Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 435
Filtrar
2.
Front Endocrinol (Lausanne) ; 12: 784706, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34899614

RESUMEN

Background: Adrenocorticotropic hormone (ACTH) is widely used in adrenal vein sampling (AVS) and can be administered as a bolus injection or continuous infusion. The optimal administration method has not been determined. We aimed to compare the effects of ACTH bolus with infusion on cannulation success, lateralization assessment and adverse events (AEs). Methods: Retrospectively collected data from patients with primary aldosteronism who underwent AVS with ACTH at a tertiary hospital in China. Rate of successful cannulation, lateralization index (LI), complete biochemical remission and AEs related to AVS were analyzed. Results: The study included 80 patients receiving ACTH bolus and 94 receiving infusions. The rate of successful cannulation was comparable between bolus and infusion groups (75/80, 93.4% vs 88/94, 93.6%). In those with successful cannulation, the bolus group had a higher selectivity index than the infusion group, while LI [6.4(1.8-17.5) vs. 7.6(2.0-27.8), P=0.48] and rate of complete biochemical remission (43/44, 97.7% vs 53/53, 100%, P=0.45) did not significantly differ between the two groups. One in the bolus and one patient in the infusion group had adrenal vein rupture but they recovered with conservative treatment. The bolus group reported more transient AEs such as palpitation (52.9% vs 2.2%) and abdominal discomfort (40.0% vs 2.2%) than the infusion group. Conclusions: Due to their similar effects on cannulation success and lateralization, but a lower rate of transient AEs in the infusion group, the continuous infusion method should be recommended for ACTH stimulation in AVS.


Asunto(s)
Glándulas Suprarrenales/irrigación sanguínea , Hormona Adrenocorticotrópica/administración & dosificación , Recolección de Muestras de Sangre/métodos , Hiperaldosteronismo/sangre , Glándulas Suprarrenales/efectos de los fármacos , Adulto , Recolección de Muestras de Sangre/normas , Cateterismo/métodos , Cateterismo/normas , Femenino , Humanos , Hiperaldosteronismo/tratamiento farmacológico , Infusiones Intravenosas , Inyecciones Intravenosas , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
3.
Turk J Gastroenterol ; 32(1): 1-10, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33893761

RESUMEN

Endoscopic retrograde cholangiopancreatography (ERCP) is technically demanding and carries significant risks. It is performed by gastrointestinal and surgical endoscopists. There is no consensus on the minimum number of ERCPs required during training. This study was conducted to analyze the minimum number of clinical ERCPs that a trainee needs to perform to achieve competency. PubMed, Ovid-Embase, and the Cochrane library were searched systematically for prospective and retrospective studies reporting on trainees' ERCP performance. Mete-analysis was conducted to analyze the success rate of cannulation, other basic techniques, and adverse event rate, using the random-effect model with Review Manager 5.3. Thirteen studies met the inclusion criteria, with 149 trainees performing a total of 18 794 ERCP procedures. The pooled cannulation success rate was 85.7% (95% CI: 78.1%-91.0%) at completion of training. The cannulation success rate was 76.5% (95% CI: 69.2%-82.5%) when the trainees had completed 180 ERCPs, which increased to 81.8% (95% CI: 69.8%-90.6%) after 200 ERCP procedures. Adverse events and post-ERCP pancreatitis rates were 4.7% (95% CI: 2.9%-9.1%) and 2.0% (0.9%-3.9%), respectively. Achieving a cannulation success rate of >90% was considered a quality indicator for ERCP training by most societal guidelines. However, our retrospective analysis indicated that trainees only attained a pooled cannulation success rate of only 81.8% after 200 procedures. Therefore, the minimum number of ERCPs required to achieve competency during training may need to be redefined to meet the basic requirement.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica , Competencia Clínica , Gastroenterología , Cateterismo/normas , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Colangiopancreatografia Retrógrada Endoscópica/normas , Competencia Clínica/normas , Endoscopía del Sistema Digestivo/educación , Endoscopía del Sistema Digestivo/normas , Gastroenterología/educación , Gastroenterología/normas , Humanos , Curva de Aprendizaje
4.
J Surg Res ; 264: 16-19, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33744773

RESUMEN

BACKGROUND: Although literature is sparse, there are guidelines regarding optimal placement technique for peritoneal dialysis (PD) catheters in the pediatric population. Through this study, we sought to identify commonly used techniques among pediatric surgeons and identify areas for future work. MATERIALS AND METHODS: A 16-question anonymous survey was emailed to American Pediatric Surgery Association members in September 2018 regarding routine practices for PD catheter placement. Descriptive statistics and Fisher's exact test were used for analysis. RESULTS: In all, there were 221 respondents, 6.8% of whom did not place PD catheters in their practice. Of the remaining 206, the majority have been in practice >15 y. PD catheter placement during fellowship training varied widely, with 6.5% reporting no fellowship experience to 6% reporting >25 placed during fellowship. Almost half (48%) reported placing catheters via laparoscopic approach (versus open or combined approach). Most (62%) respondents reported an annual practice volume of 1-5 catheters, with only 11% placing >10 per year. Exit-site sutures were placed "always" by 33% of participants and "never" by 49% of participants. There was no association between years in practice or fellowship experience and exit-site suture placement. However, there was a trend for "never" placement (72%) with more recent graduates. Omentectomy was performed by 91% of respondents, whereas 8.3% reported never performing omentectomy/omentopexy. Similarly, there was no association between practice and fellowship experience and omentectomy. In the setting of abdominal stoma, 96% reported placing the exit site on the opposite side of the abdomen. Fibrin glue was used along the tunnel by 21% of participants, ranging from "always" to "sometimes", whereas 79% "never" used it. CONCLUSIONS: Fellowship, posttraining experience, and techniques in PD catheter placement vary widely among American Pediatric Surgery Association member respondents. Despite guidelines, practices differ among providers without an association between the number of cases performed in fellowship and postfellowship volume.


Asunto(s)
Cateterismo/estadística & datos numéricos , Adhesión a Directriz/estadística & datos numéricos , Diálisis Peritoneal/instrumentación , Guías de Práctica Clínica como Asunto , Pautas de la Práctica en Medicina/estadística & datos numéricos , Adolescente , Cateterismo/normas , Catéteres de Permanencia , Niño , Preescolar , Competencia Clínica/estadística & datos numéricos , Humanos , Lactante , Recién Nacido , Internado y Residencia/estadística & datos numéricos , Fallo Renal Crónico/terapia , Epiplón/cirugía , Diálisis Peritoneal/normas , Pautas de la Práctica en Medicina/normas , Cirujanos/educación , Cirujanos/normas , Cirujanos/estadística & datos numéricos , Encuestas y Cuestionarios/estadística & datos numéricos
6.
J Vasc Access ; 22(3): 450-456, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-32648805

RESUMEN

Cannulation is essential for haemodialysis with arteriovenous access, but also damages the arteriovenous access making it prone to failure, is associated with complications and affects patients' experiences of haemodialysis. Managing Access by Generating Improvements in Cannulation is a national UK quality improvement project, designed to improve cannulation practice in the United Kingdom, ensuring it reflects current needling recommendations. It uses a simple quality improvement method, the Model for Improvement, to structure improvement to cannulation practice. It assists units in the practical implementation of the British Renal Society and Vascular Access Society of Britain and Ireland needling recommendations, ensuring actual cannulation practice reflects what is defined as best practice in cannulation. An eLearning package and awareness materials have been developed, to assist units in changing their cannulation practice. The Kidney Quality Improvement Partnership provides a structure for Managing Access by Generating Improvements in Cannulation that promotes development and dissemination. It is hoped that Managing Access by Generating Improvements in Cannulation will raise an understanding about the cannulation of arteriovenous access and change behaviours and beliefs around correct cannulation practice, to ensure longevity of this lifeline.


Asunto(s)
Derivación Arteriovenosa Quirúrgica/normas , Implantación de Prótesis Vascular/normas , Cateterismo/normas , Evaluación de Procesos y Resultados en Atención de Salud/normas , Mejoramiento de la Calidad/normas , Indicadores de Calidad de la Atención de Salud/normas , Diálisis Renal/normas , Derivación Arteriovenosa Quirúrgica/efectos adversos , Actitud del Personal de Salud , Benchmarking/normas , Implantación de Prótesis Vascular/efectos adversos , Cateterismo/efectos adversos , Competencia Clínica/normas , Conocimientos, Actitudes y Práctica en Salud , Humanos , Capacitación en Servicio/normas , Evaluación de Programas y Proyectos de Salud , Factores de Tiempo , Resultado del Tratamiento , Reino Unido
7.
Adv Chronic Kidney Dis ; 27(4): 344-349.e1, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-33131648

RESUMEN

The nephrologist has a pivotal role as the leader of multidisciplinary teams to optimize vascular access care of the patient on dialysis and to promote multidisciplinary collaboration in research, training, and education. The continued success of interventional nephrology as an independent discipline depends on harnessing these efforts to advance knowledge and encourage innovation. A comprehensive curriculum that encompasses research from bench to bedside coupled with standardized clinical training protocols are fundamental to this expansion. As we find ourselves on the threshold of a much-awaited revolution in nephrology, there is great opportunity but also formidable challenges in the field - it is up to us to work together to realize the enormous potential of our discipline.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Cateterismo , Nefrólogos , Nefrología/educación , Rol del Médico , Diálisis Renal , Derivación Arteriovenosa Quirúrgica/normas , Cateterismo/normas , Catéteres de Permanencia , Certificación , Fluoroscopía , Humanos , Riñón/diagnóstico por imagen , Laparoscopía , Nefrólogos/normas , Nefrología/normas , Nefrología/tendencias , Diálisis Peritoneal , Calidad de la Atención de Salud , Ultrasonografía
8.
Intern Med ; 59(14): 1687-1693, 2020 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-32296000

RESUMEN

Objective We investigated the results of biliary cannulation using a short-type single-balloon enteroscope in patients with a native papilla who had previously undergone Roux-en-Y gastrectomy and analyzed the factors associated with successful cannulation. Methods The study subjects consisted of patients with a native papilla who had previously undergone Roux-en-Y gastrectomy and endoscopic retrograde cholangiopancreatography using a short-type single-balloon enteroscope at our institution between September 2011 and July 2019. We carried out a retrospective investigation of the outcomes, including assessing the success rate of biliary cannulation, and analyzed the factors associated with successful cannulation. Results In total, 78 patients underwent biliary cannulation of a native papilla. The success rate of biliary cannulation was 80.8% (88.5% when including success on repeated attempts). The success rate of the standard cannulation technique was 60.3%, with the use of advanced cannulation techniques to secure the pancreatic duct providing the same additional effect as a normal anatomy. Adverse events occurred in 9.0% of cases. A multivariate analysis of the Roux-en-Y gastrectomy patients found that cannulation was more likely to be successful in patients in whom the scope could be placed in the retroflex position (odds ratio: 7.88, 95% confidence interval: 2.19-37.77, p<0.001). Conclusion Selective biliary cannulation using a short-type single-balloon enteroscope in patients with a native papilla who had undergone Roux-en-Y gastrectomy was effective and safe. The retroflex position provided a good papilla field of view and improved the success rate of biliary cannulation.


Asunto(s)
Anastomosis en-Y de Roux/efectos adversos , Enteroscopia de Balón/normas , Sistema Biliar , Cateterismo/normas , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Gastrectomía/normas , Conductos Pancreáticos/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Estudios Retrospectivos
9.
Intern Emerg Med ; 15(6): 1075-1079, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32133576

RESUMEN

Gastrostomy tubes (G-tubes) are frequently used in children for feeding and nutrition. Complications related to G-tubes (and G-buttons) in children represent a common presentation to the emergency department (ED). G-tube replacement is usually performed by pediatric emergency medicine physicians. Misplacement may lead to tract disruption, perforation, fistula tract formation, or feeding into the peritoneum. Contrast-enhanced radiographs are traditionally used for confirmation. In addition to a longer length-of-stay, repeat ED visits result in repeated radiation exposure. The use of point-of-care ultrasound (POCUS) instead of radiography avoids this exposure to ionizing radiation. Here, we describe three patients who presented with G-tube complications in whom POCUS alone performed by pediatricians was used for confirmation of the tubes' replacement. Two children presented to the ED with G-tube dislodgement, and one child presented with a ruptured balloon. In all three cases, a new G-tube was replaced at the bedside using POCUS guidance without the need for further radiographic studies. There were no known ED or clinic returns for G-tube complaints over the next 30 days. This is the first report of pediatricians using POCUS to guide and confirm G-tube replacement in children. The success of these cases suggests the technique's feasibility. Future prospective studies are needed to evaluate the learning curves, diagnostic accuracy, ED length-of-stay, and use of confirmatory imaging.


Asunto(s)
Cateterismo/normas , Gastrostomía/instrumentación , Ultrasonografía/métodos , Cateterismo/estadística & datos numéricos , Preescolar , Servicio de Urgencia en Hospital/organización & administración , Servicio de Urgencia en Hospital/estadística & datos numéricos , Femenino , Gastrostomía/estadística & datos numéricos , Humanos , Lactante , Masculino , Medicina de Urgencia Pediátrica/instrumentación , Medicina de Urgencia Pediátrica/métodos , Sistemas de Atención de Punto/normas , Sistemas de Atención de Punto/estadística & datos numéricos , Estudios Prospectivos , Estudios Retrospectivos , Ultrasonografía/estadística & datos numéricos
10.
J Emerg Med ; 57(6): 852-858, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31635927

RESUMEN

BACKGROUND: Commonly used ultrasound-guided internal jugular vein (IJV) cannulation techniques, short axis out of plane and long axis in-plane, have significantly reduced complications but failed to eliminate them because of technical difficulties. OBJECTIVE: This article describes a new anteroposterior short axis in-plane technique that combines advantage of in-plane technique to track the needle tip and short axis view of visualizing nearby anatomical structures by placing the probe on the side of the neck, oriented anteroposteriorly, perpendicular to the long axis of neck. This view visualizes IJV and its relationship to the carotid artery in short axis. The puncture needle is passed in-plane anteroposteriorly from the anterior aspect of the neck. Visualizing the needle, carotid artery, and IJV in single frame minimizes complications. METHODS: A prospective evaluative clinical trial was conducted in patients who require IJV cannulation for various reasons by performers experienced in ultrasound-guided IJV cannulations. The efficacy of the technique is indicated by 3 primary outcome measures: access time, number of attempts and success rate, and safety by secondary outcome measure, which is the incidence of mechanical complications. RESULTS: Seventy-five patients were enrolled. The average number of attempts was 1.17 (standard deviation 0.44), the access time was 27.12 s (standard deviation 21.47), and the success rate was 100%. This technique had 12% incidence of posterior venous wall punctures and 2.66% misplacements and no other complications. CONCLUSION: Anteroposterior short axis in-plane technique is relatively novel and could be alternatively used safely and effectively in place of existing techniques for IJV cannulation.


Asunto(s)
Cateterismo/métodos , Venas Yugulares/anatomía & histología , Ultrasonografía Intervencional/métodos , Ultrasonografía Intervencional/normas , Adulto , Anciano , Anciano de 80 o más Años , Cateterismo/normas , Cateterismo Venoso Central/métodos , Cateterismo Venoso Central/normas , Femenino , Humanos , Venas Yugulares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ultrasonografía Intervencional/estadística & datos numéricos
11.
Kidney Blood Press Res ; 44(6): 1383-1391, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31618744

RESUMEN

BACKGROUND: Unplanned start of renal replacement therapy is common in patients with end-stage renal disease and often accomplished by hemodialysis (HD) using a central venous catheter (CVC). Urgent start using peritoneal dialysis (PD) could be an alternative for some of the patients; however, this requires a hospital-based PD center that offers a structured urgent start PD (usPD) program. METHODS: In this prospective study, we describe the implementation of an usPD program at our university hospital by structuring the process from presentation to PD catheter implantation and start of PD within a few days. For clinical validation, we compared the patient flow before (2013-2015) and after (2016-2018) availability of usPD. RESULTS: In the 3 years before the availability of usPD, 14% (n = 12) of incident PD patients (n = 87) presented in an unplanned situation and were initially treated with HD using a CVC. In the 3 years after implementation of the usPD program, 18% (n = 18) of all incident PD patients (n = 103) presented in an unplanned situation of whom n = 12 (12%) were treated with usPD and n = 6 (6%) with initial HD. usPD significantly reduced the use of HD by 57% (p = 0.0005). Hospital stay was similar in patients treated with usPD (median 9 days) compared to those with elective PD (8 days), and significantly lower than in patients with initial HD (26 days, p = 0.0056). CONCLUSIONS: Implementation of an usPD program reduces HD catheter use and hospital stay in the unplanned situation.


Asunto(s)
Catéteres Venosos Centrales , Fallo Renal Crónico/terapia , Tiempo de Internación , Diálisis Peritoneal/métodos , Diálisis Renal , Cateterismo/métodos , Cateterismo/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diálisis Peritoneal/normas , Estudios Prospectivos , Diálisis Renal/instrumentación
13.
Eur J Gastroenterol Hepatol ; 31(10): 1200-1205, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31464778

RESUMEN

OBJECTIVE: In European Society of Gastrointestinal Endoscopy guidelines, biliary cannulation of native papilla is defined as difficult in the presence of >5 papilla contacts, >5 min cannulation time or >1 unintended pancreatic duct cannulation (5-5-2). The aim is to test 5-5-2-criteria in a single-center practice predicting the risk of post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP), and to study the efficacy of transpancreatic biliary sphincterotomy (TPBS) as an advanced method for biliary cannulation. METHODS: Prospectively collected data of 821 patients with native papilla were analyzed. Primary cannulation was the first method chosen for cannulation (sphincterotome and a guidewire). Advanced cannulation method was endoscopist-chosen cannulation method after failed primary cannulation. RESULTS: Primary cannulation succeeded in 599 (73%) patients in a median of 2 min. TPBS ± needle knife resulted in a 90% success rate. The final cannulation success was 814 (99.1%) cases in a median of 5.3 min. PEP risk was 4.0%. When primary cannulation succeeded, the PEP rate was 2.3%. When advanced methods were needed, the PEP rate increased to 13.5%. Altogether 311 (37.9%) patients fulfilled at least one 5-5-2-criterion. In patients without 5-5-2-criteria, the primary cannulation succeeded in 79.6% (n = 477), compared to 20.4% (n = 122) with the criteria, P < 0.001, indicating the need to exchange the cannulation method instead of persistence. If all the 5-5-2-criteria were present, the risk of PEP was 12.7%. CONCLUSION: The results support the use of the 5-5-2-criteria for difficult cannulation. TPBS is an effective advanced cannulation method with an acceptable complication rate.


Asunto(s)
Ampolla Hepatopancreática/cirugía , Cateterismo/normas , Colangiopancreatografia Retrógrada Endoscópica/normas , Pancreatitis/prevención & control , Complicaciones Posoperatorias/prevención & control , Esfinterotomía Endoscópica/normas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Ampolla Hepatopancreática/diagnóstico por imagen , Cateterismo/métodos , Niño , Colangiopancreatografia Retrógrada Endoscópica/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Pancreatitis/epidemiología , Pancreatitis/etiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Guías de Práctica Clínica como Asunto , Estudios Prospectivos , Esfinterotomía Endoscópica/métodos , Factores de Tiempo , Adulto Joven
15.
J Ren Care ; 45(4): 232-238, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31448871

RESUMEN

BACKGROUND: Arteriovenous dialysis access, fistulae (AVF) or grafts (AVG), are associated with significant rates of thrombosis. Timely thrombectomy may have a significant impact on immediate and long-term access survival. However, switching to a catheter is associated with higher rates of morbidity and mortality compared with those who have an AVF or AVG. OBJECTIVES: The goal of this study was to evaluate whether time to thrombectomy increases the risk for loss of dialysis access and subsequent placement of a dialysis catheter at hospital discharge, at 6 months, 12 months, and data at any time after discharge. METHODS: Using retrospective data, 444 patients were identified as having undergone thrombectomy for dialysis access dysfunction between January 2008 and April 2015, with 122 hospital admissions primarily for thrombectomy. RESULTS: The mean age was 60.4 years, 65% were male, and 44.3% had an arteriovenous fistula as their dialysis access. The mean time to thrombectomy was 10.8 hours, and 14 patients utilised a catheter for haemodialysis as primary access upon discharge. After adjustment for prior access intervention, access type, and time to thrombectomy, the adjusted odds ratios (AOR) of a one-day delay in thrombectomy was associated with a twofold increase in requirement for catheter at discharge and at 6 months. This association remained present at any time after discharge. CONCLUSION: In this study of patients cared for within an academic health system, a single day delay in thrombectomy nearly doubled the risk of needing a dialysis catheter at hospital discharge, 6 months, or any time after discharge.


Asunto(s)
Cateterismo/normas , Catéteres de Permanencia/efectos adversos , Trombectomía/normas , Factores de Tiempo , Adulto , Anciano , Fístula Arteriovenosa , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diálisis Renal/instrumentación , Diálisis Renal/métodos , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/terapia , Estudios Retrospectivos , Factores de Riesgo , Trombectomía/clasificación , Resultado del Tratamiento
16.
Am J Crit Care ; 28(4): 290-298, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31263012

RESUMEN

BACKGROUND: Indwelling urinary and vascular catheters are a common cause of health care-associated infections. Interventions designed to reduce catheter use can be ineffective if they are not integrated into the workflow and communication streams of busy clinicians. OBJECTIVES: To characterize communication barriers between physicians and nurses and to understand how these barriers affect appropriate use and removal of indwelling urinary and vascular catheters. METHODS: Individual and small-group semistructured interviews were conducted with physicians and nurses in a progressive care unit of an academic hospital. Common themes were identified, analyzed, and then organized using a conceptual framework of contextual barriers to communication: organizational, cognitive, and social complexity. RESULTS: Several barriers to communication between physicians and nurses contributed to inappropriate use and delayed removal of catheters. Workflow misalignment between clinicians was a barrier associated with organizational complexity, issues with electronic medical records and pagers were associated with cognitive complexity, and strained relationships between clinicians and rigid hierarchies were associated with social complexity. CONCLUSIONS: Communication is contextual, and improving physician-nurse communication about appropriate catheter use may require innovations that address the identified contextual barriers.


Asunto(s)
Centros Médicos Académicos/organización & administración , Cateterismo/enfermería , Barreras de Comunicación , Relaciones Médico-Enfermero , Centros Médicos Académicos/normas , Actitud del Personal de Salud , Cateterismo/normas , Catéteres de Permanencia , Registros Electrónicos de Salud/organización & administración , Humanos , Relaciones Interpersonales , Entrevistas como Asunto , Guías de Práctica Clínica como Asunto , Flujo de Trabajo
17.
World J Emerg Surg ; 14: 35, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31346347

RESUMEN

Background: Resuscitative endovascular balloon occlusion of the aorta (REBOA) for patients with traumatic torso hemorrhagic shock is available to keep a minimum level of circulatory status as a bridge to definitive therapy. However, the trajectory for placement of REBOA in the aorta has not yet been clearly defined. Methods: We conducted a retrospective observational cohort study in the two tertiary critical care and emergency center from December 2014 to October 2018. A total of 28 patients who underwent focused assessment with sonography for trauma (FAST) were studied via contrast computed tomography (CT), and 27 were analyzed. Results: We divided patients into two groups based on our CT findings. The REBOA deflate group included 16 patients, and the inflate group included 11 patients. The median trace value (interquartile range) of the blood vessel center line from the common femoral artery to the tip of REBOA (blood vessel length) and the length of REBOA itself from the common femoral artery to the tip of REBOA (REBOA insertion length) were 56.2 cm (54.5-57.2) and 55.2 cm (54.2-55.6), respectively (p < 0.0001) for the deflated group, and 51.4 cm (42.1-56.6) and 50.3 cm (42.3-55.0) (p = 0.594), respectively, for the inflated group. Conclusions: If REBOA was deflated, it was placed 1.0 cm longer than the insertion length of REBOA catheter itself, but that was not the case when inflating REBOA. The individual difference was large to the extent that the balloon inflated and the extent to which the balloon was pushed back toward the caudal depending on the degree of blood pressure. Further studies would be needed to validate the study findings.


Asunto(s)
Puntos Anatómicos de Referencia , Aorta/anatomía & histología , Oclusión con Balón/métodos , Cateterismo/métodos , Adulto , Oclusión con Balón/normas , Cateterismo/normas , Estudios de Cohortes , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/normas , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Resucitación/métodos , Resucitación/normas , Estudios Retrospectivos
18.
Curr Opin Anaesthesiol ; 32(3): 263-267, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30985339

RESUMEN

PURPOSE OF REVIEW: As the application of a test dose after epidural catheter insertion in obstetrics has recurrently been associated with serious adverse events affecting both maternal and foetal outcomes, the question whether to test or not remains a controversial issue. RECENT FINDINGS: Present guidelines do not provide clear recommendations in this regard and several recent surveys indicate a heterogeneity in clinical routine. SUMMARY: Physiological alterations during pregnancy and labour restrict the use and also the validity of traditional test agents. Epinephrine is not appropriate to detect a vascular insertion in labour and the application of a local anaesthetic test dose may lead to dose-dependent fatal consequences should the catheter be intrathecal, due to an increased sensitivity in parturients. Given the current practice of opioid-amended-low-concentration epidurals, the waiving of a test dose results at worst in a failed epidural, a stark contrast to the potentially severe to fatal complications of a 'traditional' test dose. Hence, an originally preventive measure providing potentially more harm than the consequences of the situation aimed to prevent, should not be recommended. A simple fractionated administration of the initial analgesic dose seems reasonable though.


Asunto(s)
Analgesia Epidural/métodos , Analgesia Obstétrica/métodos , Anestésicos Locales/administración & dosificación , Cateterismo/métodos , Epinefrina/administración & dosificación , Analgesia Epidural/efectos adversos , Analgesia Epidural/instrumentación , Analgesia Epidural/normas , Analgesia Obstétrica/efectos adversos , Analgesia Obstétrica/instrumentación , Analgesia Obstétrica/normas , Anestésicos Locales/efectos adversos , Cateterismo/efectos adversos , Cateterismo/instrumentación , Cateterismo/normas , Catéteres/efectos adversos , Relación Dosis-Respuesta a Droga , Espacio Epidural , Epinefrina/efectos adversos , Femenino , Humanos , Inyecciones Epidurales/efectos adversos , Inyecciones Epidurales/instrumentación , Inyecciones Epidurales/métodos , Inyecciones Epidurales/normas , Guías de Práctica Clínica como Asunto , Embarazo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...