Secondary retinal detachment occurred in 12 eyes. Mean preoperative corrected distance visual acuity was 0.04, on the Snellen scale; it increased to 0.07, at last follow-up. Mean intraocular pressure was 17.97 mmHg. All eyes were preserved. Conclusion: T-shaped scleral incision could be an effective, safe and easy-to-perform standard procedure to remove large IOFBs during pars plana vitrectomy, without increasing the risk of surgical complications and additional damage to the ocular tissues.

6.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(6): 256-259, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38521347

RESUMEN

A 54-year-old man presented to the ophthalmic emergency department of our center with eye pain and blurred vision in his right eye following a workplace accident. Examination revealed a penetrating corneal injury with the presence of an intraocular foreign body (IOFB) involving the corneoscleral limbus, perforating the cornea, iris, anterior lens capsule, and lens. Immediate surgical intervention was carried out with the extraction of the IOFB, identified as an 8mm mussel shell fragment, and the removal of the resulting traumatic cataract. Both preoperative and postoperative examinations showed an attached retina with no signs of retinal tears or vitreous hemorrhage. Appropriate management in this case, along with the timely identification of the agent, led to favorable outcomes despite the size of the intraocular foreign body.


Asunto(s)
Accidentes de Trabajo , Cuerpos Extraños en el Ojo , Lesiones Oculares Penetrantes , Cuerpos Extraños en el Ojo/cirugía , Humanos , Masculino , Persona de Mediana Edad , Lesiones Oculares Penetrantes/cirugía , Lesiones Oculares Penetrantes/etiología
7.
Am J Emerg Med ; 80: 18-23, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38479112

RESUMEN

AIMS: To characterize the clinical features of ocular trauma resulting from lawn mower, identify determinants of unfavorable final visual acuity (FVA), and assess the spectrum of microbial in posttraumatic endophthalmitis. METHODS: This retrospective study enrolled patients who experienced ocular trauma due to lawn mower at Zhongshan Ophthalmic Center from January 2013 to August 2021. Demographics, clinical features, isolated microorganisms, risk factors influencing reduced visual acuity, treatment regimens, and utilization of eyewear were collected. RESULTS: The study included 140 participants (140 eyes) (49.47 ± 12.03 years, 95% male). The predominant injury manifestations were penetrating globe injuries (75.7%) and intraocular foreign bodies (51.4%). Endophthalmitis occurred in 35 cases (25%) and Bacillus cereus (23.5%) was the primary pathogen, followed by Staphylococcus epidermidis (11.8%) and Streptococcus species (11.8%). Following the initial assessment, where 77.9% of patients had initial visual acuity (IVA) at grade IV (ranging from light perception to 4/200) and only 0.7% attained grade I (better than 20/40), post-treatment results revealed that 5.7% achieved FVA at grade I, with a concurrent decrease in patients with grade IV vision to 64.3%. Multivariate logistic regression revealed that injury protection (p < 0.001, OR = 0.237, 95% CI = 0.126-0.446), IVA (p = 0.001, OR = 4.102, 95% CI = 1.730-9.729), and retinal detachment (p = 0.042, OR = 8.105, 95% CI = 1.075-61.111) were significant independent risk factors impacting FVA. CONCLUSION: Lawn mower often cause severe ocular injuries, with high-velocity metal foreign bodies that can lead to infections, most commonly caused by Bacillus cereus. Correct use of protective gear, initial vision assessment, and detecting retinal detachment are crucial for visual prognosis.


Asunto(s)
Endoftalmitis , Agudeza Visual , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Endoftalmitis/microbiología , Endoftalmitis/epidemiología , Adulto , Cuerpos Extraños en el Ojo/complicaciones , Cuerpos Extraños en el Ojo/epidemiología , Lesiones Oculares Penetrantes/complicaciones , Lesiones Oculares Penetrantes/epidemiología , Lesiones Oculares/epidemiología , Lesiones Oculares/complicaciones , Factores de Riesgo , Anciano , China/epidemiología
8.
Cureus ; 16(2): e53839, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38465104

RESUMEN

Ocular siderosis bulbi is a rare but significant cause of vision impairment in patients with a retained ferrous intraocular foreign body (IOFB). In this report, we present two cases of ocular manifestations suggestive of siderosis bulbi. Both cases presented with a significant reduction in vision and were found to have a dense cataract, a small healed corneal scar, and siderotic pigments in the anterior chamber. The first case denied any past ocular injury, yet CT scans confirmed the presence of an IOFB. The second case, who had a high suspicion of ocular trauma, did not have a radiologically detectable IOFB. Both cases underwent combined cataract extraction surgery with pars plana vitrectomy and IOFB removal, resulting in a favorable visual outcome despite developing siderosis.

9.
BMC Ophthalmol ; 24(1): 80, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38383362

RESUMEN

PURPOSE: To compare the efficacy and efficiency of self-assembled intraocular rare earth magnet and forceps in removing intraocular foreign bodies(IOFBs) undergoing 25-gauge(G) pars plana vitrectomy. METHODS: A total of 30 patients with metallic IOFB underwent 25-G PPV were enrolled into this study. Self-assembled intraocular rare earth magnet were used in 15 patients(bar group), and forceps were used in 15 patients(forceps group). Success rate of removing IOFB, time taken to remove IOFB, incidence of IOFB slippage and fall, iatrogenic retinal damages were compared between the two groups. RESULTS: There was no significant difference in success rate of removing IOFBs between the groups(93.3% and 100%, P > 0.99). The median time taken of removing FB was significantly shorter in bar group than in forceps group(112 and 295 s, P = 0.001). None of the patients in bar group had IOFB slippage and fall, or related iatrogenic retinal damage in the process of removal. In forceps group, IOFB slippage and fall during removal were observed in 7 of 15(47.6%) patients, related iatrogenic retinal injuries were recorded in 6 of 15(40.0%) patients, both were significantly higher than bar group(P = 0.003 and P = 0.017, respectively). CONCLUSIONS: Compared with forceps, the assembled intraocular magnet can greatly reduce the possibility of IOFB slippage and fall, prevent related iatrogenic retinal damage, and shorten the time taken to remove IOFB. The assembled intraocular magnet can be an useful tool in removing metallic IOFBs in PPV.


Asunto(s)
Cuerpos Extraños en el Ojo , Lesiones Oculares Penetrantes , Enfermedades de la Retina , Humanos , Vitrectomía , Imanes , Estudios Retrospectivos , Cuerpos Extraños en el Ojo/etiología , Cuerpos Extraños en el Ojo/cirugía , Instrumentos Quirúrgicos , Enfermedades de la Retina/cirugía , Enfermedad Iatrogénica , Lesiones Oculares Penetrantes/etiología , Lesiones Oculares Penetrantes/cirugía
10.
Front Med (Lausanne) ; 11: 1303683, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38384411

RESUMEN

Background: Open globe injuries (OGIs) are one of the leading causes of monocular vision loss, and the clinical characteristics of OGIs are region specific. The features and patterns of OGIs in Southwest China are poorly known and not well studied. Our study aimed to review the epidemiological and clinical characteristics of patients hospitalized for OGIs in Southwest China. Methods: A retrospective study of OGI patients admitted to the West China Hospital from January 1st, 2015, to December 31st, 2019, was performed. Demographic characteristics and injury details were recorded. The Birmingham Eye Trauma Terminology system and the ocular trauma score (OTS) were used. Results: A total of 3,014 patients were included. The male-to-female ratio was 5.2:1, and the mean age was 35.6 ± 19.1 years. 15.2% of patients were from the ethnic groups. The highest-risk occupation was the farmer (30.3%), followed by the worker (28.5%). OGIs occurred more frequently in people with middle (37.0%) and primary school (33.1%) education levels. Types of injuries included 46.8% penetration, 21.2% rupture, 2.9% perforation, and 29.1% intraocular foreign body (IOFB). The injuries types differed between age and occupation groups (p < 0.001). IOFBs had a higher risk of causing endophthalmitis, retinal detachment, and traumatic cataracts (p < 0.001). The most common injuries resulted from sharp objects (72.7%). The causes of the injuries were significantly associated with age, ethnicity, and occupation (p < 0.001). Explosion injuries and attacks by animals were more common among people of Tibetan and Yi ethnicities. Blunt trauma, vehicle crashes, falls and age older than 60 years were risk factors for a lack of light perception and lower OTS scores prognosis. Conclusion: OGIs in Southwest China mainly affected working-aged males, especially workers or farmers. Severe vision loss and IOFBs are more common findings. OGIs in older patients and ethnic minorities requires additional attention.

12.
Open Vet J ; 13(10): 1379-1384, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38027412

RESUMEN

Background: Intra-lenticular foreign bodies are rare in veterinary medicine and uncommon in human medicine. Approximately 50% of perforating ocular injuries in canines have lenticular involvement. Treatment choices include conservative management and surgical options. Retained intra-lenticular foreign body with delayed removal has not been reported in animals. Case Description: A 3-year-old male neutered Lurcher presented with right-sided ocular discomfort and a sealed full-thickness corneal perforation. The full ophthalmic examination could not be performed at the initial presentation due to miosis. Recrudescence of anterior uveitis was seen post-drug cessation. Re-evaluation of the eye with a mydriatic pupil revealed an intra-lenticular foreign body. Surgical removal via phacoemulsification was performed 8 weeks after the initial perforating injury. The eye remains visual, comfortable, and normotensive 50 months post-operatively. Conclusion: This is the first report of an encapsulated, retained intra-lenticular foreign body with delayed removal in a dog. Mydriasis and repeat examinations are of crucial importance when evaluating eyes post-perforation.


Asunto(s)
Enfermedades de los Perros , Cuerpos Extraños en el Ojo , Cristalino , Facoemulsificación , Humanos , Masculino , Perros , Animales , Cristalino/lesiones , Cristalino/cirugía , Cuerpos Extraños en el Ojo/diagnóstico , Cuerpos Extraños en el Ojo/cirugía , Cuerpos Extraños en el Ojo/veterinaria , Facoemulsificación/veterinaria , Enfermedades de los Perros/diagnóstico , Enfermedades de los Perros/cirugía
13.
J Vitreoretin Dis ; 7(6): 540-544, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37974922

RESUMEN

Purpose: To report an approach to explosive injuries with simultaneous, co-surgeon bilateral ruptured globe repair and pars plana vitrectomy for bilateral intraocular foreign bodies (IOFBs). Methods: A case and its findings were analyzed. Results: A 31-year-old man had bilateral vision loss after an air compressor malfunction that caused a high-pressure explosion to his face. An examination showed bilateral open-globe injuries and IOFBs, necessitating urgent repair. Given the risk for endophthalmitis and the need for expeditious repair, open-globe repair surgery was performed in both eyes simultaneously by co-surgeons followed by pars plana lensectomy, vitrectomy with IOFB removal, and silicone oil placement. The final visual acuity after bilateral scleral-fixated intraocular lens implantation was 20/20 OD and 20/25 OS. Conclusions: This case of bilateral open-globe injuries and IOFBs required expeditious repair with bilateral, simultaneous surgery that ultimately resulted in excellent visual outcomes. Simultaneous surgery may be an option for bilateral ocular trauma.

14.
J Vitreoretin Dis ; 7(6): 536-539, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38022792

RESUMEN

Purpose: To describe a novel surgical approach to treat traumatic posterior perforating injuries. Methods: A case and its findings were analyzed. Results: A 21-year-old man presented with bilateral intraocular foreign bodies that were sustained while hammering a metal railway pin. In the left eye, the foreign body was embedded in the posterior scleral wall, resulting in a 2 mm × 6 mm posterior perforation and partial retinal detachment. Silicone oil tamponade could optimize the chances for retinal reattachment; however, there was concern that the silicone oil would migrate through the posterior defect and into the orbit. Therefore, the perforation site was filled using a 3-layer plug consisting of donor sclera, human amniotic membrane, and fibrin glue. The silicone oil was successfully maintained within the globe; however, the final visual acuity was limited due to proliferative vitreoretinopathy. Conclusions: The efficacy and safety of the 3-layer plug technique should be further validated in similar cases.

15.
Heliyon ; 9(10): e20640, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37842556

RESUMEN

Introduction: Retained intraocular foreign body (IOFB) remains an important cause of acquired visual impairment. The visual prognosis following treatments for eyes with retained IOFB was observed to be distinct from other mechanisms of open globe injury due to the specific nature and associated circumstances. This study evaluated the risk behaviors, visual results, and predictive values of Ocular Trauma Score (OTS) in determining visual outcomes in patients with IOFB that were not related to terrorism. Methods: Medical records of patients who underwent surgical interventions between January 2015 and December 2020 were retrospectively reviewed. Results: A total of one hundred and sixty-one patients (162 eyes) were recruited. The patients had a mean (standard deviation) age of 47.6 (14.0) years with working male predominance (93.2%). The majority of patients were injured by activities related to grass trimming (63.4%) and metallic objects were the main materials causing injuries (75.7%). Following treatments, the proportion of eyes having vision worse than 20/400 decreased from 126 eyes (77.8%) to 55 eyes (33.9%) at final visit. Ocular trauma score (OTS) had a high potential prediction for final vision in eyes in OTS categories 4 and 5. However, the discordance of final visual acuity distribution was observed in some subgroups of eyes in OTS categories 1 to 3. Conclusion: This study highlights the significance of IOFB related eye injuries in a tertiary care setting. Decision making on treatments should be carefully considered, particularly in eyes in lower OTS categories, in light of a rise in the proportion of patients who experience improved vision after IOFB removal.

16.
Am J Ophthalmol Case Rep ; 32: 101917, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37680307

RESUMEN

Purpose: To describe the novel application of a urological instrument, the nitinol stone basket, in the removal of a retained intraocular foreign body (IOFB). Observations: This is a retrospective case series describing two eyes of two patients presenting with metallic IOFBs after hammering metal-on-metal. Both patients underwent 23-gauge pars plana vitrectomy (PPV) and successful IOFB extraction using the NCircle® Nitinol Tipless Stone Extractor. There were no intraoperative or post-surgical complications. Both patients demonstrated improvement in vision, with most recent postoperative visual acuities of 20/40 and 20/60. Conclusions and importance: The nitinol stone basket may be considered for removal of IOFBs, particularly larger IOFBs that are difficult to grasp with forceps. Our cases add to the literature showing favorable visual outcomes and few complications in the post-operative period using this technique.

17.
Taiwan J Ophthalmol ; 13(1): 114-116, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37252166

RESUMEN

A 38-year-old male with a history of trauma presented to us with pain and decreased vision in the left eye (LE). Previously, the patient had been diagnosed with hypopyon uveitis and was prescribed topical steroids. We performed slit-lamp examination of the LE and found exudates in the anterior chamber (AC) extending from 6 to 9 o'clock, along with circumciliary congestion and pigmented keratic precipitates. We made a diagnosis of infectious anterior hypopyon uveitis; however, all of its causes were ruled out upon the necessary investigations, which returned normal results. The patient was started on topical and oral antibiotics, and subsequently, there was complete hypopyon resolution. Five months later, he presented with similar complaints. An examination revealed a black elevated lesion in the AC at 8 o'clock suspicious of an intraocular foreign body (IOFB), along with 1 mm hypopyon. An X-ray orbit examination confirmed the IOFB presence, and the IOFB was surgically removed from the AC. Three weeks after this surgery, the patient presented with a recurrence of similar symptoms. The nasal pterygium adjacent to the location of the previously removed IOFB was inflamed with an underlying black elevated limbal nodule, which was determined to likely be a remnant of the IOFB in the subconjunctival space. Here, we report a case of penetrating IOFB that was initially detected in the AC. Its remnant extraocular component persisted in the subconjunctival space, and its incomplete removal led to recurrent inflammation.

18.
Diagnostics (Basel) ; 13(9)2023 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-37174966

RESUMEN

Intraocular foreign body injuries (IOFB) can lead to a number of intraocular pathologies; the visual results depend on the mechanism of the injury, the type of foreign body and the subsequent complications. The presence of intraocular cilia (eye lashes) following penetrating injury or surgical intervention is uncommon. In the present paper, we present a case of a 58-year-old woman with a history of eye trauma and a perforated corneal wound in the left eye that occurred 50 years ago. On the ophthalmological exam we noticed in the anterior chamber a straight linear extension, resembling cilia, extending behind the iris. The patient reports that it appeared during COVID-19 infection, after repeated episodes of coughing. After a follow-up period, we decided to remove the eyelash; 24 h after surgery, the patient complained of severe eye pain. Intraocular pressure (IOP) in LE was 54 mmHg. The slit-lamp examination showed perikeratic congestion, corneal edema and mydriasis. Eye hypotensive treatment was started immediately and the patient's general condition slightly improved. Intraocular cilia can be tolerated for many years without causing any ocular reaction. The decision for surgical intervention must be taken according to the individual needs of the patient and his ocular characteristics with careful pre- and post-operative follow up.

19.
Cureus ; 15(4): e37819, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37214081

RESUMEN

We describe a case where the patient presented to the emergency department (ED) with ocular irritation in the right eye with concomitant blurry vision that had been persistent for a week. The cause of this patient's ocular irritation and worsening visual acuity was determined to be a retained foreign body of the limbus. The foreign body had been in the patient's eye for about four months before he began to experience these symptoms. The four-month duration was established based on initial symptoms and a prior ED visit with no noted eye injury or foreign body detection, as well as the degree of overlying epithelization. This case highlights the importance of obtaining a thorough history and physical examination while emphasizing the high index of suspicion needed for translucent foreign bodies. Here, an inert foreign body erupted four months after injury. Additionally, this case stresses the importance of transition of care for ophthalmologic conditions. Consideration of any social determinants of health that could prevent as an example.

20.
Indian J Ophthalmol ; 71(5): 2324, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37203010

RESUMEN

Background: A patient with a retained intraocular metallic foreign body post-trauma was taken up for vitrectomy and intraocular foreign body removal. Unfortunately, the intraocular magnet was not available at the moment on the table! How a little bit of creativity and innovative thought helped us tide over this crisis is the content of this video. Purpose: To demonstrate magnetization of a metallic surgical instrument for temporary use in the event of unavailability of the intraocular magnet for intraocular foreign body removal. Synopsis: A ferromagnetic substance can be magnetized temporarily using an existing magnet. We obtained a general-purpose magnet and wrapped it in sterile plastic, using which we magnetized normal intraocular forceps and a Micro Vitreo Retinal (MVR) blade by giving about 20-30 strokes over the magnet in a single direction. This aligned the magnetic domains in the metal in a parallel fashion. These Do It Yourself (DIY)- magnetic instruments were then effectively utilized to remove the metallic intraocular foreign body. Highlights: The video showcases effectively harnessing the available resources and tiding over the dearth of a necessary instrument, with the right use of an innovative idea and some creativity!. Video link: https://youtu.be/QtRC-AK5FLU.


Asunto(s)
Cuerpos Extraños en el Ojo , Lesiones Oculares Penetrantes , Humanos , Vitrectomía , Retina , Instrumentos Quirúrgicos , Cuerpos Extraños en el Ojo/diagnóstico , Cuerpos Extraños en el Ojo/cirugía , Lesiones Oculares Penetrantes/diagnóstico , Lesiones Oculares Penetrantes/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...