Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 707
Filtrar
1.
Anal Methods ; 16(24): 3867-3877, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38828675

RESUMEN

A Ti3C2Tx/MoS2/MWCNT@rGONR nanocomposite was prepared for the first time for building a sensitive electrochemical aptasening platform to simultaneously detect kanamycin (Kana) and chloramphenicol (Cap). Owing to their accordion-like structure, rich surface groups, and high charge mobility, Ti3C2Tx/MoS2/MWCNT@rGONR composites provided a spacious covalent immobilization surface and a better electrochemical aptasensing platform. The aptamers of Kana and Cap used in sensors enhance the selectivity. Furthermore, TiP, an ion exchanger, was used for loading more different metal ions functioning as labels to form a sandwich-type sensor together with Ti3C2Tx/MoS2/MWCNT@rGONR, improving the electrochemical sensitivity and obtaining a highly distinguishable signal readout. Under the optimized conditions, the sensor has good detection limits of 0.135 nmol L-1 and 0.173 nmol L-1 for Kana and Cap, respectively, at the same linearity concentration of 0.5-2500 nmol L-1. Finally, it was successfully applied for detection in milk and fish meat, and the results were compared with the standard method HPLC, indicating its great potential for food safety monitoring.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Cloranfenicol , Técnicas Electroquímicas , Contaminación de Alimentos , Kanamicina , Leche , Titanio , Cloranfenicol/análisis , Cloranfenicol/química , Kanamicina/análisis , Kanamicina/química , Técnicas Electroquímicas/métodos , Aptámeros de Nucleótidos/química , Titanio/química , Animales , Leche/química , Contaminación de Alimentos/análisis , Técnicas Biosensibles/métodos , Molibdeno/química , Límite de Detección , Nanotubos de Carbono/química , Grafito/química , Nanocompuestos/química , Análisis de los Alimentos/métodos , Antibacterianos/análisis , Antibacterianos/química , Peces , Disulfuros
2.
Food Chem ; 454: 139650, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38788478

RESUMEN

Inspired by the desert beetle, a novel biomimetic chip was developed to detect chloramphenicol (CP). The chip was characterized by a periodic array in which hydrophobic Au nanoparticles (AuNPs) were semi-embedded on hydrophilic polymethyl methacrylate (PMMA) spheres. Among them, the AuNPs exhibited both a localized surface plasmon resonance effect to amplify the reflected signal and a synergistic effect with PMMA spheres to create a significant hydrophilic-hydrophobic interface, which facilitated the enrichment of target CP molecules and improved sensitivity. After optimization, the chip showed direct, ultrasensitive (as low as 0.2 ng/mL), fast (5 min), and selective detection of CP with a wide concentration range extending from 0.2 ng/mL to 1000 ng/mL. During detection, color changes of the chip were observed by naked eyes without any color display equipment. The recovery of CP was between 94.65 % and 108.70 % in chicken and milk samples.


Asunto(s)
Pollos , Cloranfenicol , Escarabajos , Contaminación de Alimentos , Oro , Nanopartículas del Metal , Leche , Cloranfenicol/análisis , Cloranfenicol/química , Animales , Oro/química , Nanopartículas del Metal/química , Escarabajos/química , Contaminación de Alimentos/análisis , Leche/química , Antibacterianos/análisis , Antibacterianos/química , Coloides/química
3.
Food Chem ; 454: 139806, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38820635

RESUMEN

Misuse of chloramphenicol (CAP) can lead to severe food safety issues. Therefore, the accurate and sensitive detection of CAP residues is important for public health. Herein, a convenient and reliable interfacial self-assembly technique was used to form a uniform Au@Ag nanobipyramids (NBPs) film on an ordered SiO2 nanosphere array (SiO2 NS), which served as a Raman-enhanced substrate. In conjunction with a deoxyribonucleic acid enzyme-induced signal amplification strategy, we developed a novel surface-enhanced Raman scattering (SERS) biosensor for the selective and sensitive detection of CAP. The biosensor exhibited a detection limit of 6.42 × 10-13 mol·L-1 and a detection range of 1.0 × 10-12-1.0 × 10-6 mol·L-1. The biosensor could detect CAP in spiked milk samples with a high accuracy, and its recovery rates ranged from 97.88% to 107.86%. The as-developed biosensor with the advantages of high sensitivity and high selectivity offers a new strategy for the rapid, reliable and sensitive detection of CAP, rendering it applicable to food safety control.


Asunto(s)
Técnicas Biosensibles , Cloranfenicol , ADN Catalítico , Contaminación de Alimentos , Oro , Límite de Detección , Leche , Dióxido de Silicio , Plata , Espectrometría Raman , Dióxido de Silicio/química , Cloranfenicol/análisis , Oro/química , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Plata/química , Espectrometría Raman/métodos , Espectrometría Raman/instrumentación , Contaminación de Alimentos/análisis , Leche/química , ADN Catalítico/química , Animales , Nanopartículas del Metal/química , Antibacterianos/análisis
4.
Se Pu ; 42(5): 474-480, 2024 Apr 08.
Artículo en Chino | MEDLINE | ID: mdl-38736391

RESUMEN

A method was established for the simultaneous detection of 12 prohibited veterinary drugs, including ß2-receptor agonists, nitrofuran metabolites, nitroimidazoles, chlorpromazine, and chloramphenicol, in pig urine. The sample was pretreated by enzymolysis, acid hydrolysis/derivatization, and liquid-liquid extraction combined with solid-phase extraction. Detection was performed using ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Ammonium acetate solution (0.2 mol/L, 4.5 mL) and ß-glucuronidase/aryl sulfatase (40 µL) were added to the sample, which was subsequently enzymolized at 37 ℃ for 2 h. Then, 1.5 mL of 1.0 mol/L hydrochloric acid solution and 100 µL of 0.1 mol/L o-nitrobenzaldehyde solution were added to the sample. The mixture was incubated at 37 ℃ for 16 h, and the analytes were extracted with 8 mL of ethyl acetate by liquid-liquid extraction. The lower aqueous phase obtained after extraction was extracted and purified using a mixed cation-exchange solid-phase extraction column. The extracts were combined, the extraction solution was blow-dried with nitrogen, and the residue was redissolved for determination. The samples were analyzed under multiple-reaction monitoring mode with both positive and negative electrospray ionization, and quantified using an isotope internal standard method. The correlation coefficients (r) of the 12 compounds were >0.99. The limits of detection (LODs) and quantification (LOQs) of chloramphenicol were 0.05 and 0.1 µg/L, respectively, and the LODs and LOQs of the other compounds were 0.25 and 0.5 µg/L, respectively. The mean recoveries and RSDs at 1, 2, and 10 times the LOQ were 83.6%-115.3% and 2.20%-12.34%, respectively. The proposed method has the advantages of high sensitivity, good stability, and accurate quantification; thus, it is suitable for the simultaneous determination of the 12 prohibited veterinary drug residues in pig urine.


Asunto(s)
Residuos de Medicamentos , Espectrometría de Masas en Tándem , Drogas Veterinarias , Animales , Espectrometría de Masas en Tándem/métodos , Porcinos , Cromatografía Líquida de Alta Presión/métodos , Drogas Veterinarias/orina , Drogas Veterinarias/análisis , Residuos de Medicamentos/análisis , Cloranfenicol/orina , Cloranfenicol/análisis
5.
Anal Chim Acta ; 1307: 342631, 2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38719408

RESUMEN

BACKGROUND: Simultaneous detection of food contaminants is crucial in addressing the collective health hazards arising from the presence of multiple contaminants. However, traditional multi-competitive surface-enhanced Raman scattering (SERS) aptasensors face difficulties in achieving simultaneous accurate detection of multiple target substances due to the uncontrollable SERS "hot spots". In this study, using chloramphenicol (CAP) and estradiol (E2) as two target substances, we introduced a novel approach that combines machine learning methods with a dual SERS aptasensor, enabling simultaneous high-sensitivity and accurate detection of both target substances. RESULTS: The strategy effectively minimizes the interference from characteristic Raman peaks commonly encountered in traditional multi-competitive SERS aptasensors. For this sensing system, the Au@4-MBA@Ag nanoparticles modified with sulfhydryl (SH)-CAP aptamer and Au@DTNB@Ag NPs modified with sulfhydryl (SH)-E2 aptamer were used as signal probes. Additionally, Fe3O4@Au nanoflowers integrated with SH-CAP aptamer complementary DNA and SH-E2 aptamer complementary DNA were used as capture probes, respectively. When compared to linear regression random forest, and support vector regression (SVR) models, the proposed artificial neural network (ANN) model exhibited superior precision, demonstrating R2 values of 0.963, 0.976, 0.991, and 0.970 for the training set, test set, validation set, and entire dataset, respectively. Validation with ten spectral groups reported an average error of 244 µg L-1. SIGNIFICANCE: The essence of our study lies in its capacity to address a persistent challenge encountered by traditional multiple competitive SERS aptasensors - the interference generated by uncontrollable SERS "hot spots" that hinders simultaneous quantification. The accuracy of the predictive model for simultaneous detection of two target substances was significantly improved using machine learning tools. This innovative technique offers promising avenues for the accurate and high-sensitive simultaneous detection of multiple food and environmental contaminants.


Asunto(s)
Aptámeros de Nucleótidos , Oro , Aprendizaje Automático , Nanopartículas del Metal , Plata , Espectrometría Raman , Aptámeros de Nucleótidos/química , Plata/química , Oro/química , Nanopartículas del Metal/química , Cloranfenicol/análisis , Estradiol/análisis , Técnicas Biosensibles/métodos , Contaminación de Alimentos/análisis , Límite de Detección
6.
Anal Chim Acta ; 1306: 342598, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38692791

RESUMEN

BACKGROUND: Carbon-based nanozymes have recently received enormous concern, however, there is still a huge challenge for inexpensive and large-scale synthesis of magnetic carbon-based "Two-in-One" mimics with both peroxidase (POD)-like and laccase-like activities, especially their potential applications in multi-mode sensing of antibiotics and neurotransmitters in biofluids. Although some progresses have been made in this field, the feasibility of biomass-derived carbon materials with both POD-like and laccase-like activities by polyatomic doping strategy is still unclear. In addition, multi-mode sensing platform can provide a more reliable result because of the self-validation, self-correction and mutual agreement. Nevertheless, the use of magnetic carbon-based nanozyme sensors for the multi-mode detection of antibiotics and neurotransmitters have not been investigated. RESULTS: We herein report a shrimp shell-derived N, O-codoped porous carbon confined magnetic CuFe2O4 nanosphere with outstanding laccase-like and POD-like activities for triple-mode sensing of antibiotic d-penicillamine (D-PA) and chloramphenicol (CPL), as well as colorimetric detection of neurotransmitters in biofluids. The magnetic CuFe2O4/N, O-codoped porous carbon (MCNPC) armored mimetics was successfully fabricated using a combined in-situ coordination and high-temperature crystallization method. The synthesized MCNPC composite with superior POD-like activity can be used for colorimetric/temperature/smartphone-based triple-mode detection of D-PA and CPL in goat serum. Importantly, the MCNPC nanozyme can also be used for colorimetric analysis of dopamine and epinephrine in human urine. SIGNIFICANCE: This work not only offered a novel strategy to large-scale, cheap synthesize magnetic carbon-based "Two-in-One" armored mimetics, but also established the highly sensitive and selective platforms for triple-mode monitoring D-PA and CPL, as well as colorimetric analysis of neurotransmitters in biofluids without any tanglesome sample pretreatment.


Asunto(s)
Antibacterianos , Carbono , Cobre , Neurotransmisores , Carbono/química , Antibacterianos/análisis , Antibacterianos/orina , Antibacterianos/sangre , Neurotransmisores/orina , Neurotransmisores/análisis , Neurotransmisores/sangre , Porosidad , Cobre/química , Humanos , Nanosferas/química , Colorimetría/métodos , Compuestos Férricos/química , Materiales Biomiméticos/química , Animales , Técnicas Biosensibles/métodos , Cloranfenicol/análisis , Cloranfenicol/orina , Límite de Detección
7.
Anal Methods ; 16(21): 3430-3437, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38766841

RESUMEN

Two levels of nucleic acids-based isothermal amplification normally require a long reaction time due to the low concentration of catalyst, which limits its practical application. A sensitive fluorescence assay of chloramphenicol (CAP) was developed coupled with two-level isothermal amplification using a self-powered catalyzed hairpin assembly (CHA) and entropy-driven circuit (EDC). CAP can bind with its aptamer to open its closed structure. The opened hairpin can initiate self-powered CHA and EDC. The product of CHA can circularly catalyze the CHA with increasing concentration. In principle, the product of CHA plays the role of catalyst and increases with the progression of the reaction. Compared with the normal two levels of amplification, the amplification efficiency of our strategy is much higher due to the self-powered reaction by the CHA product. Thus, the reaction time is shortened to 110 min in this strategy. Moreover, the detection limit for CAP can achieve 0.1 pM and shows promising prospects for practical application.


Asunto(s)
Cloranfenicol , Entropía , Límite de Detección , Técnicas de Amplificación de Ácido Nucleico , Cloranfenicol/análisis , Cloranfenicol/química , Técnicas de Amplificación de Ácido Nucleico/métodos , Catálisis , Espectrometría de Fluorescencia/métodos , Fluorescencia , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Técnicas de Diagnóstico Molecular
8.
J Pharm Biomed Anal ; 245: 116165, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38701534

RESUMEN

Due to antimicrobial resistance that occurs throughout the world, antibiotic-releasing hydrogel with at least two drugs that synergistically treat stubborn bacteria is preferable for infection prevention. Hydrogel can serve as a drug reservoir to gradually release drugs in a therapeutic window to effectively treat microorganisms with minimal side effects. The study and development of drug releasing hydrogels requires a reliable, straightforward, cost-effective, fast, and low labor-intensive drug detection technique. In this study, we validate the electrochemical technique and device setup for real-time determination of dual antibacterial drugs released from a hydrogel. Concentrations of two representative antibacterial drugs, tetracycline (TC) and chloramphenicol (CAP), were determined using square wave voltammetry (SWV) mode that yields the lower limit of detection at 2.5 µM for both drugs. Measurement accuracy and repeatability were verified by 36 known drug combination concentrations. Capability in long-term measurement was confirmed by the measurement stability which was found to last for at least 72 h. Stirring was revealed as one of the significant factors for accurate real-time detection. Real-time measurement was ultimately performed to demonstrate the determination of multiple drug releases from a drug releasing hydrogel and validated by high-performance liquid chromatography (HPLC). All the results support that the electrochemical technique with the proposed device design and setup can be used to accurately and simultaneously determine dual drugs that are released from a hydrogel in real-time.


Asunto(s)
Antibacterianos , Cloranfenicol , Liberación de Fármacos , Técnicas Electroquímicas , Hidrogeles , Tetraciclina , Antibacterianos/análisis , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Hidrogeles/química , Tetraciclina/análisis , Cloranfenicol/análisis , Límite de Detección , Cromatografía Líquida de Alta Presión/métodos , Reproducibilidad de los Resultados
9.
Anal Sci ; 40(7): 1331-1338, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38607597

RESUMEN

A fluorescent immunosorbent assay incorporating signal amplification away from the surface of spherical nucleic acid (SNA) was developed for the detection of chloramphenicol (CAP). Through the conjugation of antibodies and poly-adenine (polyA) DNA onto the surface of gold nanoparticles (AuNPs), the fabrication of the nano-immunoprobe was achieved in a more straightforward and cost-effective manner. Moreover, a strategy utilizing the hybridization chain reaction (HCR) in the amplification step was devised, with particular attention given to the enzyme inhibition associated with SNA. The results demonstrated good performance on CAP detection with a linear range of 0.01-5 ng/L with a detection limit of 0.005 ng/L. The significance of this work mainly lies in the polyA-SNA-based immunoprobe and the thoughtful design to prevent enzyme inhibition.


Asunto(s)
Cloranfenicol , Oro , Nanopartículas del Metal , Cloranfenicol/análisis , Oro/química , Nanopartículas del Metal/química , Poli A/química , Inmunoensayo/métodos , Límite de Detección
10.
Small ; 20(23): e2309075, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38597772

RESUMEN

The improper use and overuse of antibiotics have led to significant burdens and detrimental effects on the environment, food supply, and human health. Herein, a magnetic solid-phase extraction program and an optical immunosensor based on bimetallic Ce/Zr-UiO 66 for the detection of antibiotics are developed. A magnetic Fe3O4@SiO2@Ce/Zr-UiO 66 metal-organic framework (MOF) is prepared to extract and enrich chloramphenicol from fish, wastewater, and urine samples, and a horseradish peroxidase (HRP)-Ce/Zr-UiO 66@bovine serum protein-chloramphenicol probe is used for the sensitive detection of chloramphenicol based on the dual-effect catalysis of Ce and HRP. In this manner, the application of Ce/Zr-UiO 66 in integrating sample pretreatment and antibiotic detection is systematically investigated and the associated mechanisms are explored. It is concluded that Ce/Zr-UiO 66 is a versatile dual-track material exhibiting high enrichment efficiency (6.37 mg g-1) and high sensitivity (limit of detection of 51.3 pg mL-1) for chloramphenicol detection and serving as a multifunctional MOF for safeguarding public health and hygiene.


Asunto(s)
Antibacterianos , Cloranfenicol , Estructuras Metalorgánicas , Estructuras Metalorgánicas/química , Cloranfenicol/análisis , Animales , Humanos , Dióxido de Silicio/química , Cerio/química , Peroxidasa de Rábano Silvestre/química , Peroxidasa de Rábano Silvestre/metabolismo
11.
Chemosphere ; 357: 141981, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38626813

RESUMEN

Metal-Organic Frameworks (MOFs) are extensively used as electrode material in various sensing applications due to their efficacious porous nature and tunable properties. However, pristine MOFs lack conductive attributes that hinder their wide usage in electrochemical applications. Electropolymerization of several aromatic monomers has been a widely used strategy for preparing conducting electrode materials for various sensing applications in the past decades. Herein, we report a similar approach by employing the electropolymerization method to create a functional polymer layer to enhance the sensitivity of an Aluminium Organic Framework (DUT-4) for the selective detection of Chloramphenicol (CAP) antibiotic in aqueous environment. The combined strategy using the conducting polymer layer with the porous Al MOF provides surpassing electrochemical performance for sensing CAP with regard to the very low detection limit (LOD = 39 nM) and exceptionally high sensitivity (11943 µA mM-1 cm-2). In addition, the fabricated sensor exhibited good selectivity, reproducibility and stability. The developed method was successfully evaluated in various real samples including lake water and river water for CAP detection with good recovery percentages even at lower concentrations.


Asunto(s)
Aluminio , Cloranfenicol , Técnicas Electroquímicas , Límite de Detección , Estructuras Metalorgánicas , Polímeros , Contaminantes Químicos del Agua , Cloranfenicol/análisis , Estructuras Metalorgánicas/química , Contaminantes Químicos del Agua/análisis , Aluminio/análisis , Aluminio/química , Polímeros/química , Técnicas Electroquímicas/métodos , Reproducibilidad de los Resultados , Antibacterianos/análisis , Electrodos , Ríos/química , Lagos/química , Lagos/análisis
12.
J Hazard Mater ; 470: 134150, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38552394

RESUMEN

The misuse and overuse of chloramphenicol poses severe threats to food safety and human health. In this work, we developed a magnetic solid-phase extraction (MSPE) pretreatment material coated with a multilayered metal-organic framework (MOF), Fe3O4 @ (ZIF-8)3, for the separation and enrichment of chloramphenicol from fish. Furthermore, we designed an artificial-intelligence-enhanced single microsphere immunosensor. The inherent ultra-high porosity of the MOF and the multilayer assembly strategy allowed for efficient chloramphenicol enrichment (4.51 mg/g within 20 min). Notably, Fe3O4 @ (ZIF-8)3 exhibits a 39.20% increase in adsorption capacity compared to Fe3O4 @ZIF-8. Leveraging the remarkable decoding abilities of artificial intelligence, we achieved the highly sensitive detection of chloramphenicol using a straightforward procedure without the need for specialized equipment, obtaining a notably low detection limit of 46.42 pM. Furthermore, the assay was successfully employed to detect chloramphenicol in fish samples with high accuracy. The developed immunosensor offers a robust point-of-care testing tool for safeguarding food safety and public health.


Asunto(s)
Antibacterianos , Cloranfenicol , Peces , Contaminación de Alimentos , Cloranfenicol/análisis , Animales , Contaminación de Alimentos/análisis , Antibacterianos/análisis , Antibacterianos/química , Estructuras Metalorgánicas/química , Límite de Detección , Inmunoensayo/métodos , Adsorción , Extracción en Fase Sólida/métodos , Inteligencia Artificial , Técnicas Biosensibles/métodos , Óxido Ferrosoférrico/química
13.
Talanta ; 273: 125857, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38490024

RESUMEN

An electrochemical aptasensor was developed for the determination of chloramphenicol (CAP) in fresh foods and food products. The aptasensor was developed using Prussian blue (PB) and chitosan (CS) film. PB acts as a redox probe for detection and CS acts as a sorption material. The aptamer (Apt) was immobilized on a screen-printed carbon electrode (SPCE) modified with gold nanoparticles (AuNPs). Under optimum conditions, the linearity of the aptasensor was between 1.0 and 6.0 × 106 ng L-1 with a detection limit of 0.65 and a quantification limit of 2.15 ng L-1. The electrode could be regenerated up to 24 times without the use of chemicals. The aptasensor showed good repeatability (RSD <11.2%) and good reproducibility (RSD <7.7%). The proposed method successfully quantified CAP in milk, shrimp pond water and shrimp meat with good accuracy (recovery = 88.0 ± 0.6% to 100 ± 2%). The proposed aptasensor could be especially useful in agriculture to ensure the quality of food and the environment and could be used to determine other antibiotics.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Quitosano , Ferrocianuros , Nanopartículas del Metal , Carbono , Oro , Límite de Detección , Cloranfenicol/análisis , Reproducibilidad de los Resultados , Electrodos , Carne , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos
14.
Food Chem ; 444: 138637, 2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-38341918

RESUMEN

The use of Chloramphenicol (CAP), a potent antibiotic with broad-spectrum capabilities in food-producing animals has been restricted by the European Union and several other countries due to its severe side effects. Thus, CAP must be detected quickly and sensitively. In this investigation, the preparation of SrTiO3 nanoparticles was carried out utilizing a hydrothermal technique. The as-synthesized strontium titanate was decorated on the graphene oxide (SrTiO3/GO) using an ultrasonication method. An electrochemical sensor was developed by employing a modified electrode consisting of SrTiO3/GO, which can accurately detect CAP in food samples. The synergistic effect of SrTiO3 and GO could improve the peak current response. Remarkably, the SrTiO3/GO-modified glassy carbon electrode has a LOD and sensitivity of 6.08 µM nM and 2.771 µA·µM-1·cm-2, respectively. This modified electrode was evaluated in food samples and had an outstanding reaction with a high percentage of recovery, which makes it a potential electrocatalyst for CAP detection.


Asunto(s)
Grafito , Miel , Nanopartículas del Metal , Animales , Cloranfenicol/análisis , Miel/análisis , Grafito/química , Nanopartículas del Metal/química , Técnicas Electroquímicas/métodos , Electrodos , Límite de Detección
15.
Chemosphere ; 352: 141455, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38367872

RESUMEN

The occurrence of antibiotic residues in the environment has received considerable attention because of their potential to select for bacterial resistance. The overuse of antibiotics in human medicine and animal production results in antibiotic residues entering the aquatic environment, but concentrations are currently not well determined. This study investigates the occurrence of antibiotics in groundwater in areas strongly related to agriculture and the antibiotic treatment of animals. A multiresidue method was validated according to EU Regulation 2021/808, to allow (semi-)quantitative analysis of 78 antibiotics from 10 different classes: ß-lactams, sulfonamides, tetracyclines, lincosamides, amphenicols, (fluoro)quinolones, macrolides, pleuromutilins, ansamycins and diaminopyrimidines using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). This method was used to test different storage conditions of these water samples during a stability study over a period of 2 weeks. Sulfonamides, lincosamides and pleuromutilins were the most stable. Degradation was most pronounced for ß-lactam antibiotics, macrolides and ansamycins. To maintain stability, storage of samples at -18 °C is preferred. With the validated method, antibiotic residues were detected in groundwater, sampled from regions associated with intensive livestock farming in Flanders (Belgium). Out of 50 samples, 14% contained at least one residue. Concentrations were low, ranging from < LOD to 0.03 µg/L. Chloramphenicol, oxolinic acid, tetracycline and sulfonamides (sulfadiazine, sulfadoxine, sulfamethazine and sulfisoxazole) were detected. This study presents a new method for the quantification of antibiotic residues, which was applied to investigate the presence of antibiotic residues in groundwater in Flanders.


Asunto(s)
Residuos de Medicamentos , Agua Subterránea , Animales , Humanos , Antibacterianos/análisis , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Lactamas Macrocíclicas/análisis , Sulfanilamida/análisis , Cloranfenicol/análisis , Sulfonamidas/análisis , Lincosamidas , Pleuromutilinas , Macrólidos/análisis , Residuos de Medicamentos/análisis
16.
J Fish Dis ; 47(2): e13884, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37929301

RESUMEN

The mucus layers of fish serve as the main interface between the organism and the environment. They play an important biological and ecological role. The current study focuses on Nile tilapia epidermal mucus reared under different commercial feeds (coded A and B) and environments (biofloc technology and earthen pond systems). Crude protein levels in feed A and B were 30% and 28%, respectively. Water parameters in all culturing systems were suitable for tilapia throughout the study period. The antimicrobial potency of tilapia (n = 5 from each) epidermal mucus was tested in vitro against human and fish pathogenic strains viz. Staphylococcus epidermidis, Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa, Francisella noatunensis, and Aeromonas hydrophila. To determine the antimicrobial activity, zones of inhibition (ZOI) were measured in millimetres and compared with two antibiotics (chloramphenicol and ciprofloxacin). SDS-PAGE analysis was performed on skin mucus samples of tilapia to determine protein quantity and size (molecular weight). Results of tilapia skin mucus (crude and aqueous) revealed a strong antibacterial effect against all the selected pathogenic strains. However, variation has been observed in the mucus potency and ZOI values between the biofloc and pond tilapia mucus. The crude mucus of tilapia fed on feed A and cultured in the pond exhibited strong antibacterial effects and high ZOI values compared to the mucus of biofloc tilapia, aqueous mucus extracts and positive control chloramphenicol (antibiotic). The SDS-PAGE results showed that the high molecular weight proteins were found in the collected epidermal mucus of BFT-B (240 kDa) and EP-B (230 kDa). Several peptides in fish skin mucus may play a crucial role in the protection of fish against disease-causing pathogens. Thus, it can be utilized in the human and veterinary sectors as an 'antimicrobial' for treating various bacterial infections.


Asunto(s)
Antiinfecciosos , Cíclidos , Enfermedades de los Peces , Tilapia , Animales , Alimentación Animal/análisis , Antibacterianos/farmacología , Acuicultura/métodos , Cloranfenicol/análisis , Dieta/veterinaria , Enfermedades de los Peces/prevención & control , Enfermedades de los Peces/microbiología , Moco/química , Estanques , Tilapia/microbiología
17.
J AOAC Int ; 107(2): 267-276, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38039152

RESUMEN

BACKGROUND: The consumption of foods containing amphenicols, a type of antibiotic, is a major concern for human health. A stable and accurate detection method can provide technical support for food-safety monitoring. OBJECTIVE: An effective and efficient method was established for determining amphenicols in animal-derived foods through the simultaneous use of solid-phase extraction (SPE) cleanup and ultrahigh-performance liquid chromatography/mass spectrometry (UPLC-MS/MS). METHOD: Samples were extracted using 1.0% ammoniated ethyl acetate solution, degreased with n-hexane, and then concentrated and cleaned using a C18 SPE column. Next, gradient elution was performed using methanol and 0.05% aqueous ammonia as the mobile phase, followed by separation using a C18 column. The target compound was detected using electrospray ionization, both in positive and negative modes, through multiple reaction monitoring, and quantified using an internal-standard method. RESULTS: The content of chloramphenicol (CAP), florfenicol (FF), and florfenicol amine (FFA) (content range: 0.2-8.0 µg/kg) as well as that of thiamphenicol (TAP; content range: 1.0-40.0 µg/kg) show a good linear relationship, with a correlation coefficient of r > 0.999. Furthermore, recoveries of 86.7-111.9% and relative standard deviations of <9.0% were achieved. The limits of detection and quantification are obtained as 0.03-0.33 and 0.1-1.0 µg/kg, respectively. CONCLUSIONS: The proposed method has excellent stability and accuracy, and can be successfully used for the qualitative and quantitative determination of amphenicols, i.e., CAP, TAP, FF, and FFA residues in 210 animal-derived food samples, of which FF and FFA were detected in four samples. HIGHLIGHTS: A stable and accurate method was successfully established for the simultaneous determination of CAP, TAP, FF, and FFA in animal-derived foods using UPLC-MS/MS. Effective sample pretreatment was established, lipids were removed using n-hexane, concentration and cleanup were achieved with the C18 SPE column, and matrix effects were effectively reduced, thus improving the method's accuracy and stability. The method was validated for eight common animal-source foods, including beef, lamb, pork, chicken, egg, milk, fish, and honey. This method has good applicability for CAP, TAP, FF, and FFA in animal-derived foods.


Asunto(s)
Cloranfenicol , Hexanos , Espectrometría de Masas en Tándem , Tianfenicol/análogos & derivados , Bovinos , Humanos , Animales , Ovinos , Cloranfenicol/análisis , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Solventes , Antibacterianos/análisis , Pollos , Extracción en Fase Sólida
18.
J Pharm Biomed Anal ; 239: 115913, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38134703

RESUMEN

Determination of pharmaceutical active molecules in the biological matrices is crucial in various fields of clinical and pharmaceutical chemistry, e.g., in pharmacokinetic studies, developing new drugs, or therapeutic drug monitoring. Chloramphenicol (CP) is used for treating bacterial infections, and it's one of the first antibiotics synthetically manufactured on a large scale. Fabric phase sorptive extraction (FPSE) was used to determine Chloramphenicol antibiotic residues in milk samples by means of validated HPLC-DAD instrumentation. Cellulose fabric phases modified with polyethylene glycol-block-polypropylene glycol-block-polyethylene glycol triblock copolymer was synthesized using sol-gel synthesis approach (Sol-gel PEG-PPG-PEG) and used for batch-type fabric phase extractions. Experimental variables of the FPSE method for antibiotic molecules were investigated and optimized systematically. The HPLC analysis of chloramphenicol was performed using a C18 column, isocratic elution of trifluoroacetic acid (0.1%), methanol, and acetonitrile (17:53:30) with a flow rate of 1.0 mL/min. The linear range for the proposed method for chloramphenicol (r2 > 0.9982) was obtained in the range of 25.0-1000.0 ng/mL. The limit of detections (LOD) is 8.3 ng/mL, while RSDs% are below 4.1%. Finally, the developed method based on FPSE-HPLC-DAD was applied to milk samples to quantitatively determine antibiotic residues.


Asunto(s)
Cloranfenicol , Leche , Animales , Cloranfenicol/análisis , Leche/química , Antibacterianos/análisis , Cromatografía Líquida de Alta Presión/métodos , Polietilenglicoles/análisis
19.
J Water Health ; 21(11): 1703-1715, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38017600

RESUMEN

Illegal mining has overshadowed pharmaceutical pollution even though exposure to pharmaceutical waste is high. Consumption of fish potentially polluted with pharmaceuticals from the rivers continues with little concern or potential threat it poses. In the present study, the residues of one antibiotic (Chloramphenicol), five hormones (progesterone, 17-beta Estradiol, Estrone, 17a-Ethynylestradiol, and one), three environmental contaminants (4-para-nonylphenol, 4-tert-octylphenol, and Bisphenol A), one barbiturate (Primidone) and one analgesic (Diclofenac sodium salt), were investigated from fish samples from the rivers Pra, Narkwa, and the Volta. The results show a high concentration of drugs in River Pra in comparison to those in Rivers Narkwa and Volta. The hazard quotients (HQs) for the environmental contaminants were all above 1, except Bisphenol A. Furthermore, the HQs from this study suggest that consumers of fish from any of the three rivers stand a hazard risk of Chloramphenicol (19), 17a-Ethynylestradiol (4), Estrone (1.366), Diclofenac sodium salt (3.29), Progesterone (4.598), 4-tert-octylphenol (87.2), and 4-para-nonylphenol (7.252), but negligible risk against E2 (0.687), Primidone (0.014), Testosterone (0.16), and Bisphenol A (0.642). Of the fish species studied, the highest concentration of all pharmaceuticals put together is found in Clarias gariepinus, Labeo senegalensis, and Chrysichthys nigrodigitatus in that order.


Asunto(s)
Bagres , Contaminantes Químicos del Agua , Animales , Estrona , Progesterona/análisis , Ghana , Primidona/análisis , Diclofenaco , Preparaciones Farmacéuticas , Medición de Riesgo , Cloranfenicol/análisis , Agua , Contaminantes Químicos del Agua/análisis , Ríos/química , Monitoreo del Ambiente/métodos
20.
Biosensors (Basel) ; 13(6)2023 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-37367025

RESUMEN

Aptamers are an excellent choice for the selective detection of small molecules. However, the previously reported aptamer for chloramphenicol suffers from low affinity, probably as a result of steric hindrance due to its bulky nature (80 nucleotides) leading to lower sensitivity in analytical assays. The present work was aimed at improving this binding affinity by truncating the aptamer without compromising its stability and three-dimensional folding. Shorter aptamer sequences were designed by systematically removing bases from each or both ends of the original aptamer. Thermodynamic factors were evaluated computationally to provide insight into the stability and folding patterns of the modified aptamers. Binding affinities were evaluated using bio-layer interferometry. Among the eleven sequences generated, one aptamer was selected based on its low dissociation constant, length, and regression of model fitting with association and dissociation curves. The dissociation constant could be lowered by 86.93% by truncating 30 bases from the 3' end of the previously reported aptamer. The selected aptamer was used for the detection of chloramphenicol in honey samples, based on a visible color change upon the aggregation of gold nanospheres caused by aptamer desorption. The detection limit could be reduced 32.87 times (1.673 pg mL-1) using the modified length aptamer, indicating its improved affinity as well as its suitability in real-sample analysis for the ultrasensitive detection of chloramphenicol.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Miel , Nanopartículas del Metal , Cloranfenicol/análisis , Cloranfenicol/química , Aptámeros de Nucleótidos/química , Nanopartículas del Metal/química , Oro/química , Miel/análisis , Técnicas Biosensibles/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...