A A Pract ; 18(5): e01785, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38727098

RESUMEN

This case series describes the safety and effectiveness of superficial parasternal intercostal plane catheters for poststernotomy pain control in 4 patients who underwent multivessel coronary artery bypass grafting. Patients had reduced sternal pain and opioid consumption while the catheters ran continuously for 72 hours without complications. Our experience suggests the effectiveness of parasternal blocks can be safely prolonged with catheters, and they can be a useful addition to pain management strategies for this patient population.


Asunto(s)
Bloqueo Nervioso , Dolor Postoperatorio , Esternotomía , Humanos , Dolor Postoperatorio/prevención & control , Dolor Postoperatorio/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Anciano , Femenino , Bloqueo Nervioso/métodos , Bloqueo Nervioso/instrumentación , Manejo del Dolor/métodos , Puente de Arteria Coronaria/métodos , Catéteres
2.
Anesthesiol Clin ; 42(2): 317-328, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38705679

RESUMEN

Continuous peripheral nerve block catheters are simple in concept: percutaneously inserting a catheter adjacent to a peripheral nerve. This procedure is followed by local anesthetic infusion via the catheter that can be titrated to effect for extended anesthesia or analgesia in the perioperative period. The reported benefits of peripheral nerve catheters used in the surgical population include improved pain scores, decreased narcotic use, decreased nausea/vomiting, decreased pruritus, decreased sedation, improved sleep, and improved patient satisfaction.


Asunto(s)
Catéteres , Bloqueo Nervioso , Humanos , Anestésicos Locales/administración & dosificación , Cateterismo/métodos , Bloqueo Nervioso/métodos , Nervios Periféricos
3.
BMC Pediatr ; 24(1): 325, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38734598

RESUMEN

BACKGROUND: Cerebrospinal fluid (CSF) shunts allow children with hydrocephalus to survive and avoid brain injury (J Neurosurg 107:345-57, 2007; Childs Nerv Syst 12:192-9, 1996). The Hydrocephalus Clinical Research Network implemented non-randomized quality improvement protocols that were shown to decrease infection rates compared to pre-operative prophylactic intravenous antibiotics alone (standard care): initially with intrathecal (IT) antibiotics between 2007-2009 (J Neurosurg Pediatr 8:22-9, 2011), followed by antibiotic impregnated catheters (AIC) in 2012-2013 (J Neurosurg Pediatr 17:391-6, 2016). No large scale studies have compared infection prevention between the techniques in children. Our objectives were to compare the risk of infection following the use of IT antibiotics, AIC, and standard care during low-risk CSF shunt surgery (i.e., initial CSF shunt placement and revisions) in children. METHODS: A retrospective observational cohort study at 6 tertiary care children's hospitals was conducted using Pediatric Health Information System + (PHIS +) data augmented with manual chart review. The study population included children ≤ 18 years who underwent initial shunt placement between 01/2007 and 12/2012. Infection and subsequent CSF shunt surgery data were collected through 12/2015. Propensity score adjustment for regression analysis was developed based on site, procedure type, and year; surgeon was treated as a random effect. RESULTS: A total of 1723 children underwent initial shunt placement between 2007-2012, with 1371 subsequent shunt revisions and 138 shunt infections. Propensity adjusted regression demonstrated no statistically significant difference in odds of shunt infection between IT antibiotics (OR 1.22, 95% CI 0.82-1.81, p = 0.3) and AICs (OR 0.91, 95% CI 0.56-1.49, p = 0.7) compared to standard care. CONCLUSION: In a large, observational multicenter cohort, IT antibiotics and AICs do not confer a statistically significant risk reduction compared to standard care for pediatric patients undergoing low-risk (i.e., initial or revision) shunt surgeries.


Asunto(s)
Antibacterianos , Profilaxis Antibiótica , Derivaciones del Líquido Cefalorraquídeo , Humanos , Derivaciones del Líquido Cefalorraquídeo/efectos adversos , Antibacterianos/administración & dosificación , Estudios Retrospectivos , Niño , Masculino , Preescolar , Femenino , Lactante , Profilaxis Antibiótica/métodos , Adolescente , Inyecciones Espinales , Hidrocefalia/cirugía , Catéteres de Permanencia/efectos adversos , Infección de la Herida Quirúrgica/prevención & control , Infecciones Relacionadas con Catéteres/prevención & control , Catéteres
4.
J Biol Inorg Chem ; 29(3): 353-373, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38744691

RESUMEN

Investigating the application of innovative antimicrobial surface coatings on medical devices is an important field of research. Many of these coatings have significant drawbacks, including biocompatibility, coating stability and the inability to effectively combat multiple drug-resistant bacteria. In this research, we developed an antibiofilm surface coating for medical catheters using biosynthesized silver nanoparticles (b-Cs-AgNPs) developed using leaves extract of Calliandra surinamensis. Various characterization techniques were employed to thoroughly characterize the synthesized b-Cs-AgNPs and c-AgNPs. b-Cs-AgNPs were compatible with human normal kidney cells and chicken embryos. It did not trigger any skin inflammatory response in in vivo rat model. b-Cs-AgNPs demonstrated potent zone of inhibition of 19.09 mm when subjected to the disc diffusion method in E. coli confirming strong antibacterial property. Different anti-bacterial assays including liquid growth curve, colony counting assay, biofilm formation assay supported the potent antimicrobial efficacy of b-Cs-AgNPs alone and when coated to medical grade catheters. Mechanistic studies reveal the presence of ferulic acid, that was important for the synthesis of b-AgNPs along with enhanced antibacterial effects of b-Cs-AgNPs compared to c-AgNPs, supported by molecular docking analysis. These results together demonstrated the effective role b-Cs-AgNPs in combating infections and mitigating biofilm formations, highlighting their need for further study in the field of biomedical applications.


Asunto(s)
Antibacterianos , Biopelículas , Catéteres , Nanopartículas del Metal , Plata , Animales , Biopelículas/efectos de los fármacos , Plata/química , Plata/farmacología , Nanopartículas del Metal/química , Antibacterianos/farmacología , Antibacterianos/química , Antibacterianos/síntesis química , Catéteres/microbiología , Pollos , Escherichia coli/efectos de los fármacos , Escherichia coli/fisiología , Pruebas de Sensibilidad Microbiana , Humanos , Embrión de Pollo , Ratas , Extractos Vegetales/farmacología , Extractos Vegetales/química , Hojas de la Planta/química , Hojas de la Planta/microbiología
5.
Braz J Cardiovasc Surg ; 39(2): e20230354, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748605

RESUMEN

Postoperative pain after cardiac surgery plays an important role in the patient's recovery process. In particular, pain at the chest tube site can negatively affect the comfort and recovery of these patients. Effective pain control minimizes the risk of many complications. Oral and intravenous analgesics, epidural anesthesia, paravertebral block, and intercostal nerve blockade are used in chest tube pain control. We routinely use the surgical cryoablation method in the presence of atrial fibrillation in the preoperative period of cardiac surgery in our clinic. Here we aimed to describe our method of using the cryoablation catheter for intercostal nerve blockade.


Asunto(s)
Fibrilación Atrial , Tubos Torácicos , Criocirugía , Dolor Postoperatorio , Humanos , Fibrilación Atrial/cirugía , Dolor Postoperatorio/prevención & control , Dolor Postoperatorio/etiología , Criocirugía/métodos , Criocirugía/instrumentación , Bloqueo Nervioso/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Nervios Intercostales , Resultado del Tratamiento , Catéteres
6.
J Vis Exp ; (205)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38587368

RESUMEN

Acute myocardial infarction (AMI) is a prevalent and high-mortality cardiovascular condition. Despite advancements in revascularization strategies for AMI, it frequently leads to myocardial ischemia-reperfusion injury (IRI), amplifying cardiac damage. Murine models serve as vital tools for investigating both acute injury and chronic myocardial remodeling in vivo. This study presents a unique closed-chest technique for remotely inducing myocardial IRI in mice, enabling the investigation of the very early phase of occlusion and reperfusion using in-vivo imaging such as MRI or PET. The protocol utilizes a remote occlusion method, allowing precise control over ischemia initiation after chest closure. It reduces surgical trauma, enables spontaneous breathing, and enhances experimental consistency. What sets this technique apart is its potential for simultaneous noninvasive imaging, including ultrasound and magnetic resonance imaging (MRI), during occlusion and reperfusion events. It offers a unique opportunity to analyze tissue responses in almost real-time, providing critical insights into processes during ischemia and reperfusion. Extensive systematic testing of this innovative approach was conducted, measuring cardiac necrosis markers for infarction, assessing the area at risk using contrast-enhanced MRI, and staining infarcts at the scar maturation stage. Through these investigations, emphasis was placed on the value of the proposed tool in advancing research approaches to myocardial ischemia-reperfusion injury and accelerating the development of targeted interventions. Preliminary findings demonstrating the feasibility of combining the proposed innovative experimental protocol with noninvasive imaging techniques are presented herein. These initial results highlight the benefit of utilizing the purpose-built animal cradle to remotely induce myocardial ischemia while simultaneously conducting MRI scans.


Asunto(s)
Infarto del Miocardio , Isquemia Miocárdica , Daño por Reperfusión Miocárdica , Ratones , Animales , Daño por Reperfusión Miocárdica/diagnóstico por imagen , Infarto del Miocardio/diagnóstico por imagen , Necrosis , Catéteres , Modelos Animales de Enfermedad
7.
J Vis Exp ; (205)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38587399

RESUMEN

Catheter-related infection (CRI) is a common nosocomial infection caused by candida albicans during catheter implantation. Typically, biofilms are formed on the outer surface of the catheter and lead to disseminated infections, which are fatal to patients. There are no effective prevention and treatment management in clinics. Therefore, it is urgent to establish an animal model of CRI for the preclinical screening of new strategies for its prevention and treatment. In this study, a polyethylene catheter, a widely used medical catheter, was inserted into the back of the BALB/c mice after hair removal. Candida albicans ATCC MYA-2876 (SC5314) expressing enhanced green fluorescent protein was subsequently inoculated on the skin's surface along the catheter. Intense fluorescence was observed on the surface of the catheter under a fluorescent microscope 3 days later. Mature and thick biofilms were found on the surface of the catheter via scanning electron microscopy. These results indicated the adhesion, colonization, and biofilm formation of candida albicans on the surface of the catheter. The hyperplasia of the epidermis and the infiltration of inflammatory cells in the skin specimens indicated the histopathological changes of the CRI-associated skin. To sum up, a mouse CRI model was successfully established. This model is expected to be helpful in the research and development of therapeutic management for candida albicans associated CRI.


Asunto(s)
Candida albicans , Infecciones Relacionadas con Catéteres , Humanos , Ratones , Animales , Catéteres , Modelos Animales de Enfermedad , Biopelículas , Antifúngicos
8.
Urolithiasis ; 52(1): 59, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38568426

RESUMEN

To evaluate the safety and efficacy of tubeless percutaneous nephrolithotomy (PCNL) in patients with Escherichia coli (E. coli) bacteriuria. We conducted a retrospective review of 84 patients with E. coli bacteriuria who underwent PCNL. Patients were divided into two groups according to whether a nephrostomy tube is placed at the end of the procedure. Preoperative clinical data, surgical outcomes, and postoperative complications were compared. Then, regression analysis of factors predicting success rate of PCNL in patients with E. coli bacteriuria was performed. After PCNL, residual fragments ≤ 4 mm were considered as success. At baseline, the two groups were similar with regard to age, gender, BMI, underlying disease, hydronephrosis, stone characteristics, and urinalysis. Postoperative fever occurred in 1 patient (3.8%) in the tubeless PCNL group, and in 5 patients (8.6%) in the conventional PCNL group (p > 0.05). There were no significant differences in terms of successful rate, decrease in hemoglobin, pain scores, blood transfusion, and hospitalization expenses. However, the tubeless PCNL group had significantly shorter operative time (60 vs. 70 min, p = 0.033), indwelling time of catheter (2 vs. 4 days, p < 0.001), and hospital stays (3 vs. 5 days, p < 0.001) than the conventional PCNL group. In the analysis of factors predicting success, the stone diameter, stone burden, and operative time were associated with success rate of PCNL. It is safe and effective to perform tubeless PCNL in patients with E. coli bacteriuria. Compared to conventional PCNL, tubeless PCNL accelerates patient recovery and shortens hospital stays.


Asunto(s)
Bacteriuria , Nefrolitotomía Percutánea , Humanos , Nefrolitotomía Percutánea/efectos adversos , Escherichia coli , Catéteres , Hospitalización
9.
A A Pract ; 18(4): e01771, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38578011

RESUMEN

Regional anesthesia nerve blocks are increasingly used for patients undergoing cardiac surgery as part of multimodal pain management. Though rare, local anesthetic systemic toxicity (LAST) is a severe complication that requires vigilant monitoring. We present a case of a postcardiac surgery patient who developed LAST multiple days after surgery from lidocaine via an erector spinae plane catheter. This episode was determined to be a result of impaired lidocaine metabolism from liver shock caused by worsening pulmonary hypertension. Even under continuous monitoring, patients with cardiac or liver dysfunction are at increased risk of complications from local anesthetics.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Bloqueo Nervioso , Humanos , Anestésicos Locales/efectos adversos , Dolor Postoperatorio/tratamiento farmacológico , Dolor Postoperatorio/etiología , Bloqueo Nervioso/efectos adversos , Lidocaína/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Catéteres/efectos adversos
12.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38587017

RESUMEN

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , América Latina , Resultado del Tratamiento , Catéteres , Asia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
13.
Int Wound J ; 21(4): e14795, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38572781

RESUMEN

This study investigates the effects of comprehensive nursing interventions on wound pain in patients undergoing catheter insertion for peritoneal dialysis. Sixty patients who underwent catheter insertion for peritoneal dialysis from January 2021 to January 2023 at our hospital were selected as subjects and randomly divided into an experimental group and a control group using a random number table method. The control group received routine nursing care, while the experimental group was subjected to comprehensive nursing interventions. The study compared the impact of nursing measures on visual analogue scale (VAS), self-rating anxiety scale (SAS), self-rating depression scale (SDS) and nursing satisfaction between the two groups. The analysis revealed that on the third, fifth and seventh days post-intervention, the experimental group's wound VAS scores were significantly lower than those of the control group (p < 0.001). Furthermore, levels of anxiety and depression were markedly lower in the experimental group compared with the control group (p < 0.001). In addition, the nursing satisfaction rate was significantly higher in the experimental group than in the control group (96.67% vs. 73.33%, p = 0.011). This study indicates that the application of comprehensive nursing interventions in patients undergoing catheter insertion for peritoneal dialysis is highly effective. It can alleviate wound pain and negative emotions to a certain extent, while also achieving high patient satisfaction, thus demonstrating significant clinical value.


Asunto(s)
Dolor , Diálisis Peritoneal , Humanos , Ansiedad/etiología , Ansiedad/terapia , Trastornos de Ansiedad , Catéteres
14.
J Clin Apher ; 39(3): e22111, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38634439

RESUMEN

The objective of this study was to assess the use of midline catheters as venous access for apheresis procedures in pediatric patients. A retrospective analysis of medical records was conducted from September 2019 to June 2022 to evaluate the safety and efficacy of midline catheters for therapeutic pediatric apheresis. During the study period, a total of 121 procedures were inserted in 22 unique patients. The age of the subjects ranged from 2.7 to 21 years. The blood flow rates achieved with midline catheters met or exceeded the recommended rates for apheresis in children (40 mL/min), by the Wilcoxon signed-rank test (p < 0.0001). There was one episode of catheter-related thrombosis, but no cases of bloodstream infection or catheter dislodgement were reported. In conclusion, this study supports the use of midline catheters as a safe and effective alternative for venous access during therapeutic and donor apheresis procedures in pediatric patients.


Asunto(s)
Eliminación de Componentes Sanguíneos , Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Cateterismo Periférico , Catéteres Venosos Centrales , Trombosis , Humanos , Niño , Preescolar , Adolescente , Adulto Joven , Adulto , Cateterismo Venoso Central/métodos , Estudios Retrospectivos , Catéteres , Eliminación de Componentes Sanguíneos/métodos , Cateterismo Periférico/métodos
15.
Eur Rev Med Pharmacol Sci ; 28(7): 2654-2661, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38639504

RESUMEN

OBJECTIVE: This study aimed to explore the effect of flipped venous catheters combined with spinal cord electrical stimulation on functional recovery in patients with sciatic nerve injury. PATIENTS AND METHODS: 160 patients with hip dislocation and sciatic nerve injury were divided into conventional release and flipped catheter + electrical stimulation groups according to the treatment methods (n=80). Motor nerve conduction velocity (MCV) and lower limb motor function were compared. Serum neurotrophic factors brain-derived neurotrophic factor (BDNF) and nerve growth factor (NGF) were compared. The frequency of complications and quality of life were also compared. RESULTS: The MCV levels of the common peroneal nerve and tibial nerve in the flipped catheter + electrical stimulation group were greater than the conventional lysis group (p<0.05). After treatment, the lower extremity motor score (LMEs) in the flipped catheter + electrical stimulation group was greater than the conventional lysis group (p<0.05). The serum levels of BDNF and NGF in the flip catheter + electrical stimulation group were higher than the conventional lysis group (p<0.05). The complication rate in the flipped catheter + electrical stimulation group was lower than in the conventional release group (6.25% vs. 16.25%, p<0.05). The quality-of-life score in the flip catheter + electrical stimulation group was greater than the conventional lysis group (p<0.05). CONCLUSIONS: The flipped venous catheter combined with spinal cord electrical stimulation can improve nerve conduction velocity, lower limb motor function, serum BDNF and NGF levels, reduce complications, and help improve the quality of life of sufferers with sciatic nerve injury. Chictr.org.cn ID: ChiCTR2400080984.


Asunto(s)
Factor Neurotrófico Derivado del Encéfalo , Neuropatía Ciática , Ratas , Animales , Humanos , Factor Neurotrófico Derivado del Encéfalo/metabolismo , Ratas Sprague-Dawley , Factor de Crecimiento Nervioso/metabolismo , Calidad de Vida , Neuropatía Ciática/metabolismo , Neuropatía Ciática/terapia , Médula Espinal/metabolismo , Nervio Ciático , Catéteres , Estimulación Eléctrica/métodos
16.
Br J Nurs ; 33(7): S28-S34, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38578937

RESUMEN

INTRODUCTION: First-insertion success rates for peripheral vascular access devices (PVADs) in patients with difficult venous access (DIVA) are low, which negatively affects staff workload, patient experience, and organizational cost. There is mixed evidence regarding the impact of a peripheral vascular access device with retractable coiled tip guidewire (GW; AccuCath™, BD) on the first-insertion success rate. The aim of this study is to investigate whether the use of long GW-PVADs, compared with standard PVADs, reduces the risk of first-time insertion failure, in patients admitted to emergency departments (EDs). METHODS AND ANALYSIS: A parallel-group, two-arm, randomized controlled trial will be carried out in two Australian EDs to compare long GW-PVADs (5.8 cm length) against standard care PVADs (short or long). Patients ≥18 years of age meeting DIVA criteria will be eligible for the trial. The sample size is 203 participants for each arm. Web-based central randomization will be used to ensure allocation concealment. Neither clinicians nor patients can be blinded to treatment allocation. Primary outcome is the first-insertion success rate. Secondary outcomes include the number of insertion attempts, time to insert PVAD, all-cause failure, dwell-time, patient-reported pain, serious adverse events, complications, subsequent vascular access devices required, patient satisfaction, staff satisfaction, and healthcare costs. Differences between the two groups will be analyzed using Cox proportional hazards regression. Cost-effectiveness analysis will also be conducted. Intention-to-treat analysis will be used. ETHICS AND DISSEMINATION: The study is approved by Metro South Ethics Committee (HREC/2022/QMS/82264) and Griffith University (2022/077). The findings will be published in a peer-reviewed journal. TRIAL REGISTRATION: ACTRN12622000299707.


Asunto(s)
Cateterismo Periférico , Hospitalización , Humanos , Administración Intravenosa , Australia , Cateterismo Periférico/efectos adversos , Catéteres , Servicio de Urgencia en Hospital , Ensayos Clínicos Controlados Aleatorios como Asunto , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años
17.
J Diabetes ; 16(4): e13536, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38599884

RESUMEN

AIMS: It is not clear whether there are differences in glycemic control between the Equil patch and the MMT-712 insulin pump. Our objective was to compare two types of insulin pumps in the treatment of type 2 diabetes mellitus (T2DM), using continuous glucose monitoring (CGM) metrics and profiles. METHODS: This was a randomized case-crossover clinical trial. Participants were hospitalized and randomly allocated to two groups and underwent two types of insulin pump treatments (group A: Equil patch-Medtronic MMT-712 insulin pump; group B: Medtronic MMT-712-Equil patch insulin pump) separated by a 1-day washout period. Glycemic control was achieved after 7-8 days of insulin pump therapy. Each patient received CGM for 5 consecutive days (from day 1 to day 5). On day 3 of CGM performance, the Equil patch insulin pump treatment was switched to Medtronic MMT-712 insulin pump treatment at the same basal and bolus insulin doses or vice versa. CGM metrics and profiles including glycemic variability (GV), time in range (TIR, 3.9-10.0 mmol/L), time below range (TBR, <3.9 mmol/L), time above range (TAR, >10.0 mmol/L), and postprandial glucose excursions, as well as incidence of hypoglycemia. RESULTS: Forty-six T2DM patients completed the study. There was no significant difference in parameters of daily GV and postprandial glucose excursions between the Equil patch insulin pump treatment and the Medtronic insulin pump treatment. Similarly, there was no between-treatment difference in TIR, TBR, and TAR, as well as the incidence of hypoglycemia. CONCLUSION: The Equil patch insulin pump was similar to the traditional MMT-712 insulin pump in terms of glycemic control. Equil patch insulin pump is a reliable tool for glycemic management of diabetes mellitus.


Asunto(s)
Diabetes Mellitus Tipo 2 , Hipoglucemia , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea , Catéteres , Monitoreo Continuo de Glucosa , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Glucosa , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Estudios Cruzados
18.
Antimicrob Resist Infect Control ; 13(1): 38, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38600526

RESUMEN

BACKGROUND: Most surveillance systems for catheter-related bloodstream infections (CRBSI) and central line-associated bloodstream infections (CLABSI) are based on manual chart review. Our objective was to validate a fully automated algorithm for CRBSI and CLABSI surveillance in intensive care units (ICU). METHODS: We developed a fully automated algorithm to detect CRBSI, CLABSI and ICU-onset bloodstream infections (ICU-BSI) in patients admitted to the ICU of a tertiary care hospital in Switzerland. The parameters included in the algorithm were based on a recently performed systematic review. Structured data on demographics, administrative data, central vascular catheter and microbiological results (blood cultures and other clinical cultures) obtained from the hospital's data warehouse were processed by the algorithm. Validation for CRBSI was performed by comparing results with prospective manual BSI surveillance data over a 6-year period. CLABSI were retrospectively assessed over a 2-year period. RESULTS: From January 2016 to December 2021, 854 positive blood cultures were identified in 346 ICU patients. The median age was 61.7 years [IQR 50-70]; 205 (24%) positive samples were collected from female patients. The algorithm detected 5 CRBSI, 109 CLABSI and 280 ICU-BSI. The overall CRBSI and CLABSI incidence rates determined by automated surveillance for the period 2016 to 2021 were 0.18/1000 catheter-days (95% CI 0.06-0.41) and 3.86/1000 catheter days (95% CI: 3.17-4.65). The sensitivity, specificity, positive predictive and negative predictive values of the algorithm for CRBSI, were 83% (95% CI 43.7-96.9), 100% (95% CI 99.5-100), 100% (95% CI 56.5-100), and 99.9% (95% CI 99.2-100), respectively. One CRBSI was misclassified as an ICU-BSI by the algorithm because the same bacterium was identified in the blood culture and in a lower respiratory tract specimen. Manual review of CLABSI from January 2020 to December 2021 (n = 51) did not identify any errors in the algorithm. CONCLUSIONS: A fully automated algorithm for CRBSI and CLABSI detection in critically-ill patients using only structured data provided valid results. The next step will be to assess the feasibility and external validity of implementing it in several hospitals with different electronic health record systems.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Infección Hospitalaria , Sepsis , Humanos , Femenino , Persona de Mediana Edad , Infección Hospitalaria/epidemiología , Infección Hospitalaria/microbiología , Estudios Prospectivos , Estudios Retrospectivos , Infecciones Relacionadas con Catéteres/diagnóstico , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/microbiología , Catéteres , Algoritmos
19.
Medicine (Baltimore) ; 103(16): e37849, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38640270

RESUMEN

INTRODUCTION: Left-sided inferior vena cava (IVC) is an uncommon condition with a prevalence rate of 0.2% to 0.5%. Most of them remain asymptomatic and are discovered incidentally. The patient condition in this case is critical, and conventional procedures are not applicable. The surgical approach being considered is innovative, but it carries significant risks and uncertain therapeutic efficacy. PATIENT CONCERNS: A 42-year-old male presented with acute right lower extremity pain with swelling for 2 days. DIAGNOSIS: The patient was subsequently diagnosed with acute right lower extremity deep vein thrombosis, inferior vena cava thrombosis, and a left-sided IVC. INTERVENTIONS: Based on the treatment guidelines for lower extremity deep venous thrombosis. OUTCOMES: We successfully cured him with percutaneous mechanic thrombectomy (PMT) combined with catheter directed thrombolysis (CDT). CONCLUSION AND SIGNIFICANCE: The relatively low incidence of left-sided IVC does not diminish the significance of its identification. PMT combined with CDT is a safe way to treat acute thrombosis. It provides a new approach for similar patients in the future.


Asunto(s)
Terapia Trombolítica , Trombosis de la Vena , Humanos , Masculino , Adulto , Terapia Trombolítica/métodos , Fibrinolíticos/uso terapéutico , Vena Cava Inferior , Extremidad Inferior/irrigación sanguínea , Trombosis de la Vena/tratamiento farmacológico , Trombectomía/métodos , Catéteres , Resultado del Tratamiento
20.
Sci Rep ; 14(1): 9111, 2024 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-38643229

RESUMEN

Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) may be useful in treating exsanguinating trauma patients. This study seeks to compare rates of success, complications and time required for vascular access between ultrasound-guidance and surgical cut-down for femoral sheath insertion as a prospective observational case control study. Participating clinicians from either trauma surgery or anesthesiology were allocated to surgical cut-down or percutaneous ultrasound-guided puncture on a 1:1 ratio. Time spans to vessel identification, successful puncture, and balloon inflation were recorded. 80 study participants were recruited and allocated to 40 open cut-down approaches and 40 percutaneous ultrasound-guided approaches. REBOA catheter placement was successful in 18/40 cases (45%) using a percutaneous ultrasound guided technique and 33/40 times (83%) using the open cut-down approach (p < 0.001). Median times [in seconds] compared between percutaneous ultrasound-guided puncture and surgical cut-down were 36 (18-73) versus 117(56-213) for vessel visualization (p < 0.001), 136 (97-175) versus 183 (156-219) for vessel puncture (p < 0.001), and 375 (240-600) versus 288 (244-379) for balloon inflation (p = 0.08) overall. Access to femoral vessels for REBOA catheter placement is safer when performed by cut-down and direct visualization but can be performed faster by an ultrasound-guided technique when vessels can be identified clearly and rapidly.


Asunto(s)
Oclusión con Balón , Procedimientos Endovasculares , Choque Hemorrágico , Humanos , Estudios de Casos y Controles , Procedimientos Endovasculares/métodos , Hemorragia/etiología , Aorta/diagnóstico por imagen , Aorta/cirugía , Resucitación/métodos , Oclusión con Balón/métodos , Catéteres/efectos adversos , Ultrasonografía Intervencional/efectos adversos , Choque Hemorrágico/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA