Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 618
Filtrar
1.
J Cataract Refract Surg ; 50(4): 430-435, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38523280

RESUMEN

A 28-year-old nurse had an aberration-free femto-laser in situ keratomileusis (LASIK) performed for her myopia of -6.25 -0.50 × 096 and -6.75 -0.50 × 175 in the right and left eye, respectively. Corrected distance visual acuity (CDVA) preoperatively was 20/16. Preoperatively, there were no abnormalities on Scheimpflug imaging, and a pachymetry of 585 µm was measured in both eyes. Flap thickness was 115 µm. The patient was quite nervous during the surgery. Since the surgery, her uncorrected distance visual acuity (UDVA) and CDVA are suboptimal at 20/30 and 20/20 in the right eye, and 20/20 and 20/16 in the left eye. 3 months postoperatively, there is a stable manifest refraction of +0.25 -1.25 × 030 and +0.25 -0.00 × 0. The keratometric astigmatism in the Scheimpflug imaging is 1.2 diopter (D) × 114 and 0.4 D × 78 in the right and left eyes, respectively (FIgures 1 and 2). Thinnest pachymetry is 505 µm and 464 µm in the right and left eye, respectively. Her wavefront analysis shows refraction in a 6 mm zone of -0.99 -1.22 × 32 and -0.91 -0.36 × 136. The cycloplegic refraction is 1.25 -1.00 × 023 and +1.00 -0.25 × 006 (Figures 3 and 4). What is the cause of the suboptimal visual outcome in this case? What would be your treatment strategy to improve visual outcome?


Asunto(s)
Astigmatismo , Aberración de Frente de Onda Corneal , Queratomileusis por Láser In Situ , Miopía , Humanos , Femenino , Adulto , Queratomileusis por Láser In Situ/métodos , Aberración de Frente de Onda Corneal/cirugía , Resultado del Tratamiento , Agudeza Visual , Refracción Ocular , Miopía/cirugía , Miopía/complicaciones , Astigmatismo/cirugía , Astigmatismo/complicaciones , Láseres de Excímeros/uso terapéutico
3.
Int Ophthalmol ; 44(1): 111, 2024 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-38403780

RESUMEN

PURPOSE: To compare refractive outcomes after transepithelial photorefractive keratectomy (tPRK) and combined phototherapeutic keratectomy (PTK-PRK) procedure using two different excimer laser platforms for correction of myopia and myopic astigmatism. METHODS: In this retrospective multicenter study, we compared the results of two different PRK methods. The first group received a tPRK treatment with the Amaris750 excimer laser (Schwind eye-tech solutions). The second group received a combined PTK-PRK treatment with the MEL90 excimer laser (Carl Zeiss). Only healthy eyes with no previous surgery and a spherical equivalent (SE) of -1 to -8 diopters (D) were included. Preoperative spherical equivalent (SE), age, and sex were matched among the two groups. All treatments were performed by the same surgeon in different clinics. This study was approved by the local Ethics Committee (No. 2022-1980). RESULTS: We included 154 eyes of 86 patients in our study. There was no difference in predictability of SE between the two groups. Efficacy and safety indices were equally high in both groups. Similarly, no significant differences were seen in change of higher order aberrations (HOA) between the two groups (p > 0.05). No complications occurred. CONCLUSION: Both investigated methods provide safe and effective refractive results. The combination of PTK with PRK may be a suitable option to the already used one-step tPRK for the correction of myopia.


Asunto(s)
Astigmatismo , Miopía , Queratectomía Fotorrefractiva , Humanos , Queratectomía Fotorrefractiva/métodos , Astigmatismo/cirugía , Astigmatismo/complicaciones , Agudeza Visual , Refracción Ocular , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Miopía/complicaciones , Córnea/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
4.
Curr Eye Res ; 49(1): 46-52, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37789513

RESUMEN

PURPOSE: To compare 5-year outcomes of toric intraocular lens (tIOL) or peripheral corneal relaxing incision (PCRI) for correction of keratometric astigmatism (KA) between 0.75 and 2.5 diopters (D). METHODS: Setting: University Hospital. Design: Randomized clinical trial. Eighty eyes (80 participants) received either tIOL or PCRI. Patients were assessed preoperatively, 1-month, 1, and 5 years. Primary outcomes were uncorrected (UDVA) and best-corrected distance logMAR visual acuity (CDVA). Secondary outcomes were a manifest refractive sphere, refractive astigmatism (Ra), spherical equivalent (SEQ), KA & mean keratometry (KM), and Quality-of-Life Impact of Refractive Correction (QIRC) scores. RESULTS: There was no difference between the two groups in UDVA, CDVA, refractive sphere, KM, RA, and SEQ. KA reduced after 1 month in the PCRI group and remained stable until 5 years. From 1 to 5 years, the number of eyes with distance emmetropia (within ±0.13D) changed from 59% (20/34 eyes) to 32% (6/19 eyes) for tIOLs and from 43% (15/36 eyes) to 20% (4/21 eyes) for PCRIs with 32% (6/19 eyes) and 20% (4/21 eyes) showing >0.5D change in SEQ at 5-years respectively. Compared to 1-year, Ra significantly increased at 5 years in both groups with no difference between the groups. Mean overall QIRC scores were not different between the groups (tIOL: 49.88 ± 7.47; PCRI: 52.09 ± 7.02; p = .18). CONCLUSIONS: Although there was no difference between the overall visual and vision-related quality of life outcomes between tIOLs and PCRIs, an increase in refractive astigmatism and reduction in distance emmetropia with time was noted in both groups.


Asunto(s)
Astigmatismo , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares , Astigmatismo/cirugía , Astigmatismo/complicaciones , Calidad de Vida , Refracción Ocular
5.
J Cataract Refract Surg ; 50(3): 230-235, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37847149

RESUMEN

PURPOSE: To compare the accuracy of toric intraocular lens (IOL) alignment between femtosecond laser-assisted capsular marking and digital marking. SETTING: Ruhr University Eye Clinic, Bochum, Germany. DESIGN: Prospective clinical trial. METHODS: In this study, 28 eyes of 23 patients, who underwent femtosecond laser-assisted cataract surgery with implantation of a toric IOL, were included. Intraoperatively, both femtosecond laser-assisted capsular marking and digital marking were applied simultaneously and compared in every case. The toric IOL was aligned to the capsular markings. Postoperatively, the axis of the capsular markings and toric IOL alignment was examined. Visual acuity and refractive outcomes were evaluated. RESULTS: Both alignment methods were performed without intraoperative complications in all cases. 25 eyes were included in the final analysis. Misalignment was significantly lower with femtosecond laser-assisted capsular marking than with digital marking (1.71 ± 1.25 degrees vs 2.64 ± 1.70 degrees, P = .016). Deviation from the target axis of the toric IOL was 1.62 ± 1.24 degrees 4 to 6 weeks postoperatively. Postoperative uncorrected distance visual acuity was 0.14 ± 0.13 logMAR, and residual astigmatism was 0.3 ± 0.23 diopter (D) with an astigmatism ≤0.5 D in 93% of eyes. CONCLUSIONS: Both methods showed excellent results for the alignment of toric IOLs. However, femtosecond laser-assisted capsular marking was significantly more precise than digital marking and showed good refractive results. In addition, capsular marking offers the possibility to avoid parallax error and evaluating postoperative IOL rotation.


Asunto(s)
Astigmatismo , Extracción de Catarata , Catarata , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares/métodos , Estudios Prospectivos , Astigmatismo/cirugía , Astigmatismo/complicaciones , Extracción de Catarata/métodos , Refracción Ocular , Catarata/complicaciones
6.
Zhonghua Yan Ke Za Zhi ; 59(12): 1030-1037, 2023 Dec 11.
Artículo en Chino | MEDLINE | ID: mdl-38061904

RESUMEN

Objective: To explore and analyze the distribution characteristics of chord µ related parameters, as well as the pupil center's relative position to the coaxial corneal light reflex on the corneal surface, and the influencing factors in young myopia. Methods: This was a cross-sectional study. A total of 761 myopic patients (761 eyes) were collected from March 2021 to December 2021 in the Refractive Surgery Center of Tianjin Eye Hospital, including 388 males and 373 females, with an average age of (24±6) years. The relationship between age, sex, diopter, anterior and posterior corneal surface parameters, and chord µ related parameters was analyzed, including the x and y absolute values of the pupil center, chord µ length, and angle. The normality of the data was tested using the Kolmogorov-Smirnov test, and the influencing factors of chord µ were analyzed through Pearson and Spearman correlation analysis. Results: The equivalent spherical degree and chord µ length were (-5.47±1.66) D and (0.178±0.095) mm, respectively. The chord µ length followed an approximately normal distribution. The chord µ length of 266 eyes (35%) was distributed in the range of 0.120 to 0.200 mm, while the chord µ length of 479 eyes (63%) was<0.200 mm, and the chord µ length of 620 eyes (81%) was<0.260 mm. The chord µ angle distribution accounted for the largest proportion in the superior nasal quadrant (45.6%), followed by the superior temporal quadrant (34.3%), the inferior temporal quadrant (10.1%), and the inferior nasal quadrant (10.0%). High myopia (r=0.11, P=0.002) and high astigmatism (r=0.08, P=0.023) were associated with an increase in chord µ length. The higher the degree of myopia, the smaller the chord µ angle (r=-0.09, P=0.019). The larger the ISV (r=0.09, P=0.017), IVA (r=0.08, P=0.025), and IHD (r=0.08, P=0.039) on the anterior surface of the cornea, the longer the chord µ length. The higher the astigmatism of the posterior corneal surface, the greater the absolute value of the Y coordinate of the pupil center (r=0.07, P=0.044), and the longer the chord µ length (r=0.08, P=0.035), and the smaller the chord µ angle (r=-0.08, P=0.032). Conclusions: The chord µ length of young myopic individuals in China followed an approximately normal distribution, with the majority located in the superior nasal and superior temporal quadrants. High myopia, high astigmatism, and irregular corneal shape are the main factors related to an increase in chord µ length.


Asunto(s)
Astigmatismo , Miopía , Procedimientos Quirúrgicos Refractivos , Masculino , Femenino , Humanos , Adolescente , Adulto Joven , Adulto , Astigmatismo/complicaciones , Estudios Transversales , Córnea , Miopía/cirugía , Topografía de la Córnea , Refracción Ocular
7.
BMC Ophthalmol ; 23(1): 449, 2023 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-37950161

RESUMEN

BACKGROUND: To investigate the prevalence and risk factors of refractive astigmatism (RA) and corneal astigmatism (CA) in preschool children and school-aged children in Shanghai, China. METHODS: In this school-based, cross-sectional study, 4-15 years old children across three learning stages of kindergarten, primary school, and junior high school underwent noncycloplegic autorefraction and completed comprehensive questionnaires involving time spent on daily homework and outdoor activities. Data from the right eyes were analysed. RESULTS: Overall, 7084 children (mean ± standard deviation (SD) of age: 8.08 ± 3.11 years) were included, and the prevalence rates of RA/CA ( ≤ - 1.0 D) in children were 15.8%/64% in kindergartens, 16.5%/65% in primary schools, and 32.8%/76.9% in junior high schools. The magnitude and prevalence of RA and CA all increased with age or with learning stage (all P < 0.001). The presence of RA was associated with more myopic spherical power (odds ratio (OR) 0.956, P = 0.021), junior high school (OR 1.973, P < 0.001), longer homework time on weekdays (OR 1.074, P = 0.029), and shorter outdoor activity time on weekends (odds ratio 0.929, P = 0.013). CONCLUSION: In the wide age range of 4 to 15 years, the magnitude and prevalence of RA and CA increased with the learning stage, and these increases mainly began at the primary school stage. Factors, including longer homework time and shorter outdoor time were correlated with the presence of RA.


Asunto(s)
Astigmatismo , Enfermedades de la Córnea , Preescolar , Humanos , Niño , Adolescente , Astigmatismo/epidemiología , Astigmatismo/complicaciones , Prevalencia , Estudios Transversales , Pueblos del Este de Asia , China/epidemiología , Refracción Ocular , Enfermedades de la Córnea/complicaciones , Factores de Riesgo
8.
BMC Ophthalmol ; 23(1): 485, 2023 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-38008718

RESUMEN

BACKGROUND: This study aimed to identify an initial screening tool for congenital ectopia lentis (CEL) by comparing ocular biological parameters in children with myopia. METHODS: A retrospective case-control study was conducted at one tertiary referral centre, from October 2020 to June 2022. Axial length (AL), corneal curvature (CC), refractive astigmatism (RA), corneal astigmatism (CA), internal astigmatism (IA), the difference between the axis of RA and CA [AXIS(RA-CA)], white-to-white corneal diameter (WTW), and axial length-corneal radius ratio (AL/CR) were compared in 28 eyes of CEL patients, and 60 eyes of myopic patients matched for age and refraction. The spherical equivalent of each eye was < -3.00 D. Area under the curve (AUC) of the receiver operating characteristic curves were calculated. RESULTS: The differences in RA, AL, mean keratometry (Kmed), maximum keratometry (Kmax), minimum keratometry (Kmin), CA, IA, AXIS(RA-CA), WTW, and AL/CR between the CEL and myopic groups were statistically significant (p < 0.05; p < 0.001; p < 0.001; p < 0.001; p < 0.001; p < 0.05; p < 0.001; p < 0.001; p < 0.001; p < 0.001, respectively). In logistic regression analysis RA, IA, AXIS(RA-CA), and AL/CR were significantly associated with CEL (p < 0.05). AUCs for RA, IA, AXIS(RA-CA), and AL/CR were 0.694, 0.853, 0.814, and 0.960, respectively. AUCs for AL/CR in SE< -6.00 D subgroup was 0.970, and 0.990 in -6.00 D ≤ SE < -3.00 D group. An AL/CR < 3.024 was the optimal cut-off point differentiating the CEL and control groups (sensitivity, 92.9%; specificity, 88.30%). CONCLUSIONS: A smaller AL/CR could identify CEL in children with myopia. An AL/CR cut-off value of 3.024 may be the most sensitive and specific parameter for the differential diagnosis of CEL in patients with mild to high myopia.


Asunto(s)
Astigmatismo , Desplazamiento del Cristalino , Miopía , Humanos , Preescolar , Desplazamiento del Cristalino/diagnóstico , Desplazamiento del Cristalino/complicaciones , Astigmatismo/diagnóstico , Astigmatismo/complicaciones , Estudios Retrospectivos , Estudios de Casos y Controles , Refracción Ocular , Córnea , Miopía/diagnóstico , Miopía/complicaciones
9.
Rom J Ophthalmol ; 67(3): 267-274, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37876510

RESUMEN

Purpose: To compare the outcomes of transepithelial photorefractive keratectomy (transPRK) with femtosecond laser assisted in situ keratomileusis (FS-LASIK) for the correction of astigmatism on amblyopic eyes. Methods: The design was a retrospective interventional study on 37 eyes with hyperopic or mixed astigmatism and refractive amblyopia, which underwent transPRK or FS-LASIK. The patients were distributed into 2 groups according to the technique used. Data was collected from patient files and comparison between groups was performed. The main outcomes measured were corrected distance visual acuity (CDVA), sphere, cylinder, spherical equivalent (SEQ), efficiency and safety indexes. Results: In the transPRK group, SEQ improved significantly after 1 month, from 2.08 ± 2.02D (p<0.01) to 0.125 ± 0.86D and at the 12 month visit to -0.04 ± 0.62D (p>0.05), sphere improved from 4.03 ± 1.44D preoperatively to 0.67 ± 0.9D at 1 month (p<0.05) and further to 0.44 ± 0.71 at 12 months (p<0.05). CDVA improved from 0.194 ± 0.11 logMAR to 0.115 ± 0.1 logMAR at the 1-year visit. Safety index after 1 month was 1.09 ± 0.2 and 1.12 ± 0.35 at the 1-year visit. Efficiency index was 0.95 ± 0.22 at 1 month and 1.03 ± 0.34 after 1 year. In FS-LASIK group, SEQ improved after 1 month, from 2.28 ± 3.04 to -0.79 ± 0.73D (p<0.01), and further to -0.49 ± 0.79 (p>0.05) at the 12 month visit, sphere improved from 4.11 ± 2.35D preoperatively to -0.42 ± 0.66D at 1 month (p<0.05) and further to -0.08 ± 0.75D at 12 months (p<0.05). CDVA also improved from 0.191 ± 0.1 logMAR to 0.140 ± 0.1 logMAR at 1 year. Safety index after 1 month was 1.1 ± 0.2 and 1.16 ± 0.21 at the 1-year visit. Efficiency index was 0.98 ± 0.27 at 1 month and 1.06 ± 0.23 after 1 year. Conclusion: Both procedures were safe and efficient in improving visual acuity for patients with mixed and hyperopic astigmatism and refractive amblyopia. Abbreviations: transPRK = transepithelial photorefractive keratectomy, FS-LASIK = femtosecond laser in situ keratomileusis, logMAR = logarithm of the Minimum Angle of Resolution, BCVA = best corrected distance visual acuity, CDVA = corrected distance visual acuity.


Asunto(s)
Ambliopía , Astigmatismo , Queratomileusis por Láser In Situ , Miopía , Queratectomía Fotorrefractiva , Humanos , Queratomileusis por Láser In Situ/métodos , Astigmatismo/complicaciones , Astigmatismo/cirugía , Ambliopía/cirugía , Estudios Retrospectivos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Queratectomía Fotorrefractiva/métodos , Resultado del Tratamiento
10.
Braz J Psychiatry ; 45(5): 397-404, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37718319

RESUMEN

OBJECTIVES: The present study analyzed the reciprocal relationships between four common pediatric ophthalmic diseases (i.e., hyperopia, myopia, astigmatism, and strabismus) and attention-deficit/hyperactivity disorder (ADHD) in children. METHODS: This study enrolled 86,028 children with ADHD and 1,798,673 children without ADHD in the Taiwan Maternal and Child Health Database who were born at any time from 2004 to 2017. Cox proportional hazards regression models were used to estimate the bidirectional relationships of the four ophthalmic diseases with ADHD in children after adjusting for age, sex, and gestational age at birth. Survival curves for time-to-event variables were estimated using the Kaplan-Meier method, and the log-rank test was used to compare the curves. RESULTS: The results indicated that ADHD significantly predicted the occurrence of hyperopia, myopia, astigmatism, and strabismus. Furthermore, hyperopia, myopia, astigmatism, and strabismus significantly predicted the occurrence of ADHD. The time between enrollment and ADHD diagnosis was shorter for patients with ophthalmic diseases than for the control group, and the time between enrollment and ophthalmic disease diagnosis was also shorter for ADHD patients than for the control group. Sex differences were found in the associations between ADHD and ophthalmic diseases. CONCLUSION: Clinicians should monitor children with ADHD for hyperopia, myopia, astigmatism, and strabismus to ensure appropriate treatment, and vice versa.


Asunto(s)
Astigmatismo , Trastorno por Déficit de Atención con Hiperactividad , Hiperopía , Miopía , Estrabismo , Recién Nacido , Humanos , Niño , Femenino , Masculino , Astigmatismo/complicaciones , Astigmatismo/diagnóstico , Astigmatismo/epidemiología , Hiperopía/epidemiología , Hiperopía/complicaciones , Hiperopía/diagnóstico , Trastorno por Déficit de Atención con Hiperactividad/epidemiología , Estudios de Cohortes , Miopía/complicaciones , Miopía/diagnóstico , Miopía/epidemiología , Estrabismo/epidemiología , Estrabismo/complicaciones , Estrabismo/diagnóstico
11.
BMC Ophthalmol ; 23(1): 332, 2023 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-37474888

RESUMEN

BACKGROUND: To evaluate the influence of decentration of plate-haptic toric intraocular lens (IOLs) on visual quality. METHODS: This study enrolled 78 eyes of 78 patients. Patients in group A were implanted with toric IOLs, and patients in group B were implanted with monofocal IOLs. All patients were divided into group A1 and B1 (decentration below 0.3 mm) and group A2 and B2 (decentration above 0.3 mm). The uncorrected distance visual acuity (UDVA), best corrected visual acuity (BCVA), modulation transfer function cutoff (MTF cutoff), objective scatter index (OSI), strehl ratio (SR), optical interference and patients' satisfaction were measured in different pupils at three months postoperatively. The associations between decentration and visual quality were analyzed by Spearman correlation. RESULTS: There were no significant differences in UDVA, BCVA, MTF cutoff, OSI, SR, optical interference and patients' satisfaction among subgroups. The differences in decentration between groups A and B were not statistically significant. In group A2, the total higher order aberrations (tHOAs) at pupil sizes of 3 mm (P = 0.046), 5 mm (P = 0.014), spherical aberrations at pupil sizes of 3 mm (P = 0.011), 4 mm (P = 0.014), 5 mm (P = 0.000), secondary astigmatism at pupil sizes of 3 mm (P = 0.002), 4 mm (P = 0.005) were higher than in group B2. Compared to group A1, group A2 had higher spherical aberrations at pupil sizes of 4 mm (P = 0.042), 5 mm (P = 0.001), 6 mm (P = 0.038), secondary astigmatism at pupil sizes of 3 mm (P = 0.013), 4 mm (P = 0.005), 6 mm (P = 0.013). Group B2 has higher coma and secondary astigmatism than group B1 at 6-mm pupil (P = 0.014, P = 0.045). Significant positive correlations were found between spherical aberrations and the decentration of group A1 and A2 at 6-mm pupils. CONCLUSION: The decentration above 0.3 mm negatively affected visual quality due to increased tHOAs, spherical aberrations, coma and secondary astigmatism aberrations, the influence become larger with increasing pupil diameter. And toric IOLs are more affected by decentration than monofocal IOLs.


Asunto(s)
Astigmatismo , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares , Astigmatismo/cirugía , Astigmatismo/complicaciones , Coma/complicaciones , Coma/cirugía , Tecnología Háptica
12.
J Cataract Refract Surg ; 49(9): 964-969, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37395497

RESUMEN

PURPOSE: To evaluate the long-term (8-10 years) outcomes of toric implantable collamer lens (TICL) surgery. SETTING: Nagoya Eye Clinic, Nagoya, Aichi, Japan. DESIGN: Retrospective observational study. METHODS: Patients who underwent TICL surgery from 2005 to 2009 to correct myopia and myopic astigmatism were enrolled. The safety, efficacy, predictability, astigmatism correction efficacy, and complications were evaluated using preoperative, 1-year postoperative, and final examination data. RESULTS: 133 eyes of 77 patients were included. At the final visit, the mean uncorrected and corrected visual acuities were -0.01 ± 0.2 and -0.17 ± 0.05, respectively. The mean safety and efficacy indices were 0.91 ± 0.26 and 0.68 ± 0.21, respectively. The manifest astigmatism was -0.45 ± 0.43 diopters (D). The mean corneal astigmatism change from 1 year postoperatively to the final visit was 0.40 ± 0.26 D. Of the 38 eyes with a change in corneal astigmatism ≥0.5 D, 30 eyes (78.9%) changed to against-the-rule (ATR) astigmatism, 1 (2.6%) changed to oblique astigmatism, and 7 (18.4%) changed to with-the-rule (WTR) astigmatism. The mean manifest astigmatism change from 1 year postoperatively to the final visit was 0.43 ± 0.52 D. Of the 60 eyes with a change in manifest astigmatism ≥0.5 D, 25 (41.7%) changed to ATR astigmatism, 18 (30.0%) changed to oblique astigmatism, and 17 (28.3%) changed to WTR astigmatism. During follow-up, 8 (6.0%) of 133 eyes developed anterior subcapsular cataracts, among which 4 (3.0%) underwent TICL removal and phacoemulsification and aspiration. No vision-threatening complications occurred. CONCLUSIONS: TICL surgery showed good long-term astigmatism-correcting effects, although the long-term uncorrected visual acuity decreased. The procedure was effective in correcting myopia and astigmatism.


Asunto(s)
Astigmatismo , Enfermedades de la Córnea , Miopía , Lentes Intraoculares Fáquicas , Humanos , Refracción Ocular , Astigmatismo/cirugía , Astigmatismo/complicaciones , Implantación de Lentes Intraoculares , Miopía/cirugía , Miopía/complicaciones , Enfermedades de la Córnea/cirugía , Resultado del Tratamiento
13.
Jpn J Ophthalmol ; 67(5): 560-564, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37289297

RESUMEN

PURPOSE: Plate-haptic rotationally asymmetric multifocal toric intraocular lenses (IOL) (Lentis Comfort Toric) occasionally rotate extensively after surgery. We conducted the current study to investigate the incidence of extensive misalignment of this IOL and its association with clinical parameters. STUDY DESIGN: Retrospective case series. SUBJECTS AND METHODS: Data were collected from patients who had undergone phacoemulsification and implantation of a plate-haptic multifocal toric IOL. RESULTS: Among 332 eyes, extensive misalignment of toric IOLs ≥ 45º occurred in 3.3% (11 eyes). The amount of misalignment in eyes with extensive misalignment was 81.6 ± 22.9º, while in those without extensive misalignment, it was 3.0 ± 2.7º. The eyes with extensive misalignment showed significantly greater axial length (p < 0.001), larger corneal diameter (p = 0.034), and flatter corneas (p = 0.044) than those without extensive misalignment. Repositioning surgery to correct toric IOL misorientation was conducted in 9 eyes between 7 and 28 days after cataract surgery. In 2 eyes, repositioning surgery was carried out twice. CONCLUSIONS: In majority of cases plate-haptic multifocal toric IOLs showed satisfactory rotational stability, but extensive misalignment ≥ 45º occurred in 3.3% of cases.


Asunto(s)
Astigmatismo , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares , Agudeza Visual , Estudios Retrospectivos , Tecnología Háptica , Astigmatismo/cirugía , Astigmatismo/complicaciones , Refracción Ocular
14.
Indian J Ophthalmol ; 71(6): 2480-2486, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37322666

RESUMEN

Purpose: To evaluate the clinical outcomes of preloaded toric intraocular lens (IOLs) implantation in eyes undergoing phacoemulsification. Methods: This prospective study included 51 eyes of 51 patients with visually significant cataracts and corneal astigmatism ranging between 0.75 and 5.50 D. All patients underwent phacoemulsification with SupraPhob toric intraocular lens implantation under topical anesthesia. The main outcome measures were uncorrected distance visual acuity (UDVA), residual refractive cylinder, spherical equivalent, and IOL stability at 3 months follow-up. Results: At 3 months, 49% (25/51) of patients had UDVA equal to or better than 20/25 with 100% of eyes achieving better than 20/40. Mean logMAR UDVA improved from 1.02 ± 0.39, preoperatively to 0.11 ± 0.10 at 3 months follow-up (P < 0.001, Wilcoxon signed-rank test). The mean refractive cylinder improved from - 1.56 ± 1.25 D preoperatively to - 0.12 ± 0.31 D at 3 months follow-up (P < 0.001) while the mean spherical equivalent value changed from - 1.93 ± 3.71D preoperatively to - 0.16 ± 0.27D (P = 0.0013). The mean root mean square value for higher order aberrations was 0.30 ± 0.18 µm while the average contrast sensitivity value (Pelli-Robson chart) was 1.56 ± 0.10 log unit, at the final follow-up. The mean IOL rotation at 3 weeks was 1.7 ± 1.61 degrees, which did not change significantly at 3 months (P = 0.988) follow-up. There were no intraoperative or postoperative complications. Conclusion: SupraPhob toric IOL implantation is an effective method for addressing preexisting corneal astigmatism in eyes undergoing phacoemulsification with good rotational stability.


Asunto(s)
Astigmatismo , Extracción de Catarata , Catarata , Lentes Intraoculares , Facoemulsificación , Humanos , Facoemulsificación/métodos , Implantación de Lentes Intraoculares/métodos , Astigmatismo/complicaciones , Estudios Prospectivos , Extracción de Catarata/efectos adversos , Refracción Ocular , Lentes Intraoculares/efectos adversos , Catarata/complicaciones
15.
BMC Ophthalmol ; 23(1): 198, 2023 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-37147624

RESUMEN

BACKGROUND: This retrospective study aimed to compare the outcomes of toric implantable collamer lens (TICL) surgery with those of implantable collamer lens (ICL) implantation combined with limbal relaxing incision (LRI) in patients with low myopia and astigmatism. METHODS: A total of 40 eyes of 28 patients who underwent TICL implantation and 40 eyes of 27 patients who underwent ICL implantation combined with manually LRI between 2021 and 2022 were included. Primary outcomes were manifest sphere and cylinder, intraocular pressure, visual acuity, and astigmatism parameters at 1 day, 1 week, and 1, 3, and 6 months postoperatively. RESULTS: The two surgeries showed comparable effects on manifest sphere and cylinder, intraocular pressure, and visual acuity (all p > 0.1). Surgery-induced astigmatism (SIA) was maintained as stable in the TICL group (1.73 to 1.68, p = 0.420), but was significantly reduced in the ICL/LRI group (1.74 to 1.17, p = 0.001) from preoperative to postoperative 6 months. The TICL group displayed significantly higher SIA and correction index at postoperative 1, 3, and 6 months than the ICL/LRI group (at 6 months: SIA, 1.68 (1.26, 1.96) vs., 1.17 (1.00, 1.64), p = 0.010; CI: 0.98 (0.78, 1.25) vs. 0.80 (0.61, 1.04), p = 0.018). No complications occurred during follow-up. CONCLUSIONS: The effects of ICL/LRI are comparable to those of TICL in correcting myopia. TICL implantation displays better astigmatism correction than ICL/LRI.


Asunto(s)
Astigmatismo , Lentes Intraoculares , Miopía , Lentes Intraoculares Fáquicas , Humanos , Implantación de Lentes Intraoculares , Astigmatismo/cirugía , Astigmatismo/complicaciones , Estudios Retrospectivos , Refracción Ocular , Miopía/cirugía , Miopía/complicaciones
16.
Sci Rep ; 13(1): 7328, 2023 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-37147412

RESUMEN

Pterygium is an abnormal growth of fibrous conjunctival tissue that invades the cornea, resulting in corneal distortion, astigmatism, and increased higher-order aberrations (HOAs). However, few studies have compared eyes with pterygium to normal fellow eyes when interpreting HOAs and there is no study that revealed the effect of the thickness or grading of the pterygium on the change of HOAs. Therefore, we evaluated the effects of nasal pterygium by comparing the normal fellow eye of 59 patients. The pterygium significantly increased with-the-rule corneal astigmatism and corneal irregularity. Trefoils, horizontal coma, and quatrefoils were significantly induced by the pterygium. The grading of the pterygium was not correlated with its characteristics except for the thickness. In multiple linear regression analysis, pterygium-induced corneal astigmatic/irregularity values and horizontal trefoil/quatrefoil were associated with the area of the pterygium. The length of the pterygium was an independent inducer of oblique trefoil/quatrefoil, while horizontal coma was independently associated with both its length and width. The thickness was not correlated with any optical parameters. Together, the results demonstrate that nasal pterygium significantly induces corneal astigmatism, irregularity and some HOAs. These pterygium-associated changes in optical parameters could be predicted by the length, width and area of the pterygium.


Asunto(s)
Astigmatismo , Enfermedades de la Córnea , Pterigion , Humanos , Astigmatismo/complicaciones , Coma/complicaciones , Topografía de la Córnea , Pterigion/complicaciones , Enfermedades de la Córnea/complicaciones , Córnea
17.
Sci Rep ; 13(1): 5389, 2023 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-37012353

RESUMEN

Forceps corneal injuries during infant delivery cause Descemet membrane (DM) breaks, that cause corneal astigmatism and corneal endothelial decompensation. The aim of this study is to characterise corneal higher-order aberrations (HOAs) and corneal topographic patterns in corneal endothelial decompensation due to obstetric forceps injury. This retrospective study included 23 eyes of 21 patients (54.0 ± 9.0 years old) with forceps corneal injury, and 18 healthy controls. HOAs and coma aberrations were significantly larger in forceps injury (1.05 [0.76-1.98] µm, and 0.83 [0.58-1.69], respectively) than in healthy controls (0.10 [0.08-0.11], and 0.06 [0.05-0.07], respectively, both P < 0.0001). Patient visual acuity was positively correlated with coma aberration (rs = 0.482, P = 0.023). The most common topographic patterns were those of protrusion and regular astigmatism (both, six eyes, 26.1%), followed by asymmetric (five eyes, 21.7%), and flattening (four eyes, 17.4%). These results indicate that increased corneal HOAs are associated with decreased visual acuity in corneal endothelial decompensation with DM breaks and corneal topography exhibits various patterns in forceps injury.


Asunto(s)
Astigmatismo , Enfermedades de la Córnea , Lesiones de la Cornea , Aberración de Frente de Onda Corneal , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Forceps Obstétrico/efectos adversos , Coma/complicaciones , Aberración de Frente de Onda Corneal/etiología , Córnea , Enfermedades de la Córnea/complicaciones , Topografía de la Córnea/métodos , Lesiones de la Cornea/etiología , Astigmatismo/complicaciones
18.
Medicina (Kaunas) ; 59(4)2023 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37109616

RESUMEN

In patients with eye surface disorders such as dry eye syndrome or Meibomian gland dysfunction (MGD) it is necessary to improve the tear film condition in order to obtain visual system measurements before cataract surgery. The aim of the project was to analyze the Thermal Pulsation System (TPS) impact on the visual system parameters used in cataract surgery qualification. The study included six patients (11 eyes) with MGD diagnosis. All patients were treated with TPS. The obtained results were compared and used to calculate the power and type of the intraocular lens (IOL). As a treatment result, the power of astigmatism has changed in 64% of the eyes. Planned surgical treatment type has changed in 27% of cases. TPS also affected the cylinder axis in three eyes, which was 27% of cases. Based on the calculations, power of the recommended IOL has changed in five eyes (46%). Stabilization of visual system parameters after TPS allowed to improve the accuracy of the results. It also ensured the proper astigmatism treating method during cataract surgery and allowed selection of the proper IOL power and type.


Asunto(s)
Astigmatismo , Catarata , Lentes Intraoculares , Disfunción de la Glándula de Meibomio , Facoemulsificación , Humanos , Disfunción de la Glándula de Meibomio/cirugía , Astigmatismo/complicaciones , Astigmatismo/cirugía , Glándulas Tarsales , Catarata/complicaciones , Catarata/terapia
19.
Graefes Arch Clin Exp Ophthalmol ; 261(9): 2557-2565, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37004517

RESUMEN

OBJECTIVE: This study aimed to evaluate the visual performance and rotational stability of the multifocal toric intraocular lens in myopes. METHODS: This prospective, observational study included patients with an axial length of ≥24.5 mm and regular corneal astigmatism of >1 diopter who underwent phacoemulsification cataract surgery and implantation of a multifocal toric intraocular lens (AT LISA toric 909M). The visual acuity, defocus curves, residual astigmatism, rotational stability, higher-order aberrations (HOAs), modulation transfer function (MTF), spectacle dependence and patient satisfaction were evaluated 3 months after surgery. RESULTS: Forty-three eyes from 30 patients were enrolled in this study. Postoperatively, uncorrected distance and near visual acuities (logMAR) were 0.09 ± 0.08 (standard deviation, SD) and 0.14 ± 0.08, respectively. The defocus curve analysis provided a bimodal curve showing two peaks of maximum vision at 0.0 D and at -3.0 D defocus level. The multifocal toric intraocular lens showed excellent rotational stability; the mean rotation was 4.02 ± 2.49 (SD) degrees at 3 months postoperatively. Refractive predictability was excellent with a mean spherical equivalent of 0.19 ± 0.37 (SD) diopters (D) and a mean refractive cylinder of -0.34 ± 0.39 (SD) D. CONCLUSIONS: The diffractive multifocal toric intraocular lens, AT LISA toric 909M, provided effective distance and near visual acuities in myopic eyes. It was a predictable and effective device with good rotational stability for the correction of preexisting astigmatism during cataract surgery. In this study, more than 80% of patients achieved spectacle independence.


Asunto(s)
Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares , Astigmatismo/complicaciones , Astigmatismo/cirugía , Estudios Prospectivos , Refracción Ocular , Catarata/complicaciones
20.
Int Ophthalmol ; 43(8): 2917-2924, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36930361

RESUMEN

OBJECTIVE: To evaluate the efficacy of the toric intraocular lens (IOL) and capsular tension ring (CTR) suturing technique in eyes with long axial length (AL) with a high risk of toric IOL rotation. METHODS: This is a retrospective observational case series. The data files of patients who underwent a one-piece acrylic toric IOL (Tecnis Toric IOL and Acrysof IQ Toric IOL) implantation with the toric IOL and CTR suturing technique for cataract and astigmatism or toric IOL repositioning were analyzed. Inclusion criteria were a regular total corneal astigmatism of ≥ 1.5 D and an AL of ≥ 26.0 mm. Preoperative and postoperative astigmatism, uncorrected distance visual acuity (UDVA), IOL rotation, intraoperative, and postoperative complications were evaluated. RESULTS: A total of 30 eyes of 29 patients were included in this study. The mean AL was 27.82 ± 1.53 mm (range, 26.08-31.07). UDVA revealed a statistically significant improvement from 0.84 ± 0.20 logMAR preoperatively to 0.04 ± 0.06 logMAR postoperatively (p < 0.001). The mean preoperative corneal astigmatism was 3.08 ± 1.01 D reduced to the postoperative residual astigmatism of 0.59 ± 0.32 D which was found also statistically significant (p < 0.001). Only 2 eyes (6.2%) had postoperative toric IOL rotation of 5° and 10°, respectively. The mean degree of postoperative rotation was 0.50 ± 2.01. CONCLUSION: This technique provided excellent rotational stability even in eyes with longer AL and did not require additional intervention.


Asunto(s)
Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificación , Humanos , Astigmatismo/cirugía , Astigmatismo/complicaciones , Implantación de Lentes Intraoculares/métodos , Facoemulsificación/métodos , Agudeza Visual , Catarata/complicaciones , Refracción Ocular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...