Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20.922
Filtrar
2.
J Plast Surg Hand Surg ; 59: 46-52, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747532

RESUMEN

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas Mal Unidas , Osteotomía , Fracturas del Radio , Humanos , Femenino , Osteotomía/métodos , Osteotomía/instrumentación , Persona de Mediana Edad , Fracturas del Radio/cirugía , Fracturas del Radio/diagnóstico por imagen , Anciano , Fracturas Mal Unidas/cirugía , Fracturas Mal Unidas/diagnóstico por imagen , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Impresión Tridimensional , Cirugía Asistida por Computador , Imagenología Tridimensional , Tornillos Óseos , Tomografía Computarizada por Rayos X
3.
BMC Oral Health ; 24(1): 550, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38734597

RESUMEN

BACKGROUND: Large cross-arch free-end surgical guides can obscure the visual field, compromising surgical accuracy due to insufficient stability at the free-end. This in vitro study aims to evaluate the accuracy of novel digital non-cross-arch surgical guides designed for implant placement at the mandibular free-end, incorporating tooth undercut retention and screw-bone support. MATERIALS AND METHODS: A mandibular dental model lacking left molars was utilized to fabricate unilateral (cross-arch) tooth-supported surgical guides (GT I, n = 20). Subsequently, two additional types of surgical guides were fabricated: GT II (covering two teeth, n = 20) and GT III (covering three teeth, n = 20). These novel surgical guides were designed to utilize the undercut of the supporting teeth for retention and enhance stability with screw-bone support at the guide's free-end. Furthermore, 60 identical guiding blocks were assembled on the three types of surgical guides to facilitate the implants' insertion. On a phantom head, 120 implant replicas were placed at the Federal Dentaire Internationale (FDI) teeth positions #36 and #37 on the dental model, employing a combination of surgical guides and guiding blocks. To assess accuracy, planned and placed implant positions were compared using intraoral optical scanning. Discrepancies in angulation and linear deviations, including the coronal/apical 3D deviations, lateral deviation as well as depth deviation, were measured. Statistical analysis was performed using two-way ANOVA and Bonferroni test (α = 0.05). RESULTS: GT I exhibited significantly largest discrepancies, including angular and linear deviations at the crest and apex at every implant site. Especially in depth, at implant site #36, the mean deviation value of GT I (0.27 ± 0.13 mm) was twice as large as GT III (0.13 ± 0.07 mm), and almost twice as large as GT II (0.14 ± 0.08 mm). However, at implant site #37, this deviation increased to almost a five-fold relationship between GT I (0.63 ± 0.12 mm) and II (0.14 ± 0.09 mm), as well as between GT I and III (0.13 ± 0.09 mm). No significant discrepancies existed between the novel surgical guides at either implant site #36 or #37. CONCLUSION: This study provides a practical protocol for enhancing accuracy of implant placement and reducing the size of free-end surgical guides used at mandibular molar sites.


Asunto(s)
Tornillos Óseos , Mandíbula , Modelos Dentales , Cirugía Asistida por Computador , Humanos , Mandíbula/cirugía , Cirugía Asistida por Computador/métodos , Implantación Dental Endoósea/métodos , Diseño Asistido por Computadora , Técnicas In Vitro
5.
Int J Med Robot ; 20(3): e2634, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38767083

RESUMEN

BACKGROUND: Reducing the annotation burden is an active and meaningful area of artificial intelligence (AI) research. METHODS: Multiple datasets for the segmentation of two landmarks were constructed based on 41 257 labelled images and 6 different microsurgical scenarios. These datasets were trained using the multi-stage transfer learning (TL) methodology. RESULTS: The multi-stage TL enhanced segmentation performance over baseline (mIOU 0.6892 vs. 0.8869). Besides, Convolutional Neural Networks (CNNs) achieved a robust performance (mIOU 0.8917 vs. 0.8603) even when the training dataset size was reduced from 90% (30 078 images) to 10% (3342 images). When directly applying the weight from one certain surgical scenario to recognise the same target in images of other scenarios without training, CNNs still obtained an optimal mIOU of 0.6190 ± 0.0789. CONCLUSIONS: Model performance can be improved with TL in datasets with reduced size and increased complexity. It is feasible for data-based domain adaptation among different microsurgical fields.


Asunto(s)
Microcirugia , Redes Neurales de la Computación , Humanos , Microcirugia/métodos , Inteligencia Artificial , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Procedimientos Quirúrgicos Otorrinolaringológicos/métodos , Aprendizaje Automático , Cirugía Asistida por Computador/métodos , Puntos Anatómicos de Referencia
6.
J Med Invest ; 71(1.2): 174-176, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38735716

RESUMEN

BACKGROUND: Augmented reality navigation is the one of the navigation technologies that allows computer-generated virtual images to be projected onto a real-world environment. Augmented reality navigation can be used in spinal tumor surgery. However, it is unknown if there are any pitfalls when using this technique. CASE PRESENTATION: The patient in this report underwent complete resection of a cauda equina tumor at the L2-L3 level using microscope-based augmented reality navigation. Although the registration error of navigation was <1 mm, we found a discrepancy between the augmented reality navigation images and the actual location of the tumor, which we have called "navigation mismatch". This mismatch, which was caused by the mobility of the spinal tumor in the dura mater, seems to be one of the pitfalls of augmented reality navigation for spinal tumors. CONCLUSIONS: Combined use of intraoperative ultrasound and augmented reality navigation seems advisable in such cases. J. Med. Invest. 71 : 174-176, February, 2024.


Asunto(s)
Realidad Aumentada , Cauda Equina , Humanos , Cauda Equina/diagnóstico por imagen , Cauda Equina/cirugía , Neoplasias del Sistema Nervioso Periférico/cirugía , Neoplasias del Sistema Nervioso Periférico/diagnóstico por imagen , Cirugía Asistida por Computador/métodos , Masculino , Femenino , Persona de Mediana Edad
7.
J Robot Surg ; 18(1): 209, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38727915

RESUMEN

This study aimed to report our experience in indocyanine green (ICG) fluorescence-guided surgery (FGS) in pediatric robotics. The data of 55 patients (35 boys and 20 girls), who underwent robotic surgery using ICG fluorescence in three institutions over the last 7 years, were retrospectively reviewed. The following robotic procedures were included: pyeloplasty (n = 21), complex Lich-Gregoir ureteral reimplantation (n = 8), varicocelectomy (n = 7), adnexal pathology resection (n = 8), partial nephrectomy (n = 4), nephrectomy (n = 4), renal cyst removal (n = 2), and excision of prostatic utricle (n = 1). The ICG was injected intravenously in all indications except for varicocele where intratesticular injection was done, and prostatic utricle or paraureteral diverticulum where trans-catheter injection was done. The ICG dosage was 0.2-0.3 mg/mL/kg. All the procedures were performed using da Vinci Xi platform. Firefly® allowed to switch form bright light to ICG-NIRF view and vice versa. All the procedures were accomplished in robotics without conversions to laparoscopy or open surgery. No episodes of allergy or anaphylaxis to ICG were recorded. An excellent ICG-NIRF view of target organs was obtained in all procedures. Based on our experience, we believe that application of ICG FGS in pediatric robotics enhances the identification of critical anatomical elements and pathological structures, thereby positively impacting both oncological and functional outcomes. This technique is safe, feasible, and versatile. We advocate the consideration of ICG as the standard of care in certain procedures such as partial nephrectomy, varicocele repair, tumor resection, and ovarian torsion. Nonetheless, further investigations are warranted to explore its potential broader applications in pediatric urology.


Asunto(s)
Verde de Indocianina , Procedimientos Quirúrgicos Robotizados , Humanos , Verde de Indocianina/administración & dosificación , Procedimientos Quirúrgicos Robotizados/métodos , Femenino , Masculino , Niño , Estudios Retrospectivos , Preescolar , Adolescente , Lactante , Fluorescencia , Nefrectomía/métodos , Cirugía Asistida por Computador/métodos
8.
Clin Oral Investig ; 28(6): 325, 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38762665

RESUMEN

OBJECTIVE: With the increasing maturity of 3D printing technology, the application of digital guide template in the extraction of impacted teeth has become more sophisticated. However, for maxillary palatal deeply impacted teeth, there still exist significant clinical challenges. This experiment introduces a novel digital guide template and innovatively employs a flapless technique to explore a minimally invasive approach for the extraction of palatal deeply impacted teeth. METHODS: This experiment included 40 patients diagnosed with palatal completely impacted teeth, randomly divided into an experimental group and a control group. The experimental group used the new digital guide template for flapless extraction, while the control group employed the traditional freehand flap technique. RESULTS: The experimental group can significantly reduce the localization time of palatally impacted teeth (P < 0.001), with total surgery times of 18.15 ± 4.88 min and 22.00 ± 7.71 min for the experimental and control groups, respectively (P = 0.067). Although there were no significant statistical differences between the two groups in terms of intraoperative bleeding, adjacent tooth damage, infection, or damage to nearby important anatomical structures, the experimental group showed significant improvements in postoperative pain (P < 0.05), swelling (P < 0.001), and patient satisfaction (P < 0.001) compared to the control group. CONCLUSION: Compared to traditional freehand flap surgery, flapless extraction of palatally impacted teeth guided by digital templates significantly reduces the localization time of impacted teeth and demonstrates notable advantages in some postoperative complications. Future studies with larger sample sizes are needed to substantiate the feasibility of this technique.


Asunto(s)
Estudios de Factibilidad , Extracción Dental , Diente Impactado , Adolescente , Adulto , Femenino , Humanos , Masculino , Maxilar/cirugía , Satisfacción del Paciente , Impresión Tridimensional , Cirugía Asistida por Computador/métodos , Extracción Dental/métodos , Diente Impactado/cirugía , Resultado del Tratamiento
9.
BMC Musculoskelet Disord ; 25(1): 396, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38773483

RESUMEN

PURPOSE: This systematic review aims to provide an overview of the current knowledge on the role of the metaverse, augmented reality, and virtual reality in reverse shoulder arthroplasty. METHODS: A systematic review was performed using the PRISMA guidelines. A comprehensive review of the applications of the metaverse, augmented reality, and virtual reality in in-vivo intraoperative navigation, in the training of orthopedic residents, and in the latest innovations proposed in ex-vivo studies was conducted. RESULTS: A total of 22 articles were included in the review. Data on navigated shoulder arthroplasty was extracted from 14 articles: seven hundred ninety-three patients treated with intraoperative navigated rTSA or aTSA were included. Also, three randomized control trials (RCTs) reported outcomes on a total of fifty-three orthopedics surgical residents and doctors receiving VR-based training for rTSA, which were also included in the review. Three studies reporting the latest VR and AR-based rTSA applications and two proof of concept studies were also included in the review. CONCLUSIONS: The metaverse, augmented reality, and virtual reality present immense potential for the future of orthopedic surgery. As these technologies advance, it is crucial to conduct additional research, foster development, and seamlessly integrate them into surgical education to fully harness their capabilities and transform the field. This evolution promises enhanced accuracy, expanded training opportunities, and improved surgical planning capabilities.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Realidad Aumentada , Realidad Virtual , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Cirugía Asistida por Computador/educación , Cirugía Asistida por Computador/métodos , Articulación del Hombro/cirugía
10.
Theranostics ; 14(7): 2736-2756, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38773975

RESUMEN

Radical prostatectomy (RP) combined with pelvic lymph node dissection (PLND) is the first step in multimodal treatment of prostate cancer (PCa) without distant metastases. For a long time, the surgical resection range has been highly dependent on the surgeon's visualization and experience with preoperative imaging. With the rapid development of prostate-specific membrane antigen positron emission tomography and single-photon emission computed tomography (PSMA-PET and PSMA-SPECT), PSMA-targeted surgery has been introduced for a more accurate pathological diagnosis and complete resection of positive surgical margins (PSMs) and micro-lymph node metastases (LNMs). We reviewed PSMA-targeted surgeries, including PSMA-PET-guided prostatic biopsy (PSMA-TB), PSMA-targeted radio-guided surgery (PSMA-RGS), PSMA-targeted fluorescence-guided surgery (PSMA-FGS), and multi-modality/multi-targeted PSMA-targeted surgery. We also discuss the strengths and challenges of PSMA-targeted surgery, and propose that PSMA-targeted surgery could be a great addition to existing surgery protocols, thereby improving the accuracy and convenience of surgery for primary and recurrent PCa in the near future.


Asunto(s)
Antígenos de Superficie , Glutamato Carboxipeptidasa II , Prostatectomía , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico , Neoplasias de la Próstata/patología , Glutamato Carboxipeptidasa II/metabolismo , Antígenos de Superficie/metabolismo , Prostatectomía/métodos , Cirugía Asistida por Computador/métodos , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Escisión del Ganglio Linfático/métodos
11.
Nano Lett ; 24(20): 6131-6138, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38727077

RESUMEN

Accurate intraoperative tumor delineation is critical to achieving successful surgical outcomes. However, conventional techniques typically suffer from poor specificity and low sensitivity and are time-consuming, which greatly affects intraoperative decision-making. Here, we report a cascade activatable near-infrared fluorescent (NIRF) probe IR780SS@CaP that can sequentially respond to tumor acidity and elevated glutathione levels for accurate intraoperative tumor localization. Compared with nonactivatable and single-factor activatable probes, IR780SS@CaP with a cascade strategy can minimize nonspecific activation and false positive signals in a complicated biological environment, affording a superior tumor-to-normal tissue ratio to facilitate the delineation of abdominal metastases. Small metastatic lesions that were less than 1 mm in diameter can be precisely identified by IR780SS@CaP and completely excised under NIRF imaging guidance. This study could benefit tumor diagnosis and image-guided tumor surgery by providing real-time information and reliable decision support, thus reducing the risk of both recurrence and complications to improve patient outcomes.


Asunto(s)
Colorantes Fluorescentes , Colorantes Fluorescentes/química , Humanos , Animales , Ratones , Imagen Óptica/métodos , Línea Celular Tumoral , Neoplasias/diagnóstico por imagen , Neoplasias/patología , Cirugía Asistida por Computador/métodos , Espectroscopía Infrarroja Corta/métodos
12.
Head Face Med ; 20(1): 30, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745297

RESUMEN

BACKGROUND: Computer-guided implant surgery has improved the quality of implant treatment by facilitating the placement of implants in a more accurate manner. This study aimed to assess the accuracy of implant placement in a clinical setting using three techniques: dynamic navigation, static surgical guides, and freehand placement. We also investigated potential factors influencing accuracy to provide a comprehensive evaluation of each technique's advantages and disadvantages. MATERIALS AND METHODS: Ninety-four implants in 65 patients were included in this prospective study. Patients were randomly assigned to one of three groups: dynamic navigation, static surgical guides, or freehand placement. Implants were placed using a prosthetically oriented digital implant planning approach, and postoperative CBCT scans were superimposed on preoperative plans to measure accuracy. Seven deviation values were calculated, including angular, platform, and apical deviations. Demographic and consistency analyses were performed, along with one-way ANOVA and post-hoc tests for deviation values. RESULTS: The mean global platform, global apical, and angular deviations were 0.99 mm (SD 0.52), 1.14 mm (SD 0.56), and 3.66° (SD 1.64°) for the dynamic navigation group; 0.92 mm (SD 0.36), 1.06 mm (SD 0.47), and 2.52° (SD 1.18°) for the surgical guide group; and 1.36 mm (SD 0.62), 1.73 mm (SD 0.66), and 5.82° (SD 2.79°) for the freehand group. Both the dynamic navigation and surgical guide groups exhibited statistically significant differences in all values except depth deviations compared to the freehand group (p < 0.05), whereas only the angular deviation showed a significant difference between the dynamic navigation and surgical guide groups (p = 0.002). CONCLUSION: Our findings highlight the superior accuracy and consistency of dynamic navigation and static surgical guides compared to freehand placement in implant surgery. Dynamic navigation offers precision and flexibility. However, it comes with cost and convenience considerations. Future research should focus on improving its practicality. TRIAL REGISTRATION: This study was retrospectively registered at the Thai Clinical Trials Register-Medical Research Foundation of Thailand (MRF) with the TCTR identification number TCTR20230804001 on 04/08/2023. It was also conducted in accordance with the Declaration of Helsinki and approved by the institutional ethics committee at the Xian Jiaotong University Hospital of Stomatology, Xian, China (xjkqII[2021] No: 043). Written informed consent was obtained from all participants.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea , Cirugía Asistida por Computador , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada de Haz Cónico/métodos , Implantación Dental Endoósea/métodos , Estudios Prospectivos , Cirugía Asistida por Computador/métodos
13.
JAMA Netw Open ; 7(5): e2411384, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38748422

RESUMEN

Importance: Hypoparathyroidism following thyroid surgery is a serious complication that occurs frequently when surgery is performed by low-volume thyroid surgeons without experience in parathyroid surgery. Objective: To evaluate the occurrence of hypoparathyroidism following total thyroidectomy after the introduction of autofluorescence in low-volume, nonparathyroid institutions. Design, Setting, and Participants: This prospective, multicenter cohort study, with a follow-up period of up to 1 year, was conducted in Denmark at 2 low-volume nonparathyroid institutions between January 2021 and November 2023. All adult patients referred for total thyroidectomy were assessed for eligibility (n = 90). Only patients with no history of thyroid surgery were considered (n = 89). Patients who only underwent lobectomy (n = 6) or declined to participate (n = 5) were excluded. All included patients completed follow-up. The prospective cohort was compared with a historical cohort of successive patients undergoing primary total thyroidectomy from 2016 to 2020 (before autofluorescence was available). Intervention: Included patients underwent autofluorescence-guided total thyroidectomy. Main outcomes and Measures: Rate of hypoparathyroidism. Immediate hypoparathyroidism was defined as the need for active vitamin D postoperatively, whereas permanent hypoparathyroidism was considered when there still was a need for active vitamin D 1 year after surgery. Results: Seventy-eight patients underwent autofluorescence-guided surgery (mean [SD] age, 55.6 [13.1] years; 67 [86%] female) and were compared with 89 patients in the historical cohort (mean [SD] age, 49.7 [12.8] years; 78 [88%] female). The rate of immediate hypoparathyroidism decreased from 37% (95% CI, 27%-48%) to 19% (95% CI, 11%-30%) after the introduction of autofluorescence (P = .02). Permanent hypoparathyroidism rates decreased from 32% (95% CI, 22%-42%) to 6% (95% CI, 2%-14%) (P < .001), reaching 0% at the end of the study. More parathyroid glands were identified with autofluorescence (75% [95% CI, 70%-80%] vs 61% [95% CI, 56%-66%]) (P < .001) and less parathyroid glands were inadvertently excised (4% [95% CI, 1%-11%] vs 21% [95% CI, 13%-31%]) (P = .001). Conclusions and Relevance: In this cohort study of autofluorescence-guided thyroid surgery in low-volume, nonparathyroid institutions, the use of autofluorescence was associated with a significant decrease in both immediate and permanent hypoparathyroidism. When autofluorescence was used, hypoparathyroidism rates were comparable with those of high-volume surgeons who also perform parathyroid surgery.


Asunto(s)
Hipoparatiroidismo , Complicaciones Posoperatorias , Tiroidectomía , Humanos , Tiroidectomía/efectos adversos , Tiroidectomía/métodos , Hipoparatiroidismo/etiología , Hipoparatiroidismo/epidemiología , Femenino , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Adulto , Dinamarca/epidemiología , Imagen Óptica/métodos , Anciano , Cirugía Asistida por Computador/métodos , Cirugía Asistida por Computador/efectos adversos
14.
Braz J Cardiovasc Surg ; 39(4): e20230237, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748975

RESUMEN

Transcatheter mitral valve-in-valve is an alternative to high-risk reoperation on a failing bioprosthesis. It entails specific challenges such as left ventricular outflow tract obstruction. We propose a patient-specific augmented imaging based on preoperative planning to assist the procedure. Valve-in-valve simulation was performed to represent the optimal level of implantation and the neo-left ventricular outflow tract. These data were combined with intraoperative images through a real-time 3D/2D registration tool. All data were collected retrospectively on one case (pre and per-procedure imaging). We present for the first time an intraoperative guidance tool in transcatheter mitral valve-in-valve procedure.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Mitral , Cirugía Asistida por Computador , Humanos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Cirugía Asistida por Computador/métodos , Cateterismo Cardíaco/métodos , Bioprótesis , Estudios Retrospectivos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Femenino , Masculino
16.
J Refract Surg ; 40(5): e336-e343, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717081

RESUMEN

PURPOSE: To assess and compare the visual acuity and refractive outcomes of topography-guided laser in situ keratomileusis (LASIK) based on the fitting-shape-based refractive compensated and Phorcides software strategies. METHODS: Consecutive patients who underwent topography-guided LASIK were included in this study. Through double-masked simple randomization, patients were assigned to the Zhang & Zheng Auto-compensate Refraction (ZZ AR) group (the fitting-shape-based refractive compensated strategy using the ZZ AR calculator was used) or the Phorcides group (the topography analysis algorithm in Phorcides software [Phorcides LLC] was used). Only one eye per patient with binocular correction was randomly enrolled. The preoperative and postoperative visual acuities and refraction were analyzed at the 6-month follow-up visit. RESULTS: The ZZ AR and Phorcides groups comprised 156 and 147 eyes, respectively. At the 6-month postoperative follow-up visit, the median (range) absolute residual cylindrical refraction was 0.35 (1.01) and 0.47 (1.63) diopters (D) for the ZZ AR and Phorcides groups, respectively (P < .001). The percentages of patients with residual cylindrical power within 0.25 D were 29.49% and 13.61% for the ZZ AR and Phorcides groups, respectively (P = .001). Based on the percentages of patients with residual cylindrical powers within 0.50 and 1.00 D, the ZZ AR group showed better outcomes (P = .02 and .01). The percentage of patients with visual acuity better than 20/16 was significantly higher for the ZZ AR group than for the Phorcides group (P = .03). CONCLUSIONS: The fitting-shape-based refractive compensated strategy for topography-guided LASIK procedures can better optimize the visual acuity and astigmatic refraction than the Phorcides software strategy. [J Refract Surg. 2024;40(5):e336-e343.].


Asunto(s)
Topografía de la Córnea , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Refracción Ocular , Cirugía Asistida por Computador , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Agudeza Visual/fisiología , Estudios Prospectivos , Refracción Ocular/fisiología , Adulto , Masculino , Femenino , Láseres de Excímeros/uso terapéutico , Método Doble Ciego , Miopía/cirugía , Miopía/fisiopatología , Adulto Joven , Cirugía Asistida por Computador/métodos , Persona de Mediana Edad , Córnea/cirugía , Córnea/fisiopatología , Estudios de Seguimiento
17.
J Nanobiotechnology ; 22(1): 224, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702709

RESUMEN

Poorly identified tumor boundaries and nontargeted therapies lead to the high recurrence rates and poor quality of life of prostate cancer patients. Near-infrared-II (NIR-II) fluorescence imaging provides certain advantages, including high resolution and the sensitive detection of tumor boundaries. Herein, a cyanine agent (CY7-4) with significantly greater tumor affinity and blood circulation time than indocyanine green was screened. By binding albumin, the absorbance of CY7-4 in an aqueous solution showed no effects from aggregation, with a peak absorbance at 830 nm and a strong fluorescence emission tail beyond 1000 nm. Due to its extended circulation time (half-life of 2.5 h) and high affinity for tumor cells, this fluorophore was used for primary and metastatic tumor diagnosis and continuous monitoring. Moreover, a high tumor signal-to-noise ratio (up to ~ 10) and excellent preferential mitochondrial accumulation ensured the efficacy of this molecule for photothermal therapy. Therefore, we integrated NIR-II fluorescence-guided surgery and intraoperative photothermal therapy to overcome the shortcomings of a single treatment modality. A significant reduction in recurrence and an improved survival rate were observed, indicating that the concept of intraoperative combination therapy has potential for the precise clinical treatment of prostate cancer.


Asunto(s)
Carbocianinas , Mitocondrias , Recurrencia Local de Neoplasia , Terapia Fototérmica , Neoplasias de la Próstata , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Terapia Fototérmica/métodos , Humanos , Animales , Mitocondrias/metabolismo , Mitocondrias/efectos de los fármacos , Línea Celular Tumoral , Carbocianinas/química , Imagen Óptica/métodos , Ratones , Cirugía Asistida por Computador/métodos , Colorantes Fluorescentes/química , Ratones Desnudos , Ratones Endogámicos BALB C , Rayos Infrarrojos , Verde de Indocianina/química , Verde de Indocianina/uso terapéutico , Verde de Indocianina/farmacología
18.
Acta Neurochir (Wien) ; 166(1): 212, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38739282

RESUMEN

PURPOSE: Glioblastoma is a malignant and aggressive brain tumour that, although there have been improvements in the first line treatment, there is still no consensus regarding the best standard of care (SOC) upon its inevitable recurrence. There are novel adjuvant therapies that aim to improve local disease control. Nowadays, the association of intraoperative photodynamic therapy (PDT) immediately after a 5-aminolevulinic acid (5-ALA) fluorescence-guided resection (FGR) in malignant gliomas surgery has emerged as a potential and feasible strategy to increase the extent of safe resection and destroy residual tumour in the surgical cavity borders, respectively. OBJECTIVES: To assess the survival rates and safety of the association of intraoperative PDT with 5-ALA FGR, in comparison with a 5-ALA FGR alone, in patients with recurrent glioblastoma. METHODS: This article describes a matched-pair cohort study with two groups of patients submitted to 5-ALA FGR for recurrent glioblastoma. Group 1 was a prospective series of 11 consecutive cases submitted to 5-ALA FGR plus intraoperative PDT; group 2 was a historical series of 11 consecutive cases submitted to 5-ALA FGR alone. Age, sex, Karnofsky performance scale (KPS), 5-ALA post-resection status, T1-contrast-enhanced extent of resection (EOR), previous and post pathology, IDH (Isocitrate dehydrogenase), Ki67, previous and post treatment, brain magnetic resonance imaging (MRI) controls and surgical complications were documented. RESULTS: The Mantel-Cox test showed a significant difference between the survival rates (p = 0.008) of both groups. 4 postoperative complications occurred (36.6%) in each group. As of the last follow-up (January 2024), 7/11 patients in group 1, and 0/11 patients in group 2 were still alive. 6- and 12-months post-treatment, a survival proportion of 71,59% and 57,27% is expected in group 1, versus 45,45% and 9,09% in group 2, respectively. 6 months post-treatment, a progression free survival (PFS) of 61,36% and 18,18% is expected in group 1 and group 2, respectively. CONCLUSION: The association of PDT immediately after 5-ALA FGR for recurrent malignant glioma seems to be associated with better survival without additional or severe morbidity. Despite the need for larger, randomized series, the proposed treatment is a feasible and safe addition to the reoperation.


Asunto(s)
Ácido Aminolevulínico , Neoplasias Encefálicas , Glioblastoma , Recurrencia Local de Neoplasia , Fotoquimioterapia , Cirugía Asistida por Computador , Humanos , Glioblastoma/cirugía , Glioblastoma/tratamiento farmacológico , Glioblastoma/diagnóstico por imagen , Ácido Aminolevulínico/uso terapéutico , Masculino , Neoplasias Encefálicas/cirugía , Neoplasias Encefálicas/tratamiento farmacológico , Neoplasias Encefálicas/diagnóstico por imagen , Femenino , Persona de Mediana Edad , Fotoquimioterapia/métodos , Recurrencia Local de Neoplasia/cirugía , Anciano , Estudios de Cohortes , Cirugía Asistida por Computador/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Adulto , Estudios Prospectivos , Procedimientos Neuroquirúrgicos/métodos
19.
BMC Oral Health ; 24(1): 582, 2024 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-38764019

RESUMEN

BACKGROUND: The operation accuracy and efficiency of dynamic navigated endodontic surgery were evaluated through in vitro experiments. This study provides a reference for future clinical application of dynamic navigation systems in endodontic surgery. MATERIALS AND METHODS: 3D-printed maxillary anterior teeth were used in the preparation of models for endodontic surgery. Endodontic surgery was performed with and without dynamic navigation by an operator who was proficient in dynamic navigation technology but had no experience in endodontic surgery. Optical scanning data were applied to evaluate the length and angle deviations of root-end resection. And the operation time was recorded. T tests were used to analyze the effect of dynamic navigation technology on the accuracy and duration of endodontic surgery. RESULTS: With dynamic navigation, the root-end resection length deviation was 0.46 ± 0.06 mm, the angle deviation was 2.45 ± 0.96°, and the operation time was 187 ± 22.97 s. Without dynamic navigation, the root-end resection length deviation was 1.20 ± 0.92 mm, the angle deviation was 16.20 ± 9.59°, and the operation time was 247 ± 61.47 s. Less deviation was achieved and less operation time was spent with than without dynamic navigation (P < 0.01). CONCLUSION: The application of a dynamic navigation system in endodontic surgery can improve the accuracy and efficiency significantly for operators without surgical experience and reduce the operation time.


Asunto(s)
Impresión Tridimensional , Humanos , Proyectos Piloto , Técnicas In Vitro , Cirugía Asistida por Computador/métodos , Apicectomía/métodos , Tempo Operativo , Sistemas de Navegación Quirúrgica
20.
J Med Chem ; 67(7): 5800-5812, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38560986

RESUMEN

Near-infrared (NIR) fluorescence imaging has attracted much attention in image-guided interventions with unique advantages. However, the clinical translation rate of fluorescence probes is extremely low, primarily due to weak lesion signal contrast and poor specificity. To address this dilemma, a series of small-molecule near-infrared fluorescence probes have been designed for tumor imaging. Among them, YQ-04-03 showed notable optical stability and remarkable sensitivity toward tumor targeting. Moreover, within a specific concentration and time range against oxidizing reducing agents and laser, it demonstrated better stability than ICG. The retention time of YQ-04-03 in tumors was significantly longer compared to other nonspecific uptake sites in the subjects, and its tumor-to-normal tissue ratio (TNR) outperformed ICG. Successful resection of in situ hepatocarcinoma and peritoneal carcinoma was achieved using probe imaging guidance, with the smallest visual lesion resected measuring approximately 1 mm3. Ultimately, this probe holds great potential for advancing tumor tracer.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Cirugía Asistida por Computador , Humanos , Colorantes Fluorescentes , Imagen Óptica/métodos , Cirugía Asistida por Computador/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA