1.
Clin Chem Lab Med ; 56(9): 1533-1541, 2018 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-29708876

RESUMEN

BACKGROUND: Urinary vanillylmandelic acid (VMA) and homovanillic acid (HVA) are biomarkers for the diagnosis and follow-up of neuroblastoma, whereas urinary 5-hydroxyindoleacetic acid (5-HIAA) is used to assess a carcinoid tumor. These analytes are conventionally analyzed in a single run by chromatography (LC) coupled with electrochemical detection (LC-ECD) using commercial kits. A rapid dilute-and-shoot LC tandem mass spectrometry (LC-MS/MS) assay was validated in order to replace the LC-ECD method and therefore improve analytical specificity and throughput. METHODS: Sample preparation was carried out by dilution of the urine sample with a solution containing the deuterated internal standards. The separation was achieved on an ultra-high pressure LC system with MS detection using a triple quadrupole mass spectrometer. The method was validated according to the current EMA and FDA guidelines. RESULTS: The full chromatographic run was achieved in 8 min. The method validation showed excellent linearity (r2>0.999 for all three analytes), precision (CV <15%), negligible matrix effect (recoveries >90%), low carryover (<1%) and LLOQ of 0.25, 0.4 and 0.4 µM for VMA, HVA and 5-HIAA, respectively. Deming fits and Bland-Altman analyses showed no significant differences between the values obtained between the two assays. CONCLUSIONS: The LC-MS/MS method proposed in this study is fast and robust, and the simple sample preparation saves time and avoids the additional costs of dedicated kits used for the LC-ECD assays by switching to LC-MS/MS. Additionally, the near-perfect correlation observed herein between both assays allows the previously established reference ranges to be maintained.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Ácido Homovanílico/orina , Ácido Hidroxiindolacético/orina , Espectrometría de Masas en Tándem/métodos , Ácido Vanilmandélico/orina , Biomarcadores/orina , Calibración , Tumor Carcinoide/diagnóstico , Cromatografía Líquida de Alta Presión/normas , Ácido Homovanílico/normas , Humanos , Ácido Hidroxiindolacético/normas , Límite de Detección , Neuroblastoma/diagnóstico , Espectrometría de Masas en Tándem/normas , Ácido Vanilmandélico/normas
2.
Clin Chem ; 36(1): 110-2, 1990 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-2153482

RESUMEN

This rapid fluorescence polarization immunoassay for urinary vanillylmandelic acid (VMA) involves use of our previously described antiserum and label and the program for 5-hydroxyindoleacetic acid in the Abbott TDx fluorimeter. Urine samples were measured directly, without pretreatment. The minimum detectable concentration was 0.3 mg/L, and the range of the standard curve was 0.3-200.0 mg/L. Precision, analytical recovery, and correlation of results with those by the Pisano method (Clin Chim Acta 1962;7:285-91) were all satisfactory. With this procedure one can determine the VMA concentration in 10 urine sample in 22 min. This is the first report of a clinical immunoassay for VMA and should greatly simplify screening for neural crest tumors.


Asunto(s)
Ácido Vanilmandélico/orina , Polarización de Fluorescencia , Humanos , Inmunoensayo , Tamizaje Masivo , Neoplasias de Células Germinales y Embrionarias/orina , Cresta Neural , Ácido Vanilmandélico/normas
3.
Ann Clin Biochem ; 23 ( Pt 4): 447-52, 1986 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-3021042

RESUMEN

A method is reported for the determination of 4-hydroxy-3-methoxymandelic acid (HMMA) by HPLC with electrochemical detection. The preparation of sample prior to HPLC has been studied and an efficient and selective extraction procedure described. Bonded-phase silica extraction columns and a vacuum manifold were used for the simple and rapid processing of batches of urine samples. Combining a reverse-phase C18 and an anion exchange column ensures selective isolation of HMMA. This simplified greatly the subsequent chromatography. The method was combined into a simple scheme for the routine analysis of urine HMMA, catecholamines and 5-hydroxyindole-3-acetic acid. The HPLC was standardised such that a single mobile phase was used with minor modification for each of the assays.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Ácido Vanilmandélico/orina , Cromatografía , Electroquímica , Estudios de Evaluación como Asunto , Humanos , Control de Calidad , Estándares de Referencia , Dióxido de Silicio , Ácido Vanilmandélico/normas