Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.607
Filtrar
1.
J Prosthodont ; 33(7): 684-690, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39118597

RESUMEN

PURPOSE: This in vitro study aimed to create a graded structured dental crown using 3D printing technology and investigate the fracture resistance and the adaptation of this new design. MATERIALS AND METHODS: A dental crown with a uniform thickness of 1.5 mm was designed, and the exported stereolithography file (STL) was used to manufacture 30 crowns in three groups (n = 10), solid (SC), bilayer (BL), and multilayer (ML) crowns using  3D jet printing technology. Marginal and internal gaps were measured using the silicone replica technique. Crowns were then luted to a resin die using a temporary luting agent and the fracture resistance was measured using a universal testing machine. One-way ANOVA and Tukey post hoc tests were used to compare the fracture resistance and the adaptation of crowns at a significance level of 0.05. RESULTS: Mean marginal and internal gap of the ML group were 80 and 82 mm, respectively; which were significantly (p < 0.05) smaller than BL (203 and 183 mm) and SC (318 and 221 mm) groups. The SC group showed the highest mean load at fracture (2330 N) which was significantly (p < 0.05) higher than the BL (1716 N) and ML (1516 N) groups. CONCLUSION: 3D jet printing technology provides an opportunity to manufacture crowns in a graded structure with various mechanical properties. This study provided an example of graded structured crowns and presented their fracture resistance. SC group had the highest fracture resistance; however, ML had the best marginal and internal adaptation.


Asunto(s)
Coronas , Diseño de Prótesis Dental , Análisis del Estrés Dental , Impresión Tridimensional , Diseño de Prótesis Dental/métodos , Humanos , Adaptación Marginal Dental , Ensayo de Materiales , Fracaso de la Restauración Dental , Técnicas In Vitro , Diseño Asistido por Computadora
2.
BMC Oral Health ; 24(1): 913, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39118080

RESUMEN

OBJECTIVES: This study aimed to evaluate the feasibility of monolithic zirconia laminate veneers (MZLV) compared to lithium disilicate laminate veneers (LDLV). MATERIALS AND METHODS: Sixty resin replicas, each prepared with depths of 0.5 mm, 0.7 mm, and 1 mm, were produced using a 3D printer from acrylic teeth. Laminate veneers of these thicknesses were milled from pre-sintered monolithic zirconia (3rd generation) and lithium disilicate blocks. The intaglio surface of MZLV was treated with air abrasion using 110 µm diameter silica-modified aluminium oxide particles and ceramic primer, while LDLV was etched with etchant gel and treated with the ceramic primer before cementation with resin cement. Vertical marginal discrepancy (VMD) was assessed using a stereomicroscope, and a load-to-failure test was conducted using a universal testing machine. Failure modes were evaluated macroscopically on fractured surfaces. Data were analysed statistically using Two-way ANOVA and Bonferroni correction (α = 0.05). RESULTS: LDLV samples exhibited significantly larger VMD compared to MZLV samples across all thicknesses, especially in cervical, palatal, and mean data. Within the LDLV group, load-to-fracture values for 0.7 mm and 1.0 mm thicknesses were similar, whereas for 0.5 mm thickness, it was significantly lower. In the MZLV group, load-to-fracture values were lower for 0.7 mm and 1.0 mm thicknesses compared to LDLV, but higher for 0.5 mm thickness. CONCLUSIONS: Material choice and restoration thickness significantly influence laminate veneer restorations' success. MZLV generally exhibits superior vertical marginal fit compared to LDLV, with varying load-to-failure values across different thicknesses. Clinical management of debonding in MZLV is simpler compared to restoration fracture in LDLV. CLINICAL RELEVANCE: Considering clinical factors, MZLV may be a preferable option to LDLV for this restoration with the thickness of 0.5 mm.


Asunto(s)
Adaptación Marginal Dental , Porcelana Dental , Coronas con Frente Estético , Circonio , Porcelana Dental/química , Circonio/química , Humanos , Ensayo de Materiales , Análisis del Estrés Dental , Fracaso de la Restauración Dental , Propiedades de Superficie , Materiales Dentales/química , Diseño de Prótesis Dental
3.
BMC Oral Health ; 24(1): 908, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39113006

RESUMEN

BACKGROUND: Effect of aging on tissue adaptability and retention of digital obturator is still under investigation. METHODS: A maxillary Armany (class I) epoxy reference model was scanned to fabricate digital obturator fabricated from milled Co-Cr framework and 3D printed bulb. A color map of the scanned reference and digital obturator was made using Geomagic software to evaluate the accuracy of fit before and after cyclic loading using ROBOTA chewing simulator at 37,500, 75,000 and 150,000 cycles to simulate clinically 3-, 6- and 12-months chewing condition. Insertion-removal condition simulating the placement and removal of the obturator was done using repeated 360, 720 and 1440 cycles and retention was evaluated before and after the repeated cycles. Data were collected, tabulated and statistically analyzed using Statistical Package for Social Sciences (IBM SPSS Statistics 26). Student t-test and multi variable ANOVA test were used to detect significance. P-value < 0.05 was considered significant difference. RESULTS: For retention test: There was a significant difference between baseline and 3, 6 and12 months. For the tissue surface adaptation test: There was significant difference at all measured areas (P-value < 0.05) before and after application of load. CONCLUSION: digitally designed and fabricated obturator was highly retentive and has excellent tissue surface adaptation upon fabrication, After application of load; reduction of retention and lack of tissue adaptation were resulted. THE CLINICAL IMPLICATION: of this manuscript is that digital obturator can be used successfully with the shortcomings of loosening retention and adaptation afterwhile. So, clinical trials should investigate the clinical acceptance of these shortcomings.


Asunto(s)
Obturadores Palatinos , Humanos , Diseño de Prótesis Dental , Propiedades de Superficie , Diseño Asistido por Computadora , Impresión Tridimensional , Retención de Prótesis Dentales , Masticación/fisiología , Adaptación Marginal Dental
4.
Dent Med Probl ; 61(4): 541-548, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39121242

RESUMEN

BACKGROUND: Pit and fissure sealants are the most commonly used preventive measure against caries in permanent molars. Advancements in dental materials have led to the development of hydrophilic sealants. However, their clinical efficacy must be evaluated and compared with that of conventional hydrophobic sealants. OBJECTIVES: This study aimed to clinically evaluate and compare the retention, marginal adaptation and marginal discoloration of hydrophilic and hydrophobic pit and fissure sealants over a 12-month follow-up period. MATERIAL AND METHODS: The study was a split-mouth, double-blind, randomized controlled trial. A sample size calculation was performed, and 120 first permanent molars (60 in each group) were selected for inclusion in the study. According to the split-mouth design, the sample was randomly divided into 2 groups. Group A was treated with a hydrophilic sealant (UltraSeal® XT Hydro), while Group B was treated with a hydrophobic sealant (Conseal F). The sealants in both groups were applied in accordance with the manufacturer's instructions by a single operator. The sealants were evaluated clinically using visual and tactile methods by 2 independent examiners who were blinded to the procedure in accordance with the modified United States Public Health Service (USPHS) clinical rating system at placement and at 1, 3, 6, and 12 months. RESULTS: After 12 months of follow-up, the Conseal F sealant showed significantly better retention (p = 0.001), marginal adaptation (p = 0.023) and reduced marginal discoloration (p = 0.004) in comparison to the UltraSeal XT Hydro sealant. CONCLUSIONS: The Conseal F (hydrophobic) sealant demonstrated superior retention, marginal adaptation and marginal discoloration compared to the UltraSeal XT Hydro (hydrophilic) sealant.


Asunto(s)
Adaptación Marginal Dental , Interacciones Hidrofóbicas e Hidrofílicas , Selladores de Fosas y Fisuras , Humanos , Método Doble Ciego , Femenino , Masculino , Diente Molar , Caries Dental/prevención & control , Resinas Compuestas/uso terapéutico
5.
BMC Oral Health ; 24(1): 845, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060942

RESUMEN

BACKGROUND: The fit of a metal-ceramic restoration is essential to its long-term durability. Regarding marginal and internal fit, there is not enough information about the technologies used in the production of metal-ceramic restorations. The aim of this in vitro study is to compare, both before and after porcelain firing, the marginal, axial, axio-occlusal, and occlusal fit of metal-ceramic restorations manufactured using casting, additive or subtractive computer-aided design, and computer-aided manufacturing techniques (CAD/CAM). METHODS: CAD/CAM were used to create 50 prepared maxillary first molar-shaped Co-Cr die models, which were randomly divided into 5 groups (n = 10). Cobalt-chrome copings were produced by casting (C), hard metal milling (HM), soft metal milling (SM), selective laser melting (SLM), and selective laser sintering (SLS) techniques. Before and after porcelain firing, discrepancies of the copings were measured using the silicone replica technique. The data obtained by measurements with a stereomicroscope at x80 magnification were analyzed statistically in the SPSS program. The ROBUST three-way analysis of variance (ANOVA) method was used to compare the discrepancy values. RESULTS: There were statistically significant differences among fabrication methods (P < .001). The HM method showed the highest discrepancy (90.1 µm), and the C (63 µm) method showed the lowest discrepancy in terms of the die model- crown fit. The C, SLS, and SM methods (63 µm; 61.6 µm; 67.7 µm) were statistically similar (P > .001). The highest discrepancy was observed on the occlusal area (87.1 µm), and the lowest discrepancy was observed on the axial area (47.7 µm) of the coping. Porcelain firing had a decrease in the discrepancy values (P = .001). CONCLUSION: All CAD/CAM techniques are appropriate for clinical use; selective laser sintering and soft milling can be the more recommended methods for the compatibility of metal-porcelain restorations, as they have lower discrepancy values than the SLM and HM methods.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Porcelana Dental , Diseño de Prótesis Dental , Aleaciones de Cerámica y Metal , Aleaciones de Cerámica y Metal/química , Porcelana Dental/química , Humanos , Técnica de Colado Dental , Adaptación Marginal Dental , Técnicas In Vitro , Aleaciones de Cromo/química
6.
Clin Oral Investig ; 28(8): 430, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39012388

RESUMEN

OBJECTIVES: This in vitro study examined the marginal integrity of experimental composite materials doped with bioactive glass (BG). MATERIALS AND METHODS: Class-II MOD cavities were prepared and restored with one of the following composite materials: a commercial composite material as a reference (Filtek Supreme XTE), an experimental composite doped with BG 45S5 (C-20), and an experimental composite doped with a fluoride-containing BG (F-20). Six experimental groups (n = 8) were used, as each of the three composites was applied with (+) or without (-) a universal adhesive (Adper Scotchbond Multipurpose). All specimens were subjected to thermocycling (10,000 x, 5-55 °C) and then additionally stored in artificial saliva for eight weeks. Scanning electron micrographs of the mesial and the distal box were taken at three time points (initial, after thermocycling, and after eight weeks of storage in artificial saliva). The margins were classified as "continuous" and "non-continuous" and the percentage of continuous margins (PCM) was statistically analyzed (α = 0.05). RESULTS: In most experimental groups, thermocycling led to a significant decrease in PCM, while the additional 8-week aging had no significant effect. F-20 + performed significantly better (p = 0.005) after 8 weeks storage in artificial saliva than the reference material with adhesive, while no statistically significant differences were observed at the other two time points. C-20 + exhibited significantly better PCM than the reference material with adhesive after thermocycling (p = 0.026) and after 8 weeks (p = 0.003). CONCLUSIONS: Overall, the experimental composites with BG showed at least as good marginal adaptation as the commercial reference, with an indication of possible re-sealing of marginal gaps. CLINICAL RELEVANCE: Maintaining or improving the marginal integrity of composite restorations is important to prevent microleakage and its likely consequences such as pulp irritation and secondary caries.


Asunto(s)
Resinas Compuestas , Adaptación Marginal Dental , Restauración Dental Permanente , Vidrio , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Saliva Artificial , Propiedades de Superficie , Resinas Compuestas/química , Técnicas In Vitro , Vidrio/química , Restauración Dental Permanente/métodos , Saliva Artificial/química , Humanos , Preparación de la Cavidad Dental , Cerámica/química , Cementos de Resina/química , Fluoruros/química
7.
Braz Oral Res ; 38: e063, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39016369

RESUMEN

Computer-aided manufacturing (CAM) technology allows the use of different manufacturing techniques. This in vitro study aimed to evaluate the marginal fit of temporary restorations manufactured using conventional chairside methods, milling, and three-dimensional printing. Fifteen 3-element temporary restorations specimens were produced and categorized into three groups: non-digital, obtained using the conventional chairside method (GC); milled (GM); and three-dimensionally printed (GP). Marginal fit was assessed using scanning electron microscopy (SEM) performed under two conditions: one with only the central screw tightened, and the other with all three screws tightened. Horizontal misfit values were categorized as over-, equal-, and under-extended and qualitatively analyzed. Statistical analysis was performed using the Tukey-Kramer test (α=0.05). In the vertical assessment, three-dimensionally printed restorations demonstrated greater misfit than restorations obtained by milling and the conventional chairside method (P<0.05). In the horizontal assessment, the misfit in the GP group was significantly higher than that in the GM and GC groups. Restorations obtained using the conventional chairside method and milled provisional restorations showed more favorable results than three-dimensionally printed restorations.


Asunto(s)
Diseño Asistido por Computadora , Adaptación Marginal Dental , Diseño de Prótesis Dental , Restauración Dental Provisional , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Impresión Tridimensional , Propiedades de Superficie , Restauración Dental Provisional/métodos , Diseño de Prótesis Dental/métodos , Reproducibilidad de los Resultados , Valores de Referencia , Estadísticas no Paramétricas , Humanos
8.
J Indian Prosthodont Soc ; 24(3): 233-239, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38946505

RESUMEN

AIMS: The aim of this study was to compare the marginal fit of prefabricated occlusal veneers with computer-aided design/computer-aided manufacturing (CAD-CAM)-milled zirconia occlusal veneers in the posterior teeth. SETTINGS AND DESIGN: Forty extracted human maxillary premolars were divided into two groups of 20 each. Group 1 was prepared to receive prefabricated occlusal veneers, and Group 2 was prepared to receive CAD-CAM-milled zirconia occlusal veneers. MATERIALS AND METHODS: Prefabricated samples (Edelweiss) were selected for Group 1, whereas for Group 2, the tooth preparations were scanned, and occlusal veneers were fabricated using Exocad designing software and milling machine. After luting, both the groups were submerged in dye, sectioned, and evaluated for marginal fit and microleakage under a stereomicroscope using the microscope imaging software and its measurement tool. STATISTICAL ANALYSIS USED: Data collected were subjected to statistical analysis using SPSS 27.0. Intragroup and intergroup comparison was done using the Mann-Whitney U test. The Chi-square test was applied to check the depth of penetration of dye based on percentages. RESULTS: The marginal gap of zirconia occlusal veneers fabricated with CAD-CAM is higher compared to that of prefabricated occlusal veneers. Similarly, the depth of penetration of dye is higher in CAD-CAM-milled zirconia occlusal veneers than prefabricated occlusal veneers. CONCLUSION: The marginal fit of prefabricated occlusal veneer is better than the marginal fit of zirconia occlusal veneers fabricated with CAD-CAM. Similarly, it can also be concluded that the microleakage of prefabricated occlusal veneer is less compared to the CAD-CAM-milled zirconia occlusal veneers.


Asunto(s)
Diseño Asistido por Computadora , Adaptación Marginal Dental , Coronas con Frente Estético , Circonio , Circonio/química , Humanos , Filtración Dental , Diseño de Prótesis Dental/métodos , Técnicas In Vitro , Diente Premolar
9.
Oper Dent ; 49(4): 403-411, 2024 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-38978316

RESUMEN

BACKGROUND: Marginal adaptation and retention of endocrowns are crucial for the success and survival of endocrowns. This study aimed to investigate the effect of different materials and intracoronal depth on the retention and marginal adaptation of CAD/CAM fabricated all-ceramic endocrowns. METHODS: Thirty-six mandibular premolar teeth with an average surface area of 64.49 mm2 were prepared to receive CAM/CAM fabricated endocrowns. Samples were divided randomly and equally into groups of lithium disilicate with 2 mm intracoronal depth (LD2), lithium disilicate with 4 mm intracoronal depth (LD4), polymer infiltrated ceramic network with 2 mm intracoronal depth (PICN2) and polymer infiltrated ceramic network with 4 mm intracoronal depth (PICN4). All endocrowns were cemented using ParaCore resin cement with 14N pressure and cured for 20 seconds. Fifty measurements of absolute marginal discrepancy (AMD) were done using a stereomicroscope after cementation. After 24 hours, all samples were subjected to thermocycling before the retention test. This involved using a universal testing machine with a crosshead speed of 0.5 mm/min and applying a load of 500N. The maximum force to detach the crown was recorded in newtons and the mode of failure was identified. RESULTS: Two-way ANOVA revealed that the AMD for PICN was statistically significantly better than lithium disilicate (p=0.01). No statistically significant difference was detected in the AMD between the two intracoronal depths (p=0.72). PICN and endocrowns with 4 mm intracoronal depth had statistically significant better retention (p<0.05). 72.22% of the sample suffered from cohesive failures and 10 LD endocrowns suffered adhesive failures. CONCLUSIONS: Within the limitations of this study, we found that different materials and intracoronal depths can indeed influence the retention of CAD/CAM fabricated endocrowns. Based on the controlled setting findings, PICN was found to have better retention and better marginal adaptation than similar lithium disilicate premolar endocrowns.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Adaptación Marginal Dental , Humanos , Técnicas In Vitro , Porcelana Dental/uso terapéutico , Porcelana Dental/química , Diente Premolar , Diseño de Prótesis Dental/métodos , Cerámica/uso terapéutico , Retención de Prótesis Dentales/métodos , Cementos de Resina , Análisis del Estrés Dental
10.
Oper Dent ; 49(4): 484-494, 2024 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-38978322

RESUMEN

OBJECTIVE: Evaluate the impact of adjustment procedures - cut-out-rescan (COR) and data exchange by over-scanning (DEOS) techniques - through CAD/CAM software on the marginal fit outcome of ceramic crowns. METHODS AND MATERIALS: Twenty-eight de-identified teeth were adapted in a mandibular typodont set. Tooth #19 was prepared for a lithium disilicate crown and seven groups, G0 to G6 (n=10), were created based on the rescanned areas (mesial and/or buccal) on the typodont using an intraoral scanner through COR or DEOS techniques. A digital workflow was used to design and mill 70 crowns according to the groups. Each crown was temporarily cemented on tooth #19 and scanned with micro-computed tomography to measure the marginal fit. The data were analyzed statistically by the Kruskal-Wallis test followed by the Mann-Whitney test to compare the groups pairwise as a post-hoc (α=0.05). RESULTS: Statistically significant differences were found for vertical misfit (µm) between the groups for Marginal Gap Buccal (MGB) and Marginal Gap Mesial (MGM) (p=0.003 and p=0.029, respectively). No significant difference was found for Finish Line Buccal (FLB) and Finish Line Mesial (FLM) (p=0.062 and p=0.092, respectively). G3 (COR buccal and mesial) had the highest MGB (57.75 µm), statistically different from all other groups. G4 (DEOS buccal) (41.60 µm) was different from G6 (DEOS buccal and mesial) (44.21 µm) (p=0.023). For MGM, G0 (control) (53.96 µm) was different from G5 (DEOS mesial) (45.76 µm) and G6 (DEOS buccal and mesial) (48.56 vm) (p=0.013 and p=0.041, respectively) and G2 (COR mesial) (58.43 µm) was different from G5 (DEOS mesial) (45.76 µm) (p=0.016). CONCLUSIONS: Despite a statistically significant difference in certain groups for both techniques, COR and DEOS techniques are viable options for image editing during acquisition. Lithium disilicate crowns can be produced with satisfactory marginal gap values utilizing a chairside CAD/CAM system.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Adaptación Marginal Dental , Porcelana Dental , Diseño de Prótesis Dental , Humanos , Diseño de Prótesis Dental/métodos , Microtomografía por Rayos X/métodos
11.
BMC Oral Health ; 24(1): 852, 2024 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-39068402

RESUMEN

BACKGROUND: Interim crowns are utilized for restoring implants during and after the process of osseointegration. However, studies on adaptation and fracture strength of implant-supported interim crowns are rare. AIM OF THE STUDY: The aim of this in vitro study is evaluating marginal fit and fracture resistance of conventional, subtractive, and additive methods of fabricating implant-supported interim crowns. MATERIALS AND METHODS: An implant was placed in an epoxy resin model with a missing first molar. A scan body was attached, and scanned with an intraoral scanner (IOS), the STL file was used to fabricate eighteen master models with standardized implant digital analogue spaces. The digital analogues and their corresponding abutments were attached to the master models and scanned with the IOS, the STL files were used to fabricate eighteen crowns using three different techniques (n = 6): conventional (CR); from Autopolymerizing composite resin, subtractive (SM); milled from PMMA resin blanks, and additive (AM); from 3D printed resin material. The crowns were fitted and cemented on their corresponding abutments and subjected to cyclic loading and thermocycling. The marginal fit was evaluated using a stereomicroscope. The crowns were then loaded until fractured in a universal testing machine. The Shapiro-Wilk and the Kolmogorov-Smirnov tests revealed that data of Marginal gap was non-parametric. Kruskal-Wallis test followed by the Dunn test was used (α = 0.05). While data of Fracture resistance test was parametric. ANOVA (F-test) was used followed by the Tukey test (α = 0.05). RESULTS: For marginal gap, a significant difference was shown between the study groups (P = .001) according to Kruskal-Wallis test. Groups SM and AM had significantly lower marginal gap values compared to group CR (P = .003). No significant difference was found between groups SM and AM (P = .994). For fracture resistance, One-way ANOVA revealed a significant difference in fracture resistance between study groups (P < .001). Group SM had significantly higher fracture strength followed by group AM and group CR (P = .001). CONCLUSIONS: Group SM and AM showed better marginal adaptation than group CR. Group SM showed superior fracture resistance compared to other groups. All study groups showed acceptable marginal gap and fracture resistance.


Asunto(s)
Coronas , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Humanos , Técnicas In Vitro , Adaptación Marginal Dental , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Diseño Asistido por Computadora , Ensayo de Materiales
12.
Am J Dent ; 37(3): 115-120, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38899989

RESUMEN

PURPOSE: To evaluate the effect of two resin composites (with different viscosities) and the elevation amount on fracture strength and fracture behavior of molars with and without deep margin elevations (DME). METHODS: 70 extracted, caries-free human molars were selected. All teeth were prepared as MOD onlay cavities with a margin 2 mm below the cemento-enamel junction (CEJ) on the mesial and buccal sides and 2 mm above the CEJ on the distal side. The teeth were divided into two groups according to the type of resin composite used in margin elevation, elevated with flowable composite (Universal Flo) or condensable composite (G-Aenial Posterior). These two groups were further subdivided into subgroups in which the elevation was 2, 3, or 4 mm, and a control group in which the non-elevated indirect restoration was directly bonded to the subgingival margin, making a total of seven groups (n= 10). After elevations, the restorations were completed using a nanoceramic CAD-CAM block (Cerasmart A3 HT) and as adhesive cement, G-Cem Link Force. Static force was applied to the restored teeth using a universal testing machine at an angle of 15° until fracture occurred. Fracture strength values were recorded, and fracture types were examined under 6x magnification. One-way ANOVA was carried out to determine the effect of DME on the fracture strength. A two-way ANOVA was conducted to investigate main and interaction effects of the material type used in the elevation and the amount of elevation made on the fracture strength (P< 0.05). RESULTS: Using flowable or condensable composite as elevation material did not affect the fracture strength of CAD-CAM restorations. Flowable and condensable composites of 2, 3, or 4 mm did not significantly affect fracture strength values for either material. Specimen margins with and without elevation exhibited similar fracture strength values. The type of material used in the elevation and the amount did not affect the fracture strength of teeth. CLINICAL SIGNIFICANCE: The deep margin elevation technique for teeth with carious lesions extending subgingivally, may be useful in routine practice.


Asunto(s)
Resinas Compuestas , Diseño Asistido por Computadora , Restauración Dental Permanente , Análisis del Estrés Dental , Humanos , Resinas Compuestas/química , Restauración Dental Permanente/métodos , Diente Molar , Fracaso de la Restauración Dental , Ensayo de Materiales , Fracturas de los Dientes , Técnicas In Vitro , Preparación de la Cavidad Dental/métodos , Materiales Dentales/química , Adaptación Marginal Dental , Cementos Dentales/química , Recubrimientos Dentinarios
13.
BMC Oral Health ; 24(1): 696, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38879492

RESUMEN

BACKGROUND: An optimum restoration for reconstructing endodontically treated teeth should provide excellent marginal adaptation, high fracture resistance as well as maximum tooth structure conservation. The purpose of this study was to evaluate the marginal adaptation and fatigue resistance of different coronal restorations in endodontically treated premolars. METHODS: Thirty sound maxillary first premolars were endodontically treated and received MOD cavities. Teeth were randomly allocated into three groups (n = 10) according to the type of coronal restoration: Group R: polyethylene fibers (ribbond), fibers-reinforced composite (everX posterior) and final layer of nano-hybrid composite. Group O: indirect lithium disilicate overlay and Group C: fiber-post, resin composite restoration, and lithium disilicate crown. Marginal gap assessment was performed before and after thermocycling (5000 cycles) using stereomicroscope. Samples were subjected to stepwise-stress loading starting at 200 N, and increased by 100 N in each step until failure occurred. Statistical analysis was done by One-way ANOVA followed Tukey`s Post Hoc test for multiple comparison. Paired t test was used to compare the marginal adaptation before and after thermocycling. Survival probability was evaluated by Life table survival analysis. Failure mode analysis was performed with Chi-square test. RESULTS: Marginal gap was significantly the lowest in group R (37.49 ± 5.05) and (42.68 ± 2.38), while being the highest in group C (59.78 ± 5.67) and (71.52 ± 5.18) in before and after thermocycling respectively (P < 0.0001). Fatigue resistance was the highest for group O (1310.8 ± 196.7), and the lowest for group R (905.4 ± 170.51) with a significant difference between groups (P < 0.0001). Crown group had the highest percentage (80%) of catastrophic failure, while, overlay group exhibited the lowest (20%). CONCLUSIONS: Direct restoration without cuspal coverage using ribbon fibers with short FRC provided better marginal adaptation than indirect overlays and crowns, but fatigue resistance wasn't significantly improved. Adhesive ceramic overlays showed the best fatigue performance and the least catastrophic failure rate compared to both direct fiber-reinforced composite and indirect ceramic full coverage restorations. CLINICAL SIGNIFICANCE: Indirect adhesive overlays are a suitable, more conservative restorative option for endodontically treated teeth than full coverage restorations, especially when tooth structure is severely compromised.


Asunto(s)
Diente Premolar , Resinas Compuestas , Coronas , Adaptación Marginal Dental , Técnica de Perno Muñón , Diente no Vital , Humanos , Resinas Compuestas/química , Técnicas In Vitro , Restauración Dental Permanente/métodos , Porcelana Dental/química , Análisis del Estrés Dental , Polietilenos/química , Fracaso de la Restauración Dental , Ensayo de Materiales , Materiales Dentales/química
14.
J Prosthet Dent ; 132(2): 422-433, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38880678

RESUMEN

STATEMENT OF PROBLEM: High-level evidence regarding the accuracy and adaptation of 1-piece endodontic crowns fabricated by using 3-dimensional (3D) printing technology is lacking. PURPOSE: The purpose of this in vitro study was to compare the accuracy and adaptation of 1-piece endodontic crowns produced through 3D printing and computer-numerical-control milling technology and to explore the influence of trueness on 1-piece endodontic crown adaptation. MATERIAL AND METHODS: One-piece endodontic crowns were prepared for a typodont right mandibular first molar, scanned with a 3Shape E3 scanner, and designed with a computer-aided design software program. Two types of 1-piece endodontic crowns were fabricated: 3D printed by using resin and zirconia slurry and milled from Grandio and zirconia blocks. A reverse engineering software program was used to superimpose 4 groups of crowns with the reference crowns used for accuracy analysis. Microcomputed tomography was used to measure 1-piece endodontic crown adaptation. The correlation between trueness and adaptation was evaluated through the Spearman correlation test (α=.05). RESULTS: Milled resin-based 1-piece endodontic crowns demonstrated better trueness on marginal and occlusal surfaces compared with 3D printed ones (P<.001). However, no significant difference was observed in the trueness of intaglio surfaces between the 2 groups (P>.05). The milled group exhibited better adaptations than the printed one (P<.05). For zirconia 1-piece endodontic crowns, no significant differences were found in trueness or adaptation between the milled and printed groups (P>.05). Notably, the trueness of the axial wall had the greatest impact on overall crown adaptation, with its adaptation closely linked to the trueness of each area, particularly the axial wall. CONCLUSIONS: Milled resin-based 1-piece endodontic crowns exhibited higher levels of trueness and adaptation compared with 3D printed ones, while 3D printed zirconia 1-piece endodontic crowns were comparable with milled ones.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Diseño de Prótesis Dental , Impresión Tridimensional , Humanos , Diseño de Prótesis Dental/métodos , Circonio , Adaptación Marginal Dental , Microtomografía por Rayos X , Técnicas In Vitro
15.
J Dent ; 148: 105154, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38942111

RESUMEN

OBJECTIVE: This study evaluated the clinical performance of Class II restorations made with flowable bulk-fill base versus conventional layering ORMOCER-based restorative material in a split-mouth randomized clinical trial. METHODS: Thirty patients received two class II restorations (n = 60) performed with different strategies. All preparations received the application of the universal self-etching adhesive system according to the manufacturer's recommendation, followed by the placement of a sectional matrix, wooden wedge, and separation ring. The first restoration was performed using 4 mm of flowable bulk-fill material covered by 2 mm of conventional viscosity restorative material (Bulk-fill technique). The second restoration was performed only with the conventional viscosity material, with a maximum of 2 mm thick increments, up to fill the cavity (Layering technique). After occlusal adjustment, the same polishing system was used for all restorations. Evaluations using the FDI criteria were conducted after 7 days, 12, and 24 months. Data were analyzed with the Fisher's Exact test (α=0.05). RESULTS: From 30 participants, 24 attended the 24-month recall, and 48 restorations were evaluated. All restorations received acceptable overall scores for esthetic and biological properties after this period, while only 6.66 % of the restorations exhibited unacceptable overall scores for the functional properties in both groups. No significant differences between the tested restorative materials and techniques were found for each FDI criterion assessed. The success rate after 2 years was 93.33 % for both groups. CONCLUSION: Both restorative materials exhibited good clinical performance for the parameters analyzed with no differences between them after 24-month follow-up. CLINICAL RELEVANCE: Flowable bulk-fill ORMOCER-based material is a suitable alternative for direct Class II restorations, providing good clinical outcomes and simplifying the restorative procedure. CLINICAL TRIAL REGISTRATION NUMBER: RBR-6mvp9w.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Restauración Dental Permanente , Humanos , Restauración Dental Permanente/métodos , Restauración Dental Permanente/clasificación , Femenino , Masculino , Resinas Compuestas/química , Resinas Compuestas/uso terapéutico , Adulto , Persona de Mediana Edad , Materiales Dentales/química , Estética Dental , Propiedades de Superficie , Viscosidad , Cerámicas Modificadas Orgánicamente , Adulto Joven , Resultado del Tratamiento , Preparación de la Cavidad Dental/clasificación , Preparación de la Cavidad Dental/métodos , Caries Dental/terapia , Pulido Dental , Adaptación Marginal Dental
16.
Am J Dent ; 37(2): 91-100, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38704852

RESUMEN

PURPOSE: To compare the internal adaptation of restorative systems bonded to mid-coronal and gingival dentin using light-cured, chemical-cured, and dual-cured adhesives, both immediately and after aging. METHODS: 60 molars were selected and received occluso-mesial preparations with dentin gingival margins. Restorations were performed using different restorative systems with light-cured, chemical-cured, and dual-cured adhesives. Internal adaptation was assessed by examining the percentage of continuous margin (%CM) at the pulpal and gingival dentin under a scanning electron microscope at x200 magnification. Half of the teeth were stored in sterile water for 24 hours, while the other half underwent 10,000 thermal cycles. Micro-morphological analysis was conducted on representative samples at x1,000 magnification. RESULTS: The restorative system with light-cured adhesive exhibited significantly lower %CM values at the gingival dentin, particularly after aging. Aging had a negative impact on the %CM values of the pulpal and gingival dentin in restorative systems with light-cured and dual-cured adhesives. Regional dentin variations influenced the %CM values, especially after aging, regardless of the restorative system used. The tested restorative system with chemical-cured adhesive is preferable for achieving improved internal adaptation when bonding to both mid-coronal and gingival dentin, compared to the other tested systems. CLINICAL SIGNIFICANCE: The study highlights the variations in adhesive performance between different regional dentin areas using the tested restorative systems.


Asunto(s)
Resinas Compuestas , Encía , Humanos , Resinas Compuestas/química , Pulpa Dental , Restauración Dental Permanente , Adaptación Marginal Dental , Microscopía Electrónica de Rastreo , Dentina , Cementos de Resina/química , Diente Molar , Técnicas In Vitro , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales
17.
Int J Prosthodont ; 37(7): 175-185, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38787582

RESUMEN

PURPOSE: To assess the manufacturing accuracy, intaglio surface adaptation, and survival of resin-based CAD/CAM definitive crowns created via additive manufacturing (AM) or subtractive manufacturing (SM). MATERIALS AND METHODS: A maxillary right first molar crown was digitally designed and manufactured using AM hybrid resin composite (VarseoSmile Crown Plus, Bego [AM-HRC]), AM glass filler-reinforced resin composite (Crowntec, Saremco Dental [AM-RC]), and SM polymer-infiltrated ceramic (Vita Enamic, VITA Zahnfabrik [SM-PICN]). Manufacturing accuracy (trueness and precision) was assessed by computing the root mean square (RMS) error (in µm; n = 15 per material). Intaglio surface adaptation was assessed by calculating the average gap distance (µm). Ten crowns from each group were cemented on fiberglass-reinforced epoxy resin dies and cyclically loaded to simulate 5 years of functional loading. One-way ANOVA, post hoc Bonferroni comparison tests, and Levene's test were used to analyze the data (α = .05). RESULTS: AM-RC had higher overall trueness than AM-HRC and SM-PICN (P ≤ .05), whereas the trueness of AM-RC on the external surface was similar to that of SM-PICN (P = .99) and higher than AM-HRC (P = .001). SM-PICN had lower precision than AM-RC and AM-HRC overall and at internal occlusal surfaces (P ≤ .05). Overall intaglio surface adaptation was similar between all groups (P = .531). However, for the axial intaglio surface, AM-RC and AM-HRC had higher adaptation than SM-PICN (P ≤ .05). All tested crowns survived the cyclic loading simulation of 5 years clinical use. CONCLUSIONS: AM-RC showed high manufacturing accuracy and adaptation. The tested resin-based CAD/CAM materials demonstrated clinically acceptable manufacturing accuracy and simulated medium-term durability, justifying the initiation of clinical investigations to determine their potential implementation in daily clinical practice.


Asunto(s)
Resinas Compuestas , Diseño Asistido por Computadora , Coronas , Diseño de Prótesis Dental , Técnicas In Vitro , Resinas Compuestas/química , Humanos , Adaptación Marginal Dental , Propiedades de Superficie , Ensayo de Materiales , Análisis del Estrés Dental , Cerámica/química , Diente Molar
18.
J Dent Res ; 103(7): 697-704, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38752325

RESUMEN

We aimed to evaluate the impact of 2 visual diagnostic strategies for assessing secondary caries and managing permanent posterior restorations on long-term survival. We conducted a diagnostic cluster-randomized clinical trial with 2 parallel groups using different diagnostic strategies: (C+AS) based on caries assessment, marginal adaptation, and marginal staining aspects of the FDI (World Dental Federation) criteria and (C) based on caries assessment using the Caries Associated with Restorations or Sealants (CARS) criteria described by the International Caries Detection and Assessment System (ICDAS). The treatment for the restoration was conducted based on the decision made following the allocated diagnostic strategy. The restorations were then clinically reevaluated for up to 71 mo. The primary outcome was restoration failure (including tooth-level failure: pain, endodontic treatment, and extraction). Cox regression analyses with shared frailty were conducted in the intention-to-treat population, and hazard ratios (HRs) and 95% confidence intervals (95% CIs) were derived. We included 727 restorations from 185 participants and reassessed 502 (69.1%) restorations during follow-up. The evaluations occurred between 6 and 71 mo. At baseline, C led to almost 4 times fewer interventions compared with the C+AS strategy. A total of 371 restorations were assessed in the C group, from which 31 (8.4%) were repaired or replaced. In contrast, the C+AS group had 356 restorations assessed, from which 113 (31.7%) were repaired or replaced. During follow-up, 34 (9.2%) failures were detected in the restorations allocated to the C group and 30 (8.4%) allocated to the C+AS group in the intention-to-treat population, with no significant difference between the groups (HR = 0.83; 95% CI = 0.51 to 1.38; P = 0.435, C+AS as reference). In conclusion, a diagnostic strategy focusing on marginal defects results in more initial interventions but does not improve longevity over the caries-focused strategy, suggesting the need for more conservative approaches.


Asunto(s)
Caries Dental , Fracaso de la Restauración Dental , Restauración Dental Permanente , Humanos , Restauración Dental Permanente/métodos , Caries Dental/terapia , Caries Dental/diagnóstico , Femenino , Masculino , Adulto , Persona de Mediana Edad , Adaptación Marginal Dental
19.
Dent Mater ; 40(6): 966-975, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38724332

RESUMEN

OBJECTIVES: Due to innumerable confounding factors and a high number of types and brands of dental restorative materials, the clinical performance of restorative materials are sought predicted by various in vitro tests. However, only few such tests have been found to correlate well with clinical findings. Thus, the present study determined the in vitro dentin bond strength and marginal adaptation of Class II restorations and correlated the results to their clinical outcomes. METHODS: Dentin bond strength (µTBS and µSBS) and marginal gap formation of Class II restorations (replica technique and SEM) were measured after 24 h and 6 m water storage using eight combinations of adhesive and resin composite. Clinical outcomes (mean survival time, Hazard Ratio, annual failure rate; n = 10.695) were gained from a data set of a retrospective multicenter study of direct restorations. RESULTS: Significant differences were found for dentin bond strength and marginal gap formation between the restorative material groups, and negative effects of long-term storage were observed. µTBS correlated significantly with certain clinical outcomes of Class I restorations, while µSBS correlated with certain clinical outcomes of Class II, III, IV and V restorations. Marginal gap formation in enamel and number of paramarginal fractures correlated with certain clinical outcomes of Class II restorations. SIGNIFICANCE: Using the same restorative materials in vitro as in vivo, gave significant, but weak correlations between in vitro bond strength or marginal adaptation and clinical outcomes, lending support to the use of in vitro tests in early stages of material selection.


Asunto(s)
Resinas Compuestas , Recubrimiento Dental Adhesivo , Adaptación Marginal Dental , Restauración Dental Permanente , Ensayo de Materiales , Resinas Compuestas/química , Humanos , Estudios Retrospectivos , Técnicas In Vitro , Resistencia a la Tracción , Análisis del Estrés Dental , Microscopía Electrónica de Rastreo , Fracaso de la Restauración Dental , Recubrimientos Dentinarios/química , Materiales Dentales/química , Propiedades de Superficie
20.
J Dent ; 147: 105080, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38788919

RESUMEN

OBJECTIVES: To evaluate the influence of dentin moisture on the clinical behavior of a universal adhesive on posterior teeth after 36 months of follow-up. METHODS: Forty-five patients participated in this study. Following a split-mouth design, three operators placed 90 Class I/Class II restorations over moist dentin (MD) or dry (DD) (n = 45) with resin composite (Filtek Bulk Fill) and a universal adhesive used in the etch-and-rinse mode (Single Bond Universal). Each restoration was evaluated according to the FDI and USPHS criteria (postoperative sensitivity, fracture and retention, marginal staining, marginal adaptation, and recurrence of caries) at baseline and after 6-, 12-, and 36 months. For statistical analysis, Kruskal Wallis analysis of variance rank (α = 0.05) and Kaplan-Meier survival analysis were used. RESULTS: No significant difference between groups was observed in each FDI criterion after 36 months of clinical evaluation (p > 0.05). The retention rates (confidence interval 95 %) were 97.37 % (86.5 - 99.5) for both MD and DD without significant difference between them (p > 0.05). Eight restorations (MD = 4; DD = 4) showed minimal marginal staining defects (p > 0.05). Two restorations were lost (MD = 1; DD = 1). Fifteen restorations (MD = 8; DD = 7) presented minor marginal discrepancies according to the FDI criteria (p > 0.05). CONCLUSION: The clinical performance of the universal adhesive when applied in etch-and-rinse mode was not influenced by dentin moisture in posterior bulk-fill composite restorations. CLINICAL SIGNIFICANCE: The level of dentin moisture appears not to influence the clinical efficacy of a universal adhesive when applied using the etch-and-rinse technique in posterior composite resin restorations.


Asunto(s)
Bisfenol A Glicidil Metacrilato , Resinas Compuestas , Caries Dental , Adaptación Marginal Dental , Fracaso de la Restauración Dental , Restauración Dental Permanente , Sensibilidad de la Dentina , Recubrimientos Dentinarios , Dentina , Cementos de Resina , Humanos , Restauración Dental Permanente/métodos , Resinas Compuestas/química , Resinas Compuestas/uso terapéutico , Femenino , Masculino , Método Doble Ciego , Adulto , Cementos de Resina/química , Persona de Mediana Edad , Bisfenol A Glicidil Metacrilato/química , Bisfenol A Glicidil Metacrilato/uso terapéutico , Caries Dental/terapia , Recubrimientos Dentinarios/química , Recubrimientos Dentinarios/uso terapéutico , Estudios de Seguimiento , Adulto Joven , Resultado del Tratamiento , Recubrimiento Dental Adhesivo/métodos , Grabado Ácido Dental
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...