Clin Nucl Med ; 49(8): 748-749, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38967506

RESUMEN

ABSTRACT: A 51-year-old woman with a 2-mm-Breslow-thickness melanoma on her arm had 99mTc-nanocolloid lymphoscintigraphy to localize the associated sentinel lymph node. A single axillary node was identified, and histology confirmed a micrometastasis of breast tissue origin. Imaging of the patient's breasts and subsequent biopsy confirmed ipsilateral stage III breast cancer, which was treated with lumpectomy and axillary node clearance. This is the first reported case of an incidental solid cancer diagnosis from a sentinel lymph node biopsy undertaken for a different tumor origin. This illustrates the importance of recognizing overlapping lymphatic distribution of sentinel lymph nodes, which can drain multiple organs.


Asunto(s)
Brazo , Neoplasias de la Mama , Hallazgos Incidentales , Linfocintigrafia , Melanoma , Neoplasias Cutáneas , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Humanos , Femenino , Persona de Mediana Edad , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Melanoma/diagnóstico por imagen , Melanoma/patología , Neoplasias Cutáneas/diagnóstico por imagen , Neoplasias Cutáneas/patología , Brazo/diagnóstico por imagen , Melanoma Cutáneo Maligno , Biopsia del Ganglio Linfático Centinela
2.
Radiography (Lond) ; 30(4): 1035-1040, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38723444

RESUMEN

INTRODUCTION: During Computed Tomography (CT) scans of the Thorax-Abdomen-Pelvis (TAP) the patient's arms should be positioned above the head to obtain optimal image quality and expose the patient to the lowest possible radiation dose. This may be impossible with patients with shoulder problems leading to arms being positioned in other ways. This study aimed to investigate differences in objective image quality and estimated effective dose (E), when positioning the arms below shoulder level in CT-TAP. METHODS: An anthropomorphic phantom with cadaver arms was used. Four arm positions were tested: Along the torso (A), on the pelvis (B), on a pillow on the pelvis (C), and one arm on pillow on the pelvis and the other arm on the pelvis (D). A Siemens SOMATOM Definition Flash CT-scanner with CareDose 4D was used. The dose length product was read to estimate E. Image quality was assessed objectively by measuring noise within the region of interest in the liver and urinary bladder. RESULTS: Significant differences in E between all arm positions were seen (p = 0.005). The lowest E was obtained in position C, reducing E by 8.42%. Position A provided the best image quality but the highest E. CONCLUSION: This study showed no unequivocal optimal positioning of arms in CT-TAP. Position A provided the best object image quality, while position C yielded the lowest E. These results may impact the planning of diagnostic CT where positioning of arms may influence optimal image quality and radiation dose. IMPLICATION FOR PRACTICE: This study illustrates tendencies for objective image quality and E when arms are positioned below shoulder level. Further research is needed to assess the clinical relevance with the diagnostic potential.


Asunto(s)
Brazo , Posicionamiento del Paciente , Fantasmas de Imagen , Dosis de Radiación , Radiografía Abdominal , Radiografía Torácica , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Brazo/diagnóstico por imagen , Radiografía Torácica/métodos , Radiografía Abdominal/métodos , Cadáver
3.
Sci Data ; 11(1): 536, 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38796545

RESUMEN

Spectral imaging has the potential to become a key technique in interventional medicine as it unveils much richer optical information compared to conventional RBG (red, green, and blue)-based imaging. Thus allowing for high-resolution functional tissue analysis in real time. Its higher information density particularly shows promise for the development of powerful perfusion monitoring methods for clinical use. However, even though in vivo validation of such methods is crucial for their clinical translation, the biomedical field suffers from a lack of publicly available datasets for this purpose. Closing this gap, we generated the SPECTRAL Perfusion Arm Clamping dAtaset (SPECTRALPACA). It comprises ten spectral videos (∼20 Hz, approx. 20,000 frames each) systematically recorded of the hands of ten healthy human participants in different functional states. We paired each spectral video with concisely tracked regions of interest, and corresponding diffuse reflectance measurements recorded with a spectrometer. Providing the first openly accessible in human spectral video dataset for perfusion monitoring, our work facilitates the development and validation of new functional imaging methods.


Asunto(s)
Piel , Humanos , Piel/irrigación sanguínea , Piel/diagnóstico por imagen , Grabación en Video , Mano/irrigación sanguínea , Brazo/irrigación sanguínea , Brazo/diagnóstico por imagen
4.
Korean J Radiol ; 25(5): 449-458, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38685735

RESUMEN

Selective fascicular involvement of the median nerve trunk above the elbow leading to anterior interosseous nerve (AIN) syndrome is a rare form of peripheral neuropathy. This condition has recently garnered increased attention within the medical community owing to advancements in imaging techniques and a growing number of reported cases. In this article, we explore the topographical anatomy of the median nerve trunk and the clinical features associated with AIN palsy. Our focus extends to unique manifestations captured through MRI and ultrasonography (US) studies, highlighting noteworthy findings, such as nerve fascicle swelling, incomplete constrictions, hourglass-like constrictions, and torsions, particularly in the posterior/posteromedial region of the median nerve. Surgical observations have further enhanced the understanding of this complex neuropathic condition. High-resolution MRI not only reveals denervation changes in the AIN and median nerve territories but also illuminates these alterations without the presence of compressing structures. The pivotal roles of high-resolution MRI and US in diagnosing this condition and guiding the formulation of an optimal treatment strategy are emphasized.


Asunto(s)
Imagen por Resonancia Magnética , Nervio Mediano , Ultrasonografía , Humanos , Imagen por Resonancia Magnética/métodos , Nervio Mediano/diagnóstico por imagen , Ultrasonografía/métodos , Brazo/inervación , Brazo/diagnóstico por imagen , Neuropatía Mediana/diagnóstico por imagen , Síndrome
5.
J Orthop Surg Res ; 19(1): 193, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38504340

RESUMEN

BACKGROUND: The importance of several scapulothoracic muscles, including trapezius and serratus anterior, in maintaining physiological scapula kinematics has been highlighted in the past. However, the relationship between the scapula and the latissimus dorsi muscle remains unclear. Our clinical surgical observation is that the latissimus dorsi does not directly attach but rather runs superficial to the inferior angle of the scapula. Based on this observation, we hypothesise that the latissimus dorsi creates a dynamic track on which the scapula glides under the muscle belly during elevation of the arm, creating the latissimus-scapula overlap (LSO). METHODS: All consecutive patients who had a whole-body computed tomography scan (CT) in case of polytrauma evaluation between 2018 and 2021, with complete depiction of the scapula and latissimus dorsi muscle, were analysed. 150 shoulders in 90 patients with arms up were matched according to their age (within five years), gender, and affected side with 150 shoulders in 88 patients with arms down. Patients with pathologies of the upper extremities or thorax that potentially could alter LSO measurements were excluded. LSO was calculated as a ratio of the measured area of the latissimus dorsi projection on the scapula and the total scapula area. RESULTS: The mean age of the 178 patients (48 females; 13 males) was 60 years. The arms-up group showed a significantly higher LSO than the arms-down group (19.9 ± 6.3% vs. 2.7 ± 2.2%; p < 0.0001). In the arms-up group, approximately one fifth of the scapula was overlapped inferiorly by the muscle belly of the latissimus dorsi, contrary to the almost non-existing LSO in the arms-down group. CONCLUSION: With arms up, humans show a significantly higher LSO in comparison to arms down indicating that the latissimus dorsi indeed creates a dynamic track on which the scapula is forced to travel during abduction of the arm. This finding of increased LSO during the elevation of the arm warrants further consideration of the role of the latissimus dorsi in scapula kinematics and potentially scapular dyskinesis. LEVEL OF EVIDENCE: Level two diagnostic study.


Asunto(s)
Anomalías Congénitas , Escápula/anomalías , Articulación del Hombro/anomalías , Músculos Superficiales de la Espalda , Masculino , Femenino , Humanos , Preescolar , Músculos Superficiales de la Espalda/diagnóstico por imagen , Brazo/diagnóstico por imagen , Escápula/cirugía , Hombro
6.
Radiography (Lond) ; 30(2): 681-687, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38364708

RESUMEN

INTRODUCTION: This retrospective cohort study examined the effects of the crossed raised arm (CRA) position in contrast-enhanced computed tomography (CECT) on contrast medium influx and image quality relative to the conventional position. METHODS: Contrast medium influx into the collateral veins on CECT images was evaluated in 92 participants. The CT values of the pulmonary artery, descending aorta, and spleen were obtained in both positions and compared. Anatomical changes in the diameters and area of the subclavian vein and costoclavicular distance were also analyzed. RESULTS: Contras 27 and 6 patients in the conventional and CRA positions, respectively. The influx risk ratio in the CRA position versus that in the conventional position was 0.22 (95% confidence interval, 0.10-0.51). Elevations in the median CT value of the pulmonary artery, descending aorta, and spleen in the CRA position were 7.0% (p < .001), 7.4% (p < .001), and 9.8% (p < .001), respectively. Enlargements in the major and minor diameters of the subclavian vein, subclavian vein area, and costoclavicular distance in the CRA position versus those in the conventional position were 19.3% (p < .001), 28.1% (p < .001), 53.6%, and 30.0% (p < .001), respectively. CONCLUSION: The CRA position effectively prevented contrast medium influx into the collateral veins due to SVS and increased CT values in the target organs in CECT. The diameters and area of the subclavian vein and costoclavicular distance were enlarged at the thoracic outlet, which improved the flow of the contrast medium into the targeted organs. IMPLICATIONS FOR PRACTICE: The CRA position can contribute to obtaining better CECT images during common clinical assessments at no additional cost.


Asunto(s)
Brazo , Tomografía Computarizada por Rayos X , Humanos , Brazo/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Abdomen
7.
Radiography (Lond) ; 30(1): 416-421, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38181465

RESUMEN

INTRODUCTION: This study aimed to investigate and compare the effective dose (ED) delivered by computed tomography (CT) in whole-body positron emission tomography/CT (WB-PET/CT) scans between patients positioned with their arms-raised and those with their arms-lowered during the scan on a large population. METHODS: The retrospective study involved 785 oncology patients who underwent WB-PET/CT scans with 18F-FDG between January and June 2019. Exclusion criteria were applied, resulting in a final analysis of data from 732 adult patients. All of the patients were measured height and weight, and the ED from CT in WB-PET/CT was estimated using the dose length product value and a conversion factor. Statistical analyses were conducted to explore relationships between factors and the ED. Linear regression analysis was performed to investigate connections between weight and ED, and height and ED. Multiple linear regression was used to predict ED based on sex, weight, and arm position. RESULTS: The arm-lowered group had a higher ED than the arm-raised group, and the median dose was 1.1 times higher in the arm-lowered group. The difference in ED between the two groups was found to be greater with higher body weight. Arm-position (ß = 0.460), sex (ß = -0.190), and weight (ß = 0.057) were significant predictors of ED. CONCLUSION: This study demonstrated that arm position, sex, and weight were significant factors influencing the ED from CT scans in WB-PET/CT. IMPLICATIONS FOR PRACTICE: The research underscores the importance of considering these factors when evaluating radiation exposure in clinical practice, particularly for patients undergoing WB-CT imaging. These findings contribute to a better understanding of the radiation dosimetry associated with different patient positions during WB-PET/CT scans.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adulto , Humanos , Brazo/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones , Radiofármacos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Masculino , Femenino
8.
Artículo en Inglés | MEDLINE | ID: mdl-38083105

RESUMEN

The creation of unique control methods for a hand prosthesis is still a problem that has to be addressed. The best choice of a human-machine interface (HMI) that should be used to enable natural control is still a challenge. Surface electromyography (sEMG), the most popular option, has a variety of difficult-to-fix issues (electrode displacement, sweat, fatigue). The ultrasound imaging-based methodology offers a means of recognising complex muscle activity and configuration with a greater SNR and less hardware requirements as compared to sEMG. In this study, a prototype system for high frame rate ultrasound imaging for prosthetic arm control is proposed. Using the proposed framework, a virtual robotic hand simulation is developed that can mimic a human hand as illustrated in the link: https://youtu.be/LBcwQ0xzQK0. The proposed classification model simulating four hand gestures has a classification accuracy of more than 90%.Clinical relevance-The proposed system enables an ultrasound imaging based human machine interface that can be a research and development platform for novel control strategies of a hand prosthesis.


Asunto(s)
Miembros Artificiales , Robótica , Humanos , Brazo/diagnóstico por imagen , Electromiografía/métodos , Extremidad Superior
9.
J Clin Ultrasound ; 51(9): 1512-1521, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37787651

RESUMEN

PURPOSE: Studies examining mortality in palliative care units are limited. We aimed to investigate the mortality and associated factors including ultrasonographic muscle parameters in hospitalized palliative patients with a subgroup analysis of older patients. METHODS: A prospective-observational study. We recorded the demographics, number of diseases, diagnoses, and the Charlson comorbidity index (CCI), palliative performance scale (PPS), and nutritional risk screening-2002 (NRS-2002) scores. We noted the nutritional parameters and mortality. We measured the subcutaneous fat thickness (SFT), muscle thickness (MT), and cross-sectional area (CSA) of the rectus femoris and biceps brachii using ultrasonography. RESULTS: We enrolled 100 patients (mean age: 73.2 ± 16.4 years, 53%: female). One-month mortality was 42%. The non-survivors had significantly higher malignancy, increased CCI and NRS-2002 scores, lower required energy intake, calorie sufficiency rate, and biceps brachii SFT, MT, and CSA than the survivors. The independent mortality predictors were malignancy and biceps brachii CSA while the PPS score and malignancy were significantly associated with mortality in the older subgroup. CONCLUSION: The malignancy and biceps brachii CSA might have prognostic value in predicting mortality in palliative patients. This was the first study investigating the mortality-associated factors including ultrasonographic muscle measurements of both the lower and upper limbs in a palliative care center.


Asunto(s)
Músculo Esquelético , Neoplasias , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Estudios Prospectivos , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/fisiología , Brazo/diagnóstico por imagen , Ultrasonografía , Neoplasias/diagnóstico por imagen
10.
Ultrasound Med Biol ; 49(1): 398-409, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36266142

RESUMEN

Shear wave elastography is an emerging diagnostic tool used to assess for changes in the stiffness of muscle. Each region of the muscle may have a different stiffness; therefore, the anatomical region should be carefully selected. Machine vendors each have unique methods for calculating the returned stiffness values and, consequently, a high level of agreement in measurement between machines (quantified using the intraclass correlation coefficient [ICC] and Bland-Altman analysis) will allow research findings to be translated to the clinic. This study assessed three locations within the biceps muscle (50% and 75% of the distance between the acromioclavicular joint and antecubital fossa, and superior to distal myotendinous junction [MTJ]) of 32 healthy volunteers with two different machines, the Canon Aplio i600 and SuperSonic Imagine Aixplorer (SSI), to compare the reported shear wave velocities and the variability by coefficient of variation (CV) and ICC. There was no difference in the CV between machines, but a significant difference in the CV at muscle regions, with the 75% location having a 40.2% reduction in CV. The 75% location had the highest ICC values with good posterior mean ICCs of 0.84 on the Canon and 0.83 on the SSI. The 50% and MTJ locations had poor ICC values. The 75% location provided the lowest CV and highest ICC and should be used for future stiffness assessments.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Ultrasonografía/métodos , Brazo/diagnóstico por imagen , Músculo Esquelético/diagnóstico por imagen , Codo , Reproducibilidad de los Resultados
11.
Radiologia (Engl Ed) ; 64(6): 525-532, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36402538

RESUMEN

INTRODUCTION AND OBJECTIVES: Obtaining CCTA images with optimal injection location such as the arm or leg is important to avoid the artifacts caused by the CM. This study compares the computed tomography (CT) numbers and visualization scores of the three-dimensional (3D) images of the lumens of the blood vessels in the arm or leg during cardiac computed tomography angiography (CCTA) in neonatal and infant patients. PATIENTS OR MATERIALS AND METHODS: Between January 2017 and January 2020, 253 consecutive patients were considered for inclusion. We used the estimated propensity scores as a function of the demographic data, including age, body weight, and injection location (right or left side) in the arm (n = 58) and leg (n = 58) of neonatal and infant patients. We compared the mean CT numbers of the pulmonary artery, ascending aorta, and left superior vena cava; contrast-noise ratios (CNR); and visualization scores between the arm and leg as the injection locations. RESULTS: The mean CT numbers during CCTA for the arm and leg were 479.4 and 461.3 HU in the ascending aorta, 464.2 and 448.1 HU in the pulmonary artery, and 232.8 and 220.1 HU in the left superior vena cava, respectively. The mean image noise (SD) and CNR values, respectively, were 38.9 HU and 12.1 for the arm as the injection location and 39.1 HU and 12.3 for the leg as the injection location. The median visualization scores of volume rendering of the 3D images were 3.0 and 3.0 for the arm and leg injection sites, respectively. There were no significant differences in the mean CT numbers of the ascending aorta, pulmonary artery, and left superior vena cava; SD value; CNR; and visualization scores between the arm and leg injection locations. CONCLUSIONS: The CT numbers of the lumen of the blood vessel and visualization scores of the 3D images of the arm and leg injection locations are equal during CCTA in neonatal and infant patients with congenital heart disease.


Asunto(s)
Medios de Contraste , Vena Cava Superior , Humanos , Lactante , Recién Nacido , Brazo/diagnóstico por imagen , Pierna , Tomografía Computarizada por Rayos X/métodos
12.
Comput Math Methods Med ; 2022: 6470576, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35096133

RESUMEN

This study was to explore the application value for central venous stenosis and occlusion in hemodialysis patients under the CT angiography based on intelligent segmentation algorithm, so that patients can survive better. Spiral CT was used to examine upper limb swelling in 62 uremic hemodialysis patients at a speed of 3.8 mL/s. Nonionic iodine contrast agent was injected around the contralateral limb. The total dosage of 90-102 mL, it was scanned by intelligent trigger technology. The trigger scanning threshold was set. The monitoring point was located in the superior vena cava. CT with convolutional neural network intelligent segmentation algorithm was used to process image data. Finally, the quality of life and related biochemical levels of patients before and after hemodialysis were detected. Under the CT angiography of intelligent segmentation algorithm, 77 stenoses were found in 62 uremic patients, including 48 stenoses of the brachial vein and 17 stenoses of the superior vena cava. The correlation coefficient between CT angiography and digital subtraction angiography (DSA) imaging results of intelligent segmentation algorithm was 0.411. Segmentation effect of the algorithm in this study: automatic segmentation accuracy was greater than 79%. After hemodialysis treatment, the scores of physical fitness, pain, social function, and energy status of patients were significantly increased compared with those before treatment, and the levels of albumin, serum phosphorus, and parathyroid hormone were significantly decreased (P < 0.05). In summary, CT angiography with intelligent segmentation algorithm can obtain clear, intuitive, and complete vascular walking images, and better display subclavian vein, brachiocephalic vein, and superior vena cava. It can provide more valuable support for surgical intervention and has certain application value for better survival of hemodialysis patients.


Asunto(s)
Algoritmos , Angiografía por Tomografía Computarizada/métodos , Diálisis Renal , Adulto , Anciano , Angiografía de Substracción Digital/métodos , Angiografía de Substracción Digital/estadística & datos numéricos , Brazo/diagnóstico por imagen , Biología Computacional , Angiografía por Tomografía Computarizada/estadística & datos numéricos , Edema/diagnóstico por imagen , Femenino , Humanos , Imagenología Tridimensional/métodos , Imagenología Tridimensional/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/métodos , Tomografía Computarizada Multidetector/estadística & datos numéricos , Redes Neurales de la Computación , Diálisis Renal/efectos adversos , Trombosis Venosa Profunda de la Extremidad Superior/diagnóstico por imagen , Trombosis Venosa Profunda de la Extremidad Superior/etiología , Uremia/diagnóstico por imagen , Uremia/terapia , Dispositivos de Acceso Vascular/efectos adversos , Vena Cava Superior/diagnóstico por imagen , Adulto Joven
13.
NMR Biomed ; 35(7): e4696, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35052014

RESUMEN

Quantitative magnetic resonance imaging (qMRI) is frequently used to map the disease state and disease progression in the lower extremity muscles of patients with spinal muscular atrophy (SMA). This is in stark contrast to the almost complete lack of data on the upper extremity muscles, which are essential for carrying out daily activities. The aim of this study was therefore to assess the disease state in the upper arm muscles of patients with SMA in comparison with healthy controls by quantitative assessment of fat fraction, diffusion indices, and water T2 relaxation times, and to relate these measures to muscle force. We evaluated 13 patients with SMA and 15 healthy controls with a 3-T MRI protocol consisting of DIXON, diffusion tensor imaging, and T2 sequences. qMRI measures were compared between groups and related to muscle force measured with quantitative myometry. Fat fraction was significantly increased in all upper arm muscles of the patients with SMA compared with healthy controls and correlated negatively with muscle force. Additionally, fat fraction was heterogeneously distributed within the triceps brachii (TB) and brachialis muscle, but not in the biceps brachii muscle. Diffusion indices and water T2 relaxation times were similar between patients with SMA and healthy controls, but we did find a slightly reduced mean diffusivity (MD), λ1, and λ3 in the TB of patients with SMA. Furthermore, MD was positively correlated with muscle force in the TB of patients with SMA. The variation in fat fraction further substantiates the selective vulnerability of muscles. The reduced diffusion tensor imaging indices, along with the positive correlation of MD with muscle force, point to myofiber atrophy. Our results show the feasibility of qMRI to map the disease state in the upper arm muscles of patients with SMA. Longitudinal data in a larger cohort are needed to further explore qMRI to map disease progression and to capture the possible effects of therapeutic interventions.


Asunto(s)
Brazo , Atrofia Muscular Espinal , Brazo/diagnóstico por imagen , Imagen de Difusión Tensora/métodos , Progresión de la Enfermedad , Humanos , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/patología , Atrofia Muscular Espinal/diagnóstico por imagen , Extremidad Superior/diagnóstico por imagen , Agua
14.
Lymphat Res Biol ; 20(1): 39-47, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33761290

RESUMEN

Background: Lymphedema (LE) is a significant clinical problem for breast cancer survivors. While the water displacement test and circumferential assessment using a tape measure (TM) are common methods to assess differences in arm volumes, faster and more reliable methods are needed. Study purposes, in breast cancer survivors (n = 294), were to compare the average total arm volumes and interlimb volume ratios for women with and without a history of LE, using a TM and three-dimensional (3D), whole-body surface scanner (3D scan); compare the level of agreement between arm volumes and interlimb volume ratios obtained using the two devices; and evaluate the percent agreement between the two measures in classifying cases of LE using three accepted thresholds. Methods and Results: Measurements were done using a spring-loaded TM and Fit3D ProScanner. Paired t-tests and Bland-Altman analyses were used to achieve the study aims. For circumference and volume comparisons, compared with the 3D scan, values obtained using the TM were consistently smaller. In terms of level of agreement, the Bland-Altman analyses demonstrated large biases and wide limits of agreement for the calculated arm volumes and volume ratios. In terms of the classification of caseness, using the 200-mL interlimb volume difference criterion resulted in 81.6% overall agreement; using the >10% volume difference between the affected and unaffected arms resulted in 78.5% overall agreement; and using the volume ratio ≥1.04 criterion resulted in 62.5% overall agreement. For all three accepted threshold criteria, the percentage of cases was significantly different between the TM and 3D scan techniques. Conclusions: The 3D technology evaluated in this study has the potential to be used for self-initiated surveillance for LE. With improvements in landmark identification and software modifications, it is possible that accurate and reliable total arm volumes can be calculated and used for early detection.


Asunto(s)
Linfedema del Cáncer de Mama , Neoplasias de la Mama , Supervivientes de Cáncer , Linfedema , Brazo/diagnóstico por imagen , Linfedema del Cáncer de Mama/diagnóstico por imagen , Linfedema del Cáncer de Mama/etiología , Neoplasias de la Mama/complicaciones , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Linfedema/diagnóstico por imagen , Linfedema/etiología
15.
J Ultrasound Med ; 41(2): 355-364, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33830545

RESUMEN

OBJECTIVES: Semiautomatic fractional limb volume (FLV) models have recently produced promising results for fetal birth weight (BW) estimation. We tested those models in a more unselected population hypothesizing that the FLV models would improve accuracy and precision of fetal BW estimation compared to the Hadlock model. METHODS: We compared the performance of different BW prediction models: Hadlock (biparietal diameter [BPD], abdominal circumference (AC), femur diaphysis length) and modified Lee thigh volume (TVol) and arm volume (AVol) (BPD, AC, automated fractional TVol, and AVol). Accuracy (systematic errors, mean percent differences) and precision (random errors, ± 1 SD of percent differences) were calculated. RESULTS: A total of 75 fetuses were included for final analysis. The Hadlock model showed the most consistent results with accurate BW estimation not significantly different from zero (-0.37 ± 8.53%). The modified fractional thigh and arm volume models were less accurate but trended toward more precise results (-2.63 ± 7.69% and -3.85 ± 7.47%, respectively). In addition, the modified TVol model showed the trend to predict more BWs within ±10% of the actual BW compared to the Hadlock model (81.3 versus 74.67%, ns). CONCLUSIONS: Based on our results, fetal weight estimation using the modified semiautomatic FLV models generates less accurate results in third-trimester fetuses compared to the Hadlock model. Those models recently published might improve the results of BW prediction by showing a higher precision than conventional models, especially in small and large fetuses. Further studies are needed to investigate the clinical usefulness of the new models.


Asunto(s)
Peso Fetal , Ultrasonografía Prenatal , Brazo/diagnóstico por imagen , Peso al Nacer , Femenino , Edad Gestacional , Humanos , Embarazo , Estudios Prospectivos
16.
J Neurol ; 269(5): 2619-2626, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34676447

RESUMEN

BACKGROUND: Flail arm syndrome is a restricted phenotype of motor neuron disease that is characterized by progressive, predominantly proximal weakness and atrophy of the upper limbs. OBJECTIVE: The study was designed to investigate specific white matter alterations in diffusion tensor imaging (DTI) data from flail arm syndrome patients using a hypothesis-guided tract-of-interest-based approach to identify in vivo microstructural changes according to a neuropathologically defined amyotrophic lateral sclerosis (ALS)-related pathology of the cortico-efferent tracts. METHODS: DTI-based white matter mapping was performed both by an unbiased voxel-wise statistical comparison and by a hypothesis-guided tract-wise analysis of fractional anisotropy (FA) maps according to the neuropathological ALS-propagation pattern for 43 flail arm syndrome patients vs 43 'classical' ALS patients vs 40 matched controls. RESULTS: The analysis of white matter integrity demonstrated regional FA reductions for the flail arm syndrome group predominantly along the CST. In the tract-specific analysis according to the proposed sequential cerebral pathology pattern of ALS, the flail arm syndrome patients showed significant alterations of the specific tract systems that were identical to 'classical' ALS if compared to controls. CONCLUSIONS: The DTI study including the tract-of-interest-based analysis showed a microstructural involvement pattern in the brains of flail arm syndrome patients, supporting the hypothesis that flail arm syndrome is a phenotypical variant of ALS.


Asunto(s)
Esclerosis Amiotrófica Lateral , Enfermedades Vasculares , Esclerosis Amiotrófica Lateral/complicaciones , Esclerosis Amiotrófica Lateral/diagnóstico por imagen , Esclerosis Amiotrófica Lateral/patología , Anisotropía , Brazo/diagnóstico por imagen , Brazo/patología , Mapeo Encefálico , Imagen de Difusión Tensora/métodos , Progresión de la Enfermedad , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Tractos Piramidales
17.
Dermatol Online J ; 27(8)2021 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-34755959

RESUMEN

Eosinophilic fasciitis (EF) and generalized morphea (GM) are rare and difficult-to-treat sclerosing skin diseases which may occur in association with hematologic disorders. We present a 66-year-old man with EF and associated Waldenström macroglobulinemia who received combination therapy with rituximab (375mg/m2 every other week, gradually extended to every eight weeks), prednisolone (1.25-30mg/d), and methotrexate (7.5-15mg/w). Three months after rituximab initiation, his skin condition improved steadily accompanied by a significant improvement in joint mobility with only mild and transitory flares (observation period: 59 months under treatment with rituximab). To date, there are five case reports on rituximab treatment of EF/GM with an association to hypergammaglobulinemia in three of those cases. Therapy effected significant improvement in four patients. Our case adds to the hitherto limited evidence that rituximab may be a promising therapeutic strategy for EF/GM in association with hypergammaglobulinemia.


Asunto(s)
Eosinofilia/tratamiento farmacológico , Fascitis/tratamiento farmacológico , Factores Inmunológicos/uso terapéutico , Rituximab/uso terapéutico , Macroglobulinemia de Waldenström/complicaciones , Anciano , Brazo/diagnóstico por imagen , Quimioterapia Combinada , Eosinofilia/complicaciones , Eosinofilia/diagnóstico por imagen , Eosinofilia/patología , Fascitis/complicaciones , Fascitis/diagnóstico por imagen , Fascitis/patología , Glucocorticoides/uso terapéutico , Humanos , Masculino , Metotrexato/uso terapéutico , Prednisolona/uso terapéutico
19.
Parkinsonism Relat Disord ; 91: 96-101, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34547655

RESUMEN

BACKGROUND: The supplementary motor area (SMA) is implicated in stereotypic multi-limb movements such as walking with arm swing. Gait difficulties in Parkinson's Disease (PD) include reduced arm swing, which is associated with reduced SMA activity. OBJECTIVE: To test whether enhanced arm swing improves Parkinsonian gait and explore the role of the SMA in such an improvement. METHODS: Cortical activity and gait characteristics were assessed by ambulant EEG, accelerometers and video recordings in 27 PD patients with self-reported gait difficulties and 35 healthy participants when walking normally. Within these two groups, 19 PD patients additionally walked with enhanced arm swing and 30 healthy participants walked without arm swing. Power changes across the EEG frequency spectrum were assessed by Event Related Spectral Perturbation analysis of recordings from Fz over the putative SMA and gait analysis was performed. RESULTS: Baseline PD gait, characterized by reduced arm swing among other features, exhibited reduced within-step Event Related Desynchronization (ERD)/Synchronization (ERS) alternation (Fz; 20-50Hz), accompanied by a reduced step length and walking speed. All became similar to normal gait when patients walked with enhanced arm swing. When healthy controls walked without arm swing, their alternating ERD-ERS pattern decreased, mimicking baseline PD gait. CONCLUSION: Enhanced arm swing may serve as a driving force to overcome impaired gait control in PD patients by restoring reduced ERD-ERS alternation over the putative SMA. Accompanied by increased step length and walking speed, this provides a neural underpinning of arm swing as an effective rehabilitation concept for improving Parkinsonian gait.


Asunto(s)
Electroencefalografía , Trastornos Neurológicos de la Marcha/fisiopatología , Marcha , Enfermedad de Parkinson/fisiopatología , Acelerometría , Anciano , Brazo/diagnóstico por imagen , Brazo/fisiopatología , Estudios de Casos y Controles , Femenino , Análisis de la Marcha , Trastornos Neurológicos de la Marcha/diagnóstico por imagen , Trastornos Neurológicos de la Marcha/etiología , Humanos , Masculino , Corteza Motora/fisiopatología , Enfermedad de Parkinson/complicaciones , Enfermedad de Parkinson/diagnóstico por imagen , Grabación en Video , Caminata , Velocidad al Caminar
20.
Nutrients ; 13(7)2021 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-34371860

RESUMEN

Identification of low muscle mass becomes increasingly relevant due to its prognostic value in cancer patients. In clinical practice, mid-upper arm muscle circumference (MAMC) and bioelectrical impedance analysis (BIA) are often used to assess muscle mass. For muscle-mass assessment, computed tomography (CT) is considered as reference standard. We investigated concordance between CT, BIA, and MAMC, diagnostic accuracy of MAMC, and BIA to detect low muscle mass and their relation with the clinical outcome malnutrition provided with the Patient-Generated Subjective Global Assessment Short Form (PG-SGA SF). This cross-sectional study included adult patients with advanced esophageal and gastrointestinal cancer. BIA, MAMC, and PG-SGA-SF were performed. Routine CT-scans were used to quantify psoas muscle index (PMI) and skeletal muscle area. Good concordance was found between CTPMI and both BIAFFMI (fat free mass index) (ICC 0.73), and BIAASMI (appendicular skeletal muscle index) (ICC 0.69) but not with MAMC (ICC 0.37). BIAFFMI (94%), BIAASMI (86%), and MAMC (86%) showed high specificity but low sensitivity. PG-SGA-SF modestly correlated with all muscle-mass measures (ranging from -0.17 to -0.43). Of all patients with low muscle mass, 62% were also classified with a PG-SGA-SF score of ≥4 points. Although CT remains the first choice, since both BIA and MAMC are easy to perform by dieticians, they have the potential to be used to detect low muscle mass in clinical practice.


Asunto(s)
Antropometría/métodos , Impedancia Eléctrica , Músculo Esquelético/fisiopatología , Evaluación Nutricional , Sarcopenia/diagnóstico , Anciano , Brazo/diagnóstico por imagen , Brazo/fisiopatología , Índice de Masa Corporal , Estudios Transversales , Neoplasias Esofágicas/complicaciones , Neoplasias Esofágicas/fisiopatología , Femenino , Neoplasias Gastrointestinales/complicaciones , Neoplasias Gastrointestinales/fisiopatología , Humanos , Masculino , Desnutrición/complicaciones , Desnutrición/fisiopatología , Persona de Mediana Edad , Músculo Esquelético/diagnóstico por imagen , Estado Nutricional , Estudios Prospectivos , Reproducibilidad de los Resultados , Sarcopenia/etiología , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS