Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(11)2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38894159

RESUMEN

Tension members are key members that maintain stability and improve the strength of structures such as cable-stayed bridges, PSC structures, and slopes. Their application has recently been expanded to new fields such as mooring lines in subsea structures and aerospace fields. However, the tensile strength of the tension members can be abnormal owing to various risk factors that may lead to the collapse of the entire structure. Therefore, continuous tension monitoring is necessary to ensure structural safety. In this study, an improved elasto-magnetic (E/M) sensor was used to monitor tension force using a nondestructive method. General E/M sensors have limitations that make it difficult to apply them to operating tension members owing to their solenoid structure, which requires field winding. To overcome this problem, the magnetization part of the E/M sensor was improved to a yoke-type sensor, which was used in this study. For the development of the sensors, the numerical design and magnetization performance verification of the sensor were performed through eddy current solution-type simulations using ANSYS Maxwell. Using the manufactured yoke-type E/M sensor, the induced voltage signals according to the tension force of the specimen increasing from 0 to 10 tons at 1-ton intervals were repeatedly measured using DAQ with wireless communication. The measured signals were indexed using peak-to-peak value of induced voltages and used to analyze the signal change patterns as the tension increased. Finally, the analyzed results were compared with those of a solenoid-type E/M sensor to confirm the same pattern. Therefore, it was confirmed that the tension force of a tension member can be estimated using the proposed yoke-type E/M sensor. This is expected to become an effective tension monitoring technology through performance optimization and usability verification studies for each target tension member in the future.

2.
Sci Rep ; 14(1): 9969, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38693220

RESUMEN

This paper proposes a prediction method for the tension force of support ropes in flexible rockfall barriers. The method is based on two full-scale model tests with an impact energy of 3000 kJ, as well as 36 set numerical models featuring varying lengths and impact energies. From the results of full scale tests and numerical models, it is inferred that the tension force at the end of the support rope is significantly less than that at the point of impact, exhibiting an approximate Gaussian attenuation distribution with propagation distance. To account for the attenuation of tensile forces in support ropes, a tensile attenuation coefficient is defined. Through comparative analysis of data obtained from 36 models with varying impact energies and propagation distances, the average attenuation coefficient for the upper support rope is determined to be approximately 0.7, while the average coefficient for the lower support rope is around 0.8. Utilizing the least squares method, a prediction method for the tension force of support ropes in flexible rockfall barriers is established. This method takes into account both the propagation distance and impact energy, enabling accurate predictions of the tensile behavior of the ropes under different conditions. This prediction model provides valuable insights for engineers in the design and optimization of these flexible barriers for rockfall mitigation.

3.
Int J Mol Sci ; 25(6)2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38542515

RESUMEN

High-grade hemorrhoids are usually recommended to receive operational treatments. However, these traditional surgeries are associated with severe postoperative pain. A procedure for prolapse and hemorrhoids (PPH), a circular staple device, has been developed to improve short-term outcomes, including reducing the severity of postoperative pain. PPH, compared to conventional surgery, has been associated with the incidence of anatomical anal stenosis. The causes of stenosis after PPH are not yet clear. We first analyzed the complications of our patients with PPH, and then developed a rat model to verify the tension force of PPH using Hematoxylin-eosin, Masson's trichrome, immunohistochemistry, and immunofluorescence staining. Our clinical data showed that PPH significantly improved postoperative pain, but that it resulted in higher incidences of complications, including anal stenosis, than hemorrhoidectomy. We simulated the status of PPH and developed a rat model to verify PPH's tension force, including the scarring area and the deposition of proinflammatory factors, angiogenic factors, and fibrotic factors. The tension wound histological data showed more extensive granulation tissue and inflammatory cell infiltration and a thicker epidermis than the control group on day 12 post-operation and tension treatment. In addition to IL-1ß and IL-10 cytokines on day 3 and IL-1ß, IL-6, and IL-10 cytokines on day 12 post-operation in the tension group, two angiogenic factors, CD31 and VEGF-A, were found to have a more significant expression on day 7 post-operation in the tension group. The mean scar area was larger and the distribution of fibrotic proteins (collagen 1, α-SMA, CTGF, and MMP2) in the tension group was significantly broader than in the control on day 12 post-operation and tension treatment. Based on the findings of our animal model, the development of a lesser tensile force for PPH to decrease the deposition of proinflammatory factors, angiogenic factors, and fibrotic factors is urgently required.


Asunto(s)
Hemorroides , Humanos , Animales , Ratas , Hemorroides/cirugía , Hemorroides/complicaciones , Estudios Retrospectivos , Interleucina-10 , Constricción Patológica/complicaciones , Prolapso , Dolor Postoperatorio/complicaciones , Resultado del Tratamiento
4.
Front Bioeng Biotechnol ; 11: 1297507, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38116197

RESUMEN

Introduction: Currently, cannulated screws (CSs) and dynamic hip screws (DHSs) are widely used for the treatment of femoral neck fractures, but the postoperative complications associated with these internal fixations remain high. In response to this challenge, our team proposes a new approach involving triangular-supported fixation and the development of the proximal femoral bionic nail (PFBN). The primary objective of this study is to investigate the biomechanical differences among CSs, DHSs, and the PFBN in their capacity to stabilize femoral neck fractures. Methods: A normal proximal femur model was constructed according to the CT data of a normal healthy adult. A femoral neck fracture model was constructed and fixed with CSs, DHSs, and the PFBN to simulate the fracture fixation model. Abaqus 6.14 software was used to compare the biomechanical characters of the three fracture fixation models. Results: The maximum stresses and displacements of the normal proximal femur were 45.35 MPa and 2.83 mm, respectively. Under axial loading, the PFBN was more effective than DHSs and CSs in improving the stress concentration of the internal fixation and reducing the peak values of von Mises stress, maximum principal stress, and minimum principal stress. The PFBN fixation model exhibits superior overall and fracture section stability in comparison to both the DHS fixation model and the CS fixation model under axial loading. Notably, the maximum stress and peak displacement of the PFBN and bone were lower than those of the DHS and CS fixation models under bending and torsional loading. Conclusion: The PFBN shows considerable improvement in reducing stress concentration, propagating stress, and enhancing the overall stability in the femoral neck fracture fixation model compared to DHSs and CSs. These enhancements more closely correspond to the tissue structure and biomechanical characteristics of the proximal femur, demonstrating that the PFBN has great potential for therapeutic purposes in treating femoral neck fractures.

5.
Prog Orthod ; 24(1): 33, 2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37840086

RESUMEN

BACKGROUND: Renin-angiotensin system and its ACE2/Ang(1-7)/Mas receptor axis regulates skeletal response to multiple physiological and pathological conditions. Recent research suggested a vital role of Ang(1-7) in regulating alveolar bone metabolism and remodeling. In this context, this study evaluated the effects of the Ang(1-7)/Mas receptor axis on orthodontic tooth movement (OTM) and the alveolar bone response to mechanical load. METHODS: A coil spring was placed between the right maxillary first molar and the anterior tooth of Wistar rats to apply bidirectional mechanical force. Ang(1-7) with or without a specific Mas receptor antagonist (A779) was infused using subcutaneous osmotic pumps (200 and 400 ng/kg/min: respectively). Animals were killed after 5 and 14 days from the OTM procedure after the clinical evaluation of tooth movement and mobility. Morphometric analysis of alveolar bone structure was conducted using micro-CT and the histological picture was evaluated after H&E staining. Moreover, collagen fiber distribution was assessed using Picro-Sirius red stain. In addition, bone samples were collected from the pressure and tension sites around the anterior tooth for gene expression analysis. RESULTS: Ang(1-7) infusion suppressed the tooth movement and mobility after 14 days of the orthodontic force application. Additionally, Ang(1-7) infusion preserved the morphometric and histological structure of the alveolar bone at pressure and tension sides. These effects were abolished by adding A779 infusion. Collagen fiber distribution was dysregulated mainly by the A779 Mas receptor blockage. Ang(1-7) affected the bone formation, remodeling- and vascularity-related genes in the pressure and tension sides, suggesting a prominent suppression of osteoclastogenesis. Ang(1-7) also improved osteoblasts-related genes on the tension side, whereas the osteoclasts-related genes were augmented by A779 on the pressure side. CONCLUSION: Collectively, the activation of Ang(1-7)/Mas receptor axis appears to hinder tooth movement and regulates alveolar bone remodeling in response to mechanical force.


Asunto(s)
Proceso Alveolar , Técnicas de Movimiento Dental , Ratas , Animales , Ratas Wistar , Técnicas de Movimiento Dental/métodos , Proceso Alveolar/fisiología , Modelos Animales , Colágeno , Angiotensinas
6.
Biomater Adv ; 150: 213431, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37116456

RESUMEN

Biomechanical inputs are ubiquitously present in biological systems and are known to regulate various cell functions. In particular, neural cell development is sensitive to mechanical regulation, as these cells reside in one of the softest microenvironments in the body. To fully characterize and comprehend how mechanical force modulates early neuronal processes, we prepared substrates functionalized with DNA probes displaying integrin ligands, including cRGD and laminin, to quantify integrin-mediated molecular tension during neurite initiation in primary cortical neurons. Our live-cell imaging analysis reveals that integrin-mediated tension force is highly dynamic and distributed across the cell body, with the overall tension signal gradually increasing during neurite outgrowth. Notably, we detected a consistent level of mechanical force (amplitude = 4.7-12 piconewtons, pN) for cell integrin-ligand interactions. Further quantifications reveal that neurons exhibit faster cell spreading and neurite outgrowth upon interacting with ligands functionalized with 4.7 pN relative to 12 pN probes. These findings indicate that the magnitude of integrin-mediated mechanical feedback regulates neuronal activity during early neuritogenesis. Additionally, we observed that mechanical tension is correlated with calcium signaling, since inhibiting calcium influx substantially reduced mechanical tension. Thus, our findings support that the magnitude of integrin-mediated mechanical feedback regulates neuronal activity during early neuritogenesis and that mechanical force is an essential element complementing well-known biochemical regulatory mechanisms orchestrating the integrin activation machinery and controlled neurite outgrowth in cortical neurons.


Asunto(s)
Integrinas , Neuronas , Ligandos , Integrinas/genética , ADN , Proyección Neuronal
7.
Heliyon ; 9(2): e13236, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36798766

RESUMEN

Bone remodelling is the process of bone resorption and formation, necessary to maintain bone structure or for adaptation to new conditions. Mechanical loadings, such as exercise, weight bearing and orthodontic force, play important roles in bone remodelling. During the remodelling process, osteocytes play crucial roles as mechanosensors to regulate osteoblasts and osteoclasts. However, the precise molecular mechanisms by which the mechanical stimuli affect the function of osteocytes remain unclear. In the present study, we analysed viability, cell cycle distribution and gene expression pattern of murine osteocyte-like MLO-Y4 cells exposed to tension force (TF). Cells were subjected to TF with 18% elongation at 6 cycles/min for 24 h using Flexcer Strain Unit (FX-3000). We found that TF stimulation induced cell cycle arrest at G2/M phase but not cell death in MLO-Y4 cells. Differentially expressed genes (DEGs) between TF-stimulated and unstimulated cells were identified by microarray analysis, and a marked increase in glutathione-S-transferase α (GSTA) family gene expression was observed in TF-stimulated cells. Enrichment analysis for the DEGs revealed that Gene Ontology (GO) terms and Kyoto Encyclopedia Genes and Genomes (KEGG) pathways related to the stress response were significantly enriched among the upregulated genes following TF. Consistent with these results, the production of reactive oxygen species (ROS) was elevated in TF-stimulated cells. Activation of the tumour suppressor p53, and upregulation of its downstream target GADD45A, were also observed in the stimulated cells. As GADD45A has been implicated in the promotion of G2/M cell cycle arrest, these observations may suggest that TF stress leads to G2/M arrest at least in part in a p53-dependent manner.

8.
Adv Sci (Weinh) ; 9(31): e2203173, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36031407

RESUMEN

A recently developed synthetic retinoid abrogates proliferation and induces apoptosis of drug-resistant malignant-cancer-stem-cell-like cells. However, the underlying mechanisms of how the synthetic retinoid induces cancer-stem-cell-like cell tumor-repopulating cell (TRC) apoptosis are elusive. Here, it is shown that although the retinoid and conventional anticancer drugs cisplatin, all-trans retinoic acid, and tazarotene all inhibit cytoskeletal tension and decondense chromatin prior to inducing TRC apoptosis, half-maximal inhibitory concentration of the retinoid is 20-fold lower than those anticancer drugs. The synthetic retinoid induces retinoic acid receptor gamma (RARγ) translocation from the nucleus to the cytoplasm, leading to reduced RARγ binding to Cdc42 promoter and Cdc42 downregulation, which decreases filamentous-actin (F-actin) and inhibits cytoskeletal tension. Elevating F-actin or upregulating histone 3 lysine 9 trimethylation decreases retinoid-induced DNA damage and apoptosis of TRCs. The combinatorial treatment with a chromatin decondensation molecule and the retinoid inhibits tumor metastasis in mice more effectively than the synthetic retinoid alone. These findings suggest a strategy of lowering cell tension and decondensing chromatin to enhance DNA damage to abrogate metastasis of cancer-stem-cell-like cells with high efficacy.


Asunto(s)
Antineoplásicos , Neoplasias , Células Madre Neoplásicas , Retinoides , Drogas Sintéticas , Animales , Ratones , Actinas , Antineoplásicos/farmacología , Cromatina , Células Madre Neoplásicas/efectos de los fármacos , Retinoides/farmacología , Resistencia a Antineoplásicos
9.
Materials (Basel) ; 14(12)2021 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-34203620

RESUMEN

The analysis presented in this paper is focused on problems of bond strength as an overall bond quality parameter of industrial adhesives for structural anchoring. In the first part, the problem of bond strength as the most important parameter influencing the final anchor resistance to tension load is described. Further in the text, a new methodology of simplified testing of the strength parameters of adhesives is described. Special test specimens made from steel are repeatedly used in this methodology. Additionally, results of these tests on some new recipes for adhesive are presented. Especially, epoxy resins with special fillers, such as carbon fibres, carbon nanotubes or graphene, were tested. The use of these adhesives in temperatures close to zero degrees Celsius was also tested.

10.
Sensors (Basel) ; 19(1)2018 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-30583558

RESUMEN

Force changes in axially loaded members can be monitored by quantifying variations in impedance signatures. However, statistical damage metrics, which are not physically related to the axial load, often lead to difficulties in accurately estimating the amount of axial force changes. Inspired by the wearable technology, this study proposes a novel wearable piezoelectric interface that can be used to monitor and quantitatively estimate the force changes in axial members. Firstly, an impedance-based force estimation method was developed for axially loaded members. The estimation was based on the relationship between the axial force level and the peak frequencies of impedance signatures, which were obtained from the wearable piezoelectric interface. The estimation of the load transfer capability from the axial member to the wearable interface was found to be an important factor for the accurate prediction of axial force. Secondly, a prototype of the wearable piezoelectric interface was designed to be easily fitted into existing axial members. Finally, the feasibility of the proposed technique was established by assessing tension force changes in a numerical model of an axially loaded cylindrical member and a lab-scale model of a prestressed cable structure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...