Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 321
Filtrar
1.
J Biomed Mater Res B Appl Biomater ; 111(4): 958-970, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36479954

RESUMEN

Biodegradable shape memory polymers provide unique regenerative medicine approaches in minimally invasive surgeries. Once heated, thermally responsive shape memory polymer devices can be compressed, programmed to fit within a small profile, delivered in the cold programmed state, and expanded when heated to body temperature. We have previously developed a biodegradable shape memory elastomer (SME), poly(glycerol dodecanedioate) (PGD), with transition temperatures near 37°C exhibiting nonlinear elastic properties like numerous soft tissues. Using SMEs in the clinic requires disinfection and sterilization methods that conserve physiochemical, thermomechanical, and shape recovery properties. We evaluated disinfection protocols using 70% ethanol and UV254 nm for research applications and ethylene oxide (EtO) gas sterilization for clinical applications. Samples disinfected with ethanol for 0.5 and 1 min showed no changes in physiochemical material properties, but after 15 min showed slower recovery rates than controls (p < .05). EtO sterilization at 54.4°C decreased transition temperatures and shape recovery rate compared to EtO sterilization at 37.8°C (p < .01) and controls (p < .05). Aging samples for 9 months in a vacuum desiccator significantly reduced shape recovery, and the recovery rate in EtO sterilized samples compared to controls (p < .001). Cytotoxicity testing (ISO-10993.5C:2012) revealed media extractions from EtO sterilized samples, sterilized at 37.8°C, and high-density polyethylene negative control samples exhibit lower cytotoxicity (IC50) than Ethanol 1 min, UV 2 h, and EtO 54.4°C. Cell viability of NIH3T3 fibroblasts on sterilized surfaces was equivalent on EtO 37.7°C, EtO 54.4°C and Ethanol sterilized substrates. Finally, chromogenic bacterial endotoxin testing showed endotoxin levels were below the FDA prescribed levels for devices contacting blood and lymphatic tissues for ethanol 1 min, UV 120 min, EtO 37.7°C, EtO 54.4°C. These findings outline various disinfection and sterilization processes for research and pre-clinical application and provide a pathway for developing custom sterilization cycles for the translation of biomedical devices utilizing PGD shape memory polymers.


Asunto(s)
Elastómeros , Glicerol , Animales , Ratones , Elastómeros/farmacología , Glicerol/farmacología , Células 3T3 NIH , Esterilización/métodos , Desinfección , Etanol , Óxido de Etileno/farmacología , Óxido de Etileno/química
2.
Dent Med Probl ; 59(3): 381-387, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36170599

RESUMEN

BACKGROUND: Extracted human teeth are used to simulate dental procedures and are essential for practical education and research studies. OBJECTIVES: The aim of this study was to evaluate the efficacy of different sterilization methods for extracted human roots and to assess the effects of these methods on dentin microhardness. MATERIAL AND METHODS: The crowns of 40 mandibular incisors were removed. The roots were sectioned at 10 mm and divided into 4 groups (n = 10 per group): G1 - no sterilization (control); G2 - microwave radiation (650 W, 5 min); G3 - ethylene oxide (288°C, 3 h); and G4 - autoclave (121°C, 15 min). The roots were immersed in brain heart infusion (BHI) and incubated at 37°C in variable oxygen atmospheres. After 14 days, the samples were assessed for turbidity. Three slices were obtained from each root, and indentations were made at 30, 60 and 120 µm from the root canal lumen. The microbiological data was analyzed with the Kruskal-Wallis test and Dunn's post-hoc test. Microhardness was evaluated by means of the twoway analysis of variance (ANOVA) and Tukey's test (p < 0.05). RESULTS: The roots submitted to autoclaving were 100% sterile, which differed from the other methods (p < 0.05); the control specimens had 0% sterility. For microhardness, significant differences were found between the methods, particularly for the apical third (68.06 ±12.50) (p < 0.05). CONCLUSIONS: Although all the evaluated techniques reduced dentin microhardness, autoclaving should be used as the most reliable method of sterilization of extracted dental roots.


Asunto(s)
Dentina , Desinfección , Desinfección/métodos , Óxido de Etileno/farmacología , Dureza , Humanos , Incisivo , Oxígeno/farmacología
3.
Macromol Biosci ; 22(6): e2200015, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35451564

RESUMEN

Composite fibrous materials are prepared from poly(ethylene oxide) (PEO) and beeswax (BW) by single-spinneret electrospinning using chloroform as a common solvent. The obtained fibers have core-sheath-like structure, as evidenced by the water contact angle values and corroborated by the results on the elemental composition of the fiber's surface determined by X-ray photoelectron spectroscopy (XPS) and by analyses with scanning electron microscopy of fibers before and after selective extraction of PEO or BW. Furthermore, the core-sheath-like structure is proven by transmission electron microscopy. This is attributed to self-assembly of BW molecules on the surface of the formed fibers driven by the incompatibility between PEO and BW. 5-Nitro-8-hydroxyquinoline (NQ) is embedded as a model drug with antibacterial, antifungal, and anticancer properties in the PEO/BW fibrous materials. XPS analyses reveal that NQ is present on the surface of the PEO/BW/NQ materials. Using a purposely designed cell for fixation of the fibrous materials the NQ release in phosphate buffer solution with рН 7.4 is followed. The new PEO/BW/NQ fibrous materials exhibit antibacterial activity against S. aureus and E. coli, antifungal effect against C. albicans, and selective anticancer activity against HeLa (human cervical adenocarcinoma cells) and SH-4 (human melanoma cells) cell lines.


Asunto(s)
Polietilenglicoles , Staphylococcus aureus , Antibacterianos/química , Antibacterianos/farmacología , Antifúngicos/farmacología , Escherichia coli , Óxido de Etileno/farmacología , Humanos , Polietilenglicoles/química , Ceras
4.
Regul Toxicol Pharmacol ; 129: 105113, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34974128

RESUMEN

The 'ethylene glycol ethers' (EGE) are a broad family of solvents and hydraulic fluids produced through the reaction of ethylene oxide and a monoalcohol. Certain EGE derived from methanol and ethanol are well known to cause toxicity to the testes and fetotoxicity and that this is caused by the common metabolites methoxy and ethoxyacetic acid, respectively. There have been numerous published claims that EGE fall into the category of 'endocrine disruptors' often without substantiated evidence. This review systematically evaluates all of the available and relevant in vitro and in vivo data across this family of substances using an approach based around the EFSA/ECHA 2018 guidance for the identification of endocrine disruptors. The conclusion reached is that there is no significant evidence to show that EGE target any endocrine organs or perturb endocrine pathways and that any toxicity that is seen occurs by non-endocrine modes of action.


Asunto(s)
Éteres de Etila/química , Éteres de Etila/farmacología , Óxido de Etileno/química , Óxido de Etileno/farmacología , Animales , Relación Dosis-Respuesta a Droga , Glándulas Endocrinas/efectos de los fármacos , Ambiente , Éteres de Etila/farmacocinética , Óxido de Etileno/farmacocinética , Hormonas Esteroides Gonadales/metabolismo , Humanos , Receptores de Estrógenos/efectos de los fármacos , Absorción Cutánea/fisiología
5.
Antimicrob Resist Infect Control ; 10(1): 83, 2021 05 29.
Artículo en Inglés | MEDLINE | ID: mdl-34051855

RESUMEN

BACKGROUND: With the current SARS-CoV-2 pandemic, many healthcare facilities are lacking a steady supply of masks worldwide. This emergency situation warrants the taking of extraordinary measures to minimize the negative health impact from an insufficient supply of masks. The decontamination, and reuse of healthcare workers' N95/FFP2 masks is a promising solution which needs to overcome several pitfalls to become a reality. AIM: The overall aim of this article is to provide the reader with a quick overview of the various methods for decontamination and the potential issues to be taken into account when deciding to reuse masks. Ultraviolet germicidal irradiation (UVGI), hydrogen peroxide, steam, ozone, ethylene oxide, dry heat and moist heat have all been methods studied in the context of the pandemic. The article first focuses on the logistical implementation of a decontamination system in its entirety, and then aims to summarize and analyze the different available methods for decontamination. METHODS: In order to have a clear understanding of the research that has already been done, we conducted a systematic literature review for the questions: what are the tested methods for decontaminating N95/FFP2 masks, and what impact do those methods have on the microbiological contamination and physical integrity of the masks? We used the results of a systematic review on the methods of microbiological decontamination of masks to make sure we covered all of the recommended methods for mask reuse. To this systematic review we added articles and studies relevant to the subject, but that were outside the limits of the systematic review. These include a number of studies that performed important fit and function tests on the masks but took their microbiological outcomes from the existing literature and were thus excluded from the systematic review, but useful for this paper. We also used additional unpublished studies and internal communication from the University of Geneva Hospitals and partner institutions. RESULTS: This paper analyzes the acceptable methods for respirator decontamination and reuse, and scores them according to a number of variables that we have defined as being crucial (including cost, risk, complexity, time, etc.) to help healthcare facilities decide which method of decontamination is right for them. CONCLUSION: We provide a resource for healthcare institutions looking at making informed decisions about respirator decontamination. This informed decision making will help to improve infection prevention and control measures, and protect healthcare workers during this crucial time. The overall take home message is that institutions should not reuse respirators unless they have to. In the case of an emergency situation, there are some safe ways to decontaminate them.


Asunto(s)
COVID-19/prevención & control , Descontaminación/métodos , Equipo Reutilizado , Respiradores N95/normas , SARS-CoV-2 , Óxido de Etileno/farmacología , Personal de Salud , Humanos , Peróxido de Hidrógeno/farmacología , Respiradores N95/virología , SARS-CoV-2/efectos de los fármacos , SARS-CoV-2/efectos de la radiación , Vapor , Rayos Ultravioleta
6.
Int J Infect Dis ; 104: 41-44, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33383222

RESUMEN

OBJECTIVES: Due to the surge in demand for N95 masks during the Covid-19 pandemic, and considering the situation in countries grappling with acute shortages of N95 masks, this study investigated the possibilities of decontamination and reuse of masks. METHODS: Three N95 masks of different makes (A, B and C) were subjected to six decontamination methods: ultraviolet (UV) irradiation, isopropyl alcohol (IPA) dip, plasma sterilization (Sterrad®), ethylene oxide (ETO, 3M®), dry heat sterilization, and moist heat sterilization (autoclaving). The integrity of the N95 masks was assessed by measuring their particle filtering efficiency at particle sizes ranging 0.3-0.5 microns. RESULTS: All the masks decontaminated with ETO and plasma sterilization retained over 95% particle filtering efficiency. Masks decontaminated using IPA dip and autoclaving showed a drop, and UV irradiation showed variations in particle size efficiency degradation after decontamination. CONCLUSIONS: Plasma sterilization is recommended for decontamination of N95 masks in low-resource settings. ETO is not recommended due to hazards associated with handling of ethylene oxide, although the filtering efficiency was retained. Since the UV irradiation method showed variations in results, evaluation of UV decontamination for N95 masks needs to be performed on a case-by-case basis.


Asunto(s)
COVID-19/prevención & control , Descontaminación/métodos , Respiradores N95 , SARS-CoV-2 , Equipo Reutilizado , Óxido de Etileno/farmacología , Recursos en Salud , Humanos , India/epidemiología , Rayos Ultravioleta
7.
Food Microbiol ; 94: 103656, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33279081

RESUMEN

The objectives of this study were to investigate the effects of processing parameters (relative humidity (RH), temperature, and exposure time) on the ethylene oxide (EtO) microbial inactivation of Salmonella spp. and to evaluate Enterococcus faecium NRRL B2354 as a suitable surrogate for Salmonella inactivation on cumin seeds. Five grams of cumin seeds inoculated with either Salmonella or E. faecium were treated with EtO at different temperatures (46, 53, and 60 °C) and RH (30, 40, and 50%) levels for different exposure time to investigate the effects of process parameters on the microbial inactivation. The Weibull model fit the survival data of both bacteria with a shape parameter p < 1, which showed a tailing effect with concave shape indicating that the sensitive cells were inactivated first, and the sturdy ones survived at low RH treatment conditions. In general, the log reductions of both bacteria on cumin seeds increased with the increasing RH and temperature for EtO treatment. RH is a critical factor for successful EtO inactivation treatment. RH must be higher than 40% to implement a successful and efficient EtO decontamination of cumin seeds. E. faecium consistently showed lower log reductions than those of Salmonella under all EtO treatment conditions investigated in this study, demonstrating that E. faecium is a suitable surrogate for Salmonella. Twenty minutes of EtO treatment at 50% RH achieved ~5 log reductions of both bacteria at all three temperatures. A response surface model was developed to predict the log reductions of both bacteria under different treatment conditions and the contour plots representing log reductions were created. Inactivation is positively correlated to temperature and RH. Therefore, a higher temperature is required to achieve the desired log reduction at lower RH and vice versa. The developed response surface model is a valuable tool for the spice industry in identifying the possible combinations of EtO process parameters (temperature, RH, and exposure time) required to achieve a desired microbial reduction of Salmonella for ensuring microbial food safety of spices.


Asunto(s)
Cuminum/microbiología , Enterococcus faecium/efectos de los fármacos , Óxido de Etileno/química , Óxido de Etileno/farmacología , Conservación de Alimentos/métodos , Salmonella enterica/efectos de los fármacos , Recuento de Colonia Microbiana , Enterococcus faecium/crecimiento & desarrollo , Conservación de Alimentos/instrumentación , Conservantes de Alimentos/química , Conservantes de Alimentos/farmacología , Inocuidad de los Alimentos , Gases/farmacología , Viabilidad Microbiana/efectos de los fármacos , Salmonella enterica/crecimiento & desarrollo , Semillas/microbiología , Especias/microbiología , Temperatura
8.
PLoS One ; 15(12): e0243965, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33326504

RESUMEN

The response to the COVID-19 epidemic is generating severe shortages of personal protective equipment around the world. In particular, the supply of N95 respirator masks has become severely depleted, with supplies having to be rationed and health care workers having to use masks for prolonged periods in many countries. We sought to test the ability of 7 different decontamination methods: autoclave treatment, ethylene oxide gassing (ETO), low temperature hydrogen peroxide gas plasma (LT-HPGP) treatment, vaporous hydrogen peroxide (VHP) exposure, peracetic acid dry fogging (PAF), ultraviolet C irradiation (UVCI) and moist heat (MH) treatment to decontaminate a variety of different N95 masks following experimental contamination with SARS-CoV-2 or vesicular stomatitis virus as a surrogate. In addition, we sought to determine whether masks would tolerate repeated cycles of decontamination while maintaining structural and functional integrity. All methods except for UVCI were effective in total elimination of viable virus from treated masks. We found that all respirator masks tolerated at least one cycle of all treatment modalities without structural or functional deterioration as assessed by fit testing; filtration efficiency testing results were mostly similar except that a single cycle of LT-HPGP was associated with failures in 3 of 6 masks assessed. VHP, PAF, UVCI, and MH were associated with preserved mask integrity to a minimum of 10 cycles by both fit and filtration testing. A similar result was shown with ethylene oxide gassing to the maximum 3 cycles tested. Pleated, layered non-woven fabric N95 masks retained integrity in fit testing for at least 10 cycles of autoclaving but the molded N95 masks failed after 1 cycle; filtration testing however was intact to 5 cycles for all masks. The successful application of autoclaving for layered, pleated masks may be of particular use to institutions globally due to the virtually universal accessibility of autoclaves in health care settings. Given the ability to modify widely available heating cabinets on hospital wards in well-resourced settings, the application of moist heat may allow local processing of N95 masks.


Asunto(s)
Descontaminación/métodos , Equipo Reutilizado , Respiradores N95/virología , COVID-19/patología , COVID-19/virología , Óxido de Etileno/farmacología , Humanos , Peróxido de Hidrógeno/farmacología , Ácido Peracético/farmacología , Gases em Plasma/farmacología , SARS-CoV-2/efectos de los fármacos , SARS-CoV-2/aislamiento & purificación , SARS-CoV-2/efectos de la radiación , Rayos Ultravioleta , Vesiculovirus/efectos de los fármacos , Vesiculovirus/efectos de la radiación
9.
JAMA Intern Med ; 180(12): 1607-1612, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-32780113

RESUMEN

Importance: Procuring respiratory protection for clinicians and other health care workers has become a major challenge of the coronavirus disease 2019 (COVID-19) pandemic and has resulted in nonstandard practices such as the use of expired respirators and various decontamination processes to prolong the useful life of respirators in health care settings. In addition, imported, non-National Institute for Occupational Safety and Health (NIOSH)-approved respirators have been donated or acquired by hospitals as a potential replacement for limited NIOSH-approved N95 respirators. Objective: To assess fitted filtration efficiencies (FFEs) for face mask alternatives used during the COVID-19 pandemic. Design, Setting, and Participants: For this quality-improvement study conducted between April and June 2020, we used the Occupational Safety and Health Administration's Quantitative Fit Testing Protocol for Filtering Facepiece Respirators in a laboratory atmosphere supplemented with sodium chloride particles to assess the FFEs of a variety of respirators worn by a male volunteer and female volunteer. Main Outcomes and Measures: The FFEs of respirators commonly worn by clinicians and other health care workers and available respirator alternatives during the COVID-19 pandemic. Results: Of the 29 different fitted face mask alternatives tested on 1 man and 1 woman, expired N95 respirators with intact elastic straps and respirators subjected to ethylene oxide and hydrogen peroxide sterilization had unchanged FFE (>95%). The performance of N95 respirators in the wrong size had slightly decreased performance (90%-95% FFE). All of the respirators not listed as approved in this evaluation (n = 6) failed to achieve 95% FFE. Neither of the 2 imported respirators authorized for use by the Centers for Disease Control and Prevention that were not NIOSH-approved tested in this study achieved 95% FFE, and the more effective of the 2 functioned at approximately 80% FFE. Surgical and procedural face masks had filtering performance that was lower relative to that of N95 respirators (98.5% overall FFE), with procedural face masks secured with elastic ear loops showing the lowest efficiency (38.1% overall FFE). Conclusions and Relevance: This quality-improvement study evaluating 29 face mask alternatives for use by clinicians interacting with patients during the COVID-19 pandemic found that expired N95 respirators and sterilized, used N95 respirators can be used when new N95 respirators are not available. Other alternatives may provide less effective filtration.


Asunto(s)
COVID-19 , Equipo Reutilizado/normas , Filtración/normas , Control de Infecciones/instrumentación , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Máscaras , Respiradores N95 , Esterilización , COVID-19/epidemiología , COVID-19/prevención & control , COVID-19/transmisión , Desinfectantes , Contaminación de Equipos/prevención & control , Análisis de Falla de Equipo/métodos , Óxido de Etileno/farmacología , Personal de Salud , Humanos , Peróxido de Hidrógeno/farmacología , Máscaras/clasificación , Máscaras/normas , Máscaras/provisión & distribución , Ensayo de Materiales/métodos , Respiradores N95/normas , Respiradores N95/provisión & distribución , Mejoramiento de la Calidad , SARS-CoV-2 , Esterilización/métodos , Esterilización/normas
10.
Tissue Eng Part A ; 26(19-20): 1077-1090, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32264787

RESUMEN

This study investigated the effects of terminal sterilization of polyvinyl alcohol (PVA) biomaterials using clinically translatable techniques, specifically ethylene oxide (EtO) and gamma (γ) irradiation. While a few studies have reported the possibility of sterilizing PVA with γ-radiation, the use of EtO sterilization of PVA requires additional study. PVA solutions were chemically crosslinked with trisodium trimetaphosphate and sodium hydroxide. The three experimental groups included untreated control, EtO, and γ-irradiation, which were tested for the degree of swelling and water content, and mechanical properties such as radial compliance, longitudinal tensile, minimum bend radius, burst pressure, and suture retention strength. In addition, samples were characterized with scanning electron microscopy, differential scanning calorimetry, X-ray photoelectron spectroscopy, and water contact angle measurements. Cell attachment was assessed using the endothelial cell line EA.hy926, and the sterilized PVA cytotoxicity was studied with a live/dead stain. Platelet and fibrin accumulation was measured using an ex vivo shunt baboon model. Finally, the immune responses of PVA implants were analyzed after a 21-day subcutaneous implantation in rats and a 30-day implantation in baboon. EtO sterilization reduced the PVA graft wall thickness, its degree of swelling, and water content compared with both γ-irradiated and untreated PVA. Moreover, EtO sterilization significantly reduced the radial compliance and increased Young's modulus. EtO did not change PVA hydrophilicity, while γ-irradiation increased the water contact angle of the PVA. Consequently, endothelial cell attachment on the EtO-sterilized PVA showed similar results to the untreated PVA, while cell attachment significantly improved on the γ-irradiated PVA. When exposing the PVA grafts to circulating whole blood, fibrin accumulation of EtO-sterilized PVA was found to be significantly lower than γ-irradiated PVA. The immune responses of γ-irradiated PVA, EtO-treated PVA, and untreated PVA were compared. Implanted EtO-treated PVA showed the least MAC387 reaction. The terminal sterilization methods in this study changed PVA hydrogel properties; nevertheless, based on the characterizations performed, both sterilization methods were suitable for sterilizing PVA. We concluded that EtO can be used as an alternative method to sterilize PVA hydrogel material. Impact statement Polyvinyl alcohol (PVA) hydrogels have been used for a variety of tissue replacements, including neural, cardiac, meniscal, cartilage, muscle, pancreatic, and ocular applications. In addition, PVA can be made into a tubular shape and used as a small-diameter vascular graft. Ethylene oxide (EtO) is one of the Food and Drug Administration-approved methods for sterilization, but its effect on PVA has not been studied extensively. The outcome of this study provides the effects of EtO and γ-irradiation of PVA grafts on both the material properties and the in vivo responses, particularly for vascular applications. Knowledge of these effects may ultimately improve the success rate of PVA vascular grafts.


Asunto(s)
Óxido de Etileno , Hidrogeles , Alcohol Polivinílico , Esterilización , Animales , Óxido de Etileno/farmacología , Rayos gamma , Papio , Ratas
11.
Infect Control Hosp Epidemiol ; 41(4): 391-395, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32098638

RESUMEN

OBJECTIVE: To compare the microbicidal activity of low-temperature sterilization technologies (vaporized hydrogen peroxide [VHP], ethylene oxide [ETO], and hydrogen peroxide gas plasma [HPGP]) to steam sterilization in the presence of salt and serum to simulate inadequate precleaning. METHODS: Test carriers were inoculated with Pseudomonas aeruginosa, Escherichia coli, Staphylococcus aureus, vancomycin-resistant Enterococcus, Mycobacterium terrae, Bacillus atrophaeus spores, Geobacillus stearothermophilus spores, or Clostridiodes difficile spores in the presence of salt and serum and then subjected to 4 sterilization technologies: steam, ETO, VHP and HPGP. RESULTS: Steam, ETO, and HPGP sterilization techniques were capable of inactivating the test organisms on stainless steel carriers with a failure rate of 0% (0 of 220), 1.9% (6 of 310), and 1.9% (5 of 270), respectively. The failure rate for VHP was 76.3% (206 of 270). CONCLUSION: Steam sterilization is the most effective and had the largest margin of safety, followed by ETO and HPGP, but VHP showed much less efficacy.


Asunto(s)
Esporas Bacterianas/efectos de los fármacos , Esterilización/métodos , Enterococcus , Escherichia coli , Óxido de Etileno/farmacología , Humanos , Peróxido de Hidrógeno/farmacología , Micobacterias no Tuberculosas , Pseudomonas aeruginosa , Staphylococcus aureus , Vapor , Temperatura , Resistencia a la Vancomicina
12.
J Appl Microbiol ; 127(5): 1403-1420, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31410952

RESUMEN

Medical devices are an important and growing aspect of healthcare provision and are increasing in complexity to meet established and emerging patient needs. Terminal sterilization plays a vital role in the provision of safe medical devices. While terminal sterilization technologies for medical devices include multiple radiation options, ethylene oxide remains the predominant nonthermal gaseous option, sterilizing c. 50% of all manufactured devices. Vaporized hydrogen peroxide (abbreviated VH2O2 by the International Organization for Standardization) is currently deployed for clinical sterilization applications, where its performance characteristics appear aligned to requirements, constituting a viable alternative low-temperature process for terminal processing of medical devices. However, VH2O2 has operational limitations that create technical challenges for industrial-scale adoption. This timely review provides a succinct overview of VH2O2 in gaseous sterilization and addresses its applicability for terminal sterilization of medical devices. It also describes underappreciated factors such as the occurrence of nonlinear microbial inactivation kinetic plots that may dictate a need to develop a new standard approach to validate VH2O2 for terminal sterilization of medical devices.


Asunto(s)
Contaminación de Equipos/prevención & control , Peróxido de Hidrógeno/química , Esterilización/métodos , Bacterias/efectos de los fármacos , Equipos y Suministros de Hospitales/microbiología , Equipos y Suministros de Hospitales/estadística & datos numéricos , Óxido de Etileno/química , Óxido de Etileno/farmacología , Gases/química , Peróxido de Hidrógeno/farmacología , Esterilización/instrumentación
13.
Bioorg Chem ; 90: 103058, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31212181

RESUMEN

Cinnamic anhydrides have been shown to be more than reactive reagents, but they also act as inhibitors of the enzyme acetylcholinesterease (AChE). Thus, out of a set of 33 synthesised derivatives, several of them were mixed type inhibitors for AChE (from electric eel). Thus, (E)-3-(2,4-dimethoxyphenyl)acrylic anhydride (2c) showed Ki = 8.30 ±â€¯0.94 µM and Ki' = 9.54 ±â€¯0.38 µM, and for (E)-3-(3-chlorophenyl)acrylic anhydride (2u) Ki = 8.23 ±â€¯0.93 µM and Ki' = 13.07 ±â€¯0.46 µM were measured. While being not cytotoxic to many human cell lines, these compounds showed an unprecedented and noteworthy inhibitory effect for AChE but not for butyrylcholinesterase (BChE).


Asunto(s)
Acetilcolinesterasa/química , Butirilcolinesterasa/química , Inhibidores de la Colinesterasa/farmacología , Cinamatos/química , Óxido de Etileno/farmacología , Proliferación Celular , Inhibidores de la Colinesterasa/química , Óxido de Etileno/análogos & derivados , Óxido de Etileno/química , Humanos , Simulación del Acoplamiento Molecular , Estructura Molecular , Neoplasias/tratamiento farmacológico , Neoplasias/patología , Conformación Proteica , Relación Estructura-Actividad , Células Tumorales Cultivadas
14.
Mater Sci Eng C Mater Biol Appl ; 92: 132-142, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30184736

RESUMEN

The study describes the detailed examination of the effect of ethylene oxide sterilization on electrospun scaffolds constructed from biodegradable polyesters. Different fibrous layers fabricated from polycaprolactone (PCL) and a copolymer consisting of polylactide and polycaprolactone (PLCL) were investigated for the determination of their mechanical properties, degradation rates and interaction with fibroblasts. It was discovered that the sterilization procedure influenced the mechanical properties of the electrospun PLCL copolymer scaffold to the greatest extent. No effect of ethylene oxide sterilization on degradation behavior was observed. However, a delayed fibroblast proliferation rate was noticed with concern to the ethylene oxide sterilized samples compared to the ethanol sterilization of the materials.


Asunto(s)
Materiales Biocompatibles/química , Óxido de Etileno/química , Poliésteres/química , Animales , Materiales Biocompatibles/metabolismo , Materiales Biocompatibles/farmacología , Prótesis Vascular , Línea Celular , Supervivencia Celular/efectos de los fármacos , Módulo de Elasticidad , Óxido de Etileno/farmacología , Ratones , Microscopía Electrónica de Rastreo , Nanofibras/química , Poliésteres/metabolismo , Esterilización , Resistencia a la Tracción
15.
J Photochem Photobiol B ; 187: 54-60, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30099269

RESUMEN

Over the past decade, the implementation of the novel nanomaterials in the field of nanotechnology for the biomedical applications is essential for the comfort factors such as non-toxicity and biocompatibility in the human biological systems. In this context, a novel synthesis was worked out through bacterial species (citrobacter braakii) in the biofabrication of bioactive gold nanoparticles (Au NPs) for the wound healing management. The biosynthesized Au NPs were further modified and improved its compatibility with polyethylene glycol (PEG) and polycaprolactone (PCL) for formed as Au-PEG/PCL nanocomposites to extent the activity in wound healing application. The combination of bioactive nanoparticles with biocompatible polymeric substances has been upsurges the activity of nanoparticles due to the strong interaction of polymers. The biofabricated Au NPs and its nanocomposites were characterized using UV-Vis, FT-IR, XRD, DLS and TEM studies. Further, the prepared materials were tested in a wound healing model of rat with the wound of 22 mm size. The found results are demonstrated that the improved materials are highly active in growth of keratinocytes proliferation and simultaneously reduce scar formation. After 15 days observations, the wound were almost completely healed by the developed Au- PEG/PCL nanocomposites material which was confirmed by Masson's Trichrome staining histological images and antibacterial efficacy was displayed by the CLSM images. Notably, polymeric Au-PEG/PCL nanocomposites showed no inflammation on the wounded portion and internal implantation on rats thus evidencing it as a safe and biologically very active wound healing agent.


Asunto(s)
Óxido de Etileno/química , Lactonas/química , Nanopartículas del Metal/química , Nanocompuestos/química , Cicatrización de Heridas , Animales , Citrobacter/efectos de los fármacos , Óxido de Etileno/farmacología , Oro/química , Lactonas/farmacología , Nanocompuestos/uso terapéutico , Nanocompuestos/toxicidad , Tamaño de la Partícula , Ratas , Enfermedades del Recto/patología , Enfermedades del Recto/cirugía , Espectroscopía Infrarroja por Transformada de Fourier , Cicatrización de Heridas/efectos de los fármacos
16.
J Biomed Mater Res B Appl Biomater ; 106(2): 680-688, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28306194

RESUMEN

Half of the female population over age 50 years will experience pelvic organ prolapse. We suggest a new approach based on tissue engineering principles to functionally reconstruct the anatomical structures of the pelvic floor. The aim of this study is to investigate the mechanical performance and effect on collagen and elastin production of a degradable mesh releasing basic fibroblast growth factor (bFGF). Implantation of biodegradable mesh with or without bFGF in their core has been conducted in 40 rats in an abdominal wall defect model. Samples were explanted after 4, 8, and 24 weeks, and tested for mechanical properties and the composition of connective tissue. The study showed an increase in mRNA expression for collagen-I (p = 0.0060) and collagen-III (p = 0.0086) in the 4 weeks group with bFGF. The difference was equalized at 8 and 24 weeks. No difference was found at any time for protein amount for collagen-I, collagen-III, and fibronectin. The amount of collagen decreased from 4 to 24 weeks but the fraction of collagen increased. The maximal load of the newly formed tissue showed no effect of bFGF at any time. Exclusively, histology showed a limited ingrowth of collagen fibers after 4 weeks with bFGF but signs of elastin fibers were seen at 24 weeks. The investigation showed that a biodegradable mesh promotes tissue formation with a promising strength. The mesh with bFGF did not represent any advantage on either long or short term in comparison to the mesh without bFGF. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 680-688, 2018.


Asunto(s)
Pared Abdominal/patología , Implantes Absorbibles , Colágeno Tipo III/metabolismo , Colágeno Tipo I/metabolismo , Elastina/metabolismo , Animales , Colágeno Tipo I/genética , Colágeno Tipo III/genética , Modelos Animales de Enfermedad , Elastina/genética , Óxido de Etileno/química , Óxido de Etileno/farmacología , Femenino , Factor 2 de Crecimiento de Fibroblastos/química , Factor 2 de Crecimiento de Fibroblastos/farmacología , Fibronectinas/genética , Fibronectinas/metabolismo , Lactonas/química , Lactonas/farmacología , Diafragma Pélvico/patología , Ratas , Ratas Wistar , Mallas Quirúrgicas , Ingeniería de Tejidos
17.
Mar Drugs ; 16(1)2017 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-29286293

RESUMEN

Red algae of Laurencia continue to provide wide structural diversity and complexity of halogenated C15 acetogenin medium-ring ethers. Here, we described the isolation of three new C15 acetogenins (3-5), and one truncated derivative (6) from Laurencia viridis collected on the Canary Islands. These compounds are interesting variations on the pinnatifidenyne structure that included the first examples of ethynyl oxirane derivatives (3-4). The structures were elucidated by extensive study of NMR (Nuclear Magnetic Resonance) data, J-based configuration analysis and DFT (Density Functional Theory) calculations. Their antiproliferative activity against six human solid tumor cell lines was evaluated.


Asunto(s)
Acetogeninas/química , Éteres Cíclicos/química , Óxido de Etileno/química , Laurencia/química , Acetogeninas/aislamiento & purificación , Acetogeninas/farmacología , Antineoplásicos/farmacología , Línea Celular Tumoral , Ensayos de Selección de Medicamentos Antitumorales , Óxido de Etileno/aislamiento & purificación , Óxido de Etileno/farmacología , Humanos , Espectroscopía de Resonancia Magnética , Modelos Moleculares , Conformación Molecular , Estructura Molecular
18.
J Food Sci ; 82(5): 1208-1215, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28407236

RESUMEN

Selected processing methods, demonstrated to be effective at reducing Salmonella, were assessed to determine if spice and herb quality was affected. Black peppercorn, cumin seed, oregano, and onion powder were irradiated to a target dose of 8 kGy. Two additional processes were examined for whole black peppercorns and cumin seeds: ethylene oxide (EtO) fumigation and vacuum assisted-steam (82.22 °C, 7.5 psia). Treated and untreated spices/herbs were compared (visual, odor) using sensory similarity testing protocols (α = 0.20; ß = 0.05; proportion of discriminators: 20%) to determine if processing altered sensory quality. Analytical assessment of quality (color, water activity, and volatile chemistry) was completed. Irradiation did not alter visual or odor sensory quality of black peppercorn, cumin seed, or oregano but created differences in onion powder, which was lighter (higher L* ) and more red (higher a* ) in color, and resulted in nearly complete loss of measured volatile compounds. EtO processing did not create detectable odor or appearance differences in black peppercorn; however visual and odor sensory quality differences, supported by changes in color (higher b* ; lower L* ) and increased concentrations of most volatiles, were detected for cumin seeds. Steam processing of black peppercorn resulted in perceptible odor differences, supported by increased concentration of monoterpene volatiles and loss of all sesquiterpenes; only visual differences were noted for cumin seed. An important step in process validation is the verification that no effect is detectable from a sensory perspective.


Asunto(s)
Cuminum/química , Óxido de Etileno/farmacología , Piper nigrum/química , Especias/análisis , Vapor , Monoterpenos/análisis , Semillas/química , Sesquiterpenos/análisis
19.
Infect Control Hosp Epidemiol ; 38(2): 136-142, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27866488

RESUMEN

BACKGROUND Endoscope-associated infections are reported despite following proper reprocessing methods. Microbiological testing can confirm the adequacy of endoscope reprocessing. Multiple controversies related to the method and interpretation of microbiological testing cultures have arisen that make their routine performance a complex target. OBJECTIVE We conducted a pilot study using disposable bronchoscopes (DBs) to simulate different reprocessing times and soaking times and to compare high-level disinfection versus ethylene oxide sterilization. We also reviewed the time to reprocessing and duration of the procedures. METHODS Bronchoscopes were chosen because an alternative disposable scope is commercially available and because bronchoscopes are more prone to delays in processing. Disposable bronchoscopes were contaminated using a liquid bacterial suspension and were then incubated for 1-4 hours. Standard processing and high-level disinfection were performed on 36 endoscopes. Ethylene oxide sterilization was performed on 21 endoscopes. Endoscope cultures were performed using the standard "brush, flush, brush" technique. RESULTS After brushing was performed, a final water-flush culture procedure was the most effective method of detecting bacterial persistence on the disposable scopes. Klebsiella pneumoniae was the most commonly recovered organism after reprocessing. Ethylene oxide sterilization did not result in total elimination of viable bacteria. CONCLUSION Routine endoscopy cultures may be required to assess the adequacy of endoscopic processing. Infect Control Hosp Epidemiol 2017;38:136-142.


Asunto(s)
Bacterias/aislamiento & purificación , Broncoscopios/microbiología , Desinfección/métodos , Equipos Desechables/microbiología , Contaminación de Equipos , Bacterias/clasificación , Óxido de Etileno/farmacología , Humanos , Proyectos Piloto , Factores de Tiempo
20.
J Coll Physicians Surg Pak ; 26(6): 486-9, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27353985

RESUMEN

OBJECTIVE: To determine the residing microbial flora of ethylene oxide (EtO) sterilized medical devices and optimization of safe dose of gamma radiation (Cobalt 60 source) for the complete elimination of microbial load. STUDY DESIGN: Experimental study. PLACE AND DURATION OF STUDY: Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan from September 2014 to June 2015. METHODOLOGY: Thirty-six samples of EtO sterilized medical devices of same batch of three different companies were collected for this study. Isolation and enumeration of microbes were done by using different selective and differential media. Gram staining and biochemically characterization by API 20 (Bio Merieux, France) kit was done for identification of the microorganisms. The medical devices having high microbial load were sent to Pakistan Radiation Services (PARAS) for gamma irradiations at 3 different selected doses (20 KGy, 25 KGy, and 30 KGy). RESULTS: Different types of Gram positive bacteria (Staphylococcus epidermidis, Staphylococcus aureus andBacillus subtilis) were isolated from the EtO sterilized samples. Gram negative bacteria and fungi were not detected on these medical devices. Gamma irradiations results showed that 30 KGy was optimized dose for complete elimination of microbial flora on endotracheal, Nelaton, and tracheostomy tubes. CONCLUSION: Gamma radiations (Co 60 source) effectively decontaminate the microbial flora on the equipment previously sterilized by the ethylene oxide gas; and 30 KGy is the optimized dose for all these medical devices.


Asunto(s)
Desinfectantes/farmacología , Desinfección/métodos , Equipos y Suministros/microbiología , Óxido de Etileno/farmacología , Rayos gamma , Bacterias Grampositivas/efectos de los fármacos , Bacterias Grampositivas/efectos de la radiación , Esterilización/métodos , Recuento de Colonia Microbiana , Desinfección/instrumentación , Contaminación de Equipos , Seguridad de Equipos , Humanos , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...