1.
Port J Card Thorac Vasc Surg ; 31(1): 12-16, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38743522

RESUMEN

There has been a worldwide rapid adoption of transcatheter aortic valve replacement (TAVR) as an alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Currently, more TAVR explants with SAVRs are performed than TAVR-in TAV. TAVR explantation is a technically hazardous procedure mainly due to significant aortic neo-endothelialization which incorporates the TAVR valve. Surgical techniques for TAVR explantation are not well established and surgeon experience at present is limited. In this manuscript, we describe our technique for surgical explantation of transcatheter aortic bioprosthesis. Familiarity with the procedure and its clinical implications is essential for all cardiac surgeons.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Remoción de Dispositivos , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Remoción de Dispositivos/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación
2.
J Cardiothorac Surg ; 19(1): 191, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38589959

RESUMEN

BACKGROUND: Fungal endocarditis is a rare but serious condition associated with high mortality rates. Various predisposing factors contribute to its occurrence, such as underlying cardiac abnormalities, cardiac surgeries, prosthetic cardiac devices, and central venous catheters. Diagnosing fungal endocarditis, particularly Aspergillus, poses challenges, often complicated by negative blood cultures. CASE PRESENTATION: This report details a case of extensive ascending aorta involvement in Aspergillus endocarditis (AE) in a 24-year-old man with a history of bioprosthesis aortic valve replacement (AVR). Three months post-AVR, he presented with pericardial effusion and aortic rupture, leading to a redo biological valved conduit aortic root replacement (Bentall surgery). Despite the intervention, the tubular graft exhibited extensive Aspergillus involvement, resulting in graft disruption and significant peri-aortic infection. A second redo procedure involving aortic homograft root replacement was performed. Unfortunately, the patient succumbed two days after the surgery. CONCLUSION: A combined approach of medical and surgical therapies is recommended to manage fungal endocarditis. Despite efforts, the mortality rate associated with Aspergillus endocarditis remains unacceptably high, with no significant difference observed between combination therapy and antifungal treatment alone. Further research is essential to explore novel therapeutic strategies and improve outcomes for patients with this challenging condition.


Asunto(s)
Bioprótesis , Endocarditis , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Micosis , Humanos , Masculino , Adulto Joven , Aorta/cirugía , Aorta Torácica/cirugía , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Endocarditis/diagnóstico , Endocarditis/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas/efectos adversos
3.
J Cardiothorac Surg ; 19(1): 219, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627820

RESUMEN

OBJECTIVES: Thrombocytopenia following Perceval aortic valve replacement has been described previously with variable outcome. Studies have lacked a robust analysis of platelet fluctuation and factors affecting it. We aimed to statistically describe the trend in thrombocyte variability as compared with conventional aortic valve replacement, and to assess predictors as well as impact on associated outcomes. METHODS: One hundred consecutive patients with first-time Perceval were retrospectively compared to 219 patients after Perimount Magna Ease valve replacement. The primary outcome was the serial thrombocyte count on day 0-6. Generalized estimating equations were used to analyse the data using fixed-effect models: for the effect of the post-operative day on platelet count, and random-effect models estimating both time-variant (platelets) and time in-variant variables (valve type, age, LV function, pre-op platelet level). RESULTS: Perceval patients were older (72 ± 1 vs 68 ± 1 years, p < 0.01) with higher NYHA status (3(2-3) vs 2(1-2), p < 0.001). Mean platelet count in the sutureless group was lowest on day 2 (91.9 ± 31.6 vs 121.7 ± 53.8 × 103 µl-1), and lower on day 4 (97.9 ± 44) and 6 (110.6 ± 61) compared to the conventional group (157.2 ± 60 and 181.7 ± 79) but did not result in a higher number of transfusions, bleeding or longer hospital stay (p > 0.05). Reduced platelet count was a strong predictor of red cell transfusion in the conventional (p = 0.016), but not in the sutureless group (p = 0.457). Age (Coef -1.025, 95%CI-1.649--0.401, p < 0.001) and CPB-time (Coef 0.186, 95%CI-0.371--0.001, p = 0.048) were predictors for lower platelet levels. CONCLUSION: Considering the older patient profile treated with Perceval, postoperative thrombocytopenia does not impact on outcome in terms of transfusions, complications or hospital stay.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombocitopenia , Humanos , Válvula Aórtica/cirugía , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Bioprótesis/efectos adversos , Diseño de Prótesis , Prótesis Valvulares Cardíacas/efectos adversos , Trombocitopenia/etiología , Factores de Riesgo , Progresión de la Enfermedad
4.
Echocardiography ; 41(4): e15804, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38578295

RESUMEN

A 60-year-old man presented with breathlessness. Nearly four decades previously, he had required three operations for Staphylococcus aureus infective endocarditis of the tricuspid valve and had received a bioprosthetic valve. He had critical tricuspid bioprosthesis stenosis which was treated successfully by valve-in-valve transcatheter tricuspid valve replacement using a balloon-expandable transcatheter heart valve. One year after intervention, the patient is well with no tricuspid valve stenosis or regurgitation.


Asunto(s)
Bioprótesis , Endocarditis Bacteriana , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Estenosis de la Válvula Tricúspide , Masculino , Humanos , Persona de Mediana Edad , Adulto , Bioprótesis/efectos adversos , Constricción Patológica , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Estenosis de la Válvula Tricúspide/diagnóstico por imagen , Estenosis de la Válvula Tricúspide/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/cirugía , Resultado del Tratamiento , Diseño de Prótesis , Falla de Prótesis
5.
BMJ Case Rep ; 17(4)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38684360

RESUMEN

A patient in his 60s with a bioprosthetic aortic and mitral valve replacement presented with dyspnoea, tiredness and dizziness 2 years postoperatively. Transthoracic echocardiography showed mitral valve stenosis and increased pulmonary artery pressure suggesting bioprosthetic valve failure. Cardiac CT confirmed the diagnosis of bioprosthetic mitral valve thrombosis. Treatment with anticoagulation resulted in a remarkable improvement of the valve area and gradient and complete resolution of the thrombus. Herein, we report a case of rare bioprosthetic mitral valve thrombosis.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Válvula Mitral , Trombosis , Tomografía Computarizada por Rayos X , Humanos , Masculino , Bioprótesis/efectos adversos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/tratamiento farmacológico , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/diagnóstico por imagen , Anticoagulantes/uso terapéutico , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Persona de Mediana Edad , Falla de Prótesis
6.
Kyobu Geka ; 77(3): 206-209, 2024 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-38465492

RESUMEN

We report a case of bioprosthetic valve dysfunction and acute aortic valve regurgitation. The case was a 75-year-old female who had sudden onset chest pain. ST-segment depression in several leads on electrocardiogram( ECG) suggested acute coronary syndrome. Coronary angiography showed no significant stenosis in coronary arteries. Transesophageal echocardiography revealed severe aortic regurgitation, suggesting that angina was caused by myocardial ischemia associated with acute aortic regurgitation. She was diagnosed as having bioprosthetic valve dysfunction, and underwent redo aortic valve replacement. One leaflet of the bioprosthetic valve was torn along the stent post and caused bioprosthetic valve dysfunction. Failed bioprosthetic valve was removed and replaced by a mechanical valve.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Femenino , Humanos , Anciano , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Tórax , Prótesis Valvulares Cardíacas/efectos adversos , Dolor en el Pecho/etiología , Bioprótesis/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
7.
BMJ Case Rep ; 17(2)2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38395470

RESUMEN

The Trifecta tissue valve (Abbott, Illinois, USA) is an externally mounted bovine pericardial aortic valve (AV) prosthesis with adequate haemodynamic performance and better early results than another option. However, concerns have been raised about its durability. Recently, reports have emerged about an increased incidence of early structural valve failure after Trifecta implantation, where leaflet tear(s) with dehiscence along the stent post was the primary mode of early failure. In this article, we present the case of a patient in her 70s, 7 years after AV replacement with a Trifecta valve, who developed progressive dyspnoea. Physical examination revealed signs of chronic severe aortic regurgitation (AR). The initial transthoracic echocardiogram showed severe transvalvular AR, but the aetiology could not be determined. Cardiac computed tomography (CT) revealed a flail non-coronary cusp of the Trifecta bioprosthetic valve without vegetation. After discussion, we concluded that our patient was suitable for valve-in-valve transcatheter aortic valve replacement (ViV TAVR).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Animales , Bovinos , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Falla de Prótesis , Bioprótesis/efectos adversos , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía
8.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38331412

RESUMEN

OBJECTIVES: While current data show a clear trend towards the use of bioprosthetic valves during aortic valve replacement (AVR), durability of bioprosthetic valves remains the most important concern. We conducted a 1st systematic review of all available evidence that analysed early and mid-term outcomes after AVR using the Inspiris RESILIA™ bioprosthesis. METHODS: A systematic literature search was performed to identify all relevant studies evaluating early and mid-term outcomes after AVR using the Inspiris RESILIA bioprosthesis and including at least 20 patients with no restriction on the publication date. Subgroup meta-analysis was performed to compare Inspiris RESILIA and PERIMOUNT Magna Ease bioprosthesis and to pool the early postoperative mortality and stroke rates. RESULTS: A total of 416 studies were identified, of which 15 studies met the eligibility criteria. The studies included a total of 3202 patients with an average follow-up of up to 5.3 years. The average age of patients across the studies was 52.2-75.1 years. Isolated AVR was performed in 39.0-86.4% of patients. In-hospital or 30-day postoperative mortality was 0-2.8%. At the mid-term follow-up, freedom from all-cause mortality was up to 85.4%. Among studies with mid-term follow-up, trace/mild paravalvular leak was detected in 0-3.0%, while major paravalvular leak was found only in up to 2.0% of patients. No statistically significant differences in terms of mortality (P = 0.98, odds ratio 1.02, 95% confidence interval 0.36-2.83) and stroke (P = 0.98, odds ratio 1.01, 95% confidence interval 0.38-2.73) between the Inspiris RESILIA bioprosthesis and PERIMOUNT Magna Ease bioprosthesis were observed in the subgroup meta-analysis. CONCLUSIONS: Mid-term data on the safety and haemodynamic performance of the novel aortic bioprosthesis are encouraging. Further comparative studies with other bioprostheses and longer follow-up are still required to endorse durability and safety of the novel bioprosthesis.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Humanos , Persona de Mediana Edad , Anciano , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Diseño de Prótesis , Resultado del Tratamiento , Estudios Retrospectivos
9.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38305431

RESUMEN

OBJECTIVES: This nationwide retrospective cohort study assessed the impact of the explanted valve type on reoperative outcomes in aortic valve surgery within the UK over a 23-year period. METHODS: Data were sourced from the National Institute for Cardiovascular Outcomes Research (NICOR) database. All patients undergoing first-time isolated reoperative aortic valve replacement between 1996 and 2019 in the UK were included. Concomitant procedures, homograft implantation or aortic root enlargement were excluded. Propensity score matching was utilized to compare outcomes and risk factors for in-hospital mortality was evaluated through multivariable logistic regression. Final model selection was conducted using Akaike Information Criterion through bootstrapping. The primary end point was in-hospital mortality, and secondary end points included postoperative morbidities. RESULTS: Out of 2371 patients, 24.9% had mechanical and 75% had bioprosthetic valves implanted during the primary procedure. Propensity matched groups of 324 patients each, were compared. In-hospital mortality for mechanical and bioprosthetic valve explants was 7.1% and 5.9%, respectively (P = 0.632). On multivariable logistic regression analysis, valve type was not a risk factor for mortality [odds ratio (OR) 0.62, 95% confidence interval (CI) 0.37-1.05; P = 0.1]. Age (OR 1.03, 95% CI 1.01-1.05; P < 0.05), left ventricular ejection fraction (OR 1.62, 95% CI 1.08-2.42; P < 0.05), creatinine ≥ 200 mg/dl (OR 2.21, 95% CI 1.17-4.04; P < 0.05) and endocarditis (OR 2.66, 95% CI 1.71-4.14; P < 0.05) emerged as risk factors for mortality. CONCLUSIONS: The type of valve initially implanted (mechanical or bioprosthetic) did not determine mortality. Instead, age, left ventricular ejection fraction, renal impairment and endocarditis were significant risk factors for in-hospital mortality.


Asunto(s)
Bioprótesis , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Prótesis Valvulares Cardíacas/efectos adversos , Reoperación , Endocarditis/cirugía , Reino Unido/epidemiología , Bioprótesis/efectos adversos , Resultado del Tratamiento
10.
J Cardiothorac Surg ; 19(1): 95, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38355617

RESUMEN

BACKGROUND: Rapid-deployment aortic valve replacement (RDAVR) is an alternative to conventional AVR (cAVR) for aortic stenosis. Benefits include a reduction in operative times, facilitation of minimal access surgery and superior haemodynamics compared to conventional valves. However, further evidence is required to inform guidelines, preferably in the form of propensity-matched studies that include mid-term follow-up data. METHODS: This was a single-centre, retrospective, propensity-matched cohort study comparing the Perceval and conventional Perimount Magna Ease valve for short- and mid-term clinical parameters and size-matched mid-term echocardiographic parameters (n = 102 in both groups) from 2014 to 2020. Data were extracted from a nationally managed dataset. RESULTS: There were no demographic differences between the matched groups. The Perceval group had shorter cross-clamp time (Perceval 62 [49-81] minutes; Perimount 79 [63-102] minutes, P < 0.001), shorter bypass time (Perceval 89 [74-114] minutes; Perimount 104 [84-137] minutes, P < 0.001), and more frequent minimally-invasive approaches (Perceval 28%; Perimount 5%, P < 0.001). Size-matched haemodynamics showed initially higher gradients in the Perceval group, but haemodynamics equalised at 12 + months. The Perceval group had a more favourable % change in the left ventricular posterior wall dimension at 2 + years (Perceval - 4.8 ± 18; Perimount 17 ± 2). CONCLUSIONS: The Perceval facilitated shorter operations, which may benefit intermediate-high-risk, elderly patients with comorbidities requiring concomitant procedures. It also facilitated minimally invasive surgery. Size-matched haemodynamic performance was similar at mid-term follow-up, with the Perceval possibly better facilitating regression of left ventricular hypertrophy.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Anciano , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Estudios Retrospectivos , Estudios de Cohortes , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Diseño de Prótesis , Prótesis Valvulares Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología
11.
Am J Cardiol ; 215: 1-7, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38232811

RESUMEN

Structural valve degeneration is increasingly seen given the higher rates of bioprosthetic heart valve use for surgical and transcatheter aortic valve replacement (TAVR). Valve-in-valve TAVR (VIV-TAVR) is an attractive alternate for patients who are otherwise at high risk for reoperative surgery. We compared patients who underwent VIV-TAVR and native valve TAVR through a retrospective analysis of our institutional transcatheter valve therapy (TVT) database from 2013 to 2022. Patients who underwent either a native valve TAVR or VIV-TAVR were included. VIV-TAVR was defined as TAVR in patients who underwent a previous surgical aortic valve replacement. Kaplan-Meier survival analysis was used to obtain survival estimates. A Cox proportional hazards regression model was used for the multivariable analysis of mortality. A total of 3,532 patients underwent TAVR, of whom 198 (5.6%) underwent VIV-TAVR. Patients in the VIV-TAVR cohort were younger than patients who underwent native valve TAVR (79.5 vs 84 years, p <0.001), with comparable number of women and a higher Society of Thoracic Surgeons risk score (6.28 vs 4.46, p <0.001). The VIV-TAVR cohort had a higher incidence of major vascular complications (2.5% vs 0.8%, p = 0.008) but lower incidence of permanent pacemaker placement (2.5% vs 8.1%, p = 0.004). The incidence of stroke was comparable between the groups (VIV-TAVR 2.5% vs native TAVR 2.4%, p = 0.911). The 30-day readmission rates (VIV-TAVR 7.1% vs native TAVR 9%, p = 0.348), as well as in-hospital (VIV-TAVR 2% vs native TAVR 1.4%, p = 0.46), and overall (VIV-TAVR 26.3% vs native TAVR 30.8%, p = 0.18) mortality at a follow-up of 1.8 years (0.83 to 3.5) were comparable between the groups. The survival estimates were also comparable between the groups (log-rank p = 0.27). On multivariable Cox regression analysis, VIV-TAVR was associated with decreased hazards of death (hazard ratio 0.68 [0.5 to 0.9], p = 0.02). In conclusion, VIV-TAVR is a feasible and safe strategy for high-risk patients with bioprosthetic valve failure. There may be potentially higher short-term morbidity with VIV-TAVR, with no overt impact on survival.


Asunto(s)
Bioprótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Falla de Prótesis , Resultado del Tratamiento , Bioprótesis/efectos adversos , Diseño de Prótesis
12.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38244569

RESUMEN

Bioprosthetic valve dysfunction (BVD) is typically a progressive process related to natural wear of the prosthesis. With acute presentations, possible durability issues or iatrogenic causes need to be considered. Here, we present 2 patients with acute BVD of self-expanding, transcatheter aortic valve replacement post-heart catheterization. The presentations and outcomes, in otherwise normally functioning valves antecedent to the heart catheterizations, raise the question of the increased complexity of coronary access in this valve platform, and whether that or other features provide for greater risk of such events. We believe this to be the first publication of such events and they help to highlight the importance of valve implantation planning, as well as familiarity with the potential complexity of coronary access during heart catheterization.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Factores de Riesgo , Diseño de Prótesis , Cateterismo Cardíaco/efectos adversos , Bioprótesis/efectos adversos , Enfermedad Iatrogénica , Estenosis de la Válvula Aórtica/cirugía , Falla de Prótesis
13.
Circ J ; 88(4): 549-558, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-36709983

RESUMEN

BACKGROUND: This study analyzed the safety and performance of the Perceval valve for aortic valve replacement (AVR) in patients at 1 year after undergoing aortic stenosis (AS) treatment, and its effect on significant declines in the platelet count during the immediate postoperative period.Methods and Results: Data were collected retrospectively for the initial 121 patients (median age 77 years; 47.1% females) who underwent Perceval sutureless AVR between May 2019 and July 2022. Implantation was successful in all (100%), with median cross-clamp and CPB times of 59 and 100 min, respectively. Postoperative thrombocytopenia (platelet count <50×103/µL) was noted in 80 (66.1%) patients. Multivariate analysis showed advanced age (>80 years), preoperative low platelet count (<200×103/µL), and a sternotomy approach as significant risk factors for postoperative thrombocytopenia. One (0.8%) patient died within 30 days after the procedure. The 2-year site-reported event rate was 14% (n=17) for all-cause mortality, 0.8% (n=1) for cardiac mortality, 4.1% (n=5) for stroke, and 1.7% (n=2) for endocarditis and valve-related reoperation; there were no instances of paravalvular leakage or structural valve deterioration. CONCLUSIONS: Thrombocytopenia was common after Perceval sutureless AVR, although its impact was not significant. Although Perceval sutureless AVR was found to be a safe and effective option, preoperative assessment of potential bleeding should be performed and the Perceval valve should not be used for patients with a high bleeding risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombocitopenia , Femenino , Humanos , Anciano , Anciano de 80 o más Años , Masculino , Válvula Aórtica/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos , Trombocitopenia/etiología , Diseño de Prótesis , Bioprótesis/efectos adversos
14.
Thorac Cardiovasc Surg ; 72(3): 188-196, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36858066

RESUMEN

BACKGROUND: Bioprosthetic stentless aortic valves may degenerate over time and will require replacement. This study aimed to evaluate early- and mid-term outcomes after isolated surgical redo aortic valve replacement (redo-SAVR) and transcatheter valve-in-valve implantation (TAVI-VIV) for degenerated stentless Freestyle bioprostheses. METHODS: We reviewed records of 56 patients at a single center. Overall, 37 patients (66.1%) received TAVI-VIV and 19 (33.9%) received redo-SAVR. RESULTS: Thirty-day survival was similar in both groups (100%). One-year survival was comparable between groups (97.3% in TAVI-VIV and 100% in redo-SAVR, p = 1.0). The difference in mid-term survival after adjusting for age and EuroScore II was not significant (p = 0.41). The incidence of pacemaker implantation after TAVI-VIV was higher than after redo-SAVR (19.4% vs. 0%, p = 0.08). CONCLUSION: The 30-day and 1-year survival rates after both procedures were outstanding, irrespective of baseline characteristics. Isolated redo-SAVR should be favored in young patients, as the pacemaker implantation rate is lower. TAVI-VIV for degenerated Freestyle prosthesis can be a method of choice in elderly patients and those with high operative risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Falla de Prótesis , Reoperación/métodos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
15.
Can J Cardiol ; 40(2): 300-312, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38072363

RESUMEN

With the expansion of transcatheter aortic valve replacement (TAVR) to younger and lower-surgical-risk patients, many younger and less comorbid patients will be treated with TAVR and are expected to have a life expectancy that will exceed the durability of their transcatheter heart valve. Consequently, the number of patients requiring reintervention will undoubtedly increase in the near future. Redo-TAVR and TAVR explantation followed by surgical aortic valve replacement are the different therapeutic options in the event of bioprosthetic valve failure and the need for reintervention. Patients often anticipate being able to benefit from a redo-TAVR in the event of bioprosthetic valve failure after TAVR, despite the lack of long-term data and the risk of unfavourable anatomy. Our understanding of the feasibility of redo-TAVR is constantly improving thanks to bench test studies and growing worldwide experience. However, much remains unknown. In clinical practice, one of the heart team's objectives is to anticipate the need to reaccess the coronary arteries and implant a second or even a third valve when life expectancy may exceed the durability of the transcatheter heart valve. In this review, we address key definitions in the diagnosis of structural valve deterioration and bioprosthetic valve failure, as well as patient selection and procedural planning for redo-TAVR to reduce periprocedural risk, optimise hemodynamic performance, and maintain coronary access. We describe the bench testing and literature in the redo-TAVR and TAVR explantation fields.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Factores de Riesgo , Bioprótesis/efectos adversos , Diseño de Prótesis
16.
Gen Thorac Cardiovasc Surg ; 72(2): 95-103, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37414971

RESUMEN

BACKGROUND: The ideal conduit for mitral valve replacement (MVR) remains elusive, particularly among younger patients due to increased life expectancy. We perform a pairwise meta-analysis comparing the use of bioprosthetic valves (BPV) and mechanical mitral valves (MMV) in patients < 70 years old undergoing MVR. METHODS: We comprehensively searched medical databases to identify studies comparing the use of BPV and MMV in patients < 70 years old undergoing MVR. Pairwise meta-analysis was performed using the Mantel-Haenszel method in R version 4.0.2. Outcomes were pooled using the random effect model as risk ratios (RR) with their 95% confidence intervals (95% CI). RESULTS: 16,879 patients from 15 studies were pooled. Compared to MMV, BPV was associated with significantly higher rates of 30-day mortality (RR 1.53, p = 0.0006) but no difference in 30-day stroke (RR 0.70, p = 0.43). At a weighted mean follow-up duration of 14.1 years, BPV was associated with higher rates of long-term mortality (RR 1.28, p = 0.0054). No difference was seen between the two groups for risk of long-term stroke (RR 0.92, p = 0.67), reoperation(RR 1.72, p = 0.12), or major-bleeding (RR 0.57, p = 0.10) at a weighted mean follow-up duration of 11.7, 11.3, and 11.9 years, respectively. CONCLUSION: The use of MMV in patients < 70 undergoing MVR is associated with lower rates of 30-day/long-term mortality compared to BPV. No significant differences were observed for risk of 30-day/long-term stroke, long-term reoperation, and long-term major bleeding. These findings support the use of MMV in younger patients, although prospective, randomized trials are still needed.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Humanos , Anciano , Válvula Mitral/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Accidente Cerebrovascular/etiología , Hemorragia/etiología , Reoperación , Bioprótesis/efectos adversos , Resultado del Tratamiento , Válvula Aórtica/cirugía
17.
Eur J Cardiothorac Surg ; 65(1)2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-37756697

RESUMEN

OBJECTIVES: This population-based cohort study investigated mid-term outcome after surgical aortic valve replacement with a bioprosthetic or mechanical valve prosthesis in patients aged <50 years in a European social welfare state. METHODS: We analysed patient data from the main social insurance carriers in Austria (2010-2020). Subsequent patient-level record linkage with national health data provided patient characteristics and clinical outcome. Survival, reoperation, myocardial infarction, heart failure, embolic stroke or intracerebral haemorrhage, bleeding other than intracerebral haemorrhage and major adverse cardiac events were evaluated as outcomes. RESULTS: A total of 991 patients were analysed. Regarding demographics, no major differences between groups were observed. Multivariable Cox regression revealed no significant difference in overall survival (P = 0.352) with a median follow-up time of 6.2 years. Reoperation-free survival was decreased (hazard ratio = 1.560 [95% CI: 1.076-2.262], P = 0.019) and the risk for reoperation was increased (hazard ratio = 2.770 [95% CI: 1.402-5.472], P = 0.003) in patients who received bioprostheses. Estimated probability of death after reoperation was 0.23 (CL: 0.08-0.35) after 2 years and 0.34 (CL: 0.06-0.53) after 10 years over both groups. Regarding further outcomes, no significant differences between the two groups were observed. CONCLUSIONS: In patients below 50 years of age receiving aortic valve replacement, implantation of bioprostheses when compared to mechanical heart valve prostheses was associated with a significantly higher rate of reoperations and reduced reoperation-free survival. Nevertheless, we could not observe a difference in overall survival. However, long-term follow-up has to evaluate that a significantly lower rate of reoperations may translate in consistently improved long-term survival.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Persona de Mediana Edad , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios de Cohortes , Diseño de Prótesis , Reoperación , Bioprótesis/efectos adversos , Hemorragia Cerebral/etiología , Puntaje de Propensión , Resultado del Tratamiento , Estudios Retrospectivos , Falla de Prótesis
19.
Heart ; 110(4): 299-305, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-37643771

RESUMEN

OBJECTIVES: Lipoprotein(a) (Lp(a)) is associated with an increased incidence of native aortic stenosis, which shares similar pathological mechanisms with bioprosthetic aortic valve (bAV) degeneration. However, evidence regarding the role of Lp(a) concentrations in bAV degeneration is lacking. This study aims to evaluate the association between Lp(a) concentrations and bAV degeneration. METHODS: In this retrospective multicentre study, patients who underwent a bAV replacement between 1 January 2010 and 31 December 2020 and had a Lp(a) measurement were included. Echocardiography follow-up was performed to determine the presence of bioprosthetic valve degeneration, which was defined as an increase >10 mm Hg in mean gradient from baseline with concomitant decrease in effective orifice area and Doppler Velocity Index, or new moderate/severe prosthetic regurgitation. Levels of Lp(a) were compared between patients with and without degeneration and Cox regression analysis was performed to investigate the association between Lp(a) levels and bioprosthetic valve degeneration. RESULTS: In total, 210 cases were included (mean age 74.1±9.4 years, 72.4% males). Median time between baseline and follow-up echocardiography was 4.4 (IQR 3.7) years. Bioprostheses degeneration was observed in 33 (15.7%) patients at follow-up. Median serum levels of Lp(a) were significantly higher in patients affected by degeneration versus non-affected cases: 50.0 (IQR 72.0) vs 15.6 (IQR 48.6) mg/dL, p=0.002. In the regression analysis, high Lp(a) levels (≥30 mg/dL) were associated with degeneration both in a univariable analysis (HR 3.6, 95% CI 1.7 to 7.6, p=0.001) and multivariable analysis adjusted by other risk factors for bioprostheses degeneration (HR 4.4, 95% CI 1.9 to 10.4, p=0.001). CONCLUSIONS: High serum Lp(a) is associated with bAV degeneration. Prospective studies are needed to confirm these findings and to investigate whether lowering Lp(a) levels could slow bioprostheses degradation.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Lipoproteína(a) , Estenosis de la Válvula Aórtica/complicaciones , Ecocardiografía , Insuficiencia de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Bioprótesis/efectos adversos , Resultado del Tratamiento