Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.378
Filtrar
1.
Sci Rep ; 11(1): 13105, 2021 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-34162917

RESUMEN

Although there is a low prevalence of parasitological infections in Europe, the diagnosis of intestinal parasites is still difficult and laborious for microbiology laboratories. Currently, antigen detection assays and molecular biology allow a more accurate diagnosis, but these techniques have limitations as they cannot detect all the possible parasites present in the samples. The objective of the study was to evaluate the accuracy and the usefulness of automated microscopy SediMAX2 (77 Elektronika, Budapest, Hungary) in the detection of parasitic infections from feces. A total of 197 formol-fixed stool samples were processed in parallel by wet mount examination and by SediMAX2. Sensitivities, specificities and predictive values were analyzed, reaching a sensitivity of 89.51% and a specificity of 98.15% and a very good positive predictive value (99.22%). SediMAX2 is a good tool for a reliable diagnosis of intestinal parasitic infections. The rapid processing and the flexibilty of storage of images analyzed make its incorporation into the day to day laboratory routine recommendable.


Asunto(s)
Autoanálisis/métodos , Parasitosis Intestinales/diagnóstico , Estudios Transversales , Heces/parasitología , Humanos , Microscopía/métodos
2.
Sci Rep ; 10(1): 2138, 2020 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-32034174

RESUMEN

The allele ε4 of the apolipoprotein E gene (APOE ε4) is the major genetic risk factor for non-dominantly inherited Alzheimer's Disease (AD). Current techniques for APOE ε4 carriers identification show good accuracy but have several disadvantages that limit its implementation in a clinical laboratory. These include the need for sample preprocessing, poor automation, low throughput, requirement of additional equipment, and high cost. We followed ISO 13485 guidelines to validate the e4Risk test, a new latex-enhanced immunoturbidimetric blood assay for apolipoprotein E4 (ApoE4) determination in human plasma samples. The test showed high performance in terms of lot to lot variability, precision, interferences, reagents stability, prozone, and detectability. Furthermore, diagnostic accuracy is almost equal (99%) to the gold standard, APOE ε4 genotyping by polymerase chain reaction (PCR). Furthermore, we demonstrated that the e4Risk test can be adapted to any clinical chemistry analyzer, including the high throughput analyzers present in most hospitals and clinical laboratories. The e4Risk test versatility, low cost, and easiness provides an excellent solution for APOE ε4 carriers identification using the same blood sample drawn for biochemical diagnostic work-up of AD patients, which can have important advantages for patient stratification in clinical trials, preventative strategies for AD, and clinical assessment of risk for brain amyloidosis.


Asunto(s)
Apolipoproteína E4/sangre , Autoanálisis/métodos , Adolescente , Adulto , Alelos , Enfermedad de Alzheimer/sangre , Enfermedad de Alzheimer/diagnóstico , Enfermedad de Alzheimer/metabolismo , Péptidos beta-Amiloides/sangre , Péptidos beta-Amiloides/metabolismo , Apolipoproteína E4/metabolismo , Encéfalo/metabolismo , Femenino , Genotipo , Humanos , Masculino , Persona de Mediana Edad , Fragmentos de Péptidos/sangre , Fragmentos de Péptidos/metabolismo , Plasma/metabolismo , Adulto Joven
5.
J Vet Intern Med ; 33(1): 167-177, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30511380

RESUMEN

BACKGROUND: Microscopic evaluation of urine is inconsistently performed in veterinary clinics. The IDEXX SediVue Dx® Urine Sediment Analyzer (SediVue) recently was introduced for automated analysis of canine and feline urine and may facilitate performance of urinalyses in practice. OBJECTIVE: Compare the performance of the SediVue with manual microscopy for detecting clinically relevant numbers of cells and 2 crystal types. SAMPLES: Five-hundred thirty urine samples (82% canine, 18% feline). METHODS: For SediVue analysis (software versions [SW] 1.0.0.0 and 1.0.1.3), uncentrifuged urine was pipetted into a cartridge. Images were captured and processed using a convolutional neural network algorithm. For manual microscopy, urine was centrifuged to obtain sediment. To determine sensitivity and specificity of the SediVue compared with manual microscopy, thresholds were set at ≥5/high power field (hpf) for red blood cells (RBC) and white blood cells (WBC) and ≥1/hpf for squamous epithelial cells (sqEPI), non-squamous epithelial cells (nsEPI), struvite crystals (STR), and calcium oxalate dihydrate crystals (CaOx Di). RESULTS: The sensitivity of the SediVue (SW1.0.1.3) was 85%-90% for the detection of RBC, WBC, and STR; 75% for CaOx Di; 71% for nsEPI; and 33% for sqEPI. Specificity was 99% for sqEPI and CaOx Di; 87%-90% for RBC, WBC, and nsEPI; and 84% for STR. Compared to SW1.0.0.0, SW1.0.1.3 had increased sensitivity but decreased specificity. Performance was similar for canine versus feline and fresh versus stored urine samples. CONCLUSIONS AND CLINICAL IMPORTANCE: The SediVue exhibits good agreement with manual microscopy for the detection of most formed elements evaluated, but improvement is needed for epithelial cells.


Asunto(s)
Autoanálisis/veterinaria , Oxalato de Calcio/orina , Microscopía/veterinaria , Estruvita/orina , Orina/citología , Algoritmos , Animales , Autoanálisis/métodos , Gatos/orina , Perros/orina , Recuento de Eritrocitos/métodos , Recuento de Eritrocitos/veterinaria , Recuento de Leucocitos/métodos , Recuento de Leucocitos/veterinaria , Microscopía/métodos , Sensibilidad y Especificidad , Programas Informáticos , Orina/química
6.
Ann Clin Biochem ; 56(1): 123-132, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30068214

RESUMEN

BACKGROUND: Apolipoprotein E-containing high-density lipoprotein shows antiatherogenic properties in vitro. There is a need for a homogeneous assay to determine the concentration of apolipoprotein E-containing high-density lipoprotein for in vivo studies. METHODS: In the proposed homogeneous assay, lipoproteins other than apolipoprotein E-containing high-density lipoprotein were eliminated in the first step. Apolipoprotein E-containing high-density lipoprotein-cholesterol was measured in the second step. The control study used a 13% polyethylene glycol precipitation assay (control assay). RESULTS: The homogeneous assay showed good performance in validation studies. In subjects with normal liver function ( n = 78), a significant correlation was found between the control assay and the homogeneous assay ( r = 0.824). Serum apolipoprotein E-containing high-density lipoprotein cholesterol concentrations, determined by the control assay and the homogeneous assay, respectively, were 0.05 (0.04-0.10) (median [25th-75th percentile]) mmol/L and 0.10 (0.06-0.13) mmol/L for healthy individuals ( n = 12), and 0.03 (0.01-0.13) mmol/L and 0.02 (0.01-0.02) mmol/L for patients with cholestasis ( n = 6). The results indicate that the homogeneous assay recovers cholesterol contained in physiological apolipoprotein E-containing high-density lipoprotein, but not in pathological apolipoprotein E-containing high-density lipoprotein from cholestatic patients. CONCLUSIONS: The proposed two-step homogeneous assay enables selective measurement of physiological apolipoprotein E-containing high-density lipoprotein cholesterol in common autoanalysers. This assay might uncover a role for apolipoprotein E-containing high-density lipoprotein in physiological conditions.


Asunto(s)
Apolipoproteínas E/sangre , Análisis Químico de la Sangre/métodos , Lipoproteínas HDL/sangre , Adulto , Anciano , Autoanálisis/métodos , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad
7.
Vet Clin Pathol ; 47(3): 415-424, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29989207

RESUMEN

BACKGROUND: Point-of-care analyzers can provide a rapid turnaround time for critical blood test results. Agreement between the Enterprise Point-of-Care (EPOC) and bench-top laboratory analyzers is important to determine the clinical reliability of the EPOC. OBJECTIVES: The aim of the study was (1) to evaluate the precision (repeatability) of blood gas values measured by the EPOC and (2) to determine the level of agreement between the EPOC and Nova Critical Care Express (Nova CCX) for the assessment of arterial pH, blood gases, and electrolyte variables in canine and equine blood. METHODS: Arterial blood samples from dogs were analyzed on the EPOC and Nova CCX analyzers to determine precision and agreement of pH, PaCO2 , PaO2 , and HCT. The same analytes plus Na+ , K- , and Cl- were analyzed for agreement using equine blood. Statistical analyses included assessment of precision using the coefficient of variation (CV%), and agreement using the Deming regression, Pearson correlation, and Bland-Altman plots. RESULTS: Both analyzers provided precise results of pH, PaCO2 , PaO2, and HCT, meeting CV% quality requirement values. In both species, Deming regression results were acceptable and correlation values were above 0.93 for arterial pH and blood gases, but lower for sodium and chloride. Bland-Altman plots demonstrated varying degrees of bias, but good agreement between the 2 analyzers was seen when arterial blood gases and electrolytes were measured, except for PaCO2 and Cl-. CONCLUSION: The EPOC analyzer provides consistent, reliable results for canine arterial blood gas values and for equine arterial blood gas and electrolyte values. Cl- results could be acceptable with the application of a correction factor, but the PaCO2 results were more variable.


Asunto(s)
Autoanálisis/veterinaria , Análisis de los Gases de la Sangre/veterinaria , Perros/sangre , Electrólitos/sangre , Caballos/sangre , Animales , Autoanálisis/instrumentación , Autoanálisis/métodos , Análisis de los Gases de la Sangre/instrumentación , Análisis de los Gases de la Sangre/métodos , Recolección de Muestras de Sangre/veterinaria , Concentración de Iones de Hidrógeno , Sistemas de Atención de Punto , Reproducibilidad de los Resultados
8.
PLoS One ; 13(6): e0198695, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29912907

RESUMEN

BACKGROUND: Meningitis caused by Mycobacterium tuberculosis is a major cause of morbidity and mortality worldwide. We evaluated the performance of cerebrospinal fluid (CSF) testing with the GeneXpert MTB/RIF assay versus traditional approaches for diagnosing tuberculosis meningitis (TBM). METHODS: Patients were adults (n = 37) presenting with suspected TBM to the Hospital Nacional Dos de Mayo, Lima, Peru, during 12 months until 1st January 2015. Each participant had a single CSF specimen that was divided into aliquots that were concurrently tested for M. tuberculosis using GeneXpert, Ziehl-Neelsen smear and culture on solid and liquid media. Drug susceptibility testing used Mycobacteria Growth Indicator Tube (MGIT 960) and the proportions method. RESULTS: 81% (30/37) of patients received a final clinical diagnosis of TBM, of whom 63% (19/30, 95% confidence intervals, CI: 44-80%) were HIV-positive. 22% (8/37, 95%CI: 9.8-38%), of patients had definite TBM. Because definite TBM was defined by positivity in any laboratory test, all laboratory tests had 100% specificity. Considering the 30 patients who had a clinical diagnosis of TBM: diagnostic sensitivity was 23% (7/30, 95%CI: 9.9-42%) for GeneXpert and was the same for all culture results combined; considerably greater than 7% (2/30, 95%CI: 0.82-22%) for microscopy; whereas all laboratory tests had poor negative predictive values (20-23%). Considering only the 8 patients with definite TBM: diagnostic sensitivity was 88% (7/8, 95%CI: 47-100%) for GeneXpert; 75% (6/8, 95%CI: 35-97%) for MGIT culture or LJ culture; 50% (4/8, 95%CI 16-84) for Ogawa culture and 25% (2/8, 95%CI: 3.2-65%) for microscopy. GeneXpert and microscopy provided same-day results, whereas culture took 20-56 days. GeneXpert provided same-day rifampicin-susceptibility results, whereas culture-based testing took 32-71 days. 38% (3/8, 95%CI: 8.5-76%) of patients with definite TBM with data had evidence of drug-resistant TB, but 73% (22/30) of all clinically diagnosed TBM (definite, probable, and possible TBM) had no drug-susceptibility results available. CONCLUSIONS: Compared with traditional culture-based methods of CSF testing, GeneXpert had similar yield and faster results for both the detection of M. tuberculosis and drug-susceptibility testing. Including use of the GeneXpert has the capacity to improve the diagnosis of TBM cases.


Asunto(s)
Tuberculosis Meníngea/diagnóstico , Adolescente , Adulto , Antituberculosos/uso terapéutico , Autoanálisis/métodos , Líquido Cefalorraquídeo/microbiología , Técnicas de Laboratorio Clínico/métodos , Farmacorresistencia Bacteriana , Femenino , Humanos , Masculino , Pruebas de Sensibilidad Microbiana/métodos , Persona de Mediana Edad , Mycobacterium tuberculosis , Reproducibilidad de los Resultados , Rifampin/uso terapéutico , Sensibilidad y Especificidad , Tuberculosis Meníngea/líquido cefalorraquídeo , Tuberculosis Meníngea/tratamiento farmacológico , Tuberculosis Resistente a Múltiples Medicamentos/diagnóstico , Tuberculosis Resistente a Múltiples Medicamentos/tratamiento farmacológico , Adulto Joven
9.
Zool Res ; 39(2): 123-126, 2018 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-29515094

RESUMEN

With the wide application of DNA sequencing technology, DNA sequences are still increasingly generated through the Sanger sequencing platform. SeqMan (in the LaserGene package) is an excellent program with an easy-to-use graphical user interface (GUI) employed to assemble Sanger sequences into contigs. However, with increasing data size, larger sample sets and more sequenced loci make contig assemble complicated due to the considerable number of manual operations required to run SeqMan. Here, we present the 'autoSeqMan' software program, which can automatedly assemble contigs using SeqMan scripting language. There are two main modules available, namely, 'Classification' and 'Assembly'. Classification first undertakes preprocessing work, whereas Assembly generates a SeqMan script to consecutively assemble contigs for the classified files. Through comparison with manual operation, we showed that autoSeqMan saved substantial time in the preprocessing and assembly of Sanger sequences. We hope this tool will be useful for those with large sample sets to analyze, but with little programming experience. It is freely available at https://github.com/ Sun-Yanbo/autoSeqMan.


Asunto(s)
Análisis de Secuencia de ADN , Animales , Autoanálisis/instrumentación , Autoanálisis/métodos , Mapeo Contig , Secuenciación de Nucleótidos de Alto Rendimiento/instrumentación , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Análisis de Secuencia de ADN/instrumentación , Análisis de Secuencia de ADN/métodos , Interfaz Usuario-Computador
10.
Clin Toxicol (Phila) ; 56(4): 237-244, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28814126

RESUMEN

AIM: Nitromethane, found in fuels used for short distance racing, model cars, and model airplanes, produces a falsely elevated serum creatinine with standard creatinine analysis via the Jaffé method. Erroneous creatinine elevation often triggers extensive testing, leads to inaccurate diagnoses, and delayed or inappropriate medical interventions. Multiple reports in the literature identify "enzymatic assays" as an alternative method to detect the true value of creatinine, but this ambiguity does not help providers translate what type of enzymatic assay testing can be done in real time to determine if there is indeed false elevation. METHODS: We report seven cases of ingested nitromethane where creatinine was determined via Beckman Coulter® analyser using the Jaffé method, Vitros® analyser, or i-Stat® point-of-care testing. Nitromethane was detected and semi-quantified using a common clinical toxic alcohol analysis method, and quantified by headspace-gas chromatography-mass spectrometry. RESULTS: When creatinine was determined using i-Stat® point-of-care testing or a Vitros® analyser, levels were within the normal range. Comparatively, all initial creatinine levels obtained via the Jaffé method were elevated. Nitromethane concentrations ranged from 42 to 310 µg/mL. CONCLUSIONS: These cases demonstrate reliable assessment of creatinine through other enzymatic methods using a Vitros® analyser or i-STAT®. Additionally, nitromethane is detectable and quantifiable using routine alcohols gas chromatography analysis and by headspace-gas chromatography-mass spectrometry.


Asunto(s)
Creatinina/sangre , Metano/análogos & derivados , Nitroparafinas/sangre , Adolescente , Adulto , Autoanálisis/métodos , Pruebas de Enzimas/métodos , Reacciones Falso Positivas , Femenino , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Masculino , Metano/sangre , Metano/envenenamiento , Nitroparafinas/envenenamiento , Sistemas de Atención de Punto , Adulto Joven
11.
Clin Microbiol Infect ; 23(12): 948-951, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28487166

RESUMEN

OBJECTIVE: We adapted the BD Max GBS assay, an automated platform for the detection of Group B streptococcus (GBS) DNA in vaginal-rectal swab specimens after LIM broth enrichment, to directly detect GBS in specimens collected using cellular foam swabs in Amies liquid medium. We compared the BD Max GBS assay performance to that of enriched culture and the BD GeneOhm StrepB assay. METHODS: Seventy-two reference vaginal-rectal specimens were employed to determine the limit of GBS detection and the preferred test volume for direct detection of GBS. A total of 304 clinical specimens were then tested by the optimized BD Max GBS assay, both by direct testing and following broth enrichment. RESULTS: The limit of GBS detection was 75 CFU/mL and the preferred test volume was 100 µL. Of 304 clinical specimens tested, GBS was detected in 62 specimens by enriched culture (20.4%); 61 of these yielded GBS by the BD Max GBS assay when performed directly from the liquid swab (sensitivity 98.4%). All 242 culture-negative specimens also yielded negative results by the BD Max GBS assay (specificity 100%). When this assay was performed following broth enrichment, GBS was detected in all 62 culture-positive specimens (100% sensitivity). The sensitivity and specificity of the BD GeneOhm StrepB assay was 90.3% and 99%, respectively. CONCLUSIONS: The BD Max GBS assay is highly sensitive, requires minimal technical skill with <2 min required to set-up, and results are available in under 80 min (versus 24-48 h for culture). It is configured for 'on demand' testing and vaginal-rectal specimens can be rapidly screened for GBS without the need for enrichment. The results obtained in this study demonstrate that rapid GBS screening using the BD Max GBS assay at the time of delivery is a viable alternative to the current recommended screening at 35-37 weeks of gestation with pre-enrichment testing methods.


Asunto(s)
Recto/microbiología , Infecciones Estreptocócicas/diagnóstico , Streptococcus agalactiae , Vagina/microbiología , Autoanálisis/métodos , ADN Bacteriano/genética , Femenino , Humanos , Embarazo , Complicaciones Infecciosas del Embarazo/diagnóstico , Complicaciones Infecciosas del Embarazo/microbiología , Manejo de Especímenes/métodos , Streptococcus agalactiae/genética
12.
PLoS One ; 11(3): e0150576, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26930553

RESUMEN

BACKGROUND: Enteric fever remains an important cause of morbidity in many low-income countries and Salmonella Paratyphi A has emerged as the aetiological agent in an increasing proportion of cases. Lack of adequate diagnostics hinders early diagnosis and prompt treatment of both typhoid and paratyphoid but development of assays to identify paratyphoid has been particularly neglected. Here we describe the development of a rapid and sensitive blood culture PCR method for detection of Salmonella Paratyphi A from blood, potentially allowing for appropriate diagnosis and antimicrobial treatment to be initiated on the same day. METHODS: Venous blood samples from volunteers experimentally challenged orally with Salmonella Paratyphi A, who subsequently developed paratyphoid, were taken on the day of diagnosis; 10 ml for quantitative blood culture and automated blood culture, and 5 ml for blood culture PCR. In the latter assay, bacteria were grown in tryptone soy broth containing 2.4% ox bile and micrococcal nuclease for 5 hours (37°C) before bacterial DNA was isolated for PCR detection targeting the fliC-a gene of Salmonella Paratyphi A. RESULTS: An optimized broth containing 2.4% ox bile and micrococcal nuclease, as well as a PCR test was developed for a blood culture PCR assay of Salmonella Paratyphi A. The volunteers diagnosed with paratyphoid had a median bacterial burden of 1 (range 0.1-6.9) CFU/ml blood. All the blood culture PCR positive cases where a positive bacterial growth was shown by quantitative blood culture had a bacterial burden of ≥ 0.3 CFU/ ml blood. The blood culture PCR assay identified an equal number of positive cases as automated blood culture at higher bacterial loads (≥0.3 CFU/ml blood), but utilized only half the volume of specimens. CONCLUSIONS: The blood culture PCR method for detection of Salmonella Paratyphi A can be completed within 9 hours and offers the potential for same-day diagnosis of enteric fever. Using 5 ml blood, it exhibited a lower limit of detection equal to 0.3 CFU/ml blood, and it performed at least as well as automated blood culture at higher bacterial loads (≥0.3 CFU/ml blood) of clinical specimens despite using half the volume of blood. The findings warrant its further study in endemic populations with a potential use as a novel diagnostic which fills the present gap of paratyphoid diagnostics.


Asunto(s)
Fiebre Paratifoidea/diagnóstico , Reacción en Cadena de la Polimerasa/métodos , Salmonella paratyphi A , Autoanálisis/métodos , ADN Bacteriano/genética , Humanos , Fiebre Paratifoidea/sangre , Salmonella paratyphi A/genética , Sensibilidad y Especificidad
13.
Invest Ophthalmol Vis Sci ; 56(11): 6701-8, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26469755

RESUMEN

PURPOSE: TUNEL assay is widely used to evaluate cell death. Quantification of TUNEL-positive (TUNEL+) cells in tissue sections is usually performed manually, ideally by two masked observers. This process is time consuming, prone to measurement errors, and not entirely reproducible. In this paper, we describe an automated quantification approach to address these difficulties. METHODS: We developed an ImageJ macro to quantitate cell death by TUNEL assay in retinal cross-section images. The script was coded using IJ1 programming language. To validate this tool, we selected a dataset of TUNEL assay digital images, calculated layer area and cell count manually (done by two observers), and compared measurements between observers and macro results. RESULTS: The automated macro segmented outer nuclear layer (ONL) and inner nuclear layer (INL) successfully. Automated TUNEL+ cell counts were in-between counts of inexperienced and experienced observers. The intraobserver coefficient of variation (COV) ranged from 13.09% to 25.20%. The COV between both observers was 51.11 ± 25.83% for the ONL and 56.07 ± 24.03% for the INL. Comparing observers' results with macro results, COV was 23.37 ± 15.97% for the ONL and 23.44 ± 18.56% for the INL. CONCLUSIONS: We developed and validated an ImageJ macro that can be used as an accurate and precise quantitative tool for retina researchers to achieve repeatable, unbiased, fast, and accurate cell death quantitation. We believe that this standardized measurement tool could be advantageous to compare results across different research groups, as it is freely available as open source.


Asunto(s)
Muerte Celular , Retina/patología , Animales , Autoanálisis/métodos , Recuento de Células/métodos , Etiquetado Corte-Fin in Situ , Ratones , Ratones Endogámicos C57BL , Microscopía Fluorescente , Retina/citología
14.
Clin Chem Lab Med ; 53 Suppl 2: s1509-11, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26057217

RESUMEN

Automated urinalysis devices are reproducible, accurate and faster than the standard manual microscopy. Economic analysis has shown that decreases in turn-around-time and labour cost savings offered by these devices make them more economic than manual microscopy.


Asunto(s)
Urinálisis/instrumentación , Autoanálisis/economía , Autoanálisis/instrumentación , Autoanálisis/métodos , Análisis Costo-Beneficio , Humanos , Laboratorios/economía , Laboratorios/normas , Microscopía , Urinálisis/economía , Urinálisis/normas
15.
J Vet Med Sci ; 77(8): 977-9, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25787927

RESUMEN

The aim of the present study was to compare the ability of the commercially available portable test system (PTS(TM)) to detect endotoxin activity in bovine serum, with that of the traditional LAL-kinetic turbidimetric (KT) and chromogenic (KC) assays. Prior to testing, serum samples, which were obtained from endotoxin-challenged cattle, were diluted 1:20 in endotoxin-free water and heated to 80°C for 10 min. The performance of the PTS(TM) was not significantly different from that of the traditional LAL-based assays. The results using PTS(TM) correlated with those using KT (r(2)=0.963, P<0.001) or KC assays (r(2)=0.982, P<0.001). Based on these findings, the PTS(TM) could be applied as a simplified system to assess endotoxin activity in bovine serum.


Asunto(s)
Autoanálisis/veterinaria , Bovinos/sangre , Endotoxinas/sangre , Animales , Autoanálisis/instrumentación , Autoanálisis/métodos , Bovinos/microbiología , Nefelometría y Turbidimetría/veterinaria , Sistemas de Atención de Punto
16.
J Clin Lab Anal ; 29(2): 146-52, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24797498

RESUMEN

BACKGROUND: Fourth-generation human immunodeficiency virus (HIV) screening assays have been used in many laboratories. The Elecsys® HIV combi PT assay is a new kind of fourth-generation HIV screening assay developed to allow earlier detection of seroconversion. METHODS: A total of 271,845 routine specimens were detected using the Elecsys® HIV combi assay and Elecsys® HIV combi PT assay from September 2010 to December 2012 in a large university hospital. Repeatedly, reactive screening samples were confirmed according to recommended confirmatory algorithms. RESULTS: The false-positive rate and positive predictive value (PPV) of two assays are 0.08 and 78.35%, respectively, for the Elecsys® HIV combi assay and 0.07 and 82.21% for the Elecsys® HIV combi PT assay. Ninety-four percent cases with cutoff index ratio <15.0 were false-positive. When we set the specificity as 95.0 and 99.0%, PPV could increase to 98.7, 99.6, 98.8, and 99.7%, and sensitivity reduced to 99.2, 98.4, 98.5, and 96.8% for the Elecsys® HIV combi assay and the Elecsys® HIV combi PT assay, respectively. CONCLUSIONS: The Elecsys® HIV combi PT assay shows a better performance in specificity than the Elecsys® HIV combi assay. Most weakly reactive results were false-positive, this means it still need to be improved and it will need laboratory personnel to communicate with the clinical doctor and patients more properly about the result of the assay.


Asunto(s)
VIH/aislamiento & purificación , Hospitales , Inmunoensayo/métodos , Autoanálisis/métodos , China , Reacciones Falso Positivas , Infecciones por VIH/diagnóstico , Infecciones por VIH/virología , VIH-1/aislamiento & purificación , Humanos , Tamizaje Masivo , Control de Calidad , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad
17.
Micron ; 61: 1-8, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24792441

RESUMEN

In this paper automatic leukocyte segmentation in pathological blood cell images is proposed using intuitionistic fuzzy and interval Type II fuzzy set theory. This is done to count different types of leukocytes for disease detection. Also, the segmentation should be accurate so that the shape of the leukocytes is preserved. So, intuitionistic fuzzy set and interval Type II fuzzy set that consider either more number of uncertainties or a different type of uncertainty as compared to fuzzy set theory are used in this work. As the images are considered fuzzy due to imprecise gray levels, advanced fuzzy set theories may be expected to give better result. A modified Cauchy distribution is used to find the membership function. In intuitionistic fuzzy method, non-membership values are obtained using Yager's intuitionistic fuzzy generator. Optimal threshold is obtained by minimizing intuitionistic fuzzy divergence. In interval type II fuzzy set, a new membership function is generated that takes into account the two levels in Type II fuzzy set using probabilistic T co norm. Optimal threshold is selected by minimizing a proposed Type II fuzzy divergence. Though fuzzy techniques were applied earlier but these methods failed to threshold multiple leukocytes in images. Experimental results show that both interval Type II fuzzy and intuitionistic fuzzy methods perform better than the existing non-fuzzy/fuzzy methods but interval Type II fuzzy thresholding method performs little bit better than intuitionistic fuzzy method. Segmented leukocytes in the proposed interval Type II fuzzy method are observed to be distinct and clear.


Asunto(s)
Lógica Difusa , Leucocitos/ultraestructura , Autoanálisis/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Recuento de Leucocitos/métodos
18.
Klin Lab Diagn ; 59(11): 37-9, 2014 Nov.
Artículo en Ruso | MEDLINE | ID: mdl-25850244

RESUMEN

The volume of urine of high power field of analyzer Iris IQ 200 TM was identified according standard of stabilizing erythrocytes and amounted up to 0.18 mkl. The amount of urine corpuscles detected by analyzer in this volume corresponds to amount of urine corpuscles under microscopy of sediment often times concentrated urine at thickness of preparation in 0.1 mm, under microscope with objective x40 and ocular 10/18. The count of corpuscles by analyzer in 1 mkl of urine is the most objective and convenient technique for quantitative evaluation of urine corpuscles.


Asunto(s)
Autoanálisis/métodos , Urinálisis/métodos , Recuento de Células , Eritrocitos/citología , Humanos , Leucocitos/citología , Microscopía
19.
Zhonghua Xue Ye Xue Za Zhi ; 34(7): 629-31, 2013 Jul.
Artículo en Chino | MEDLINE | ID: mdl-23906462

RESUMEN

OBJECTIVE: To evaluate the application of XT-4000i automatic blood cell analyzer in white cell count and classification of cerebrospinal fluid (CSF). METHODS: The fluid model of XT-4000i automatic blood cell analyzer was directly used to detect the white cell count and classification in 200 samples of CSF, and compared with the results obtained by manually microscopic counting method. White blood cell classification was performed by manual method under microscope with Wright's staining,and instrumental method with fluorescence staining and flow cytometry. RESULTS: There is no statistical difference between instrumental and manual method in detecting the absolute counting of WBC, RBC, mononuclear cell and multinucleate cells (P>0.05), and there is a good correlation between the two methods (r=0.987, 0.999, 0.981 and 0.983 for WBC, RBC, mononuclear cell and multinucleate cell counts). Tumor cells in the samples with high fluorescent staining by instrumental method can be identified with Wright's staining by microscope method, which were consistent with the clinical diagnosis. CONCLUSION: The fluid model of XT-4000i automatic blood cell analyzer was rapid and accurate in CSF white cell count and classification,and it also can provide preliminary information for tumor cells screening. The fluid model of XT-4000i automatic blood cell analyzer in white cell count and classification of CSF has the value of popularization in clinical application.


Asunto(s)
Autoanálisis , Recuento de Leucocitos/instrumentación , Recuento de Leucocitos/métodos , Leucocitos/clasificación , Autoanálisis/instrumentación , Autoanálisis/métodos , Líquido Cefalorraquídeo/citología , Humanos
20.
Res Vet Sci ; 94(3): 440-5, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23360686

RESUMEN

Two dipsticks developed for human use were evaluated for routine urinalysis and for detection of proteinuria in dogs (n=101), cats (n=50) and cattle (n=100). The aims were to determine their diagnostic usefulness in dogs, cats and cattle and to compare automated versus visual methods of reading. Results obtained with automated reading correlated better with reference methods than visual reading. Correlation with the reference methods was good to excellent for automated estimation of creatinine (dog: r(s)=0.86, cat: r(s)=0.83, cattle: r(s)=0.87) and pH (dog: r(s)=0.96, cat: r(s)=0.91, cattle: rs=0.94). The correlation was good for protein (dog: r(s)=0.88, cat: r(s)=0.91), glucose (cat: r(s)=0.83) and urine protein:creatinine (UPC) ratio (dog: r(s)=0.75, cat: r(s)=0.89). Estimation of proteinuria in cattle and pyuria in cats lacked specificity and detection of isosthenuria lacked sensitivity in all species. Semiquantitative estimation of UPC ratio was specific (100% and 91.2% at a cut-off of 0.2 in cats and 0.4 in dogs, respectively).


Asunto(s)
Autoanálisis/veterinaria , Enfermedades de los Gatos/orina , Enfermedades de los Bovinos/orina , Enfermedades de los Perros/orina , Proteinuria/veterinaria , Tiras Reactivas , Animales , Autoanálisis/métodos , Enfermedades de los Gatos/diagnóstico , Gatos/orina , Bovinos/orina , Enfermedades de los Bovinos/diagnóstico , Creatinina/orina , Enfermedades de los Perros/diagnóstico , Perros/orina , Femenino , Masculino , Proteinuria/diagnóstico , Proteinuria/orina , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Gravedad Específica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...