Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 211
Filtrar
1.
Open Heart ; 11(2)2024 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-39349050

RESUMEN

AIMS: To assess the diagnostic accuracy of dobutamine stress echocardiography (DSE) in symptomatic patients with a low to intermediate pretest probability of obstructive coronary artery disease (CAD) and a positive coronary CT angiography (CCTA). METHODS: We prospectively enrolled 104 consecutive patients undergoing coronary angiography for symptoms of stable CAD and a CCTA indicative of obstructive CAD. The diagnostic performance of DSE was evaluated against two intracoronary pressure indices: (a) fractional flow reserve (FFR) with a cut-off of ≤0.80 and (b) instantaneous wave-free ratio (iFR) with a cut-off of ≤0.89, indicating haemodynamically significant stenoses. RESULTS: Of 102 patients, 46 (45%) had at least one significant lesion as defined by FFR, as did 37 (36%) as defined by iFR. DSE showed positive results in 33% (34/102) of cases. The discriminative power of DSE for detecting significant CAD was moderate, with areas under the curve of 0.63 (p=0.024) compared with FFR and 0.64 (p=0.025) compared with iFR. The accuracy, sensitivity and specificity of DSE were, respectively, 61%, 43%, and 75% against FFR, and 64%, 46% and 74% against iFR. The diagnostic accuracy of DSE did not differ significantly between FFR and iFR as a reference (p=0.549). CONCLUSION: In patients with positive CCTA, DSE has a moderate ability to identify haemodynamically significant CAD, with low sensitivity and moderate specificity. When assessed against FFR and iFR criteria, its additive diagnostic value is limited in patients with low to intermediate pretest probability of obstructive CAD. TRIAL REGISTRATION NUMBER: NCT03045601.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Ecocardiografía de Estrés , Reserva del Flujo Fraccional Miocárdico , Valor Predictivo de las Pruebas , Humanos , Reserva del Flujo Fraccional Miocárdico/fisiología , Masculino , Femenino , Ecocardiografía de Estrés/métodos , Ecocardiografía de Estrés/normas , Estudios Prospectivos , Angiografía Coronaria/métodos , Persona de Mediana Edad , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico , Reproducibilidad de los Resultados , Angiografía por Tomografía Computarizada/métodos , Angiografía por Tomografía Computarizada/normas , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Dobutamina/administración & dosificación , Estándares de Referencia
2.
J Cardiovasc Comput Tomogr ; 18(5): 429-443, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38849237

RESUMEN

In current clinical practice, qualitative or semi-quantitative measures are primarily used to report coronary artery disease on cardiac CT. With advancements in cardiac CT technology and automated post-processing tools, quantitative measures of coronary disease severity have become more broadly available. Quantitative coronary CT angiography has great potential value for clinical management of patients, but also for research. This document aims to provide definitions and standards for the performance and reporting of quantitative measures of coronary artery disease by cardiac CT.


Asunto(s)
Angiografía por Tomografía Computarizada , Consenso , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Humanos , Angiografía por Tomografía Computarizada/normas , Angiografía Coronaria/normas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Valor Predictivo de las Pruebas , Pronóstico , Interpretación de Imagen Radiográfica Asistida por Computador/normas , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
4.
J Vasc Surg ; 80(3): 937-945, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38462062

RESUMEN

OBJECTIVE: Management of follow-up protocols after endovascular aortic repair (EVAR) varies significantly between centers and is not standardized according to sac regression. By designing an international expert-based Delphi consensus, the study aimed to create recommendations on follow-up after EVAR according to sac evolution. METHODS: Eight facilitators created appropriate statements regarding the study topic that were voted, using a 4-point Likert scale, by a selected panel of international experts using a three-round modified Delphi consensus process. Based on the experts' responses, only those statements reaching a grade A (full agreement ≥75%) or B (overall agreement ≥80% and full disagreement <5%) were included in the final document. RESULTS: One-hundred and seventy-four participants were included in the final analysis, and each voted the initial 29 statements related to the definition of sac regression (Q1-Q9), EVAR follow-up (Q10-Q14), and the assessment and role of sac regression during follow-up (Q15-Q29). At the end of the process, 2 statements (6.9%) were rejected, 9 statements (31%) received a grade B consensus strength, and 18 (62.1%) reached a grade A consensus strength. Of 27 final statements, 15 (55.6%) were classified as grade I, whereas 12 (44.4%) were classified as grade II. Experts agreed that sac regression should be considered an important indicator of EVAR success and always be assessed during follow-up after EVAR. CONCLUSIONS: Based on the elevated strength and high consistency of this international expert-based Delphi consensus, most of the statements might guide the current clinical management of follow-up after EVAR according to the sac regression. Future studies are needed to clarify debated issues.


Asunto(s)
Aneurisma de la Aorta Abdominal , Consenso , Técnica Delphi , Reparación Endovascular de Aneurismas , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/normas , Angiografía por Tomografía Computarizada/normas , Reparación Endovascular de Aneurismas/efectos adversos , Reparación Endovascular de Aneurismas/normas , Valor Predictivo de las Pruebas , Factores de Tiempo , Resultado del Tratamiento
5.
Can Assoc Radiol J ; 75(3): 488-501, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38486401

RESUMEN

Imaging the heart is one of the most technically challenging applications of Computed Tomography (CT) due to the presence of cardiac motion limiting optimal visualization of small structures such as the coronary arteries. Electrocardiographic gating during CT data acquisition facilitates motion free imaging of the coronary arteries. Since publishing the first version of the Canadian Association of Radiologists (CAR) cardiac CT guidelines, many technological advances in CT hardware and software have emerged necessitating an update. The goal of these cardiac CT practice guidelines is to present an overview of the current evidence supporting the use of cardiac CT in various clinical scenarios and to outline standards of practice for patient safety and quality of care when establishing a cardiac CT program in Canada.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Humanos , Angiografía por Tomografía Computarizada/métodos , Angiografía por Tomografía Computarizada/normas , Angiografía Coronaria/métodos , Canadá , Sociedades Médicas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen
6.
Neurol Sci ; 45(8): 3901-3905, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38429470

RESUMEN

OBJECTIVE: To investigate the clinical value of multi-slice spiral computed tomography angiography (MSCTA) in the diagnosis of intracranial aneurysms (ICA). METHODS: The imaging data of 68 patients suspected of having ICA who were examined in the Department of Radiology of the First Affiliated Hospital of Nanjing Medical University from March 2018 to March 2021 were retrospectively analyzed. MSCTA and digital subtraction angiography (DSA) were performed on each patient, and the MSCTA imaging analysis was compared with DSA. RESULTS: The accuracy of DSA in the diagnosis of ICA was 98.53% (67/68), while the accuracy of MSCTA in the diagnosis of ICA was 97.06% (66/68), with no significant difference in diagnostic accuracy (P > 0.05). There were no significant differences in the diameter of the aneurysm, the width of the aneurysm neck, or the location of the aneurysm in the comparison of the ICA image between DSA and MSCTA (P > 0.05). CONCLUSION: MSCTA offers high accuracy and has favorable clinical value in the diagnosis of ICA. It is worth popularizing as the recommended examination method in clinical practice.


Asunto(s)
Angiografía de Substracción Digital , Angiografía por Tomografía Computarizada , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Femenino , Persona de Mediana Edad , Masculino , Estudios Retrospectivos , Angiografía de Substracción Digital/métodos , Angiografía por Tomografía Computarizada/normas , Angiografía por Tomografía Computarizada/métodos , Adulto , Anciano , Angiografía Cerebral/métodos , Angiografía Cerebral/normas , Tomografía Computarizada Espiral/métodos
7.
J Clin Epidemiol ; 170: 111306, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38428541

RESUMEN

OBJECTIVES: To systematically evaluate the reproducibility of primary data and, the reproducibility and correctness of pooled sensitivity and specificity estimates reported in a sample of diagnostic meta-analyses. STUDY DESIGN AND SETTING: We conducted an exemplary systematic review of diagnostic meta-analyses comparing coronary computed tomography angiography to invasive coronary angiography in patients with suspected coronary artery disease. The objectives were to assess 1) the reproducibility of contingency tables, 2) the reproducibility of pooled sensitivity and specificity, and 3) differences to reported results when applying a recommended bivariate binomial model for pooling sensitivity and specificity. Therefore, we reproduced the contingency tables and recalculated sensitivity and specificity by utilizing both the pooling method of each meta-analysis and a bivariate binomial model. We used linear trends to assess the improvement of these objectives over time. RESULTS: We identified 38 diagnostic meta-analyses, each including on average 19 primary studies (range: 3 to 89 studies; total: 715-including duplicates) with an average of approximately 1800 patients per meta-analysis (range: 118 to 7516 patients). For 31 meta-analyses (82%, 95% CI: 65%, 91%), the contingency tables were reproducible; however, only 15 published them. Using the pooling method of each meta-analysis, we obtained comparable recalculated sensitivities/specificities for 28 meta-analyses (74% [57%, 86%]). Only 11 meta-analyses pooled sensitivity/specificity using a bivariate binomial model (29% [16%, 46%]). When all meta-analyses were pooled with this model, published sensitivities/specificities were confirmed for 19 of 38 meta-analyses (50% [34%, 66%]). There was only marginal improvement in data availability and application of recommended pooling methods over time. CONCLUSION: Data sharing should become standard practice along with the use of appropriate pooling methods. Journal publication requirements may play a key role in enhancing the quality of scientific reporting and methodological standards which may lead to more reliable and consistent outcomes. The ability to reproduce sensitivity and specificity estimates in diagnostic imaging meta-analyses is dependent on the availability of contingency tables and the explicit reporting of pooling methods and software used.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Sensibilidad y Especificidad , Humanos , Angiografía por Tomografía Computarizada/normas , Angiografía por Tomografía Computarizada/métodos , Angiografía por Tomografía Computarizada/estadística & datos numéricos , Reproducibilidad de los Resultados , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Angiografía Coronaria/métodos , Angiografía Coronaria/normas , Metaanálisis como Asunto
9.
J Oral Maxillofac Surg ; 80(8): 1434-1444, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35461799

RESUMEN

BACKGROUND: Virtual surgical planning (VSP), computer aided design/computer aided modeling, and 3-dimensional printing technology have been shown to improve surgical accuracy and efficiency in head and neck reconstruction. However, persisting criticism of the technology is that it does not adequately address the soft tissue-related aspects of reconstructive surgery. Prior publication on the computed tomographic angiography (CTA) perforator localization technique has demonstrated how soft tissue planning can be incorporated directly into existing VSP workflows. PURPOSE: The aim of this study is to prospectively assess the accuracy, precision, negative predictive value (NPV), and positive predictive value (PPV) of the CTA perforator localization technique for VSP of osteocutaneous fibular free flaps. MATERIALS AND METHODS: A prospective observational study in a consecutive cohort of subjects undergoing VSP of osteocutaneous fibular free flaps at Mayo Clinic between 2018 and 2020 was completed. All cutaneous perforators from the peroneal system of the selected donor leg were identified preoperatively through a previously reported CTA tracing method and registered into the VSP. Perforators were classified as primary or secondary based on whether the perforators were targeted for use in the final reconstructive plan. Perforator measurements obtained from the VSP were cross-referenced with intraoperatively obtained measurements of actual perforator locations to calculate accuracy, precision, NPV, PPV, sensitivity, and specificity of the CTA localization technique. RESULTS: Sixty consecutive subjects were enrolled in the study. A total of 141 perforators were identified preoperatively on CTA and 145 perforators were identified on operative exposure. One perforator identified on preoperative CTA was not identified on surgical exposure (false positive perforator). Six perforators were identified on operative exposure alone without recognition on preoperative CTA (false negative perforators). The accuracy of CTA perforator identification was 96.52%. Median precision of perforator localization was 0.3 cm (standard deviation 0.40) between CTA and operatively identified locations. PPV of the technique was 99.29% and NPV was 90.00%. CONCLUSION: The CTA localization technique for identifying and incorporating cutaneous perforator locations into VSP of osteocutaneous fibular free flaps is a reliable, accurate, and precise technique to employ in the modern paradigm of guided surgery for head and neck reconstruction.


Asunto(s)
Angiografía por Tomografía Computarizada , Peroné , Colgajos Tisulares Libres , Neoplasias de Cabeza y Cuello , Procedimientos de Cirugía Plástica , Angiografía/métodos , Trasplante Óseo/métodos , Angiografía por Tomografía Computarizada/normas , Peroné/irrigación sanguínea , Peroné/diagnóstico por imagen , Peroné/trasplante , Colgajos Tisulares Libres/irrigación sanguínea , Cabeza , Neoplasias de Cabeza y Cuello/cirugía , Humanos , Colgajo Perforante , Estudios Prospectivos , Procedimientos de Cirugía Plástica/métodos , Tomografía Computarizada por Rayos X/métodos
10.
Ann Vasc Surg ; 79: 264-272, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34656714

RESUMEN

BACKGROUND: There is no consensus on the method of obtaining abdominal aortic aneurysm (AAA) maximum diameters based on computed tomographic angiography, and the reproducibility and accuracy of different methods have recently been debated due to advancements in imaging. This study compared the two most common methods based on orthogonal planes and centerline of flow to determine the discordances and accuracy amongst experiences readers. METHODS: The computed tomographic angiography max diameters of 148 AAAs were measured by three experienced observers, including a vascular surgeon, a radiologist and an imaging cardiologist. Observers used two different methods with standardized protocols: multiplanar reformations based on orthogonal planes, and a software using 3D aortic reconstructions to create centerline flow lumen providing diameters based on cross sections perpendicular to this lumen. Agreements and reliability of measurement methods were assessed by intra-class correlation coefficient and Bland - Altman analysis. Discordances between measurements of the methods and the original reported measurement, as well as outside hospitals were compared. RESULTS: The average age of the cohort was 75 years and aortic diameters ranged from 3.8 to 9.6 cm. For orthogonal readings, there were agreements within 3 mm between 86% and 92% of the time, while centerline - reading agreement was between 88% and 94%, which was not statistically significant. The intra-class correlation coefficient was high between method type and between readers. Within methods, agreement was between 0.96 and 0.97, while within - reader agreement measures was between 0.96 and 0.98. In comparison to the original and the outside hospital reports, 10% ≥ of the original and 20% ≥ of the outside hospital reported measurements were discordant between the readers. CONCLUSION: Maximal AAA measurements can have substantial variability leading to clinical significance and change in patient management and outcomes. Based on the results, orthogonal and centerline measurement methods have equally high agreements and concordance within 3 mm and low variations at a high volume center. However, when compared to the official read reports, there is high discordance rates that can significantly alter patient outcomes. A standardized method of measurement maximum diameter can reduce variations and discordances among different methods.


Asunto(s)
Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/normas , Angiografía por Tomografía Computarizada/normas , Anciano , Anciano de 80 o más Años , Dilatación Patológica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos
11.
World Neurosurg ; 157: e22-e28, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34555573

RESUMEN

BACKGROUND: Cervical pedicle screws (CPS) in the subaxial cervical spine (C3-C6) are faced with high incidence of perforating the lateral pedicular cortex endangering the vertebral artery (VA). The present study analyzes the pedicle width (PW) from C3 to C6 and defines the relation of VA with regard to pedicle and transverse foramen (TF) to determine the safety margin in cases of lateral pedicular breach. METHODS: Computed tomography angiograms of 500 patients were retrospectively studied to identify the pedicle width (PW), VA area, TF area, and the lateral pedicle to vertebral artery distance (LPVA). Occupancy ratio (OR; the percentage area of transverse foramen occupied by VA) and safety margin (SM; permissible displacement of VA in TF), along with LPVA were considered to be protective parameters against VA injury if lateral pedicle breach happens. RESULTS: PW was 4.7 mm at C3, 4.83 mm at C4, 5.26 mm at C5 and 5.41 mm at C6. Mean LPVA at different levels was between 0.97 mm and 1.15 mm, OR was around 20% at all levels, and mean SM was between 2.34 mm and 2.92 at various levels. Sex differences were statistically significant for PW but not for LPVA, SM, or OR. CONCLUSIONS: This study gives us an idea about the various parameters in placement of cervical pedicle screw in subaxial cervical spine and the probable reasons there are few vertebral artery injuries despite high incidence of cervical pedicle breach. LPVA, safety margin, and OR may explain why even very significant CPS misplacement does not lead to vascular injury or neurologic deficit.


Asunto(s)
Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Angiografía por Tomografía Computarizada/normas , Tornillos Pediculares/normas , Enfermedades de la Columna Vertebral/diagnóstico por imagen , Enfermedades de la Columna Vertebral/cirugía , Adulto , Anciano , Angiografía por Tomografía Computarizada/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Arteria Vertebral/diagnóstico por imagen
12.
Neurology ; 97(8): e785-e793, 2021 08 24.
Artículo en Inglés | MEDLINE | ID: mdl-34426550

RESUMEN

OBJECTIVE: To validate a previously proposed filling defect length threshold of >3.8 mm on CT angiography (CTA) to discriminate between free-floating thrombus (FFT) and plaque of atheroma. METHODS: This was a prospective multicenter observational study of 100 participants presenting with TIA/stroke symptoms and a carotid intraluminal filling defect on initial CTA. Follow-up CTA was obtained within 1 week and at weeks 2 and 4 if the intraluminal filling defect was unchanged in length. Resolution or decreased length was diagnostic of FFT, whereas its static appearance after 4 weeks was indicative of plaque. Diagnostic accuracy of FFT length was assessed by receiver operating characteristic analysis. RESULTS: Ninety-five participants (mean [SD] age 68 [13] years, 61 men, 83 participants with FFT, 12 participants with a plaque) were evaluated. The >3.8-mm threshold had a sensitivity of 88% (73 of 83) (95% confidence interval [CI] 78%-94%) and specificity of 83% (10 of 12) (95% CI 51%-97%) (area under the curve 0.91, p < 0.001) for the diagnosis of FFT. The optimal length threshold was >3.64 mm with a sensitivity of 89% (74 of 83) (95% CI 80%-95%) and specificity of 83% (10 of 12) (95% CI 51%-97%). Adjusted logistic regression showed that every 1-mm increase in intraluminal filling defect length is associated with an increase in odds of FFT of 4.6 (95% CI 1.9-11.1, p = 0.01). CONCLUSION: CTA enables accurate differentiation of FFT vs plaque using craniocaudal length thresholds. TRIAL REGISTRATION INFORMATION: ClinicalTrials.gov Identifier: NCT02405845. CLASSIFICATION OF EVIDENCE: This study provides Class I evidence that in patients with TIA/stroke symptoms, the presence of CTA-identified filling defects of lengths >3.8 mm accurately discriminates FFT from atheromatous plaque.


Asunto(s)
Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Angiografía por Tomografía Computarizada/normas , Ataque Isquémico Transitorio/diagnóstico por imagen , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico por imagen , Trombosis/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
13.
Cardiovasc Res ; 117(13): 2677-2690, 2021 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-34450625

RESUMEN

AIMS: Coronary computed tomography angiography (CCTA) is a first-line modality in the investigation of suspected coronary artery disease (CAD). Mapping of perivascular fat attenuation index (FAI) on routine CCTA enables the non-invasive detection of coronary artery inflammation by quantifying spatial changes in perivascular fat composition. We now report the performance of a new medical device, CaRi-Heart®, which integrates standardized FAI mapping together with clinical risk factors and plaque metrics to provide individualized cardiovascular risk prediction. METHODS AND RESULTS: The study included 3912 consecutive patients undergoing CCTA as part of clinical care in the USA (n = 2040) and Europe (n = 1872). These cohorts were used to generate age-specific nomograms and percentile curves as reference maps for the standardized interpretation of FAI. The first output of CaRi-Heart® is the FAI-Score of each coronary artery, which provides a measure of coronary inflammation adjusted for technical, biological, and anatomical characteristics. FAI-Score is then incorporated into a risk prediction algorithm together with clinical risk factors and CCTA-derived coronary plaque metrics to generate the CaRi-Heart® Risk that predicts the likelihood of a fatal cardiac event at 8 years. CaRi-Heart® Risk was trained in the US population and its performance was validated externally in the European population. It improved risk discrimination over a clinical risk factor-based model [Δ(C-statistic) of 0.085, P = 0.01 in the US Cohort and 0.149, P < 0.001 in the European cohort] and had a consistent net clinical benefit on decision curve analysis above a baseline traditional risk factor-based model across the spectrum of cardiac risk. CONCLUSION: Mapping of perivascular FAI on CCTA enables the non-invasive detection of coronary artery inflammation by quantifying spatial changes in perivascular fat composition. We now report the performance of a new medical device, CaRi-Heart®, which allows standardized measurement of coronary inflammation by calculating the FAI-Score of each coronary artery. The CaRi-Heart® device provides a reliable prediction of the patient's absolute risk for a fatal cardiac event by incorporating traditional cardiovascular risk factors along with comprehensive CCTA coronary plaque and perivascular adipose tissue phenotyping. This integration advances the prognostic utility of CCTA for individual patients and paves the way for its use as a dual diagnostic and prognostic tool among patients referred for CCTA.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Angiografía por Tomografía Computarizada/normas , Angiografía Coronaria/normas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Técnicas de Apoyo para la Decisión , Inflamación/diagnóstico por imagen , Nomogramas , Adiposidad , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Nube Computacional , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/terapia , Inglaterra , Femenino , Alemania , Factores de Riesgo de Enfermedad Cardiaca , Humanos , Inflamación/mortalidad , Inflamación/terapia , Masculino , Persona de Mediana Edad , Ohio , Valor Predictivo de las Pruebas , Pronóstico , Medición de Riesgo , Factores de Tiempo , Adulto Joven
14.
Stroke ; 52(8): 2723-2733, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34233464

RESUMEN

BACKGROUND AND PURPOSE: The Stroke Treatment Academic Industry Roundtable (STAIR) sponsored an imaging session and workshop during the Stroke Treatment Academic Industry Roundtable XI via webinar on October 1 to 2, 2020, to develop consensus recommendations, particularly regarding optimal imaging at primary stroke centers. METHODS: This forum brought together stroke neurologists, neuroradiologists, neuroimaging research scientists, members of the National Institute of Neurological Disorders and Stroke, industry representatives, and members of the US Food and Drug Administration to discuss imaging priorities in the light of developments in reperfusion therapies, particularly in an extended time window, and reinvigorated interest in brain cytoprotection trials. RESULTS: The imaging session summarized and compared the imaging components of recent acute stroke trials and debated the optimal imaging strategy at primary stroke centers. The imaging workshop developed consensus recommendations for optimizing the acquisition, analysis, and interpretation of computed tomography and magnetic resonance acute stroke imaging, and also recommendations on imaging strategies for primary stroke centers. CONCLUSIONS: Recent positive acute stroke clinical trials have extended the treatment window for reperfusion therapies using imaging selection. Achieving rapid and high-quality stroke imaging is therefore critical at both primary and comprehensive stroke centers. Recommendations for enhancing stroke imaging research are provided.


Asunto(s)
Ensayos Clínicos como Asunto/métodos , Angiografía por Tomografía Computarizada/métodos , Conferencias de Consenso como Asunto , Imagen por Resonancia Magnética/métodos , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Ensayos Clínicos como Asunto/normas , Angiografía por Tomografía Computarizada/normas , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/normas , Humanos , Imagen por Resonancia Magnética/normas , Accidente Cerebrovascular/terapia , Tomografía Computarizada por Rayos X/normas , Resultado del Tratamiento
15.
J Clin Neurosci ; 89: 133-138, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34119256

RESUMEN

OBJECTIVES: The role of an early CTA approach in neurologically stable patients with nontraumatic SAH has not been assessed. This study explored the use of CTA in clinically stable SAH patients to pre-emptively identify cerebral vasospasm, to evaluate whether this approach is associated with improved clinical outcomes. METHODS: We conducted a retrospective chart review of SAH patients presenting between July 2007 and December 2016 in a single academic center. Patients were divided into two groups: (1) Early CTA (stable patients who underwent a CTA between days 5-8 post-SAH), and (2) Standard Protocol. The co-primary outcomes were a composite of the mRS at discharge and last clinical follow-up (good = 0-2; poor = 3-6). A multivariable binary logistic regression was conducted to compare both groups against outcomes, controlling for potential confounders. RESULTS: A total of 415 patients were included, 103 (24.8%) with early CTA, and 312 (75.2%) undergoing the standard protocol; the mean age was 57 years and 248 (59.8%) patients were female. Patients in the early CTA group had a higher modified Fisher grade (3-4) (87.4% vs 63.1%; p < 0.02). The multivariable analysis showed that early CTA was independently associated with lower poor outcomes at discharge (OR = 0.21, 95% CI 0.07-0.61, p = 0.004). Plus, vasospasm detection was associated with an increased risk of poor outcomes (OR = 4.77, 95% CI 1.41 - 16.10, p = 0.01). Early CTA was not associated with outcomes at clinical follow-up. CONCLUSION: The early CTA surveillance approach was associated with better functional outcomes at discharge when compared to the current imaging standard practice.


Asunto(s)
Angiografía Cerebral/normas , Angiografía por Tomografía Computarizada/normas , Hemorragia Subaracnoidea/diagnóstico por imagen , Hemorragia Subaracnoidea/terapia , Adulto , Anciano , Angiografía Cerebral/métodos , Angiografía Cerebral/tendencias , Angiografía por Tomografía Computarizada/métodos , Angiografía por Tomografía Computarizada/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Tomografía Computarizada por Rayos X/tendencias , Resultado del Tratamiento
16.
Medicine (Baltimore) ; 100(22): e26213, 2021 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-34087898

RESUMEN

ABSTRACT: Pulmonary embolism (PE) is a common medical problem. Its diagnostic criteria must be reviewed to determine the need for confirmatory testing. Computed tomography pulmonary angiography (CTPA) is the current standard of care, which provides accurate diagnosis with rapid turnaround. This study aimed to estimate the diagnostic yield of CTPA in clinically suspected PE patients in a tertiary care hospital in Saudi Arabia.Radiology records of all patients with clinically suspected PE who underwent CTPA between January 1, 2012 and September 30, 2018 were reviewed retrospectively. A radiologist with 10 years of professional experience interpreted and reported all cases. The Wells score with 2 tiers (likely and unlikely) was used to raise the clinical suspicion of PE.Positive results for PE were reported in 177 out of 534 clinically suspected cases (33%). Among the positive PE cases, 143 were acute (81%) and 34 (19%) were chronic. Bilateral, right-sided, and left-sided PE were found in 115 (65%), 37 (21%), and 25 (14%) cases, respectively. Involvement of the segmental branches, subsegmental branches, and the pulmonary trunk were noted in 152 (86%), 70 (40%), and 9 cases (5%), respectively. Saddle PE was found in (4%) of the cases. The lower lobe branches (right 55%, left 53%) and the upper lobe branches (right 47%, left 41%) were the most common sites of involvement.CTPA had a higher positive detection rate for PE among clinically suspected cases than its published diagnostic yield. Adequate clinical evaluation when selecting patients for CTPA is emphasized to minimize unjustified exposure of the patients to radiation and intravenous contrast administration. It is crucial for radiologists to provide detailed reports commenting on all relevant findings, including pertinent negatives. A template for reporting radiological findings for CTPA can be recommended for this purpose.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Medios de Contraste/efectos adversos , Pulmón/irrigación sanguínea , Embolia Pulmonar/diagnóstico , Exposición a la Radiación/efectos adversos , Administración Intravenosa , Adulto , Anciano , Angiografía por Tomografía Computarizada/normas , Medios de Contraste/administración & dosificación , Femenino , Humanos , Pulmón/fisiopatología , Masculino , Persona de Mediana Edad , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/epidemiología , Exposición a la Radiación/prevención & control , Estudios Retrospectivos , Arabia Saudita/epidemiología , Centros de Atención Terciaria
18.
J Vasc Surg ; 74(5): 1438-1439, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34022379
19.
BMC Cardiovasc Disord ; 21(1): 154, 2021 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-33771107

RESUMEN

BACKGROUND: Appropriate use criteria (AUC) have been developed in response to growth in cardiac imaging utilization and concern regarding associated costs. Cardiac computed tomography angiography (CCTA) has emerged as an important modality in the evaluation of coronary artery disease, however its appropriate utilization in actual practice is uncertain. Our objective was to determine the appropriate utilization of CCTA in a large quaternary care institution and to compare appropriate utilization pre and post publication of the 2013 AUC guidelines. We hypothesized that the proportion of appropriate CCTA utilization will be similar to those of other comparable cardiac imaging modalities and that there would be a significant increase in appropriate use post AUC publication. METHODS: We employed a retrospective cohort study design of 2577 consecutive patients undergoing CCTA between January 1, 2012 and December 30, 2016. An appropriateness category was assigned for each CCTA. Appropriateness classifications were compared pre- and post- AUC publication via the chi-square test. RESULTS: Overall, 83.5% of CCTAs were deemed to be appropriate based on the AUC. Before the AUC publication, 75.0% of CCTAs were classified as appropriate whereas after the AUC publication, 88.0% were classified as appropriate (p < 0.001). The increase in appropriate utilization, when extrapolated to the Medicare population of the United States, was associated with potential cost savings of approximately $57 million per year. CONCLUSIONS: We report a high rate of appropriate use of CCTA and a significant increase in the proportion of CCTAs classified as appropriate after the AUC publication.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Pautas de la Práctica en Medicina , Anciano , Angiografía por Tomografía Computarizada/economía , Angiografía por Tomografía Computarizada/normas , Angiografía Coronaria/economía , Angiografía Coronaria/normas , Análisis Costo-Beneficio , Femenino , Adhesión a Directriz , Costos de la Atención en Salud , Humanos , Masculino , Medicare , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Pautas de la Práctica en Medicina/economía , Pautas de la Práctica en Medicina/normas , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Estados Unidos
20.
Intern Emerg Med ; 16(8): 2251-2259, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33742340

RESUMEN

Pulmonary embolism (PE) remains a diagnostic challenge in emergency medicine. Clinical decision aids (CDAs) like the Pulmonary Embolism Rule-Out Criteria (PERC) are sensitive but poorly specific; serial CDA use may improve specificity. The goal of this before-and-after study was to determine if serial use of existing CDAs in a novel diagnostic algorithm safely decreases the use of CT pulmonary angiograms (CTPA). This was a retrospective before-and-after study conducted at an urban ED with 105,000 annual visits. Our algorithm uses PERC, Wells' score, and D-dimer in series, before moving to CTPA. The algorithm was introduced in January, 2017. Use of CDAs and D-dimer in the 24 months pre- and 12 months post-intervention were obtained by chart review. The algorithm's effect on CTPA ordering was assessed by comparing volume 5 years pre- and 3 years post-intervention, adjusted for ED volume. Mean CTPAs per 1000 adult ED visits was 11.1 in the 5 pre-intervention years and 9.9 in the 3 post-intervention years (p < 0.0001). Use of PERC, Wells' score and D-dimer increased from 1.1%, 1.1%, and 28% to 8.8% (p = 0.0002) 8.1% (p = 0.0005), and 35% (p = 0.0066), respectively. Pre-intervention, there were six potentially missed PEs compared to three in the post-intervention period. Introduction of our serial CDA diagnostic algorithm was associated with increased use of CDAs and D-dimer and reduced CTPA rate without an apparent increase in the number of missed PEs. Prospective validation is needed to confirm these results.


Asunto(s)
Angiografía por Tomografía Computarizada/normas , Sistemas de Apoyo a Decisiones Clínicas/estadística & datos numéricos , Uso Excesivo de los Servicios de Salud/prevención & control , Pautas de la Práctica en Medicina/normas , Embolia Pulmonar/diagnóstico por imagen , Algoritmos , Angiografía por Tomografía Computarizada/métodos , Estudios Controlados Antes y Después , Sistemas de Apoyo a Decisiones Clínicas/instrumentación , Humanos , Uso Excesivo de los Servicios de Salud/estadística & datos numéricos , Aceptación de la Atención de Salud/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Embolia Pulmonar/diagnóstico , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...