Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
BMJ Open Qual ; 12(3)2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37474134

RESUMEN

BACKGROUND: Physiological monitoring systems, like Masimo, used during inpatient hospitalisation, offer a non-invasive approach to capture critical vital signs data. These systems trigger alarms when measurements deviate from preset parameters. However, often non-urgent or potentially false alarms contribute to 'alarm fatigue,' a form of sensory overload that can have adverse effects on both patients and healthcare staff. The Joint Commission, in 2021, announced a target to mitigate alarm fatigue-related fatalities through improved alarm management. Yet, no established guidelines are presently available. This study aims to address alarm fatigue at the Mayo Clinic to safeguard patient safety, curb staff burnout and improve the sensitivity of oxygen saturation monitoring to promptly detect emergencies. METHODS: A quality improvement project was conducted to combat minimise the false alarm burden, with data collected 2 months prior to intervention commencement. The project's goal was to decrease the total alarm value by 20% from 55%-85% to 35%-75% within 2 months, leveraging quality improvement methodologies. INTERVENTIONS: February to April 2021, we implemented a two-pronged intervention: (1) instituting a protocol to evaluate patients' continuous monitoring needs and discontinuing it when appropriate, and (2) introducing educational signage for patients and Mayo Clinic staff on monitoring best practices. RESULTS: Baseline averages of red alarms (158.6), manual snoozes (37.8) and self-resolves (120.7); the first postintervention phase showed reductions in red alarms (125.5), manual snoozes (17.8) and self-resolves (107.8). Second postintervention phase recorded 138 red alarms, 13 manual snoozes and 125 self-resolves. Baseline comparison demonstrated an average of 16.92% reduction of alarms among both interventions (p value: 0.25). CONCLUSION: Simple interventions like education and communication techniques proved instrumental in lessening the alarm burden for patients and staff. The findings underscore the practical use and efficacy of these methods in any healthcare setting, thus contributing to mitigating the prevalent issue of alarm fatigue.


Asunto(s)
Agotamiento Profesional , Alarmas Clínicas , Humanos , Seguridad del Paciente , Alarmas Clínicas/efectos adversos , Monitoreo Fisiológico/métodos , Instituciones de Salud
2.
J Clin Nurs ; 32(13-14): 3469-3481, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35712789

RESUMEN

AIMS AND OBJECTIVES: This study examined the occurrence rate of specific types of premature ventricular complex (PVC) alarms and whether patient demographic and/or clinical characteristics were associated with PVC occurrences. BACKGROUND: Because PVCs can signal myocardial irritability, in-hospital electrocardiographic (ECG) monitors are typically configured to alert nurses when they occur. However, PVC alarms are common and can contribute to alarm fatigue. A better understanding of occurrences of PVCs could help guide alarm management strategies. DESIGN: A secondary quantitative analysis from an alarm study. METHODS: The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) checklist was followed. Seven PVC alarm types (vendor-specific) were described, and included isolated, couplet, bigeminy, trigeminy, run PVC (i.e. VT >2), R-on-T and PVCs/min. Negative binomial and hurdle regression analyses were computed to examine the association of patient demographic and clinical characteristics with each PVC type. RESULTS: A total of 797,072 PVC alarms (45,271 monitoring hours) occurred in 446 patients, including six who had disproportionately high PVC alarm counts (40% of the total alarms). Isolated PVCs were the most frequent type (81.13%) while R-on-T were the least common (0.29%). Significant predictors associated with higher alarms rates: older age (isolated PVCs, bigeminy and couplets); male sex and presence of PVCs on the 12-lead ECG (isolated PVCs). Hyperkalaemia at ICU admission was associated with a lower R-on-T type PVCs. CONCLUSIONS: Only a few distinct demographic and clinical characteristics were associated with the occurrence rate of PVC alarms. Further research is warranted to examine whether PVCs were associated with adverse outcomes, which could guide alarm management strategies to reduce unnecessary PVC alarms. RELEVANCE TO CLINICAL PRACTICE: Targeted alarm strategies, such as turning off certain PVC-type alarms and evaluating alarm trends in the first 24 h of admission in select patients, might add to the current practice of alarm management.


Asunto(s)
Alarmas Clínicas , Complejos Prematuros Ventriculares , Humanos , Masculino , Electrocardiografía , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/epidemiología , Complejos Prematuros Ventriculares/complicaciones , Unidades de Cuidados Intensivos , Hospitales , Monitoreo Fisiológico , Alarmas Clínicas/efectos adversos
4.
Pediatr Cardiol ; 42(1): 215-218, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33247766

RESUMEN

An infant with congenital heart block and hemodynamically significant bradycardia underwent therapeutic temporary pacing wires placement. Post-operatively, frequent "asystole" alarms were observed on telemetry causing distress to both the family and the nursing staff. Investigation of these alarms showed that pacemaker malfunction led to monitor pseudo-malfunction. The alarms were alleviated with mindful setting of the pacemaker and telemetry monitor parameters. This case highlights the challenges of pacemaker placement and monitoring of very small infants in the intensive care setting. Awareness of these challenges would help in troubleshooting pacemaker and telemetry monitor issues.


Asunto(s)
Bradicardia/cirugía , Marcapaso Artificial/efectos adversos , Alarmas Clínicas/efectos adversos , Reacciones Falso Positivas , Femenino , Paro Cardíaco/diagnóstico , Humanos , Recién Nacido , Recien Nacido Prematuro , Telemetría
5.
Intensive Crit Care Nurs ; 59: 102845, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32238311

RESUMEN

OBJECTIVE: The present study aimed to determine the types of monitor alarms and nurses' responses to them in an adult intensive care unit. DESIGN AND METHODS: This was an observational descriptive research study conducted in the adult intensive care unit of a university hospital in the Mediterranean region of Turkey. The nonparticipant observation method was used. Data were collected by two observers using a semi-structured observation form developed according to literature. RESULTS: Between August 2016 and January 2017, 13 registered nurses were observed for 328 hours. There were 1781 alarms, which included alarms for blood pressure (37.6%), respiration and oxygen saturation (35.3%) and heart rate and arrhythmia (27.1%). Nurses responded to approximately half (46.9%) of the alarms that required a response. Responses to alarms included silencing them, responding to the patient's clinical condition and solving contact and transmission problems. CONCLUSION: In the present study, according to response requirement, the division of the alarms was different. The number of alarms that do not reflect the clinical status of the patient was high. It was found that as the false alarm rate increased, the response rate of nurses to these alarms decreased.


Asunto(s)
Alarmas Clínicas/efectos adversos , Enfermeras y Enfermeros/psicología , Adulto , Distribución de Chi-Cuadrado , Alarmas Clínicas/normas , Alarmas Clínicas/estadística & datos numéricos , Femenino , Humanos , Unidades de Cuidados Intensivos/organización & administración , Unidades de Cuidados Intensivos/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Enfermeras y Enfermeros/estadística & datos numéricos , Estadísticas no Paramétricas , Encuestas y Cuestionarios , Turquía
6.
J Nurs Care Qual ; 35(2): 115-122, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31513051

RESUMEN

BACKGROUND: Nonactionable alarms comprise over 70% of alarms and contribute a threat to patient safety. Few studies have reported approaches to translate and sustain these interventions in clinical settings. PURPOSE: This study tested whether an interprofessional team-based approach can translate and implement effective alarm reduction interventions in the adult intensive care unit. METHODS: The study was a prospective, cohort, pre- and postdesign with repeated measures at baseline (preintervention) and post-phase I and II intervention periods. The settings for the most prevalent nonactionable arrhythmia and bedside parameter alarms were adjusted during phases I and II, respectively. RESULTS: The number of total alarms was reduced by 40% over a 14-day period after both intervention phases were implemented. The most prevalent nonactionable parameter alarms decreased by 47% and arrhythmia alarms decreased by 46%. CONCLUSIONS: It is feasible to translate and sustain system-level alarm management interventions addressing alarm fatigue using an interprofessional team-based approach.


Asunto(s)
Alarmas Clínicas , Unidades de Cuidados Intensivos/organización & administración , Monitoreo Fisiológico/enfermería , Grupo de Atención al Paciente , Seguridad del Paciente , Adulto , Alarmas Clínicas/efectos adversos , Alarmas Clínicas/estadística & datos numéricos , Enfermería de Cuidados Críticos , Femenino , Humanos , Monitoreo Fisiológico/instrumentación , Estudios Prospectivos
7.
Respir Care ; 64(10): 1308-1313, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31213570

RESUMEN

Mechanical ventilation alarms and alerts, both audible and visual, provide the clinician with vital information about the patient's physiologic condition and the status of the machine's function. Not all alarms generated by the mechanical ventilator provide actionable information. Over time, clinicians can become desensitized to audible alarms due to alarm fatigue and may potentially ignore an actionable situation that results in patient harm. Alarm fatigue has been recognized by multiple agencies as a major patient-safety issue. To date, mechanical ventilator alarm settings do not have standardized nomenclature. The aim of this review was to examine and report on the literature that pertains to mechanical ventilation alarms and alarm fatigue and to propose recommendations for future research that may lead to safer mechanical ventilation alarm practices.


Asunto(s)
Fatiga de Alerta del Personal de Salud , Alarmas Clínicas , Respiración Artificial , Alarmas Clínicas/efectos adversos , Humanos , Ruido en el Ambiente de Trabajo/efectos adversos , Filtrado Sensorial
8.
Am J Crit Care ; 28(3): 222-229, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31043402

RESUMEN

BACKGROUND: Excessive electrocardiographic alarms contribute to "alarm fatigue," which can lead to patient harm. In a prior study, one-third of audible electrocardiographic alarms were for accelerated ventricular rhythm (AVR), and most of these alarms were false. It is uncertain whether true AVR alarms are clinically relevant. OBJECTIVES: To determine from bedside electrocardiographic monitoring data (1) how often true AVR alarms are acknowledged by clinicians, (2) whether such alarms are actionable, and (3) whether such alarms are associated with adverse outcomes ("code blue," death). METHODS: Secondary analysis using data from a study conducted in an academic medical center involving 5 adult intensive care units with 77 beds. Electronic health records of 23 patients with 223 true alarms for AVR were examined. RESULTS: The mean age of the patients was 62.9 years, and 61% were white and male. All 223 of the true alarms were configured at the warning level (ie, 2 continuous beeps), and 215 (96.4%) lasted less than 30 seconds. Only 1 alarm was acknowledged in the electronic health record. None of the alarms were clinically actionable or led to a code blue or death. CONCLUSIONS: True AVR alarms may contribute to alarm fatigue. Hospitals should reevaluate the need for close monitoring of AVR and consider configuring this alarm to an inaudible message setting to reduce the risk of patient harm due to alarm fatigue. Prospective studies involving larger patient samples and varied monitors are warranted.


Asunto(s)
Ritmo Idioventricular Acelerado/diagnóstico , Alarmas Clínicas/efectos adversos , Alarmas Clínicas/estadística & datos numéricos , Electrocardiografía/instrumentación , Ritmo Idioventricular Acelerado/mortalidad , Adolescente , Adulto , Anciano , Resultados de Cuidados Críticos , Falla de Equipo/estadística & datos numéricos , Reacciones Falso Positivas , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/instrumentación , Seguridad del Paciente , Estudios Retrospectivos , Adulto Joven
9.
Hosp Pediatr ; 9(6): 423-428, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31043435

RESUMEN

OBJECTIVES: Continuous physiologic monitors (CPMs) generate frequent alarms and are used for up to 50% of children who are hospitalized outside of the ICU. Our objective was to assess factors that influence the decision to use CPMs. METHODS: In this qualitative study, we used group-level assessment, a structured method designed to engage diverse stakeholder groups. We recruited clinicians and other staff who work on a 48-bed hospital medicine unit at a freestanding children's hospital. We developed a list of open-ended prompts used to address CPM use on inpatient units. Demographic data were collected from each participant. We conducted 6 sessions to permit maximum participation among all groups, and themes from all sessions were merged and distilled. RESULTS: Participants (n = 78) included nurses (37%), attending physicians (17%), pediatric residents (32%), and unit staff (eg, unit coordinator; 14%). Participants identified several themes. First, there are patient factors (eg, complexity and instability) for which CPMs are useful. Second, participants perceived that alarms have negative effects on families (eg, anxiety and sleep deprivation). Third, CPMs are often used as surrogates for clinical assessments. Fourth, CPM alarms cause anxiety and fatigue for frontline staff. Fifth, the decision to use CPMs should be, but is not often, a team decision. Sixth, and finally, there are issues related to the monitor system's setup that reduces its utility. CONCLUSIONS: Hospital medicine staff identified patient-, staff-, and system-level factors relevant to CPM use for children who were hospitalized. These data will inform the development of system-level interventions to improve CPM use and address high alarm rates.


Asunto(s)
Actitud del Personal de Salud , Alarmas Clínicas , Utilización de Equipos y Suministros/normas , Hospitales Pediátricos , Monitoreo Fisiológico , Alarmas Clínicas/efectos adversos , Alarmas Clínicas/normas , Femenino , Humanos , Masculino , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/psicología , Estrés Laboral/etiología , Estrés Laboral/psicología , Ohio , Investigación Cualitativa , Mejoramiento de la Calidad , Índice de Severidad de la Enfermedad , Privación de Sueño/etiología
10.
Nurs Forum ; 54(3): 369-375, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30838672

RESUMEN

BACKGROUND: Clinical alarms represent the top hazard listed in the "Top Ten Health Technology Hazards" report. Frequent false alarms can disrupt patient care and reduce trust in alarms. AIM: The aim of the present study was to investigate the perceptions and practices of critical and noncritical care nurses regarding clinical alarms. METHODOLOGY: This was a descriptive analytical study conducted from October 2016 to February 2017 at three hospitals on 197 nurses at Neyshabur University of Medical Sciences in Neyshabur, Northeastern Iran. Participants were selected through stratified random sampling. The perceptions were measured through the 2011 Health care Technology Foundation Clinical Alarms Survey. RESULTS: More than half of the nurses believed that frequent false alarms reduced trust in alarms, leading nurses to inappropriately disable alarms. The nurses ranked frequent false alarms as the most important issue in response to alarms. More than 60% of the nurses indicated that they needed more training on the use of bedside and central monitors. CONCLUSION: The result of this study suggested that frequent false alarms, as the most important issue related to alarms, should be taken into account by hospital administrators and researchers to decrease alarm fatigue and improve alarm system safety. More specialized clinical policies and procedures for alarm management should also be considered.


Asunto(s)
Alarmas Clínicas/normas , Enfermeras y Enfermeros/psicología , Proceso de Enfermería/tendencias , Percepción , Adulto , Actitud del Personal de Salud , Alarmas Clínicas/efectos adversos , Alarmas Clínicas/tendencias , Femenino , Humanos , Irán , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/enfermería , Monitoreo Fisiológico/normas , Enfermeras y Enfermeros/estadística & datos numéricos , Encuestas y Cuestionarios
11.
Rev Bras Enferm ; 71(6): 3035-3040, 2018.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-30517409

RESUMEN

OBJECTIVE: To measure the response time of health professionals before sound alarm activation and the implications for patient safety. METHOD: This is a quantitative and observational research conducted in an Adult Intensive Care Unit of a teaching hospital. Three researchers conducted non-participant observations for seven hours. Data collection occurred simultaneously in 20 beds during the morning shift. When listening the alarm activation, the researchers turned on the stopwatches and recorded the motive, the response time and the professional conduct. During collection, the unit had 90% of beds occupied and teams were complete. RESULT: We verified that from the 103 equipment activated, 66.03% of alarms fatigued. Nursing was the professional category that most provided care (31.06%) and the multi-parameter monitor was the device that alarmed the most (66.09%). CONCLUSION: Results corroborate the absence or delay of the response of teams, suggesting that relevant alarms might have been underestimated, compromising patient safety.


Asunto(s)
Fatiga Auditiva , Alarmas Clínicas/efectos adversos , Factores de Tiempo , Brasil , Alarmas Clínicas/tendencias , Humanos , Unidades de Cuidados Intensivos/organización & administración , Unidades de Cuidados Intensivos/estadística & datos numéricos , Tiempo de Internación/estadística & datos numéricos , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Seguridad del Paciente/normas , Seguridad del Paciente/estadística & datos numéricos
12.
Rev. bras. enferm ; 71(6): 3035-3040, Nov.-Dec. 2018. tab
Artículo en Inglés | LILACS, BDENF | ID: biblio-977617

RESUMEN

ABSTRACT Objective: To measure the response time of health professionals before sound alarm activation and the implications for patient safety. Method: This is a quantitative and observational research conducted in an Adult Intensive Care Unit of a teaching hospital. Three researchers conducted non-participant observations for seven hours. Data collection occurred simultaneously in 20 beds during the morning shift. When listening the alarm activation, the researchers turned on the stopwatches and recorded the motive, the response time and the professional conduct. During collection, the unit had 90% of beds occupied and teams were complete. Result: We verified that from the 103 equipment activated, 66.03% of alarms fatigued. Nursing was the professional category that most provided care (31.06%) and the multi-parameter monitor was the device that alarmed the most (66.09%). Conclusion: Results corroborate the absence or delay of the response of teams, suggesting that relevant alarms might have been underestimated, compromising patient safety.


RESUMEN Objetivo: Mensurar el tiempo-respuesta de los profesionales de salud delante del disparo de las alarmas sonoras, y las implicaciones para la seguridad del paciente. Método: Investigación cuantitativa, observacional, en una Unidad de Terapia Intensiva - Adulto de un hospital de enseñanza. Los tres investigadores han realizado observaciones no participativas durante 7 horas. La recogida de los datos ha ocurrido simultáneamente en 20 camillas en el período diurno. Al oír el disparo, los investigadores accionaban los cronómetros y registraban el motivo, el tiempo-respuesta y la conducta profesional. Durante la recogida, la unidad estaba con el 90% de las camillas ocupadas y los equipos estaban completados. Resultados: Certificamos que, de los 103 equipamientos que han sido disparados, el 66,03% de las alarmas han fatigado. La enfermería ha sido la categoría profesional que más ha atendido (el 31,06%), y el monitor multiparámetros ha alarmado (el 66,09%). Conclusión: Los resultados han corroborado la ausencia o el retardo de la respuesta del equipo, sugiriendo que las alarmas relevantes hayan sido menospreciadas, comprometiendo la seguridad de los pacientes.


RESUMO Objetivo: Mensurar o tempo-resposta dos profissionais de saúde diante ao disparo dos alarmes sonoros e as implicações para a segurança do paciente. Método: Pesquisa quantitativa, observacional, em uma Unidade de Terapia Intensiva Adulto de um Hospital de Ensino. Os três pesquisadores realizaram observações não participativas durante 7 horas. A coleta de dados ocorreu simultaneamente em 20 leitos no período diurno. Ao ouvir o disparo, os pesquisadores acionavam os cronômetros e registravam o motivo, o tempo-resposta e a conduta profissional. Durante a coleta a unidade estava com 90% dos leitos ocupados e as equipes estavam completas. Resultados: Verificamos que, dos 103 equipamentos disparados, 66,03% dos alarmes fatigaram. A enfermagem foi a categoria profissional que mais atendeu (31.06%), e o monitor multiparâmetros alarmou (66,09%). Conclusão: Os resultados corroboram a ausência ou retardo de resposta da equipe, sugerindo que alarmes relevantes tenham sido menosprezados, comprometendo a segurança dos pacientes.


Asunto(s)
Humanos , Fatiga Auditiva , Factores de Tiempo , Alarmas Clínicas/efectos adversos , Brasil , Alarmas Clínicas/tendencias , Seguridad del Paciente/normas , Seguridad del Paciente/estadística & datos numéricos , Unidades de Cuidados Intensivos/organización & administración , Unidades de Cuidados Intensivos/estadística & datos numéricos , Tiempo de Internación/estadística & datos numéricos , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos
14.
Crit Care Nurs Clin North Am ; 30(2): 179-190, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29724437

RESUMEN

In this focus group study, we identified issues associated with sensory overload from medical technology alarms/alerts for intensive care unit nurses. Participants indicated that alarms from cardiopulmonary monitors, ventilators, and intravenous pumps contributed the most to sensory overload and, yet, these alarms were also deemed the most helpful. Alerts/alarms from electronic health records and medication dispensing systems were rated low in contributing to sensory overload, as well as being the least helpful. Specific device/technology barriers, related to device alerts/alarms, are detailed. Future user-centered and integrated improvements in alarm systems associated with medical devices in the intensive care unit are needed.


Asunto(s)
Alarmas Clínicas/efectos adversos , Alarmas Clínicas/estadística & datos numéricos , Cuidados Críticos/métodos , Monitoreo Fisiológico/instrumentación , Adulto , Femenino , Grupos Focales , Humanos , Unidades de Cuidados Intensivos , Investigación Cualitativa
16.
J Hosp Med ; 13(6): 396-398, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29694462

RESUMEN

Alarm fatigue has been linked to patient morbidity and mortality in hospitals due to delayed or absent responses to monitor alarms. We sought to describe alarm rates at 5 freestanding children's hospitals during a single day and the types of alarms and proportions of patients monitored by using a point-prevalence, cross-sectional study design. We collected audible alarms on all inpatient units and calculated overall alarm rates and rates by alarm type per monitored patient per day. We found a total of 147,213 alarms during the study period, with 3-fold variation in alarm rates across hospitals among similar unit types. Across hospitals, onequarter of monitored beds were responsible for 71%, 61%, and 63% of alarms in medical-surgical, neonatal intensive care, and pediatric intensive care units, respectively. Future work focused on addressing nonactionable alarms in patients with the highest alarm counts may decrease alarm rates.


Asunto(s)
Alarmas Clínicas/estadística & datos numéricos , Hospitales Pediátricos , Monitoreo Fisiológico/estadística & datos numéricos , Niño , Alarmas Clínicas/efectos adversos , Estudios Transversales , Humanos , Unidades de Cuidado Intensivo Pediátrico/estadística & datos numéricos
17.
Crit Care Med ; 46(1): 130-137, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29112077

RESUMEN

OBJECTIVE: Alarm fatigue is a widely recognized safety and quality problem where exposure to high rates of clinical alarms results in desensitization leading to dismissal of or slowed response to alarms. Nonactionable alarms are thought to be especially problematic. Despite these concerns, the number of clinical alarm signals has been increasing as an everincreasing number of medical technologies are added to the clinical care environment. DATA SOURCES: PubMed, SCOPUS, Embase, and CINAHL. STUDY SELECTION: We performed a systematic review of the literature focused on clinical alarms. We asked a primary key question; "what interventions have been attempted and resulted in the success of reducing alarm fatigue?" and 3-secondary key questions; "what are the negative effects on patients/families; what are the balancing outcomes (unintended consequences of interventions); and what human factor approaches apply to making an effective alarm?" DATA EXTRACTION: Articles relevant to the Key Questions were selected through an iterative review process and relevant data was extracted using a standardized tool. DATA SYNTHESIS: We found 62 articles that had relevant and usable data for at least one key question. We found that no study used/developed a clear definition of "alarm fatigue." For our primary key question 1, the relevant studies focused on three main areas: quality improvement/bundled activities; intervention comparisons; and analysis of algorithm-based false and total alarm suppression. All sought to reduce the number of total alarms and/or false alarms to improve the positive predictive value. Most studies were successful to varying degrees. None measured alarm fatigue directly. CONCLUSIONS: There is no agreed upon valid metric(s) for alarm fatigue, and the current methods are mostly indirect. Assuming that reducing the number of alarms and/or improving positive predictive value can reduce alarm fatigue, there are promising avenues to address patient safety and quality problem. Further investment is warranted not only in interventions that may reduce alarm fatigue but also in defining how to best measure it.


Asunto(s)
Alarmas Clínicas/efectos adversos , Unidades de Cuidados Intensivos , Fatiga Mental/prevención & control , Algoritmos , Actitud del Personal de Salud , Percepción Auditiva , Enfermedad Crítica , Aprendizaje Discriminativo , Diseño de Equipo , Humanos , Fatiga Mental/etiología , Música , Higiene del Sueño
18.
Ann Cardiol Angeiol (Paris) ; 67(1): 58-60, 2018 Feb.
Artículo en Francés | MEDLINE | ID: mdl-28684011

RESUMEN

INTRODUCTION: More than 60,000 pacemakers are inserted every year in France. This number has been steadily increasing for a decade. Miscellaneous incidents can lead patients with pacemakers or their relatives to contact emergency services. Following the call to the SAMU-Center 15 of a asymptomatic 90-year-old woman reported that her pacemaker was making "beep-beep", we assessed the knowledge of physicians of the SAMU-Center 15 (call center) dispatching center on the existence of pacemaker sound alarms. METHODS: Forty-two physicians, emergency physicians and general practitioners, regularly participating in the medical dispatching of the SAMU-Center 15 in Seine-Seine-Denis were interviewed. We asked them how a patient with a pacemaker could be informed of a malfunction of it without being symptomatic. RESULTS: No physician interviewed mentioned an audible alarm. All of them confirmed their ignorance of its existence. One physician had already been asked for a similar reason and had referred the patient to the emergency department without knowing it was an alarm. CONCLUSION: Patients and physicians seem insufficiently aware of the existence of the existence of pacemakers' sound alarm. An effort must be made regarding the information on the existence of such an alarm and the way to managed it.


Asunto(s)
Alarmas Clínicas/efectos adversos , Servicios Médicos de Urgencia , Medicina General/normas , Conocimientos, Actitudes y Práctica en Salud , Unidades de Cuidados Intensivos/normas , Marcapaso Artificial/estadística & datos numéricos , Médicos/normas , Anciano de 80 o más Años , Urgencias Médicas/epidemiología , Femenino , Francia/epidemiología , Medicina General/estadística & datos numéricos , Humanos , Unidades de Cuidados Intensivos/estadística & datos numéricos , Marcapaso Artificial/efectos adversos , Médicos/estadística & datos numéricos , Encuestas y Cuestionarios
19.
Artículo en Alemán | MEDLINE | ID: mdl-28743153

RESUMEN

Due to growing technisation of intensive care the number of devices with integrated alarm systems is steadily increasing. However, most of the sounding alarms are false alarms causing high levels of frustration, aggression and inappropriate behaviour amongst the medical personnel. All this jeopardises patient care. The high number of alarms also disturb the patients interrupting their sleep and provokes anxiety, and also increases the already high noise level in intensive care units and the operating theatre alike. In the interest of the medical staff and our patients, we should reduce the high frequency of false alarms by using modern alarm algorithms techniques, lower both noise exposure and stress load with the help of modern individualized alarm systems and by increasing awareness on the dangers of alarm fatigue through training and by using individualized patient-related alarm limits. Despite economic challenges hospitals and intensive care units should optimize staffing, thereby lowering the risk to patients and improving employee satisfaction.


Asunto(s)
Alarmas Clínicas/efectos adversos , Algoritmos , Cuidados Críticos , Falla de Equipo , Humanos , Unidades de Cuidados Intensivos/organización & administración , Satisfacción en el Trabajo , Monitoreo Fisiológico/instrumentación
20.
Crit Care Med ; 45(9): 1481-1488, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28682835

RESUMEN

OBJECTIVE: To provide ICU clinicians with evidence-based guidance on tested interventions that reduce or prevent alert fatigue within clinical decision support systems. DESIGN: Systematic review of PubMed, Embase, SCOPUS, and CINAHL for relevant literature from 1966 to February 2017. PATIENTS: Focus on critically ill patients and included evaluations in other patient care settings, as well. INTERVENTIONS: Identified interventions designed to reduce or prevent alert fatigue within clinical decision support systems. MEASUREMENTS AND MAIN RESULTS: Study selection was based on one primary key question to identify effective interventions that attempted to reduce alert fatigue and three secondary key questions that covered the negative effects of alert fatigue, potential unintended consequences of efforts to reduce alert fatigue, and ideal alert quantity. Data were abstracted by two reviewers independently using a standardized abstraction tool. Surveys, meeting abstracts, "gray" literature, studies not available in English, and studies with non-original data were excluded. For the primary key question, articles were excluded if they did not provide a comparator as key question 1 was designed as a problem, intervention, comparison, and outcome question. We anticipated that reduction in alert fatigue, including the concept of desensitization may not be directly measured and thus considered interventions that reduced alert quantity as a surrogate marker for alert fatigue. Twenty-six articles met the inclusion criteria. CONCLUSION: Approaches for managing alert fatigue in the ICU are provided as a result of reviewing tested interventions that reduced alert quantity with the anticipated effect of reducing fatigue. Suggested alert management strategies include prioritizing alerts, developing sophisticated alerts, customizing commercially available alerts, and including end user opinion in alert selection. Alert fatigue itself is studied less frequently, as an outcome, and there is a need for more precise evaluation. Standardized metrics for alert fatigue is needed to advance the field. Suggestions for standardized metrics are provided in this document.


Asunto(s)
Alarmas Clínicas/efectos adversos , Enfermedad Crítica , Sistemas de Apoyo a Decisiones Clínicas/organización & administración , Unidades de Cuidados Intensivos/organización & administración , Fatiga Mental/etiología , Fatiga Mental/prevención & control , Hipersensibilidad a las Drogas/epidemiología , Interacciones Farmacológicas , Humanos , Guías de Práctica Clínica como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...