1.
Biomed Chromatogr ; 38(8): e5925, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38837800

RESUMEN

The rapid and accurate detection of illegal adulteration of chemical drugs into dietary supplements is a big challenge in the food chemistry field. Detection of compounds without a standard reference is even more difficult; however, this is a common situation. Here in this study, a novel "standard-free detection of adulteration" (SFDA) method was proposed and phosphodiesterase-5 inhibitor derivatives were used as an example to figure out the possibility and reliability of this SFDA method. After analysis by quadrupole coupled time of flight-tandem mass spectrometry detection and multivariable statistics, six common fragment ions were chosen to indicate whether adulteration was present or not, while 20 characteristic fragment ions indicated whether adulteration was by nitrogen-containing heterocycles or by anilines. Furthermore, the quantitative methods were conducted by high-performance liquid chromatography-tandem mass spectrometry. In a word, this strategy allows for a quick determination of dietary supplement adulteration without any need for standard materials, improving the efficacy of food safety testing.


Asunto(s)
Suplementos Dietéticos , Contaminación de Medicamentos , Citrato de Sildenafil , Espectrometría de Masas en Tándem , Suplementos Dietéticos/análisis , Citrato de Sildenafil/análisis , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida de Alta Presión/métodos , Reproducibilidad de los Resultados , Límite de Detección , Modelos Lineales , Inhibidores de Fosfodiesterasa 5/análisis
2.
Molecules ; 29(9)2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38731577

RESUMEN

Recently, benchtop nuclear magnetic resonance (NMR) spectrometers utilizing permanent magnets have emerged as versatile tools with applications across various fields, including food and pharmaceuticals. Their efficacy is further enhanced when coupled with chemometric methods. This study presents an innovative approach to leveraging a compact benchtop NMR spectrometer coupled with chemometrics for screening honey-based food supplements adulterated with active pharmaceutical ingredients. Initially, fifty samples seized by French customs were analyzed using a 60 MHz benchtop spectrometer. The investigation unveiled the presence of tadalafil in 37 samples, sildenafil in 5 samples, and a combination of flibanserin with tadalafil in 1 sample. After conducting comprehensive qualitative and quantitative characterization of the samples, we propose a chemometric workflow to provide an efficient screening of honey samples using the NMR dataset. This pipeline, utilizing partial least squares discriminant analysis (PLS-DA) models, enables the classification of samples as either adulterated or non-adulterated, as well as the identification of the presence of tadalafil or sildenafil. Additionally, PLS regression models are employed to predict the quantitative content of these adulterants. Through blind analysis, this workflow allows for the detection and quantification of adulterants in these honey supplements.


Asunto(s)
Suplementos Dietéticos , Miel , Espectroscopía de Resonancia Magnética , Miel/análisis , Suplementos Dietéticos/análisis , Espectroscopía de Resonancia Magnética/métodos , Citrato de Sildenafil/análisis , Flujo de Trabajo , Quimiometría/métodos , Tadalafilo/análisis , Análisis de los Mínimos Cuadrados , Contaminación de Medicamentos/prevención & control , Análisis Discriminante
3.
Bioanalysis ; 16(9): 369-384, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38497721

RESUMEN

This study was conducted to compare dissolution profiles of four Jordanian registered sildenafil (SDF) products to the originator. Dissolution samples were analyzed utilizing a validated and stability-indicating HPLC method in human plasma. Validation was performed for specificity, linearity, limit of detection, lower limit of quantification, precision, trueness and stability. SDF was extracted from plasma samples using liquid-liquid extraction. The analysis was performed utilizing isocratic elution on C18 column with 1.0 ml/min flow rate. The regression value was ∼0.999 over 3 days with drug recovery between 86.6 to 89.8%with 10 ng/ml lower limit of quantitation. This method displayed a good selectivity of SDF with improved stability under various conditions. The method was used for SDF quantification in dissolution medium. Similarity factors for local products varied according to the used mediums, but all SDF local products passed the dissolution in vitro test since all of them showed a released of >85% after 60 min at the dissolution mediums.


[Box: see text].


Asunto(s)
Citrato de Sildenafil , Citrato de Sildenafil/sangre , Citrato de Sildenafil/química , Citrato de Sildenafil/análisis , Cromatografía Líquida de Alta Presión/métodos , Humanos , Medicamentos Genéricos/química , Medicamentos Genéricos/análisis , Solubilidad , Jordania , Estabilidad de Medicamentos , Límite de Detección
4.
Braz. J. Pharm. Sci. (Online) ; 58: e19491, 2022. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1383957

RESUMEN

Abstract The illicit market of counterfeit medicines containing sildenafil and tadalafil has been causing serious public health problems. Thus, further studies on this illicit association are needed. A stability-indicating HPLC method was developed for simultaneous determination of tadalafil (TAD) and sildenafil (SIL) using a C18 column (250 x 4.6 mm, 5 µm). Detection was achieved at 284 nm, for TAD, and 292 nm, for SIL. The method was considered to be specific, linear, precise, accurate, robust, and sensitive. In the photodegradation kinetic studies, the drugs showed a first-order reaction rate when isolated, and zero-order when associated. Toxicological assays demonstrated that the photodegraded drugs decreased cell viability in compared to non- degraded drugs, suggesting cytotoxic activity. Additional, mutagenic activity was not observed under the tested conditions. Photodegraded drugs, in association, depicted DNA damage index, suggesting genotoxic effects. The obtained results will be able to support the forensic intelligence laboratories, as well as to alert the population about the risk inherent to consuming counterfeit products.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Fotoblanqueo/efectos de los fármacos , Citrato de Sildenafil/análisis , Tadalafilo/análisis , Medicamentos Falsificados/clasificación
5.
Braz. J. Pharm. Sci. (Online) ; 53(1): e15181, 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-839459

RESUMEN

Sildenafil citrate (SILC) is a potent phosphodiesterase-5 inhibitor used for erectile dysfunction and pulmonary hypertension. This study shows two simple, fast and alternative analytical methods for SILC determination by non-aqueous titration and by derivative ultraviolet spectrophotometry (DUS) in active pharmaceutical ingredient and/or dosage forms. The quantitation method of SILC active pharmaceutical ingredient by non-aqueous acid-base titration was developed using methanol as solvent and 0.1 mol/L of perchloric acid in acetic acid as titrant. The endpoint was potentiometrically detected. The non-aqueous titration method shows satisfactory repeatability and intermediate precision (RSD 0.70-1.09%). The neutralization reaction occurred in the stoichiometric ratio 1:1 in methanol. The determination of SILC active pharmaceutical ingredient or dosage forms by DUS was developed in the linear range from 10 to 40 µg/mL, in 0.01 mol/L HCl, using the first order zero-peak method at λ 256 nm. The DUS method shows selectivity toward tablets excipients, appropriate linearity (R2 0.9996), trueness (recovery range 98.86-99.30%), repeatability and intermediate precision in three concentration levels (RSD 1.17-1.28%; 1.29-1.71%, respectively). Therefore, the methods developed are excellent alternatives to sophisticated instrumental methods and can be easily applied in any pharmaceutical laboratory routine due to simple and fast executions.


Asunto(s)
Espectrofotometría Ultravioleta/métodos , Volumetría/métodos , Citrato de Sildenafil/análisis , Comprimidos/farmacología , Vasodilatadores/clasificación