Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.458
Filtrar
1.
J Refract Surg ; 40(7): e453-e459, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39007816

RESUMEN

PURPOSE: To compare the prediction accuracy of the Barrett toric calculator using standard or integrated keratometry (IK) mode in combination with predicted or measured posterior corneal astigmatism (PCA) in a group of patients with cataract implanted with non-toric IOLs. METHODS: In this retrospective clinical cohort study, the medical records of patients with age-related cataract who underwent phacoemulsification with the implantation of an aspheric monofocal IOL were reviewed. Four methods, including standard keratometry with predicted PCA (PPCA), IK combined with predicted PCA (IK-PPCA), and IK combined with measured PCA derived from IOLMaster 700 (Carl Zeiss Meditec AG) or CASIA2 (Tomey) (IK-MMPCA or IK-CMPCA), were applied to the Barrett toric calculator to calculate the predicted residual astigmatism. The mean absolute prediction error (MAPE), centroid of the prediction error, and proportion of eyes within the prediction error of ±0.50, ±0.75, and ±1.00 diopters (D) were all ciphered out from the four methods, respectively. RESULTS: Data from 129 eyes of 129 patients were included in this study. The MAPE of the IK-PPCA method (0.57 ± 0.36 D) was significantly smaller than that of the PPCA (0.62 ± 0.38 D) and IK-CMPCA (0.63 ± 0.46 D) methods (P = .048 and .014, respectively). There were no significant differences in the centroid vectors of prediction errors and predictability rates among the four methods (all P > .05). CONCLUSIONS: In the current version of the Barrett toric calculator, the predictive accuracy of the IK mode incorporating PPCA was slightly superior to using the standard keratometry mode or incorporating MPCA. [J Refract Surg. 2024;40(7):e453-e459.].


Asunto(s)
Astigmatismo , Córnea , Facoemulsificación , Humanos , Astigmatismo/fisiopatología , Astigmatismo/diagnóstico , Estudios Retrospectivos , Masculino , Femenino , Anciano , Córnea/fisiopatología , Córnea/patología , Reproducibilidad de los Resultados , Persona de Mediana Edad , Anciano de 80 o más Años , Implantación de Lentes Intraoculares , Agudeza Visual/fisiología , Topografía de la Córnea/métodos , Refracción Ocular/fisiología , Lentes Intraoculares , Seudofaquia/fisiopatología
2.
J Refract Surg ; 40(7): e480-e489, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39007817

RESUMEN

PURPOSE: To evaluate the effectiveness, safety, and stability of a modified PRESBYOND Laser Blended Vision protocol (Carl Zeiss Meditec AG) for correcting hyperopic astigmatism and presbyopia, using Custom Refractive Software Master (CRSM) targeting over a 6-month period. METHODS: A total of 636 eyes of 318 patients with a mean age of 51.05 ± 4.71 years (range: 40 to 60 years) met the inclusion and exclusion criteria. All patients completed a 6-month follow-up. CRSM software was used to generate ablation profiles for the MEL90 excimer laser (Carl Zeiss Meditec AG). The target refraction was emmetropic for the dominant eyes and between -0.75 and -1.12 diopters (D) for the near eyes. RESULTS: Visual and refractive results were studied separately by the dominant and non-dominant eyes. The mean attempt to correct for spherical equivalent refraction was +2.17 ± 1.16 D (range: -1.00 to +5.37 D). The mean attempted cylinder was -0.60 ± 0.75 D (range: -4.00 to 0.00 D). All eyes monocularly achieved uncorrected distance visual acuity (UDVA) of 20/25 or better after refractive treatment and 88% achieved 20/20. Binocularly all eyes achieved UDVA of 20/25 or better and 96.54% achieved 20/20. Ninety-eight percent of the patients maintained their corrected distance visual acuity before surgery and UDVA 6 months after surgery. CONCLUSIONS: This hyperopic micro-anisometropia protocol with PRESBYOND Laser Blended Vision was an effective, safe, and well-tolerated refractive treatment. It was an effective procedure with excellent results for UDVA and uncorrected near visual acuity and demonstrates that binocular summation exists. [ J Refract Surg. 2024;40(7):e480-e489.].


Asunto(s)
Astigmatismo , Hiperopía , Queratomileusis por Láser In Situ , Láseres de Excímeros , Presbiopía , Refracción Ocular , Programas Informáticos , Agudeza Visual , Humanos , Presbiopía/cirugía , Presbiopía/fisiopatología , Queratomileusis por Láser In Situ/métodos , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Láseres de Excímeros/uso terapéutico , Masculino , Hiperopía/fisiopatología , Hiperopía/cirugía , Persona de Mediana Edad , Femenino , Adulto , Astigmatismo/fisiopatología , Astigmatismo/cirugía , Resultado del Tratamiento , Anisometropía/fisiopatología , Anisometropía/cirugía , Topografía de la Córnea , Estudios de Seguimiento , Estudios Prospectivos , Córnea/fisiopatología , Córnea/cirugía
3.
Int Ophthalmol ; 44(1): 302, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38954134

RESUMEN

PURPOSE: To compare early changes in the corneal biomechanical parameters after photorefractive keratectomy (PRK) and small incision lenticule extraction (SMILE) and their correlations with corneal shape parameters. METHODS: One hundred twenty four eyes received myopic PRK and SMILE for similar amounts of myopia. Corneal tomography with Pentacam HR, biomechanical parameters using Corvis ST, and Ocular Response Analyzer (ORA) were evaluated before and 2 weeks after surgery. The change in each parameter was compared between groups, while the difference in central corneal thickness and cornea-compensated intraocular pressure measured before and after surgery were considered as covariates. RESULTS: A significant reduction was seen in the corneal stiffness parameter at first applanation, and an increase in deformation amplitude ratio (DAR), and integrated inverse radius (IIR) in both groups after surgery (p < 0.001) Changes in DAR, and IIR were significantly greater in the SMILE than in the PRK group (p < 0.001) Corneal hysteresis (CH) and corneal resistance factor (CRF) decreased in both SMILE and PRK groups after surgery, (p < 0.001) with no statistically significant difference between groups (p > 0.05) Among new Corvis ST parameters, DAR showed a significant correlation with changes in Ambrosio relational thickness in both groups (p < 0.05). CONCLUSIONS: Both techniques caused significant changes in corneal biomechanics in the early postoperative period, with greater elastic changes in the SMILE group compared to the PRK group, likely due to lower tension in the SMILE cap and thinner residual stromal bed in SMILE. There were no differences in viscoelastic changes between them, so the lower CH may reflect the volume of tissue removed.


Asunto(s)
Córnea , Elasticidad , Miopía , Queratectomía Fotorrefractiva , Humanos , Queratectomía Fotorrefractiva/métodos , Miopía/cirugía , Miopía/fisiopatología , Córnea/cirugía , Córnea/fisiopatología , Córnea/diagnóstico por imagen , Femenino , Masculino , Adulto , Elasticidad/fisiología , Fenómenos Biomecánicos , Adulto Joven , Láseres de Excímeros/uso terapéutico , Presión Intraocular/fisiología , Cirugía Laser de Córnea/métodos , Refracción Ocular/fisiología , Topografía de la Córnea , Sustancia Propia/cirugía , Periodo Posoperatorio , Agudeza Visual/fisiología , Estudios Prospectivos , Estudios de Seguimiento
4.
Int Ophthalmol ; 44(1): 300, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38951418

RESUMEN

PURPOSE: To assess the accuracy of a prototype novel instrument for intra ocular pressure (IOP) measurements not involving corneal pressure application. DESIGN: Prospective case control study. METHODS: An institutional study including 16 healthy volunteers without ocular pathology. IOP in both eyes of the participants was measured four times in different body positions with the novel prototype and reference instrument (Goldmann applanation tonometer (GAT) or iCare (iCare Finland OY, Vantaa, Finland)). IOP results were compared between the prototype and the reference instruments in 116 pairs of measurement. RESULTS: Overall no statistically significant difference was found between the presented prototype and the reference instrument. Stratifying measurements by instrument used revealed no significant difference for GAT and statistical significant (yet clinically insignificant) difference for iCare. CONCLUSIONS: The presented prototype demonstrates good clinical agreement of IOP measuring results with reference instruments Further large-scale studies assessing this instrument in glaucoma patients are warranted.


Asunto(s)
Córnea , Presión Intraocular , Tonometría Ocular , Humanos , Presión Intraocular/fisiología , Estudios Prospectivos , Tonometría Ocular/instrumentación , Tonometría Ocular/métodos , Femenino , Masculino , Adulto , Córnea/fisiopatología , Reproducibilidad de los Resultados , Estudios de Casos y Controles , Persona de Mediana Edad , Adulto Joven , Voluntarios Sanos , Glaucoma/diagnóstico , Glaucoma/fisiopatología , Diseño de Equipo
5.
Lasers Med Sci ; 39(1): 178, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38990392

RESUMEN

To evaluate the visual outcome and astigmatic correction following trifocal intraocular lens (IOL) implantation using the modified femtosecond laser-assisted arcuate keratotomy (FSAK) in Chinese cataract patients with low astigmatism. This retrospective study included consecutive cataract patients with regular corneal astigmatism ranging from 0.75 to 1.5 D who underwent FSAK combined with the trifocal IOL implantation between November 2020 and September 2022. Monocular uncorrected distance visual acuity, uncorrected intermediate visual acuity, uncorrected near visual acuity, and refractive data were collected at the 3-month follow-up. The pre- and post-operative high-order aberrations (HOAs) were recorded. The variation in astigmatism was analyzed using Alpins vector analysis. A total of 27 eyes from 23 patients were analyzed. The monocular uncorrected distance visual acuity (UDVA) (5 m) at the 3-month follow-up was 0.04 ± 0.09 logarithm of the minimum angle of resolution (logMAR), which was significantly improved compared with the preoperative value of 0.95 ± 0.51 logMAR (P <.001). The corneal astigmatism was significantly reduced from 1.24 ± 0.42 D to 0.49 ± 0.34 D (P <.001). The target-induced astigmatism (TIA) was 1.25 ± 0.43 D, the surgically induced astigmatism (SIA) was 1.16 ± 0.52 D, and the difference vector (DV) was 0.5 ± 0.34 D. The magnitude of error (ME) (difference between SIA and TIA) was -0.1 ± 0.41 D, and the correction index (CI) (ratio of SIA to TIA) was 0.93 ± 0.36. The angle of error was 3.92° ± 16.90°. Total HOA was reduced from 0.89 ± 1.11 to 0.41 ± 0.55 (P = 0.184), and the corneal HOA was lowered from 0.17 ± 0.18 to 0.10 ± 0.10 (P = 0.129). Implantation of trifocal IOL following the modified FSAK in Chinese cataract patients exhibited excellent visual efficacy and effectively reduced corneal astigmatism.


Asunto(s)
Astigmatismo , Catarata , Agudeza Visual , Humanos , Astigmatismo/cirugía , Astigmatismo/fisiopatología , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Catarata/complicaciones , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares Multifocales , Adulto , China , Córnea/cirugía , Córnea/fisiopatología , Resultado del Tratamiento , Pueblos del Este de Asia
6.
Cesk Slov Oftalmol ; 80(Ahead of print): 1-12, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38925892

RESUMEN

AIMS: To investigate the concordance between the corneal power determined by various approaches with two tomographers (MS-39® and Galilei G6®) and the clinical history method (CHM) in patients undergoing photorefractive surgery with excimer laser for myopic errors. MATERIAL AND METHODS: Prospective cohort study. Patients undergoing keratorefractive surgery, and having pre- and postoperative keratometries, and tomographies, were included. RESULTS: In 90 eyes, the differences in the power estimated by the CHM and the one determined by four approaches with the corneal tomographers, which included measurements of the posterior cornea, did not show statistically significant differences in their averages. However, the 95% limits of agreement were very wide. After obtaining regression formulas to adjust the values of these four variables, the results of the agreement analysis were similar. CONCLUSION: Although certain values either directly determined or derived from measurements with the Galilei® and MS-39®corneal tomographers, approximated the estimated value of postoperative corneal power according to the CHM, due to the amplitude of their limits of agreement, these calculations must be taken with care, because they may not be accurate in a given eye.


Asunto(s)
Córnea , Miopía , Humanos , Córnea/diagnóstico por imagen , Córnea/cirugía , Córnea/patología , Córnea/fisiopatología , Miopía/cirugía , Miopía/fisiopatología , Miopía/diagnóstico por imagen , Adulto , Estudios Prospectivos , Masculino , Femenino , Queratectomía Fotorrefractiva , Adulto Joven , Topografía de la Córnea , Láseres de Excímeros/uso terapéutico , Refracción Ocular
7.
Invest Ophthalmol Vis Sci ; 65(6): 15, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38848076

RESUMEN

Purpose: The purpose of this study was to investigate the associations between visual function and severity grading, corneal scatter, or higher-order aberrations (HOAs) in patients with Fuchs endothelial corneal dystrophy (FECD). Methods: This observational case series study included 49 eyes of 27 patients with FECD and 10 eyes of 10 healthy individuals. We evaluated corrected distance visual acuity (CDVA) using Landolt-C and Early Treatment Diabetic Retinopathy Study charts and contrast sensitivity using the CSV-1000E chart and CSV-1000RN letter chart. We analyzed the associations between visual function and explanatory variables, including age, modified Krachmer grade, central corneal thickness (CCT), anterior segment optical coherence tomography (AS-OCT)-based grade, HOAs, intraocular straylight, and corneal densitometry. We additionally conducted receiver operating characteristic (ROC) analysis to identify the corneal densitometry thresholds for decreased visual function. Results: There were significant associations between visual function and the modified Krachmer grade, CCT, AS-OCT-based grade, HOAs, intraocular straylight, and corneal densitometry. A modified Krachmer grade ≥ 3 was identified as a threshold for decreased visual function. Multivariate analysis showed that corneal densitometry was significantly associated with all visual function parameters, and HOAs were significantly associated with CDVA but not with contrast sensitivity. ROC analysis revealed that corneal densitometry of the posterior layer at 0 to 2 mm ≥ 10 grayscale units (GSU), was identified as a threshold for decreased visual function. Conclusions: HOAs, forward and backward light scatter affected visual function, with backward light scatter being the most influential. In patients with FECD, modified Krachmer grade ≥ 3 and corneal densitometry ≥ 10 GSU were thresholds for visual disturbance.


Asunto(s)
Sensibilidad de Contraste , Aberración de Frente de Onda Corneal , Distrofia Endotelial de Fuchs , Dispersión de Radiación , Agudeza Visual , Humanos , Distrofia Endotelial de Fuchs/fisiopatología , Distrofia Endotelial de Fuchs/diagnóstico , Femenino , Masculino , Agudeza Visual/fisiología , Persona de Mediana Edad , Anciano , Sensibilidad de Contraste/fisiología , Aberración de Frente de Onda Corneal/fisiopatología , Aberración de Frente de Onda Corneal/diagnóstico , Tomografía de Coherencia Óptica/métodos , Córnea/fisiopatología , Córnea/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Curva ROC , Anciano de 80 o más Años , Adulto
8.
J Refract Surg ; 40(6): e420-e434, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38848055

RESUMEN

PURPOSE: To discuss factors influencing corneal aberrations that might influence the optical quality after intraocular lens (IOL) implantation. METHODS: PubMed and Scopus were the main resources used to search the medical literature. An extensive search was performed to identify relevant articles concerning factors influencing the level of corneal aberrations as of August 27, 2023. The following keywords were used in various combinations: corneal, aberrations, defocus, astigmatism, spherical aberration, coma, trefoil, quadrafoil, intraocular lens, and IOL. RESULTS: Conclusive evidence is lacking regarding the correlation between age and changes in corneal aberrations. Patients with astigmatism have greater corneal higher-order aberrations than those with minimal astigmatism, particularly concerning trefoil and coma. Increased levels of corneal higher-order aberrations are noted following contact lens wear, in patients with dry eye disease, and with pterygium. Increased higher-order aberrations have been reported following corneal refractive surgery and for 3 months following trabeculectomy; regarding intraocular lens surgery, the results remain controversial. CONCLUSIONS: Several factors influence the level of corneal higher-order aberrations. Multifocal and extended depth-of-focus IOLs can share similarities in their optical properties, and the main difference arises in their design and performance with respect to spherical aberration. Preoperative evaluation is critical for proper IOL choice, particularly in corneas with risk of high levels of aberrations. [J Refract Surg. 2024;40(6):e420-e434.].


Asunto(s)
Aberración de Frente de Onda Corneal , Implantación de Lentes Intraoculares , Refracción Ocular , Agudeza Visual , Humanos , Aberración de Frente de Onda Corneal/fisiopatología , Aberración de Frente de Onda Corneal/etiología , Factores de Riesgo , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Lentes Intraoculares Multifocales , Percepción de Profundidad/fisiología , Topografía de la Córnea , Córnea/fisiopatología
10.
J Refract Surg ; 40(6): e354-e361, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38848053

RESUMEN

PURPOSE: To assess the predictive accuracy of new-generation online intraocular lens (IOL) power formulas in eyes with previous myopic laser refractive surgery (LRS) and to evaluate the influence of corneal asphericity on the predictive accuracy. METHODS: The authors retrospectively evaluated 52 patients (78 eyes) with a history of laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) who subsequently underwent cataract surgery. Refractive prediction errors were calculated for 12 no-history new online formulas: 8 formulas with post-LRS versions (Barrett True-K, EVO 2.0, Hoffer QST, and Pearl DGS) using keratometry and posterior/total keratometry measured by IOLMaster 700 and 4 formulas without post-LRS versions (Cooke K6 and Kane) using keratometry and total keratometry. The refractive prediction error, mean absolute error (MAE), and percentages of eyes with prediction errors of ±0.25, ±0.50, ±0.75, ±1.00, and ±1.50 diopters (D) were compared. RESULTS: The MAEs of the 12 formulas were significantly different (F = 83.66, P < .001). The MAEs ranged from 0.62 to 0.94 D and from 1.07 to 1.84 D in the formulas with and without post-LRS versions, respectively. The EVO formula produced the lowest MAE (0.60) and MedAE (0.47), followed by the Barrett True-K (0.69 and 0.50, respectively). Each percentage of eyes with refractive prediction error was also significantly different among the 12 formulas (P < .001). CONCLUSIONS: The EVO and Barrett True-K formulas demonstrate comparable performance to the other existing formulas in eyes with a history of myopic LASIK/PRK. Surgeons should use these formulas with post-LRS versions and input keratometric values whenever possible. [J Refract Surg. 2024;40(6):e354-e361.].


Asunto(s)
Queratomileusis por Láser In Situ , Implantación de Lentes Intraoculares , Lentes Intraoculares , Miopía , Óptica y Fotónica , Queratectomía Fotorrefractiva , Refracción Ocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Miopía/cirugía , Miopía/fisiopatología , Femenino , Masculino , Refracción Ocular/fisiología , Persona de Mediana Edad , Queratectomía Fotorrefractiva/métodos , Queratomileusis por Láser In Situ/métodos , Adulto , Agudeza Visual/fisiología , Láseres de Excímeros/uso terapéutico , Córnea/cirugía , Córnea/fisiopatología , Reproducibilidad de los Resultados , Biometría/métodos , Facoemulsificación , Anciano
12.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717086

RESUMEN

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Asunto(s)
Córnea , Elasticidad , Presión Intraocular , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Humanos , Córnea/fisiopatología , Córnea/cirugía , Adulto , Femenino , Masculino , Fenómenos Biomecánicos , Láseres de Excímeros/uso terapéutico , Queratomileusis por Láser In Situ/métodos , Adulto Joven , Elasticidad/fisiología , Miopía/cirugía , Miopía/fisiopatología , Presión Intraocular/fisiología , Queratectomía Fotorrefractiva/métodos , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Persona de Mediana Edad , Estudios Prospectivos , Cirugía Laser de Córnea/métodos , Topografía de la Córnea
13.
Vestn Oftalmol ; 140(2. Vyp. 2): 51-59, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38739131

RESUMEN

PURPOSE: The study investigates the influence of changes in keratometric parameters after refractive surgery on the results of Maklakov tonometry. MATERIAL AND METHODS: The study examined a total of 61 people (121 eyes). The patients were divided into a control group with no history of surgery (16 people, 31 eyes), a LASIK group (13 people, 26 eyes), a femtosecond-assisted LASIK (FS-LASIK) group (16 people, 32 eyes), and a photorefractive keratectomy (PRK) group (16 people, 32 eyes). The patients underwent standard examination, keratometry (Km), Maklakov tonometry with a 10 g weight, and elastotonometry with 5, 7.5, and 15 g weights. RESULTS: In the LASIK group, the indentation diameter with 5 and 7.5 g weights correlated with Km in the central and near-paracentral zone (r=0.3-0.5). Tonometry with a 10 g weight did not correlate with anything. Tonometry with a 15 g weight inversely correlated with Km in the paracentral points (4 mm) of the strong meridian (r= -0.5 ... -0.7). In the FS-LASIK group, a significant inverse correlation with Km was observed only for the indentation diameter with a 10 g weight in the paracentral (3-4 mm) zone (r= -0.4 ... -0.5). In the PRK group, weak (r<0.4) correlations were found between Km and the indentation diameter of the 7.5 and 10 g weights for the central zone (1-2 mm). No significant correlations were found for 5 and 15 g weights.In the control group, there were practically no correlations for 5 and 7.5 g weights. The indentation diameter of the 10 g weight evenly correlated with Km at all points (r= -0.38 ... -0.60), the indentation of the 15 g weight correlated mainly with the curvature of the horizontal meridian (r= -0.37 ... -0.49). CONCLUSION: Tonometry readings with the 10 g weight are the most dependent on Km in different groups, and the readings with the 5 g weight are the least dependent. LASIK is characterized by the largest scatter of dependencies for weights of different masses, FS-LASIK - by the smallest. Tonometry readings with the 5 g weight correlated with Km only in the LASIK group, and this was the only direct correlation. Considering the inverse nature of most correlations, higher Km may be associated with an overestimation of tonometry results, and lower Km - with its underestimation.


Asunto(s)
Queratomileusis por Láser In Situ , Queratectomía Fotorrefractiva , Tonometría Ocular , Humanos , Adulto , Masculino , Femenino , Tonometría Ocular/métodos , Queratectomía Fotorrefractiva/métodos , Queratomileusis por Láser In Situ/métodos , Córnea/cirugía , Córnea/diagnóstico por imagen , Córnea/fisiopatología , Miopía/cirugía , Miopía/fisiopatología , Miopía/diagnóstico , Presión Intraocular/fisiología
14.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717083

RESUMEN

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Asunto(s)
Aberrometría , Astigmatismo , Córnea , Sustancia Propia , Aberración de Frente de Onda Corneal , Densitometría , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Aberración de Frente de Onda Corneal/fisiopatología , Estudios Prospectivos , Miopía/cirugía , Miopía/fisiopatología , Adulto , Femenino , Masculino , Láseres de Excímeros/uso terapéutico , Agudeza Visual/fisiología , Sustancia Propia/cirugía , Córnea/cirugía , Córnea/fisiopatología , Adulto Joven , Refracción Ocular/fisiología , Astigmatismo/cirugía , Astigmatismo/fisiopatología , Cirugía Laser de Córnea/métodos , Topografía de la Córnea
15.
J Refract Surg ; 40(5): e336-e343, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717081

RESUMEN

PURPOSE: To assess and compare the visual acuity and refractive outcomes of topography-guided laser in situ keratomileusis (LASIK) based on the fitting-shape-based refractive compensated and Phorcides software strategies. METHODS: Consecutive patients who underwent topography-guided LASIK were included in this study. Through double-masked simple randomization, patients were assigned to the Zhang & Zheng Auto-compensate Refraction (ZZ AR) group (the fitting-shape-based refractive compensated strategy using the ZZ AR calculator was used) or the Phorcides group (the topography analysis algorithm in Phorcides software [Phorcides LLC] was used). Only one eye per patient with binocular correction was randomly enrolled. The preoperative and postoperative visual acuities and refraction were analyzed at the 6-month follow-up visit. RESULTS: The ZZ AR and Phorcides groups comprised 156 and 147 eyes, respectively. At the 6-month postoperative follow-up visit, the median (range) absolute residual cylindrical refraction was 0.35 (1.01) and 0.47 (1.63) diopters (D) for the ZZ AR and Phorcides groups, respectively (P < .001). The percentages of patients with residual cylindrical power within 0.25 D were 29.49% and 13.61% for the ZZ AR and Phorcides groups, respectively (P = .001). Based on the percentages of patients with residual cylindrical powers within 0.50 and 1.00 D, the ZZ AR group showed better outcomes (P = .02 and .01). The percentage of patients with visual acuity better than 20/16 was significantly higher for the ZZ AR group than for the Phorcides group (P = .03). CONCLUSIONS: The fitting-shape-based refractive compensated strategy for topography-guided LASIK procedures can better optimize the visual acuity and astigmatic refraction than the Phorcides software strategy. [J Refract Surg. 2024;40(5):e336-e343.].


Asunto(s)
Topografía de la Córnea , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Refracción Ocular , Cirugía Asistida por Computador , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Agudeza Visual/fisiología , Estudios Prospectivos , Refracción Ocular/fisiología , Adulto , Masculino , Femenino , Láseres de Excímeros/uso terapéutico , Método Doble Ciego , Miopía/cirugía , Miopía/fisiopatología , Adulto Joven , Cirugía Asistida por Computador/métodos , Persona de Mediana Edad , Córnea/cirugía , Córnea/fisiopatología , Estudios de Seguimiento
16.
J Biomech ; 169: 112145, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38761745

RESUMEN

To investigate the optimal cutting depth (Cap) in small incision lenticule extraction from the perspective of corneal biomechanics, a three-dimensional finite element model of the cornea was established using a stromal sub-regional material model to simulate small incision lenticule extraction. The displacement difference PΔ at the central point of the posterior corneal surface before and after lenticule extraction, as well as the von Mises stress at four points of different thicknesses in the center of the cornea, were analyzed using the finite element model considering the hyperelastic property and the difference in stiffness between the anterior and posterior of the cornea. The numerical curves of PΔ-Cap and von Mises Stress-Cap relations at different diopters show that the displacement difference PΔ has a smallest value at the same diopter. In this case, the von Mises stress at four points with different thicknesses in the center of the cornea was also minimal. Which means that the optimal cutting depth exsisting in the cornea. Moreover, PΔ-Cap curves for different depth of stromal stiffness boundaries show that the optimal cap thickness would change with the depth of the stromal stiffness boundary. These results are of guiding significance for accurately formulating small incision lenticule extraction surgery plans and contribute to the advancement of research on the biomechanical properties of the cornea.


Asunto(s)
Córnea , Análisis de Elementos Finitos , Modelos Biológicos , Humanos , Córnea/cirugía , Córnea/fisiología , Córnea/fisiopatología , Fenómenos Biomecánicos , Sustancia Propia/cirugía , Estrés Mecánico , Cirugía Laser de Córnea/métodos , Simulación por Computador
17.
Indian J Ophthalmol ; 72(5): 712-717, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648433

RESUMEN

PURPOSE: To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and iso-osmolar riboflavin in corneal thicknesses of <400 and >400 microns, respectively. METHODS: This is a prospective, interventional, comparative study involving 100 eyes of 75 patients with progressive keratoconus. Eyes were divided into two groups based on corneal thickness: group 1 included eyes with a corneal thickness of <400 microns who underwent hypo-osmolar CXL, and group 2 included eyes with a corneal thickness of >400 microns who underwent iso-osmolar CXL. Corneal biomechanical and aberration profiles were evaluated and compared between groups. RESULTS: In group 1, all higher-order aberrations (HOA) except secondary astigmatism significantly decreased from baseline; however, in group 2, only coma and trefoil decreased. The corneal resistance factor and corneal hysteresis significantly improved in both groups, which was significantly greater in group 2 than in group 1. The change in inverse radius, deformation amplitude, and tomographic biomechanical index was significantly improved in group 2 as compared to group 1. CONCLUSION: Improvement in corrected distance visual acuity and decrease in HOA were significantly better in the hypo-osmolar CXL group; however, the improvement in biomechanical strength of the cornea was significantly better in the iso-osmolar group.


Asunto(s)
Colágeno , Córnea , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fármacos Fotosensibilizantes , Riboflavina , Rayos Ultravioleta , Agudeza Visual , Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven , Fenómenos Biomecánicos , Colágeno/metabolismo , Córnea/diagnóstico por imagen , Córnea/fisiopatología , Córnea/efectos de los fármacos , Sustancia Propia/metabolismo , Sustancia Propia/efectos de los fármacos , Aberración de Frente de Onda Corneal/fisiopatología , Reactivos de Enlaces Cruzados/uso terapéutico , Estudios de Seguimiento , Queratocono/tratamiento farmacológico , Queratocono/fisiopatología , Queratocono/diagnóstico , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Refracción Ocular/fisiología , Riboflavina/uso terapéutico , Agudeza Visual/fisiología , Niño
18.
Curr Eye Res ; 49(7): 768-775, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38616539

RESUMEN

PURPOSE: This study aims to elucidate the longitudinal refractive and ocular biometric alterations in preschool children with high hyperopia who underwent early interventions. METHODS: We conducted a retrospective analysis of preschool children diagnosed with high hyperopia at Tianjin Medical University Eye Hospital between 2011 and 2023. Inclusion criteria required an initial examination with cycloplegic refraction, bilateral spherical equivalent power (SE) ≥ +5.00D with a difference <1.00D, a minimum two-year follow-up, and at least three ocular biometric measurements. The annual axial growth rate evaluated emmetropization in highly hyperopic children. We applied Restricted Cubic Spline (RCS) models to explore potential nonlinear relationships between age and spherical equivalent, axial length, corneal curvature, and axial length-to-corneal curvature ratio. Additionally, Mixed-effects models were employed to investigate factors associated with changes in refractive error and axial length. RESULTS: The study enrolled 60 eligible subjects, with a median initial diagnosis age of 3.5 years (IQR, 2.8-4.9 years) and a median last visit age of 9.3 years (IQR, 8.1-10.8 years). The average follow-up duration was 5.7 years. RCS analysis revealed notable nonlinear changes in spherical equivalent power, axial length, and axial length-to-corneal curvature ratio, although corneal curvature displayed no statistically significant nonlinear trend. Factors affecting SE changes included the presence of strabismus, the use of cycloplegia, baseline SE, and age. Conversely, changes in axial length solely correlated with baseline axial length and age. CONCLUSION: Highly hyperopic preschool children undergoing early intervention display a marked emmetropization tendency, though most still remain moderately to highly hyperopic, with the progression of refractive changes showing non-uniform patterns with respect to age.


Asunto(s)
Longitud Axial del Ojo , Hiperopía , Refracción Ocular , Humanos , Hiperopía/fisiopatología , Hiperopía/diagnóstico , Preescolar , Refracción Ocular/fisiología , Masculino , Estudios Retrospectivos , Femenino , Estudios de Seguimiento , Longitud Axial del Ojo/patología , Agudeza Visual/fisiología , Niño , Biometría , Córnea/fisiopatología , Córnea/patología , Enfermedades Hereditarias del Ojo
19.
Ophthalmic Physiol Opt ; 44(5): 977-986, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38563586

RESUMEN

INTRODUCTION: Research assuming linearity has concluded that corneal biomechanics are compromised in high myopia. We investigated whether this assumption was appropriate and re-examined these associations across different levels of myopia. METHODS: Myopic (spherical equivalent refraction, SER ≤ -0.50 D) eyes of 10,488 adults aged 40-69 years without any history of systemic and ocular conditions were identified in the UK Biobank. Ordinary least squares (OLS) regression was employed to test the linear association between corneal hysteresis (CH) or corneal resistance factor (CRF), separately, and SER while controlling for age, sex, corneal radius and intraocular pressure. Quantile regression (QR) was used to test the same set of associations across 49 equally spaced conditional quantiles of SER. RESULTS: In OLS regression, each standard deviation (SD) decrease in CH and CRF was associated with 0.08 D (95% CI: 0.04-0.12; p < 0.001) and 0.10 D (95% CI: 0.04-0.15; p < 0.001) higher myopia, respectively. However, residual analysis indicated that the linearity assumption was violated. QR revealed no evidence of a significant association between CH/CRF and SER in low myopia, but a significant (p < 0.05) positive association became evident from -2.78 D (0.06 and 0.08 D higher myopia per SD decrease in CH and CRF). The magnitude of association increased exponentially with increasing myopia: in the -5.03 D quantile, every SD decrease in CH and CRF was associated with 0.17 D (95% CI: 0.08-0.25; p < 0.001) and 0.21 D (95% CI: 0.10-0.31; p < 0.001) higher myopia. In the -8.63 D quantile, this further increased to 0.54 D (95% CI: 0.33-0.76; p < 0.001) and 0.67 D (95% CI: 0.41-0.93; p < 0.001) higher myopia per SD decrease in CH and CRF. CONCLUSIONS: Corneal biomechanics appeared compromised from around -3.00 D. These changes were observed to be exponential with increasing myopia.


Asunto(s)
Córnea , Presión Intraocular , Refracción Ocular , Humanos , Persona de Mediana Edad , Córnea/fisiopatología , Femenino , Masculino , Adulto , Anciano , Fenómenos Biomecánicos , Refracción Ocular/fisiología , Presión Intraocular/fisiología , Miopía/fisiopatología , Miopía/epidemiología , Elasticidad , Miopía Degenerativa/fisiopatología
20.
Eye Contact Lens ; 50(6): 255-258, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38652487

RESUMEN

OBJECTIVE: To evaluate the effects of rigid corneal lenses (RCL) in patients with keratoconus, based on eccentricity. METHODS: Eighty-four eyes from 84 patients were included in this retrospective comparative study. Based on the median value of eccentricity difference between the cornea and back surface of the RCL, the patients were divided into groups 1 (<0.08) and 2 (≥0.08). Visual acuity, refractive index, and corneal topography indices were compared before and three months after lens use. RESULTS: Visual acuity, astigmatism, refractive error, corneal curvature, and corneal thickness improved significantly in both groups. Apical power and anterior elevation improved significantly in group 1, with small differences in eccentricity, but not in group 2. Changes in apical power before and after lens use were significantly different between the two groups. CONCLUSION: The RCL was effective for the cornea of keratoconus, especially when the prescription was made with a small difference in eccentricity.


Asunto(s)
Lentes de Contacto , Córnea , Topografía de la Córnea , Queratocono , Refracción Ocular , Agudeza Visual , Humanos , Queratocono/fisiopatología , Queratocono/terapia , Estudios Retrospectivos , Agudeza Visual/fisiología , Femenino , Masculino , Adulto , Refracción Ocular/fisiología , Adulto Joven , Córnea/patología , Córnea/fisiopatología , Adolescente , Astigmatismo/fisiopatología , Astigmatismo/terapia , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...