Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.579
Filtrar
1.
J Prosthet Dent ; 132(2): 464.e1-464.e8, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38796354

RESUMEN

STATEMENT OF PROBLEM: Excellent optical properties are essential for esthetic dental materials. However, the translucency and color masking ability of zirconia fabricated with nanoparticle jetting (NPJ), a type of printed zirconia, are unknown. PURPOSE: The purpose of this in vitro study was to evaluate the translucency and color masking ability of zirconia fabricated using NPJ. MATERIAL AND METHODS: A total of 90 specimens with thicknesses of 1.5, 1.0, and 0.5 mm were fabricated using high translucent milled zirconia (HT), low translucent milled zirconia (LT), and NPJ. CIELab values (L*, a*, and b*) of the specimens over 7 backgrounds, black, white, VitaB1, VitaA2, VitaA4, gold alloy (Au), and titanium (Ti), were obtained using a spectral radiometer. The relative translucency parameter (RTP) and color difference (∆E) of specimens over VitaB1, VitaA4, Au, and Ti were determined using VitaA2 as the control with the CIEDE2000 color difference equation. The normality of the data distribution was determined using the Shapiro-Wilk test. Differences among groups were analyzed using 2-way analysis of variance and the Student-Newman-Keuls (SNK) post hoc test (α=.05). The ∆E of specimens was analyzed according to perceptibility (∆E=0.8) and acceptability (∆E=1.8) thresholds using the 1 sample t test. The correlation between RTP and ∆E and RTP/∆E and thickness was examined using the Pearson correlation analysis. RESULTS: Statistically significant differences were observed in translucency and color masking ability among HT, LT, and NPJ (P<.05). The RTP value was the lowest for zirconia fabricated with NPJ (P<.001) and highest for HT (P<.001). Monolithic zirconia fabricated with NPJ had lower ∆E values than those of HT and LT for the same thickness and background (P<.05). A positive correlation was found in RTP and ∆E (P<.001). A negative correlation was observed in RTP and thickness (P<.001) and ∆E and thickness across a constant background (P<.001). CONCLUSIONS: Zirconia fabricated with NPJ was less translucent and had a greater color masking ability for discolored backgrounds than HT and LT.


Asunto(s)
Color , Materiales Dentales , Circonio , Circonio/química , Materiales Dentales/química , Nanopartículas/química , Ensayo de Materiales , Titanio/química , Humanos , Técnicas In Vitro , Propiedades de Superficie , Aleaciones de Oro/química , Diseño de Prótesis Dental
2.
Clin Oral Investig ; 28(5): 298, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702521

RESUMEN

OBJECTIVES: To assess the long-term clinical performance of ceramic in-/onlays (CIOs) and cast gold partial crowns (CGPCs) in posterior teeth in terms of success, survival, complications (biological, technical) and quality. MATERIAL AND METHODS: In a retrospective study, a total of 325 patients were recorded after up to 24.8 years (mean 13.9 ± 3.8 years) having (pre-)molars restored with CIO (Empress I, Ivoclar Vivadent, n = 161) and CGPC (Degunorm, DeguDent, n = 164) by supervised undergraduate students. A total of 296 restorations were assessed clinically and radiologically in healthy and endodontically treated teeth using modified United States Public Health Service (USPHS) criteria. Cumulative success and survival rates of the restorations were calculated using Kaplan-Meier estimates. Biological and technical complications were recorded. Status of oral health comprising caries risk and localized periodontitis were assessed. RESULTS: The cumulative success rates of CIOs were 92.1% and of CGPCs 84.2% after mean service times of 14.5 years. The annual failure rates of total service times were 0.5% in teeth restored with CIO (n = 155) and 0.7% in teeth restored with CGPC (n = 163). The cumulative survival rates of CIOs were 93.9% after a mean service time of 15.2 years and decreased to 91.7% after 23.5 years. The cumulative survival rates of CGPCs were 92.6% after a mean service time of 14.9 years and 91.8% after 23.5 years. Complications in CIOs (n = 149) were ceramic fracture (6.7%), secondary caries (4.7%), endodontic complication (2.7%) and tooth fracture (1.3%) compared to CGPCs (n = 147) with endodontic complication (8.8%), secondary caries (4.8%) and decementation (2.0%). Endodontically treated teeth restored with CIO or CGPC revealed significantly less often success compared with corresponding vital teeth (p = .02). CIOs and CGPCs revealed clinically and radiographically good and excellent qualities with 71.8% (107/149) and 68% (100/147) without any significant differences regarding type of restoration. CONCLUSIONS: Both CIOs and CGPCs achieved high survival rates up to 24.8 years when performed by supervised undergraduate students. The longevity of the restorations may benefit from the intraoral repair of accessible defects and, in case of pulp infection or necrosis, an adequate endodontic management. CLINICAL RELEVANCE: CIOs and CGPCs made by supervised undergraduate students are proper restoration types in posterior teeth in the long-term. An adequate preparation design, meticulous care in the inserting technique and constant biofilm removal due to proper oral hygiene combined with professional maintenance care are substantial. The clinical long-term performance was mostly limited by ceramic fractures in CIOs and endodontic complications in CGPCs.


Asunto(s)
Coronas , Fracaso de la Restauración Dental , Humanos , Estudios Retrospectivos , Femenino , Masculino , Adulto , Incrustaciones , Cerámica , Aleaciones de Oro , Caries Dental/terapia , Porcelana Dental/química , Persona de Mediana Edad , Diseño de Prótesis Dental , Diente no Vital , Resultado del Tratamiento
3.
J Vis Exp ; (205)2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38557764

RESUMEN

This protocol describes the synthesis of Au nanoparticle seeds and the subsequent formation of Au-Sn bimetallic nanoparticles. These nanoparticles have potential applications in catalysis, optoelectronics, imaging, and drug delivery. Previously, methods for producing alloy nanoparticles have been time-consuming, require complex reaction conditions, and can have inconsistent results. The outlined protocol first describes the synthesis of approximately 13 nm Au nanoparticle seeds using the Turkevich method. The protocol next describes the reduction of Sn and its incorporation into the Au seeds to generate Au-Sn alloy nanoparticles. The optical and structural characterization of these nanoparticles is described. Optically, prominent localized surface plasmon resonances (LSPRs) are apparent using UV-visible spectroscopy. Structurally, powder X-ray diffraction (XRD) reflects all particles to be less than 20 nm and shows patterns for Au, Sn, and multiple Au-Sn intermetallic phases. Spherical morphology and size distribution are obtained from transmission electron microscopy (TEM) imaging. TEM reveals that after Sn incorporation, the nanoparticles grow to approximately 15 nm in diameter.


Asunto(s)
Aleaciones de Oro , Nanopartículas del Metal , Plata/química , Oro/química , Estaño , Nanopartículas del Metal/química , Aleaciones/química
4.
Int J Prosthodont ; (3): 339-348, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38227831

RESUMEN

PURPOSE: To evaluate the stress distribution along a premolar's root dentin, its post, and its post-luting agent when materials with different elastic moduli are used to fabricate one-piece post-and-cores in two different designs. MATERIALS AND METHODS: Two 3D virtual models (for cylindrical and conical post designs) of a mandibular premolar restored with one-piece post-and-core restorations were obtained using a software. A total of eight post-and-core materials were tested: polyetheretherketone (PEEK), polyetherketoneketone (PEKK), glass fiber-reinforced polyetheretherketone (GFR-PEEK), carbon fiber-reinforced polyetheretherketone (CFR-PEEK), gold-palladium alloy (Au-Pd), titanium (Ti), zirconia (Zi), and chromium-nickel (Cr-Ni). Maximum principals stress (MPS) in the post, post-luting agent, and root dentin were determined. A load of 150 N was applied to the buccal cusp in the linguo-labial direction at an angle of 45 degrees oblique to the longitudinal axis of the crown. RESULTS: The highest MPS value in post structure was observed with Cr-Ni material for both post designs. Similarly, the highest MPS value in the post-luting agent was observed for Cr-Ni, the material with the highest elastic modulus. However, in the root dentin, the highest value was observed in PEEK, the material with the lowest elastic modulus. CONCLUSIONS: Post material and design influenced the stress concentration in the post, post-luting agent, and root dentin. The stress at the root dentin was slightly higher for polymeric materials. Cylindrical post design revealed lower stresses than conical post design at root dentin for all post-and-core materials tested.


Asunto(s)
Benzofenonas , Fibra de Carbono , Materiales Dentales , Dentina , Módulo de Elasticidad , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Técnica de Perno Muñón , Titanio , Circonio , Polímeros/química , Humanos , Polietilenglicoles/química , Cetonas/química , Materiales Dentales/química , Circonio/química , Fenómenos Biomecánicos , Titanio/química , Diente Premolar , Vidrio/química , Aleaciones de Cromo/química , Aleaciones de Oro/química , Diseño de Prótesis Dental , Carbono , Análisis del Estrés Dental , Paladio/química , Raíz del Diente , Aleaciones Dentales/química , Estrés Mecánico , Níquel/química
5.
Chem Pharm Bull (Tokyo) ; 72(1): 121-126, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38296514

RESUMEN

In clinical diagnosis, fluorescent particles are applied to detect analytes in biofluids, such as blood and saliva. However, current fluorescence detection methods have not been optimized to account for the overlapping autofluorescence peaks of biological substances. Gold and silver nanoclusters are known to the novel fluorescent materials and their emission wavelengths depend on cluster size. In this study, we developed fluorescent silica nanoparticles using gold-silver alloy nanoclusters and chitosan (CS) (NH2-SiO2@Au@CS@AuAg) by the layer-by-layer method. Under UV-light irradiation at 365 nm, the emission wavelength of NH2-SiO2@Au@CS@AuAg reached 750 nm in the near-IR region. Scanning electron microscopy images revealed that the shape of NH2-SiO2@Au@CS@AuAg was uniform and spherical. The fluorescence spectrum of horse blood obtained in the presence of NH2-SiO2@Au@CS@AuAg contained a specific fluorescence peak attributed to NH2-SiO2@Au@CS@AuAg, which was distinguishable from the autofluorescence peaks. These results showed that NH2-SiO2@Au@CS@AuAg has advantageous fluorescence properties for clinical diagnostic applications.


Asunto(s)
Aleaciones de Oro , Nanopartículas del Metal , Animales , Caballos , Plata , Dióxido de Silicio , Oro
6.
Int J Legal Med ; 138(2): 685-691, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37347275

RESUMEN

Access to better health care anticipates that more medical devices can be found alongside skeletal remains. Those employed in oral rehabilitation, with available brands or batch/series, can prove useful in the identification process. A previous study in the Colecção de Esqueletos Identificados Século XXI described macroscopically the dental prostheses. An unusual case of a dental device with chromatic alterations demonstrated to require a more detailed analysis. The individual, a 53-year-old male, exhibited, at both arches, a fixed tooth-supported rehabilitation, with gold colouring classified initially as a gold-palladium alloy. Simultaneously, a green pigmentation deposit was observable in bone and prosthesis. This investigation aimed to verify the elemental composition of the dental prosthesis alloy. Elemental analysis was performed by X-ray fluorescence in two regions (labial surface of the prosthetic crown and the root surface of the lower right lateral incisor). Both the spectra and the qualitative results found higher levels of copper and aluminium, followed by nickel, iron, zinc, and manganese. No gold or palladium was detected. The most probable assumption is that a copper-aluminium alloy was used, as its elemental concentration corresponds to those measured in similar devices. Dental prostheses of copper-aluminium alloys have been made popular since the 1980s, particularly in the USA, Japan, and Eastern Europe. Apart from the biographical information, it was also known that the individual's place of birth was an Eastern European country, which highlighted the usefulness of this type of information when dealing with missing people cases.


Asunto(s)
Prótesis Dental , Paladio , Masculino , Humanos , Persona de Mediana Edad , Rayos X , Portugal , Paladio/análisis , Cobre/análisis , Aluminio/análisis , Fluorescencia , Incisivo , Aleaciones de Oro/análisis
7.
Sci Total Environ ; 912: 169267, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38092205

RESUMEN

The Olympia oyster, Ostrea lurida, is the target of many restoration projects along estuaries on the North American Pacific coast, while the non-native Pacific oyster, Magallana gigas, dominates oyster aquaculture globally. Both species provide filtration functions that were investigated in three California bays using a whole-habitat, in situ approach, a laboratory particle selection experiment, and a regional physiological comparison. Measurements of chlorophyll α, temperature, salinity, and turbidity upstream and downstream, as well as point samples of seston total particulate matter and organic content to estimate habitat clearance rates (HCR, L hr-1 m-2) were collected. From February 2018 to June 2019, twenty-two trials were conducted across four sites. HCRs were highly variable within and among sites, ranging from site averages of -464 to 166 L hr-1 m-2, and not significantly different among sites, indicating field filtration performance of O. lurida habitat and M. gigas aquaculture is similar. Using a random forest regression, site was the most important predictor of HCR, with a variable importance score of 25.7 % (SD = 4.6 %). O. lurida and M. gigas had significantly different particle size selection preferences, likely affecting the quality of their filtration. This study's findings suggest that restoring O. lurida habitat may provide similar filtration benefits as M. gigas aquaculture, but the unique hydrodynamics and food quality of individual bays, as well as regional differences in filter feeder communities, must be considered in managing oyster habitat for filtration functions.


Asunto(s)
Crassostrea , Aleaciones de Oro , Ostrea , Animales , Estuarios , Tamaño de la Partícula , Ecosistema , América del Norte
8.
Shanghai Kou Qiang Yi Xue ; 32(4): 428-431, 2023 Aug.
Artículo en Chino | MEDLINE | ID: mdl-38044740

RESUMEN

PURPOSE: To investigate the effects of metal materials for oral fixation and restoration on magnetic resonance imaging artifacts and the health of tissues around dental implants. METHODS: A total of 153 patients undergoing fixed oral restoration were selected from May 2018 to June 2020. They were divided according to the random number table method into group A (cobalt-chromium alloy, n=31), group B (nickel-chromium alloy, n=32), group C (titanium alloy, n=28), group D (pure titanium, n=29) and group E (gold alloy, n=33). The largest area of metal crown artifacts and the number of layers of the 5 groups were compared. The probing depth(PD), modified plaque index(mPLI), modified sulcus bleeding index(mSBI) and papilla index(PI) 6 months after restoration were evaluated.The data were statistically analyzed with SPSS 22.0 software package. RESULTS: One-way ANOVA showed that the largest area of metal crown artifacts and the number of layers involved in the 5 groups had significant differences(P<0.05). Pairwise comparison showed that the largest area of metal crown artifacts, and the number of involved layers in group E were significantly lower than those in groups A, B, C, and D(P<0.05). One-way ANOVA showed that there was no significant difference in PD, mPLI, mSBI and PI among 5 groups (P>0.05). Pairwise comparison showed that there was no significant difference in PD, mPLI, mSBI and PI between group A and group B,C,D and E (P>0.05). CONCLUSIONS: The artifacts produced by metal materials for oral fixation and restoration are closely related to the types of metal materials. Among them, cobalt-chromium alloys produce the largest artifacts, and gold alloys produce the smallest artifacts. The use of metal materials for oral fixation and restoration will not affect the health of tissues around dental implants.


Asunto(s)
Implantes Dentales , Titanio , Humanos , Titanio/efectos adversos , Implantes Dentales/efectos adversos , Artefactos , Coronas , Aleaciones de Oro , Imagen por Resonancia Magnética/métodos
9.
Anal Chem ; 95(47): 17318-17327, 2023 11 28.
Artículo en Inglés | MEDLINE | ID: mdl-37967331

RESUMEN

Although the competitive lateral flow immunoassay (CLFIA) using gold nanoparticles (AuNPs) as labels has been widely adopted for the rapid detection of small molecules, its sensitivity is often constrained by the insufficient colorimetric signal produced by conventional AuNPs labels. Herein, we introduce a new type of intensified colorimetric label, denoted as SAAS, which is engineered by integrating gold-silver alloy nanoparticles (Au-Ag NPs) within a dendritic silica scaffold. These pitaya-type silica nanohybrids combine the advantages of the amplified molar extinction coefficient of alloy units with the signal collective effect of numerous Au-Ag NPs in a singular label. The SAAS-based CLFIA strips not only achieve qualitative screening of aflatoxin B1 (AFB1) at an extraordinarily low concentration of 0.2 ng/mL by the naked eye but also enable precise AFB1 quantification through a smartphone, with a remarkable limit of detection of 0.00314 ng/mL. Moreover, by leveraging SAAS as a quencher, we have delved into transforming the conventional signal-off mode of competitive immunoassay into a signal-on configuration. This innovation led to the development of a fluorescent LFIA that augments interpretative precision and sensitivity. Our study demonstrates the substantial potential of the proposed nanohybrid labels in enhancing the sensitivity of CLFIA for detecting small molecules.


Asunto(s)
Nanopartículas del Metal , Dióxido de Silicio , Oro , Inmunoensayo , Plata , Aleaciones de Oro , Aleaciones , Límite de Detección
10.
Adv Healthc Mater ; 12(30): e2302084, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37661312

RESUMEN

The bactericidal effects of silver nanoparticles (Ag NPs) against infectious strains of multiresistant bacteria is a well-studied phenomenon, highly relevant for many researchers and clinicians battling bacterial infections. However, little is known about the uptake of the Ag NPs into the bacteria, the related uptake mechanisms, and how they are connected to antimicrobial activity. Even less information is available on AgAu alloy NPs uptake. In this work, the interactions between colloidal silver-gold alloy nanoparticles (AgAu NPs) and Staphylococcus aureus (S. aureus) using advanced electron microscopy methods are studied. The localization of the nanoparticles is monitored on the membrane and inside the bacterial cells and the elemental compositions of intra- and extracellular nanoparticle species. The findings reveal the formation of pure silver nanoparticles with diameters smaller than 10 nm inside the bacteria, even though those particles are not present in the original colloid. This finding is explained by a local RElease PEnetration Reduction (REPER) mechanism of silver cations emitted from the AgAu nanoparticles, emphasized by the localization of the AgAu nanoparticles on the bacterial membrane by aptamer targeting ligands. These findings can deepen the understanding of the antimicrobial effect of nanosilver, where the microbes are defusing the attacking silver ions via their reduction, and aid in the development of suitable therapeutic approaches.


Asunto(s)
Aleaciones de Oro , Nanopartículas del Metal , Aleaciones de Oro/farmacología , Plata/farmacología , Staphylococcus aureus , Aleaciones/farmacología , Oro/farmacología , Bacterias , Antibacterianos/farmacología , Pruebas de Sensibilidad Microbiana
11.
Dent Mater J ; 42(5): 732-738, 2023 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-37612059

RESUMEN

The aim of this study was to investigate the effect of repeated casting and heat treatment on the corrosion resistance of a commercial Ag-Pd-Cu-Au alloy as evaluated by electrochemical techniques. After repeated casting, the fifth cast of the Ag-Pd-Cu-Au alloy exhibited dramatic degradation of properties, although upon heat treatment, this corrosion resistance did improve. Despite the improvement by heat treatment, after five castings, this alloy may not have satisfactory hardness for clinical use. These results of this study demonstrate that, up to the fourth cast and heat treatment, the Ag-Pd-Cu-Au alloy has acceptable corrosion resistance and hardness.


Asunto(s)
Corrosión , Aleaciones Dentales , Técnica de Colado Dental , Calor , Ensayo de Materiales , Aleaciones/química , Cobre/química , Aleaciones Dentales/química , Aleaciones de Oro/química , Ensayo de Materiales/métodos , Paladio/química , Plata/química , Técnica de Colado Dental/efectos adversos , Técnica de Colado Dental/normas
12.
STAR Protoc ; 4(3): 102410, 2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37393611

RESUMEN

Plasmonic nanoparticles and nanocrystalline materials have broad applicability in catalysis, optoelectronics, sensing, and sustainability. Below, we detail a robust protocol for the synthesis of bimetallic Au-Sn nanoparticles in mild, aqueous conditions. This protocol describes the steps for synthesizing gold nanoparticle seeds, diffusing Sn into the seeds by chemical reduction, and the optical and structural analysis by UV-visible spectroscopy, X-ray diffraction, and electron microscopy. For complete details on the use and execution of this protocol, please refer to Fonseca Guzman et al.1.


Asunto(s)
Nanopartículas del Metal , Estaño , Estaño/química , Oro/química , Aleaciones de Oro , Plata/química , Nanopartículas del Metal/química
13.
Biomater Sci ; 11(14): 4874-4889, 2023 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-37293878

RESUMEN

Bacterial infection seriously restricts the wound healing process due to severe inflammation and delayed wound healing. Unfortunately, the overuse or improper use of antibiotics leads to the advent of multidrug-resistant strains and intractable biofilms, severely affecting the therapeutic effect. Therefore, there is an urgent need to develop antibiotic-free strategies to accelerate the healing process of wounds with bacterial infection. Considering that single photothermal therapy (PTT) or photodynamic therapy (PDT) cannot fully meet the requirements of clinical sterilization and accelerating wound healing, herein, hollow silver-gold alloy nanoparticles immobilized with the photosensitizer molecule Ce6 (Ag@Au-Ce6 NPs) integrated with PTT and PDT are proposed for killing bacteria and accelerating wound healing. The photothermal conversion properties of Ag@Au-Ce6 NPs are obtained using an infrared thermal imager, and the generation of singlet oxygen (1O2) is verified with an 1O2 fluorescent probe DCFH-DA. Manipulated by near-infrared laser triggered mild hyperthermia and limited ROS amount, Ag@Au-Ce6 NPs could effectively kill bacteria that are free and colonized on the surface of wounded skin, promoting epithelium migration and vascularization, further accelerating wound healing, which showed great promise for biomedical application.


Asunto(s)
Infecciones Bacterianas , Nanopartículas del Metal , Fotoquimioterapia , Humanos , Aleaciones de Oro/farmacología , Plata/farmacología , Terapia Fototérmica , Nanopartículas del Metal/uso terapéutico , Fármacos Fotosensibilizantes/farmacología , Fármacos Fotosensibilizantes/uso terapéutico , Cicatrización de Heridas , Infecciones Bacterianas/tratamiento farmacológico , Aceleración
14.
J Prosthodont Res ; 67(1): 150-156, 2023 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-35569998

RESUMEN

PURPOSE: To clarify the effect of a multi-purpose primer combining several functional monomers on two prosthodontic materials (cast titanium and a gold alloy) after airborne-particle abrasion. METHODS: Disk-shaped adherends were prepared from cast titanium (CP Titanium JIS2) and a gold alloy (Casting Gold M.C. Type IV). A silane-containing two-liquid primer (M&C primer (MC)) and two silane-free single-liquid primers (Alloy Primer (AP) and V-Primer (VP)) were used as surface-treatment agents. The shear bond strengths were determined before and after thermocycling to evaluate the adhesive durability, and the results were compared using a non-parametric statistical analysis. The effect of airborne-particle abrasion with alumina on the titanium surface was analyzed by X-ray photoelectron spectroscopy (XPS). RESULTS: There was no significant difference in bond strength between the MC and AP before and after thermocycling, whereas VP showed significantly lower values. XPS revealed that the titanium acquired hydrophilic properties after the airborne-particle abrasion. CONCLUSIONS: The novelty of this study is that it shows that the presence/absence of the silane had no effect on the bonding of cast titanium with an acrylic resin. The study also showed that the multi-purpose primer can be used without any problems with both cast titanium and gold alloy, in combination with airborne-particle abrasion with alumina.


Asunto(s)
Resinas Acrílicas , Recubrimiento Dental Adhesivo , Resinas Acrílicas/química , Aleaciones de Oro/química , Titanio/química , Metacrilatos/química , Resistencia al Corte , Óxido de Aluminio/química , Ensayo de Materiales , Cementos de Resina/química , Propiedades de Superficie
15.
Rev. ADM ; 79(6): 325-331, nov.-dic. 2022. ilus
Artículo en Español | LILACS | ID: biblio-1435463

RESUMEN

Los logros de los avances obtenidos en el manejo actual de la caries han dado la oportunidad a los odontólogos de detectar lesiones de caries en sus estadios incipientes. A pesar de la existencia de una gran variedad de materiales restauradores directos disponibles en el mercado actual y que pueden utilizarse para restaurar lesiones pequeñas de caries, el material que tiene más posibilidades de éxito para este tipo de lesiones es sin duda alguna el oro cohesivo, también conocido como oro directo (AU)


The goals obtained with the current management of dental caries has given the dentists the opportunity to detect incipient caries lesions in early stages. Although, the current existence of a great variety of direct restorative materials available in the market to restore small caries lesions, the material that may show better success for these type of lesions, is without any doubt: the gold foil or direct gold (AU)


Asunto(s)
Humanos , Caries Dental , Restauración Dental Permanente/instrumentación , Tratamiento Conservador , Aleaciones de Oro/uso terapéutico , Fenómenos Químicos
16.
Int J Mol Sci ; 23(22)2022 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-36430610

RESUMEN

This work deals with a physical and chemical surface characterization of quaternary 18K, 14K, and 9K gold alloys and pure polycrystalline gold substrates. Surface microstructure and composition are evaluated by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and X-ray fluorescence spectroscopy. Corrosion resistance of 18K gold alloys is explored by potentiodynamic polarization showing the influence of the manufacturing process on materials fabricated as plates and wires. The research is also in the framework of one of the most common strategies on the modification of metallic surface properties, i.e., the building of self-assembled monolayers (SAM) from organic thiols. The metal affinity of the head group to produce the coating of the substrate by covalent binding is approached by using thiol compounds with different molecular structures and functional group chemistries exposed to an electrolyte solution. Therefore, a comparative study on the surface protection of a quaternary 18K gold alloy and pure gold substrates by SAMs of 6-mercaptopurine (6MP), 1-decanethiol (DT), and 11-mercaptoundecanoic acid (MUA) has been carried out. Surface modification and SAM organization are followed by cyclic voltammetry (CV), and the behavior of the double layer of the electrode-electrolyte interface is evaluated by electrochemical impedance spectroscopy (EIS). The study of these materials allows us to extract fundamental knowledge for its potential application in improving the bioactive properties of different jewelry pieces based on 18K gold alloys.


Asunto(s)
Aleaciones de Oro , Compuestos de Sulfhidrilo , Compuestos de Sulfhidrilo/química , Corrosión , Oro/química , Propiedades de Superficie
17.
Anal Methods ; 14(45): 4713-4720, 2022 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-36342011

RESUMEN

Carcinoembryonic antigen (CEA) is regarded as a promising broad spectrum tumor biomarker for clinical diagnosis, progression, and prognosis. Surface plasmon resonance imaging (SPRi) was considered as one of the powerful tools for immunoassay with advantages of label-free, real-time detection with high-throughput. Herein, wavy gold-silver alloy nanoplates functionalized with anti-CEA antibodies providing high protein loading capacity and high mass are used as signal enhancers for CEA detection through SPRi sandwich assay. The present method exhibits a dynamic range for CEA determination from 0.1 to 312.5 ng mL-1 and a detection limit of 0.55 ng mL-1, well below normal physiological levels. This biosensing approach demonstrates the advantages of wavy gold-silver alloy nanoplates compared to conventional gold nanoparticles as a signal amplifier to enhance the SPRi signal, which is expected to become a new prospect for detection of cancer markers in biomedical research and clinical diagnosis.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Oro , Resonancia por Plasmón de Superficie/métodos , Antígeno Carcinoembrionario , Plata , Aleaciones de Oro , Técnicas Biosensibles/métodos
18.
Angew Chem Int Ed Engl ; 61(48): e202213930, 2022 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-36194372

RESUMEN

On-site hydrogen peroxide production through electrocatalytic and photocatalytic oxygen reduction reactions has recently attracted broad research interest. However, practical applications have thus far been plagued by the low activity and the requirement of complex equipment. Here, inspired by the process of biological hydrogen peroxide synthesis catalyzed by enzymes, we report a Pt-Au alloy to mimic the catalytic function of natural formate oxidase for hydrogen peroxide synthesis through aerobic oxidation of formic acid. The mass activity of the Pt-Au alloy is three times higher than that of formate oxidase. Density functional theory calculations revealed that the efficient dehydrogenation of formic acid and the high selectivity of the subsequent reduction of oxygen to hydrogen peroxide account for the high hydrogen peroxide productivity. In addition, the formic acid aqueous solution provides an acidic environment, which is conducive to the utilization of the in situ generated hydrogen peroxide for oxidation reactions, including C-H bond oxidation and sterilization.


Asunto(s)
Peróxido de Hidrógeno , Platino (Metal) , Platino (Metal)/química , Aleaciones de Oro , Formiatos/química , Oxidación-Reducción , Aleaciones/química , Oxidorreductasas , Oxígeno
19.
J Esthet Restor Dent ; 34(8): 1147-1155, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36052667

RESUMEN

BACKGROUND: The prosthetic screw fixes the prostheses to the implants. Upon osteointegration, the untightening of the prosthetic screw is the most common problem in oral rehabilitation with implants. OBJECTIVE: To study the deformation of the implant retaining hexagonal screw head. METHODS: This investigation used two methods for evaluating the screw head's area of deformation (mm2 ): a stereoscopic microscopy and micro computed tomography (microCT). For stereoscopic microscopy, 16 titanium alloy (T) and 16 titanium gold-plated alloy (G) screws of the Zimmer Biomet™ brand were used, divided into eight groups: group 0 (control group), groups T1 and G1 (screws tightened 10 times to 20 Ncm), the groups T2 and G2 (screws tightened 20 times to 20 Ncm) and the groups T3 and G3 (screws tightened 10 times to 30 Ncm). In the study with microCT, one screw was randomly chosen from each of the groups described above to perform the scanning by microCT. RESULTS: When comparing the type of screw material using stereoscopic microscopy, no statistically significant differences were found (p > 0.05). Contrarily, different number of successive grips and different torque value showed statistically significant differences in the head section of the retaining screws (p < 0.05). The observation by microCT showed the torque applied is crucial to the head deformation in titanium screws. In gold-plated screws the successive tightening appears to be pivotal. CONCLUSION: Titanium and gold screws tend to behave similarly. By increasing the tightening cycles and the torque values of protocols greater levels of deformations can be expected. In general, microCT data showed better results for gold-plated titanium alloy. CLINICAL SIGNIFICANCE: To control severe screw head deformation and the impossibility of untightening the implant's restoration, clinicians should avoid extreme torque values and prevent surpassing 10 tightening cycles.


Asunto(s)
Implantes Dentales , Retención de Prótesis Dentales , Pilares Dentales , Análisis del Estrés Dental/métodos , Microtomografía por Rayos X , Titanio , Microscopía , Aleaciones de Oro , Aleaciones , Oro
20.
Chem Asian J ; 17(22): e202200771, 2022 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-36089672

RESUMEN

New ternary gold alloys with low resistivities (ρ) were screened out via an interpretable machine learning strategy by using the support vector regression (SVR) model integrated with SHAP analysis. The correlation coefficient (R) and the root mean square error (RMSE) of test set were 0.876 and 0.302, respectively, indicating the strong generalization ability of the model. The average ρ of top 10 candidates was 1.22×10-7 â€…Ω m, which was 41% lower than the known minimum of 2.08×10-7 â€…Ω m. The outputs of SVR model were analyzed with the critical SHAP values including first ionization energy of C-site (584 kJ ⋅ mol-1 ), electronegativity of C-site (1.72) and the second ionization energy of B-site (1135 kJ ⋅ mol-1 ), respectively. Moreover, an online web server was developed to share the model at http://materials-data-mining.com/onlineservers/wxdaualloy.


Asunto(s)
Aleaciones de Oro , Aprendizaje Automático
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...