Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.296
Filtrar
1.
Clin Nucl Med ; 49(8): 748-749, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38967506

RESUMEN

ABSTRACT: A 51-year-old woman with a 2-mm-Breslow-thickness melanoma on her arm had 99mTc-nanocolloid lymphoscintigraphy to localize the associated sentinel lymph node. A single axillary node was identified, and histology confirmed a micrometastasis of breast tissue origin. Imaging of the patient's breasts and subsequent biopsy confirmed ipsilateral stage III breast cancer, which was treated with lumpectomy and axillary node clearance. This is the first reported case of an incidental solid cancer diagnosis from a sentinel lymph node biopsy undertaken for a different tumor origin. This illustrates the importance of recognizing overlapping lymphatic distribution of sentinel lymph nodes, which can drain multiple organs.


Asunto(s)
Brazo , Neoplasias de la Mama , Hallazgos Incidentales , Linfocintigrafia , Melanoma , Neoplasias Cutáneas , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Humanos , Femenino , Persona de Mediana Edad , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Melanoma/diagnóstico por imagen , Melanoma/patología , Neoplasias Cutáneas/diagnóstico por imagen , Neoplasias Cutáneas/patología , Brazo/diagnóstico por imagen , Melanoma Cutáneo Maligno , Biopsia del Ganglio Linfático Centinela
2.
Int J Radiat Oncol Biol Phys ; 119(4): 1285-1296, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38925768

RESUMEN

PURPOSE: Significant improvements within radioembolization imaging and dosimetry permit the development of an accurate and personalized pretreatment plan using technetium 99m-labeled macroaggregated albumin (99mTc-MAA) and single-photon emission computed tomography (SPECT) combined with anatomical CT (SPECT/CT). Despite these potential advantages, the clinical transition to pretreatment protocols with SPECT/CT is hindered by their unknown safety constraints. This study aimed to address this issue by establishing novel dose limits for 99mTc-MAA SPECT/CT to enable quantitative pretreatment planning. METHODS AND MATERIALS: Stratification criteria to determine images most viable for dosimetry analysis were created from a cohort of 85 patients. SPECT/CT, cone beam CT, and activity calculations derived from the local deposition method were used to create an accurate pretreatment protocol. Planar and SPECT/CT images were compared using linear regression and modified Bland-Altman analyses to convert accepted planar dose limits to SPECT/CT. To validate these new dose limits, activity calculations based on SPECT/CT were compared with those calculated with the body surface area and planar methods for three treatment plans. RESULTS: A total of 38 of 85 patients were deemed viable for dosimetry analysis. SPECT yielded greater lung shunt fractions (LSFs) than planar imaging when LSFs were <4.89%, whereas SPECT yielded lower LSFs than planar imaging when LSFs were >4.89%. Planar to SPECT/CT dose conversions were 0.76×, 0.70×, and 0.55× for the whole liver, normal liver, and lungs, respectively. Patients with SPECT LSFs ≤4.89% were safely treated with the direct application of planar lung dose limits. Activity calculations with the newly established SPECT/CT dose limits were greater than those of the body surface area method by a median range of 33.1% to 61.9% and were lower than planar-based activity calculations by a median range of 12.5% to 13.7% for the whole liver and by 29.4% to 32.2% for the normal liver. CONCLUSIONS: This study demonstrated a safe method for translating dose limits from 99mTc-MAA planar imaging to SPECT/CT. A robust pretreatment protocol was further developed guided by the current knowledge in the field. Established SPECT/CT dose limits safely treated 97.5% of patients and permitted the application of independent pretreatment planning with 99mTc-MAA SPECT/CT.


Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Humanos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Embolización Terapéutica/métodos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Femenino , Anciano , Persona de Mediana Edad , Planificación de la Radioterapia Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/normas , Radiofármacos , Anciano de 80 o más Años , Superficie Corporal , Tomografía Computarizada de Haz Cónico/métodos
3.
HPB (Oxford) ; 26(7): 919-927, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38604828

RESUMEN

INTRODUCTION: This study investigates the incidence of extrahepatic perfusion and incomplete hepatic perfusion at intraoperative methylene blue testing and on postoperative nuclear imaging in patients undergoing hepatic arterial infusion pump (HAIP) chemotherapy. METHODS: The first 150 consecutive patients who underwent pump implantation in the Netherlands were included. All patients underwent surgical pump implantation with the catheter in the gastroduodenal artery. All patients underwent intraoperative methylene blue testing and postoperative nuclear imaging (99mTc-Macroaggregated albumin SPECT/CT) to determine perfusion via the pump. RESULTS: Patients were included between January-2018 and December-2021 across eight centers. During methylene blue testing, 29.3% had extrahepatic perfusion, all successfully managed intraoperatively. On nuclear imaging, no clinically relevant extrahepatic perfusion was detected (0%, 95%CI: 0.0-2.5%). During methylene blue testing, 2.0% had unresolved incomplete hepatic perfusion. On postoperative nuclear imaging, 8.1% had incomplete hepatic perfusion, leading to embolization in only 1.3%. CONCLUSION: Methylene blue testing during pump placement for intra-arterial chemotherapy identified extrahepatic perfusion in 29.3% of patients, but could be resolved intraoperatively in all patients. Postoperative nuclear imaging found no clinically relevant extrahepatic perfusion and led to embolization in only 1.3% of patients. The role of routine nuclear imaging after HAIP implantation should be studied in a larger cohort.


Asunto(s)
Arteria Hepática , Infusiones Intraarteriales , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Países Bajos/epidemiología , Arteria Hepática/diagnóstico por imagen , Azul de Metileno/administración & dosificación , Incidencia , Neoplasias Hepáticas/cirugía , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Estudios Retrospectivos , Circulación Hepática , Bombas de Infusión Implantables , Antineoplásicos/administración & dosificación , Agregado de Albúmina Marcado con Tecnecio Tc 99m/administración & dosificación
4.
Eur J Surg Oncol ; 50(6): 108340, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38653162

RESUMEN

To address the limitations of conventional sentinel lymph node biopsy (SLNB), a novel hybrid tracer (indocyanine green [ICG]-99mTc-nanocolloid) has been developed. This meta-analysis aimed to compare the differences between the novel hybrid tracer and conventional methods using ICG or radioisotope (RI) for SLNB in head and neck malignancies. This study was registered in the International Prospective Register of Systematic Reviews (CRD42023409127). PubMed, Embase, Web of Science, and the Cochrane Library were systematically searched. This study included raw data on the number of sentinel lymph nodes (SLNs) identified using different modalities during surgery for head and neck malignancies. The identification rate of SLNs was the main outcome of interest. Prognostic data and complication rate cannot be deduced from this article. The heterogeneity test (I2) determined the use of a fixed- or random-effects model for the pooled risk ratio (RR). Overall, 1275 studies were screened, of which 11 met the inclusion criteria for the meta-analysis. In SLN identification of head and neck malignancies, ICG-99mTc-nanocolloid was superior to ICG or RI. In the subgroup analyses, the detection rates of ICG and RI tracers in SLNB were comparable, regardless of the device, tumor type, or tumor stage. In conclusion, in SLN identification of head and neck malignancies, the use of ICG-99mTc-nanocolloid is superior to the single technique of ICG or RI. This study suggests that Hospitals using ICG or RI may find it beneficial to change their practice to ICG-99mTc-nanocolloid, especially in the head and neck area, owing to its superior effectiveness.


Asunto(s)
Neoplasias de Cabeza y Cuello , Biopsia del Ganglio Linfático Centinela , Humanos , Colorantes , Neoplasias de Cabeza y Cuello/patología , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/cirugía , Verde de Indocianina , Metástasis Linfática , Radiofármacos , Ganglio Linfático Centinela/patología , Ganglio Linfático Centinela/diagnóstico por imagen , Biopsia del Ganglio Linfático Centinela/métodos , Agregado de Albúmina Marcado con Tecnecio Tc 99m
5.
Hell J Nucl Med ; 27(1): 55-57, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38629817

RESUMEN

The hepatopulmonary syndrome (HPS) is characterized by arterial oxygenation defect induced by intrapulmonary vascular dilatations in the setting of liver disease. We report a 57-year-old woman with a history of liver cirrhosis presented with progressive cyanosis, exertional dyspnea and a dry cough. Oxyhemoglobin saturation was 88.5% on room air. Contrast transthoracic echocardiography (cTTE) and technetium-99m-macroaggregated albumin (99mTc-MAA) scintigraphy showed an intrapulmonary shunting and confirmed HPS.


Asunto(s)
Ecocardiografía , Síndrome Hepatopulmonar , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Humanos , Síndrome Hepatopulmonar/diagnóstico por imagen , Síndrome Hepatopulmonar/complicaciones , Femenino , Persona de Mediana Edad , Ecocardiografía/métodos , Cintigrafía/métodos , Radiofármacos
6.
Cardiovasc Intervent Radiol ; 47(4): 443-450, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38326577

RESUMEN

PURPOSE: Radiation pneumonitis is a serious complication of radioembolization. In holmium-166 ([166Ho]) radioembolization, the lung mean dose (LMD) can be estimated (eLMD) using a scout dose with either technetium-99 m-macroaggregated albumin ([99mTc]MAA) or [166Ho]-microspheres. The accuracy of eLMD based on [99mTc]MAA (eLMDMAA) was compared to eLMD based on [166Ho]-scout dose (eLMDHo-scout) in two prospective clinical studies. MATERIALS AND METHODS: Patients were included if they received both scout doses ([99mTc]MAA and [166Ho]-scout), had a posttreatment [166Ho]-SPECT/CT (gold standard) and were scanned on the same hybrid SPECT/CT system. The correlation between eLMDMAA/eLMDHo-scout and LMDHo-treatment was assessed by Spearman's rank correlation coefficient (r). Wilcoxon signed rank test was used to analyze paired data. RESULTS: Thirty-seven patients with unresectable liver metastases were included. During follow-up, none developed symptoms of radiation pneumonitis. Median eLMDMAA (1.53 Gy, range 0.09-21.33 Gy) was significantly higher than median LMDHo-treatment (0.00 Gy, range 0.00-1.20 Gy; p < 0.01). Median eLMDHo-scout (median 0.00 Gy, range 0.00-1.21 Gy) was not significantly different compared to LMDHo-treatment (p > 0.05). In all cases, eLMDMAA was higher than LMDHo-treatment (p < 0.01). While a significant correlation was found between eLMDHo-scout and LMDHo-treatment (r = 0.43, p < 0.01), there was no correlation between eLMDMAA and LMDHo-treatment (r = 0.02, p = 0.90). CONCLUSION: [166Ho]-scout dose is superior in predicting LMD over [99mTc]MAA, in [166Ho]-radioembolization. Consequently, [166Ho]-scout may limit unnecessary patient exclusions and avoid unnecessary therapeutic activity reductions in patients eligible for radioembolization. TRAIL REGISTRATION: NCT01031784, registered December 2009. NCT01612325, registered June 2012.


Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas , Neumonitis por Radiación , Humanos , Estudios Prospectivos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Tomografía Computarizada de Emisión de Fotón Único , Neumonitis por Radiación/etiología , Neumonitis por Radiación/tratamiento farmacológico , Radioisótopos de Itrio/uso terapéutico , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Embolización Terapéutica/efectos adversos , Pulmón/diagnóstico por imagen , Microesferas , Estudios Retrospectivos
7.
Cancer Biother Radiopharm ; 39(5): 330-336, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38265813

RESUMEN

Purpose: This study evaluated the effect of an increase in the time interval between hepatic intra-arterial injection of 99mTc-macroaggregated albumin (MAA) and hepatic artery perfusion scintigraphy (HAPS) on the lung shunt fraction (LSF) and perfused volume (PV) calculations in the treatment planning of selective internal radiation therapy (SIRT). Methods: The authors enrolled 51 HAPS sessions from 40 patients diagnosed with primary or metastatic liver malignancy. All patients underwent scan at the first and fourth hour after hepatic arterial injection of 99mTc-MAA. Based on single-photon emission computed tomography images, LSF values were measured from each patient's first and fourth hour images. PV1 and PV4 were also calculated based on three-dimensional images using 5% and 10% cutoff threshold values and compared with each other. Results: The authors found that the median of LSF4 was statistically significantly higher than LSF1 (3.05 vs. 4.14, p ≤ 0.01). There was no statistically significant difference between PV1 and PV4 on the 10% (p = 0.72) thresholds. Conclusions: LSF values can be overestimated in case of delayed HAPS, potentially leading to treatment cancellation due to incorrectly high results in patients who could benefit from SIRT. Threshold-based PV values do not significantly change over time; nevertheless, keeping the short interval time would be safer.


Asunto(s)
Arteria Hepática , Neoplasias Hepáticas , Imagen de Perfusión , Radioisótopos de Itrio , Humanos , Arteria Hepática/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/secundario , Anciano , Radioisótopos de Itrio/uso terapéutico , Imagen de Perfusión/métodos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Planificación de la Radioterapia Asistida por Computador/métodos , Adulto , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano de 80 o más Años , Radiofármacos/administración & dosificación
8.
Curr Radiopharm ; 17(3): 276-284, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38288829

RESUMEN

INTRODUCTION: The most important toxicity of transarterial radioembolization therapy applied in liver malignancies is radiation pneumonitis and fibrosis due to hepatopulmonary shunt of Yttrium-90 (90Y) microspheres. Currently, Technetium-99m macroaggregated albumin (99mTc-MAA) scintigraphic images are used to estimate lung shunt fraction (LSF) before treatment. The aim of this study was to create a phantom to calculate exact LFS rates according to 99mTc activities in the phantom and to compare these rates with LSF values calculated from scintigraphic images. MATERIALS AND METHODS: A 3D-printed lung and liver phantom containing two liver tumors was developed from Polylactic Acid (PLA) material, which is similar to the normal-sized human body in terms of texture and density. Actual %LSFs were calculated by filling phantoms and tumors with 99mTc radionuclide. After the phantoms were placed in the water tank made of plexiglass material, planar, SPECT, and SPECT/CT images were obtained. The actual LSF ratio calculated from the activity amounts filled into the phantom was used for the verification of the quantification of scintigraphic images and the results obtained by the Simplicity90YTM method. RESULTS: In our experimental model, LSFs calculated from 99mTc activities filled into the lungs, normal liver, small tumor, and large tumor were found to be 0%, 6.2%, 10.8%, and 16.9%. According to these actual LSF values, LSF values were calculated from planar, SPECT/CT (without attenuation correction), and SPECT/CT (with both attenuation and scatter correction) scintigraphic images of the phantom. In each scintigraphy, doses were calculated for lung, small tumor, large tumor, normal liver, and Simplicity90YTM. The doses calculated from planar and SPECT/CT (NoAC+NoSC) images were found to be higher than the actual doses. The doses calculated from SPECT/CT (with AC+with SC) images and Simplicity90YTM were found to be closer to the real dose values. CONCLUSION: LSF is critical in dosimetry calculations of 90Y microsphere therapy. The newly introduced hepatopulmonary shunt phantom in this study is suitable for LSF verification for all models/brands of SPECT and SPECT/CT devices.


Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas , Fantasmas de Imagen , Radiofármacos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Radioisótopos de Itrio , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagen , Embolización Terapéutica/métodos , Radiofármacos/uso terapéutico , Radioisótopos de Itrio/uso terapéutico , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Microesferas , Pulmón/diagnóstico por imagen , Pulmón/efectos de la radiación , Impresión Tridimensional , Hígado/diagnóstico por imagen
9.
J Vasc Interv Radiol ; 35(5): 689-698.e3, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38246416

RESUMEN

PURPOSE: To characterize estimated mean absorbed tumor dose (ADT), objective response (OR), and estimated target dose of hepatocellular carcinoma (HCC) after resin microsphere yttrium-90 (90Y) radioembolization using partition dosimetry. MATERIALS AND METHODS: In this retrospective, single-center study, multicompartment dosimetry of index tumors receiving 90Y radioembolization between October 2015 and June 2022 was performed using a commercial software package and pretreatment technetium-99m macroaggregated albumin single photon emission computed tomography (SPECT)/computed tomography (CT). In total, 101 patients with HCC underwent 102 treatments of 127 index tumors. Patients underwent imaging every 2-3 months after treatment to determine best response per modified Response Evaluation Criteria in Solid Tumors (mRECIST). Best response was defined as the greatest response category per mRECIST and categorized as OR or nonresponse (NR). A Cox proportional hazards model evaluated the probability of tumor OR and progression-free survival using ADT. RESULTS: The median follow-up period was 148 days (interquartile range [IQR], 92-273 days). The median ADT of OR was 141.9 Gy (IQR, 89.4-215.8 Gy) compared with the median ADT of NR treatments of 70.8 Gy (IQR, 42.0-135.3 Gy; P < .001). Only ADT was predictive of response (hazard ratio = 2.79 [95% confidence interval {CI}: 1.44-5.40]; P = .003). At 6 months, an ADT of 157 Gy predicted 90.0% (95% CI: 41.3%-98.3%) probability of OR. At 1 year, an ADT of 157 Gy predicted 91.6% (95% CI: 78.3%-100%) probability of progression-free survival. Partition modeling and delivered activity were predictive of progression (P = .021 and P = .003, respectively). CONCLUSIONS: For HCC treated with resin microspheres, tumors receiving higher ADT exhibited higher rates of OR. An ADT of 157 Gy predicted 90.0% OR at 6 months.


Asunto(s)
Carcinoma Hepatocelular , Embolización Terapéutica , Neoplasias Hepáticas , Microesferas , Valor Predictivo de las Pruebas , Radiofármacos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Radioisótopos de Itrio , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/mortalidad , Estudios Retrospectivos , Radioisótopos de Itrio/administración & dosificación , Radioisótopos de Itrio/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , Radiofármacos/administración & dosificación , Radiofármacos/efectos adversos , Anciano , Embolización Terapéutica/efectos adversos , Agregado de Albúmina Marcado con Tecnecio Tc 99m/administración & dosificación , Resultado del Tratamiento , Factores de Tiempo , Planificación de la Radioterapia Asistida por Computador , Anciano de 80 o más Años , Programas Informáticos , Dosificación Radioterapéutica , Adulto
10.
J Vasc Interv Radiol ; 35(1): 94-101, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37783268

RESUMEN

PURPOSE: To calculate the preradioembolic tumor-to-normal (T:N) ratio in hepatocellular carcinoma (HCC) using 2-dimensional (2D) perfusion angiography and compare it with that calculated using technetium-99m macroaggregated albumin (99mTc MAA) single-photon emission computed tomography (SPECT)/computed tomography (CT). MATERIALS AND METHODS: This prospective single-arm study enrolled 15 participants with HCC who underwent 2D perfusion angiography immediately before the enrollment and with the microcatheter located at the same location as 99mTc MAA injection, after which SPECT/CT was performed. Quantitative digital subtraction angiography was used to calculate the area under the curve for the tumor and normal hepatic parenchyma and subsequently calculate the T:N ratio. The T:N ratio was calculated from the 99mTc MAA SPECT/CT and post-yttrium-90 bremsstrahlung SPECT/CT using dosimetry software. RESULTS: The mean participant age was 64.1 years ± 9.8, and the study included 14 (93%) men and 1 (7%) woman. The mean tumor size was 4.1 cm (SD ± 2.4), and all participants received segmental treatments with glass microspheres. The mean T:N ratio calculated by 99mTc MAA SPECT/CT was 2.28 (SD ± 0.89) vs 2.25 (SD ± 0.99) calculated by 2D perfusion angiography (P = .45). For the 13 participants who underwent selective internal radiation therapy (transarterial radioembolization), there was no significant difference between the T:N ratios calculated by 2D perfusion angiography and post-90Y SPECT/CT (2.25 [SD ± 1.05] vs 1.91 [SD ± 0.39]; P = .12). CONCLUSIONS: The T:N ratio calculated by 2D perfusion angiography correlated well with that calculated by 99mTc MAA SPECT/CT.


Asunto(s)
Carcinoma Hepatocelular , Embolización Terapéutica , Neoplasias Hepáticas , Masculino , Femenino , Humanos , Persona de Mediana Edad , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Estudios Prospectivos , Tecnecio , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/patología , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Radioisótopos de Itrio , Albúminas , Angiografía de Substracción Digital , Perfusión , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Microesferas
11.
Radiol Phys Technol ; 17(1): 165-175, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38032506

RESUMEN

This study aimed to evaluate a deep learning-based attenuation correction (AC) method to generate pseudo-computed tomography (CT) images from non-AC single-photon emission computed tomography images (SPECTNC) for AC in 99mTc-galactosyl human albumin diethylenetriamine pentaacetic acid (GSA) scintigraphy and to reduce patient dosage. A cycle-consistent generative network (CycleGAN) model was used to generate pseudo-CT images. The training datasets comprised approximately 850 liver phantom images obtained from SPECTNC and real CT images. The training datasets were then input to CycleGAN, and pseudo-CT images were output. SPECT images with real-time CT attenuation correction (SPECTCTAC) and pseudo-CT attenuation correction (SPECTGAN) were acquired. The difference in liver volume between real CT and pseudo-CT images was evaluated. Total counts and uniformity were then used to evaluate the effects of AC. Additionally, the similarity coefficients of SPECTCTAC and SPECTGAN were assessed using a structural similarity (SSIM) index. The pseudo-CT images produced a lower liver volume than the real CT images. SPECTCTAC exhibited a higher total count than SPECTNC and SPECTGAN, which were approximately 60% and 7% lower, respectively. The uniformities of SPECTCTAC and SPECTGAN were better than those of SPECTNC. The mean SSIM value for SPECTCTAC and SPECTGAN was 0.97. We proposed a deep learning-based AC approach to generate pseudo-CT images from SPECTNC images in 99mTc-GSA scintigraphy. SPECTGAN with AC using pseudo-CT images was similar to SPECTCTAC, demonstrating the possibility of SPECT/CT examination with reduced exposure to radiation.


Asunto(s)
Aprendizaje Profundo , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Pentetato de Tecnecio Tc 99m , Humanos , Hígado/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X
12.
Eur Radiol ; 34(4): 2212-2222, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37673964

RESUMEN

OBJECTIVES: To compare the efficacy of computed tomography volumetry (CTV), technetium99m galactosyl-serum-albumin (99mTc-GSA) scintigraphy, and gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid-enhanced MRI (EOB-MRI) in estimating the liver fibrosis (LF) stage in patients undergoing liver resection. METHODS: This retrospective study included 91 consecutive patients who had undergone preoperative dynamic CT and 99mTc-GSA scintigraphy. EOB-MRI was performed in 76 patients. CTV was used to measure the total liver volume (TLV), spleen volume (SV), normalised to the body surface area (BSA), and liver-to-spleen volume ratio (TLV/SV). 99mTc-GSA scintigraphy provided LHL15, HH15, and GSA indices. The liver-to-spleen ratio (LSR) was calculated in the hepatobiliary phase of EOB-MRI. Hyaluronic acid and type 4 collagen levels were measured in 65 patients. Logistic regression and receiver operating characteristic (ROC) analyses were performed to identify useful parameters for estimating the LF stage and laboratory data. RESULTS: According to the multivariable logistic regression analysis, SV/BSA (odds ratio [OR], 1.01; 95% confidence interval [CI], 1.003-1.02; p = 0.011), LSR (OR, 0.06; 95%CI, 0.004-0.70; p = 0.026), and hyaluronic acid (OR, 1.01; 95%CI, 1.001-1.02; p = 0.024) were independent variables for severe LF (F3-4). Combined SV/BSA, LSR, and hyaluronic acid correctly estimated severe LF, with an AUC of 0.91, which was significantly larger than the AUCs of the GSA index (AUC = 0.84), SV/BSA (AUC = 0.83), or LSR (AUC = 0.75) alone. CONCLUSIONS: Combined CTV, EOB-MRI, and hyaluronic acid analyses improved the estimation accuracy of severe LF compared to CTV, EOB-MRI, or 99mTc-GSA scintigraphy individually. CLINICAL RELEVANCE STATEMENT: The combined analysis of spleen volume on CT volumetry, liver-to-spleen ratio on gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid-enhanced MRI, and hyaluronic acid can identify severe liver fibrosis associated with a high risk of liver failure after hepatectomy and recurrence in patients with hepatocellular carcinoma. KEY POINTS: • Spleen volume of CT volumetry normalised to the body surface area, liver-to-spleen ratio of EOB-MRI, and hyaluronic acid were independent variables for liver fibrosis. • CT volumetry and EOB-MRI enable the detection of severe liver fibrosis, which may correlate with post-hepatectomy liver failure and complications. • Combined CT volumetry, gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid-enhanced MRI (EOB-MRI), and hyaluronic acid analyses improved the estimation of severe liver fibrosis compared to technetium99m galactosyl-serum-albumin scintigraphy.


Asunto(s)
Fallo Hepático , Neoplasias Hepáticas , Poliaminas , Humanos , Tecnecio , Albúmina Sérica , Estudios Retrospectivos , Gadolinio , Ácido Hialurónico , Radiofármacos , Neoplasias Hepáticas/diagnóstico por imagen , Pruebas de Función Hepática , Hígado/diagnóstico por imagen , Hígado/cirugía , Hígado/patología , Cintigrafía , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Pentetato de Tecnecio Tc 99m , Cirrosis Hepática/patología , Hepatectomía , Tomografía Computarizada por Rayos X , Imagen por Resonancia Magnética/métodos
13.
Clin Nucl Med ; 49(1): 23-26, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37991434

RESUMEN

PURPOSE OF THE REPORT: Localization techniques are needed to facilitate resection of nonpalpable lesions. In this study, the feasibility of radio-guided occult lesion localization (ROLL) with 99m Tc is investigated for the localization of nonpalpable, small, suspicious, or proven melanoma or soft tissue sarcoma lesions at various locations throughout the body. PATIENTS AND METHODS: Patients with nonpalpable, suspicious, or proven melanoma or soft tissue sarcoma lesions were selected for this study. Within 24 hours before surgery, a median dose of 33.92 MBq 99m Tc-labeled human albumin particles ( 99m Tc-NA or 99m Tc-MAA) was injected in the lesion under ultrasound guidance. A hand-held gamma probe was used to detect the radioactive signal and guidance during surgery. RESULTS: In this study, 20 patients with a total of 25 lesions were included and analyzed. The median size of the lesions was 1.8 cm (interquartile range [IQR], 1.8-4.0 cm), of which 44% were intramuscular located and 36% were subcutaneous, and 20% consisted of suspicious lymph nodes, mostly in the lower extremity. At median 4 hours (IQR, 3-6 hours) postinjection, 99m Tc ROLL showed a 100% intraoperative identification rate with proper signal identification with the gamma probe in all patients. With a median surgery time of 76 minutes (IQR, 45-157 minutes), all targeted lesions could be resected without 99m Tc-related complications, resulting in 88% microscopically margin-negative resection. No reoperations were needed for the same lesion. CONCLUSIONS: The 99m Tc ROLL procedure is feasible for the localization and excision of small, nonpalpable melanoma and soft tissue sarcoma lesions at various locations in the body.


Asunto(s)
Melanoma , Sarcoma , Neoplasias de los Tejidos Blandos , Humanos , Radiofármacos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Melanoma/diagnóstico por imagen , Estudios de Factibilidad , Sarcoma/diagnóstico por imagen , Sarcoma/cirugía , Neoplasias de los Tejidos Blandos/diagnóstico por imagen , Neoplasias de los Tejidos Blandos/cirugía
14.
Ann Nucl Med ; 38(3): 210-218, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38142421

RESUMEN

PURPOSE: This study aimed to determine the absorbed doses in the tumoral-liver and non-tumoral liver of hepatocellular carcinoma (HCC) patients undergoing radioembolization with Yttrium-90 (90Y) resin microspheres, and compared with those derived from 99mTc-MAA using the partition model. METHODS: A total of 42 HCC patients (28 males and 14 females, mean age 65 ± 11.51 years) who received 45 treatment sessions with 90Y-microspheres between 2016 and 2021 were included. Pre-treatment 99mTc-MAA and post-treatment 90Y-bremsstrahlung SPECT/CT were acquired for each patient. Semi-automated segmentation of regions of interest (ROIs) was performed using MIM Encore software to determine the tumor-liver ratio (TLR) encompassing the liver volume, tumoral-liver, and lungs, and verified by both nuclear medicine physician and interventional radiologist. A partition dosimetry model was used to estimate the administered activity of 90Y-microspheres and the absorbed doses to the tumoral-liver and non-tumoral liver. The student's paired t test and Bland-Altman plot were used for the statistical analysis. RESULTS: The mean TLR values obtained from 99mTc-MAA SPECT/CT and 90Y-bremsstrahlung SPECT/CT were 4.78 ± 3.51 and 2.73 ± 1.18, respectively. The mean planning administered activity of 90Y-microspheres based on 99mTc-MAA SPECT/CT was 1.56 ± 0.80 GBq, while the implanted administered activity was 2.53 ± 1.23 GBq (p value < 0.001). The mean absorbed doses in the tumoral-liver estimated from 99mTc-MAA and 90Y-bremsstrahlung SPECT/CT were 127.44 ± 4.36 Gy and 135.98 ± 6.30 Gy, respectively. The corresponding mean absorbed doses in the non-tumoral liver were 34.61 ± 13.93 Gy and 55.04 ± 16.36 Gy. CONCLUSION: This study provides evidence that the administered activity of 90Y-microspheres, as estimated from 90Y-bremsstrahlung SPECT/CT, was significantly higher than that estimated from 99mTc-MAA SPECT/CT resulted in increased absorbed doses in both the tumoral-liver and non-tumoral liver. However, 99mTc-MAA SPECT/CT remains a valuable planning tool for predicting the distribution of 90Y-microspheres in liver cancer treatment.


Asunto(s)
Carcinoma Hepatocelular , Embolización Terapéutica , Neoplasias Hepáticas , Masculino , Femenino , Humanos , Persona de Mediana Edad , Anciano , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/tratamiento farmacológico , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamiento farmacológico , Microesferas , Tomografía Computarizada de Emisión de Fotón Único/métodos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Radioisótopos de Itrio/uso terapéutico , Embolización Terapéutica/métodos , Estudios Retrospectivos
15.
Cell Mol Biol (Noisy-le-grand) ; 69(10): 63-66, 2023 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-37953584

RESUMEN

Pulmonary embolism is one of the acute diseases of the respiratory system. This study investigates changes in red blood cell counts in pulmonary embolisms confirmed by scintigraphy. Counting red blood cells is essential in diseases, especially pulmonary embolism, because of the vital role of these cells.  In this study, 25 patients with pulmonary embolism were selected. A group of 25 healthy volunteers was also considered as a control. At zero, 30, 60 minutes, 24, 48, and 72 hours, blood samples were taken from both control and patient groups, and red blood cells were counted according to the standard method. After extracting technetium-99m from the molybdenum generator, this substance was added to the MAA drug kit under particular conditions. After preparation, radiopharmaceutical 99mTC-MAA with 1.5 millicuries was injected intravenously into both groups. In this study, a significant increase in the red blood cell count of the patient group was observed on the first and second days of the disease. On the third day, this count returned to normal. These changes indicate the functioning of the body's defense system and a response to reduce the complications caused by pulmonary embolism. Therefore, paying more attention to counting red blood cells in pulmonary embolism, along with other care, is recommended due to their particular function.


Asunto(s)
Embolia Pulmonar , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Humanos , Embolia Pulmonar/diagnóstico por imagen , Radiofármacos , Pulmón , Recuento de Células Sanguíneas
16.
J Cancer Res Clin Oncol ; 149(19): 17223-17229, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37801136

RESUMEN

PURPOSE: Near-infrared fluorescence imaging using indocyanine green (ICG) combined with radioactive markers has the potential to improve sentinel lymph-node (SLN) mapping in oral squamous cell carcinoma (OSCC). This study aimed to evaluate the ability of 99mTc and ICG in identifying the sentinel lymph nodes in patients with early stage OSCC. METHODS: Data were collected prospectively, and a retrospective analysis of 15 patients with early stage OSCC and a cN0 neck was performed. All patients received peritumoral injection of 99mTc the day before surgery and ICG was administered intraoperatively. Intentionally, the application of the two different tracers were done by two different physicians with varying degrees of experience. The number of identified lymph nodes positive for 99mTc and ICG, the overlap or possible discrepancies of both methods, and the time until fluorescence signals of ICG were detected were noted. RESULTS: In all patients, a 100% agreement in sentinel lymph-node identification was achieved, regardless of both the exact location of the peritumoral injection and the experience of the injecting surgeon. Time until ICG accumulation in the sentinel lymph node was consistently found to be between 1 and 3 min. CONCLUSION: ICG constitutes a viable and useful addition to 99mTc for intraoperative sentinel lymph-node detection in this study.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias de Cabeza y Cuello , Neoplasias de la Boca , Ganglio Linfático Centinela , Humanos , Verde de Indocianina , Ganglio Linfático Centinela/diagnóstico por imagen , Ganglio Linfático Centinela/cirugía , Ganglio Linfático Centinela/patología , Biopsia del Ganglio Linfático Centinela/métodos , Carcinoma de Células Escamosas/patología , Carcinoma de Células Escamosas de Cabeza y Cuello/patología , Estudios Retrospectivos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Linfocintigrafia/métodos , Neoplasias de la Boca/patología , Neoplasias de Cabeza y Cuello/patología , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Radiofármacos
17.
Eur J Nucl Med Mol Imaging ; 51(1): 245-257, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37698645

RESUMEN

PURPOSE: Investigate reproducibility of two segmentation methods for multicompartment dosimetry, including normal tissue absorbed dose (NTAD) and tumour absorbed dose (TAD), in hepatocellular carcinoma patients treated with yttrium-90 (90Y) glass microspheres. METHODS: TARGET was a retrospective investigation in 209 patients with < 10 tumours per lobe and at least one tumour ≥ 3 cm ± portal vein thrombosis. Dosimetry was compared using two distinct segmentation methods: anatomic (CT/MRI-based) and count threshold-based on pre-procedural 99mTc-MAA SPECT. In a round robin substudy in 20 patients with ≤ 5 unilobar tumours, the inter-observer reproducibility of eight reviewers was evaluated by computing reproducibility coefficient (RDC) of volume and absorbed dose for whole liver, whole liver normal tissue, perfused normal tissue, perfused liver, total perfused tumour, and target lesion. Intra-observer reproducibility was based on second assessments in 10 patients ≥ 2 weeks later. RESULTS: 99mTc-MAA segmentation calculated higher absorbed doses compared to anatomic segmentation (n = 209), 43.9% higher for TAD (95% limits of agreement [LoA]: - 49.0%, 306.2%) and 21.3% for NTAD (95% LoA: - 67.6%, 354.0%). For the round robin substudy (n = 20), inter-observer reproducibility was better for anatomic (RDC range: 1.17 to 3.53) than 99mTc-MAA SPECT segmentation (1.29 to 7.00) and similar between anatomic imaging modalities (CT: 1.09 to 3.56; MRI: 1.24 to 3.50). Inter-observer reproducibility was better for larger volumes. Perfused normal tissue volume RDC was 1.95 by anatomic and 3.19 by 99mTc-MAA SPECT, with corresponding absorbed dose RDC 1.46 and 1.75. Total perfused tumour volume RDC was higher, 2.92 for anatomic and 7.0 by 99mTc-MAA SPECT with corresponding absorbed dose RDC of 1.84 and 2.78. Intra-observer variability was lower for perfused NTAD (range: 14.3 to 19.7 Gy) than total perfused TAD (range: 42.8 to 121.4 Gy). CONCLUSION: Anatomic segmentation-based dosimetry, versus 99mTc-MAA segmentation, results in lower absorbed doses with superior reproducibility. Higher volume compartments, such as normal tissue versus tumour, exhibit improved reproducibility. TRIAL REGISTRATION: NCT03295006.


Asunto(s)
Carcinoma Hepatocelular , Embolización Terapéutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/tratamiento farmacológico , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamiento farmacológico , Estudios Retrospectivos , Reproducibilidad de los Resultados , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Tomografía Computarizada de Emisión de Fotón Único , Radioisótopos de Itrio/uso terapéutico , Microesferas , Embolización Terapéutica/efectos adversos
18.
J Vasc Interv Radiol ; 34(12): 2138-2146, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37640105

RESUMEN

PURPOSE: To characterize estimated absorbed tumor dose (ADT), objective response (OR), and estimated target dose of liver metastatic colorectal cancer (mCRC) after resin microsphere yttrium-90 (90Y) radioembolization using partition dosimetry. MATERIALS AND METHODS: In this retrospective, single-center study, multicompartment dosimetry of index tumors undergoing 90Y radioembolization from October 2013 to July 2022 was performed using MIM SurePlan and pretreatment technetium-99m macroaggregated albumin infusion data. Thirty-eight patients with mCRC underwent treatments for 59 index tumors. Patients were imaged every 2-3 months after treatment and then every 3-6 months after disease control to determine the best response per Response Evaluation Criteria in Solid Tumors 1.1. Responses were categorized as OR or nonresponse (NR). A Cox proportional hazards model evaluated the probability of tumor OR and local progression-free survival (LPFS) based on ADT. RESULTS: Patients had a median follow-up of 116 days (interquartile range [IQR], 69-231 days). The ADT was higher for OR patients than for NR patients (median, 130.8 [IQR, 85.6-239.0] vs 40.6 [IQR, 26.0-66.3] Gy; P < .001). A greater percentage of OR than NR patients were treated with activities calculated by partition modeling (54% vs 12%; P = .005). Only ADT predicted response (P = .032). At 6 months, an ADT of 120 Gy predicted a 55% (95% CI, 0.0%-89%) probability of OR. Only ADT (P = .010) and female sex (P = .014) predicted LPFS. At 1 year, an ADT of 120 Gy predicted a 70% (95% CI, 35%-100%) probability of LPFS. CONCLUSIONS: Tumor dose was the strongest predictor of OR for mCRC. Administration of an estimated 120 Gy to mCRC predicted 55% OR with 90Y resin microspheres at 6 months.


Asunto(s)
Neoplasias Colorrectales , Embolización Terapéutica , Neoplasias Hepáticas , Humanos , Femenino , Microesferas , Estudios Retrospectivos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Radioisótopos de Itrio/efectos adversos , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/métodos
19.
Sci Rep ; 13(1): 13118, 2023 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-37573346

RESUMEN

First-line selective internal radiation therapy (SIRT) showed promising outcomes in patients with uveal melanoma liver metastases (UMLM). Patient survival depends on liver's disease control. SIRT planning is essential and little is known about dosimetry. We investigated whether 99mTc-MAA-SPECT/CT dosimetry could predict absorbed doses (AD) evaluated on 90Y-PET/CT and assess the dose-response relationship in UMLM patients treated with first-line SIRT. This IRB-approved, single-center, retrospective analysis (prospectively collected cohort) included 12 patients (median age 63y, range 43-82). Patients underwent MRI/CT, 18F-FDG-PET/CT before and 3-6 months post-SIRT, and 90Y-PET/CT immediately post-SIRT. Thirty-two target lesions were included. AD estimates in tumor and non-tumor liver were obtained from 99mTc-MAA-SPECT/CT and post-SIRT 90Y-PET/CT, and assessed with Lin's concordance correlation coefficients (ρc and Cb), Pearson's coefficient correlation (ρ), and Bland-Altman analyses (mean difference ± standard deviation; 95% limits-of-agreement (LOA)). Influence of tumor characteristics and microsphere type on AD was analyzed. Tumor response was assessed according to size-based, enhancement-based and metabolic response criteria. Mean target lesion AD was 349 Gy (range 46-1586 Gy). Concordance between 99mTc-MAA-SPECT/CT and 90Y-PET/CT tumor dosimetry improved upon dose correction for the recovery coefficient (RC) (ρ = 0.725, ρc = 0.703, Cb = 0.969) with good agreement (mean difference: - 4.93 ± 218.3 Gy, 95%LOA: - 432.8-422.9). Without RC correction, concordance was better for resin microspheres (ρ = 0.85, ρc = 0.998, Cb = 0.849) and agreement was very good between predictive 99mTc-MAA-SPECT/CT and 90Y-PET/CT dosimetry (mean difference: - 4.05 ± 55.9 Gy; 95%LOA: - 113.7-105.6). After RC correction, 99mTc-MAA-SPECT/CT dosimetry overestimated AD (- 70.9 ± 158.9 Gy; 95%LOA: - 382.3-240.6). For glass microspheres, concordance markedly improved with RC correction (ρ = 0.790, ρc = 0.713, Cb = 0.903 vs without correction: ρ = 0.395, ρc = 0.244, Cb = 0.617) and 99mTc-MAA-SPECT/CT dosimetry underestimated AD (148.9 ± 267.5 Gy; 95%LOA: - 375.4-673.2). For non-tumor liver, concordance was good between 99mTc-MAA-SPECT/CT and 90Y-PET/CT dosimetry (ρ = 0.942, ρc = 0.852, Cb = 0.904). 99mTc-MAA-SPECT/CT slightly overestimated liver AD for resin (3.4 ± 3.4 Gy) and glass (11.5 ± 13.9 Gy) microspheres. Tumor AD was not correlated with baseline or post-SIRT lesion characteristics and no dose-response threshold could be identified. 99mTc-MAA-SPECT/CT dosimetry provides good estimates of AD to tumor and non-tumor liver in UMLM patients treated with first-line SIRT.


Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas , Humanos , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Retrospectivos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Radioisótopos de Itrio/uso terapéutico , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamiento farmacológico , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X , Albúminas , Embolización Terapéutica/efectos adversos , Microesferas
20.
Med Phys ; 50(11): 7003-7015, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37272198

RESUMEN

BACKGROUND: The calculation of the net administered activity (Aadmin ) in patients undergoing 90 Y-radioembolization is essential for dosimetry and radiation safety, yet current methods for measuring residual 90 Y activity are often associated with high uncertainty. Therefore, an accurate, robust, and clinically viable method for the determination of Aadmin across approved 90 Y microsphere devices is desirable. PURPOSE: We report on a novel method to determine Aadmin by leveraging the quantitative capabilities of SPECT/CT to measure 90 Y-emission in vivo from patients following 90 Y-radioembolization with glass or resin microspheres. METHODS: 90 Y-SPECT/CT attenuation-corrected count data from 147 sequential 90 Y-radioembolization patients was used for this analysis. Aadmin was calculated as part of routine clinical practice via the exposure rate differences between the initial 90 Y-vial and the 90 Y-residual jar. This served as our gold standard measure of Aadmin . Patient data for each microsphere device were separated into training and testing cohorts to first develop regression models and then to independently assess model performance. The training cohorts were divided into four groups: first, based on the microsphere device (glass or resin), and second, based on the SPECT volume used to calculate counts (the full SPECT field of view (FOV) or liver only (VOIliver )). Univariate linear regression models were generated for each group to predict Aadmin based on 90 Y-SPECT data from the training cohorts. Leave-one-out cross validation was implemented to estimate variability in model parameters. To assess performance, linear models derived from the training cohort were applied to 90 Y-SPECT data from the testing cohort. A comparison of the models between microspheres devices was also performed. RESULTS: Linear models derived from the glass and resin training cohorts demonstrated a strong, positive correlation between 90 Y-SPECT image counts and Aadmin for VOIliver and FOV with R2  > 0.98 in all cases. In the glass training cohort, model accuracy (100%-absolute mean prediction error) and precision (95% prediction intervals of mean prediction error) were 99.0% and 15.4% for the VOIliver and 99.7% and 17.5% for the FOV models, respectively. In the resin training cohort, the corresponding values were 98.6% and 16.7% for VOIliver and > 99.9% and 11.4% for the FOV models, respectively. The application of these linear models to 90 Y-SPECT data from the testing cohort showed Aadmin prediction errors to have high accuracy and precision for both microsphere devices. For the glass testing cohort, accuracy (precision) was 96.9% (19.6%) and 98.8% (21.1%) for the VOIliver and FOV models, respectively. The corresponding values for the resin training cohort were 97.3% (26.2%) and 98.5% (25.7%) for the VOIliver and FOV models, respectively. The slope of the linear models between the two microsphere devices was observed to be significantly different with resin microspheres generating 48%-49% more SPECT counts for equivalent 90 Y activity based on each device manufacturer's activity calibration process. CONCLUSION: 90 Y-SPECT image counts can reliably predict (accuracy > 95% and precision < 18%) Aadmin after 90 Y-radioembolization, with performance characteristics essentially equivalent for both glass and resin microspheres. There is a clear indication that activity calibrations are fundamentally different between the two microsphere devices.


Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas , Humanos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Radioisótopos de Itrio/uso terapéutico , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada de Emisión de Fotón Único , Radiometría , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Microesferas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...