Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 43(2): 132-135, 2019 Mar 30.
Artículo en Chino | MEDLINE | ID: mdl-30977614

RESUMEN

The work explored the DEHP migration parameters in PVC infusion in clinic,based on the previous research on the test model of DEHP migrated from PVC infusion,to assess the safety of PVC infusion.The leaching solution samples in different conditions were evaluated by analysis of the DEHP in leaching solution using GC-MS under simulated clinical transfusion way.The release behavior of DEHP was significantly affected by the storage time,storage temperature,surrounding temperature,dripping speed,sterilization process,volume of the leaching solution,and the property of the leaching solution.


Asunto(s)
Dietilhexil Ftalato , Plastificantes , Cloruro de Polivinilo , Dietilhexil Ftalato/farmacocinética , Cromatografía de Gases y Espectrometría de Masas , Plastificantes/farmacocinética , Cloruro de Polivinilo/farmacocinética , Temperatura
2.
Int J Pharm ; 496(2): 664-75, 2015 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-26561727

RESUMEN

The sorption of a drug by an infusion set may dramatically reduce the drug delivery efficiency. In this paper, we investigated how the drug sorption, in static conditions, is affected by the plasticizer's nature and ratio in the case of plasticized PVC, one of the most common material for infusion set tubing. Within the study, the drug concentration in diazepam solutions was studied after contact with PVC films containing different amounts of DEHP, DEHT, TOTM and DINCH® plasticizers. Moreover the partition coefficients between material and water were calculated. The drug sorption levels were equivalent for the different plasticizers and there was a plasticizer ratio for which the drug uptake was enhanced. As a consequence, the amount of sorbed drug might not be only linked to the amount of plasticizer in the film and to the solubility of the drug in the plasticizer alone: it must probably depend on specific interactions between plasticizer and PVC.


Asunto(s)
Diazepam/metabolismo , Plastificantes/química , Plastificantes/farmacocinética , Cloruro de Polivinilo/química , Cloruro de Polivinilo/farmacocinética
3.
Proc Natl Acad Sci U S A ; 110(43): 17199-204, 2013 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-24108356

RESUMEN

We have created unique near-infrared (NIR)-emitting nanoscale metal-organic frameworks (nano-MOFs) incorporating a high density of Yb(3+) lanthanide cations and sensitizers derived from phenylene. We establish here that these nano-MOFs can be incorporated into living cells for NIR imaging. Specifically, we introduce bulk and nano-Yb-phenylenevinylenedicarboxylate-3 (nano-Yb-PVDC-3), a unique MOF based on a PVDC sensitizer-ligand and Yb(3+) NIR-emitting lanthanide cations. This material has been structurally characterized, its stability in various media has been assessed, and its luminescent properties have been studied. We demonstrate that it is stable in certain specific biological media, does not photobleach, and has an IC50 of 100 µg/mL, which is sufficient to allow live cell imaging. Confocal microscopy and inductively coupled plasma measurements reveal that nano-Yb-PVDC-3 can be internalized by cells with a cytoplasmic localization. Despite its relatively low quantum yield, nano-Yb-PVDC-3 emits a sufficient number of photons per unit volume to serve as a NIR-emitting reporter for imaging living HeLa and NIH 3T3 cells. NIR microscopy allows for highly efficient discrimination between the nano-MOF emission signal and the cellular autofluorescence arising from biological material. This work represents a demonstration of the possibility of using NIR lanthanide emission for biological imaging applications in living cells with single-photon excitation.


Asunto(s)
Elementos de la Serie de los Lantanoides/química , Nanopartículas del Metal/química , Espectroscopía Infrarroja Corta/métodos , Iterbio/química , Animales , Cristalización , Células HeLa , Humanos , Elementos de la Serie de los Lantanoides/farmacocinética , Nanopartículas del Metal/ultraestructura , Ratones , Microscopía Confocal , Microscopía Electrónica de Rastreo , Microscopía Fluorescente , Células 3T3 NIH , Fotones , Cloruro de Polivinilo/análogos & derivados , Cloruro de Polivinilo/química , Cloruro de Polivinilo/farmacocinética , Espectroscopía Infrarroja por Transformada de Fourier , Termogravimetría , Difracción de Rayos X , Iterbio/farmacocinética
4.
J Expo Sci Environ Epidemiol ; 21(2): 133-41, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-20010977

RESUMEN

Improved analytical methods for measuring urinary phthalate metabolites have resulted in biomarker-based estimates of phthalate daily intake for the general population, but not for occupationally exposed groups. In 2003-2005, we recruited 156 workers from eight industries where materials containing diethyl phthalate (DEP), dibutyl phthalate (DBP), and/or di(2-ethylhexyl) phthalate (DEHP) were used as part of the worker's regular job duties. Phthalate metabolite concentrations measured in the workers' end-shift urine samples were used in a simple pharmacokinetic model to estimate phthalate daily intake. DEHP intake estimates based on three DEHP metabolites combined were 0.6-850 µg/kg/day, with the two highest geometric mean (GM) intakes in polyvinyl chloride (PVC) film manufacturing (17 µg/kg/day) and PVC compounding (12 µg/kg/day). All industries, except phthalate manufacturing, had some workers whose DEHP exposure exceeded the U.S. reference dose (RfD) of 20 µg/kg/day. A few workers also exceeded the DEHP European tolerable daily intake (TDI) of 50 µg/kg/day. DEP intake estimates were 0.5-170 µg/kg/day, with the highest GM in phthalate manufacturing (27 µg/kg/day). DBP intake estimates were 0.1-76 µg/kg/day, with the highest GMs in rubber gasket and in phthalate manufacturing (17 µg/kg/day, each). No DEP or DBP intake estimates exceeded their respective RfDs. The DBP TDI (10 µg/kg/day) was exceeded in three rubber industries and in phthalate manufacturing. These intake estimates are subject to several uncertainties; however, an occupational contribution to phthalate daily intake is clearly indicated in some industries.


Asunto(s)
Industria Química , Monitoreo del Ambiente/métodos , Exposición Profesional/análisis , Ácidos Ftálicos/orina , Biomarcadores/orina , Dibutil Ftalato/farmacocinética , Dibutil Ftalato/orina , Dietilhexil Ftalato/farmacocinética , Dietilhexil Ftalato/orina , Femenino , Humanos , Masculino , Ácidos Ftálicos/farmacocinética , Cloruro de Polivinilo/metabolismo , Cloruro de Polivinilo/farmacocinética , Medición de Riesgo , Incertidumbre
5.
Perfusion ; 25(1): 31-9, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20159936

RESUMEN

BACKGROUND: The use of Di-2-ethylhexyl phthalate (DEHP) plasticised polyvinyl chloride (DEHPPPVC) in medical devices persists despite evidence suggesting that DEHP migration can be harmful. Researchers have shown that a simple surface sulfonation process can retard the migration of DEHP, which may reduce the associated inflammatory response. The present study is designed to investigate the effects of surface sulfonation on DEHP migration and blood contact activation using in vitro and rodent models. METHODS: The study was carried out in two phases: phase 1, in which the migration rate of DEHP from DEHPPPVC and sulfonated DEHP plasticised PVC (SDEHPPPVC) was measured; phase 2 of the study, in which the materials were incorporated into a rat recirculation biomaterial test model and blood samples taken to assess CD11b expression on neutrophils, IL-6 and Factor XIIa. RESULTS: The initial DEHP concentration washed from the surface after storage was 37.19 +/- 1.17 mg/l in the PPVC group and 5.89 +/- 0.81 mg/l in the SPPVC group (p<0.0001). The post-wash migration rate was 3.07 +/- 0.32 mg/l/hour in the PPVC group compared to 0.46 +/- 0.038 mg/l/hour in the SPPVC group (p<0.0001). In phase 2 of the study, CD11b expression increased by 228.9% +/- 37% over the test period in the PPVC group compared to 118.3% +/- 46% in the SPPVC group (p<0.01). IL-6 levels rose from 3.1 +/- 1.4 pg/ml to 263 +/- 26 pg/ml in the PPVC group and 2.2 +/- 1.6 pg/ml to 161 +/- 29 pg/ml in the SPPVC group (p<0.01). Factor XIIa levels rose from 0.22 +/- 0.13 g/ml to 3.7 +/- 0.32 microg/ml and 0.28 +/- 0.09 to 2.71 +/- 0.21 microg/ml in the PPVC and SPPVC groups, respectively (p<0.05 at 90 minutes). CONCLUSIONS: The simple sulfonation process significantly retards the migration of DEHP and is associated with the moderation of contact activation processes.


Asunto(s)
Dietilhexil Ftalato/farmacocinética , Circulación Extracorporea/instrumentación , Inflamación/inducido químicamente , Cloruro de Polivinilo/farmacocinética , Compuestos de Amonio Cuaternario/farmacología , Alcanosulfonatos , Animales , Antígeno CD11b/metabolismo , Dietilhexil Ftalato/efectos adversos , Dietilhexil Ftalato/inmunología , Circulación Extracorporea/efectos adversos , Factor XIIa/metabolismo , Citometría de Flujo , Inflamación/sangre , Interleucina-6/sangre , Masculino , Modelos Animales , Neutrófilos/efectos de los fármacos , Neutrófilos/inmunología , Neutrófilos/metabolismo , Plastificantes/efectos adversos , Plastificantes/farmacocinética , Cloruro de Polivinilo/efectos adversos , Compuestos de Amonio Cuaternario/química , Ratas , Ratas Sprague-Dawley
6.
Biomacromolecules ; 5(5): 2034-41, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15360321

RESUMEN

Nitric oxide (NO) releasing sol-gel materials coated with poly(vinyl chloride) (PVC) films exhibit increased stability at ambient and physiological temperatures. The polymer overcoat, however, reduces the NO fluxes by 5-35% over the initial week of release. The variation in NO fluxes between unmodified and PVC-coated sol-gels is negligible after 7 days. The PVC polymeric layer provides controlled surface chemistry for systematic studies of the effects of NO release on bacterial adhesion. As an example, the adhesion of Pseudomonas aeruginosa and Proteus mirabilis at PVC-coated NO-releasing sol-gels is investigated. A direct NO dependence on the reduction of P. aeruginosa adhesion is observed for NO fluxes up to 20 pmol cm(-2) s(-1). Although decreased by 50% in the presence of NO release, P. mirabilis adhesion does not appear to correlate to the flux of NO release. PVC-coated NO-releasing sol-gels may prove useful for studying the effects of localized NO release on other biological and chemical systems.


Asunto(s)
Adhesión Bacteriana/fisiología , Geles/química , Óxido Nítrico/farmacocinética , Polimetil Metacrilato/química , Cloruro de Polivinilo/química , Geles/farmacocinética , Óxido Nítrico/química , Transición de Fase , Polimetil Metacrilato/farmacocinética , Cloruro de Polivinilo/farmacocinética
7.
Int J Pharm ; 274(1-2): 119-29, 2004 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-15072788

RESUMEN

This study deals with in vitro investigation of the release of di(2-ethylhexyl)phthalate (DEHP) during hemodialysis and pump-oxygenation therapy using medical grade PVC tubing. High resolution GC-MS analysis showed that the release of DEHP was time-dependently increased by circulation of bovine blood into a major system for the hemodialysis that is used in Japan, and the amount of DEHP released into the blood had reached 7.3 mg by 4 h of circulation. No significant difference was observed in the release patterns of DEHP under the conditions with and without fluid removal treatment during hemodialysis, indicating that the treatment seems not to be effective for eliminating DEHP from the blood through the hemodialysis membrane. Mono(2-ethylhexyl)phthalate (MEHP) analysis revealed that a small amount of DEHP (3-4%) was converted to MEHP by hydrolysis during the circulation of blood. A considerable amount of DEHP was also released from the PVC circuit mimicking the pump-oxygenation system, and 7.5-12.1 mg of DEHP had migrated into bovine blood from the circuit by 6 h. It was noticed, however, that the release was obviously suppressed by covalently coating the inner surface of the PVC tubing with heparin, though this effect was not observed with ionic bond type-heparin coating. Covalent bond type-heparin coating of PVC tubing seems to offer the advantage of decreasing the amount of DEHP exposure to patients during treatment using a PVC circuit.


Asunto(s)
Dietilhexil Ftalato/sangre , Dietilhexil Ftalato/farmacocinética , Cloruro de Polivinilo/farmacocinética , Diálisis Renal/instrumentación , Adulto , Animales , Bovinos , Humanos , Diálisis Renal/efectos adversos , Diálisis Renal/métodos , Reproducibilidad de los Resultados , Medición de Riesgo
8.
J Pharm Biomed Anal ; 31(6): 1145-52, 2003 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-12667930

RESUMEN

Health Canada reported recently that medical devices containing di(2-ethylhexyl) phthalate (DEHP) should not be used in the clinical treatment of infants, young boys, pregnant women, and nursing mothers. The risk assessment of DEHP released from PVC medical devices is an important issue for hospitalized patients. In this study, a simple, accurate, low-contamination and high-throughput analytical technique for the determination of DEHP in intravenous (IV) solution was developed using column-switching liquid chromatography/mass spectrometry (LC/MS) with an extraction mini-column. The sample preparation for on-line extraction involved simply mixing IV solution with internal standard as DEHP-d(4) in LC glass vials. The IV fat emulsion drug sample cannot be analyzed directly, hence this sample spiked with DEHP-d(4) solution was extracted by hexane and measured by column-switching LC/MS yielding an average recovery of 92.2% (C.V.=7.8%, n=5). A linear response was found for a variety of drugs tested within the validated range of 0.1 or 0.5-10 microg/ml with correlation coefficients (r) greater than 0.99. These results suggest that this method can assay background exposure to DEHP released from PVC medical devices in the patients. The method was applied to various IV solution samples to establish the first screening method for DEHP released from medical devices with respect to their safety.


Asunto(s)
Dietilhexil Ftalato/análisis , Dietilhexil Ftalato/farmacocinética , Cloruro de Polivinilo/análisis , Cloruro de Polivinilo/farmacocinética , Cromatografía Líquida de Alta Presión/métodos , Equipos y Suministros/normas , Infusiones Intravenosas , Soluciones Farmacéuticas/análisis , Soluciones Farmacéuticas/farmacocinética , Espectrometría de Masa por Ionización de Electrospray/métodos
9.
Pharm Res ; 19(6): 818-24, 2002 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12134952

RESUMEN

PURPOSE: Ventilator-associated pneumonia is a frequent cause of mortality in intensive care patients. This study describes the physicochemical properties of hexetidine-impregnated poly(vinyl chloride) (PVC) endotracheal tube (ET) biomaterials and their resistance to microbial adherence (Staphylococcus aureus and Pseudomonas aeruginosa). METHODS: PVC emulsion was cured in the presence of hexetidine (0-20% w/w) and was characterized in terms of drug release, surface properties (i.e., microrugosity/contact angle), mechanical (tensile) properties, and resistance to microbial adherence. RESULTS: Under sink conditions, hexetidine release from PVC was diffusion-controlled. Increasing the concentration of hexetidine from 1% to 10% (w/w) (but not from 10% to 20% w/w) increased the subsequent rate of drug release. In general, increasing the concentration of hexetidine decreased both the tensile properties and hydrophobicity, yet increased PVC microrugosity. Following hexetidine release (21 days), the surface properties were similar to those of native PVC. The resistance of hexetidine-containing PVC (1% or 5%) to microbial adherence (following defined periods of drug release) was greater than that of native PVC and was constant over the examined period of hexetidine release. CONCLUSIONS: ET PVC containing 1% (w/w) hexetidine offered an appropriate balance between suitable physicochemical properties and resistance to microbial adherence. This may offer an approach with which to reduce the incidence of ventilator-associated pneumonia.


Asunto(s)
Adhesión Bacteriana , Hexetidina/farmacocinética , Intubación Intratraqueal , Cloruro de Polivinilo/farmacocinética , Pseudomonas aeruginosa/efectos de los fármacos , Staphylococcus aureus/efectos de los fármacos , Análisis de Varianza , Adhesión Bacteriana/efectos de los fármacos , Biopelículas/efectos de los fármacos , Biopelículas/crecimiento & desarrollo , Fenómenos Químicos , Química Física , Resistencia a Medicamentos/fisiología , Hexetidina/química , Humanos , Intubación Intratraqueal/métodos , Neumonía Bacteriana/prevención & control , Cloruro de Polivinilo/química , Cloruro de Polivinilo/farmacología , Pseudomonas aeruginosa/crecimiento & desarrollo , Infecciones del Sistema Respiratorio/prevención & control , Staphylococcus aureus/crecimiento & desarrollo
10.
J Biomed Mater Res ; 61(2): 252-9, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12007206

RESUMEN

Poly(vinyl chlorides)-graft-[omega-stearyl-poly(ethylene oxide)] (PVC-g-SPEO), which has a poly(vinyl chloride) (PVC) backbone, poly(ethylene oxide) (PEO) side chain, and stearyl end groups, has been synthesized. Self-organizing blends of the amphiphilic comb polymer in poly(vinyl chlorides) have been examined as a means to create albumin preferential surfaces on polymer films. X-ray photoelectron spectroscopy (XPS) analysis indicates substantial surface segregation of the PVC-g-SPEO. A surface concentration of 59.9 EO wt % is achieved by the solution casting and heat treatment of a film with a bulk concentration of only 3.78 EO wt %. In the aqueous environment, the surface rearrangement of PVC-g-SPEO/PVC blend film is limited and presents a high interfacial energy and high depolar component of interfacial energy due to the "tail-like" SPEO side chain. Protein adsorption tests confirm that PVC-g-SPEO/PVC blend films absorb high levels of albumin and dramatically resist fibrinogen adsorption. Surfaces to attract and reversibly bind albumin, which might diminish the occurrence of thrombosis, inflammation, and infection, are developed by self-organizing blends of the amphiphilic comb polymer in poly(vinyl chlorides).


Asunto(s)
Cloruro de Polivinilo/farmacocinética , Albúmina Sérica/metabolismo , Adsorción , Dimerización , Humanos , Membranas Artificiales , Polietilenglicoles/farmacocinética , Unión Proteica , Estearatos/farmacocinética , Propiedades de Superficie
11.
J Pharm Pharmacol ; 45(8): 748-9, 1993 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-7901375

RESUMEN

The sorption of calcitriol into PVC from an injectable formulation containing Tween 20, a nonionic surfactant, was studied. The amount of drug sorbed by the plastic decreased as the concentration of the surfactant increased. The apparent partition parameter of the drug between PVC strips and the solution was experimentally determined at three different concentrations of the surfactant. A physical model was developed to describe mathematically the partition equilibrium of the drug between the plastic solid phase, the micellar phase of the surfactant, and the aqueous phase of the solution. This model also allowed the calculation of the drug/plastic and drug/micelle partition parameters using the experimentally determined apparent partition parameters.


Asunto(s)
Calcitriol/química , Polisorbatos/química , Cloruro de Polivinilo/farmacocinética , Absorción , Fenómenos Químicos , Química Física , Infusiones Intravenosas , Cómputos Matemáticos , Micelas , Modelos Químicos , Soluciones , Tensoactivos/química , Tensoactivos/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...