Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.862
Filtrar
1.
Virol J ; 21(1): 148, 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38951814

RESUMEN

The magnitude of the HIV-1 epidemic in Nigeria is second only to the subtype C epidemic in South Africa, yet the subtypes prevalent in Nigeria require further characterization. A panel of 50 subtype G and 18 CRF02_AG Nigerian HIV-1 pseudoviruses (PSV) was developed and envelope coreceptor usage, neutralization sensitivity and cross-clade reactivity were characterized. These PSV were neutralized by some antibodies targeting major neutralizing determinants, but potentially important differences were observed in specific sensitivities (eg. to sCD4, MPER and V2/V3 monoclonal antibodies), as well as in properties such as variable loop lengths, number of potential N-linked glycans and charge, demonstrating distinct antigenic characteristics of CRF02_AG and subtype G. There was preferential neutralization of the matched CRF/subtype when PSV from subtype G or CRF02_AG were tested using pooled plasma. These novel Nigerian PSV will be useful to study HIV-1 CRF- or subtype-specific humoral immune responses for subtype G and CRF02_AG.


Asunto(s)
Anticuerpos Neutralizantes , Anticuerpos Anti-VIH , Infecciones por VIH , VIH-1 , Pruebas de Neutralización , VIH-1/inmunología , VIH-1/genética , VIH-1/clasificación , Nigeria , Anticuerpos Neutralizantes/inmunología , Anticuerpos Neutralizantes/sangre , Humanos , Anticuerpos Anti-VIH/inmunología , Anticuerpos Anti-VIH/sangre , Infecciones por VIH/inmunología , Infecciones por VIH/virología , Productos del Gen env del Virus de la Inmunodeficiencia Humana/inmunología , Productos del Gen env del Virus de la Inmunodeficiencia Humana/genética , Reacciones Cruzadas/inmunología
2.
Int J Mol Sci ; 25(13)2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-39000308

RESUMEN

Viral infection generally induces polyclonal neutralizing antibody responses. However, how many lineages of antibody responses can fully represent the neutralization activities in sera has not been well studied. Using the newly designed stable HIV-1 Env trimer as hook, we isolated two distinct broadly neutralizing antibodies (bnAbs) from Chinese rhesus macaques infected with SHIV1157ipd3N4 for 5 years. One lineage of neutralizing antibodies (JT15 and JT16) targeted the V2-apex in the Env trimers, similar to the J038 lineage bnAbs identified in our previous study. The other lineage neutralizing antibody (JT18) targeted the V3 crown region in the Env, which strongly competed with human 447-52D. Each lineage antibody neutralized a different set of viruses. Interestingly, when the two neutralizing antibodies from different lineages isolated from the same macaque were combined, the mixture had a neutralization breath very similar to that from the cognate sera. Our study demonstrated that a minimum of two different neutralizing antibodies can fully recapitulate the serum neutralization breadth. This observation can have important implications in AIDS vaccine design.


Asunto(s)
Anticuerpos Neutralizantes , Anticuerpos Anti-VIH , VIH-1 , Macaca mulatta , Síndrome de Inmunodeficiencia Adquirida del Simio , Macaca mulatta/inmunología , Animales , VIH-1/inmunología , Anticuerpos Anti-VIH/inmunología , Anticuerpos Anti-VIH/sangre , Anticuerpos Neutralizantes/inmunología , Anticuerpos Neutralizantes/sangre , Humanos , Síndrome de Inmunodeficiencia Adquirida del Simio/inmunología , Síndrome de Inmunodeficiencia Adquirida del Simio/sangre , Síndrome de Inmunodeficiencia Adquirida del Simio/virología , Infecciones por VIH/inmunología , Infecciones por VIH/virología , Infecciones por VIH/sangre , Virus de la Inmunodeficiencia de los Simios/inmunología , Productos del Gen env del Virus de la Inmunodeficiencia Humana/inmunología , Pruebas de Neutralización
3.
Viruses ; 16(7)2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-39066177

RESUMEN

We recently demonstrated that Simian-HIV (SHIV)-infected neonate rhesus macaques (RMs) generated heterologous HIV-1 neutralizing antibodies (NAbs) with broadly-NAb (bNAb) characteristics at a higher frequency compared with their corresponding dam. Here, we characterized genetic diversity in Env sequences from four neonate or adult/dam RM pairs: in two pairs, neonate and dam RMs made heterologous HIV-1 NAbs; in one pair, neither the neonate nor the dam made heterologous HIV-1 NAbs; and in another pair, only the neonate made heterologous HIV-1 NAbs. Phylogenetic and sequence diversity analyses of longitudinal Envs revealed that a higher genetic diversity, within the host and away from the infecting SHIV strain, was correlated with heterologous HIV-1 NAb development. We identified 22 Env variable sites, of which 9 were associated with heterologous HIV-1 NAb development; 3/9 sites had mutations previously linked to HIV-1 Env bNAb development. These data suggested that viral diversity drives heterologous HIV-1 NAb development, and the faster accumulation of viral diversity in neonate RMs may be a potential mechanism underlying bNAb induction in pediatric populations. Moreover, these data may inform candidate Env immunogens to guide precursor B cells to bNAb status via vaccination by the Env-based selection of bNAb lineage members with the appropriate mutations associated with neutralization breadth.


Asunto(s)
Anticuerpos Neutralizantes , Evolución Molecular , VIH-1 , Macaca mulatta , Filogenia , Síndrome de Inmunodeficiencia Adquirida del Simio , Virus de la Inmunodeficiencia de los Simios , Animales , Virus de la Inmunodeficiencia de los Simios/genética , Virus de la Inmunodeficiencia de los Simios/inmunología , Síndrome de Inmunodeficiencia Adquirida del Simio/virología , VIH-1/genética , VIH-1/inmunología , VIH-1/clasificación , Anticuerpos Neutralizantes/inmunología , Anticuerpos Neutralizantes/sangre , Variación Genética , Animales Recién Nacidos , Anticuerpos Anti-VIH/inmunología , Anticuerpos Anti-VIH/sangre , Proteínas del Envoltorio Viral/genética , Proteínas del Envoltorio Viral/inmunología , Infecciones por VIH/virología
4.
Sex Transm Dis ; 51(8): 545-547, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38989902

RESUMEN

ABSTRACT: At our medical center, HIV nucleic acid tests are recommended when the HIV antigen-antibody screening immunoassay and antibody differentiation tests are discordant, but not done reflexively. A retrospective chart review found that 35% of discordant test results did not have HIV nucleic acid test completed as recommended.


Asunto(s)
Algoritmos , Infecciones por VIH , Técnicas de Amplificación de Ácido Nucleico , Humanos , Infecciones por VIH/diagnóstico , Estudios Retrospectivos , Masculino , Femenino , Adulto , Prueba de VIH , ARN Viral , Tamizaje Masivo/métodos , Persona de Mediana Edad , VIH-1/aislamiento & purificación , VIH-1/inmunología , Anticuerpos Anti-VIH/sangre , Inmunoensayo/métodos
5.
Sci Rep ; 14(1): 13499, 2024 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-38866888

RESUMEN

Acute, transient lymphocytopenia, not clinically significant was observed in the CAPRISA 012B phase 1 clinical trial following administration of broadly neutralizing antibodies (bnAb)-CAP256V2LS alone or with VRC07-523LS. Lymphocytopenia was assigned upon a > 50% decline in absolute lymphocyte counts following bnAb administration. We posited that systemic immunoglobulins (Igs), and cytokine profiles of eight women who developed lymphocytopenia were different to the 12 women without lymphocytopenia. Plasma Ig subclasses (IgG)/isotypes (IgM/IgA), and 27 cytokines were measured at enrolment (prior to bnAbs) and at days 1, 7, 28, 56 post-bnAb administration. IgG subclasses, IgM and total lymphocyte counts were significantly lower prior to bnAbs in women with gradable lymphocytopenia than those without. Gradable lymphocytopenia compared to non-lymphocytopenia women had significantly higher MIP-1ß from enrolment up to day 56. TNF-α was significantly lower in gradable lymphocytopenia compared to non-lymphocytopenia women for enrolment, days 7, 28 and 56 except for day 1. Within the gradable and within the non-lymphocytopenia women, from enrolment to day 1, significantly elevated IL-6, IL-8, IP-10, MCP-1, G-CSF and IL-1RA were found. Additionally, within the gradable lymphocytopenia women, 9 additional cytokines (TNF-α, MIP-1α, MIP-1ß, RANTES, Basic FGF, eotaxin, IFN-γ, IL-17A and IL-4) were significantly elevated at day 1 post-bnAbs compared to enrolment. This sub study presents preliminary findings to support the monitoring of baseline immunological markers including lymphocyte counts for assessing the development of transient lymphocytopenia. In high-risk settings conducting clinical trials testing bnAbs for HIV prevention, understanding factors that could amplify rates of lymphocytopenia, even if transient, remain undefined.


Asunto(s)
Linfopenia , Humanos , Femenino , Linfopenia/inmunología , Linfopenia/sangre , Adulto , Citocinas/sangre , Infecciones por VIH/inmunología , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/sangre , Anticuerpos Anti-VIH/sangre , Anticuerpos Anti-VIH/inmunología , VIH-1/inmunología , Inmunoglobulinas/sangre , Anticuerpos Neutralizantes/sangre , Anticuerpos Neutralizantes/inmunología , Persona de Mediana Edad
6.
BMC Infect Dis ; 24(1): 587, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38879487

RESUMEN

BACKGROUND: Early diagnosis of HIV infection decreases the time from HIV diagnosis to viral suppression and reduces further HIV transmission. The Chinese Guidelines for the Diagnosis and Treatment of HIV/AIDS (2021 edition) state that an HIV RNA level > 5,000 copies/mL is the threshold for diagnosing HIV infection. The impact of low viral load values on HIV diagnosis needs to be investigated. METHODS: There were 3455 human immunodeficiency virus (HIV1 + 2) antibody results (immunoblotting method) and 65,129 HIV viral load values at Beijing Youan Hospital from 2019 to 2022. A total of 2434 patients had both antibody confirmatory results and viral load results. The confirmatory antibody results and HIV viral load results of 2434 patients were analyzed to investigate the impact of low viral load values on HIV diagnosis. RESULTS: Of the 2434 patients who had both confirmatory antibody results and viral load results, the viral load values of 140 patients (5.8%) had viral loads ranging from 40 copies/mL to 5,000 copies/mL before positive confirmatory antibody result, and of these 140 patients, the sample receipt time for the viral load tests of 96 (66.7%) individuals was 1 to 6 days earlier than the corresponding sample receipt time for the confirmatory antibody test. In addition, 34 patients (1.4%) had low viral loads ranging from 40 copies/mL to 1,000 copies/mL before positive confirmatory antibody result. CONCLUSION: This study revealed that there is a risk of missed diagnosis if a threshold of 5000 copies/mL is used for the diagnosis of HIV infection. These data provide valuable information for the early diagnosis of HIV infection, and our findings have potential benefits for decreasing HIV transmission.


Asunto(s)
Infecciones por VIH , Centros de Atención Terciaria , Carga Viral , Humanos , Infecciones por VIH/diagnóstico , Infecciones por VIH/virología , Masculino , Femenino , Adulto , Beijing , Persona de Mediana Edad , VIH-1/genética , VIH-1/aislamiento & purificación , ARN Viral/sangre , Anticuerpos Anti-VIH/sangre , Adulto Joven , China/epidemiología , Diagnóstico Precoz , Adolescente
7.
Med Microbiol Immunol ; 213(1): 10, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38907945

RESUMEN

Rapid tests allow outpatient, low cost, reliable, screening for chronic HIV infection. However, data regarding their sensitivity on primary infection remain scarce. The objective of this study was to assess sensitivity of nine HIV rapid tests for primary HIV-1 infection screening. Seventy-five serum samples from patients during HIV-1 primary infection were included. Primary infection was diagnosed by a positive 4th generation ELISA and HIV-1 RNA positivity confirmed by Western blot patterns associated with HIV-1 primary infection. Early seroconversion was defined as the absence of antibodies on HIV-1 Western blot associated with HIV-1 RNA and p24-antigen positivity. An identical sensitivity (95% CI) of 76.7% (65.2-84.2%) was observed for HIV 1/2 STAT-PAK® Assay (STAT-PAK), INSTI™ HIV-1/HIV-2 antibody Test (INSTI), SURE CHECK® HIV 1/2 (SURE CHECK) and MULTISURE HIV rapid test (MULTISURE) with visual reading. Sensitivity was 74.7% (63.8-83.1%) for MULTISURE (automatic reading), 77.0% (66.3-85.1%) for FIRST RESPONSE® Test VIH 1-2.O CARTE (FIRST RESPONSE), 83.8% (73.8-90.5%) for VIKIA HIV1/2® (VIKIA), 88.0% (78.7-93.6%) for Genie™ Fast HIV 1/2 (Genie Fast), 88.6% (79.0-94.1%) for Hexagon HIV (Hexagon), and 92.8% (83.6-96.3%) for Exacto® TEST HIV Pro (Exacto). However, rapid tests performed poorly for the early seroconversion subgroup (n = 14), with sensitivities ranging from 7% (1.3-31.5%) for STAT-PAK, INSTI, SURE CHECK, MULTISURE (automatic reading), to 29% (12-55%) for FIRST RESPONSE, 31% (13-58%) for VIKIA, 43% (21-67%) for Hexagon and 57.1% (32.6-78.6%) for Exacto and Genie Fast. Overall, despite significant discrepancies in sensitivity, HIV rapid tests should be used with caution in the context of a suspected primary infection.


Asunto(s)
Anticuerpos Anti-VIH , Infecciones por VIH , VIH-1 , Tamizaje Masivo , Sensibilidad y Especificidad , Humanos , Infecciones por VIH/diagnóstico , VIH-1/inmunología , VIH-1/aislamiento & purificación , Masculino , Tamizaje Masivo/métodos , Femenino , Adulto , Anticuerpos Anti-VIH/sangre , Persona de Mediana Edad , ARN Viral/sangre , Ensayo de Inmunoadsorción Enzimática/métodos , Adulto Joven , Western Blotting/métodos , Pruebas Diagnósticas de Rutina/métodos , Prueba de VIH/métodos
8.
PLoS Med ; 21(6): e1004329, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38913710

RESUMEN

BACKGROUND: Broadly neutralizing antibodies (bnAbs) are a promising approach for HIV-1 prevention. In the Antibody Mediated Prevention (AMP) trials, a CD4-binding site targeting bnAb, VRC01, administered intravenously (IV), demonstrated 75% prevention efficacy against highly neutralization-sensitive viruses but was ineffective against less sensitive viruses. VRC07-523LS is a next-generation bnAb targeting the CD4-binding site and was engineered for increased neutralization breadth and half-life. We conducted a multicenter, randomized, partially blinded Phase I clinical trial to evaluate the safety and serum concentrations of VRC07-523LS, administered in multiple doses and routes to healthy adults without HIV. METHODS AND FINDINGS: Participants were recruited between 2 February 2018 and 9 October 2018. A total of 124 participants were randomized to receive 5 VRC07-523LS administrations via IV (T1: 2.5 mg/kg, T2: 5 mg/kg, T3: 20 mg/kg), subcutaneous (SC) (T4: 2.5 mg/kg, T5: 5 mg/kg), or intramuscular (IM) (T6: 2.5 mg/kg or P6: placebo) routes at 4-month intervals. Participants and site staff were blinded to VRC07-523LS versus placebo for the IM group, while all other doses and routes were open-label. Safety data were collected for 144 weeks following the first administration. VRC07-523LS serum concentrations were measured by ELISA through Day 112 in all participants and by binding antibody multiplex assay (BAMA) thereafter in 60 participants (10 per treatment group) through Day 784. Compartmental population pharmacokinetic (PK) analyses were conducted to evaluate the VRC07-523LS serum PK. Neutralization activity was measured in a TZM-bl assay and antidrug antibodies (ADAs) were assayed using a tiered bridging assay testing strategy. Injections and infusions were well tolerated, with mild pain or tenderness reported commonly in the SC and IM groups, and mild to moderate erythema or induration reported commonly in the SC groups. Infusion reactions were reported in 3 of 20 participants in the 20 mg/kg IV group. Peak geometric mean (GM) concentrations (95% confidence intervals [95% CIs]) following the first administration were 29.0 µg/mL (25.2, 33.4), 58.5 µg/mL (49.4, 69.3), and 257.2 µg/mL (127.5, 518.9) in T1-T3 with IV dosing; 10.8 µg/mL (8.8, 13.3) and 22.8 µg/mL (20.1, 25.9) in T4-T5 with SC dosing; and 16.4 µg/mL (14.7, 18.2) in T6 with IM dosing. Trough GM (95% CIs) concentrations immediately prior to the second administration were 3.4 µg/mL (2.5, 4.6), 6.5 µg/mL (5.6, 7.5), and 27.2 µg/mL (23.9, 31.0) with IV dosing; 0.97 µg/mL (0.65, 1.4) and 3.1 µg/mL (2.2, 4.3) with SC dosing, and 2.6 µg/mL (2.05, 3.31) with IM dosing. Peak VRC07-523LS serum concentrations increased linearly with the administered dose. At a given dose, peak and trough concentrations, as well as serum neutralization titers, were highest in the IV groups, reflecting the lower bioavailability following SC and IM administration. A single participant was found to have low titer ADA at a lone time point. VRC07-523LS has an estimated mean half-life of 42 days across all doses and routes (95% CI: 40.5, 43.5), over twice as long as VRC01 (15 days). CONCLUSIONS: VRC07-523LS was safe and well tolerated across a range of doses and routes and is a promising long-acting bnAb for inclusion in HIV-1 prevention regimens. TRIAL REGISTRATION: ClinicalTrials.gov/ NCT03387150 (posted on 21 December 2017).


Asunto(s)
Anticuerpos Neutralizantes , Anticuerpos Anti-VIH , Humanos , Masculino , Femenino , Adulto , Anticuerpos Neutralizantes/sangre , Anticuerpos Anti-VIH/sangre , Persona de Mediana Edad , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/inmunología , VIH-1/inmunología , Adulto Joven , Anticuerpos ampliamente neutralizantes/administración & dosificación , Anticuerpos ampliamente neutralizantes/efectos adversos , Adolescente , Inyecciones Intramusculares
9.
J Acquir Immune Defic Syndr ; 96(4): 350-360, 2024 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-38916429

RESUMEN

BACKGROUND: An effective vaccine is required to end the HIV pandemic. We evaluated the safety and immunogenicity of a DNA (DNA-HIV-PT123) vaccine with low- or high-dose bivalent (TV1.C and 1086.C glycoprotein 120) subtype C envelope protein combinations, adjuvanted with MF59 or AS01B. METHODS: HIV Vaccine Trials Network (HVTN)108 was a randomized, placebo-controlled, double-blind, phase 1/2a trial conducted in the United States and South Africa. HIV-negative adults were randomly assigned to 1 of 7 intervention arms or placebo to assess DNA prime with DNA/protein/adjuvant boosts, DNA/protein/adjuvant co-administration, and low-dose protein/adjuvant regimens. HVTN111 trial participants who received an identical regimen were also included. Outcomes included safety and immunogenicity 2 weeks and 6 months after final vaccination. RESULTS: From June 2016 to July 2018, 400 participants were enrolled (N = 334 HVTN108, N = 66 HVTN111); 370 received vaccine and 30 received placebo. There were 48 grade 3 and 3 grade 4 reactogenicity events among 39/400 (9.8%) participants, and 32 mild/moderate-related adverse events in 23/400 (5.8%) participants. All intervention groups demonstrated high IgG response rates (>89%) and high magnitudes to HIV-1 Env gp120 and gp140 proteins; response rates for AS01B-adjuvanted groups approached 100%. V1V2 IgG magnitude, Fc-mediated functions, IgG3 Env response rates, and CD4+ T-cell response magnitudes and rates were higher in the AS01B-adjuvanted groups. The AS01B-adjuvanted low-dose protein elicited greater IgG responses than the higher protein dose. CONCLUSIONS: The vaccine regimens were generally well tolerated. Co-administration of DNA with AS01B-adjuvanted bivalent Env gp120 elicited the strongest humoral responses; AS01B-adjuvanted regimens elicited stronger CD4+ T-cell responses, justifying further evaluation.ClinicalTrials.gov registration: NCT02915016, registered 26 September 2016.


Asunto(s)
Vacunas contra el SIDA , Adyuvantes Inmunológicos , Anticuerpos Anti-VIH , Proteína gp120 de Envoltorio del VIH , Infecciones por VIH , VIH-1 , Polisorbatos , Escualeno , Vacunas de ADN , Humanos , Vacunas contra el SIDA/inmunología , Vacunas contra el SIDA/administración & dosificación , Vacunas contra el SIDA/efectos adversos , Vacunas de ADN/inmunología , Vacunas de ADN/administración & dosificación , Vacunas de ADN/efectos adversos , Femenino , Masculino , Adulto , Escualeno/administración & dosificación , Polisorbatos/administración & dosificación , Proteína gp120 de Envoltorio del VIH/inmunología , Adyuvantes Inmunológicos/administración & dosificación , VIH-1/inmunología , Infecciones por VIH/inmunología , Infecciones por VIH/prevención & control , Anticuerpos Anti-VIH/sangre , Método Doble Ciego , Persona de Mediana Edad , Adulto Joven , Adyuvantes de Vacunas/administración & dosificación , Sudáfrica , Inmunogenicidad Vacunal , Adolescente , Estados Unidos
10.
Front Immunol ; 15: 1347926, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38903517

RESUMEN

Introduction: The HVTN 105 vaccine clinical trial tested four combinations of two immunogens - the DNA vaccine DNA-HIV-PT123, and the protein vaccine AIDSVAX B/E. All combinations induced substantial antibody and CD4+ T cell responses in many participants. We have now re-examined the intracellular cytokine staining flow cytometry data using the high-resolution SWIFT clustering algorithm, which is very effective for enumerating rare populations such as antigen-responsive T cells, and also determined correlations between the antibody and T cell responses. Methods: Flow cytometry samples across all the analysis batches were registered using the swiftReg registration tool, which reduces batch variation without compromising biological variation. Registered data were clustered using the SWIFT algorithm, and cluster template competition was used to identify clusters of antigen-responsive T cells and to separate these from constitutive cytokine producing cell clusters. Results: Registration strongly reduced batch variation among batches analyzed across several months. This in-depth clustering analysis identified a greater proportion of responders than the original analysis. A subset of antigen-responsive clusters producing IL-21 was identified. The cytokine patterns in each vaccine group were related to the type of vaccine - protein antigens tended to induce more cells producing IL-2 but not IFN-γ, whereas DNA vaccines tended to induce more IL-2+ IFN-γ+ CD4 T cells. Several significant correlations were identified between specific antibody responses and antigen-responsive T cell clusters. The best correlations were not necessarily observed with the strongest antibody or T cell responses. Conclusion: In the complex HVTN105 dataset, alternative analysis methods increased sensitivity of the detection of antigen-specific T cells; increased the number of identified vaccine responders; identified a small IL-21-producing T cell population; and demonstrated significant correlations between specific T cell populations and serum antibody responses. Multiple analysis strategies may be valuable for extracting the most information from large, complex studies.


Asunto(s)
Vacunas contra el SIDA , Linfocitos T CD4-Positivos , Citocinas , Citometría de Flujo , Infecciones por VIH , Humanos , Vacunas contra el SIDA/inmunología , Linfocitos T CD4-Positivos/inmunología , Citometría de Flujo/métodos , Análisis por Conglomerados , Infecciones por VIH/inmunología , Infecciones por VIH/virología , Citocinas/metabolismo , Citocinas/inmunología , Inmunidad Humoral , Anticuerpos Anti-VIH/inmunología , Anticuerpos Anti-VIH/sangre , VIH-1/inmunología , Vacunas de ADN/inmunología , Interleucinas/inmunología
11.
J Med Virol ; 96(6): e29749, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38888113

RESUMEN

Human immunodeficiency virus (HIV) infection is still a global public health issue, and the development of an effective prophylactic vaccine inducing potent neutralizing antibodies remains a significant challenge. This study aims to explore the inflammation-related proteins associated with the neutralizing antibodies induced by the DNA/rTV vaccine. In this study, we employed the Olink chip to analyze the inflammation-related proteins in plasma in healthy individuals receiving HIV candidate vaccine (DNA priming and recombinant vaccinia virus rTV boosting) and compared the differences between neutralizing antibody-positive (nab + ) and -negative(nab-) groups. We identified 25 differentially expressed factors and conducted enrichment and correlation analysis on them. Our results revealed that significant expression differences in artemin (ARTN) and C-C motif chemokine ligand 23 (CCL23) between nab+ and -nab- groups. Notably, the expression of CCL23 was negatively corelated to the ID50 of neutralizing antibodies and the intensity of the CD4+ T cell responses. This study enriches our understanding of the immune picture induced by the DNA/rTV vaccine, and provides insights for future HIV vaccine development.


Asunto(s)
Vacunas contra el SIDA , Anticuerpos Neutralizantes , Anticuerpos Anti-VIH , Infecciones por VIH , VIH-1 , Proteómica , Virus Vaccinia , Humanos , Anticuerpos Neutralizantes/sangre , Anticuerpos Neutralizantes/inmunología , Virus Vaccinia/inmunología , Virus Vaccinia/genética , Anticuerpos Anti-VIH/sangre , Anticuerpos Anti-VIH/inmunología , VIH-1/inmunología , VIH-1/genética , Adulto , Vacunas contra el SIDA/inmunología , Masculino , Infecciones por VIH/inmunología , Vacunas de ADN/inmunología , Femenino , Voluntarios Sanos , Vacunas Sintéticas/inmunología , Vacunas Sintéticas/administración & dosificación , Plasma/inmunología , Adulto Joven
12.
BMC Res Notes ; 17(1): 153, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38835056

RESUMEN

OBJECTIVE: Fourth-generation HIV Ag/Ab Combo assay is used for HIV screening of blood for transfusion in developing countries, however, the sensitivity of the assay is questionable during the acute phase of HIV infection. Thus, the study aimed to determine the effect of combining centrifugation with HIV-1 virion lysis on the sensitivity of the fourth-generation HIV Ag/Ab combo assay. RESULTS: When the 50 HIV-1 antibody-negative samples were run on the fourth-generation HIV Ag/Ab combo assay, 8 (16%) were positive following centrifugation, 13 (26%) were positive following lysis while 25 (50%) were positive after combining centrifugation with HIV-1 virion lysis.


Asunto(s)
Centrifugación , Anticuerpos Anti-VIH , Infecciones por VIH , VIH-1 , Sensibilidad y Especificidad , Virión , VIH-1/inmunología , VIH-1/fisiología , Humanos , Centrifugación/métodos , Infecciones por VIH/diagnóstico , Infecciones por VIH/virología , Infecciones por VIH/inmunología , Infecciones por VIH/sangre , Anticuerpos Anti-VIH/sangre , Anticuerpos Anti-VIH/inmunología , Virión/aislamiento & purificación , Virión/inmunología , Antígenos VIH/inmunología , Antígenos VIH/sangre
13.
Lancet HIV ; 11(5): e285-e299, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38692824

RESUMEN

BACKGROUND: An effective HIV vaccine will most likely need to have potent immunogenicity and broad cross-subtype coverage. The aim of the HIV Vaccine Trials Network (HVTN) 124 was to evaluate safety and immunogenicity of a unique polyvalent DNA-protein HIV vaccine with matching envelope (Env) immunogens. METHODS: HVTN 124 was a randomised, phase 1, placebo-controlled, double-blind study, including participants who were HIV seronegative and aged 18-50 years at low risk for infection. The DNA vaccine comprised five plasmids: four copies expressing Env gp120 (clades A, B, C, and AE) and one gag p55 (clade C). The protein vaccine included four DNA vaccine-matched GLA-SE-adjuvanted recombinant gp120 proteins. Participants were enrolled across six clinical sites in the USA and were randomly assigned to placebo or one of two vaccine groups (ie, prime-boost or coadministration) in a 5:1 ratio in part A and a 7:1 ratio in part B. Vaccines were delivered via intramuscular needle injection. The primary outcomes were safety and tolerability, assessed via frequency, severity, and attributability of local and systemic reactogenicity and adverse events, laboratory safety measures, and early discontinuations. Part A evaluated safety. Part B evaluated safety and immunogenicity of two regimens: DNA prime (administered at months 0, 1, and 3) with protein boost (months 6 and 8), and DNA-protein coadministration (months 0, 1, 3, 6, and 8). All randomly assigned participants who received at least one dose were included in the safety analysis. The study is registered with ClinicalTrials.gov (NCT03409276) and is closed to new participants. FINDINGS: Between April 19, 2018 and Feb 13, 2019, 60 participants (12 in part A [five men and seven women] and 48 in part B [21 men and 27 women]) were enrolled. All 60 participants received at least one dose, and 14 did not complete follow-up (six of 21 in the prime-boost group and eight of 21 in the coadminstration group). 11 clinical adverse events deemed by investigators as study-related occurred in seven of 48 participants in part B (eight of 21 in the prime-boost group and three of 21 in the coadministration group). Local reactogenicity in the vaccine groups was common, but the frequency and severity of reactogenicity signs or symptoms did not differ between the prime-boost and coadministration groups (eg, 20 [95%] of 21 in the prime-boost group vs 21 [100%] of 21 in the coadministration group had either local pain or tenderness of any severity [p=1·00], and seven [33%] vs nine [43%] had either erythema or induration [p=0·97]), nor did laboratory safety measures. There were no delayed-type hypersensitivity reactions or vasculitis or any severe clinical adverse events related to vaccination. The most frequently reported systemic reactogenicity symptoms in the active vaccine groups were malaise or fatigue (five [50%] of ten in part A and 17 [81%] of 21 in the prime-boost group vs 15 [71%] of 21 in the coadministration group in part B), headache (five [50%] and 18 [86%] vs 12 [57%]), and myalgia (four [40%] and 13 [62%] vs ten [48%]), mostly of mild or moderate severity. INTERPRETATION: Both vaccine regimens were safe, warranting evaluation in larger trials. FUNDING: US National Institutes of Health and US National Institute of Allergy and Infectious Diseases.


Asunto(s)
Vacunas contra el SIDA , Anticuerpos Anti-VIH , Infecciones por VIH , VIH-1 , Vacunas de ADN , Humanos , Vacunas contra el SIDA/administración & dosificación , Vacunas contra el SIDA/inmunología , Vacunas contra el SIDA/efectos adversos , Adulto , Masculino , Femenino , Método Doble Ciego , Vacunas de ADN/administración & dosificación , Vacunas de ADN/inmunología , Vacunas de ADN/efectos adversos , Infecciones por VIH/prevención & control , Infecciones por VIH/inmunología , Persona de Mediana Edad , Adulto Joven , Anticuerpos Anti-VIH/sangre , Adolescente , VIH-1/inmunología , Estados Unidos , Inmunización Secundaria , Inmunogenicidad Vacunal , Proteína gp120 de Envoltorio del VIH/inmunología , Proteína gp120 de Envoltorio del VIH/genética , Anticuerpos Neutralizantes/sangre
14.
Lancet HIV ; 11(6): e389-e405, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38816141

RESUMEN

BACKGROUND: Allogeneic haematopoietic stem-cell transplantation (allo-HSCT) markedly reduces HIV reservoirs, but the mechanisms by which this occurs are only partly understood. In this study, we aimed to describe the dynamics of virological and immunological markers of HIV persistence after allo-HSCT. METHODS: In this prospective observational cohort study, we analysed the viral reservoir and serological dynamics in IciStem cohort participants with HIV who had undergone allo-HSCT and were receiving antiretroviral therapy, ten of whom had received cells from donors with the CCR5Δ32 mutation. Participants from Belgium, Canada, Germany, Italy, the Netherlands, Spain, Switzerland, and the UK were included in the cohort both prospectively and retrospectively between June 1, 2014 and April 30, 2019. In the first 6 months after allo-HSCT, participants had monthly assessments, with annual assessments thereafter, with the protocol tailored to accommodate for the individual health status of each participant. HIV reservoirs were measured in blood and tissues and HIV-specific antibodies were measured in plasma. We used the Wilcoxon signed-rank test to compare data collected before and after allo-HSCT in participants for whom longitudinal data were available. When the paired test was not possible, we used the Mann-Whitney U test. We developed a mathematical model to study the factors influencing HIV reservoir reduction in people with HIV after allo-HSCT. FINDINGS: We included 30 people with HIV with haematological malignancies who received a transplant between Sept 1, 2009 and April 30, 2019 and were enrolled within the IciStem cohort and included in this analysis. HIV reservoirs in peripheral blood were reduced immediately after full donor chimerism was achieved, generally accompanied by undetectable HIV-DNA in bone marrow, ileum, lymph nodes, and cerebrospinal fluid, regardless of donor CCR5 genotype. HIV-specific antibody levels and functionality values declined more slowly than direct HIV reservoir values, decaying significantly only months after full donor chimerism. Mathematical modelling suggests that allogeneic immunity mediated by donor cells is the main viral reservoir depletion mechanism after massive reservoir reduction during conditioning chemotherapy before allo-HSCT (half-life of latently infected replication-competent cells decreased from 44 months to 1·5 months). INTERPRETATION: Our work provides, for the first time, data on the effects of allo-HSCT in the context of HIV infection. Additionally, we raise the question of which marker can serve as the last reporter of the residual viraemia, postulating that the absence of T-cell immune responses might be a more reliable marker than antibody decline after allo-HSCT. FUNDING: amfAR (American Foundation for AIDS Research; ARCHE Program), National Institutes of Health, National Institute of Allergy and Infectious Diseases, and Dutch Aidsfonds.


Asunto(s)
Infecciones por VIH , Trasplante de Células Madre Hematopoyéticas , Humanos , Trasplante de Células Madre Hematopoyéticas/efectos adversos , Infecciones por VIH/inmunología , Infecciones por VIH/virología , Masculino , Estudios Prospectivos , Femenino , Adulto , Persona de Mediana Edad , VIH-1/inmunología , Trasplante Homólogo , Biomarcadores/sangre , Carga Viral , Anticuerpos Anti-VIH/sangre
16.
J Infect Dis ; 229(6): 1919-1925, 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38451247

RESUMEN

Current serologic tests for HIV screening and confirmation of infection present challenges to the adoption of HIV vaccines. The detection of vaccine-induced HIV-1 antibodies in the absence of HIV-1 infection, referred to as vaccine-induced seropositivity/seroreactivity, confounds the interpretation of test results, causing misclassification of HIV-1 status with potential affiliated stigmatization. For HIV vaccines to be widely adopted with high community confidence and uptake, tests are needed that are agnostic to the vaccination status of tested individuals (ie, positive only for true HIV-1 infection). Successful development and deployment of such tests will require HIV vaccine developers to work in concert with diagnostic developers. Such tests will need to match today's high-performance standards (accuracy, cost-effectiveness, simplicity) for use in vaccinated and unvaccinated populations, especially in low- and middle-income countries with high HIV burden. Herein, we discuss the challenges and strategies for developing modified serologic HIV tests for concurrent deployment with HIV vaccines.


Asunto(s)
Vacunas contra el SIDA , Infecciones por VIH , VIH-1 , Humanos , Infecciones por VIH/diagnóstico , Infecciones por VIH/prevención & control , Vacunas contra el SIDA/inmunología , VIH-1/inmunología , Anticuerpos Anti-VIH/sangre , Anticuerpos Anti-VIH/inmunología , Pruebas Serológicas/métodos
17.
AIDS ; 38(8): 1181-1185, 2024 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-38489581

RESUMEN

OBJECTIVE: The aim of this study was to examine outcomes of follow-up for persons with discordant fourth-generation HIV screening test results. DESIGN: A retrospective chart review. METHODS: We analyzed the electronic health record at the Medical University of South Carolina for a 10-year period spanning 2012-2022 to identify instances of discordant HIV screening test results, wherein initial antigen/antibody screening was positive, but reflex confirmatory testing for HIV-1 and HIV-2 antibodies was negative. We reviewed individual records to evaluate clinical follow-up and determine if the discordant test represented an acute HIV infection, a false-positive result, or was unresolved. RESULTS: We identified 199 testing instances with discordant results. Most discordant results ( n  = 115) were subsequently determined to reflect a false-positive test, while 56 were unresolved without documented follow-up testing. Twenty-eight cases of acute HIV infection were identified of which 26 were linked to care within a month of initial testing. Two acute HIV cases were not identified in real time leading to delay in diagnosis and care. Testing done in the context of infectious symptoms and testing performed in the emergency department were associated with increased odds of a discordant test ultimately reflecting acute HIV infection. CONCLUSION: These results demonstrate the importance of appropriate and timely follow-up for discordant HIV screening test results.


Asunto(s)
Centros Médicos Académicos , Infecciones por VIH , Prueba de VIH , Humanos , Estudios Retrospectivos , Infecciones por VIH/diagnóstico , Masculino , Femenino , Adulto , Prueba de VIH/estadística & datos numéricos , Persona de Mediana Edad , South Carolina , Adulto Joven , Tamizaje Masivo/métodos , Anticuerpos Anti-VIH/sangre , Anciano , Adolescente , VIH-1/aislamiento & purificación , VIH-1/inmunología , VIH-2/inmunología
18.
J Infect Chemother ; 30(9): 917-921, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38331251

RESUMEN

Seronegative human immunodeficiency virus (HIV) infection, where an HIV-specific antibody response is lacking even in chronic or late-stage HIV infections, is extremely rare. Here, we report the case of a 50-year-old Japanese man presenting with Pneumocystis pneumonia who did not produce antibodies against HIV-1 until the initiation of antiretroviral therapy (ART). Fourth-generation antigen-antibody testing temporarily reverted from weakly positive to negative soon after initiating ART, likely due to a reduction in viral load (assessed by p24 antigen levels). His HIV-1 antibody titers remained low or indeterminate even after four years of ART. A literature review suggested that the absence of HIV-1-specific antibody production may be associated with unimpeded HIV replication and rapid CD4+ T cell decline. Seronegative HIV infection can lead to deferred diagnosis and treatment, thereby increasing the risk of transmitting the virus to others or developing opportunistic illnesses. It is important to combine multiple tests for diagnosis, depending on the medical condition. Further studies are required to investigate the host factors involved in the production of HIV-1-specific antibodies.


Asunto(s)
Infecciones por VIH , VIH-1 , Neumonía por Pneumocystis , Humanos , Masculino , Neumonía por Pneumocystis/diagnóstico , Neumonía por Pneumocystis/inmunología , Neumonía por Pneumocystis/microbiología , Persona de Mediana Edad , VIH-1/inmunología , Infecciones por VIH/complicaciones , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/inmunología , Anticuerpos Anti-VIH/sangre , Anticuerpos Anti-VIH/inmunología , Carga Viral , Infecciones Oportunistas Relacionadas con el SIDA/diagnóstico , Infecciones Oportunistas Relacionadas con el SIDA/inmunología , Infecciones Oportunistas Relacionadas con el SIDA/microbiología , Seronegatividad para VIH , Formación de Anticuerpos , Pneumocystis carinii/aislamiento & purificación , Pneumocystis carinii/inmunología , Pueblos del Este de Asia
19.
J Virol ; 97(1): e0163822, 2023 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-36511698

RESUMEN

Small CD4-mimetic compound (CD4mc), which inhibits the interaction between gp120 with CD4, acts as an entry inhibitor and induces structural changes in the HIV-1 envelope glycoprotein trimer (Env) through its insertion within the Phe43 cavity of gp120. We recently developed YIR-821, a novel CD4mc, that has potent antiviral activity and lower toxicity than the prototype NBD-556. To assess the possibility of clinical application of YIR-821, we tested its antiviral activity using a panel of HIV-1 pseudoviruses from different subtypes. YIR-821 displayed entry inhibitor activity against 53.5% (21/40) of the pseudoviruses tested and enhanced neutralization mediated by coreceptor binding site (CoRBS) antibodies in 50% (16/32) of these. Furthermore, when we assessed the antiviral effects using a panel of pseudoviruses and autologous plasma IgG, enhancement of antibody-mediated neutralization activity was observed for 48% (15/31) of subtype B strains and 51% (28/55) of non-B strains. The direct antiviral activity of YIR-821 as an entry inhibitor was observed in 53% of both subtype B (27/51) and non-B subtype (40/75) pseudoviruses. Enhancement of antibody-dependent cellular cytotoxicity was also observed with YIR-821 for all six selected clinical isolates, as well as for the transmitted/founder (T/F) CH58 virus-infected cells. The sequence diversity in the CD4 binding site as well as other regions, such as the gp120 inner domain layers or gp41, may be involved in the multiple mechanisms related to the sensitive/resistant phenotype of the virus to YIR-821. Our findings may facilitate the clinical application of YIR-821. IMPORTANCE Small CD4-mimetic compound (CD4mc) interacts with the Phe43 cavity and triggers conformational changes, enhancing antibody-mediated neutralization and antibody-dependent cellular cytotoxicity (ADCC). Here, we evaluated the effect of YIR-821, a novel CD4mc, against clinical isolates, including both subtype B and non-B subtype viruses. Our results confirm the desirable properties of YIR-821, which include entry inhibition, enhancement of IgG-neutralization, binding, and ADCC, in addition to low toxicity and long half-life in a rhesus macaque model, that might facilitate the clinical application of this novel CD4mc. Our observation of primary viruses that are resistant to YIR-821 suggests that further development of CD4mcs with different structural properties is required.


Asunto(s)
Inhibidores de Fusión de VIH , Infecciones por VIH , VIH-1 , Animales , Antígenos CD4/metabolismo , Anticuerpos Anti-VIH/sangre , Proteína gp120 de Envoltorio del VIH , Inhibidores de Fusión de VIH/farmacología , Infecciones por VIH/tratamiento farmacológico , VIH-1/efectos de los fármacos , Inmunoglobulina G/sangre , Macaca mulatta
20.
Front Immunol ; 13: 840976, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35572573

RESUMEN

A better understanding of the impact of early innate immune responses after vaccine priming on vaccine-elicited adaptive immune responses could inform rational design for effective HIV vaccines. The current study compared the whole blood molecular immune signatures of a 3M-052-SE adjuvanted HIV Env protein vaccine to a regimen combining the adjuvanted Env protein with simultaneous administration of a modified Vaccinia Ankara vector expressing HIV Env in infant rhesus macaques at days 0, 1, and 3 post vaccine prime. Both vaccines induced a rapid innate response, evident by elevated inflammatory plasma cytokines and altered gene expression. We identified 25 differentially-expressed genes (DEG) on day 1 compared to day 0 in the HIV protein vaccine group. In contrast, in the group that received both the Env protein and the MVA-Env vaccine only two DEG were identified, implying that the MVA-Env modified the innate response to the adjuvanted protein vaccine. By day 3, only three DEG maintained altered expression, indicative of the transient nature of the innate response. The DEG represented immune pathways associated with complement activation, type I interferon and interleukin signaling, pathogen sensing, and induction of adaptive immunity. DEG expression on day 1 was correlated to Env-specific antibody responses, in particular antibody-dependent cytotoxicity responses at week 34, and Env-specific follicular T helper cells. Results from network analysis supported the interaction of DEG and their proteins in B cell activation. These results emphasize that vaccine-induced HIV-specific antibody responses can be optimized through the modulation of the innate response to the vaccine prime.


Asunto(s)
Vacunas contra el SIDA , Anticuerpos Anti-VIH/sangre , Infecciones por VIH , Proteínas del Envoltorio Viral/inmunología , Adyuvantes Inmunológicos/farmacología , Animales , Productos del Gen env , Anticuerpos Anti-VIH/inmunología , Infecciones por VIH/prevención & control , Humanos , Macaca mulatta , Vacunación , Virus Vaccinia/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...