Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.342
Filtrar
1.
Fr J Urol ; 34(7-8): 102659, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38825320

RESUMEN

BACKGROUND: Advances in chromatography and mass spectrometry have allowed us to develop a novel technique for measuring intraprostatic hormone concentrations directly on prostate needle biopsies, rather than using traditional punch excision. This has significant clinical implications as intraprostatic dihydrotestosterone and testosterone levels could help monitor prostate growth, neoplasia and castration resistance. METHODS: Patients undergoing radical cystoprostatectomy for bladder cancer were prospectively included. Each prostate specimen received one 90mg punch excision and six needle biopsies. Intraprostatic hormones were dosed through gas chromatography-mass spectrometry. RESULTS: We included twenty patients, of which eleven were incidentally diagnosed with prostate cancer; four had ISUP 1 (20%) and seven had ISUP 2 (35%). The prostate biopsy technique was unable to obtain measures for testosterone, Delta-4-androsterone and androstenedione. Tissue concentrations of DHEA, DHT, E1 and E2 can be obtained with no significant difference from the reference established on a punch from a single biopsy core sample. CONCLUSIONS: Our study demonstrates that intraprostatic concentrations of DHEA, DHT, E1 and E2 can be measured without significant difference from the reference established on a single punch excision. This finding opens the way to research on the interactions between endocrinology and prostate oncogenesis and particularly on the mechanisms of resistance to hormone therapies in vivo.


Asunto(s)
Próstata , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía , Próstata/patología , Próstata/cirugía , Próstata/metabolismo , Anciano , Persona de Mediana Edad , Estudios Prospectivos , Cromatografía de Gases y Espectrometría de Masas/métodos , Dihidrotestosterona/metabolismo , Deshidroepiandrosterona/análisis , Deshidroepiandrosterona/administración & dosificación , Biopsia con Aguja/métodos , Testosterona/análisis , Estradiol/análisis
2.
Cardiovasc Intervent Radiol ; 47(7): 1000-1008, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38898149

RESUMEN

PURPOSE: The visibility of biopsy needles in contrast-specific imaging mode can be improved by priming them with an ultrasound contrast agent (previously demonstrated in a phantom model/ex vivo). The purpose of this study was to validate this priming method in a porcine in vivo model. MATERIALS AND METHODS: Using a small syringe, full-core biopsy needles were primed with sulfur hexafluoride, an ultrasound contrast agent, with non-primed needles serving as controls (n = 30 + 30). Liver punctures were performed in a porcine model following intravenous administration of the same ultrasound contrast agent. Needle visibility, both in their entirety and at the tips, was evaluated in split-screen mode using contrast-specific imaging and B-mode (low mechanical index). The assessment included quantitative analysis, calculating the contrast-to-noise ratio, and qualitative evaluation through structured grading by three radiologists. RESULTS: After needle priming, the contrast-to-noise ratio was superior for the needle in its entirety in contrast-specific imaging mode (p < 0.001) and slightly inferior in B-mode (p = 0.008). No differences were observed for the needle tips in either imaging mode. Qualitatively, the needle visibility was deemed clinically superior after needle priming throughout in contrast-specific imaging mode (p < 0.001), whereas no clinically relevant differences in B-mode for either the needle in its entirety (p = 0.11) or the needle tip (p = 1) were observed. CONCLUSION: In this in vivo porcine liver model experiment, priming biopsy needles with ultrasound contrast agent improved needle visibility in contrast-specific imaging mode but slightly reduced it in B-mode. These findings support the method's use for biopsies requiring target visualization in contrast-specific imaging mode.


Asunto(s)
Medios de Contraste , Hígado , Agujas , Animales , Porcinos , Hígado/diagnóstico por imagen , Hígado/patología , Ultrasonografía Intervencional/métodos , Hexafluoruro de Azufre/administración & dosificación , Biopsia con Aguja/métodos , Modelos Animales
3.
Can J Urol ; 31(3): 11886-11891, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38912941

RESUMEN

INTRODUCTION: To define the smallest prostate needle biopsy (PNB) template necessary for accurate tissue diagnosis in men with markedly elevated PSA while decreasing procedural morbidity. MATERIALS AND METHODS: We performed a chart review of 80 men presenting with a newly elevated PSA > 100 ng/mL who underwent biopsy (PNB or metastatic site). For patients who underwent a full 12-core biopsy, simulated templates of 2- to 10-cores were generated by randomly drawing subsets of biopsies from their full-template findings. Templates were iterated to randomize core location and generate theoretical smaller template outcomes. Simulated biopsy results were compared to full-template findings to determine accuracy to maximal Grade Group (GG) diagnosis. RESULTS: Amongst those that underwent PNB, 93% had GG 4 or 5 disease. Twenty-two (40%) underwent a full 12-core biopsy, 20 (37%) a 6-core biopsy, and only 8 (15%) had fewer than six biopsy cores sampled at our hospital. Simulated templates with 2-, 4-, 6-, and 8-cores correctly diagnosed prostate cancer in all patients, and accurately identified the maximal GG in 82%, 91%, 95%, and 97% of patients, respectively. The biopsy locations most likely to detect maximal GG were medial mid and base sites bilaterally. A 4-core template of these sites would have accurately detected the maximal GG in 95% of patients relative to a full 12-core template. CONCLUSIONS: In men presenting with PSA > 100 ng/mL, decreasing from a 12-core to a 4-core prostate biopsy template results in universal cancer detection and minimal under-grading while theoretically decreasing procedural morbidity and cost.


Asunto(s)
Antígeno Prostático Específico , Próstata , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/patología , Antígeno Prostático Específico/sangre , Anciano , Persona de Mediana Edad , Biopsia con Aguja Gruesa/métodos , Próstata/patología , Estudios Retrospectivos , Clasificación del Tumor , Biopsia con Aguja/métodos
4.
Mymensingh Med J ; 33(3): 766-771, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38944719

RESUMEN

Exudative pleural effusion appears as manifestation of underlying specific disease process and pleural biopsy is usually enough to find out the underlying causative disease. The aim of the study was to find out the efficacy of needle biopsy of pleura in the aetiological diagnosis of pleural effusion. This cross-sectional study was conducted for a period of one year from January 2008 to December 2008 in the Department of Medicine, Shaheed Ziaur Rahman Medical College Hospital, Bogura, Bangladesh enrolling 50 subjects with exudative pleural effusion. The cases with transudative pleural effusion were not included. Needle biopsy was done in all the cases. Histopathological reports of pleural biopsy specimen were correlated with other data and analyzed to detect the causes of effusion. Major incidence of malignant effusion occurred between 41 to 70 years of age. No malignant effusion was found before 30 years of age. Incidence of tuberculous and malignant pleural effusion was much more common in males than in females. Sensitivity and specificity of combined pleural biopsy and pleural fluid analysis in the diagnosis of pleural effusion was 97.06% and 100.% for tuberculosis and 81.82% and 100.0% for malignancy. The present study reveals that pleural biopsy was very effective method in the diagnosis of cause of pleural effusion.


Asunto(s)
Derrame Pleural , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Derrame Pleural/etiología , Derrame Pleural/patología , Derrame Pleural/diagnóstico , Adulto , Estudios Transversales , Biopsia con Aguja/métodos , Pleura/patología , Derrame Pleural Maligno/patología , Derrame Pleural Maligno/diagnóstico , Derrame Pleural Maligno/etiología , Sensibilidad y Especificidad , Adolescente
5.
Clin Chest Med ; 45(2): 307-323, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38816090

RESUMEN

The clinical role and use of percutaneous transthoracic needle biopsy (TTNB) and ablation of lung tumors are evolving. Here we discuss important considerations for referring providers, including current and emerging indications supported by guidelines, critical aspects of pre and postprocedure patient management, and expected postprocedure imaging findings.


Asunto(s)
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Biopsia con Aguja/métodos , Pulmón/patología , Pulmón/diagnóstico por imagen , Pulmón/cirugía , Técnicas de Ablación/métodos , Tomografía Computarizada por Rayos X
6.
Eur Rev Med Pharmacol Sci ; 28(9): 3439-3446, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38766800

RESUMEN

OBJECTIVE: Due to infectious complications of transrectal prostate biopsy (TRBx), the transperineal prostate biopsy (TPBx) technique is gaining popularity and is the first-line method in many institutions. We share our experience of the first 100 patients with TPBx, performed using the coaxial needle technique under local anesthesia. PATIENTS AND METHODS: We retrospectively reviewed the records of the first 100 patients who had undergone TPBx between December 2022 and September 2023. Complication rates, cancer detection rates, patient tolerance, and pain response to the TPBx under local anesthesia at different steps of the procedure were collected. RESULTS: The mean age, total prostate-specific antigen (PSA), prostate volume, and PSA density were 64.5±7.5 years, 8.82±12 ng/mL, 58.4±26.4 mL, and 0.17±0.18 ng/mL2. Prostate cancer (PCa) was detected at histopathological evaluation in 51 patients. The mean positive core number and percentage of cancer involvement per core in patients who have PCa were 5.4±3.2 and 68.5±29.1, respectively. The mean pain score during the entire procedure was 2.85±1.48. When the steps are evaluated separately, the mean pain score during the probe placement step, local anesthetic, and sampling steps were 3.35±1.65, 2.54±1.45, and 0.9±0.82, respectively. CONCLUSIONS: Transperineal prostate biopsy with coaxial needle technique under local anesthesia is a well-tolerated procedure with feasible complication rates and patient discomfort.


Asunto(s)
Anestesia Local , Próstata , Neoplasias de la Próstata , Humanos , Masculino , Persona de Mediana Edad , Anestesia Local/efectos adversos , Anestesia Local/métodos , Estudios Retrospectivos , Anciano , Neoplasias de la Próstata/patología , Próstata/patología , Perineo , Antígeno Prostático Específico/sangre , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos
7.
Folia Med (Plovdiv) ; 66(2): 179-187, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38690812

RESUMEN

INTRODUCTION: Evaluation of patients with peripheral lung lesions and lesions of the chest wall and mediastinum is challenging. The nature of the lesion identified by imaging studies can be determined by histological evaluation of biopsies. An important place in this direction is the ever-increasing popularity among thoracic surgeons of the transthoracic biopsy with a cutting needle under ultrasound control (US-TTCNB).


Asunto(s)
Mediastino , Pared Torácica , Humanos , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Pulmón/patología , Pulmón/diagnóstico por imagen , Enfermedades Pulmonares/patología , Enfermedades Pulmonares/diagnóstico por imagen , Enfermedades Pulmonares/etiología , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/diagnóstico por imagen , Mediastino/patología , Mediastino/diagnóstico por imagen , Pared Torácica/diagnóstico por imagen , Pared Torácica/patología
8.
Technol Health Care ; 32(S1): 313-320, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38669497

RESUMEN

BACKGROUND: With the widespread use of low-dose spiral computed tomography (LDCT) and increasing awareness of personal health, the detection rate of pulmonary nodules is steadily rising. OBJECTIVE: To evaluate the success rate and safety of two different models of Hook-Wire needle localization procedures for pulmonary small nodule biopsy. METHODS: Ninety-four cases with a total of 97 pulmonary small nodules undergoing needle localization biopsy were retrospectively analyzed. The cases were divided into two groups: Group A, using breast localization needle steel wire (Bard Healthcare Science Co., Ltd.); Group B, using disposable pulmonary nodule puncture needle (SensCure Biotechnology Co., Ltd.). All patients underwent video-assisted thoracoscopic surgery (VATS) for nodule removal on the same day after localization and biopsy. The puncture localization operation time, success rate, complications such as pulmonary hemorrhage, pneumothorax, hemoptysis, and postoperative comfort were observed and compared. RESULTS: In Group A, the average localization operation time for 97 nodules was 15.47 ± 5.31 minutes, with a success rate of 94.34%. The complication rate was 71.69% (12 cases of pneumothorax, 35 cases of pulmonary hemorrhage, 2 cases of hemoptysis), and 40 cases of post-localization discomfort were reported. In Group B, the average localization operation time was 25.32 ± 7.83 minutes, with a 100% success rate. The complication rate was 29.55% (3 cases of pneumothorax, 15 cases of pulmonary hemorrhage, 0 cases of hemoptysis), and 3 cases reported postoperative discomfort. According to the data analysis in this study, Group B had a lower incidence of puncture-related complications than Group A, along with a higher success rate and significantly greater postoperative comfort. CONCLUSIONS: The disposable pulmonary nodule puncture needle is safer and more effective in pulmonary small nodule localization biopsy, exhibiting increased comfort compared to the breast localization needle. Additionally, the incidence of complications is significantly lower.


Asunto(s)
Nódulo Pulmonar Solitario , Cirugía Torácica Asistida por Video , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Cirugía Torácica Asistida por Video/métodos , Cirugía Torácica Asistida por Video/instrumentación , Nódulo Pulmonar Solitario/cirugía , Nódulo Pulmonar Solitario/patología , Nódulo Pulmonar Solitario/diagnóstico por imagen , Anciano , Adulto , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Biopsia con Aguja/métodos , Biopsia con Aguja/instrumentación , Agujas , Tempo Operativo , Tomografía Computarizada Espiral/métodos
9.
Respiration ; 103(7): 388-396, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38599179

RESUMEN

INTRODUCTION: There is no consensus regarding the most appropriate management of suspected malignant pulmonary ground-glass nodules (GGNs). OBJECTIVE: We aimed to explore the feasibility and safety of synchronous computed tomography-guided percutaneous transthoracic needle biopsy (PTNB) and microwave ablation (MWA) for patients highly suspicious of having malignant GGNs. METHODS: We retrospectively reviewed medical records between July 2020 and April 2023 from our medical center. Eligible patients synchronously underwent PTNB and MWA (either MWA immediately after PTNB [PTNB-first group] or PTNB immediately after MWA [MWA-first group]) at the the physician's discretion. We analyzed the rate of definitive diagnosis and technical success, the length of hospital stay, the postoperative efficacy, and periprocedural complications. RESULTS: Of 65 patients who were enrolled, the rate of definitive diagnosis was 86.2%, which did not differ when stratified by the tumor size, the consolidation-to-tumor ratio, or the sequence of the two procedures (all p > 0.05). The diagnostic rate of malignancy was 83.1%. After the median follow-up duration of 18.5 months, the local control rate was 98.2% and the rate of completed ablation was 48.2%. The rate of perioperative minor and major complications was 44.6% and 6.2%, respectively. The most common adverse events included pain, cough, and mild hemorrhage. Mild hemorrhage took place significantly less frequently in the MWA-first group than in the PTNB-first group (16.7% vs. 45.5%, p < 0.05). CONCLUSION: Synchronous PTNB and MWA are feasible and well tolerated for patients highly suspicious of having malignant GGNs, providing an alternative option for patients who are ineligible for surgical resection.


Asunto(s)
Biopsia Guiada por Imagen , Neoplasias Pulmonares , Microondas , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Persona de Mediana Edad , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Estudios Retrospectivos , Microondas/uso terapéutico , Anciano , Biopsia Guiada por Imagen/métodos , Estudios de Factibilidad , Biopsia con Aguja/métodos , Nódulos Pulmonares Múltiples/patología , Nódulos Pulmonares Múltiples/cirugía , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Adulto
10.
Lancet Microbe ; 5(7): 707-716, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38604206

RESUMEN

Post-mortem examinations continue to play a crucial role in understanding the epidemiology and pathogenesis of infectious diseases. However, the perceived infection risk can preclude traditional, invasive, complete diagnostic autopsy. Post-mortem examination is especially important in emerging infectious diseases with potentially unknown infection risks, but rapid acquisition of good quality tissue samples is needed as part of the scientific and public health response. Needle biopsy post-mortem is a minimally invasive, rapid, closed-body autopsy technique that was originally developed to minimise the infection risk to practitioners. Since its inception, needle biopsy post-mortem has also been used as a technique to support complete diagnostic autopsy provision in poorly resourced regions and to facilitate post-mortem examinations in communities that might have religious or cultural objections to an invasive autopsy. This Review analyses the evolution and applicability of needle biopsy post-mortem in investigating endemic and emerging infectious diseases.


Asunto(s)
Autopsia , Enfermedades Transmisibles , Humanos , Autopsia/métodos , Enfermedades Transmisibles/patología , Enfermedades Transmisibles/epidemiología , Biopsia con Aguja/métodos
11.
Zhonghua Yi Xue Za Zhi ; 104(16): 1403-1409, 2024 Apr 23.
Artículo en Chino | MEDLINE | ID: mdl-38644291

RESUMEN

Objective: To investigate the safety and accuracy of CT-guided intracranial puncture biopsy and the possible influencing factors of postoperative bleeding complications. Methods: A case series study. A retrospective analysis was conducted on 101 patients who underwent CT-guided intracranial puncture biopsy at the First Affiliated Hospital of Zhengzhou University from January 2017 to December 2021. The basic data of patients and the safety and accuracy of CT-guided intracranial puncture biopsy were analyzed statistically. Univariate and multivariate logistic regression analysis were used to screen the influencing factors of bleeding complications in CT-guided intracranial puncture biopsy, and the bleeding complications in glioma subgroup were analyzed. Results: Among the 101 patients, 53 were males and 48 were females, aged (53.7±17.2) years. The average diameter of intracranial lesions was (3.5±1.4) cm, while the vertical distance from the lesion to the meninges was (2.4±1.7) cm. The needle's intracranial depth reached (3.2±1.8) cm, with adjustments averaging (3±1) occurrences and an average procedural duration of (40.2±12.9) minutes. Pathological diagnoses included glioma (36 cases), gliosis (3 cases), lymphoma (32 cases), metastatic tumors (7 cases), inflammatory lesions (13 cases), and 10 indeterminate cases. The positive rate of puncture pathology was 90.1% (91/101), and the diagnostic coincidence rate was 94.0% (78/83). The incidence of bleeding complications in CT-guided intracranial puncture biopsy was 26.7% (27/101), of which 23 cases had small intratoma or needle path bleeding, 4 cases had massive bleeding, and 2 cases died. The patients were divided into bleeding group (n=27) and no bleeding group (n=74), according to the presence or absence of bleeding. The results of univariate logistic regression analysis showed that thrombin time≥15 s and the number of needle adjustment were the factors affecting the occurrence of bleeding complications (both P<0.05), and the results of multivariate logistic regression showed that thrombin time≥15 s was the related factor for bleeding. Patients with thrombin time≥15 s had a 3.045 times higher risk of bleeding than those with thrombin time<15 s (OR=3.045,95%CI:1.189-7.799,P=0.020). Among the 101 patients, 36 cases of midbrain glioma were divided into low-grade glioma group (n=11) and high-grade glioma group (n=25) according to the pathological grade. Subgroup analysis showed that the risk of bleeding for high-grade gliomas was 9.231 times higher than that for low-grade gliomas (OR=9.231,95%CI:1.023-83.331,P=0.031). Conclusions: CT-guided intracranial puncture biopsy is safe and feasible with high accuracy. Complication rates are associated with thrombin time≥15 s, especially high-grade glioma, which increases the risk of postoperative bleeding.


Asunto(s)
Neoplasias Encefálicas , Biopsia Guiada por Imagen , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Glioma/patología , Adulto , Anciano , Encéfalo/patología , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos
12.
Curr Oncol ; 31(2): 900-917, 2024 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-38392061

RESUMEN

Biopsy is a pivotal component in the diagnostic process of bone and soft tissue tumors. The objective is to obtain adequate tissue without compromising local tumor dissemination and the patient's survival. This review explores contemporary principles and practices in musculoskeletal biopsies, emphasizing the critical role of diagnostic accuracy while also delving into the evolving landscape of liquid biopsies as a promising alternative in the field. A thorough literature search was done in PubMed and Google Scholar as well as in physical books in libraries to summarize the available biopsy techniques for musculoskeletal tumors, discuss the available methods, risk factors, and complications, and to emphasize the challenges related to biopsies in oncology. Research articles that studied the basic principles and specialized techniques of biopsy techniques in tumor patients were deemed eligible. Their advantages and disadvantages, technical and pathophysiological mechanisms, and possible risks and complications were reviewed, summarized, and discussed. An inadequately executed biopsy may hinder diagnosis and subsequently impact treatment outcomes. All lesions should be approached with a presumption of malignancy until proven otherwise. Liquid biopsies have emerged as a potent non-invasive tool for analyzing tumor phenotype, progression, and drug resistance and guiding treatment decisions in bone sarcomas and metastases. Despite advancements, several barriers remain in biopsies, including challenges related to costs, scalability, reproducibility, and isolation methods. It is paramount that orthopedic oncologists work together with radiologists and pathologists to enhance diagnosis, patient outcomes, and healthcare costs.


Asunto(s)
Neoplasias Óseas , Enfermedades Musculoesqueléticas , Neoplasias de los Tejidos Blandos , Humanos , Biopsia con Aguja/métodos , Reproducibilidad de los Resultados , Biopsia
13.
Eur J Radiol ; 173: 111373, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38364588

RESUMEN

OBJECTIVE: This study aims to analyze our initial findings regarding CEM-guided stereotactic vacuum-assisted biopsy for MRI-only detected lesions and compare biopsy times by MRI-guided biopsy. MATERIALS AND METHODS: In this retrospective analysis, CEM-guided biopsies of MRI-only detected breast lesions from December 2021 to June 2023were included. Patient demographics, breast density, lesion size, background parenchymal enhancement on CEM, lesion positioning, procedure duration, and number of scout views were documented. Initially, seven patients had CEM imaging before biopsy; for later cases, CEM scout views were used for simultaneous lesion depiction and targeting. RESULTS: Two cases were excluded from the initial 28 patients with 29 lesions resulting in a total of 27 lesions in 26 women (mean age:44.96 years). Lesion sizes ranged from 4.5 to 41 mm, with two as masses and the remaining as non-mass enhancements. Histopathological results identified nine malignancies (33.3 %, 9/27), including invasive cancers (55.6 %, 5/9) and DCIS (44.4 %, 4/9). The biopsy PPV rate was 33.3 %. Benign lesions comprised 66.7 %, with 22.2 % high-risk lesions. The biopsy success rate was 93.1 % (27/29), and minor complications occurred in seven cases (25.9 %, 7/27), mainly small hematomas and one vasovagal reaction (3.7 %, 1/27). Median number of scout views required was 2, with no significant differences between cases with or without prior CEM (P = 0.8). Median duration time for biopsy was 14 min, significantly shorter than MRI-guided bx at the same institution (P < 0.001) by 24 min with predominantly upright positioning of the patient (88.9 %) and horizontal approach of the needle (92.6 %). CONCLUSION: This study showed that CEM-guided biopsy is a feasible and safe alternative method and a faster solution for MRI-only detected enhancing lesions and can be accurately performed without the need for prior CEM imaging.


Asunto(s)
Neoplasias de la Mama , Mamografía , Femenino , Humanos , Adulto , Persona de Mediana Edad , Estudios Retrospectivos , Biopsia/métodos , Biopsia con Aguja/métodos , Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/diagnóstico por imagen
14.
Acta Radiol ; 65(5): 432-440, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38342990

RESUMEN

BACKGROUND: Computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) is not recommended as the diagnostic modality of choice for anterior mediastinal lymphoma, despite its advantages of minimal invasiveness and easy accessibility. PURPOSE: To identify the modifiable risk factors for non-diagnostic results from CT-guided PTNB for anterior mediastinal lymphoma. MATERIAL AND METHODS: This retrospective study identified CT-guided PTNB for anterior mediastinal lesions diagnosed as lymphoma between May 2007 and December 2021. The diagnostic sensitivity and complications were investigated. The appropriateness of PTNB targeting was evaluated using positron emission tomography (PET)/CT and images from intra-procedural CT-guided PTNB. Targeting was considered inappropriate when the supposed trajectory of the cutting needle was within a region of abnormally low metabolism. The risk factors for non-diagnostic results were determined using logistic regression analysis. RESULTS: A total of 67 PTNBs in 60 patients were included. The diagnostic sensitivity for lymphoma was 76.1% (51/67), with an immediate complication rate of 4.5% (3/67). According to the PET/CT images, PTNB targeting was inappropriate in 10/14 (71.4%) of the non-diagnostic PTNBs but appropriate in all diagnostic PTNBs (P <0.001). Inappropriate targeting was the only significant risk factor for non-diagnostic results (odds ratio = 203.69; 95% confidence interval = 8.17-999.99; P = 0.001). The number of specimen acquisitions was not associated with non-diagnostic results (P = 0.40). CONCLUSIONS: Only inappropriate targeting of the non-viable portion according to PET/CT was an independent risk factor for non-diagnostic results. Acquiring PET/CT scans before biopsy and targeting the viable portion on PET/CT may help improve the diagnostic sensitivity of PTNB.


Asunto(s)
Biopsia Guiada por Imagen , Linfoma , Neoplasias del Mediastino , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Masculino , Femenino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Persona de Mediana Edad , Estudios Retrospectivos , Neoplasias del Mediastino/diagnóstico por imagen , Neoplasias del Mediastino/patología , Biopsia Guiada por Imagen/métodos , Adulto , Linfoma/diagnóstico por imagen , Linfoma/patología , Anciano , Biopsia con Aguja/métodos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Adulto Joven , Anciano de 80 o más Años , Radiografía Intervencional/métodos , Mediastino/diagnóstico por imagen
15.
Minim Invasive Ther Allied Technol ; 33(3): 171-175, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38315057

RESUMEN

INTRODUCTION: The purpose is to clarify the safety and clinical contribution of computed tomography (CT)-guided percutaneous needle-biopsy for patients with cervical spine lesion. MATERIAL AND METHODS: Between June 2015 and August 2022, CT-guided percutaneous needle biopsies were performed for 15 cervical spine lesions of 15 patients (8 male, 7 female; 2-81 years old). The technical success, clinical contribution, and safety were evaluated. Technical success was defined as the completion of the biopsy procedure. Clinical contribution was defined as any contribution to the therapeutic strategy. Safety was assessed by the Common Terminology Criteria for Adverse Events, version 5.0. RESULTS: The technical success rate was 100%. In all 15 patients, nontarget organs (e.g., major vessels, spinal cord) could be avoided. The post-biopsy histological diagnoses were myeloma (n = 2), metastatic adenocarcinoma (n = 2), chordoma (n = 2), Langerhans cell histiocytosis (n = 3), and one case each of malignant lymphoma, schwannoma, pyogenic spondylitis, non-pyogenic spondylitis, degenerative change, and non-pathological fracture. All of these diagnoses contributed to the therapeutic strategy decisions. One case of grade 2 pain was observed, but no complications with grade 3 or more were observed during or after the biopsies. CONCLUSION: CT-guided percutaneous needle biopsies for cervical spine lesions were safe and clinically beneficial.


Asunto(s)
Vértebras Cervicales , Biopsia Guiada por Imagen , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Biopsia Guiada por Imagen/métodos , Biopsia Guiada por Imagen/efectos adversos , Anciano de 80 o más Años , Adulto , Adolescente , Adulto Joven , Niño , Preescolar , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos , Estudios Retrospectivos , Enfermedades de la Columna Vertebral/patología
16.
Cardiovasc Intervent Radiol ; 47(5): 604-612, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38263525

RESUMEN

PURPOSE: To determine whether instillation of normal saline solution for sealing the needle track reduces incidence of pneumothorax and chest tube placement after computed tomography-guided percutaneous lung biopsy. MATERIALS AND METHODS: A total of 242 computed tomography-guided percutaneous lung biopsies performed at a single institution were retrospectively reviewed, including 93 biopsies in which the needle track was sealed by instillation of 3-5 ml of normal saline solution during needle withdrawal (water seal group) and 149 biopsies without sealing (control group). Patient and lesion characteristics, procedure-specific variables, pneumothorax and chest tube placement rates were recorded. RESULTS: Baseline characteristics were comparable in both groups. There was a statistically significant decrease in the pneumothorax rate (19.4% [18/93] vs. 40.9% [61/149]; p < 0.001) and a numerically lower chest tube placement rate without significant reduction (4.3% [4/93] vs. 10.7% [16/149]; p = 0.126) with using normal saline instillation for sealing the needle track versus not using sealant material. Using a multiple logistic regression analysis, using normal saline instillation to seal the needle track, having a senior radiologist as operator of the procedure and putting patients in prone position were significantly associated with a decreased risk of pneumothorax. The presence of emphysema along the needle track was significantly associated with an increased risk of pneumothorax. No complication was observed due to normal saline injection. CONCLUSION: Normal saline solution instillation for sealing the needle track after computed tomography-guided percutaneous lung biopsy is a simple, low-cost and safe technique resulted in significantly decreased pneumothorax occurrence and a numerically lower chest tube placement rate, and might help to reduce both hospitalization risks and costs for the healthcare system. Level of evidence 3 Non-controlled retrospective cohort study.


Asunto(s)
Biopsia Guiada por Imagen , Pulmón , Neumotórax , Radiografía Intervencional , Solución Salina , Tomografía Computarizada por Rayos X , Humanos , Neumotórax/etiología , Neumotórax/prevención & control , Neumotórax/epidemiología , Femenino , Masculino , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Persona de Mediana Edad , Solución Salina/administración & dosificación , Incidencia , Anciano , Biopsia Guiada por Imagen/métodos , Biopsia Guiada por Imagen/efectos adversos , Pulmón/diagnóstico por imagen , Pulmón/patología , Radiografía Intervencional/métodos , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos , Tubos Torácicos , Adulto
17.
Ultrasonics ; 138: 107233, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38171228

RESUMEN

Breast cancer has become the most common cancer worldwide, and early screening improves the patient's survival rate significantly. Although pathology with needle-based biopsy is the gold standard for breast cancer diagnosis, it is invasive, painful, and expensive. Meanwhile it makes patients suffer from misplacement of the needle, resulting in misdiagnosis and further assessment. Ultrasound imaging is non-invasive and real-time, however, benign and malignant tumors are hard to differentiate in grayscale B-mode images. We hypothesis that breast tumors exhibit characteristic properties, which generates distinctive spectral patterns not only in scattering, but also during propagation. In this paper, we propose a breast tumor classification method that evaluates the spectral pattern of the tissues both inside the tumor and beneath it. First, quantitative ultrasonic parameters of these spectral patterns were calculated as the representation of the corresponding tissues. Second, parameters were classified by the K-Nearest Neighbor machine learning model. This method was verified with an open access dataset as a reference, and applied to our own dataset to evaluate the potential for tumors assessment. With both datasets, the proposed method demonstrates accurate classification of the tumors, which potentially makes it unnecessary for certain patients to take the biopsy, reducing the rate of the painful and expensive procedure.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Ultrasonografía , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Mama , Biopsia , Biopsia con Aguja/métodos
18.
Clin Radiol ; 79(4): 263-271, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38220515

RESUMEN

AIM: To investigate the diagnostic performance of computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) for thymic epithelial tumours (TETs) and the complication rate after PTNB including seeding after PTNB. MATERIALS AND METHODS: This retrospective study identified PTNBs for anterior mediastinal lesions between May 2007 and September 2021. The diagnostic performance for TETs and complications were investigated. The concordance of the histological grades of TETs between PTNB and surgery was evaluated. The factors associated with pleural seeding after PTNB were determined using Cox regression analysis. RESULTS: Of 387 PTNBs, 235 PTNBs from 225 patients diagnosed as TETs (124 thymomas and 101 thymic carcinomas) and 150 PTNBs from 133 patients diagnosed as other than TETs were included. The sensitivity, specificity, and accuracy for TETs were 89.4% (210/235), 100% (210/210), and 93.5% (360/385), respectively, with an immediate complication rate of 4.4% (17/385). The concordance rate of the histological grades between PTNB and surgery was 73.3% (77/105) after excluding uncategorised types of thymomas. During follow-up after PTNB (median duration, 38.8 months; range, 0.3-164.6 months), no tract seeding was observed. Pleural seeding was observed in 26 patients. Thymic carcinoma (hazard ratio [HR], 5.94; 95% confidence interval [CI], 2.07-17.08; p=0.001) and incomplete resection (HR, 3.29; 95% CI, 1.20-9.02; p=0.02) were associated with pleural seeding, while the biopsy approach type (transpleural versus parasternal) was not associated (p=0.12). CONCLUSIONS: Pretreatment biopsy for TETs was accurate and safe and may be considered for diagnosing TETs, particularly when the diagnosis is challenging and histological diagnosis is mandatory.


Asunto(s)
Neoplasias Glandulares y Epiteliales , Timoma , Neoplasias del Timo , Humanos , Timoma/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Biopsia con Aguja/métodos , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Neoplasias del Timo/diagnóstico por imagen , Neoplasias Glandulares y Epiteliales/diagnóstico por imagen
19.
Korean J Radiol ; 25(2): 157-165, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38288896

RESUMEN

OBJECTIVE: We aimed to evaluate the clinical and imaging factors associated with hemorrhagic complications and patient discomfort following ultrasound (US)-guided breast biopsy. MATERIALS AND METHODS: We prospectively enrolled 94 patients who were referred to our hospital between June 2022 and December 2022 for US-guided breast biopsy. After obtaining informed consent, two breast radiologists independently performed US-guided breast biopsy and evaluated the imaging findings. A hemorrhagic complication was defined as the presence of bleeding or hematoma on US. The patients rated symptoms of pain, febrile sensation, swelling at the biopsy site, and dyspnea immediately, 20 minutes, and 2 weeks after the procedure on a visual analog scale, with 0 for none and 10 for the most severe symptoms. Additional details recorded included those of nausea, vomiting, bleeding, bruising, and overall satisfaction score. We compared the clinical symptoms, imaging characteristics, and procedural features between patients with and those without hemorrhagic complications. RESULTS: Of 94 patients, 7 (7%) developed hemorrhagic complications, while 87 (93%) did not. The complication resolved with 20 minutes of manual compression, and no further intervention was required. Vascularity on Doppler examination (P = 0.008), needle type (P = 0.043), and lesion location (P < 0.001) were significantly different between the groups. Patients with hemorrhagic complications reported more frequent nausea or vomiting than those without hemorrhagic complications (29% [2/7] vs. 2% [2/87], respectively; P = 0.027). The overall satisfaction scores did not differ between the two groups (P = 0.396). After 2 weeks, all symptoms subsided, except bruising (50% 2/4 in the complication group and 25% [16/65] in the no-complication group). CONCLUSION: US-guided breast biopsy is a safe procedure with a low complication rate. Radiologists should be aware of hemorrhagic complications, patient discomfort, and overall satisfaction related to this procedure.


Asunto(s)
Biopsia Guiada por Imagen , Ultrasonografía Intervencional , Humanos , Estudios Prospectivos , Biopsia con Aguja/métodos , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Ultrasonografía Intervencional/métodos , Atención Dirigida al Paciente , Náusea/etiología , Vómitos/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...