Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.350
Filtrar
2.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38848447

RESUMEN

Pulsed field ablation (PFA) is an innovative approach in the field of cardiac electrophysiology aimed at treating cardiac arrhythmias. Unlike traditional catheter ablation energies, which use radiofrequency or cryothermal energy to create lesions in the heart, PFA utilizes pulsed electric fields to induce irreversible electroporation, leading to targeted tissue destruction. This state-of-the-art review summarizes biophysical principles and clinical applications of PFA, highlighting its potential advantages over conventional ablation methods. Clinical data of contemporary PFA devices are discussed, which combine predictable procedural outcomes and a reduced risk of thermal collateral damage. Overall, these technological developments have propelled the rapid evolution of contemporary PFA catheters, with future advancements potentially impacting patient care.


Asunto(s)
Arritmias Cardíacas , Humanos , Arritmias Cardíacas/cirugía , Arritmias Cardíacas/terapia , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico , Electroporación/tendencias , Electroporación/métodos , Resultado del Tratamiento , Predicción , Ablación por Catéter/tendencias , Ablación por Catéter/métodos , Técnicas de Ablación/tendencias , Catéteres Cardíacos , Animales
3.
Comput Methods Programs Biomed ; 253: 108239, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38823116

RESUMEN

BACKGROUND: The excitable gap (EG), defined as the excitable tissue between two subsequent wavefronts of depolarization, is critical for maintaining reentry that underlies deadly ventricular arrhythmias. EG in the His-Purkinje Network (HPN) plays an important role in the maintenance of electrical wave reentry that underlies these arrhythmias. OBJECTIVE: To determine if rapid His bundle pacing (HBP) during reentry reduces the amount of EG in the HPN and ventricular myocardium to suppress reentry maintenance and/or improve defibrillation efficacy. METHODS: In a virtual human biventricular model, reentry was initiated with rapid line pacing followed by HBP delivered for 3, 6, or 9 s at pacing cycle lengths (PCLs) ranging from 10 to 300 ms (n=30). EG was calculated independently for the HPN and myocardium over each PCL. Defibrillation efficacy was assessed for each PCL by stimulating myocardial surface EG with delays ranging from 0.25 to 9 s (increments of 0.25 s, n=36) after the start of HBP. Defibrillation was successful if reentry terminated within 1 s after EG stimulation. This defibrillation protocol was repeated without HBP. To test the approach under different pathological conditions, all protocols were repeated in the model with right (RBBB) or left (LBBB) bundle branch block. RESULTS: Compared to without pacing, HBP for >3 seconds reduced average EG in the HPN and myocardium across a broad range of PCLs for the default, RBBB, and LBBB models. HBP >6 seconds terminated reentrant arrhythmia by converting HPN activation to a sinus rhythm behavior in the default (6/30 PCLs) and RBBB (7/30 PCLs) models. Myocardial EG stimulation during HBP increased the number of successful defibrillation attempts by 3%-19% for 30/30 PCLs in the default model, 3%-6% for 14/30 PCLs in the RBBB model, and 3%-11% for 27/30 PCLs in the LBBB model. CONCLUSION: HBP can reduce the amount of excitable gap and suppress reentry maintenance in the HPN and myocardium. HBP can also improve the efficacy of low-energy defibrillation approaches targeting excitable myocardium. HBP during reentrant arrhythmias is a promising anti-arrhythmic and defibrillation strategy.


Asunto(s)
Fascículo Atrioventricular , Humanos , Fascículo Atrioventricular/fisiopatología , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/métodos , Cardioversión Eléctrica/métodos , Ventrículos Cardíacos/fisiopatología , Modelos Cardiovasculares
4.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38866455

RESUMEN

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estimulación Cardíaca Artificial , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Factores de Riesgo , Anciano , Factores de Tiempo , Anciano de 80 o más Años , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/mortalidad , Estados Unidos/epidemiología
6.
Medicina (Kaunas) ; 60(5)2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38793002

RESUMEN

Over the past decade, remote monitoring (RM) has become an increasingly popular way to improve healthcare and health outcomes. Modern cardiac implantable electronic devices (CIEDs) are capable of recording an increasing amount of data related to CIED function, arrhythmias, physiological status and hemodynamic parameters, providing in-depth and updated information on patient cardiovascular function. The extensive use of RM for patients with CIED allows for early diagnosis and rapid assessment of relevant issues, both clinical and technical, as well as replacing outpatient follow-up improving overall management without compromise safety. This approach is recommended by current guidelines for all eligible patients affected by different chronic cardiac conditions including either brady- and tachy-arrhythmias and heart failure. Beyond to clinical advantages, RM has demonstrated cost-effectiveness and is associated with elevated levels of patient satisfaction. Future perspectives include improving security, interoperability and diagnostic power as well as to engage patients with digital health technology. This review aims to update existing data concerning clinical outcomes in patients managed with RM in the wide spectrum of cardiac arrhythmias and Hear Failure (HF), disclosing also about safety, effectiveness, patient satisfaction and cost-saving.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Monitoreo Fisiológico/métodos , Telemedicina/tendencias , Desfibriladores Implantables/normas
7.
J Am Coll Cardiol ; 83(22): 2214-2232, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38811098

RESUMEN

Arrhythmias frequently accompany heart failure and left ventricular dysfunction. Tachycardias, atrial fibrillation, and premature ventricular contractions can induce a reversible form of dilated cardiomyopathy (CM) known as arrhythmia-induced CM (AiCM). The intriguing question is why certain individuals are more susceptible to AiCM, despite similar arrhythmia burdens. The primary challenge is determining the extent of arrhythmias' contribution to left ventricular systolic dysfunction. AiCM should be considered in patients with a mean heart rate of >100 beats/min, atrial fibrillation, or a PVC burden of >10%. Confirmation of AiCM occurs when CM reverses upon eliminating the responsible arrhythmia. Therapy choice depends on the specific arrhythmia, patient comorbidities, and preferences. After left ventricular function is restored, ongoing follow-up is essential if an abnormal myocardial substrate persists. Accurate diagnosis and treatment of AiCM have the potential to enhance patients' quality of life, improve clinical outcomes, and reduce hospital admissions and overall health care costs.


Asunto(s)
Arritmias Cardíacas , Humanos , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Arritmias Cardíacas/fisiopatología , Cardiomiopatías/etiología , Cardiomiopatías/terapia , Cardiomiopatías/fisiopatología , Cardiomiopatías/diagnóstico , Cardiomiopatía Dilatada/terapia , Cardiomiopatía Dilatada/fisiopatología , Cardiomiopatía Dilatada/etiología
11.
J Am Heart Assoc ; 13(11): e031632, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38804208

RESUMEN

BACKGROUND: Pregnancy in patients with pulmonary hypertension (PH) is associated with a heightened risk of medical complications including right heart failure, pulmonary edema, and arrhythmias. Our study investigated the association between PH and these complications during delivery. METHODS AND RESULTS: The National Inpatient Sample was used to identify delivery hospitalizations from 2011 to 2020. Multivariable logistic regression was performed to study the association of PH with the primary outcomes of in-hospital medical and obstetric complications. A total of 37 482 207 delivery hospitalizations in women ≥18 years of age were identified, of which 9593 patients had PH. Pregnant patients with PH had higher incidence of complications during delivery including preeclampsia/eclampsia, arrhythmias, and pulmonary edema among others, compared with those without PH. Pregnant patients with PH also had a higher incidence of in-hospital mortality compared with those without PH (0.51% versus 0.007%). In propensity-matched analyses, PH was still significantly associated with a higher risk of in-hospital mortality (odds ratio [OR], 5.02 [95% CI, 1.82-13.90]; P=0.001), pulmonary edema (OR, 9.11 [95% CI, 6.34-13.10]; P<0.001), peripartum cardiomyopathy (OR, 1.85 [95% CI, 1.37-2.50]; P<0.001), venous thromboembolism (OR, 12.60 [95% CI, 6.04-26.10]; P<0.001), cardiac arrhythmias (OR, 6.11 [95% CI, 4.97-7.53]; P<0.001), acute kidney injury (OR, 3.72 [95% CI, 2.86-4.84]; P<0.001), preeclampsia/eclampsia (OR, 2.24 [95% CI, 1.95-2.58]; P<0.001), and acute coronary syndrome (OR, 2.01 [95% CI, 1.06-3.80]; P=0.03), compared with pregnant patients without PH. CONCLUSIONS: Delivery hospitalizations in patients with PH are associated with a high risk of mortality, pulmonary edema, peripartum cardiomyopathy, venous thromboembolism, arrhythmias, acute kidney injury, preeclampsia/eclampsia, and acute coronary syndrome.


Asunto(s)
Mortalidad Hospitalaria , Hospitalización , Hipertensión Pulmonar , Complicaciones Cardiovasculares del Embarazo , Humanos , Femenino , Embarazo , Hipertensión Pulmonar/epidemiología , Hipertensión Pulmonar/mortalidad , Hipertensión Pulmonar/terapia , Adulto , Estados Unidos/epidemiología , Hospitalización/estadística & datos numéricos , Hospitalización/tendencias , Complicaciones Cardiovasculares del Embarazo/epidemiología , Complicaciones Cardiovasculares del Embarazo/terapia , Mortalidad Hospitalaria/tendencias , Incidencia , Adulto Joven , Factores de Riesgo , Estudios Retrospectivos , Parto Obstétrico/estadística & datos numéricos , Parto Obstétrico/efectos adversos , Edema Pulmonar/epidemiología , Edema Pulmonar/etiología , Edema Pulmonar/mortalidad , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Arritmias Cardíacas/mortalidad , Medición de Riesgo
12.
J Am Heart Assoc ; 13(11): e032465, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38804218

RESUMEN

BACKGROUND: New methods to identify patients who benefit from a primary prophylactic implantable cardioverter-defibrillator (ICD) are needed. T-wave alternans (TWA) has been shown to associate with arrhythmogenesis of the heart and sudden cardiac death. We hypothesized that TWA might be associated with benefit from ICD implantation in primary prevention. METHODS AND RESULTS: In the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter-Defibrillators) study, we prospectively enrolled 2327 candidates for primary prophylactic ICD. A 24-hour Holter monitor reading was taken from all recruited patients at enrollment. TWA was assessed from Holter monitoring using the modified moving average method. Study outcomes were all-cause death, appropriate shock, and survival benefit. TWA was assessed both as a contiguous variable and as a dichotomized variable with cutoff points <47 µV and <60 µV. The final cohort included 1734 valid T-wave alternans samples, 1211 patients with ICD, and 523 control patients with conservative treatment, with a mean follow-up time of 2.3 years. TWA ≥60 µV was a predicter for a higher all-cause death in patients with an ICD on the basis of a univariate Cox regression model (hazard ratio, 1.484 [95% CI, 1.024-2.151]; P=0.0374; concordance statistic, 0.51). In multivariable models, TWA was not prognostic of death or appropriate shocks in patients with an ICD. In addition, TWA was not prognostic of death in control patients. In a propensity score-adjusted Cox regression model, TWA was not a predictor of ICD benefit. CONCLUSIONS: T-wave alternans is poorly prognostic in patients with a primary prophylactic ICD. Although it may be prognostic of life-threatening arrhythmias and sudden cardiac death in several patient populations, it does not seem to be useful in assessing benefit from ICD therapy in primary prevention among patients with an ejection fraction of ≤35%.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Electrocardiografía Ambulatoria , Prevención Primaria , Humanos , Prevención Primaria/métodos , Masculino , Femenino , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Electrocardiografía Ambulatoria/métodos , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Medición de Riesgo/métodos , Factores de Riesgo , Arritmias Cardíacas/terapia , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/prevención & control , Arritmias Cardíacas/mortalidad , Resultado del Tratamiento , Valor Predictivo de las Pruebas , Factores de Tiempo , Europa (Continente)/epidemiología , Pronóstico , Frecuencia Cardíaca/fisiología
14.
J Bodyw Mov Ther ; 38: 417-424, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38763587

RESUMEN

BACKGROUND: Heart disease is the leading cause of death in many countries around the world and is linked to numerous complications. In addition to conventional pharmacological treatments, complementary and alternative medicines like massage and dry cupping are employed to help manage the disease and its symptoms. This study aimed to compare the effects of massage and dry cupping on dysrhythmia in patients with heart diseases. METHODS: This randomized parallel controlled clinical trial study was conducted in two critical care units of Shafa hospital in Kerman, southeastern Iran, in 2019-2020. A total of 90 eligible patients were allocated into three groups: massage (n = 30), dry cupping (n = 30), and control (n = 30) using a stratified block randomization method. In the massage group, the head and face were massaged for three consecutive nights, while the dry cupping group received dry cupping between the fifth cervical vertebra and the second thoracic vertebra for the same duration. Each intervention session lasted 15 min. Data collection tools included a socio-demographic and clinical characteristics questionnaire, a form for hemodynamic parameters (systolic blood pressure, diastolic blood pressure, heart rate, respiratory rate, and peripheral oxygen saturation), and a form for assessing dysrhythmia using electrocardiogram readings. Dysrhythmia in the participants was evaluated after each session. RESULTS: The results within each group indicated a statistically significant difference in the prevalence of dysrhythmia in the dry cupping group after the intervention (P < 0.05), but this difference was not statistically significant in the massage and control groups. However, when comparing between the groups, no significant difference was found among the three groups. Additionally, there was no significant difference in the type of dysrhythmia between the groups (P > 0.05). CONCLUSION: While there was no difference in the type of dysrhythmia between the three groups, the additional reduction of dysrhythmia in the dry cupping group could hold clinical significance. Further studies are recommended to validate or refute the findings of the present study.


Asunto(s)
Arritmias Cardíacas , Masaje , Humanos , Masculino , Femenino , Persona de Mediana Edad , Masaje/métodos , Adulto , Arritmias Cardíacas/terapia , Frecuencia Cardíaca/fisiología , Ventosaterapia/métodos , Anciano , Cardiopatías , Irán , Presión Sanguínea/fisiología
15.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38696701

RESUMEN

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica , Puntaje de Propensión , Sistema de Registros , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Factores Sexuales , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Arritmias Cardíacas/terapia , Medición de Riesgo , Europa (Continente) , Factores de Tiempo , Muerte Súbita Cardíaca/prevención & control
16.
Medicine (Baltimore) ; 103(18): e37990, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38701276

RESUMEN

Brugada syndrome (BS) is characterized by ST segment elevation in right precordial leads (V1-V3), ventricular tachycardia (VT), ventricular fibrillation (VF), and sudden cardiac death (SCD) in individuals without structural heart disease. The aim of this study is to contribute to the controversial issue of finding the most valuable marker that can predict poor prognosis during follow-up in patients with a diagnosis of BS. A total of 68 patients diagnosed with BS or had Brugada-type ECG change between January 1997 and July 2012 at the Department of Cardiology of Baskent University Faculty of Medicine, Ankara, Turkey, were included in this cohort study. Patients were screened every 6 months for arrhythmia-related syncope, SCD, appropriate and inappropriate defibrillation (shock), AF development and death; collectively defined as "arrhythmic events" and were the primary endpoints. Patients with and without arrhythmic events were compared. The mean age was 34.9 ±â€…12.2 years (9-71 years), and 52 (76.5%) patients were male. Mean follow-up was 49.6 ±â€…37.6 months (4-188 months). Univariate analysis showed that male sex (P = .004), type 1 electrocardiographic pattern (P = .008), SCD (P = .036), VT/VF history (P = .046), requirement for electrophysiological studies (P = .034), implantable cardioverter-defibrillator placement (P = .014) were found to demonstrate significant differences in patients with and without arrhythmic events. In multivariable analyzes, spontaneous type 1 ECG presence (HR = 8.54, 95% CI: 0.38-26.37; P = .003) and VT/VF history (HR = 9.21, 95% CI: 0.004-1.88; P = .002) were found to be independently associated with arrhythmic events. We found the presence of spontaneous type 1 ECG and a history of VT/VF to be associated with increased likelihood of overall arrhythmic events in BS. Given the higher risk of poor prognosis, we recommend additional measures in patients with BS who have these features.


Asunto(s)
Síndrome de Brugada , Muerte Súbita Cardíaca , Electrocardiografía , Humanos , Síndrome de Brugada/terapia , Síndrome de Brugada/complicaciones , Síndrome de Brugada/fisiopatología , Masculino , Femenino , Adulto , Persona de Mediana Edad , Factores de Riesgo , Estudios de Seguimiento , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Adolescente , Adulto Joven , Anciano , Niño , Turquía/epidemiología , Pronóstico , Desfibriladores Implantables , Fibrilación Ventricular/terapia , Fibrilación Ventricular/etiología , Fibrilación Ventricular/complicaciones , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia
17.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38693772

RESUMEN

AIMS: Arrhythmia-induced cardiomyopathy (AiCM) represents a subtype of acute heart failure (HF) in the context of sustained arrhythmia. Clear definitions and management recommendations for AiCM are lacking. The European Heart Rhythm Association Scientific Initiatives Committee (EHRA SIC) conducted a survey to explore the current definitions and management of patients with AiCM among European and non-European electrophysiologists. METHODS AND RESULTS: A 25-item online questionnaire was developed and distributed among EP specialists on the EHRA SIC website and on social media between 4 September and 5 October 2023. Of the 206 respondents, 16% were female and 61% were between 30 and 49 years old. Most of the respondents were EP specialists (81%) working at university hospitals (47%). While most participants (67%) agreed that AiCM should be defined as a left ventricular ejection fraction (LVEF) impairment after new onset of an arrhythmia, only 35% identified a specific LVEF drop to diagnose AiCM with a wide range of values (5-20% LVEF drop). Most respondents considered all available therapies: catheter ablation (93%), electrical cardioversion (83%), antiarrhythmic drugs (76%), and adjuvant HF treatment (76%). A total of 83% of respondents indicated that adjuvant HF treatment should be started at first HF diagnosis prior to antiarrhythmic treatment, and 84% agreed it should be stopped within six months after LVEF normalization. Responses for the optimal time point for the first LVEF reassessment during follow-up varied markedly (1 day-6 months after antiarrhythmic treatment). CONCLUSION: This EHRA Survey reveals varying practices regarding AiCM among physicians, highlighting a lack of consensus and heterogenous care of these patients.


Asunto(s)
Arritmias Cardíacas , Cardiomiopatías , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Femenino , Masculino , Cardiomiopatías/terapia , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Persona de Mediana Edad , Adulto , Europa (Continente) , Encuestas y Cuestionarios , Volumen Sistólico , Encuestas de Atención de la Salud , Antiarrítmicos/uso terapéutico , Pautas de la Práctica en Medicina/estadística & datos numéricos , Función Ventricular Izquierda , Ablación por Catéter , Cardiólogos
19.
Ther Umsch ; 81(2): 54-59, 2024 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-38780211

RESUMEN

INTRODUCTION: Arrhythmias manifest frequently in individuals with heart failure, posing a notable threat of mortality and morbidity. While the prevention of sudden cardiac death through ICD therapy remains pivotal, accurate risk stratification remains a challenging task even in 2024. Recent data underscore the early consideration of catheter ablation for ventricular tachycardias. Although antiarrhythmic drug therapy serves as an ancillary measure for symptomatic patients, it does not confer prognostic advantages. The holistic management of arrhythmias in heart failure necessitates a systematic, multidimensional approach that initiates with evidence-based medical therapy for heart failure and integrates device-based and interventional therapies. Noteworthy clinical studies have illustrated the positive prognostic impact of early rhythm control strategies, particularly catheter ablation, in individuals managing heart failure and atrial fibrillation.


Asunto(s)
Ablación por Catéter , Insuficiencia Cardíaca , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico , Humanos , Ablación por Catéter/métodos , Antiarrítmicos/uso terapéutico , Desfibriladores Implantables , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Pronóstico , Terapia Combinada , Fibrilación Atrial/terapia , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/complicaciones , Medicina Basada en la Evidencia , Taquicardia Ventricular/terapia , Taquicardia Ventricular/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA