Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.935
Filtrar
1.
World J Urol ; 42(1): 322, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747982

RESUMEN

PURPOSE: Utility of prostate-specific antigen density (PSAd) for risk-stratification to avoid unnecessary biopsy remains unclear due to the lack of standardization of prostate volume estimation. We evaluated the impact of ellipsoidal formula using multiparametric magnetic resonance (MRI) and semi-automated segmentation using tridimensional ultrasound (3D-US) on prostate volume and PSAd estimations as well as the distribution of patients in a risk-adapted table of clinically significant prostate cancer (csPCa). METHODS: In a prospectively maintained database of 4841 patients who underwent MRI-targeted and systematic biopsies, 971 met inclusions criteria. Correlation of volume estimation was assessed by Kendall's correlation coefficient and graphically represented by scatter and Bland-Altman plots. Distribution of csPCa was presented using the Schoots risk-adapted table based on PSAd and PI-RADS score. The model was evaluated using discrimination, calibration plots and decision curve analysis (DCA). RESULTS: Median prostate volume estimation using 3D-US was higher compared to MRI (49cc[IQR 37-68] vs 47cc[IQR 35-66], p < 0.001). Significant correlation between imaging modalities was observed (τ = 0.73[CI 0.7-0.75], p < 0.001). Bland-Altman plot emphasizes the differences in prostate volume estimation. Using the Schoots risk-adapted table, a high risk of csPCa was observed in PI-RADS 2 combined with high PSAd, and in all PI-RADS 4-5. The risk of csPCa was proportional to the PSAd for PI-RADS 3 patients. Good accuracy (AUC of 0.69 and 0.68 using 3D-US and MRI, respectively), adequate calibration and a higher net benefit when using 3D-US for probability thresholds above 25% on DCA. CONCLUSIONS: Prostate volume estimation with semi-automated segmentation using 3D-US should be preferred to the ellipsoidal formula (MRI) when evaluating PSAd and the risk of csPCa.


Asunto(s)
Antígeno Prostático Específico , Próstata , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Antígeno Prostático Específico/sangre , Anciano , Persona de Mediana Edad , Tamaño de los Órganos , Próstata/patología , Próstata/diagnóstico por imagen , Medición de Riesgo , Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética/métodos , Toma de Decisiones Clínicas , Imágenes de Resonancia Magnética Multiparamétrica , Estudios Prospectivos
2.
J Infect Dev Ctries ; 18(4): 595-599, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38728642

RESUMEN

INTRODUCTION: This study aims to show the bacteriologic picture of acute prostatitis and bacteremia caused by infective agent after transrectal ultrasound-guided prostate biopsy (TRUSBx) and to determine the resistance rates of the infections in patients undergoing transrectal biopsy and to guide prophylaxis approach before biopsy. METHODOLOGY: The retrospective data of 935 patients who underwent TRUSBx between January 2010 to January 2019 were reviewed. Pre-biopsy urine cultures and antimicrobial susceptibility were obtained. Subsequently, patients admitted to the hospital with any complaint after biopsy were examined for severe infection complications. RESULTS: Of the 430 (61.7%) patients who underwent urine culture before the procedure, 45 (10.5%) had growth; 30 (66.7%) of the growing microorganisms were Escherichia coli. Twenty (44.4%) of all Gram-negative agents in pre-biopsy urine culture were susceptible to quinolone. Post TRUSBx bacteremia was present in 18.2%, urinary system infection in 83.6%, and hospitalization in 61.8% of 55 patients who were admitted to the hospital. In the isolated gram-negative microorganisms, fluoroquinolones resistance in urinary system infections was seen in 40% and bacteremia was seen in 70% of the cases. ESBL-producing Gram-negative bacteria were determined in 40% of infections in blood and 38.5% of urinary system infections in the post biopsy period in the current study. CONCLUSIONS: These high antibiotic resistance rates suggest that we better review our pre-procedure prophylaxis approaches.


Asunto(s)
Antibacterianos , Profilaxis Antibiótica , Bacteriemia , Próstata , Humanos , Masculino , Estudios Retrospectivos , Profilaxis Antibiótica/métodos , Persona de Mediana Edad , Anciano , Próstata/patología , Próstata/microbiología , Antibacterianos/uso terapéutico , Antibacterianos/farmacología , Bacteriemia/prevención & control , Bacteriemia/microbiología , Farmacorresistencia Bacteriana , Prostatitis/microbiología , Prostatitis/prevención & control , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Infecciones Urinarias/prevención & control , Infecciones Urinarias/microbiología
3.
Radiology ; 311(2): e230750, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38713024

RESUMEN

Background Multiparametric MRI (mpMRI) improves prostate cancer (PCa) detection compared with systematic biopsy, but its interpretation is prone to interreader variation, which results in performance inconsistency. Artificial intelligence (AI) models can assist in mpMRI interpretation, but large training data sets and extensive model testing are required. Purpose To evaluate a biparametric MRI AI algorithm for intraprostatic lesion detection and segmentation and to compare its performance with radiologist readings and biopsy results. Materials and Methods This secondary analysis of a prospective registry included consecutive patients with suspected or known PCa who underwent mpMRI, US-guided systematic biopsy, or combined systematic and MRI/US fusion-guided biopsy between April 2019 and September 2022. All lesions were prospectively evaluated using Prostate Imaging Reporting and Data System version 2.1. The lesion- and participant-level performance of a previously developed cascaded deep learning algorithm was compared with histopathologic outcomes and radiologist readings using sensitivity, positive predictive value (PPV), and Dice similarity coefficient (DSC). Results A total of 658 male participants (median age, 67 years [IQR, 61-71 years]) with 1029 MRI-visible lesions were included. At histopathologic analysis, 45% (294 of 658) of participants had lesions of International Society of Urological Pathology (ISUP) grade group (GG) 2 or higher. The algorithm identified 96% (282 of 294; 95% CI: 94%, 98%) of all participants with clinically significant PCa, whereas the radiologist identified 98% (287 of 294; 95% CI: 96%, 99%; P = .23). The algorithm identified 84% (103 of 122), 96% (152 of 159), 96% (47 of 49), 95% (38 of 40), and 98% (45 of 46) of participants with ISUP GG 1, 2, 3, 4, and 5 lesions, respectively. In the lesion-level analysis using radiologist ground truth, the detection sensitivity was 55% (569 of 1029; 95% CI: 52%, 58%), and the PPV was 57% (535 of 934; 95% CI: 54%, 61%). The mean number of false-positive lesions per participant was 0.61 (range, 0-3). The lesion segmentation DSC was 0.29. Conclusion The AI algorithm detected cancer-suspicious lesions on biparametric MRI scans with a performance comparable to that of an experienced radiologist. Moreover, the algorithm reliably predicted clinically significant lesions at histopathologic examination. ClinicalTrials.gov Identifier: NCT03354416 © RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Aprendizaje Profundo , Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Masculino , Humanos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Estudios Prospectivos , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Persona de Mediana Edad , Algoritmos , Próstata/diagnóstico por imagen , Próstata/patología , Biopsia Guiada por Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos
4.
Int J Comput Assist Radiol Surg ; 19(5): 841-849, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38704793

RESUMEN

PURPOSE: Deep learning-based analysis of micro-ultrasound images to detect cancerous lesions is a promising tool for improving prostate cancer (PCa) diagnosis. An ideal model should confidently identify cancer while responding with appropriate uncertainty when presented with out-of-distribution inputs that arise during deployment due to imaging artifacts and the biological heterogeneity of patients and prostatic tissue. METHODS: Using micro-ultrasound data from 693 patients across 5 clinical centers who underwent micro-ultrasound guided prostate biopsy, we train and evaluate convolutional neural network models for PCa detection. To improve robustness to out-of-distribution inputs, we employ and comprehensively benchmark several state-of-the-art uncertainty estimation methods. RESULTS: PCa detection models achieve performance scores up to 76 % average AUROC with a 10-fold cross validation setup. Models with uncertainty estimation obtain expected calibration error scores as low as 2 % , indicating that confident predictions are very likely to be correct. Visualizations of the model output demonstrate that the model correctly identifies healthy versus malignant tissue. CONCLUSION: Deep learning models have been developed to confidently detect PCa lesions from micro-ultrasound. The performance of these models, determined from a large and diverse dataset, is competitive with visual analysis of magnetic resonance imaging, the clinical benchmark to identify PCa lesions for targeted biopsy. Deep learning with micro-ultrasound should be further studied as an avenue for targeted prostate biopsy.


Asunto(s)
Aprendizaje Profundo , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/diagnóstico , Biopsia Guiada por Imagen/métodos , Ultrasonografía/métodos , Redes Neurales de la Computación , Ultrasonografía Intervencional/métodos
5.
Radiol Cardiothorac Imaging ; 6(3): e230234, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38695742

RESUMEN

Purpose To compare the tissue adequacy and diagnostic accuracy of US-guided biopsies of peripheral pulmonary lesions (PPLs) with and without contrast agents. Materials and Methods A retrospective study was conducted at four medical centers in patients with PPLs who underwent US-guided percutaneous transthoracic needle biopsy (PTNB) between January 2017 and October 2022. The patients were divided into contrast-enhanced US (CEUS) and US groups based on whether prebiopsy CEUS evaluation was performed. Tissue adequacy and the diagnostic accuracy of PTNB, stratified by lesion size, were analyzed and compared between groups. A propensity score matching (PSM) analysis was conducted using the nearest-neighbor matching method. Results A total of 1027 lesions were analyzed, with 634 patients (mean age, 59.4 years ± 13.0 [SD]; 413 male) in the US group and 393 patients (mean age, 61.2 years ± 12.5; 270 male) in the CEUS group. The CEUS group produced more acceptable samples than the US group (98.2% vs 95.7%; P = .03) and achieved higher diagnostic accuracy (96.9% vs 94.2%; P = .04), with no evidence of a difference in sensitivity (96.7% vs 94.0%; P = .06). PSM and stratified analyses (n = 358 per group) indicated higher tissue adequacy (99.0% vs 95.7%; P = .04) and diagnostic accuracy (98.5% vs 92.9%; P = .006) in the CEUS group compared with the US group for 2-7-cm PPLs but not for lesions larger than 7 cm. Conclusion PTNB with prebiopsy CEUS evaluation demonstrated significantly better tissue adequacy and diagnostic accuracy compared with US guidance alone for PPLs ranging from 2 to 7 cm, with similar biopsy performance achieved between groups for lesions larger than 7 cm. Keywords: Contrast Material, Thoracic Diseases, Ultrasonography, Image-Guided Biopsy © RSNA, 2024.


Asunto(s)
Medios de Contraste , Biopsia Guiada por Imagen , Ultrasonografía Intervencional , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Biopsia Guiada por Imagen/métodos , Ultrasonografía Intervencional/métodos , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/diagnóstico por imagen , Pulmón/patología , Pulmón/diagnóstico por imagen , Anciano
6.
World J Urol ; 42(1): 285, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38695883

RESUMEN

PURPOSE: This study is to investigate the diagnostic value of 68Ga-PSMA-11 in improving the concordance between mpMRI-TB and combined biopsy (CB) in detecting PCa. METHODS: 115 consecutive men with 68Ga-PSMA-11 PET/CT prior to prostate biopsy were included for analysis. PSMA intensity, quantified as maximum standard uptake value (SUVmax), minimum apparent diffusion coefficient (ADCmin) and other clinical characteristics were evaluated relative to biopsy concordance using univariate and multivariate logistic regression analyses. A prediction model was developed based on the identified parameters, and a dynamic online diagnostic nomogram was constructed, with its discrimination evaluated through the area under the ROC curve (AUC) and consistency assessed using calibration plots. To assess its clinical applicability, a decision curve analysis (DCA) was performed, while internal validation was conducted using bootstrapping methods. RESULTS: Concordance between mpMRI-TB and CB occurred in 76.5% (88/115) of the patients. Multivariate logistic regression analyses performed that SUVmax (OR= 0.952; 95% CI 0.917-0.988; P= 0.010) and ADCmin (OR= 1.006; 95% CI 1.003-1.010; P= 0.001) were independent risk factors for biopsy concordance. The developed model showed a sensitivity, specificity, accuracy and AUC of 0.67, 0.78, 0.81 and 0.78 in the full sample. The calibration curve demonstrated that the nomogram's predicted outcomes closely resembled the ideal curve, indicating consistency between predicted and actual outcomes. Furthermore, the decision curve analysis (DCA) highlighted the clinical net benefit achievable across various risk thresholds. These findings were reinforced by internal validation. CONCLUSIONS: The developed prediction model based on SUVmax and ADCmin showed practical value in guiding the optimization of prostate biopsy pattern. Lower SUVmax and Higher ADCmin values are associated with greater confidence in implementing mono-TB and safely avoiding SB, effectively balancing benefits and risks.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Anciano , Humanos , Masculino , Biopsia/métodos , Isótopos de Galio , Radioisótopos de Galio , Biopsia Guiada por Imagen/métodos , Nomogramas , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Valor Predictivo de las Pruebas , Próstata/patología , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Estudios Retrospectivos , Medición de Riesgo
7.
Ther Adv Respir Dis ; 18: 17534666241249150, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38757612

RESUMEN

BACKGROUND: Although electromagnetic navigation bronchoscopy (ENB) is highly sensitive in the diagnosis of peripheral pulmonary nodules (PPNs), its diagnostic yield for subgroups of smaller PPNs is under evaluation. OBJECTIVES: Diagnostic yield evaluation of biopsy using ENB for PPNs <2 cm. DESIGN: The diagnostic yield, sensitivity, specificity, positive predictive value, and negative predictive value of the ENB-mediated biopsy for PPNs were evaluated. METHODS: Patients who had PPNs with diameters <2 cm and underwent ENB-mediated biopsy between May 2015 and February 2020 were consecutively enrolled. The final diagnosis was made via pathological examination after surgery. RESULTS: A total of 82 lesions from 65 patients were analyzed. The median tumor size was 11 mm. All lesions were subjected to ENB-mediated biopsy, of which 29 and 53 were classified as malignant and benign, respectively. Subsequent segmentectomy, lobectomy, or wedge resection, following pathological examinations were performed on 64 nodules from 57 patients. The overall sensitivity, specificity, positive predictive value, and negative predictive value for nodules <2 cm were 53.3%, 91.7%, 92.3%, and 51.2%, respectively. The receiver operating curve showed an area under the curve of 0.721 (p < 0.001). Additionally, the sensitivity, specificity, positive predictive value, and negative predictive value were 62.5%, 100%, 100%, and 42.9%, respectively, for nodules with diameters equal to or larger than 1 cm; and 30.8%, 86.7%, 66.7%, and 59.1%, respectively, for nodules less than 1 cm. In the subgroup analysis, neither the lobar location nor the distance of the PPNs to the pleura affected the accuracy of the ENB diagnosis. However, the spiculated sign had a negative impact on the accuracy of the ENB biopsy (p = 0.010). CONCLUSION: ENB has good specificity and positive predictive value for diagnosing PPNs <2 cm; however, the spiculated sign may negatively affect ENB diagnostic accuracy. In addition, the diagnostic reliability may only be limited to PPNs equal to or larger than 1 cm.


Asunto(s)
Broncoscopía , Fenómenos Electromagnéticos , Neoplasias Pulmonares , Nódulos Pulmonares Múltiples , Valor Predictivo de las Pruebas , Humanos , Broncoscopía/métodos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/diagnóstico , Nódulos Pulmonares Múltiples/patología , Nódulos Pulmonares Múltiples/diagnóstico , Nódulos Pulmonares Múltiples/cirugía , Estudios Retrospectivos , Carga Tumoral , Adulto , Nódulo Pulmonar Solitario/patología , Nódulo Pulmonar Solitario/diagnóstico , Nódulo Pulmonar Solitario/cirugía , Nódulo Pulmonar Solitario/diagnóstico por imagen , Reproducibilidad de los Resultados , Anciano de 80 o más Años , Biopsia Guiada por Imagen/métodos
8.
World J Urol ; 42(1): 332, 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38758413

RESUMEN

BACKGROUND: Transperineal Prostate Biopsy (TPB) is a commonly used technique for the diagnosis of prostate cancer due to growing concerns related to infectious complications associated with transrectal ultrasound-guided prostate biopsy (TRUSB). TPB is associated with an infective complication rate of near zero, however, acute urinary retention (AUR) remains the leading complication causing morbidity. Previously in TRUSB, there was weak evidence that alpha-blockers reduce AUR rates, and their usage has been extrapolated to clinical practice with TPB. This review aims to explore if there is an evidence base for using alpha-blockers to prevent AUR following TPB. METHODS: A systematic approach was used to search Ovid Medline and Embase using keywords related to "Transperineal" and "Retention". Articles were then screened by applying inclusion and exclusion criteria to find studies that compared alpha-blocker recipients to no alpha-blocker use in the perioperative period and the subsequent effect on AUR in TPB. RESULTS: 361 records were identified in the initial search to produce 5 studies included in the final review. No randomised controlled trials (RCTs) were identified. One observational study showed a reduction in AUR rate from 12.5% to 5.3% with a single dose of tamsulosin. A previous systematic review of complications associated with prostate biopsy concluded there may be a potential benefit to alpha-blockers given in the TPB perioperative period. Three observational studies demonstrated a harmful effect related to alpha-blocker use; however, this was well explained by their clear limitations. CONCLUSION: Based on this review and the extrapolation from TRUSB data, perioperative alpha-blockers may offer some weak benefits in preventing AUR following TPB. However, there is significant scope and need for an RCT to further develop the evidence base further given the significant gap in the literature and lack of a standard alpha blocker protocol in TPB.


Asunto(s)
Perineo , Próstata , Retención Urinaria , Humanos , Masculino , Retención Urinaria/etiología , Retención Urinaria/prevención & control , Próstata/patología , Neoplasias de la Próstata/patología , Antagonistas Adrenérgicos alfa/uso terapéutico , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Biopsia Guiada por Imagen/métodos , Biopsia Guiada por Imagen/efectos adversos
10.
World J Urol ; 42(1): 279, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693444

RESUMEN

PURPOSE: Transrectal ultrasound-guided prostate biopsy (TRUS-Bx) is associated with a 1-8% risk of post-biopsy sepsis (PBS). A recent study described an isopropyl alcohol needle washing protocol that significantly decreased PBS rates. The current study examined the efficacy of this technique in our clinic population. MATERIALS AND METHODS: Data were reviewed for 1250 consecutive patients undergoing TRUS-Bx at the Charlie Norwood VA Medical Center from January 2017 to January 2023. Needle washing was adopted in February 2021. Complications occurring within 30 days after TRUS-Bx were recorded. RESULTS: There were 912 patients in group 1 (without needle washing) and 338 in group 2 (with needle washing). Groups had equivalent demographic features, and men of African descent comprised 70% of patients. Standard 12 core biopsies were done in 83% and 82% in groups 1 and 2, respectively (p = 0.788). Total complication rates were 4% and 2% in groups 1 and 2, respectively (p = 0.077). There were 13 sepsis events in group 1 (1.4%) and none in group 2 (p = 0.027). Clavien-Dindo Grade I-III complications occurred in 25 (2.7%) and 7 (2.1%) patients in groups 1 and 2, respectively (p = 0.505). Standard antibiotic prophylaxis (PO fluoroquinolone and IM gentamicin) was given in 80% and 86% of patients in groups 1 and 2, respectively (p = 0.030). Subset analysis limited to patients who received standard prophylaxis showed a significant difference in sepsis rates (1.5% vs 0%; p = 0.036). CONCLUSIONS: Adoption of isopropyl alcohol needle washing was associated with a significant decrease in PBS events.


Asunto(s)
2-Propanol , Biopsia Guiada por Imagen , Próstata , Sepsis , Humanos , Masculino , Sepsis/prevención & control , Anciano , Próstata/patología , Persona de Mediana Edad , 2-Propanol/administración & dosificación , Estudios Retrospectivos , Biopsia Guiada por Imagen/métodos , Neoplasias de la Próstata/patología , Ultrasonografía Intervencional , Agujas , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/epidemiología
11.
World J Urol ; 42(1): 297, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709326

RESUMEN

PURPOSE: The goal of this study is to address if detection rates of clinically significant prostate cancer (csPCa) can be increased by additional perilesional biopsies (PB) in magnetic resonance (MR)/ultrasound fusion prostate biopsy in biopsy-naïve men. METHODS: This prospective, non-randomized, surgeon-blinded study was conducted between February 2020 and July 2022. Patients were included with PSA levels < 20 ng/ml and ≥ one PI-RADS lesion (grades 3-5) per prostate lobe. Prostate biopsy was performed by two urologists. The first performed the MR-fusion biopsy with 3-5 targeted biopsies (TB) and 6 PB in a standardized pattern. The second performed the systematic (12-fold) biopsy (SB) without knowledge of the MR images. Primary outcome of this study is absence or presence of csPCa (≥ ISUP grade 2) comparing TB, PB and SB, using McNemar test. RESULTS: Analyses were performed for each PI-RADS lesion (n = 218). There was a statistically significant difference in csPC detection rate of TB + SB between PI-RADS 3, 4 and 5 lesions (18.0% vs. 42.5% vs. 82.6%, p < 0.001) and TB + PB (19.7% vs. 29.1% vs. 78.3%). Comparing only maximum ISUP grade per lesion, even SB plus TB plus PB did not detect more csPCa compared to SB plus TB (41.3% vs. 39.9%, p > 0.05). CONCLUSION: We present prospective study data investigating the role of perilesional biopsy in detection of prostate cancer. We detected no statistically significant difference in the detection of csPCa by the addition of PB. Therefore, we recommend continuing 12-fold bilateral SB in addition to TB.


Asunto(s)
Biopsia Guiada por Imagen , Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Estudios Prospectivos , Biopsia Guiada por Imagen/métodos , Anciano , Persona de Mediana Edad , Próstata/patología , Próstata/diagnóstico por imagen , Método Simple Ciego
13.
Folia Med (Plovdiv) ; 66(2): 179-187, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38690812

RESUMEN

INTRODUCTION: Evaluation of patients with peripheral lung lesions and lesions of the chest wall and mediastinum is challenging. The nature of the lesion identified by imaging studies can be determined by histological evaluation of biopsies. An important place in this direction is the ever-increasing popularity among thoracic surgeons of the transthoracic biopsy with a cutting needle under ultrasound control (US-TTCNB).


Asunto(s)
Mediastino , Pared Torácica , Humanos , Pared Torácica/diagnóstico por imagen , Pared Torácica/patología , Mediastino/patología , Mediastino/diagnóstico por imagen , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/diagnóstico por imagen , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Enfermedades Pulmonares/patología , Enfermedades Pulmonares/diagnóstico por imagen , Enfermedades Pulmonares/etiología , Pulmón/patología , Pulmón/diagnóstico por imagen , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos
14.
Zhonghua Yi Xue Za Zhi ; 104(16): 1403-1409, 2024 Apr 23.
Artículo en Chino | MEDLINE | ID: mdl-38644291

RESUMEN

Objective: To investigate the safety and accuracy of CT-guided intracranial puncture biopsy and the possible influencing factors of postoperative bleeding complications. Methods: A case series study. A retrospective analysis was conducted on 101 patients who underwent CT-guided intracranial puncture biopsy at the First Affiliated Hospital of Zhengzhou University from January 2017 to December 2021. The basic data of patients and the safety and accuracy of CT-guided intracranial puncture biopsy were analyzed statistically. Univariate and multivariate logistic regression analysis were used to screen the influencing factors of bleeding complications in CT-guided intracranial puncture biopsy, and the bleeding complications in glioma subgroup were analyzed. Results: Among the 101 patients, 53 were males and 48 were females, aged (53.7±17.2) years. The average diameter of intracranial lesions was (3.5±1.4) cm, while the vertical distance from the lesion to the meninges was (2.4±1.7) cm. The needle's intracranial depth reached (3.2±1.8) cm, with adjustments averaging (3±1) occurrences and an average procedural duration of (40.2±12.9) minutes. Pathological diagnoses included glioma (36 cases), gliosis (3 cases), lymphoma (32 cases), metastatic tumors (7 cases), inflammatory lesions (13 cases), and 10 indeterminate cases. The positive rate of puncture pathology was 90.1% (91/101), and the diagnostic coincidence rate was 94.0% (78/83). The incidence of bleeding complications in CT-guided intracranial puncture biopsy was 26.7% (27/101), of which 23 cases had small intratoma or needle path bleeding, 4 cases had massive bleeding, and 2 cases died. The patients were divided into bleeding group (n=27) and no bleeding group (n=74), according to the presence or absence of bleeding. The results of univariate logistic regression analysis showed that thrombin time≥15 s and the number of needle adjustment were the factors affecting the occurrence of bleeding complications (both P<0.05), and the results of multivariate logistic regression showed that thrombin time≥15 s was the related factor for bleeding. Patients with thrombin time≥15 s had a 3.045 times higher risk of bleeding than those with thrombin time<15 s (OR=3.045,95%CI:1.189-7.799,P=0.020). Among the 101 patients, 36 cases of midbrain glioma were divided into low-grade glioma group (n=11) and high-grade glioma group (n=25) according to the pathological grade. Subgroup analysis showed that the risk of bleeding for high-grade gliomas was 9.231 times higher than that for low-grade gliomas (OR=9.231,95%CI:1.023-83.331,P=0.031). Conclusions: CT-guided intracranial puncture biopsy is safe and feasible with high accuracy. Complication rates are associated with thrombin time≥15 s, especially high-grade glioma, which increases the risk of postoperative bleeding.


Asunto(s)
Neoplasias Encefálicas , Biopsia Guiada por Imagen , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Glioma/patología , Adulto , Anciano , Encéfalo/patología , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos
15.
Am J Otolaryngol ; 45(1): 104091, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38652678

RESUMEN

BACKGROUND: Thyroid nodules are common in the general population. Ultrasonography is the most efficient diagnostic approach to evaluate thyroid nodules. The US FNAC procedure can be performed using either the short axis (perpendicular), or a long axis (parallel) approach to visualize the needle as it is advanced toward the desired nodule. The main aim of this study was to compare the percentage of non-diagnostic results between the long and short axis approach. METHODS: A prospective study that included a randomized controlled trial and was divided into two arms-the short axis and the long axis-was conducted. A total of 245 thyroid nodules were collected through the fine needle aspiration cytology, performed with ultrasound, from march 2021 to march 2022. The patient's demographic information were collected and also nodules characteristics. RESULTS: Of 245 nodules sampled, 122 were sampled with the long axis method, while 123 with the short axis method. There is not significantly less non diagnostic approach with either method compared to the other (11.5 % vs 16.3 % respectively). DISCUSSION: Previous studies came to the conclusion that the long axis method yields fewer non diagnostic samples. This study evaluated the two FNA approaches which were proceeded by the same physician who is expert in both techniques. CONCLUSION: The US FNAC performed in the long axis approach will not produce more conclusive results and less non diagnostic results (Bethesda category 1) than the short axis approach one.


Asunto(s)
Nódulo Tiroideo , Humanos , Nódulo Tiroideo/patología , Nódulo Tiroideo/diagnóstico por imagen , Estudios Prospectivos , Femenino , Masculino , Persona de Mediana Edad , Biopsia con Aguja Fina/métodos , Adulto , Glándula Tiroides/patología , Glándula Tiroides/diagnóstico por imagen , Anciano , Biopsia Guiada por Imagen/métodos , Ultrasonografía Intervencional/métodos , Ultrasonografía/métodos
16.
Acta Cytol ; 68(2): 121-127, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38599193

RESUMEN

INTRODUCTION: Approximately 15% of fine-needle aspiration (FNA) of thyroid nodules are considered nondiagnostic. Several factors are potentially involved, including clinical and nodule features but also the gauge (G) of the needle used. However, few studies have compared the cytological adequacy obtained with different gauge needles and the data are controversial. We aimed to evaluate cytological adequacy results using 23- or 25-G needles. METHODS: This study is an observational and prospective study of thyroid nodules submitted to ultrasound-guided FNA. The procedure was performed randomly using 23- or 25-G needles. The samples were reported by different cytopathologists who were blinded to the information of the gauge of the needle used. Statistical analysis was performed to compare cytological adequacy of FNA between the two groups. RESULTS: A total of 177 thyroid nodules were included - 98 (55.4%) using 23-G and 79 (44.6%) using 25-G needles. The 23-G group presented a higher rate of cytological adequacy (69.4% [68/98] vs. 46.8% [37/79], p = 0.002). No differences were found between the two groups regarding patient or nodule characteristics. On logistic regression, 23-G needles correlated with better cytological adequacy (unadjusted OR 2.57 [95% CI: 1.39-4.77]), even after adjusting for nodule dimension, location, and type of cytology (slides +/- additional liquid-based cytology) (adjusted OR 2.44 [95% CI: 1.23-4.84]). CONCLUSION: The gauge of the needle used was found to be an independent predictor of cytological adequacy, with 23-G needles providing more adequate samples. Further investigation is needed to confirm our results in order to stablish the optimal diagnosis technique.


Asunto(s)
Nódulo Tiroideo , Humanos , Nódulo Tiroideo/patología , Nódulo Tiroideo/diagnóstico , Estudios Prospectivos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Biopsia con Aguja Fina/métodos , Anciano , Agujas , Ultrasonografía Intervencional/métodos , Reproducibilidad de los Resultados , Valor Predictivo de las Pruebas , Diseño de Equipo , Biopsia Guiada por Imagen/métodos , Glándula Tiroides/patología
17.
Abdom Radiol (NY) ; 49(5): 1638-1645, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38658444

RESUMEN

PURPOSE: Ultrasound-guided percutaneous biopsy (USPB) of the native kidneys is the preferred diagnostic method for several nephrological conditions in both adult and pediatric populations. Conventionally, native kidney biopsies are conducted with patients in the prone position (PP). However, an alternative approach involving the supine oblique antero-lateral position (SALP) has been explored, particularly for individuals who are obese, elderly, or critically ill. METHODS: This study aimed to assess the feasibility and outcomes of USPB performed in SALP with a Free-Flank setting (FF-SALP) in pediatric patients (Group A) compared to adults (Group B). Data from kidney biopsies conducted between 2008 and 2021 were gathered. The study focused on the safety and the prevalence of biopsy samples containing a minimum of 10 glomeruli, histopathological yield in both groups. RESULTS: Complication rates were low in both groups (5.6% vs. 3.7%; p = 0.454), without major complications noted. The pediatric group achieved a significantly higher mean number of glomeruli per biopsy compared to the adult group (20.6 ± 12.3 vs. 15.7 ± 9.4; p < 0.001). However, when evaluating the minimum threshold of 10 glomeruli (76.3% vs. 68.5%; p = 0.072) and histopathologic yield (95.3% vs. 93.5%; p = 0.408), no differences were observed between groups. CONCLUSION: USPB of native kidneys in the FF-SALP position is a safe and effective method for tissue sampling in patients with parenchymal disease. It demonstrated comparable diagnostic yields and complication rates in the pediatric and adult populations, providing advantages in terms of airway management, making it particularly useful for pediatric patients that require general anesthesia.


Asunto(s)
Biopsia Guiada por Imagen , Riñón , Posicionamiento del Paciente , Ultrasonografía Intervencional , Humanos , Niño , Masculino , Femenino , Ultrasonografía Intervencional/métodos , Adulto , Biopsia Guiada por Imagen/métodos , Posicionamiento del Paciente/métodos , Riñón/patología , Riñón/diagnóstico por imagen , Adolescente , Posición Supina , Enfermedades Renales/diagnóstico por imagen , Enfermedades Renales/patología , Persona de Mediana Edad , Anciano , Preescolar , Estudios Retrospectivos , Estudios de Factibilidad
18.
Technol Cancer Res Treat ; 23: 15330338241246636, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38629205

RESUMEN

OBJECTIVE: This study intends to examine the anticipatory power of clinical and radiological parameters in detecting clinically significant prostate cancer in patients demonstrating Prostate Imaging Reporting and Data System 3 lesions. METHODS: This was a retrospective study. The study included participation from 453 patients at the First Affiliated Hospital of Soochow University, sampled between September 2017 through August 2022. Each patient underwent a routine 12-core prostate biopsy followed by a 2 to 5 core fusion-targeted biopsy. We utilized both univariate and multivariate logistic regression analyses to identify the parameters that have a correlation with clinically significant prostate cancer. The predictive ability of these parameters was assessed using the receiver operating characteristic curve, leading to the creation of a nomogram. RESULTS: Clinically significant prostate cancer was detected in 68 out of 453 patients with Prostate Imaging Reporting and Data System 3 lesions (15.01%). Among Prostate Imaging Reporting and Data System 3a and 3b patients, 4.78% (3.09% of the total) and 33.75% (11.92% of the total), respectively, had clinically significant prostate cancer. Systematic biopsy improved prostate cancer and clinically significant prostate cancer detection rates by 7.72% and 3.09%, respectively, compared to targeted biopsy. Without systematic biopsy, there would be an undetected rate of 15% for prostate cancer and 8.13% for clinically significant prostate cancer in Prostate Imaging Reporting and Data System 3b patients. Several clinical parameters, including age, prostate-specific antigen density, lesion volume, apparent diffusion coefficient, and digital rectal examination, were statistically significant in the logistic regression analysis for clinically significant prostate cancer. The individual diagnostic accuracies of these parameters for clinically significant prostate cancer were 0.648, 0.645, 0.75, 0.763, and 0.7, respectively, but their combined accuracy improved to 0.866. A well-fit nomogram based on the identified risk factors was constructed (χ2 = 10.254, P = .248). CONCLUSION: The combination of age, prostate-specific antigen density, lesion volume, apparent diffusion coefficient, and digital rectal examination presented a higher diagnostic value for clinically significant prostate cancer than any single parameter in patients with Prostate Imaging Reporting and Data System 3 lesions. Systematic biopsy proved crucial for biopsy-naive patients with Prostate Imaging Reporting and Data System 3 lesions and should not be omitted.


Asunto(s)
Neoplasias de la Próstata , Masculino , Humanos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Antígeno Prostático Específico , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Biopsia Guiada por Imagen/métodos
19.
World J Urol ; 42(1): 249, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38649544

RESUMEN

PURPOSE: Prostate biopsy is central to the accurate histological diagnosis of prostate cancer. In current practice, the biopsy procedure can be performed using a transrectal or transperineal route with different technologies available for targeting of lesions within the prostate. Historically, the biopsy procedure was performed solely by urologists, but with the advent of image-guided techniques, the involvement of radiologists in prostate biopsy has become more common. Herein, we discuss the pros, cons and future considerations regarding their ongoing role. METHODS: A narrative review regarding the current evidence was completed. PubMed and Cochrane central register of controlled trials were search until January 2024. All study types were of consideration if published after 2000 and an English language translation was available. RESULTS: There are no published studies that directly compare outcomes of prostate biopsy when performed by a urologist or radiologist. In all published studies regarding the learning curve for prostate biopsy, the procedure was performed by urologists. These studies suggest that the learning curve for prostate biopsy is between 10 and 50 cases to reach proficiency in terms of prostate cancer detection and complications. It is recognised that many urologists are poorly able to accurately interpret multi parametric (mp)-MRI of the prostate. Collaboration between the specialities is of importance with urology offering the advantage of being involved in prior and future care of the patient while radiology has the advantage of being able to expertly interpret preprocedure MRI. CONCLUSION: There is no evidence to suggest that prostate biopsy should be solely performed by a specific specialty. The most important factor remains knowledge of the relevant anatomy and sufficient volume of cases to develop and maintain skills.


Asunto(s)
Predicción , Biopsia Guiada por Imagen , Próstata , Neoplasias de la Próstata , Urología , Masculino , Humanos , Biopsia Guiada por Imagen/métodos , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Próstata/patología , Próstata/diagnóstico por imagen
20.
Rev Assoc Med Bras (1992) ; 70(3): e20231082, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38656001

RESUMEN

OBJECTIVE: Thoracic ultrasonography is widely used in imaging peripheral lesions and invasive interventional procedures. The aim of this study was to assess the diagnostic value of thoracic ultrasonography-guided transthoracic needle aspiration biopsy and the factors affecting the diagnosis of peripheral tumoral lung lesions. METHODS: The lesion size, biopsy needle type, number of blocks, complications, and pathology results were compared in 83 patients between January 2015 and July 2018. The cases with pathological non-diagnosis and definite pathological diagnosis were determined. For the assessment of the factors affecting diagnosis, the size of the lesions and the biopsy needle type were evaluated. Biopsy preparations containing non-diagnostic atypical cells were referred to a cytopathologist. The effect of the cytopathological examination on the diagnosis was also evaluated. RESULTS: Pathological diagnosis was made in 66.3% of the cases; cell type could not be determined in 22.9% of the cases, and they were referred to a cytopathologist. After the cytopathologist's examination, the diagnosis rate increased to 80.7%. Diagnosis rates were higher when using tru-cut than Chiba and higher in cases with tumor size >2 cm than smaller. CONCLUSION: Thoracic ultrasonography-guided transthoracic needle aspiration biopsy is a preferred approach to the diagnosis of peripheral tumoral lung lesions, given its high diagnostic rate, in addition to being cheap, highly suitable for bedside use, and safe, and the lack of radiation exposure.


Asunto(s)
Biopsia Guiada por Imagen , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Anciano , Biopsia Guiada por Imagen/métodos , Adulto , Ultrasonografía Intervencional/métodos , Anciano de 80 o más Años , Estudios Retrospectivos , Biopsia con Aguja Fina/métodos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA