Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Anal Bioanal Chem ; 409(17): 4157-4166, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28516278

RESUMEN

Although stir bar sportive extraction was thought to be a highly efficiency and simple pretreatment approach, its wide application was limited by low selectivity, short service life, and relatively high cost. In order to improve the performance of the stir bar, molecular imprinted polymers and magnetic carbon nanotubes were combined in the present study. In addition, two monomers were utilized to intensify the selectivity of molecularly imprinted polymers. Fourier transform infrared spectroscopy, scanning electron microscopy, and selectivity experiments showed that the molecularly imprinted polymeric stir bar was successfully prepared. Then micro-extraction based on the obtained stir bar was coupled with HPLC for determination of trace cefaclor and cefalexin in environmental water. This approach had the advantages of stir bar sportive extraction, high selectivity of molecular imprinted polymers, and high sorption efficiency of carbon nanotubes. To utilize this pretreatment approach, pH, extraction time, stirring speed, elution solvent, and elution time were optimized. The LOD and LOQ of cefaclor were found to be 3.5 ng · mL-1 and 12.0 ng · mL-1, respectively; the LOD and LOQ of cefalexin were found to be 3.0 ng · mL-1 and 10.0 ng · mL-1, respectively. The recoveries of cefaclor and cefalexin were 86.5 ~ 98.6%. The within-run precision and between-run precision were acceptable (relative standard deviation <7%). Even when utilized in more than 14 cycles, the performance of the stir bar did not decrease dramatically. This demonstrated that the molecularly imprinted polymeric stir bar based micro-extraction was a convenient, efficient, low-cost, and a specific method for enrichment of cefaclor and cefalexin in environmental samples.


Asunto(s)
Antibacterianos/análisis , Cefaclor/análisis , Cefalexina/análisis , Monitoreo del Ambiente/métodos , Impresión Molecular/métodos , Microextracción en Fase Sólida/métodos , Contaminantes Químicos del Agua/análisis , Adsorción , Antibacterianos/aislamiento & purificación , Cefaclor/aislamiento & purificación , Cefalexina/aislamiento & purificación , Cromatografía Líquida de Alta Presión/métodos , Lagos/análisis , Nanotubos de Carbono/química , Polímeros/química , Agua/análisis , Contaminantes Químicos del Agua/aislamiento & purificación
2.
J Pharm Sci ; 82(6): 622-6, 1993 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-8331538

RESUMEN

The acidic aqueous degradation of cefaclor, an orally administered cephalosporin antibiotic, has been investigated. The most prominent peak in the high-performance liquid chromatography profile of a degraded solution of cefaclor was isolated by preparative high-performance liquid chromatography. Mechanistically, the formation of this degradent from cefaclor involves a condensation of two cefaclor degradation products in which both products have undergone contraction from a six-membered cephem ring to a five-membered thiazole ring, presumably via a common episulfonium ion intermediate.


Asunto(s)
Cefaclor/química , Cefaclor/aislamiento & purificación , Cromatografía Líquida de Alta Presión , Ácido Clorhídrico , Espectroscopía de Resonancia Magnética , Espectrometría de Masa Bombardeada por Átomos Veloces , Espectrofotometría Infrarroja , Espectrofotometría Ultravioleta
3.
J Chromatogr ; 564(1): 195-203, 1991 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-1860913

RESUMEN

The separation of five amino beta-lactam antibiotics by reversed-phase high-performance liquid chromatography was studied as an insight into their retention behaviour. These five amphoteric compounds are cephradine, cephalexine, cefaclor, ampicillin and amoxicillin. Both octadecylsilane-bonded silica (C18) columns and phenyl-bonded silica (phenyl) columns were used, with mobile phase pH values between 2.5 and 7.4. In the absence of ion-pairing reagents the retention times for all the five compounds were the shortest at pH 4-6. The phenyl column was found to improve the separation between cephradine and ampicillin at pH values lower than 3, when these two compounds appeared as fused peaks on the C18 on C18 columns, with mobile phases both with and without ion-pairing reagents, were compared. The addition of 0.005 or 0.02 M tetraethylammonium acetate to the mobile phase did not result in significant ion-pair formation, except at pH values higher than 5.5. A strong ion-pairing effect was obtained at pH values higher than 6 with 0.005 or 0.02 M tetrabutylammonium phosphate, and the retention was decreased at pH values lower than 4. On the other hand, 0.005 M heptanesulphonic acid exhibited an ion-pair retention effect at pH values lower than 5. The molecular structures and pK(a) values were used to account for the retention behaviour of these antibiotics in the various mobile phases.


Asunto(s)
Antibacterianos/aislamiento & purificación , Cromatografía Líquida de Alta Presión/métodos , Amoxicilina/aislamiento & purificación , Ampicilina/aislamiento & purificación , Cefaclor/aislamiento & purificación , Cefalexina/aislamiento & purificación , Cefradina/aislamiento & purificación , Concentración de Iones de Hidrógeno , Tetraetilamonio , Compuestos de Tetraetilamonio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...