Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Thorac Cardiovasc Surg ; 155(1): 147-155, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29074049

RESUMEN

OBJECTIVE: Previously, cardiac surgeons and cardiologists learned to operate new clinical devices for the first time in the operating room or catheterization laboratory. We describe a biosimulator that recapitulates normal heart valve physiology with associated real-time hemodynamic performance. METHODS: To highlight the advantages of this simulation platform, transventricular extruded polytetrafluoroethylene artificial chordae were attached to repair flail or prolapsing mitral valve leaflets. Guidance for key repair steps was by 2-dimensional/3-dimensional echocardiography and simultaneous intracardiac videoscopy. RESULTS: Multiple surgeons have assessed the use of this biosimulator during artificial chordae implantations. This simulation platform recapitulates normal and pathologic mitral valve function with associated hemodynamic changes. Clinical situations were replicated in the simulator and echocardiography was used for navigation, followed by videoscopic confirmation. CONCLUSIONS: This beating heart biosimulator reproduces prolapsing mitral leaflet pathology. It may be the ideal platform for surgeon and cardiologist training on many transcatheter and beating heart procedures.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral/cirugía , Entrenamiento Simulado/métodos , Cardiología/educación , Cirugía General/educación , Humanos , Anuloplastia de la Válvula Mitral/educación , Anuloplastia de la Válvula Mitral/métodos
2.
Innovations (Phila) ; 12(6): 459-465, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29232300

RESUMEN

OBJECTIVE: As the use of minimally invasive surgery in cardiothoracic surgery increases, so does the need for simulation and training. We developed a heart model for simulation and training of minimally invasive cardiac surgery, particularly minimally invasive mitral valve repair using our new three-dimensional printing system. METHODS: Digital imaging and communication in medicine data from patient computed tomography, three-dimensional computer-aided design, and three-dimensional printing helped create replicas of the heart and thoracic cavity. A polyvinyl alcohol model material with a texture and physical properties similar to those of heart tissue was initially used in mitral valve replicas to simulate surgical procedures. To develop this material, we mechanically investigated the composition of each part of the porcine heart. RESULTS: We investigated the elastic modulus and breaking strength of the porcine heart. Based on investigation results, the cardiac model was set at rupture strength 20 MPa, elastic modulus 0.17 MPa, and moisture content 85%. This provided a biotexture and feeling exactly like a patient heart. Computed tomography scans confirmed that the model shape was nearly the same as that of a human heart. We simulated minimally invasive mitral valve repair, including ring annuloplasty, chordal reconstruction, resection and suture, and edge-to-edge repair. Full surgery simulations using this model used minimally invasive cardiac surgery tools including a robot. CONCLUSIONS: This life-like model can be used as a standard simulator to train younger, less experienced surgeons to practice minimally invasive cardiac surgery procedures and may help develop new operative tools.


Asunto(s)
Procedimientos Quirúrgicos Mínimamente Invasivos/educación , Anuloplastia de la Válvula Mitral/educación , Válvula Mitral/cirugía , Modelos Anatómicos , Impresión Tridimensional , Entrenamiento Simulado/métodos , Animales , Procedimientos Quirúrgicos Cardíacos/educación , Diseño Asistido por Computadora , Módulo de Elasticidad , Alcohol Polivinílico , Porcinos , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...