Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
FEMS Microbiol Rev ; 44(4): 399-417, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32386213

RESUMEN

Miramistin is a topical antiseptic with broad antimicrobial action, including activity against biofilms and a clinical profile showing good tolerability. Miramistin was developed within a framework of the Soviet Union Cold War Space Program. It is available for clinical use in several prior Soviet bloc countries, but barely known outside of these countries and there is almost no mention of miramistin in the English literature. However, considering emerging antimicrobial resistance, the significant potential of miramistin justifies its re-evaluation for use in other geographical areas and conditions. The review consists of two parts: (i) a review of the existing literature on miramistin in English, Russian and Ukrainian languages; (ii) a summary of most commonly used antiseptics as comparators of miramistin. The oral LD50 was 1200 mg/kg, 1000 mg/kg and 100 g/L in rats, mice and fish, respectively. Based on the results of the review, we suggest possible applications of miramistin and potential benefits over currently used agents. Miramistin offers a novel, low toxicity antiseptic with many potential clinical uses that need better study which could address some of the negative impact of antimicrobial, antiseptic and disinfectant resistance.


Asunto(s)
Compuestos de Benzalconio , Animales , Antiinfecciosos/farmacología , Antiinfecciosos/toxicidad , Antiinfecciosos Locales/farmacología , Antiinfecciosos Locales/toxicidad , Compuestos de Benzalconio/historia , Compuestos de Benzalconio/farmacología , Compuestos de Benzalconio/normas , Compuestos de Benzalconio/toxicidad , Supervivencia Celular/efectos de los fármacos , Historia del Siglo XX , Dosificación Letal Mediana , Federación de Rusia , U.R.S.S.
2.
Pharmeur Bio Sci Notes ; 2012: 87-102, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23327894

RESUMEN

NMR spectrometry has many analytical applications; for instance, the identification of known substances; the structure elucidation of unknown ones; the quantification of APIs, impurities, solvent and water; kinetic studies, stereochemistry determinations, and the analyses of complex mixtures as in metabonomics. NMR spectrometry has the potential to substitute or complement existing analyses that are performed on APIs. In this work, 4 different NMR analyses were done on 2 APIs: fluvastatin sodium and benzalkonium chloride with good results.


Asunto(s)
Compuestos de Benzalconio/normas , Contaminación de Medicamentos , Ácidos Grasos Monoinsaturados/normas , Indoles/normas , Espectroscopía de Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/normas , Farmacopeas como Asunto , Compuestos de Benzalconio/aislamiento & purificación , Estabilidad de Medicamentos , Ácidos Grasos Monoinsaturados/aislamiento & purificación , Estudios de Factibilidad , Fluvastatina , Indoles/aislamiento & purificación , Espectroscopía de Resonancia Magnética/instrumentación , Estructura Molecular , Farmacopeas como Asunto/normas , Protones , Agua/análisis
3.
PDA J Pharm Sci Technol ; 59(5): 332-7, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16316068

RESUMEN

A simple and rapid analytical procedure for routine quantification of n-C12H25 and n-C14H29 benzalkonium chloride (C-12 and C-14 BKC) homologs in ophthalmic formulations containing antazoline HCl and tetrahydrozoline HCl by high-performance liquid chromatography was developed and validated. The ophthalmic solution samples can be directly analyzed by reversed-phase on HiQ-Sil C18 column (4.6 mm x 150 mm, i.d., 5-microm particle size) with acetonitrile-sodium acetate buffer (pH 5.0; 0.2 M) (70:30, v/v) as mobile phase. UV Detection was carried out at 262 nm. The method was linear over the selected concentration and ranged from 0.03 to 0.10 mg/ml (r2 = 0.9999) and from 0.01 to 0.05 mg/ml (r2 = 0.9979) for C-12 and C-14 BKC homologs, respectively. The mean percent recoveries were 100.2 and 102.6 and the percent CV values were 1.3 and 3.5 for C-12 and C-14 BKC homologs, respectively. The results demonstrated the good linearity, accuracy, and precision. The method was applied to determine two commercial ophthalmic formulations, and the percent label amounts of total BKC contents were found to be 99.7 and 103.2.


Asunto(s)
Antazolina/análisis , Compuestos de Benzalconio/análisis , Cromatografía Liquida/métodos , Imidazoles/análisis , Soluciones Oftálmicas/análisis , Antiinfecciosos/análisis , Compuestos de Benzalconio/normas , Cromatografía Liquida/instrumentación , Soluciones Oftálmicas/química , Estándares de Referencia , Reproducibilidad de los Resultados , Tecnología Farmacéutica/métodos
4.
Electrophoresis ; 22(11): 2143-9, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11504045

RESUMEN

The use of salting-out effect for the off-line preconcentration of charged analytes in capillary electrophoresis is demonstrated for the first time. Using benzalkonium chloride (BAK) as model compound, a mixture of cationic surfactants consisting of even-numbered alkylbenzyl quaternary ammonium homologues (C8-C18), the addition of appropriate amounts of sodium chloride and acetonitrile in the sample solution (2 mL sample volume) was found to be capable of providing ca. 40-fold enhancement in detection sensitivity. In addition to affording a preconcentrating effect due to the extraction of BAK in the smaller volume water-miscible organic solvent phase (acetonitrile), the organic solvent also serves to improve the peak area and shape of the longer chain surfactants. Optimal experimental conditions, such as volume of acetonitrile and concentration of sodium chloride, for the preconcentration of BAK with good preconcentration factors and reproducibility were investigated. The usefulness of the present method was demonstrated for the improved determination of BAK present in commercially available industrial and pharmaceutical products.


Asunto(s)
Compuestos de Benzalconio/análisis , Electroforesis Capilar/métodos , Acetonitrilos , Antiinfecciosos Locales/análisis , Compuestos de Benzalconio/normas , Desinfectantes/análisis , Preparaciones Farmacéuticas/análisis , Conservadores Farmacéuticos/análisis , Cloruro de Sodio , Solventes , Agua
5.
Int J Legal Med ; 104(5): 281-4, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1723622

RESUMEN

DNA recovered from a condom found at a crime scene appeared undigestible with restriction enzymes, preventing characterization by Southern blot and polymorphic probe hybridization. Several chemical substances used in the processing and treatment of condoms were tested for inhibitory action of restriction enzymes. In particular dibenzalkonium chloride appeared to promote enzyme inhibition at very low concentrations. The effectiveness of treatments to restore cleavage of sample DNA in the presence of such contaminants is discussed.


Asunto(s)
Southern Blotting/normas , Dispositivos Anticonceptivos Masculinos/normas , Desinfectantes/normas , Mapeo Restrictivo , Semen , Compuestos de Benzalconio/normas , Sangre , Southern Blotting/métodos , Diálisis , Ácido Dioctil Sulfosuccínico/normas , Estudios de Evaluación como Asunto , Amplificación de Genes , Humanos , Azufre/normas
8.
Appl Microbiol ; 29(6): 713-6, 1975 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-808163

RESUMEN

A semiautomated method has been developed for quantitatively assaying the activity of detergent disinfectants. Automation permitted a high level of reproducibility, which in turn allowed a meaningful comparison between the activities of some types of quaternary ammonium compounds.


Asunto(s)
Compuestos de Benzalconio/normas , Evaluación de Medicamentos/métodos , Automatización , Compuestos de Benzalconio/farmacología , Relación Dosis-Respuesta a Droga , Evaluación de Medicamentos/instrumentación , Escherichia coli/efectos de los fármacos , Pseudomonas aeruginosa/efectos de los fármacos , Staphylococcus/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...