RESUMEN
To improve the understanding of failure mechanisms and behaviour of hard rock tunnel linings, local load conditions were experimentally simulated and monitored using a comprehensive set of sensors and imaging techniques. The data includes measurements from distributed optical fiber sensors (DOFS), high-resolution cameras, load cells, pressure cells and LVDTs. Two types of loads were examined: rock block load and bond loss combined with a distributed load over the area of lost bond. The experiments replicated these conditions and were conducted in a laboratory setting where the shotcrete and substrate rock were substituted by cast fiber reinforced concrete (FRC) and cast concrete, respectively. To facilitate the loads, concrete cones were cast into the substrate concrete and pushed through the FRC top layer with a hydraulic jack to mimic rock block loads. To simulate the bond loss and the associated distributed load, lifting bags were installed and inflated between the FRC layer and substrate cast concrete. All specimens were monitored using DOFS embedded in two perpendicular directions and in two layers in the top FRC layer. In addition, the hydraulic jack was instrumented with LVDTs and load cells to measure displacement and load, and the pressure in the lifting bags was monitored using a pressure cell. Two cameras continuously photographed the top surface of the FRC layer, which had been painted with a speckle pattern, during the testing and the pictures can be used for digital image correlation (DIC). Lastly, each specimen was scanned with a 3D scanner prior to and after testing of the specimen.
RESUMEN
Optical fiber tapers have been widely proposed and demonstrated as reliable optical fiber structures for sensing, lasers, and supercontinuum generation applications. This paper proposes an innovative approach to fabricating optical fiber tapers using plasma as the heat source. From our literature review, and to the best of our knowledge, this is the first time that plasma has been used as the heat source for producing optical fiber tapers. The system is not intricate and simple to replicate. Moreover, the elements involved make this machine attractive to research groups devoted to optical fibers. The setup consistently generates robust biconical optical fiber tapers. A typical waist of â¼8 µm and taper lengths ranging from 3 to 15 mm are achieved. Our results showed tapers with interference fringes up to 12 dB, from 1465 nm to 1599 nm. Furthermore, the statistical evaluation presented demonstrates a good level of reproducibility in our tapering process.
RESUMEN
Over the past decade, distributed acoustic sensing has been utilized for structural health monitoring in various applications, owing to its continuous measurement capability in both time and space and its ability to deliver extensive data on the conditions of large structures using just a single optical cable. This work aims to evaluate the performance of distributed acoustic sensing for monitoring a multilayer structure on a laboratory scale. The proposed structure comprises four layers: a medium-density fiberboard and three rigid polyurethane foam slabs. Three different damages were emulated in the structure: two in the first layer of rigid polyurethane foam and another in the medium-density fiberboard layer. The results include the detection of the mechanical wave, comparing the response with point sensors used for reference, and evaluating how the measured signal behaves in time and frequency in the face of different damages in the multilayer structure. The tests demonstrate that evaluating signals in both time and frequency domains presents different characteristics for each condition analyzed. The supervised support vector machine classifier was used to automate the classification of these damages, achieving an accuracy of 93%. The combination of distributed acoustic sensing with this learning algorithm creates the condition for developing a smart tool for monitoring multilayer structures.
RESUMEN
This article presents a comprehensive study on the impact of irradiation optical fiber cores with a femtosecond-pulsed laser, operating at a wavelength of 1030 nm, on the signal amplitude in Rayleigh scattering-based optical frequency domain reflectometry (OFDR). The experimental study involves two fibers with significantly different levels of germanium doping: the standard single-mode fiber (SMF-28) and the ultra-high numerical aperture fiber (UHNA7). The research findings reveal distinct characteristics of reflected and scattered light amplitudes as a function of pulse energy. Although different amplitude changes are observed for the examined fibers, both can yield an enhancement of amplitude. The paper further investigates the effect of fiber Bragg grating inscription on the overall amplitude of reflected light. The insights gained from this study could be beneficial for controlling the enhancement of light scattering amplitude in fibers with low or high levels of germanium doping.
RESUMEN
To facilitate the sensor fabrication and sensing operation in microstructured optical fiber-based surface plasmon resonance (SPR) sensors for high refractive index (RI) detection, we propose a special hollow fiber-based SPR sensor that comprises an opening on its body side and a thin gold layer coated on its outer surface. The analyte is able to flow into the hollow core through the side-opening to form new fiber core, with the Gaussian-like mode propagating in it. We investigate the sensing performance of the proposed sensor in a higher RI range of 1.48 to 1.54 at two feasible schemes: one is to only fill the fiber core with analyte (Scheme A), and the other is to directly immerse the sensor in the analyte (Scheme B). The results demonstrate that our sensor exhibits higher wavelength sensitivity at Scheme A with a maximum wavelength sensitivity of 12,320 nm/RIU, while a greater amplitude sensitivity was found at Scheme B with a maximum amplitude sensitivity of 1146 RIU-1. Our proposed sensor features the advantages of simple fabrication, flexible operation, easy analyte filling and replacing, enhanced real-time detection capabilities, high RI detection, and very high wavelength sensitivity and amplitude sensitivity, which makes it more competitive in SPR sensing applications.
RESUMEN
A novel approach to the development of Distributed Temperature-Sensing (DTS) systems based on Raman Scattering in Multimode optical fibers operating at around 800 nm is presented, focusing on applications requiring temperature profile measurement in the range of a few hundreds of meters. In contrast to the standard Raman DTS systems, which aim to shorten the pulse space width as much as possible to improve the precision of measurement, the novel approach studied in this work is based on the use of pulses with a space width that is approximately equal to the distance covered by the fiber under test. The proposed technique relies on numerical post-processing to obtain the temperature profile measurement with a precision of about ±3 °C and a spatial resolution of 8 m, due to the transaction phases of the optical pulses. This solution simplifies the electronic circuit development, also minimizing the required laser peak power needed compared to the typical narrow pulse techniques.
RESUMEN
In recent years, soft robotic sensors have rapidly advanced to endow robots with the ability to interact with the external environment. Here, we propose a polymer optical fiber (POF) sensor with sensitive and stable detection performance for strain, bending, twisting, and pressing. Thus, we can map the real-time output light intensity of POF sensors to the spatial morphology of the elastomer. By leveraging the intrinsic correlations of neighboring sensors and machine learning algorithms, we realize the spatially resolved detection of the pressing and multi-dimensional deformation of elastomers. Specifically, the developed intelligent sensing system can effectively recognize the two-dimensional indentation position with a prediction accuracy as large as ~99.17%. The average prediction accuracy of combined strain and twist is ~98.4% using the random forest algorithm. In addition, we demonstrate an integrated intelligent glove for the recognition of hand gestures with a high recognition accuracy of 99.38%. Our work holds promise for applications in soft robots for interactive tasks in complex environments, providing robots with multidimensional proprioceptive perception. And it also can be applied in smart wearable sensing, human prosthetics, and human-machine interaction interfaces.
RESUMEN
We propose an air gap fiber Bragg grating (g-FBG) sensor that can measure strain and temperature simultaneously. The sensor is made by aligning two fiber Bragg gratings (FBGs), and an air gap exists between these two sub-gratings. This sensor's architecture allows it to form a spectrum with phase-shifted fiber Bragg grating (PSFBG) spectroscopy and Fabry-Perot interference (FPI) spectroscopy. Since the sensitivity of PSFBG and FPI spectra is different for strain and temperature, it is possible to measure both strain and temperature by measuring one of the reflected dips of PSFBG and the interference dip of FPI. The experimental results show that the strain sensitivity is about 11.95 pm/µÎµ via the dip wavelength detection of FPI, and the temperature sensitivity is about 9.64 pm/°C via the dip wavelength detection of PSFBG. The g-FBG sensor demonstrates a resolution of approximately ±3.7 µÎµ within the strain range of 0 to 1000 µÎµ and about ±0.6 °C within the temperature range of 25 °C to 120 °C. The proposed g-FBG sensor, characterized by its simple structure, compact size, and cost-effectiveness, exhibits significant potential in the field of multi-parameter measurements.
RESUMEN
This paper describes design, theoretical analysis, and experimental evaluation of a π-Phase-Shifted Fiber Bragg Grating (π-PSFBG) inscribed in the standard telecom fiber for slow light generation. At first, the grating was designed for its use in the reflection mode with a central wavelength of 1552 nm and a pass band width of less than 100 pm. The impact of fabrication imperfections was experimentally investigated and compared to model predictions. The optical spectra obtained experimentally show that the spectral region used for slow light generation is narrower (less than 10 pm), thus allowing for too-low levels of slow light optical-output power. In the next step, the optimization of the grating design was conducted to account for fabrication errors, to improve the grating's spectral behavior and its temporal performance, and to widen the spectral interval for slow light generation in the grating's transmission mode. The targeted central wavelength was 1553 nm. The π-PSFBG was then commercially fabricated, and the achieved parameters were experimentally investigated. For the region of (1551-1554) nm, a 15-fold increase in the grating's pass band width was achieved. We have shown that a pair of retarded optical pulses were generated. The measured group delay was found to be ~10.5 ps (compared to 19 ps predicted by the model). The π-PSFBG operating in its transmission mode has the potential to operate as tunable delay line for applications in RF photonics, ultra-fast signal processing, and optical communications, where tunable high precision delay lines are highly desirable. The π-PSFBG can be designed and used for the generation of variable group delays from tens to hundreds of ps, depending on application needs.
RESUMEN
Muscle fatigue is defined as a reduced ability to maintain maximal strength during voluntary contraction. It is associated with musculoskeletal disorders that affect workers performing repetitive activities, affecting their performance and well-being. Although electromyography remains the gold standard for measuring muscle fatigue, its limitations in long-term work motivate the use of wearable devices. This article proposes a computational model for estimating muscle fatigue using wearable and non-invasive devices, such as Optical Fiber Sensors (OFSs) and Inertial Measurement Units (IMUs) along the subjective Borg scale. Electromyography (EMG) sensors are used to observe their importance in estimating muscle fatigue and comparing performance in different sensor combinations. This study involves 30 subjects performing a repetitive lifting activity with their dominant arm until reaching muscle fatigue. Muscle activity, elbow angles, and angular and linear velocities, among others, are measured to extract multiple features. Different machine learning algorithms obtain a model that estimates three fatigue states (low, moderate and high). Results showed that between the machine learning classifiers, the LightGBM presented an accuracy of 96.2% in the classification task using all of the sensors with 33 features and 95.4% using only OFS and IMU sensors with 13 features. This demonstrates that elbow angles, wrist velocities, acceleration variations, and compensatory neck movements are essential for estimating muscle fatigue. In conclusion, the resulting model can be used to estimate fatigue during heavy lifting in work environments, having the potential to monitor and prevent muscle fatigue during long working shifts.
Asunto(s)
Extremidad Superior , Dispositivos Electrónicos Vestibles , Humanos , Electromiografía/métodos , Codo , Fatiga Muscular , Fenómenos BiomecánicosRESUMEN
In this paper, a tapered fiber bioprobe based on Mach-Zehnder interference (MZI) is proposed. To retain the highly sensitive straight-tapered fiber MZI sensing structure, we designed a U-shaped transmission fiber structure for the collection of optical sensing signals to achieve a miniature-insert-probe design. The spectrum responses from the conventional straight-tapered fiber MZI sensor and our proposed sensor were compared and analyzed, and experimental results showed that our proposed sensor not only has the same sensing capability as the straight-tapered fiber sensor, but also has the advantages of being flexible, convenient, and less liquid-consuming, which are attributed to the inserted probe design. The tapered fiber bioprobe obtained a sensitivity of 1611.27 nm/RIU in the refractive index detection range of 1.3326-1.3414. Finally, immunoassays for different concentrations of human immunoglobulin G were achieved with the tapered fiber bioprobe through surface functionalization, and the detection limit was 45 ng/mL. Our tapered fiber bioprobe has the insert-probe advantages of simpleness, convenience, and fast operation. Simultaneously, it is low-cost, highly sensitive, and has a low detection limit, which means it has potential applications in immunoassays and early medical diagnosis.
Asunto(s)
Técnicas Biosensibles , Fibras Ópticas , Humanos , Interferometría/métodos , Refractometría/métodos , InmunoensayoRESUMEN
This study investigated the use of distributed optical fiber sensing to measure temperature and strain during thermomechanical processes in printed circuit board (PCB) manufacturing. An optical fiber (OF) was bonded to a PCB for simultaneous measurement of temperature and strain. Optical frequency-domain reflectometry was used to interrogate the fiber optic sensor. As the optical fiber is sensitive to both temperature and strain, a demodulation technique is required to separate both effects. Several demodulation techniques were compared to find the best one, highlighting their main limitations. The importance of good estimations of the temperature sensitivity coefficient of the OF and the coefficient of thermal expansion of the PCB was highlighted for accurate results. Furthermore, the temperature sensitivity of the bonded OF should not be neglected for accurate estimations of strains. The two-sensor combination model provided the best results, with a 2.3% error of temperature values and expected strain values. Based on this decoupling model, a methodology for measuring strain and temperature variations in PCB thermomechanical processes using a single and simple OF was developed and tested, and then applied to a trial in an industrial environment using a dynamic oven with similar characteristics to those of a reflow oven. This approach allows the measurement of the temperature profile on the PCB during oven travel and its strain state (warpage).
RESUMEN
We demonstrate fiber optic sensors with temperature compensation for the accurate measurement of ethanol concentration in aqueous solutions. The device consists of two photonic crystal (PhC) fiber-tip sensors: one measures the ethanol concentration via refractive index (RI) changes and the other one is isolated from the liquid for the independent measurement of temperature. The probes utilize an optimized PhC design providing a Lorentzian-like, polarization-independent response, enabling a very low imprecision (pm-level) in the wavelength determination. By combining the information from the two probes, it is possible to compensate for the effect that the temperature has on the concentration measurement, obtaining more accurate estimations of the ethanol concentration in a broad range of temperatures. We demonstrate the simultaneous and single-point measurements of temperature and ethanol concentration in water, with sensitivities of 19 pm/°C and â¼53 pm/%, in the ranges of 25 °C to 55 °C and 0 to 50% (at 25 °C), respectively. Moreover, a maximum error of 1.1% in the concentration measurement, with a standard deviation of ≤0.8%, was obtained in the entire temperature range after compensating for the effect of temperature. A limit of detection as low as 0.08% was demonstrated for the concentration measurement in temperature-stable conditions.
RESUMEN
Wearable optical fiber sensors have great potential for development in medical monitoring. With the increasing demand for compactness, comfort, accuracy, and other features in new medical monitoring devices, the development of wearable optical fiber sensors is increasingly meeting these requirements. This paper reviews the latest evolution of wearable optical fiber sensors in the medical field. Three types of wearable optical fiber sensors are analyzed: wearable optical fiber sensors based on Fiber Bragg grating, wearable optical fiber sensors based on light intensity changes, and wearable optical fiber sensors based on Fabry-Perot interferometry. The innovation of wearable optical fiber sensors in respiration and joint monitoring is introduced in detail, and the main principles of three kinds of wearable optical fiber sensors are summarized. In addition, we discuss their advantages, limitations, directions to improve accuracy and the challenges they face. We also look forward to future development prospects, such as the combination of wireless networks which will change how medical services are provided. Wearable optical fiber sensors offer a viable technology for prospective continuous medical surveillance and will change future medical benefits.
Asunto(s)
Fibras Ópticas , Dispositivos Electrónicos Vestibles , Estudios Prospectivos , Luz , InterferometríaRESUMEN
The structural dynamic response of hydraulic turbines needs to be continuously monitored to predict incipient failures and avoid catastrophic breakdowns. Current methods based on traditional off-board vibration sensors mounted on fixed components do not permit inferring loads induced on rotating parts with enough accuracy. Therefore, the present paper assesses the performance of fiber Bragg grating sensors to measure the vibrations induced on a rotating shaft-disc assembly partially submerged in water resembling a hydraulic turbine rotor. An innovative mounting procedure for installing the sensors is developed and tested, which consists of machining a thin groove along a shaft line to embed a fiber-optic array that can pass through the bearings. At the top of the shaft, a rotary joint is used to extract, in real time, the signals to the interrogator. The shaft strain distribution is measured with high spatial resolution at different rotating speeds in air and water. From this, the natural frequencies, damping ratios, and their associated mode shapes are quantified at different operating conditions. Additionally, the change induced in the modes of vibration by the rotation effects is well captured. All in all, these results validate the suitability of this new fiber-optic technology for such applications and its overall better performance in terms of sensitivity and spatial resolution relative to traditional equipment. The next steps will consist of testing this new sensing technology in actual full-scale hydraulic turbines.
RESUMEN
We present a novel method for the online measurement of multi-point opening distances of midpalatal sutures during a rapid palatal expansion (RPE) using fiber optic Fabry-Perot (F-P) sensors. The sensor consists of an optical fiber with a cut flat end face and an optical reflector, which are implanted into the palatal base structure of an expander and is capable of measuring the precise distance between two optical reflective surfaces. As a demonstration, a 3D-printed skull model containing the maxilla and zygomaticomaxillary complex (ZMC) was produced and a miniscrew-assisted rapid palatal expander (MARPE) with two guide rods was used to generate the midpalatal suture expansion. The reflected spectrums of the sensors were used to dynamically extract cavity length information for full process monitoring of expansion. The dynamic opening of the midpalatal suture during the gradual activation of the expander was measured, and a displacement resolution of 2.5 µm was demonstrated. The angle of expansion was derived and the results suggested that the midpalatal suture was opened with a slight V-type expansion of 0.03 rad at the first loading and subsequently expanded in parallel. This finding might be useful for understanding the mechanical mechanisms that lead to different types of expansion. The use of a fiber optic sensor for mounting the rapid palatal expander facilitates biomechanical studies and experimental and clinical evaluation of the effects of RPE.
Asunto(s)
Técnica de Expansión Palatina , Cráneo , Cráneo/diagnóstico por imagen , Cabeza , Tecnología de Fibra Óptica , Impresión TridimensionalRESUMEN
This paper presents a novel probabilistic machine learning (PML) framework to estimate the Brillouin frequency shift (BFS) from both Brillouin gain and phase spectra of a vector Brillouin optical time-domain analysis (VBOTDA). The PML framework is used to predict the Brillouin frequency shift (BFS) along the fiber and to assess its predictive uncertainty. We compare the predictions obtained from the proposed PML model with a conventional curve fitting method and evaluate the BFS uncertainty and data processing time for both methods. The proposed method is demonstrated using two BOTDA systems: (i) a BOTDA system with a 10 km sensing fiber and (ii) a vector BOTDA with a 25 km sensing fiber. The PML framework provides a pathway to enhance the VBOTDA system performance.
Asunto(s)
Aprendizaje Automático , Dispositivos Ópticos , Modelos Estadísticos , Procesamiento de Señales Asistido por Computador , IncertidumbreRESUMEN
In recent decades, the Surface Plasmon Resonance (SPR) phenomenon has been utilized as an underlying technique in a broad range of application fields. Herein, a new measuring strategy which harnesses the SPR technique in a way that is different from the classical methodology was explored by taking advantage of the characteristics of multimode waveguides, such as plastic optical fibers (POFs) or hetero-core fibers. The sensor systems based on this innovative sensing approach were designed, fabricated, and investigated to assess their ability to measure various physical features, such as magnetic field, temperature, force, and volume, and to realize chemical sensors. In more detail, a sensitive patch of fiber was used in series with a multimodal waveguide where the SPR took place, to alter the mode profile of the light at the input of the waveguide itself. In fact, when the changes of the physical feature of interest acted on the sensitive patch, a variation of the incident angles of the light launched in the multimodal waveguide occurred, and, as a consequence, a shift in resonance wavelength took place. The proposed approach permitted the separation of the measurand interaction zone and the SPR zone. This meant that the SPR zone could be realized only with a buffer layer and a metallic film, thus optimizing the total thickness of the layers for the best sensitivity, regardless of the measurand type. The proposed review aims to summarize the capabilities of this innovative sensing approach to realize several types of sensors for different application fields, showing the high performances obtained by exploiting a simple production process and an easy experimental setup.
Asunto(s)
Fibras Ópticas , Resonancia por Plasmón de Superficie , Diseño de Equipo , Resonancia por Plasmón de Superficie/métodos , PlásticosRESUMEN
Cerium-doped-silica glasses are widely used as ionizing radiation sensing materials. However, their response needs to be characterized as a function of measurement temperature for application in various environments, such as in vivo dosimetry, space and particle accelerators. In this paper, the temperature effect on the radioluminescence (RL) response of Cerium-doped glassy rods was investigated in the 193-353 K range under different X-ray dose rates. The doped silica rods were prepared using the sol-gel technique and spliced into an optical fiber to guide the RL signal to a detector. Then, the experimental RL levels and kinetics measurements during and after irradiation were compared with their simulation counterparts. This simulation is based on a standard system of coupled non-linear differential equations to describe the processes of electron-hole pairs generation, trapping-detrapping and recombination in order to shed light on the temperature effect on the RL signal dynamics and intensity.
RESUMEN
Optical fiber sensors (OFSs) represent an efficient sensing solution in various structural health monitoring (SHM) applications. However, a well-defined methodology is still missing to quantify their damage detection performance, preventing their certification and full deployment in SHM. In a recent study, the authors proposed an experimental methodology to qualify distributed OFSs using the concept of probability of detection (POD). Nevertheless, POD curves require considerable testing, which is often not feasible. This study takes a step forward, presenting a model-assisted POD (MAPOD) approach for the first time applied to distributed OFSs (DOFSs). The new MAPOD framework applied to DOFSs is validated through previous experimental results, considering the mode I delamination monitoring of a double-cantilever beam (DCB) specimen under quasi-static loading conditions. The results show how strain transfer, loading conditions, human factors, interrogator resolution, and noise can alter the damage detection capabilities of DOFSs. This MAPOD approach represents a tool to study the effects of varying environmental and operational conditions on SHM systems based on DOFSs and for the design optimization of the monitoring system.