Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.761
Filtrar
1.
JBJS Case Connect ; 14(3)2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39146441

RESUMEN

CASE: (1) A 69-year-old man sustained a proximal humeral fracture-dislocation. During emergency surgery, copious bleeding occurred. A pseudoaneurysm was identified 30 days postoperatively. (2) A 69-year-old man sustained a proximal humeral fracture and axillary artery injury. Physical examination demonstrated a cold but pink hand. Hemiarthroplasty and bypass vein grafting were performed. (3) An 86-year-old woman sustained a proximal humeral fracture and axillary artery injury. Her hand had turned cold and pale. Reverse shoulder arthroplasty and bypass vein grafting were performed. CONCLUSION: In cases of proximal humeral fractures with significant displacement, concomitant axillary artery injury must be assessed and if there is a high index of suspicion, prompt advanced imaging is necessary.


Asunto(s)
Arteria Axilar , Fracturas del Hombro , Humanos , Arteria Axilar/lesiones , Arteria Axilar/cirugía , Arteria Axilar/diagnóstico por imagen , Fracturas del Hombro/cirugía , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/complicaciones , Anciano , Masculino , Femenino , Anciano de 80 o más Años , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/cirugía , Aneurisma Falso/etiología , Luxación del Hombro/cirugía , Luxación del Hombro/diagnóstico por imagen
2.
BMC Cardiovasc Disord ; 24(1): 462, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39198748

RESUMEN

BACKGROUND: Aortic arch disease is a major cause of acute dissections. Surgical replacement is the current curative treatment for aortic arch disease. While traditional aortic cannulation ensures lower body perfusion, axillary cannulation offers optimum cerebral perfusion. AIM: To evaluate the outcomes of aortic and axillary cannulation methods in hemiarch replacements, focusing on postoperative perfusion and survival. MATERIALS AND METHODS: A retrospective analysis was conducted on 91 patients who underwent hemiarch replacement surgery between February 2007 and October 2016. Patients were divided into two groups based on the cannulation method: aortic cannulation (54 patients) and axillary cannulation (37 patients). Data regarding preoperative, intraoperative, and postoperative parameters were analyzed, including demographics, surgical outcomes, and complications. RESULTS: Demographic analysis showed comparable characteristics between the two groups, with notable differences in aortic disease severity and classification. Patients in the axillary group had a larger ascending aorta diameter (57.7 ± 10.8 mm vs. 51.8 ± 5.7 mm, p = 0.002) and a higher prevalence of acute dissections (27.0% (n = 10) vs. 3.7% (n = 2), p = 0.001). Cerebral protection methods varied significantly between the two groups (p < 0.001). Antegrade cerebral perfusion was used in 37.8% (n = 14) of the axillary group compared to 3.7% (n = 2) of the central group. The central cannulation group had a higher proportion of patients with temperatures under 20 °C (98.1% (n = 53) vs. 21.6% (n = 8), p < 0.001), whereas the axillary group maintained higher temperatures (24 -28 °C) in 68.6% (n = 23) of cases. AV repair/replacement was more frequent in the aortic cannulation group (48.2% (n = 26) vs. 18.9% (n = 7), p = 0.013). No significant disparities were observed in operative mortality or intraoperative complications. Statistical analysis showed no significant differences between the two groups in the in-hospital outcomes, but renal complications were more prevalent in the axillary cannulation group with 21.6% (n = 8) experiencing acute kidney injury compared to 9.3% (n = 5) in the central group (p = 0.098). The overall survival rate was slightly higher in the aortic cannulation group at various follow-up periods, yet no statistically significant difference was found between the two groups. CONCLUSION: We found no significant differences in safety and efficacy between axillary cannulation and aortic cannulation in hemiarch replacement procedures.


Asunto(s)
Disección Aórtica , Arteria Axilar , Implantación de Prótesis Vascular , Cateterismo Periférico , Complicaciones Posoperatorias , Humanos , Estudios Retrospectivos , Femenino , Masculino , Persona de Mediana Edad , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Resultado del Tratamiento , Anciano , Factores de Riesgo , Disección Aórtica/cirugía , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Complicaciones Posoperatorias/etiología , Factores de Tiempo , Circulación Cerebrovascular , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Aorta Torácica/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología
3.
Future Cardiol ; 20(5-6): 305-316, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38963122

RESUMEN

Aim: To evaluate the effects of double (axillary and femoral) vs. single (axillary) cannulation on early outcomes of acute type A aortic dissection (ATAAD). Materials & methods: Meta-analysis using PubMed/MEDLINE, Scopus, and Cochrane databases through August 23, 2023. Focused on operative mortality, postoperative stroke, re-exploration for bleeding, spinal cord injury, and renal replacement therapy. Results: Among 5 propensity score-matched studies with 2127 patients, double cannulation showed comparable mortality and higher rates of postoperative stroke (pooled odds ratio: 1.69, 95% confidence interval: 1.19-2.39) and need for renal replacement therapy (pooled odds ratio: 1.35, 95% confidence interval: 1.13-1.60) compared with single cannulation. Conclusion: Double arterial cannulation in ATAAD surgery is associated with increased postoperative stroke and renal replacement therapy than single cannulation.


What is this summary about? We studied the optimal way to maintain blood flow during surgery for acute aortic dissection. We focused on comparing the use of one tube placement site in the axillary artery with two sites, both in the axillary and femoral arteries, in five previous studies.What were the results? Using two sites was associated with a higher risk of stroke and need for dialysis after surgery than using only one site.What do the results mean? Adding a tube in the femoral artery for blood flow may increase the risk of complications. It appears that placing the tube only in the axillary artery may be a safer choice for appropriately selected patients having this surgery.


Asunto(s)
Disección Aórtica , Arteria Axilar , Humanos , Disección Aórtica/cirugía , Enfermedad Aguda , Cateterismo/métodos , Cateterismo Periférico/métodos , Arteria Femoral , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control
4.
J Stroke Cerebrovasc Dis ; 33(9): 107845, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38950761

RESUMEN

OBJECTIVES: Giant cell arteritis (GCA) is the main systemic vasculitis in individuals aged ≥ 50 years. Color Doppler ultrasound (CDS) has an established role in GCA diagnosis and management. This study aims to assess the clinical characteristics associated with a positive CDS evaluation and the impact of additional axillary artery examination on diagnostic sensitivity. MATERIAL AND METHODS: We conducted a retrospective analysis of patients undergoing CDS of the superficial temporal arteries, with or without axillary artery assessment, at our hospital, between 2009 and 2023. Patients meeting the new 2022 diagnostic criteria for GCA were included and their characteristics were analyzed according to the presence of the halo sign on CDS. RESULTS: Of the 135 included patients (54 % female, mean age 75 ± 8 years), the halo sign was observed in 57 %, correlating with higher systemic symptom prevalence (61 % vs 42 %, p = 0.035), lower hemoglobin (p < 0.001), and higher erythrocyte sedimentation rate (p = 0.028). The halo sign inversely related to prior corticosteroid therapy (p = 0.033). Patients with axillary halo sign had fewer external carotid symptoms and a higher vertebral halo sign prevalence. Vertebral halo sign was associated with posterior circulation ischemic stroke (65 %, p < 0.001). Axillary artery studies improved diagnostic sensitivity by 9 %. CONCLUSION: In our study, the halo sign correlated with higher systemic symptoms and analytical abnormalities. Axillary artery examination enhanced CDS sensitivity, linked to severe outcomes like stroke. Prior corticosteroid therapy reduced CDS sensitivity. The correlation of clinical, laboratory, and ultrasound findings provides a more comprehensive understanding of GCA pathogenesis and evolution.


Asunto(s)
Arteria Axilar , Arteritis de Células Gigantes , Valor Predictivo de las Pruebas , Arterias Temporales , Ultrasonografía Doppler en Color , Humanos , Arteritis de Células Gigantes/diagnóstico por imagen , Arteritis de Células Gigantes/tratamiento farmacológico , Arteria Axilar/diagnóstico por imagen , Femenino , Anciano , Estudios Retrospectivos , Arterias Temporales/diagnóstico por imagen , Masculino , Anciano de 80 o más Años , Reproducibilidad de los Resultados , Persona de Mediana Edad
5.
Clin Transplant ; 38(7): e15404, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39023077

RESUMEN

BACKGROUND: The axillary artery (AX) access for intra-aortic balloon pump (IABP) as a bridge to heart transplant (HT) allows mobility while awaiting a suitable donor. As end-stage heart failure patients often have an implantable cardioverter defibrillator (ICD) on the left side, the left AX approach may be avoided due to the perception of difficult access and proximity of two devices. We aimed to evaluate the outcomes of patients bridged to HT with a left-sided AX IABP with or without ipsilateral ICDs. METHODS: We retrospectively reviewed HT candidates at our institution supported by left-sided axillary IABP from November 2019 to February 2024, dividing them into two groups based on the presence (Group ICD, n = 48) or absence (Group No-ICD, N = 19) of an ipsilateral left-sided ICD. The exposure time was defined as the time from skin incision to the beginning of anastomoses of a Dacron graft. RESULTS: Technical success was achieved in 100% of the cohort, with median exposure times for AX access similar between groups (ICD, 12 [7.8, 18.2] vs. No ICD, 11 [7, 19] min; p = 0.75). The rate of procedural adverse events, such as significant access site bleeding and ipsilateral limb ischemia, did not significantly differ between both groups. Device malfunction rates were comparable (ICD, 29.2% vs. No ICD, 15.8%; p = 0.35). Posttransplant, in-hospital mortality, severe primary graft dysfunction, and stroke rates were comparable in both groups. CONCLUSION: The presence of an ipsilateral left-sided ICD does not adversely impact the procedural efficacy, complication rates, or posttransplant outcomes of left-sided AX IABP insertion in HT candidates.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Trasplante de Corazón , Contrapulsador Intraaórtico , Humanos , Femenino , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/terapia , Estudios de Seguimiento , Pronóstico , Arteria Axilar
7.
BMJ Case Rep ; 17(6)2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38901855

RESUMEN

Takayasu arteritis is an inflammatory disease of unknown aetiology affecting large vessels. Medium vessel involvement is also well documented; however, neuropathy as a presenting manifestation is rare. In this case report, a young woman in her 20s presented with an 8-month history of intermittent claudication in the right upper limb progressing to rest pain with allodynia in C5-C8 distribution and painless right axillary mass. On examination, she had absent pulses in the right radial, brachial and subclavian artery with audible bruit in the right subclavian and abdominal aorta. CT angiogram showed features suggestive of Takayasu arteritis with a partially thrombosed aneurysm arising from the right axillary artery leading to compression of the right brachial plexus. This patient received treatment with methotrexate and oral corticosteroids. At 3 months follow-up, there was a reduction in the size of the aneurysm, resolution of compressive symptoms and normalisation of inflammatory markers.


Asunto(s)
Aneurisma , Arteria Axilar , Neuropatías del Plexo Braquial , Arteritis de Takayasu , Humanos , Arteritis de Takayasu/complicaciones , Arteritis de Takayasu/diagnóstico , Arteritis de Takayasu/tratamiento farmacológico , Femenino , Arteria Axilar/diagnóstico por imagen , Aneurisma/etiología , Aneurisma/diagnóstico por imagen , Aneurisma/complicaciones , Neuropatías del Plexo Braquial/etiología , Neuropatías del Plexo Braquial/diagnóstico , Adulto , Angiografía por Tomografía Computarizada , Metotrexato/uso terapéutico , Metotrexato/administración & dosificación
8.
J Clin Rheumatol ; 30(6): 243-246, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38787805

RESUMEN

OBJECTIVES: Vascular ultrasound is commonly used to diagnose giant cell arteritis (GCA). Most protocols include the temporal arteries and axillary arteries, but it is unclear which other arteries should be included. This study investigated whether inclusion of intima media thickness (IMT) of the common carotid artery (CCA) in the ultrasound evaluation of GCA improves the accuracy of the examination. METHODS: We formed a fast-track clinic to use ultrasound to rapidly evaluate patients with suspected GCA. In this cohort study, patients referred for new concern for GCA received a vascular ultrasound for GCA with the temporal arteries and branches, the axillary artery, and CCA. RESULTS: We compared 57 patients with GCA and 86 patients without GCA. Three patients with GCA had isolated positive CCA between 1 and 1.49 mm, and 21 patients without GCA had isolated positive CCA IMT. At the 1.5-mm CCA cutoff, 4 patients without GCA had positive isolated CCA, and 1 patient with GCA had a positive isolated CCA. The sensitivity of ultrasound when adding carotid arteries to temporal and axillary arteries was 84.21% and specificity 65.12% at an intima media thickness (IMT) cutoff of ≥1 mm and 80.70% and 87.21%, respectively, at a cutoff of ≥1.5 mm. CONCLUSION: Measurement of the CCA IMT rarely contributed to the diagnosis of GCA and increased the rate of false-positive results. Our data suggest that the CCA should be excluded in the initial vascular artery ultrasound protocol for diagnosing GCA. If included, an IMT cutoff of higher than 1.0 mm should be used.


Asunto(s)
Arteria Axilar , Arteria Carótida Común , Grosor Intima-Media Carotídeo , Arteritis de Células Gigantes , Arterias Temporales , Humanos , Arteritis de Células Gigantes/diagnóstico por imagen , Arteritis de Células Gigantes/diagnóstico , Femenino , Masculino , Anciano , Arteria Carótida Común/diagnóstico por imagen , Arterias Temporales/diagnóstico por imagen , Arteria Axilar/diagnóstico por imagen , Sensibilidad y Especificidad , Persona de Mediana Edad , Ultrasonografía/métodos , Anciano de 80 o más Años
9.
Catheter Cardiovasc Interv ; 104(1): 54-57, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38796712

RESUMEN

A 66-year-old man with multiple comorbidities including severe peripheral artery disease and heart failure with reduced ejection fraction presented with complex coronary artery disease with an elevated Society of Thoracic Surgeons Predicted Risk of Mortality for coronary artery bypass grafting and a Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery score of 18. With a multidisciplinary heart team approach, the patient successfully underwent percutaneous axillary venoarterial extracorporeal membrane oxygenation (VA-ECMO) supported high-risk percutaneous coronary intervention of a heavily calcified left main bifurcation lesion. Given the patient's peripheral artery disease, alternative arterial access for ECMO cannulation was performed percutaneously via the right axillary artery. Additionally, adequate coronary calcium modification was critical to successful stenting of a heavily calcified left main bifurcation. This case highlights a novel approach to obtaining alternative arterial access for ECMO cannulation and emphasizes the importance of calcium modification to achieve excellent stent results.


Asunto(s)
Arteria Axilar , Enfermedad de la Arteria Coronaria , Oxigenación por Membrana Extracorpórea , Calcificación Vascular , Humanos , Masculino , Anciano , Resultado del Tratamiento , Arteria Axilar/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Calcificación Vascular/terapia , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/fisiopatología , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/efectos adversos , Cateterismo Periférico , Enfermedad Arterial Periférica/terapia , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Stents , Angiografía Coronaria
10.
J Intensive Care Med ; 39(9): 916-921, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38794858

RESUMEN

BACKGROUND: Arterial catheter placement for hemodynamic monitoring is commonly performed in critically ill patients. The radial and femoral arteries are the two sites most frequently used; there is limited data on the use of the axillary artery for this purpose. The aim of this study was to investigate the rate of complications from ultrasound-guided axillary artery catheter placement in critically ill patients. METHODS: A retrospective study at a tertiary care center of patients admitted to an intensive care unit who had ultrasound-guided axillary artery catheter placement during admission. Primary outcome of interest was catheter related complications, including bleeding, vascular complications, compartment syndrome, stroke or air embolism, catheter malfunction, and need for surgical intervention. RESULTS: This study identified 88 patients who had an ultrasound-guided axillary artery catheter placed during their admission. Of these 88, nine patients required multiple catheters placed, for a total of 99 axillary artery catheter placement events. The median age was 64 [IQR 48, 71], 41 (47%) were female, and median body mass index (BMI) was 26 [IQR 22, 30]. The most common complication was minor bleeding (11%), followed by catheter malfunction (2%), and vascular complications (2%). Univariate analyses did not show any association between demographics and clinical variables, and complications related to axillary arterial catheter. CONCLUSION: The most common complication found with ultrasound-guided axillary artery catheter placement was minor bleeding, followed by catheter malfunction, and vascular complications. Ultrasound-guided axillary arterial catheters are an alternative in patients in whom radial or femoral arterial access is difficult or not possible to achieve.


Asunto(s)
Arteria Axilar , Cateterismo Periférico , Enfermedad Crítica , Unidades de Cuidados Intensivos , Ultrasonografía Intervencional , Humanos , Femenino , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Ultrasonografía Intervencional/métodos , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/métodos , Arteria Axilar/diagnóstico por imagen , Hemorragia/etiología
11.
BMC Vet Res ; 20(1): 194, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38734622

RESUMEN

In the left axilla of a formalin-embalmed adult female cross-breed dog, an unusual course of the axillary artery in relation to the brachial plexus was noted. A part of the axillary artery after the origin of the subscapular artery coursed through the loop formed by the contributions of the caudal pectoral and lateral thoracic nerves and then between the median and ulnar nerves. Thus, the common trunk for the latter two nerves was missing. Instead, in the proximal brachium, they communicated with each other in both directions. A communicating branch between the cranial and caudal pectoral nerves forming a nerve loop, ansa pectoralis lacked the axillary artery and was instead traversed by the subscapular artery. This is a variation in the relationship between the axillary artery and brachial plexus in the domestic dog and has not been reported in the literature yet. The axillary artery entrapped by the contributions of the caudal and lateral thoracic nerves may be considered as a risk factor for the neuroarterial compressions with non-specific signs and should be taken into account both in surgery and imaging.


Asunto(s)
Arteria Axilar , Plexo Braquial , Cadáver , Animales , Perros , Arteria Axilar/anatomía & histología , Plexo Braquial/anatomía & histología , Femenino , Terminología como Asunto
12.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38728442

RESUMEN

CASE: A 71-year-old woman presented with post-traumatic arthritis 11 months after open reduction and internal fixation for a left proximal humerus fracture (PHF) dislocation. After revision to reverse total shoulder arthroplasty (rTSA), the patient's left upper extremity was found to be avascular. An emergent thrombectomy was performed with restoration of arterial flow after removal of an acute-on-chronic axillary artery thrombus. CONCLUSION: Although rare, as rTSA becomes more common for management of PHF, incidence of associated vascular injuries is likely to rise. Screening methods and clinical vigilance in diagnosis are advised for patients with anterior PHF dislocations and arterial injury risk factors.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Arteria Axilar , Fracturas del Hombro , Trombosis , Humanos , Femenino , Anciano , Arteria Axilar/cirugía , Arteria Axilar/lesiones , Arteria Axilar/diagnóstico por imagen , Fracturas del Hombro/cirugía , Fracturas del Hombro/diagnóstico por imagen , Artroplastía de Reemplazo de Hombro/efectos adversos , Trombosis/etiología , Trombosis/diagnóstico por imagen , Trombosis/cirugía , Fijación Interna de Fracturas/efectos adversos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/diagnóstico por imagen , Reducción Abierta/efectos adversos , Reoperación
13.
J Appl Physiol (1985) ; 136(6): 1410-1417, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38660725

RESUMEN

It has been proposed that formation of abdominal aortic aneurysm (AAA) is part of a systemic arterial dilatative disease. However, arteries in the upper extremities are scarcely studied and it remains unclear whether both muscular and elastic arteries are affected by the proposed systemic arterial dilatation. The aim of this study was to investigate the diameter and stiffness of muscular and elastic arteries in arterial branches originating from the aortic arch. Twenty-six men with AAA (69 ± 4 yr) and 57 men without AAA (70 ± 5 yr) were included in the study. Ultrasound was used to examine the distal and proximal brachial artery, axillary artery, and common carotid artery (CCA), and measurement of diameter and diameter change was performed with wall-tracking software. Blood pressure measurements were used to calculate local arterial wall stiffness indices. The AAA cohort presented larger arterial diameters in the CCA and axillary artery after adjustment for body surface area (P = 0.002, respectively), whereas the brachial artery diameters were unchanged. Indices of increased stiffness in CCA (e.g., lower distensibility, P = 0.003) were seen in subjects with AAA after adjustments for body mass index and mean arterial blood pressure. This study supports the theory of a systemic arterial dilating diathesis in peripheral elastic, but not in muscular, arteries. Peripheral elastic arteries also exhibited increased stiffness, in analogy with findings in the aorta in AAA.NEW & NOTEWORTHY We present data partially supporting the notion of abdominal aortic aneurysm being a systemic vascular disease with focal manifestation in the abdominal aorta, from two well-defined groups recruited from a regional screening program. We show that elastic arteries distal from the aorta exhibit vascular alterations without aneurysmal formation in subjects with AAA compared with controls while muscular arteries seem unaffected.


Asunto(s)
Aneurisma de la Aorta Abdominal , Rigidez Vascular , Humanos , Masculino , Aneurisma de la Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Anciano , Rigidez Vascular/fisiología , Persona de Mediana Edad , Arteria Braquial/fisiopatología , Arteria Braquial/diagnóstico por imagen , Elasticidad , Presión Sanguínea/fisiología , Ultrasonografía/métodos , Arteria Axilar/fisiopatología , Arteria Axilar/diagnóstico por imagen , Arteria Carótida Común/diagnóstico por imagen , Arteria Carótida Común/fisiopatología
14.
BMJ Case Rep ; 17(4)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38684359

RESUMEN

We present a case of Takayasu's arteritis in a woman in her 30s, who exhibited visual symptoms and ophthalmic manifestations of the disease, specifically Takayasu's retinopathy stage 4, in both eyes. Despite severe narrowing of all branches of the aortic arch and compromised perfusion in both upper limbs, she had no history of intermittent claudication. Doppler study and CT angiography revealed diffuse circumferential wall thickening of bilateral common carotid, subclavian and axillary arteries. Treatment involved retinal laser photocoagulation and immune suppression. This case underscores that advanced Takayasu's retinopathy can be an initial presentation of Takayasu's arteritis even in a state of severely compromised peripheral limb circulation.


Asunto(s)
Arteritis de Takayasu , Humanos , Arteritis de Takayasu/complicaciones , Arteritis de Takayasu/diagnóstico , Femenino , Adulto , Enfermedades de la Retina/etiología , Enfermedades de la Retina/diagnóstico , Arteria Axilar/diagnóstico por imagen , Arteria Subclavia/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Coagulación con Láser
17.
Ann Thorac Surg ; 117(6): 1128-1134, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38458510

RESUMEN

BACKGROUND: Cannulation strategy in acute type A dissection (ATAD) varies widely without known gold standards. This study compared ATAD outcomes of axillary vs femoral artery cannulation in a large cohort from the International Registry of Acute Aortic Dissection (IRAD). METHODS: The study retrospectively reviewed 2145 patients from the IRAD Interventional Cohort (1996-2021) who underwent ATAD repair with axillary or femoral cannulation (axillary group: n = 1106 [52%]; femoral group: n = 1039 [48%]). End points included the following: early mortality; neurologic, respiratory, and renal complications; malperfusion; and tamponade. All outcomes are presented as axillary with respect to femoral. RESULTS: The proportion of patients younger than 70 years in both groups was similar (n = 1577 [74%]), as were bicuspid aortic valve, Marfan syndrome, and previous dissection. Patients with femoral cannulation had slightly more aortic insufficiency (408 [55%] vs 429 [60%]; P = .058) and coronary involvement (48 [8%] vs 70 [13%]; P = .022]. Patients with axillary cannulation underwent more total aortic arch (156 [15%] vs 106 [11%]; P = .02) and valve-sparing root replacements (220 [22%] vs 112 [12%]; P < .001). More patients with femoral cannulation underwent commissural resuspension (269 [30.9%] vs 324 [35.3%]; P = .05). Valve replacement rates were not different. The mean duration of cardiopulmonary bypass was longer in the femoral group (190 [149-237] minutes vs 196 [159-247] minutes; P = .037). In-hospital mortality was similar between the axillary (n = 165 [15%]) and femoral (n = 149 [14%]) groups (P = .7). Furthermore, there were no differences in stroke, visceral ischemia, tamponade, respiratory insufficiency, coma, or spinal cord ischemia. CONCLUSIONS: Axillary cannulation is associated with a more stable ATAD presentation, but it is a more extensive intervention compared with femoral cannulation. Both procedures have equivalent early mortality, stroke, tamponade, and malperfusion outcomes after statistical adjustment.


Asunto(s)
Disección Aórtica , Arteria Axilar , Arteria Femoral , Humanos , Disección Aórtica/cirugía , Disección Aórtica/mortalidad , Femenino , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/mortalidad , Cateterismo Periférico/métodos , Enfermedad Aguda , Sistema de Registros , Resultado del Tratamiento
18.
Lancet Rheumatol ; 6(5): e291-e299, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38554720

RESUMEN

BACKGROUND: Giant cell arteritis is a critically ischaemic disease with protean manifestations that require urgent diagnosis and treatment. European Alliance of Associations for Rheumatology (EULAR) recommendations advocate ultrasonography as the first investigation for suspected giant cell arteritis. We developed a prediction tool that sequentially combines clinical assessment, as determined by the Southend Giant Cell Arteritis Probability Score (SGCAPS), with results of quantitative ultrasonography. METHODS: This prospective, multicentre, inception cohort study included consecutive patients with suspected new onset giant cell arteritis referred to fast-track clinics (seven centres in Italy, the Netherlands, Spain, and UK). Final clinical diagnosis was established at 6 months. SGCAPS and quantitative ultrasonography of temporal and axillary arteries with three scores (ie, halo count, halo score, and OMERACT GCA Score [OGUS]) were performed at diagnosis. We developed prediction models for diagnosis of giant cell arteritis by multivariable logistic regression analysis with SGCAPS and each of the three ultrasonographic scores as predicting variables. We obtained intraclass correlation coefficient for inter-rater and intra-rater reliability in a separate patient-based reliability exercise with five patients and five observers. FINDINGS: Between Oct 1, 2019, and June 30, 2022, we recruited and followed up 229 patients (150 [66%] women and 79 [34%] men; mean age 71 years [SD 10]), of whom 84 were diagnosed with giant cell arteritis and 145 with giant cell arteritis mimics (controls) at 6 months. SGCAPS and all three ultrasonographic scores discriminated well between patients with and without giant cell arteritis. A reliability exercise showed that the inter-rater and intra-rater reliability was high for all three ultrasonographic scores. The prediction model combining SGCAPS with the halo count, which was termed HAS-GCA score, was the most accurate model, with an optimism-adjusted C statistic of 0·969 (95% CI 0·952 to 0·990). The HAS-GCA score could classify 169 (74%) of 229 patients into either the low or high probability groups, with misclassification observed in two (2%) of 105 patients in the low probability group and two (3%) of 64 of patients in the high probability group. A nomogram for easy application of the score in daily practice was created. INTERPRETATION: A prediction tool for giant cell arteritis (the HAS-GCA score), combining SGCAPS and the halo count, reliably confirms and excludes giant cell arteritis from giant cell arteritis mimics in fast-track clinics. These findings require confirmation in an independent, multicentre study. FUNDING: Royal College of Physicians of Ireland, FOREUM.


Asunto(s)
Arteritis de Células Gigantes , Ultrasonografía , Arteritis de Células Gigantes/diagnóstico por imagen , Humanos , Femenino , Anciano , Masculino , Estudios Prospectivos , Ultrasonografía/métodos , Reproducibilidad de los Resultados , Arterias Temporales/diagnóstico por imagen , Arterias Temporales/patología , Anciano de 80 o más Años , Arteria Axilar/diagnóstico por imagen , Persona de Mediana Edad , Valor Predictivo de las Pruebas
19.
Curr Probl Cardiol ; 49(5): 102488, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38417474

RESUMEN

BACKGROUND: Transcatheter Aortic Valve Replacement (TAVR) is the treatment of choice in patients with severe aortic stenosis. Transcarotid (TCa) or Trans-axillary/subclavian (TAx/Sc) are safer and less invasive non-femoral approaches, where transfemoral access is difficult or impossible to obtain. METHODS: This meta-analysis was performed based on PRISMA guidelines after registering in PROSPERO (CRD42023482842). This meta-analysis was performed to compare the safety of the transcarotid and trans-axillary/subclavian approach for TAVR including studies from inception to October 2023. RESULTS: Seven studies with a total of 6227 patients were included in the analysis (TCa: 2566; TAx/Sc: 3661). Transcarotid TAVR approach had a favorable trend for composite of stroke and all-cause mortality (OR 0.79, CI 0.60-1.04), all-cause mortality, stroke, major vascular complication, and new requirement of permanent pacemaker though those were statistically insignificant. On sub-analysis of the results of the studies based on the territory (USA vs French), composite outcome of all cause mortality, stroke and major bleeding (OR 0.54, CI 0.54-0.81), composite of stroke and all cause mortality (OR 0.64, CI 0.50-0.81), and stroke/TIA (OR 0.53, CI 0.39-0.73) showed lower odds of occurrence among patient managed with TCa approach in the American cohort. CONCLUSION: Overall, transcarotid approach had favorable though statistically insignificant odds for composite (stroke and all-cause mortality) and individual outcomes (stroke, all-cause mortality, etc.). There are significant variations in observed outcomes based on study's geographic location. Large prospective randomized clinical trials comparing the two approaches with representative samples are necessary to guide the clinicians in choosing among these approaches.


Asunto(s)
Estenosis de la Válvula Aórtica , Arteria Axilar , Arteria Subclavia , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Arteria Subclavia/cirugía , Arterias Carótidas/cirugía , Resultado del Tratamiento , Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología
20.
Asian Cardiovasc Thorac Ann ; 32(4): 234-243, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38343086

RESUMEN

BACKGROUND: Research comparing the effectiveness of central aortic cannulation to axillary artery cannulation in repairing acute type A aortic dissection is limited and controversial. This meta-analysis aimed to compare early outcomes of central aortic cannulation versus axillary artery cannulation for surgery for acute aortic dissection type A. METHODS: A comprehensive systematic search was conducted across PubMed/MEDLINE, Scopus, and the Cochrane Central Register of Controlled Trials up to September 1, 2023. The primary endpoints were operative mortality and incidence of postoperative stroke. Secondary endpoints encompassed cardiopulmonary bypass time, myocardial ischemic time, hypothermic circulatory arrest time, postoperative temporary neurological dysfunction, combination of stroke and temporary neurological dysfunction, as well as the need for reexploration for bleeding, renal replacement therapy, and tracheotomy. A random-effect model was utilized to calculate the pooled effect size. RESULTS: Eleven studies met our eligibility criteria, enrolling a total of 7204 patients (2760 underwent aortic cannulation and 4444 underwent axillary cannulation). The operative mortality and incidence of postoperative stroke did not show statistical differences between the two groups, with a pooled odds ratio of 1.07 (95% confidence interval: 0.73-1.55) and 1.17 (0.95-1.42), respectively. Similarly, none of the secondary endpoints exhibited significant statistical differences between the two groups. CONCLUSIONS: Aortic cannulation can be a viable alternative to axillary artery cannulation for repair of acute aortic dissection type A, as both approaches present similar early clinical outcomes.


Asunto(s)
Aneurisma de la Aorta , Disección Aórtica , Arteria Axilar , Cateterismo Periférico , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Aguda , Aorta/cirugía , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/mortalidad , Aneurisma de la Aorta/diagnóstico por imagen , Disección Aórtica/cirugía , Disección Aórtica/mortalidad , Disección Aórtica/diagnóstico por imagen , Arteria Axilar/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...