Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Más filtros












Intervalo de año de publicación
1.
Food Chem ; 260: 283-288, 2018 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-29699671

RESUMEN

The majority of l-cysteine is obtained industrially by hydrolysis of animal materials, such as poultry feathers. Despite widespread belief, there is little evidence that human hair is used as a source material and its use is explicitly banned in the European Union (2000/63/EC decision). We developed an isotope ratio mass spectrometric (EA-IRMS) method to determine carbon and nitrogen isotopic ratio in cysteine preparations and related compounds, e.g. cystine and carbocysteine. A threshold relying on the 15N/14N was established to differentiate between hair and feathers; a value below 6.6‰ indicates a poultry feathers origin. Global uncertainty of measurement was found to be 0.1‰ for δ15N (sample size of 0.5-1.8 mg).


Asunto(s)
Cisteína/análisis , Plumas/química , Cabello/química , Espectrometría de Masas/métodos , Isótopos de Nitrógeno/análisis , Animales , Carbocisteína/análisis , Escherichia coli/química , Europa (Continente) , Humanos , Aves de Corral , Reproducibilidad de los Resultados
2.
J Pharm Biomed Anal ; 115: 39-47, 2015 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-26159351

RESUMEN

A stability-indicating method for the determination of S-carboxymethyl-L-cysteine and related degradation impurities in Exputex® 250mg/5mL syrup was developed in anion-exchange liquid chromatography mode. A forced degradation study supported the method development to ensure stability indicating conditions. Aqueous solutions of the active pharmaceutical ingredient and syrup samples at different pH-values were stress-tested in different thermal, light exposure and headspace conditions. One degradation product was detected in thermal stress studies at 60°C and 80°C in the pH range 5.0-7.0 and was identified by mass spectrometry as 5-oxo-thiomorpholine-3-carboxylic acid (lactam of carbocysteine). A second degradation product was only generated in moderately strong oxidizing conditions (0.5% H2O2 aqueous solution) and was identified as S-carboxymethyl-L-cysteine-(R/S)-sulphoxide (carbocysteine sulphoxide). The method was developed on a Zorbax SAX column, in isocratic mode. The mobile phase consisted of 200mM phosphate solution at pH 4.0 and acetonitrile (50:50 v/v) and UV detection was performed at a wavelength of 205nm. The method was linear for carbocysteine (R>0.9982) over a concentration range of 2.5-50µg/mL and 0.4-0.6mg/mL. Linearity for the impurities was shown from the LOQ to 50µg/mL. Specificity was verified and accuracy demonstrated for the active ingredient and its degradation products in syrup samples at 3 levels around their respective specification limits. Repeatability, intermediate precision and inter-laboratory reproducibility were assessed on three commercial batches, analyzed in triplicate by two operators at both the transferring and the receiving site and demonstrated a successful method transfer to the manufacturing quality control laboratory.


Asunto(s)
Carbocisteína/análogos & derivados , Cromatografía Líquida de Alta Presión/métodos , Expectorantes/análisis , Lactamas/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Administración Oral , Carbocisteína/análisis , Química Farmacéutica , Formas de Dosificación , Contaminación de Medicamentos , Estabilidad de Medicamentos , Estructura Molecular , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Oral Oncol ; 51(9): 805-18, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26170140

RESUMEN

The purpose of this systematic review and meta-analysis was to evaluate the diagnostic value of salivary biological markers in the diagnosis of head and neck carcinoma. Studies were gathered by searching Cochrane, EMBASE, LILACS, MEDLINE, and PubMed. The references were also crosschecked and a partial grey literature search was undertaken using Google Scholar. The methodology of selected studies was evaluated using the 14-item Quality Assessment Tool for Diagnostic Accuracy Studies. After a two-step selection process, 15 articles were identified and subjected to qualitative and quantitative analyses. The studies were homogeneous, and all had high methodological quality. Combined biomarkers demonstrated better accuracy with higher sensitivity and specificity than those tested individually. Furthermore, the salivary biomarkers reviewed predicted the early stages of head and neck carcinoma better than the advanced stages. A restricted set of five single biomarkers (interleukin-8, choline, pipecolinic acid, l-phenylalanine, and S-carboxymethyl-l-cysteine) as well as combined biomarkers demonstrated excellent diagnostic test accuracy. The present systematic review confirms the potential value of a selected set of salivary biomarkers as diagnostic tools for head and neck carcinoma.


Asunto(s)
Biomarcadores/análisis , Neoplasias de Cabeza y Cuello/diagnóstico , Saliva/química , Adulto , Anciano , Anciano de 80 o más Años , Carbocisteína/análisis , Colina/análisis , Neoplasias de Cabeza y Cuello/metabolismo , Humanos , Interleucina-8/análisis , Persona de Mediana Edad , Fenilalanina/análisis , Piperidinas/análisis , Sensibilidad y Especificidad , Adulto Joven
4.
J Pharm Biomed Anal ; 95: 1-10, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24637049

RESUMEN

For the impurity profiling of the mucolytic and anti-inflammatory drug carbocisteine a high performance liquid chromatographic (HPLC) method using corona charged aerosol detection (CAD) was developed and fully validated following the ICH guideline Q2(R1). The response was linear (R²>0.995) over a small concentration range (0.05-0.25 or 0.10-0.60% respectively) and a detection limit of at least 0.03% was registered. The separation was achieved on a mixed mode column combining hydrophobic C18 and strong cation exchange retention mechanisms using a mass spectrometer compatible volatile mobile phase consisting of trifluoroacetic acid 10 mM and acetonitrile 12% (V/V). Impurities, not assessable by HPLC-CAD such as the volatile chloroacetic acid and the unstable cysteine, were determined by quantitative NMR (qNMR) with maleic acid as internal standard and UV/vis spectroscopy after reaction with Ellman's reagent, respectively. Six batches of three different manufacturers were tested by means of those methods. The purity varied from below 99.0 to higher than 99.8 per cent. The major impurities of all batches were the starting material cystine and N,S-dicarboxymethylcysteine being a synthesis by-product.


Asunto(s)
Carbocisteína/análisis , Cromatografía Líquida de Alta Presión/métodos , Contaminación de Medicamentos , Espectroscopía de Resonancia Magnética/métodos , Espectrofotometría Ultravioleta/métodos , Estabilidad de Medicamentos
5.
Artículo en Portugués | LILACS | ID: lil-667053

RESUMEN

Este estudo teve como objetivo avaliar a estabilidade de xaropes contendo carbocisteína, submetidos à degradação forçada, utilizando Desenho Experimental Fatorial (DEF). Os fatores avaliados foram pH (5,0; 6,5; 8,0), presença ou ausência de EDTA dissódico e metabissulfito de sódio (0,1%). Para o estudo de degradação forçada, as formulações foram submetidas a estresse térmico (50 °C e 75% UR) e oxidação com peróxido de hidrogênio a 3%. Posteriormente, as formulações foram analisadas quanto ao pH, propriedades organolépticas e teor de fármaco por CLAE-UV, nos tempos 0, 15 e 35 dias. Os resultados mostraram que as formulações submetidas à degradação forçada sofreram uma diminuição no teor do fármaco, enquanto que o pH se manteve relativamente estável. Em relação a cor, apenas as formulações que não possuíam antioxidantes mostraram-se mais escuras. A análise dos resultados do DEF mostrou interação significativa (p<0,05) para os fatores pH/metabissulfito e EDTA/metabissulfito. As formulações contendo metabissulfito em pH 5,0 apresentaram maior degradação e as formulações com metabissulfito sem EDTA também não foram eficientes para impedir a degradação da carbocisteína.


The aim of this study was to use Factorial Design (FD) to assess the stability of carbocisteine syrups subjected to forced degradation. The factors assessed were pH (5.0; 6.5; 8.0), presence or absence of disodium EDTA and sodium metabisulfite (0.1%). For the study of forced degradation, the formulations were subjected to thermal stress (50°C and 75% RH) and oxidation with 3% hydrogen peroxide. The formulations were analyzed for pH, organoleptic properties and drug content by HPLC-UV, at 0, 15 and 35 days. The results showed that the formulations exposed to forced degradation suffered a fall in drug content, while the pH remained relatively stable. Regarding the color, only the formulations without antioxidant exhibited a darker coloration. The results of FD revealed significant interactions (p<0.05) for pH/metabisulfite and EDTA / metabisulfite. Formulations containing metabisulfite at pH 5.0 showed the greatest degradation and those with metabisulfite and without EDTA were also not effective in preventing the degradation of carbocisteine.


Asunto(s)
Carbocisteína/análisis , Estabilidad de Medicamentos , Expectorantes , Análisis Factorial
7.
J Fluoresc ; 17(3): 293-300, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17440799

RESUMEN

Two simple, sensitive and specific fluorimetric methods have been developed for the determination of some sulphur containing compounds namely, Acetylcysteine (Ac), Carbocisteine (Cc) and Thioctic acid (Th) using terbium Tb+3 and uranium U+3 ions as fluorescent probes. The proposed methods involve the formation of a ternary complex with Tb+3 in presence of Tris-buffer method (I) and a binary complex with aqueous uranyl acetate solution method (II). The fluorescence quenching of Tb+3 at 510, 488 and 540 nm (lambda(ex) 250, 241 and 268 nm) and of uranyl acetate at 512 nm (lambda(ex) 240 nm) due to the complex formation was quantitatively measured for Ac, Cc and Th, respectively. The reaction conditions and the fluorescence spectral properties of the complexes have been investigated. Under the described conditions, the proposed methods were applicable over the concentration range (0.2-2.5 microg ml(-1)), (1-4 microg ml(-1)) and (0.5-3.5 microg ml(-1)) with mean percentage recoveries 99.74+/-0.36, 99.70+/-0.52 and 99.43+/-0.23 for method (I) and (0.5-6 microg ml(-1)), (0.5-5 microg ml(-1)), and (1-6 microg ml(-1)) with mean percentage recoveries 99.38+/-0.20, 99.82+/-0.28 and 99.93+/-0.32 for method (II), for the three cited drugs, respectively. The proposed methods were successfully applied for the determination of the studied compounds in bulk powders and in pharmaceutical formulations, as well as in presence of their related substances. The results obtained were found to be in agree statistically with those obtained by official and reported ones. The two methods were validated according to USP guidelines and also assessed by applying the standard addition technique.


Asunto(s)
Espectrometría de Fluorescencia/métodos , Compuestos de Azufre/análisis , Terbio/química , Uranio/química , Acetilcisteína/análisis , Acetilcisteína/química , Carbocisteína/análisis , Carbocisteína/química , Colorantes Fluorescentes/química , Concentración de Iones de Hidrógeno , Estructura Molecular , Compuestos Organometálicos/química , Preparaciones Farmacéuticas/química , Reproducibilidad de los Resultados , Compuestos de Azufre/química , Ácido Tióctico/análisis , Ácido Tióctico/química
8.
J Chromatogr A ; 1026(1-2): 167-74, 2004 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-14763743

RESUMEN

A novel method for the determination of carbocisteine (S-CMC), a mucolytic and expectorant drug with an acidic amino acid structure, was developed and validated, using non-suppressed ion-chromatographic system with conductimetric detection, and anion or cation exchange columns. Among the various combinations of column type and eluent composition tested, a cation exchange column with a 0.25 mM tri-fluoroacetic acid (TFA) as eluent in isocratic mode at 1.2 ml/min gave the best results. S-CMC was very well separated from all common amino acids (resolution > 2.6). The retention time was 3.5 min and the asymmetry factor 1.1. A linear calibration curve from 17 to 400 microg/ml (r = 0.99994), with a detection limit of 0.14 microg (5.6 microg/ml-25 microl injection volume) and a precision of 1.5% R.S.D. (100 microg/ml, n = 3) was achieved. The proposed method was applied for the determination of S-CMC content in intensely colored commercial formulations (syrups). No interference from excipients was found and the only pretreatment step was the appropriate dilution with the mobile phase. Recovery from standard additions was ranged from 96.0 to 104.9% and precision (R.S.D., n = 3) 1.8-3.6%.


Asunto(s)
Carbocisteína/análisis , Cromatografía por Intercambio Iónico/métodos , Preparaciones Farmacéuticas/química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
9.
Bioconjug Chem ; 12(3): 406-13, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11353539

RESUMEN

Careful attention to technical issues preceded successful crystallography of the ligand-binding domain of estrogen receptor alpha (ERalpha) complexed with CP-336156, a nonsteroidal estrogen agonist/antagonist. An affinity column based on immobilized estradiol was prepared according to the scheme of Greene et al. (Greene, G. L., Nolan, C., Engler, J. P., and Jensen, E. V. (1980) Proc. Natl. Acad. Sci. U.S.A. 77, 5115-5119). It was shown by X-ray crystallography that the major and less polar isomer of the affinity column precursor was 17alpha-((S)-2',3'-epoxyprop-1'-yl)estra-1,3,5(10)-triene-3,17beta-diol. This diastereomer was coupled to Thiopropyl Sepharose, with coupling monitored by observing loss of the phenolic absorption band of estradiol from the reaction supernatant, and gave an affinity matrix containing about 9 micromol of estradiol per milliliter of wet gel. Recombinant ERalpha ligand binding domain was selectively removed from E. coli cell lysate by binding to the column and was partly S-carboxymethylated by treatment with iodoacetic acid while bound to the column as described by previous workers. After being eluted from the column as a complex with drug, the receptor fragment was shown by mass spectrometry to be a mixture of differently modified forms. It was further S-carboxymethylated in solution, after which anion-exchange chromatography was used to isolate protein in which two of the four cysteine residues were S-carboxymethylated. This material, which afforded diffraction-quality crystals, was subjected to digestion with trypsin and peptide mapping analysis by HPLC coupled with mass spectrometry. For this experiment, the two previously unmodified cysteines were alkylated with 4-vinylpyridine to allow definitive identification. It was shown that Cys-417 and Cys-530 were S-carboxymethylated in the crystallized protein, while Cys-381 and Cys-447 remained unmodified. Close attention to such technical issues may be important in structural studies of other nuclear receptors, a very important class of potential drug targets.


Asunto(s)
Receptores de Estrógenos/química , Receptores de Estrógenos/metabolismo , Secuencia de Aminoácidos , Sitios de Unión , Carbocisteína/análisis , Cromatografía de Afinidad , Cristalografía por Rayos X , Antagonistas de Estrógenos/química , Antagonistas de Estrógenos/metabolismo , Receptor alfa de Estrógeno , Humanos , Ligandos , Espectrometría de Masas , Datos de Secuencia Molecular , Estructura Molecular , Mapeo Peptídico , Estructura Terciaria de Proteína , Pirrolidinas/química , Pirrolidinas/metabolismo , Receptores de Estrógenos/aislamiento & purificación , Tetrahidronaftalenos/química , Tetrahidronaftalenos/metabolismo
10.
J Pharm Biomed Anal ; 25(1): 165-70, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11274870

RESUMEN

A simple reversed-phase high-performance liquid chromatography method was developed for the determination of s-carboxymethyl-l-cysteine in syrup preparations. The experiments were performed without specific sample pre-treatment. The LC conditions used were acetonitrile-10 mM sodium dihydrogenphosphate buffer, pH 2.0 (1:99, v/v) on a C(18) Inersil column with a flow rate of 1.5 ml/min. Ultraviolet detection was carried out at 240 nm. The method showed excellent linearity (r(2)>0.9998) over the concentration range tested (0.8-25.6 mg/ml) with good precision and accuracy (%R.S.D. 0.7%). Recoveries were good (>99%) with a limit of detection and limit of quantitation of 0.1 and 0.8 mg/ml. Other compositions in the syrup vehicle did not interfere the analysis of s-carboxymethyl-l-cysteine.


Asunto(s)
Carbocisteína/análisis , Cromatografía Líquida de Alta Presión/métodos , Calibración , Química Farmacéutica , Estabilidad de Medicamentos , Expectorantes/análisis , Estándares de Referencia , Reproducibilidad de los Resultados , Espectrofotometría Ultravioleta
11.
EXS ; 78: 239-58, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-8962496

RESUMEN

This overview emphasizes present aspects of sulfur-containing amino acids in hair. A selection of analytical procedures to determine cystine, cysteine, S-sulfocysteine, cystine oxide, cysteic acid, lanthionine and lysinoalanine are presented. The methods relate to intact hair or partial and total hydrolysates and comprise chromatography, titration, colorimetry, polarography and spectroscopy. For the analysis of cysteine, cystine and cystine oxides, polarography and spectroscopy are the methods of choice. Cysteic acid, lanthionine and lysinoalanine are analysed by means of ion-exchange chromatography (Spackman et al., 1958) after total hydrolysis.


Asunto(s)
Aminoácidos Sulfúricos/análisis , Cabello/química , Álcalis/farmacología , Aminoácidos Sulfúricos/química , Animales , Carbocisteína/análisis , Ácido Cisteico/análisis , Cisteína/análogos & derivados , Cisteína/análisis , Cisteína/química , Cistina/análisis , Cistina/química , Cabello/efectos de los fármacos , Tinturas para el Cabello/farmacología , Humanos , Estructura Molecular , Oxidantes/farmacología , Lana
13.
Eur J Drug Metab Pharmacokinet ; 13(4): 253-6, 1988.
Artículo en Inglés | MEDLINE | ID: mdl-3243319

RESUMEN

The metabolism of an oral dose of S-carboxymethyl-L-cysteine (SCMC) in man has been studied; the quantitative determination of SCMC, S-methyl-L-cysteine (SMC) and their sulphoxide metabolites (SCMCO and SMCO), in urine, was carried out using high performance liquid chromatography (HPLC) with electrochemical detection (ECD); the possibility of stereospecific sulphoxidation was investigated.


Asunto(s)
Carbocisteína/metabolismo , Cisteína/análogos & derivados , Carbocisteína/análisis , Cromatografía Líquida de Alta Presión , Cisteína/análisis , Humanos , Masculino , Sulfóxidos/análisis
15.
Biopharm Drug Dispos ; 9(1): 97-111, 1988.
Artículo en Inglés | MEDLINE | ID: mdl-3342289

RESUMEN

The aim of the present study was to evaluate the bioavailability of a new tablet formulation of carbocysteine relative against two other oral carbocysteine containing dosage forms, viz. a syrup and capsules. Plasma levels and urine concentrations of carbocysteine were monitored, following oral administration of all three dosage forms to healthy human volunteers, by direct derivatization of carbocysteine using dabsylchloride and subsequent high performance liquid chromatography. There was no difference in bioavailability of carbocysteine from these dosage forms as expressed by the respective areas under the plasma concentration-time curves and total amounts of unchanged carbocysteine excreted in urine.


Asunto(s)
Carbocisteína/farmacocinética , Cisteína/análogos & derivados , Administración Oral , Adulto , Disponibilidad Biológica , Cápsulas , Carbocisteína/administración & dosificación , Carbocisteína/análisis , Cromatografía Líquida de Alta Presión , Humanos , Masculino , Suspensiones , Comprimidos , Equivalencia Terapéutica
20.
Pharm Weekbl Sci ; 8(2): 134-8, 1986 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-3086832

RESUMEN

A method is described for the direct analysis of the amino acid carbocisteine in plasma and urine samples, following reaction with dabsyl chloride. Dabsylated carbocisteine is subjected to high pressure liquid chromatography with spectrophotometric detection at 425 nm. The usefulness of the method for bioavailability studies is discussed and compared with methods currently in use.


Asunto(s)
Carbocisteína/análisis , Cisteína/análogos & derivados , Disponibilidad Biológica , Carbocisteína/sangre , Carbocisteína/orina , Cromatografía Líquida de Alta Presión , Estabilidad de Medicamentos , Humanos , Concentración de Iones de Hidrógeno , p-Dimetilaminoazobenceno/análogos & derivados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...