Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.502
Filtrar
1.
PLoS One ; 19(5): e0290912, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739600

RESUMEN

This cross-sectional study aimed to identify and validate cut-points for measuring physical activity using Axivity AX6 accelerometers positioned at the shank in older adults. Free-living physical activity was assessed in 35 adults aged 55 and older, where each participant wore a shank-mounted Axivity and a waist-mounted ActiGraph simultaneously for 72 hours. Optimized cut-points for each participant's Axivity data were determined using an optimization algorithm to align with ActiGraph results. To assess the validity between the physical activity assessments from the optimized Axivity cut-points, a leave-one-out cross-validation was conducted. Bland-Altman plots with 95% limits of agreement, intraclass correlation coefficients (ICC), and mean differences were used for comparing the systems. The results indicated good agreement between the two accelerometers when classifying sedentary behaviour (ICC = 0.85) and light physical activity (ICC = 0.80), and moderate agreement when classifying moderate physical activity (ICC = 0.67) and vigorous physical activity (ICC = 0.70). Upon removal of a significant outlier, the agreement was slightly improved for sedentary behaviour (ICC = 0.86) and light physical activity (ICC = 0.82), but substantially improved for moderate physical activity (ICC = 0.81) and vigorous physical activity (ICC = 0.96). Overall, the study successfully demonstrated the capability of the resultant cut-point model to accurately classify physical activity using Axivity AX6 sensors placed at the shank.


Asunto(s)
Acelerometría , Ejercicio Físico , Humanos , Anciano , Masculino , Femenino , Acelerometría/instrumentación , Acelerometría/métodos , Ejercicio Físico/fisiología , Persona de Mediana Edad , Estudios Transversales , Conducta Sedentaria
2.
PLoS One ; 19(5): e0299943, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38701085

RESUMEN

Spending time outdoors is associated with increased time spent in physical activity, lower chronic disease risk, and wellbeing. Many studies rely on self-reported measures, which are prone to recall bias. Other methods rely on features and functions only available in some GPS devices. Thus, a reliable and versatile method to objectively quantify time spent outdoors is needed. This study sought to develop a versatile method to classify indoor and outdoor (I/O) GPS data that can be widely applied using most types of GPS and accelerometer devices. To develop and test the method, five university students wore an accelerometer (ActiGraph wGT3X-BT) and a GPS device (Canmore GT-730FL-S) on an elastic belt at the right hip for two hours in June 2022 and logged their activity mode, setting, and start time via activity diaries. GPS trackers were set to collect data every 5 seconds. A rule-based point cluster-based method was developed to identify indoor, outdoor, and in-vehicle time. Point clusters were detected using an application called GPSAS_Destinations and classification were done in R using accelerometer lux, building footprint, and park location data. Classification results were compared with the submitted activity diaries for validation. A total of 7,006 points for all participants were used for I/O classification analyses. The overall I/O GPS classification accuracy rate was 89.58% (Kappa = 0.78), indicating good classification accuracy. This method provides reliable I/O clarification results and can be widely applied using most types of GPS and accelerometer devices.


Asunto(s)
Acelerometría , Ejercicio Físico , Sistemas de Información Geográfica , Humanos , Sistemas de Información Geográfica/instrumentación , Acelerometría/instrumentación , Acelerometría/métodos , Masculino , Femenino , Ejercicio Físico/fisiología , Adulto Joven , Adulto , Factores de Tiempo
3.
Aging Clin Exp Res ; 36(1): 108, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38717552

RESUMEN

INTRODUCTION: Wrist-worn activity monitors have seen widespread adoption in recent times, particularly in young and sport-oriented cohorts, while their usage among older adults has remained relatively low. The main limitations are in regards to the lack of medical insights that current mainstream activity trackers can provide to older subjects. One of the most important research areas under investigation currently is the possibility of extrapolating clinical information from these wearable devices. METHODS: The research question of this study is understanding whether accelerometry data collected for 7-days in free-living environments using a consumer-based wristband device, in conjunction with data-driven machine learning algorithms, is able to predict hand grip strength and possible conditions categorized by hand grip strength in a general population consisting of middle-aged and older adults. RESULTS: The results of the regression analysis reveal that the performance of the developed models is notably superior to a simple mean-predicting dummy regressor. While the improvement in absolute terms may appear modest, the mean absolute error (6.32 kg for males and 4.53 kg for females) falls within the range considered sufficiently accurate for grip strength estimation. The classification models, instead, excel in categorizing individuals as frail/pre-frail, or healthy, depending on the T-score levels applied for frailty/pre-frailty definition. While cut-off values for frailty vary, the results suggest that the models can moderately detect characteristics associated with frailty (AUC-ROC: 0.70 for males, and 0.76 for females) and viably detect characteristics associated with frailty/pre-frailty (AUC-ROC: 0.86 for males, and 0.87 for females). CONCLUSIONS: The results of this study can enable the adoption of wearable devices as an efficient tool for clinical assessment in older adults with multimorbidities, improving and advancing integrated care, diagnosis and early screening of a number of widespread diseases.


Asunto(s)
Acelerometría , Fuerza de la Mano , Muñeca , Humanos , Fuerza de la Mano/fisiología , Masculino , Femenino , Anciano , Acelerometría/instrumentación , Acelerometría/métodos , Persona de Mediana Edad , Muñeca/fisiología , Dispositivos Electrónicos Vestibles , Anciano de 80 o más Años , Aprendizaje Automático
4.
J Neuroeng Rehabil ; 21(1): 82, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769565

RESUMEN

BACKGROUND: Assessments of arm motor function are usually based on clinical examinations or self-reported rating scales. Wrist-worn accelerometers can be a good complement to measure movement patterns after stroke. Currently there is limited knowledge of how accelerometry correlate to clinically used scales. The purpose of this study was therefore to evaluate the relationship between intermittent measurements of wrist-worn accelerometers and the patient's progression of arm motor function assessed by routine clinical outcome measures during a rehabilitation period. METHODS: Patients enrolled in in-hospital rehabilitation following a stroke were invited. Included patients were asked to wear wrist accelerometers for 24 h at the start (T1) and end (T2) of their rehabilitation period. On both occasions arm motor function was assessed by the modified Motor Assessment Scale (M_MAS) and the Motor Activity Log (MAL). The recorded accelerometry was compared to M_MAS and MAL. RESULTS: 20 patients were included, of which 18 completed all measurements and were therefore included in the final analysis. The resulting Spearman's rank correlation coefficient showed a strong positive correlation between measured wrist acceleration in the affected arm and M-MAS and MAL values at T1, 0.94 (p < 0.05) for M_MAS and 0.74 (p < 0.05) for the MAL values, and a slightly weaker positive correlation at T2, 0.57 (p < 0.05) for M_MAS and 0.46 - 0.45 (p = 0.06) for the MAL values. However, no correlation was seen for the difference between the two sessions. CONCLUSIONS: The results confirm that the wrist acceleration can differentiate between the affected and non-affected arm, and that there is a positive correlation between accelerometry and clinical measures. Many of the patients did not change their M-MAS or MAL scores during the rehabilitation period, which may explain why no correlation was seen for the difference between measurements during the rehabilitation period. Further studies should include continuous accelerometry throughout the rehabilitation period to reduce the impact of day-to-day variability.


Asunto(s)
Acelerometría , Brazo , Rehabilitación de Accidente Cerebrovascular , Humanos , Acelerometría/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Anciano , Rehabilitación de Accidente Cerebrovascular/métodos , Rehabilitación de Accidente Cerebrovascular/instrumentación , Brazo/fisiopatología , Brazo/fisiología , Muñeca/fisiología , Dispositivos Electrónicos Vestibles , Actividad Motora/fisiología , Adulto , Accidente Cerebrovascular/fisiopatología , Accidente Cerebrovascular/diagnóstico , Anciano de 80 o más Años
5.
EBioMedicine ; 103: 105104, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38582030

RESUMEN

BACKGROUND: There is an urgent need for objective and sensitive measures to quantify clinical disease progression and gauge the response to treatment in clinical trials for amyotrophic lateral sclerosis (ALS). Here, we evaluate the ability of an accelerometer-derived outcome to detect differential clinical disease progression and assess its longitudinal associations with overall survival in patients with ALS. METHODS: Patients with ALS wore an accelerometer on the hip for 3-7 days, every 2-3 months during a multi-year observation period. An accelerometer-derived outcome, the Vertical Movement Index (VMI), was calculated, together with predicted disease progression rates, and jointly analysed with overall survival. The clinical utility of VMI was evaluated using comparisons to patient-reported functionality, while the impact of various monitoring schemes on empirical power was explored through simulations. FINDINGS: In total, 97 patients (70.1% male) wore the accelerometer for 1995 days, for a total of 27,701 h. The VMI was highly discriminatory for predicted disease progression rates, revealing faster rates of decline in patients with a worse predicted prognosis compared to those with a better predicted prognosis (p < 0.0001). The VMI was strongly associated with the hazard for death (HR 0.20, 95% CI: 0.09-0.44, p < 0.0001), where a decrease of 0.19-0.41 unit was associated with reduced ambulatory status. Recommendations for future studies using accelerometery are provided. INTERPRETATION: The results serve as motivation to incorporate accelerometer-derived outcomes in clinical trials, which is essential for further validation of these markers to meaningful endpoints. FUNDING: Stichting ALS Nederland (TRICALS-Reactive-II).


Asunto(s)
Esclerosis Amiotrófica Lateral , Progresión de la Enfermedad , Dispositivos Electrónicos Vestibles , Humanos , Esclerosis Amiotrófica Lateral/mortalidad , Esclerosis Amiotrófica Lateral/diagnóstico , Esclerosis Amiotrófica Lateral/fisiopatología , Masculino , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Anciano , Acelerometría/instrumentación , Pronóstico , Tecnología de Sensores Remotos/instrumentación , Tecnología de Sensores Remotos/métodos , Adulto
6.
Int J Behav Nutr Phys Act ; 21(1): 43, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38654342

RESUMEN

BACKGROUND: The development of validated "fit-for-purpose" rapid assessment tools to measure 24-hour movement behaviours in children aged 0-5 years is a research priority. This study evaluated the test-retest reliability and concurrent validity of the open-ended and closed-ended versions of the Movement Behaviour Questionnaire for baby (MBQ-B) and child (MBQ-C). METHODS: 300 parent-child dyads completed the 10-day study protocol (MBQ-B: N = 85; MBQ-C: N = 215). To assess validity, children wore an accelerometer on the non-dominant wrist (ActiGraph GT3X+) for 7 days and parents completed 2 × 24-hour time use diaries (TUDs) recording screen time and sleep on two separate days. For babies (i.e., not yet walking), parents completed 2 × 24-hour TUDs recording tummy time, active play, restrained time, screen time, and sleep on days 2 and 5 of the 7-day monitoring period. To assess test-retest reliability, parents were randomised to complete either the open- or closed-ended versions of the MBQ on day 7 and on day 10. Test-retest intraclass correlation coefficients (ICC's) were calculated using generalized linear mixed models and validity was assessed via Spearman correlations. RESULTS: Test-retest reliability for the MBQ-B was good to excellent with ICC's ranging from 0.80 to 0.94 and 0.71-0.93 for the open- and closed-ended versions, respectively. For both versions, significant positive correlations were observed between 24-hour diary and MBQ-B reported tummy time, active play, restrained time, screen time, and sleep (rho = 0.39-0.87). Test-retest reliability for the MBQ-C was moderate to excellent with ICC's ranging from 0.68 to 0.98 and 0.44-0.97 for the open- and closed-ended versions, respectively. For both the open- and closed-ended versions, significant positive correlations were observed between 24-hour diary and MBQ-C reported screen time and sleep (rho = 0.44-0.86); and between MBQ-C reported and device-measured time in total activity and energetic play (rho = 0.27-0.42). CONCLUSIONS: The MBQ-B and MBQ-C are valid and reliable rapid assessment tools for assessing 24-hour movement behaviours in infants, toddlers, and pre-schoolers. Both the open- and closed-ended versions of the MBQ are suitable for research conducted for policy and practice purposes, including the evaluation of scaled-up early obesity prevention programs.


Asunto(s)
Padres , Sueño , Humanos , Lactante , Femenino , Masculino , Reproducibilidad de los Resultados , Preescolar , Encuestas y Cuestionarios/normas , Sueño/fisiología , Acelerometría/métodos , Acelerometría/instrumentación , Conducta Infantil , Tiempo de Pantalla , Movimiento , Recién Nacido , Conducta Sedentaria , Ejercicio Físico
7.
Sleep Med ; 118: 71-77, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38613859

RESUMEN

BACKGROUND: Multiple Sclerosis (MS) is a chronic inflammatory autoimmune, neurodegenerative disease that affects regular mobility and leads predominantly to physical disability. Poor sleep quality, commonly reported in MS patients, impacts their physical activity (PA). Accelerometers monitor 24-h activity patterns, offering insights into disease progression in daily life. OBJECTIVE: To test if the sleep quality variables of MS patients, as assessed with wrist-worn accelerometers, differ from those of controls and are associated with PA and disease severity variables. METHODS: Seven-day raw accelerometer data collected from 40 MS patients and 24 controls was processed using an open-source GGIR package, from which variables of sleep quality (sleep efficiency, wake after sleep onset (WASO), sleep regularity index (SRI), intradaily variability (IV)) and PA (of different intensities: inactivity, light (LPA), moderate (MPA), vigorous (VPA)) were analyzed. The variables were compared between the two study groups and in MS patients, correlation tested associations among the variables of sleep quality, PA, and disease severity (assessed with the Expanded Disability Status Scale, EDSS). RESULTS: Sleep efficiency was the only variable that differed significantly between MS patients and controls (lower in MS, p = 0.01). Both SRI (positively) and IV (negatively) correlated with the time spent in LPA and MPA. WASO correlated negatively with inactivity. CONCLUSION: This is one of the few studies with a wrist-worn accelerometer that shows a difference in sleep efficiency between MS patients and controls and, in MS, an association of sleep quality variables with PA variables.


Asunto(s)
Acelerometría , Ejercicio Físico , Esclerosis Múltiple , Índice de Severidad de la Enfermedad , Calidad del Sueño , Humanos , Femenino , Masculino , Ejercicio Físico/fisiología , Esclerosis Múltiple/complicaciones , Esclerosis Múltiple/fisiopatología , Acelerometría/instrumentación , Adulto , Persona de Mediana Edad
8.
Sensors (Basel) ; 24(8)2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38676029

RESUMEN

The increasing use of inertial measurement units (IMU) in biomedical sciences brings new possibilities for clinical research. The aim of this paper is to demonstrate the accuracy of the IMU-based wearable Syde® device, which allows day-long and remote continuous gait recording in comparison to a reference motion capture system. Twelve healthy subjects (age: 23.17 ± 2.04, height: 174.17 ± 6.46 cm) participated in a controlled environment data collection and performed a series of gait tasks with both systems attached to each ankle. A total of 2820 strides were analyzed. The results show a median absolute stride length error of 1.86 cm between the IMU-based wearable device reconstruction and the motion capture ground truth, with the 75th percentile at 3.24 cm. The median absolute stride horizontal velocity error was 1.56 cm/s, with the 75th percentile at 2.63 cm/s. With a measurement error to the reference system of less than 3 cm, we conclude that there is a valid physical recovery of stride length and horizontal velocity from data collected with the IMU-based wearable Syde® device.


Asunto(s)
Tobillo , Marcha , Dispositivos Electrónicos Vestibles , Humanos , Marcha/fisiología , Masculino , Tobillo/fisiología , Femenino , Adulto , Adulto Joven , Fenómenos Biomecánicos/fisiología , Acelerometría/instrumentación , Acelerometría/métodos , Análisis de la Marcha/métodos , Análisis de la Marcha/instrumentación
9.
Int J Behav Nutr Phys Act ; 21(1): 48, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671485

RESUMEN

BACKGROUND: Sedentary behavior (SB) is a recognized risk factor for many chronic diseases. ActiGraph and activPAL are two commonly used wearable accelerometers in SB research. The former measures body movement and the latter measures body posture. The goal of the current study is to quantify the pattern and variation of movement (by ActiGraph activity counts) during activPAL-identified sitting events, and examine associations between patterns and health-related outcomes, such as systolic and diastolic blood pressure (SBP and DBP). METHODS: The current study included 314 overweight postmenopausal women, who were instructed to wear an activPAL (at thigh) and ActiGraph (at waist) simultaneously for 24 hours a day for a week under free-living conditions. ActiGraph and activPAL data were processed to obtain minute-level time-series outputs. Multilevel functional principal component analysis (MFPCA) was applied to minute-level ActiGraph activity counts within activPAL-identified sitting bouts to investigate variation in movement while sitting across subjects and days. The multilevel approach accounted for the nesting of days within subjects. RESULTS: At least 90% of the overall variation of activity counts was explained by two subject-level principal components (PC) and six day-level PCs, hence dramatically reducing the dimensions from the original minute-level scale. The first subject-level PC captured patterns of fluctuation in movement during sitting, whereas the second subject-level PC delineated variation in movement during different lengths of sitting bouts: shorter (< 30 minutes), medium (30 -39 minutes) or longer (> 39 minute). The first subject-level PC scores showed positive association with DBP (standardized ß ^ : 2.041, standard error: 0.607, adjusted p = 0.007), which implied that lower activity counts (during sitting) were associated with higher DBP. CONCLUSION: In this work we implemented MFPCA to identify variation in movement patterns during sitting bouts, and showed that these patterns were associated with cardiovascular health. Unlike existing methods, MFPCA does not require pre-specified cut-points to define activity intensity, and thus offers a novel powerful statistical tool to elucidate variation in SB patterns and health. TRIAL REGISTRATION: ClinicalTrials.gov NCT03473145; Registered 22 March 2018; https://clinicaltrials.gov/ct2/show/NCT03473145 ; International Registered Report Identifier (IRRID): DERR1-10.2196/28684.


Asunto(s)
Análisis de Componente Principal , Conducta Sedentaria , Sedestación , Dispositivos Electrónicos Vestibles , Humanos , Femenino , Persona de Mediana Edad , Acelerometría/instrumentación , Acelerometría/métodos , Presión Sanguínea/fisiología , Actigrafía/instrumentación , Actigrafía/métodos , Anciano , Sobrepeso , Posmenopausia/fisiología , Ejercicio Físico/fisiología , Movimiento
10.
J Anim Sci ; 1022024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38581277

RESUMEN

Accelerometers are useful in analyzing lying behavior in farm animals. The effect of the farrowing system on sow lying behavior has been studied around parturition, but not long-term. In a natural environment, sows increase activity 14 d post parturition, which we expected to be also evident in housed sows when they can move freely. The objective of this study was (1) to validate the methodology to automatically measure sow lying bouts and duration with accelerometers and (2) to apply it to crated and free-farrowing sows 24-h pre-parturition until weaning. We used videos with manual behavior coding as the gold standard for validation and calculated the agreement with an intraclass correlation coefficient (ICC), which was 0.30 (95% CI: -0.10 to 0.64) for the number of lying bouts. When transitional sitting bouts were excluded from the video dataset, the ICC for lying bouts increased to 0.86 (95% CI: 0.40 to 0.95). For lying duration, the ICC was 0.93 (95% CI: 0.26 to 0.98). We evaluated the effects of housing, day relative to parturition, and time of day on lying using the accelerometer data and linear mixed models. In crated sows, the number of lying bouts increased toward parturition, peaking at about five bouts per 6 h, and decreased to almost zero bouts after parturition. Then, it increased again (P = 0.001). In free-farrowing sows, the number of lying bouts gradually decreased from a high level towards parturition and was lowest after parturition. It remained constant, as in the crated sows, until day 15, when the number of bouts increased to eight bouts on day 20 (P = 0.001). Sows in both systems were lying almost all of the time between 18:00 and 00:00 hours and on all days (P = 0.001). The crated sows showed a very similar pattern in the other three-quarters of the day with a reduced lying time before parturition, a peak after parturition, reduced lying time from days 5 to 20, and an increase again towards weaning (P = 0.001). Free-farrowing sows had a similar pattern to the crated sows from 00:00 to 06:00 hours, but without the reduction in lying time from days 5 to 20. They showed an increase in lying time toward parturition, which remained constant with a final decrease toward weaning, especially during the day (P = 0.001). This study proves the accuracy of accelerometer-based sow lying behavior classification and shows that free-farrowing systems benefit lactating sows around parturition but also towards weaning in the nest-leaving phase by facilitating activity.


We analyzed lying behavior of sows using sensors, focusing on crated versus free-farrowing sows from pre-parturition to weaning. Lying behavior varies in this time following the needs of the sow and her litter. In a natural environment, sows increase activity 14 d post parturition, which we expected to be also evident in housed sows when they are allowed to move freely. Validation with video data showed excellent agreement for duration and frequency of lying. In crated sows, the number of lying bouts peaked around parturition, decreased after parturition, and then gradually increased. In free-farrowing sows, lying down occurred less often before parturition, but increased by day 20 compared to crated sows. Both housing systems showed prolonged lying periods from 18:00 to 00:00 hours. Crated sows had reduced lying times before parturition and lied longest post-parturition, which decreased until day 5 and then increased toward weaning. Free-farrowing sows had similar nocturnal patterns but persistent lying times that increased prior to parturition and decreased prior to weaning. Overall, the study highlighted the accuracy of accelerometer-based lying behavior classification and showed that free-farrowing systems benefit lactating sows not only around parturition but also toward weaning, facilitating activity during the nest-leaving phase.


Asunto(s)
Acelerometría , Conducta Animal , Vivienda para Animales , Animales , Femenino , Acelerometría/veterinaria , Acelerometría/instrumentación , Porcinos/fisiología , Parto/fisiología , Embarazo , Crianza de Animales Domésticos/métodos
11.
Med Sci Sports Exerc ; 56(6): 1196-1207, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38377012

RESUMEN

INTRODUCTION: Current wearables that collect heart rate and acceleration were not designed for children and/or do not allow access to raw signals, making them fundamentally unverifiable. This study describes the creation and calibration of an open-source multichannel platform (PATCH) designed to measure heart rate and acceleration in children ages 3-8 yr. METHODS: Children (N = 63; mean age, 6.3 yr) participated in a 45-min protocol ranging in intensities from sedentary to vigorous activity. Actiheart-5 was used as a comparison measure. We calculated mean bias, mean absolute error (MAE) mean absolute percent error (MA%E), Pearson correlations, and Lin's concordance correlation coefficient (CCC). RESULTS: Mean bias between PATCH and Actiheart heart rate was 2.26 bpm, MAE was 6.67 bpm, and M%E was 5.99%. The correlation between PATCH and Actiheart heart rate was 0.89, and CCC was 0.88. For acceleration, mean bias was 1.16 mg and MAE was 12.24 mg. The correlation between PATCH and Actiheart was 0.96, and CCC was 0.95. CONCLUSIONS: The PATCH demonstrated clinically acceptable accuracies to measure heart rate and acceleration compared with a research-grade device.


Asunto(s)
Frecuencia Cardíaca , Humanos , Niño , Preescolar , Frecuencia Cardíaca/fisiología , Masculino , Femenino , Calibración , Aceleración , Dispositivos Electrónicos Vestibles , Acelerometría/instrumentación
12.
Sensors (Basel) ; 23(13)2023 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-37447879

RESUMEN

Onboard electrostatic suspension inertial sensors are important applications for gravity satellites and space gravitational-wave detection missions, and it is important to suppress noise in the measurement signal. Due to the complex coupling between the working space environment and the satellite platform, the process of noise generation is extremely complex, and traditional noise modeling and subtraction methods have certain limitations. With the development of deep learning, applying it to high-precision inertial sensors to improve the signal-to-noise ratio is a practically meaningful task. Since there is a single noise sample and unknown true value in the measured data in orbit, odd-even sub-samplers and periodic sub-samplers are designed to process general signals and periodic signals, and adds reconstruction layers consisting of fully connected layers to the model. Experimental analysis and comparison are conducted based on simulation data, GRACE-FO acceleration data, and Taiji-1 acceleration data. The results show that the deep learning method is superior to traditional data smoothing processing solutions.


Asunto(s)
Acelerometría , Monitoreo del Ambiente , Gravitación , Modelos Teóricos , Ruido , Aceleración , Acelerometría/instrumentación , Acelerometría/métodos , Simulación por Computador , Monitoreo del Ambiente/instrumentación , Monitoreo del Ambiente/métodos , Aprendizaje Profundo , Sensación de Gravedad , Nave Espacial/instrumentación
13.
Nat Commun ; 13(1): 5311, 2022 09 09.
Artículo en Inglés | MEDLINE | ID: mdl-36085341

RESUMEN

Wearable strain sensors that detect joint/muscle strain changes become prevalent at human-machine interfaces for full-body motion monitoring. However, most wearable devices cannot offer customizable opportunities to match the sensor characteristics with specific deformation ranges of joints/muscles, resulting in suboptimal performance. Adequate wearable strain sensor design is highly required to achieve user-designated working windows without sacrificing high sensitivity, accompanied with real-time data processing. Herein, wearable Ti3C2Tx MXene sensor modules are fabricated with in-sensor machine learning (ML) models, either functioning via wireless streaming or edge computing, for full-body motion classifications and avatar reconstruction. Through topographic design on piezoresistive nanolayers, the wearable strain sensor modules exhibited ultrahigh sensitivities within the working windows that meet all joint deformation ranges. By integrating the wearable sensors with a ML chip, an edge sensor module is fabricated, enabling in-sensor reconstruction of high-precision avatar animations that mimic continuous full-body motions with an average avatar determination error of 3.5 cm, without additional computing devices.


Asunto(s)
Acelerometría , Aprendizaje Automático , Rango del Movimiento Articular , Dispositivos Electrónicos Vestibles , Acelerometría/instrumentación , Humanos , Movimiento (Física)
14.
PLoS One ; 17(2): e0263846, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35143555

RESUMEN

External peak power in the countermovement jump is frequently used to monitor athlete training. The gold standard method uses force platforms, but they are unsuitable for field-based testing. However, alternatives based on jump flight time or Newtonian methods applied to inertial sensor data have not been sufficiently accurate for athlete monitoring. Instead, we developed a machine learning model based on characteristic features (functional principal components) extracted from a single body-worn accelerometer. Data were collected from 69 male and female athletes at recreational, club or national levels, who performed 696 jumps in total. We considered vertical countermovement jumps (with and without arm swing), sensor anatomical locations, machine learning models and whether to use resultant or triaxial signals. Using a novel surrogate model optimisation procedure, we obtained the lowest errors with a support vector machine when using the resultant signal from a lower back sensor in jumps without arm swing. This model had a peak power RMSE of 2.3 W·kg-1 (5.1% of the mean), estimated using nested cross validation and supported by an independent holdout test (2.0 W·kg-1). This error is lower than in previous studies, although it is not yet sufficiently accurate for a field-based method. Our results demonstrate that functional data representations work well in machine learning by reducing model complexity in applications where signals are aligned in time. Our optimisation procedure also was shown to be robust can be used in wider applications with low-cost, noisy objective functions.


Asunto(s)
Acelerometría/instrumentación , Ejercicio Físico/fisiología , Atletas , Femenino , Humanos , Aprendizaje Automático , Masculino , Adulto Joven
15.
Clin Neurophysiol ; 135: 30-36, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35026538

RESUMEN

OBJECTIVE: This study aimed to develop a simple and reliable technique to assess excitation-contraction (E-C) coupling for early diagnosis of critical illness myopathy (CIM). METHODS: We prospectively performed clinical and electrophysiological examinations on patients admitted to intensive care unit (ICU). In addition to full neurological examinations and routine nerve conduction study, motor related potential (MRP) was recorded using an accelerometer attached to the base of hallux after tibial nerve stimulation, and E-C coupling time (ECCT) was measured from the latency difference between soleus compound muscle action potential (CMAP) and MRP. RESULTS: Of 41 patients evaluated, 25 met the criteria for ICU-acquired weakness, 23 of whom had CIM. The time to the first electrophysiological examination (time to first test) correlated negatively with CMAP and with MRP. Conversely, a positive correlation was observed between the time to first test and ECCT. E-C coupling impairment occurred in most of our patients with CIM by the third day of ICU admission, and prolonged ECCT could be the earliest detectable abnormality. CONCLUSIONS: The ECCT measurement is an easy and reliable technique to detect reduced muscle membrane excitability in the early stage of CIM. SIGNIFICANCE: The ECCT measured by our method using an accelerometer may be a parameter that predicts the development of CIM.


Asunto(s)
Acoplamiento Excitación-Contracción , Enfermedades Musculares/fisiopatología , Acelerometría/instrumentación , Acelerometría/métodos , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad Crítica , Diagnóstico Precoz , Electromiografía/instrumentación , Electromiografía/métodos , Potenciales Evocados Motores , Femenino , Humanos , Masculino , Persona de Mediana Edad , Músculo Esquelético/fisiopatología , Enfermedades Musculares/diagnóstico
17.
Motriz (Online) ; 28: e10220012021, 2022. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1360606

RESUMEN

Abstract Aims: This study aimed to compare the sedentary time measured using the ActiGraph GT3X accelerometer with the measurement of sitting and standing time obtained by ActivPAL inclinometers. Methods: This was a cross-sectional study conducted with a sample of 60 schoolchildren (34 males) of one elementary public school in Brazil. The students used both an ActiGraph GT3X accelerometer and an ActivPAL inclinometer, concurrently, positioned at the beginning and removed at the end of the school shift, for four days. For analysis, paired Student's t-tests, Pearson's correlation coefficients, intraclass correlation coefficients, and Bland-Altman plots were used. Results: When comparing sedentary time with sitting time, although correlated (r = 0.53; p < 0.001), the mean minutes were different (134.2 min/day in ActiGraph GT3X vs 120.3 min/day in ActivPAL; p < 0.001), with a bias of 13.9 min/day. When comparing the measurement of sedentary time with the sum of the sitting time plus standing time, different mean minutes were also observed (134.2 min/day in ActiGraph GT3X vs 177.0 min/day in ActivPAL; p < 0.001), and although the correlation was stronger (r = 0.75; p < 0.001), the bias was higher (−42.8 min/day). Conclusion: Sedentary time derived from the ActiGraph GT3X device should be used with caution to evaluate sedentary behavior in a school setting and may be interpreted only as non-moving activities (stationary behavior).


Asunto(s)
Humanos , Preescolar , Conducta Sedentaria , Posición de Pie , Estudios Transversales/instrumentación , Actigrafía/instrumentación , Acelerometría/instrumentación
18.
PLoS One ; 16(12): e0260570, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34971553

RESUMEN

To reexamine the relationship between leisure-time physical activity (LTPA) and the built environment (BE), this paper takes advantage of the massive amount of data collected by an accelerometer and GPS-based fitness mobile app. Massive LTPA data from more than 3 million users were recorded by Codoon in 500m by 500m grid cells and aggregated to 742 natural cities in mainland China. Six BE indicators were quantified using GIS at the city scale. Robust regression analysis was used to estimate the correlation between LTPA and BE. Five of six BE indicators-connectivity, road density, land use mix, points of interest density, and density of parks and squares-were significantly, positively, independently, and linearly related to LTPA in the regression analysis. The study obtains findings that are consistent with the previous literature but also provides novel insights into the important role of POI density in encouraging LTPA, as well as how the relationship between LTPA and BE varies by time of day. The study also sheds light on the embrace of new technology and new data in public health and urban studies.


Asunto(s)
Acelerometría/instrumentación , Entorno Construido , Investigación Empírica , Ejercicio Físico/fisiología , Actividades Recreativas , Aplicaciones Móviles , Aptitud Física/fisiología , Adolescente , Adulto , Distribución por Edad , Anciano , Niño , Preescolar , China , Sistemas de Información Geográfica , Geografía , Humanos , Lactante , Recién Nacido , Persona de Mediana Edad , Análisis de Regresión , Adulto Joven
19.
Sci Rep ; 11(1): 22104, 2021 11 11.
Artículo en Inglés | MEDLINE | ID: mdl-34764435

RESUMEN

This study aimed to compare the physical activity (PA) measured by a wearable sensor device (WSD) and the step count measurement, and to investigate the association between PAs and lifestyle. Data of 301 participants were collected from March 2019 to March 2021. Step counts, sedentary behavior, performance time of light/moderate/vigorous PA, METs × hour of "Locomotive" and "Household" categorized activities, and energy expenditure (EE) were measured by the WSD, respectively. Furthermore, the participants were classified into student, standing worker, and sitting worker groups. Data were analyzed using the Steel-Dwass and Pearson correlation coefficient tests. The correlation between the performance time of each PA and step count was weak, except for moderate PA. "Household" EE and step count also had a weak correlation. In the comparison of lifestyle, there was a significant difference in the mean performance time of each type of PA between the groups. Additionally, the standing worker and sitting worker groups had a significant difference in METs × hour of "Household" activities, indicating that the difference between the occupations is reflected in "Household" activities. The WSD measurement can be used to evaluate detailed individual PA, whereas the step count measurement showed weakness in the PA estimation.


Asunto(s)
Ejercicio Físico/fisiología , Actividad Motora/fisiología , Acelerometría/instrumentación , Adulto , Metabolismo Energético/fisiología , Femenino , Humanos , Estilo de Vida , Masculino , Persona de Mediana Edad , Conducta Sedentaria , Dispositivos Electrónicos Vestibles , Adulto Joven
20.
Ann Biomed Eng ; 49(12): 3189-3199, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34622314

RESUMEN

Contact sports players frequently sustain head impacts, most of which are mild impacts exhibiting 10-30 g peak head center-of-gravity (CG) linear acceleration. Wearable head impact sensors are commonly used to measure exposure and typically detect impacts using a linear acceleration threshold. However, linear acceleration across the head can substantially vary during 6-degree-of-freedom motion, leading to triggering biases that depend on sensor location and impact condition. We conducted an analytical investigation with impact characteristics extracted from on-field American football and soccer data. We assumed typical mouthguard sensor locations and evaluated whether simulated multi-directional impacts would trigger recording based on per-axis or resultant acceleration thresholding. Across 1387 impact directions, a 10g peak CG linear acceleration impact would trigger at only 24.7% and 31.8% of directions based on a 10 g per-axis and resultant acceleration threshold, respectively. Anterior impact locations had lower trigger rates and even a 30 g impact would not trigger recording in some directions. Such triggering biases also varied by sensor location and linear-rotational head kinematics coupling. Our results show that linear acceleration-based impact triggering could lead to considerable bias in head impact exposure measurements. We propose a set of recommendations to consider for sensor manufacturers and researchers to mitigate this potential exposure measurement bias.


Asunto(s)
Acelerometría/instrumentación , Fútbol Americano , Movimientos de la Cabeza , Protectores Bucales , Fútbol , Adolescente , Adulto , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Rotación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA