Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.125
Filtrar
1.
Sensors (Basel) ; 24(14)2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39066140

RESUMEN

BACKGROUND: The company Ethnocare has developed the Overlay, a new pneumatic solution for managing volumetric variations (VVs) of the residual limb (RL) in transtibial amputees (TTAs), which improves socket fitting. However, the impact of the Overlay during functional tasks and on the comfort and pain felt in the RL is unknown. METHODS: 8 TTAs participated in two evaluations, separated by two weeks. We measured compensatory strategies (CS) using spatio-temporal parameters and three-dimensional lower limb kinematics and kinetics during gait and sit-to-stand (STS) tasks. During each visit, the participant carried out our protocol while wearing the Overlay and prosthetic folds (PFs), the most common solution to VV. Between each task, comfort and pain felt were assessed using visual analog scales. RESULTS: While walking, the cadence with the Overlay was 105 steps/min, while it was 101 steps/min with PFs (p = 0.021). During 35% and 55% of the STS cycle, less hip flexion was observed while wearing the Overlay compared to PFs (p = 0.004). We found asymmetry coefficients of 13.9% with the Overlay and 17% with PFs during the STS (p = 0.016) task. Pain (p = 0.031), comfort (p = 0.017), and satisfaction (p = 0.041) were better with the Overlay during the second visit. CONCLUSION: The Overlay's impact is similar to PFs' but provides less pain and better comfort.


Asunto(s)
Muñones de Amputación , Amputados , Miembros Artificiales , Extremidad Inferior , Diseño de Prótesis , Ajuste de Prótesis , Tibia , Humanos , Masculino , Persona de Mediana Edad , Anciano , Amputación Quirúrgica , Muñones de Amputación/fisiopatología , Extremidad Inferior/fisiopatología , Tibia/cirugía , Fenómenos Biomecánicos , Dolor/etiología , Sedestación , Posición de Pie , Marcha , Ajuste de Prótesis/efectos adversos , Miembros Artificiales/efectos adversos
2.
Eye Contact Lens ; 50(7): 292-296, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39078501

RESUMEN

OBJECTIVE: Scleral lenses (SLs) can be customized using traditional diagnostic lens fitting or by using image- and/or impression-based technologies. This study describes the availability and usage of SL fitting technology in patients with keratoconus. METHODS: An online survey queried practitioners on the mode of practice, country of residence, and estimated number of SL fits completed for keratoconus. Practitioners were asked whether they had access to image- and/or impression-based technology and to estimate the percentage of fits completed using diagnostic fitting, image-based technology, and impression-based technology. Access and usage of technology was compared between academic and community practices, United States and non-United States, and high-volume (≥60 SLs) and low-volume fitters. RESULTS: 423 practitioners who fit SL for keratoconus participated. Image- and impression-based technologies were more frequently available in academic practices compared with community practices and high-volume compared with low-volume practitioners ( P <0.005). Practitioners with image-based technology used it for a median [interquartile range] 5 [25]% of SL fittings; those with impression-based technology used it for 8 [9]% of fittings, and those with both types of technology used image-based devices for 12 [23]% of fittings and impression-based for 5 [8]% of fittings. CONCLUSIONS: In this study, most participants report using diagnostic lenses to fit SLs for patients with keratoconus.


Asunto(s)
Lentes de Contacto , Queratocono , Ajuste de Prótesis , Esclerótica , Queratocono/terapia , Humanos , Masculino , Femenino , Adulto , Encuestas y Cuestionarios
3.
PLoS One ; 19(7): e0301619, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38991031

RESUMEN

Changes in limb volume and shape among transtibial amputees affects socket fit and comfort. The ability to accurately measure residual limb volume and shape and relate it to comfort could contribute to advances in socket design and overall care. This work designed and validated a novel 3D laser scanner that measures the volume and shape of residual limbs. The system was designed to provide accurate and repeatable scans, minimize scan duration, and account for limb motion during scans. The scanner was first validated using a cylindrical body with a known shape. Mean volumetric errors of 0.17% were found under static conditions, corresponding to a radial spatial resolution of 0.1 mm. Limb scans were also performed on a transtibial amputee and yielded a standard deviation of 8.1 ml (0.7%) across five scans, and a 46 ml (4%) change in limb volume when the socket was doffed after 15 minutes of standing.


Asunto(s)
Amputados , Miembros Artificiales , Rayos Láser , Tibia , Humanos , Tibia/cirugía , Tibia/diagnóstico por imagen , Muñones de Amputación/diagnóstico por imagen , Imagenología Tridimensional/métodos , Diseño de Prótesis/métodos , Masculino , Ajuste de Prótesis/métodos
5.
Int J Pediatr Otorhinolaryngol ; 182: 112001, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38885546

RESUMEN

INTRODUCTION: The neural response telemetry (NRT) is a standard procedure in cochlear implantation mostly used to determine the functionality of implanted device and to check auditory nerve responds to the stimulus. Correlation between NRT measurements and subjective threshold (T) and maximum comfort (C) levels has been reported but results are inconsistent, and it is still not clear which of the NRT measurements could be the most useful in predicting fitting levels. PURPOSE: In our study we aimed to investigate which NRT measurement corresponds better to fitting levels. Impedance (IMP), Evoked Action Potential (ECAP) threshold and amplitude growth function (AGF) slope values were included in the study. Also, we tried to identify cochlear area at which the connection between NRT measurements and fitting levels would be the most pronounced. MATERIALS AND METHODS: Thirty-one children implanted with Cochlear device were included in this retrospective study. IMP, ECAP thresholds and AGF were obtained intra-operatively and 12 months after surgery at electrodes 5, 11 and 19 as representative for each part of cochlea. Subjective T and C levels were obtained 12 months after the surgery during cochlear fitting. RESULTS: ECAP thresholds obtained 12 months after surgery showed statistically significant correlation to both T and C levels at all 3 selected electrodes. IMP correlated with C levels while AGF showed tendency to correlate with T levels. However, these correlations were not statistically significant for all electrodes. CONCLUSION: ECAP threshold measurements correlated to T and C values better than AGF slope and IMP. Measurements obtained twelve months after surgery seems to be more predictive of T and C values compared to intra-operative measurements. The best correlation between ECAP threshold and T and C values was found at electrode 11 suggesting NRT measurements at mid-portion cochlear region to be the most useful in predicting fitting levels.


Asunto(s)
Umbral Auditivo , Implantación Coclear , Implantes Cocleares , Telemetría , Humanos , Implantación Coclear/métodos , Masculino , Femenino , Estudios Retrospectivos , Niño , Preescolar , Umbral Auditivo/fisiología , Nervio Coclear/fisiología , Potenciales Evocados Auditivos/fisiología , Ajuste de Prótesis/métodos , Cóclea/fisiología , Lactante
6.
Handchir Mikrochir Plast Chir ; 56(3): 201-211, 2024 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-38861975

RESUMEN

The introduction of the new generation of thumb carpometacarpal (CMC I) joint implants for the treatment of CMC I osteoarthritis has significantly broadened the scope of hand surgery in recent years. However, the technical demands of the procedure and the many details that need to be considered require appropriate training and a learning curve. To share experiences with the Touch CMC I prosthesis, we held the first German-speaking CMC I joint prosthetics user meeting in Zurich. After some basic introductory lectures on biomechanics and the principles of prosthetic fitting of the CMC I joint, the various challenges associated with CMC I joint prosthetics were discussed in interactive expert panels. Subsequently, cases were discussed in small groups under expert guidance and the respective conclusions were discussed in plenary. The main results of this symposium are summarised in this manuscript.


Asunto(s)
Articulaciones Carpometacarpianas , Prótesis Articulares , Osteoartritis , Diseño de Prótesis , Pulgar , Humanos , Masculino , Fenómenos Biomecánicos , Articulaciones Carpometacarpianas/cirugía , Osteoartritis/cirugía , Ajuste de Prótesis , Pulgar/cirugía
7.
Trends Hear ; 28: 23312165241259704, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38835268

RESUMEN

The use of in-situ audiometry for hearing aid fitting is appealing due to its reduced resource and equipment requirements compared to standard approaches employing conventional audiometry alongside real-ear measures. However, its validity has been a subject of debate, as previous studies noted differences between hearing thresholds measured using conventional and in-situ audiometry. The differences were particularly notable for open-fit hearing aids, attributed to low-frequency leakage caused by the vent. Here, in-situ audiometry was investigated for six receiver-in-canal hearing aids from different manufacturers through three experiments. In Experiment I, the hearing aid gain was measured to investigate whether corrections were implemented to the prescribed target gain. In Experiment II, the in-situ stimuli were recorded to investigate if corrections were directly incorporated to the delivered in-situ stimulus. Finally, in Experiment III, hearing thresholds using in-situ and conventional audiometry were measured with real patients wearing open-fit hearing aids. Results indicated that (1) the hearing aid gain remained unaffected when measured with in-situ or conventional audiometry for all open-fit measurements, (2) the in-situ stimuli were adjusted for up to 30 dB at frequencies below 1000 Hz for all open-fit hearing aids except one, which also recommends the use of closed domes for all in-situ measurements, and (3) the mean interparticipant threshold difference fell within 5 dB for frequencies between 250 and 6000 Hz. The results clearly indicated that modern measured in-situ thresholds align (within 5 dB) with conventional thresholds measured, indicating the potential of in-situ audiometry for remote hearing care.


Asunto(s)
Umbral Auditivo , Audífonos , Humanos , Estimulación Acústica , Ajuste de Prótesis/métodos , Reproducibilidad de los Resultados , Audiometría/métodos , Audiometría de Tonos Puros , Pérdida Auditiva/diagnóstico , Pérdida Auditiva/rehabilitación , Pérdida Auditiva/fisiopatología , Audición , Valor Predictivo de las Pruebas , Personas con Deficiencia Auditiva/rehabilitación , Personas con Deficiencia Auditiva/psicología , Diseño de Equipo , Masculino , Femenino
8.
J Vasc Surg ; 80(2): 529-536, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38777159

RESUMEN

BACKGROUND: Studies suggest that ambulation after major lower extremity amputation (LEA) is low and mortality after LEA is high. Successful prosthetic fitting after LEA has a significant quality of life benefit; however, it is unclear if there are benefits in post-LEA mortality. Our objective was to examine a contemporary cohort of patients who underwent LEA and determine if there is an association between fitting for a prosthetic and mortality. METHODS: We reviewed all patients who underwent LEA between 2015 and 2022 at two academic health care systems in a large metropolitan city. The exposure of interest was prosthetic fitting after LEA. The primary outcomes were mortality within 1 and 3 years of follow-up. Ambulation after LEA was defined as being ambulatory with or without an assistive device. Patients with prior LEA were excluded. Extended Cox models with time-dependent exposure were used to evaluate the association between prosthetic fitting and mortality at 1 and 3 years of follow-up. RESULTS: Among 702 patients who underwent LEA, the mean (SD) age was 64.3 (12.6) years and 329 (46.6%) were fitted for prosthetic. The study population was mostly male (n = 488, 69.5%), predominantly non-Hispanic Black (n = 410, 58.4%), and nearly one-fifth were non-ambulatory before LEA (n = 139 [19.8%]). Of note, 14.3% of all subjects who were nonambulatory at some point after LEA, and 28.5% of patients not ambulatory preoperatively were eventually ambulatory after LEA. The rate of death among those fitted for a prosthetic was 12.0/100 person-years at 1 year and 5.8/100 person-years at 3 years of follow-up; among those not fitted for a prosthetic, the rate of death was 55.7/100 person-years and 50.7/100 person-years at 1 and 3 years of follow-up, respectively. After adjusting for several sociodemographic data points, comorbidities, pre- or post- coronavirus disease 2019 pandemic timeframe, and procedural factors, prosthetic fitting is associated with decreased likelihood of mortality within 1 year of follow-up (adjusted hazard ratio, 0.24; 95% confidence interval, 0.14-0.40) as well as within 3 years (adjusted hazard ratio, 0.40; 95% confidence interval, 0.29-0.55). CONCLUSIONS: Prosthetic fitting is associated with improved survival, and preoperative functional status does not always predict postoperative functional status. Characterizing patient, surgical, and rehabilitation factors associated with receipt of prosthetic after LEA may improve long-term survival in these patients. Process measures employed by the Department of Veterans Affairs, such as prosthetic department evaluation of all amputees, may represent a best practice.


Asunto(s)
Amputación Quirúrgica , Miembros Artificiales , Ajuste de Prótesis , Humanos , Masculino , Femenino , Persona de Mediana Edad , Amputación Quirúrgica/mortalidad , Anciano , Estudios Retrospectivos , Factores de Riesgo , Extremidad Inferior/irrigación sanguínea , Extremidad Inferior/cirugía , Factores de Tiempo , Amputados/rehabilitación , COVID-19/mortalidad , Medición de Riesgo , Resultado del Tratamiento
9.
Otol Neurotol ; 45(6): 643-650, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38769101

RESUMEN

OBJECTIVE: This study aimed to evaluate the differences in electrically evoked compound action potential (ECAP) thresholds and postoperative mapping current (T) levels between electrode types after cochlear implantation, the correlation between ECAP thresholds and T levels, and the performance of machine learning techniques in predicting postoperative T levels. STUDY DESIGN: Retrospective case review. SETTING: Tertiary hospital. PATIENTS: We reviewed the charts of 124 ears of children with severe-to-profound hearing loss who had undergone cochlear implantation. INTERVENTIONS: We compared ECAP thresholds and T levels from different electrodes, calculated correlations between ECAP thresholds and T levels, and created five prediction models of T levels at switch-on and 6 months after surgery. MAIN OUTCOME MEASURES: The accuracy of prediction in postoperative mapping current (T) levels. RESULTS: The ECAP thresholds of the slim modiolar electrodes were significantly lower than those of the straight electrodes on the apical side. However, there was no significant difference in the neural response telemetry thresholds between the two electrodes on the basal side. Lasso regression achieved the most accurate prediction of T levels at switch-on, and the random forest algorithm achieved the most accurate prediction of T levels 6 months after surgery in this dataset. CONCLUSION: Machine learning techniques could be useful for accurately predicting postoperative T levels after cochlear implantation in children.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Aprendizaje Automático , Humanos , Implantación Coclear/métodos , Masculino , Femenino , Estudios Retrospectivos , Preescolar , Niño , Lactante , Ajuste de Prótesis/métodos , Potenciales Evocados Auditivos/fisiología
10.
Int Orthop ; 48(8): 2025-2031, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38748096

RESUMEN

PURPOSE: Templating is the first step in achieving a successful total hip arthroplasty. We hypothesize that native head size is highly correlated with implanted cup size. Therefore, the purpose of this study is to look for a correlation between sizes of the intra-operative measurement of the femoral head and the implanted cup. METHODS: This is a monocentric observational study conducted from December 2018 till January 2023. All patients admitted for a primary total hip arthroplasty were included and retrospectively reviewed. Intra-operative femoral head measurement, radiographic femoral head diameter, templated (planned) cup size, and definitive implanted cup size were recorded. RESULTS: The sample included 154 patients (85 female and 69 males) with a mean age of 66.2 ± 10.4 years. There were 157 THA cases; 82 on the right side and 75 on the left side. The native head size and acetate template on digital radiographs were the most significantly positively correlated with cup size (P < 0.0001) while the radiological head size was significantly negatively correlated with cup size (P = 0.009). The implanted cup was on average 2 ± 2 mm bigger than the native head size measured intra-operatively. CONCLUSION: The native femoral head diameter measured intra-operatively is a simple and reliable tool to help the surgeons choose the proper size of the acetabular cup, preventing complications during surgery hence optimizing results post operatively. This technique would contribute to a more ecofriendly orthopaedic reconstructive surgery.


Asunto(s)
Acetábulo , Artroplastia de Reemplazo de Cadera , Cabeza Femoral , Prótesis de Cadera , Humanos , Femenino , Masculino , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/instrumentación , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/cirugía , Cabeza Femoral/anatomía & histología , Estudios Retrospectivos , Persona de Mediana Edad , Acetábulo/cirugía , Acetábulo/diagnóstico por imagen , Acetábulo/anatomía & histología , Diseño de Prótesis , Anciano de 80 o más Años , Ajuste de Prótesis/métodos
11.
Gait Posture ; 112: 128-133, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38772124

RESUMEN

BACKGROUND: In the process of transtibial prosthetic fitting, alignment is the process of positioning the prosthetic foot relative to the residual limb. Changes in frontal plane alignment can impact knee moments during walking, which can either cause or, when aligned properly, prevent injuries. However, clinical evaluation of dynamic knee moments is challenging, limiting prosthetists' insights into dynamic joint loading. Typically, knee joint loading is assessed in static stance using the knee moment arm as a proxy for subsequent dynamic alignment. It remains uncertain if static alignment accurately represents actual dynamics during walking. RESEARCH QUESTION: Is the frontal knee moment arm in stance predictive for the knee moment arm and external knee adduction moment during gait in transtibial bone-anchored prosthesis users? METHODS: In this cross-sectional study, twenty-seven unilateral transtibial bone-anchored prosthesis users underwent data acquisition on the M-Gait instrumented treadmill. Static and dynamic measurements were conducted, and knee moment arm and external knee adduction moment were calculated. Pearson's correlation and linear regression analyses were performed to examine relationships between static and dynamic knee moment arms and external knee adduction moments. RESULTS: The static knee moment arm showed significant associations with dynamic knee moment arm at the ground reaction force peaks (First: r=0.60, r2=35%, p<0.001; Second: r=0.62, r2=38%, p=0.001) and knee adduction moment (First: r=0.42, r2=17%, p=0.030; Second: r=0.59, r2=35%, p=0.001). A 1 mm between-subject difference in static knee moment arm corresponded, on average, with a 0.9% difference in knee adduction moment at the first peak and a 1.5% difference at the second peak of the ground reaction force. SIGNIFICANCE: While static alignment is important to optimize adduction moments during stance it may only partly mitigate excessive moments during gait. The fair correlation and limited percentage of explained variance underscores the importance of dynamic alignment in optimizing the body's dynamic load during walking.


Asunto(s)
Miembros Artificiales , Marcha , Articulación de la Rodilla , Tibia , Humanos , Estudios Transversales , Masculino , Femenino , Persona de Mediana Edad , Fenómenos Biomecánicos , Articulación de la Rodilla/fisiología , Tibia/fisiología , Marcha/fisiología , Adulto , Anciano , Amputados , Caminata/fisiología , Ajuste de Prótesis
12.
Ear Hear ; 45(5): 1264-1273, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38755742

RESUMEN

OBJECTIVES: The aim of the present study was to investigate whether prediction models built by de Graaff et al. (2020 ) can be used to improve speech recognition in experienced adult postlingual implanted Cochlear CI users. de Graaff et al. (2020 ) found relationships between elevated aided thresholds and a not optimal electrical dynamic range (<50 CL or >60 CL), and poorer speech recognition in quiet and in noise. The primary hypothesis of the present study was that speech recognition improves both in quiet and in noise when the sound processor is refitted to match targets derived from the prediction models from de Graaff et al. (2020 ). A second hypothesis was that subjectively, most of the CI users would find the new setting too loud because of an increase in C levels, and therefore, prefer the old settings. DESIGN: A within-participant repeated measures design with 18 adult Cochlear CI users was used. T- and C-levels were changed to "optimized settings," as predicted by the model of de Graaff et al. (2020 ). Aided thresholds, speech recognition in quiet, and speech recognition in noise were measured with the old settings and after a 4-week acclimatization period with the optimized settings. Subjective benefit was measured using the Device Oriented Subjective Outcome Scale questionnaire. RESULTS: The mean electrical dynamic range changed from 41.1 (SD = 6.6) CL to 48.6 (SD = 3.0) CL. No significant change in aided thresholds was measured. Speech recognition improved for 16 out of 18 participants and remained stable for 2 participants. Average speech recognition scores in quiet significantly improved by 4.9% (SD = 3.8%). No significant change for speech recognition in noise was found. A significant improvement in subjective benefit was found for one of the Device Oriented Subjective Outcome subscales (speech cues) between the old and optimized settings. All participants chose to keep the optimized settings at the end of the study. CONCLUSIONS: We were able to improve speech recognition in quiet by optimizing the electrical dynamic range of experienced adult CI users, according to the prediction models built by de Graaff et al. (2020 ). There was no significant change in aided thresholds nor in speech recognition in noise. The findings of the present study suggest that improved performance for speech recognition in quiet in adult Cochlear CI users can be achieved by setting the dynamic range as close as possible to values between 50 and 60 CL when the volume level is at 10.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Ruido , Percepción del Habla , Humanos , Masculino , Persona de Mediana Edad , Femenino , Anciano , Adulto , Sordera/rehabilitación , Umbral Auditivo , Ajuste de Prótesis
13.
Eye Contact Lens ; 50(7): 297-304, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38695745

RESUMEN

OBJECTIVES: To explore the potential of artificial intelligence (AI) to assist prescription determination for orthokeratology (OK) lenses. METHODS: Artificial intelligence algorithm development followed by a real-world trial. A total of 11,502 OK lenses fitting records collected from seven clinical environments covering major brands. Records were randomly divided in a three-way data split. Cross-validation was used to identify the most accurate algorithm, followed by an evaluation using an independent test data set. An online AI-assisted system was implemented and assessed in a real-world trial involving four junior and three senior clinicians. RESULTS: The primary outcome measure was the algorithm's accuracy (ACC). The ACC of the best performance of algorithms to predict the targeted reduction amplitude, lens diameter, and alignment curve of the prescription was 0.80, 0.82, and 0.83, respectively. With the assistance of the AI system, the number of trials required to determine the final prescription significantly decreased for six of the seven participating clinicians (all P <0.01). This reduction was more significant among junior clinicians compared with consultants (0.76±0.60 vs. 0.32±0.60, P <0.001). Junior clinicians achieved clinical outcomes comparable to their seniors, as 93.96% (140/149) and 94.44% (119/126), respectively, of the eyes fitted achieved unaided visual acuity no worse than 0.8 ( P =0.864). CONCLUSIONS: AI can improve prescription efficiency and reduce discrepancies in clinical outcomes among clinicians with differing levels of experience. Embedment of AI in practice should ultimately help lessen the medical burden and improve service quality for myopia boom emerging worldwide.


Asunto(s)
Algoritmos , Inteligencia Artificial , Miopía , Procedimientos de Ortoqueratología , Prescripciones , Humanos , Procedimientos de Ortoqueratología/métodos , Miopía/terapia , Miopía/fisiopatología , Femenino , Masculino , Lentes de Contacto , Niño , Ajuste de Prótesis/métodos , Adolescente , Agudeza Visual/fisiología
14.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742501

RESUMEN

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Asunto(s)
Lentes de Contacto , Queratocono , Esclerótica , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Femenino , Masculino , Adulto , Esclerótica/cirugía , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Resultado del Tratamiento , Topografía de la Córnea , Prótesis e Implantes , Adulto Joven , Ajuste de Prótesis/métodos , Adolescente , Sustancia Propia/cirugía
15.
Ophthalmic Physiol Opt ; 44(5): 867-875, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38699941

RESUMEN

PURPOSE: The fit and optical performance of a scleral lens is affected by the alignment of the landing zone with the underlying ocular surface. The aim of this research was to quantify the effect of landing zone toricity upon scleral lens fitting characteristics (rotation and decentration) and optics (lens flexure) during short-term wear. METHODS: Scleral lenses with nominal landing zone toricities of 0, 100, 150 and 200 µm were worn in a randomised order by 10 young healthy participants (mean [SD] 24 [7] years) for 30 min, with other lens parameters held constant. Scleral toricity was quantified using a corneo-scleral profilometer, and lens flexure, rotation, and decentration were quantified using over-topography during lens wear. Repeated measures analyses were conducted as a function of landing zone toricity and residual scleral toricity (the difference between scleral and lens toricity) for eyes with 'low' magnitude scleral toricity (mean: 96 µm) and 'high' magnitude scleral toricity (mean: 319 µm). RESULTS: Toric landing zones significantly reduced lens flexure (by 0.37 [0.21] D, p < 0.05) and lens rotation (by 20 [24]°, p < 0.05) compared with a spherical landing zone. Horizontal and vertical lens decentration did not vary significantly with landing zone toricity. These trends for flexure, rotation, and decentration were also observed for eyes with 'low' and 'high' magnitude scleral toricity as a function of residual scleral toricity. CONCLUSION: Landing zones with 100-200 µm toricity significantly reduced lens flexure (by ~62%) and rotation (by ~77%) but not horizontal or vertical lens decentration, compared with a spherical landing zone, when controlling for other confounding variables. The incorporation of a toric landing zone, even for eyes with lower magnitude scleral toricity (~100 µm), may be beneficial, particularly for front surface optical designs.


Asunto(s)
Lentes de Contacto , Refracción Ocular , Esclerótica , Humanos , Masculino , Adulto Joven , Adulto , Femenino , Refracción Ocular/fisiología , Ajuste de Prótesis , Óptica y Fotónica , Topografía de la Córnea , Agudeza Visual/fisiología
16.
Sci Rep ; 14(1): 11168, 2024 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-38750086

RESUMEN

It is essential that people with limb amputation maintain proper prosthetic socket fit to prevent injury. Monitoring and adjusting socket fit, for example by removing the prosthesis to add prosthetic socks, is burdensome and can adversely affect users' function and quality-of-life. This study presents results from take-home testing of a motor-driven adaptive socket that automatically adjusted socket size during walking. A socket fit metric was calculated from inductive sensor measurements of the distance between the elastomeric liner surrounding the residual limb and the socket's inner surface. A proportional-integral controller was implemented to adjust socket size. When tested on 12 participants with transtibial amputation, the controller was active a mean of 68% of the walking time. In general, participants who walked more than 20 min/day demonstrated greater activity, less doff time, and fewer manual socket size adjustments for the adaptive socket compared with a locked non-adjustable socket and a motor-driven socket that participants adjusted with a smartphone application. Nine of 12 participants reported that they would use a motor-driven adjustable socket if it were available as it would limit their socket fit issues. The size and weight of the adaptive socket were considered the most important variables to improve.


Asunto(s)
Amputación Quirúrgica , Miembros Artificiales , Diseño de Prótesis , Tibia , Caminata , Humanos , Masculino , Femenino , Persona de Mediana Edad , Tibia/cirugía , Adulto , Ajuste de Prótesis/métodos , Anciano , Amputados/rehabilitación , Calidad de Vida
17.
J Oral Rehabil ; 51(7): 1123-1134, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38491740

RESUMEN

OBJECTIVE: Previous studies focused on the benefits of adequate prosthodontic treatment, while few studies have investigated the prosthodontic-related risks to health. As a modifiable oral health indicator, the association of ill-fitting prosthesis (IFP) with hypertension has not been fully explored. METHODS: This cross-sectional study involved 158,659 adults in Beijing (2009-2017) receiving intra-oral examinations and blood pressure measurements. Logistic regression models were applied to assess the association of IFP with the prevalence of hypertension, systolic blood pressure (SBP) ≧ 140 mmHg and diastolic blood pressure (DBP) ≧ 90 mmHg, as well as subgroup analyses by different fixed IFP subgroups (according to involved teeth number) and removable IFP subgroup. We further investigated effect modifications among stratified populations. RESULTS: 158,659 individuals were included for analysis, 346 (26.86%) in IFP group and 27,380 (17.40%) in non-IFP group (p < 0.001) were hypertensive. After adjustment of sex, age, obesity, dyslipidaemia, diabetes, hsCRP, family history of CVD, self-reported smoking, self-reported drinking and WC, ORs of hypertension, SBP ≧ 140 mmHg and DBP ≧ 90 mmHg were 1.330 (95% CI: 1.162-1.522), 1.277 (95% CI: 1.098-1.486) and 1.376 (95% CI: 1.186-1.596), respectively (p < 0.05). Furthermore, after full adjustment, the number of involved teeth showed a significant incremental trend with hypertension risk in the population with and without IFP (p for trend <0.001). The IFP-blood pressure associations were more pronounced in females, 18-60 years, non-obese and diabetic participants. CONCLUSION: As a modifiable oral indicator, IFP was significantly associated with a higher risk of hypertension.


Asunto(s)
Hipertensión , Humanos , Hipertensión/epidemiología , Femenino , Estudios Transversales , Masculino , Persona de Mediana Edad , Adulto , Factores de Riesgo , Prevalencia , Anciano , Ajuste de Prótesis , Presión Sanguínea/fisiología , Beijing/epidemiología , Prótesis Dental/efectos adversos
18.
Cont Lens Anterior Eye ; 47(3): 102136, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38503665

RESUMEN

PURPOSE: To investigate the effects of modifications in back optical zone diameter (BOZD), reverse curve width (RCW), and compression factor (CF) on refractive error changes and axial elongation in myopic children undergoing orthokeratology (ortho-k) over a 12-month period. METHOD: In this retrospective study, data from 126 myopic children undergoing ortho-k fitting were analyzed. Subjects were categorized into four distinct groups based on lens design parameters: Group A (BOZD 6.0 mm, RCW 0.6 mm, CF 0.75 D); Group B (BOZD 6.0 mm, RCW 0.6 mm, CF 1.25 D); Group C (BOZD 5.4 mm, RCW 0.9 mm, CF 1.25 D); and Group D (BOZD 5.0 mm, RCW 1.1 mm, CF 1.25 D). The study evaluated uncorrected visual acuity (UCVA), corneal topography, and axial length (AL) at intervals, using Linear Mixed Models (LMMs) for time-based changes, and ANOVA or Kruskal-Wallis tests for group differences in AL elongation. A multivariable regression analysis identified factors independently associated with AL elongation. RESULTS: Within the first day and week, all four groups displayed significant improvements in UCVA and alterations in corneal curvature, which subsequently stabilized. Although UCVA variations between groups were subtle, Group D had less corneal curvature change than Groups A and B initially and exhibited significantly less AL elongation after one year. No significant difference in corneal curvature change or AL elongation was observed between Group C and the other groups. Multiple regression analysis indicated that older baseline age, greater baseline spherical equivalent refractive error, and smaller BOZD were associated with less AL elongation. CONCLUSION: The study reveals a positive correlation between BOZD and axial length growth over the 12-month period. A pure 0.5 D CF increment demonstrates a nonsignificant impact. This study provides new ideas into optimizing the parameters of ortho-k lenses.


Asunto(s)
Longitud Axial del Ojo , Lentes de Contacto , Topografía de la Córnea , Miopía , Procedimientos de Ortoqueratología , Refracción Ocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Miopía/fisiopatología , Miopía/terapia , Femenino , Masculino , Niño , Agudeza Visual/fisiología , Longitud Axial del Ojo/fisiopatología , Refracción Ocular/fisiología , Adolescente , Ajuste de Prótesis , Córnea/fisiopatología
19.
Ann Thorac Surg ; 117(6): 1164-1171, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38316377

RESUMEN

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Humanos , Femenino , Masculino , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Diseño de Prótesis , Anciano de 80 o más Años , Resultado del Tratamiento , Ajuste de Prótesis
20.
Int Urol Nephrol ; 56(7): 2147-2156, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38315282

RESUMEN

PURPOSE: Patients with post prostatectomy incontinence (PPI) seem to have different needs. Therefore, device post-operative readjustability may be a beneficial feature in PPI management, even though it lacks study support. The purpose of this study is to describe our surgical technique for male sling (MS) implantation, assess outcomes, and the impact of readjustability. METHODS: We performed a retrospective analysis of 89 consecutive patients who underwent PPI correction with MS Argus-T™ (Promedon, Córdoba, Argentina) from 2009 to 2021. The median follow-up was 48 months (12-120). Data were collected in a dedicated database. Perioperative variables were assessed. A descriptive statistical analysis was performed. Clinical and urodynamic variables were correlated with the need for readjustments and success. RESULTS: In this cohort, objective success was achieved in 80.5% of the patients (65.9% cured and 14.6% improved). A total of 85.4% of the patients met the criteria for subjective success (74.4% cured and 11% improved). For the subgroup of patients who received previous treatment for urethral stricture (US), 79% achieved objective success (63.2% cured, 15.8% improved), and 84.2% achieved subjective success (78.9% cured, 5.3% improved). For the subgroup of patients who received previous radiotherapy (RT) before sling surgery, 68.7% achieved objective success (37.5% cured, 31.2% improved), and 75% achieved subjective success (37.5% cured, 37.5% improved). Procedures for device readjustment were necessary for 27.7% of patients in the total study population. RT and previous US treatment were predictive factors for the need of readjustment, with rates of 66.7% and 61.1% (OR: 8.46; CI: 2.46-29.00; p = 0.001/OR: 6.41; CI: 2.05-20.03; p = 0.001, respectively). CONCLUSIONS: MS adjustability improved success rates, especially among irradiated patients and those with previous US. RT was an adverse predictor of total continence status even after readjustments.


Asunto(s)
Prostatectomía , Cabestrillo Suburetral , Humanos , Masculino , Estudios Retrospectivos , Anciano , Prostatectomía/métodos , Persona de Mediana Edad , Complicaciones Posoperatorias , Procedimientos Quirúrgicos Urológicos Masculinos/métodos , Diseño de Prótesis , Incontinencia Urinaria/cirugía , Ajuste de Prótesis , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...