RESUMEN
The recently CE-marked continuous real-time glucose monitoring (rtCGM) solution Accu-Chek® (AC) SmartGuide Solution was developed to enable people with diabetes mellitus (DM) to proactively control their glucose levels using predictive technologies. The comprehensive solution consists of three components that harmonize well with each other. The CGM device is composed of a sensor applicator and a glucose sensor patch whose data are transferred to the connected smartphone by Bluetooth® Low Energy. The user interface of the CGM solution is powered by the AC SmartGuide app delivering current and past glucose metrics, and the AC SmartGuide Predict app providing a glucose prediction suite enabled by artificial intelligence (AI). This article describes the innovative CGM solution.
Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Humanos , Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Diabetes Mellitus/sangre , Aplicaciones Móviles , Teléfono Inteligente , Inteligencia Artificial , Control Glucémico/instrumentación , Diseño de Equipo , Monitoreo Continuo de GlucosaRESUMEN
AIMS: To conduct a systematic review and meta-analysis, within the Coordinating Research and Evidence for Medical Devices (CORE-MD) project, evaluating CE-marked high-risk devices for glucose management. MATERIALS AND METHODS: We identified interventional and observational studies evaluating the efficacy and safety of eight automated insulin delivery (AID) systems, two implantable insulin pumps, and three implantable continuous glucose monitoring (CGM) devices. We meta-analysed randomized controlled trials (RCTs) comparing AID systems with other treatments. RESULTS: A total of 182 studies published between 2009 and 2024 were included, comprising 166 studies on AID systems, six on insulin pumps, and 10 on CGM devices; 26% reported industry funding; 18% were pre-market; 37% had a comparator group. Of the studies identified, 29% were RCTs, 24% were non-randomized trials, and 47% were observational studies. The median (interquartile range) sample size was 48 (28-102), age 34.8 (14-44.2) years, and study duration 17.5 (12-26) weeks. AID systems lowered glycated haemoglobin by 0.5 percentage points (absolute mean difference [MD] = -0.5; 21 RCTs; I2 = 86%) and increased time in target range for sensor glucose level by 13.4 percentage points (MD = 13.4; 14 RCTs; I2 = 90%). At least one safety outcome was assessed in 71% of studies. CONCLUSIONS: High-risk devices for glucose monitoring or insulin dosing, in particular AID systems, improve glucose control safely, but evidence on diabetes-related end-organ damage is lacking due to short study durations. Methodological heterogeneity highlights the need for developing standards for future pre- and post-market investigations of diabetes-specific high-risk medical devices.
Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Sistemas de Infusión de Insulina , Insulina , Adolescente , Adulto , Humanos , Adulto Joven , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/efectos adversos , Automonitorización de la Glucosa Sanguínea/instrumentación , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Control Glucémico/instrumentación , Control Glucémico/métodos , Hipoglucemia/sangre , Hipoglucemia/inducido químicamente , Hipoglucemia/diagnóstico , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Bombas de Infusión Implantables/efectos adversos , Insulina/administración & dosificación , Insulina/efectos adversos , Sistemas de Infusión de Insulina/efectos adversos , Estudios Observacionales como Asunto , Ensayos Clínicos Controlados Aleatorios como AsuntoRESUMEN
Aim The efficacy of hybrid closed-loop systems (HCLs) in managing glycemic control in pregnant women with type 1 diabetes remains inadequately characterized. We evaluated the use of the Medtronic Minimed 780G HCLs. METHODS: The retrospective observational study analyzed the glycemic and perinatal outcomes of pregnant women using the HCLs, followed at our tertiary centre. Independent t-tests were employed to compare data among trimesters based on pre-pregnancy HbA1c. The associations between glycemic parameters and perinatal outcomes were explored using Spearman rho. RESULTS: Among the 21 women (age: 33.5 ± 4.2 years, diabetes duration: 21.2 ± 7.6 years, pre-pregnancy HbA1c 7.0 ± 1.1 % (52.9 ± 11.9 mmol/mol)) time in range (pTIR, 63-140 mg/dl; 3.5-7.8 mmol/l) increased progressively throughout pregnancy (trimesters: first: 64.0 ± 9.0 %; second:71.3 ± 11.8 %; third: 75.7 ± 8.1 %). Simultaneously, mean sensor glucose decreased (trimesters: first: 130 ± 10.4 mg/dl (7.2 ± 0.6 mmol/l); second: 120.9 ± 13.4 mg/dl (6.7 ± 0.7 mmol/l); third: 117.3 ± 9.1 mg/dl (6.5 ± 0.5 mmol/l)). Although a majority of women achieved the target pTIR until the third trimester, this did not consistently prevent the delivery of a large-for-gestational-age baby. Notably, one ketoacidosis event occurred, and there were no reported instances of severe hypoglycemia. CONCLUSION: Use of the Minimed 780G HCLs enabled the attainment of recommended pregnancy glycemic targets for most women with type 1 diabetes in a real-world setting.
Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Control Glucémico , Sistemas de Infusión de Insulina , Embarazo en Diabéticas , Humanos , Embarazo , Femenino , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Embarazo en Diabéticas/sangre , Embarazo en Diabéticas/tratamiento farmacológico , Embarazo en Diabéticas/epidemiología , Adulto , Estudios Retrospectivos , Glucemia/análisis , Control Glucémico/métodos , Control Glucémico/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Automonitorización de la Glucosa Sanguínea/instrumentación , Insulina/administración & dosificación , Insulina/uso terapéutico , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Hemoglobina Glucada/análisis , Resultado del Embarazo/epidemiología , Hipoglucemia/prevención & control , Hipoglucemia/epidemiología , Hipoglucemia/inducido químicamente , Recién NacidoRESUMEN
The effectiveness of a hybrid closed-loop (HCL) system in improving glycemic control is unclear in Japanese individuals. Therefore, we assessed the effect impact of the MiniMed 770G HCL system on glycemic control in this population. This prospective, single-center, 24-week observational study (registration number: UMIN000047394) enrolled 23 individuals with type 1 diabetes mellitus using the Medtronic MiniMed 640G system. The primary endpoint was the improvement in time in the range of 70-180 mg/dL after transitioning to the MiniMed 770G HCL system. We observed an increase in time in range (from 64.1 [55.8-69.5] to 70.9 [67.1-74.4] %, interquartile range 25-75%, p < 0.001) and a decrease in glycated hemoglobin level (from 7.4 [7.0-7.9] to 7.1 [6.8-7.4] %, p = 0.003). There was a significant reduction in time above the range (181-250 mg/dL: 25.8 [20.9-28.6] to 19.5 [17.1-22.1] %, p < 0.001; >251 mg/dL: 8.7 [4.0-13.0] to 4.7 [3.6-9.1] %, p < 0.001). Time below the range remained unchanged (54-69 mg/dL: 1.8 [0.4-2.4] to 2.1 [0.4-3.9] %, p = 0.24; <54 mg/dL: 0.2 [0.0-1.0] to 0.5 [0.1-1.3] %, p = 0.14). In a subgroup of 12 patients with a high HCL implementation rate, the basal insulin infusion decreased immediately after mealtime insulin administration and increased after approximately 120 minutes. The ratings from questionnaires assessing treatment burden, satisfaction, and quality of life remained unchanged. The MiniMed 770G HCL system improved glycemic control and optimized insulin delivery, particularly in patients with high implementation rates.
Asunto(s)
Diabetes Mellitus Tipo 1 , Control Glucémico , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Pueblos del Este de Asia , Hemoglobina Glucada , Control Glucémico/instrumentación , Control Glucémico/métodos , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Insulina/uso terapéutico , Japón , Estudios Prospectivos , Resultado del TratamientoAsunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Embarazo en Diabéticas , Humanos , Embarazo , Femenino , Sistemas de Infusión de Insulina/efectos adversos , Glucemia/análisis , Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Insulina/administración & dosificación , Adulto , Embarazo en Diabéticas/tratamiento farmacológico , Embarazo en Diabéticas/sangre , Hipoglucemiantes/administración & dosificación , Automonitorización de la Glucosa Sanguínea/instrumentación , Control Glucémico/instrumentación , Control Glucémico/efectos adversosRESUMEN
BACKGROUND: Self-monitoring of glucose is an essential component of type 1 diabetes (T1D) management. In recent years, continuous glucose monitoring (CGM) has provided an alternative to daily fingerstick testing for the optimisation of insulin dosing and general glucose management in people with T1D. While studies have been conducted to evaluate the impact of CGM on clinical outcomes in the US, Europe and Australia, there are limited data available for low- and middle-income countries (LMICs) and further empirical evidence is needed to inform policy decision around their use in these countries. METHODS: This trial was designed as a pragmatic, parallel-group, open-label, multicentre, three-arm, randomised (1:1:1) controlled trial of continuous or periodic CGM device use versus standard of care in people with T1D in South Africa and Kenya. The primary objective of this trial will be to assess the impact of continuous or periodic CGM device use on glycaemic control as measured by change from baseline glycosylated haemoglobin (HbA1c). Additional assessments will include clinical outcomes (glucose variation, time in/below/above range), safety (adverse events, hospitalisations), quality of life (EQ-5D, T1D distress score, Glucose Monitoring Satisfaction Survey for T1D), and health economic measures (incremental cost-effectiveness ratios, quality adjusted life years). DISCUSSION: This trial aims to address the substantial evidence gap on the impact of CGM device use on clinical outcomes in LMICs, specifically South Africa and Kenya. The trial results will provide evidence to inform policy and treatment decisions in these countries. TRIAL REGISTRATION: NCT05944731 (Kenya), July 6, 2023; NCT05944718 (South Africa), July 13, 2023.
Asunto(s)
Diabetes Mellitus Tipo 1 , Hemoglobina Glucada , Humanos , Glucemia/análisis , Monitoreo Continuo de Glucosa/instrumentación , Análisis Costo-Beneficio , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Control Glucémico/instrumentación , Hipoglucemiantes/uso terapéutico , Ciencia de la Implementación , Insulina/uso terapéutico , Kenia , Estudios Multicéntricos como Asunto , Ensayos Clínicos Pragmáticos como Asunto , Calidad de Vida , Sudáfrica , Resultado del TratamientoRESUMEN
BACKGROUND: Automated insulin delivery (AID) devices have shown to be a promising treatment to improve glycemic control in patients with type 1 diabetes mellitus (T1DM). However, its efficacy in pregnant women with T1DM remains uncertain. METHODS: PubMed, Scopus, Cochrane Central and ClinicalTrials.gov were systematically searched for randomized controlled trials (RCTs) comparing AID to standard care (SC), defined as use of sensor-augmented pump and multiple daily insulin injections. Outcomes included time in range (TIR), nocturnal TIR, time in hypoglycemic and hyperglycemic ranges, among others. Sensitivity and trial sequential analyses (TSA) were performed. PROSPERO ID: CRD42023474398. RESULTS: We included five RCTs with a total of 236 pregnant women, of whom 117 (50.6%) received AID. There was a significant increase in nocturnal TIR (mean difference [MD] 12.69%; 95% CI 8.74-16.64; p < 0.01; I2 = 0%) and a decrease in glucose variability (standard deviation of glucose; MD -2.91; 95% CI -5.13 to -0.69; p = 0.01; I2 = 0%). No significant differences were observed for TIR, HBGI, LGBI, mean glucose and time spent in hyperglycemia and hypoglycemia. Regarding TSA, the statistical significance obtained in nocturnal TIR was conclusive and with minimal risk of a type I error. CONCLUSION: Our findings suggest that AID systems can significantly improve nocturnal glycemic control and potentially reduce glycemic variability in pregnant women with T1DM, with no effect in the risk of hypoglycemia and hyperglycemia compared with current insulin treatments.
Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Ensayos Clínicos Controlados Aleatorios como Asunto , Adulto , Femenino , Humanos , Embarazo , Glucemia/metabolismo , Glucemia/análisis , Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Control Glucémico/métodos , Control Glucémico/instrumentación , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Embarazo en Diabéticas/tratamiento farmacológico , Embarazo en Diabéticas/sangre , Resultado del TratamientoAsunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 2 , Medicare , Aplicaciones Móviles , Humanos , Diabetes Mellitus Tipo 2/sangre , Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Anciano , Estados Unidos , Masculino , Femenino , Control Glucémico/instrumentación , Anciano de 80 o más AñosRESUMEN
We aimed to evaluate the utility of the FreeStyle Libre 2 device for reducing time below range level 1 and level 2 compared with the Freestyle Libre device (without alarms) in people with type 1 diabetes mellitus. We conducted longitudinal observational follow-up study of a cohort of 100 people with type 1 diabetes mellitus who had switched from FreeStyle Libre to FreeStyle Libre 2 as part of routine clinical practice. Three months after switching to FreeStyle Libre 2, compared with results with FreeStyle Libre, there were a significant improvements in time below range level 1 (p = 0.02) and level 2 (p <0.001), time in range (p <0.001), time above range level 1 (p = 0.002), glucose management indicator (p= 0.04) and mean glucose (p= 0.04) during follow-up. Furthermore there was a significant direct association between age and change in TIR with a coefficient of 0.23, and a significant inverse association between age and change in TAR-1 with a coefficient of 0.11. Switching to a flash glucose monitoring system with alarms improves time below range, time in range and coefficient of variation in people with type 1 diabetes mellitus.
Asunto(s)
Biomarcadores , Automonitorización de la Glucosa Sanguínea , Glucemia , Alarmas Clínicas , Diabetes Mellitus Tipo 1 , Hipoglucemia , Valor Predictivo de las Pruebas , Humanos , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/metabolismo , Masculino , Femenino , Adulto , Factores de Tiempo , Hipoglucemia/sangre , Hipoglucemia/diagnóstico , Hipoglucemia/inducido químicamente , Persona de Mediana Edad , Biomarcadores/sangre , Estudios Longitudinales , Control Glucémico/instrumentación , Estudios de Seguimiento , Diseño de Equipo , Hipoglucemiantes/uso terapéutico , Adulto Joven , Reproducibilidad de los ResultadosRESUMEN
Introducción: La diabetes en pacientes con COVID-19 se asocia a mayor morbilidad y mortalidad. El aislamiento social podría dificultar el acceso a la atención e insumos médicos. Nuestro objetivo fue describir el control glucémico durante la pandemia y los recursos médicos y tecnológicos disponibles. Métodos: Estudio retrospectivo, descriptivo, analítico y transversal. Se analizaron los resultados de una encuesta realizada a pacientes diabéticos del Hospital de Pediatría Juan P. Garrahan. Se indagó infección por coronavirus, proximidad geográfica, control metabólico, cobertura, insumos y conectividad. Resultados: No se informaron casos de COVID-19. El 52,9% vivía a más de dos horas de viaje. El 95,7% realizó 4 o más glucemias diarias, el 12,8% estuvo en el rango glucémico ideal de 70-140 mg%, el 75,2% entre 140-250 mg% y el 12% por encima de 250 mg%. El 6,8% presentó cetosis y el 3,4% hipoglucemia severa. El 17,9% refirió dificultades para conseguir insumos. Todos poseían internet, 12% con limitaciones. El 10% que vivía a 2 o más horas del hospital estuvo en rango ideal vs. 28% de los que vivían más cerca (p=0,02). El 96,4% de los que retiraron insumos de su cobertura social o provincial alcanzaron un control metabólico aceptable (70-250 mg%) vs. 79,5% de los que lo hicieron en el hospital. (p=0,0002). Conclusiones: La mayoría presentó un control metabólico aceptable. La distancia y las dificultades de disponibilidad de insumos, se asociaron a peor control glucémico. La conectividad y recursos tecnológicos son limitados (AU)
Introduction: In patients with diabetes who are infected with COVID-19, the latter is associated with increased morbidity and mortality. Social isolation may complicate access to care and medical supplies. Our aim was to describe glycemic control during the pandemic and the medical and technological resources available. Methods: Retrospective, descriptive, analytical, and cross-sectional study. The results of a survey conducted in patients with diabetes seen at Hospital de Pediatría Juan P. Garrahan were analyzed. Coronavirus infection, geographic proximity to the hospital, metabolic control, healthcare coverage, supplies, and connectivity were investigated. Results: No cases of COVID-19 were reported. Overall, 52.9% lived more than two hours travel from the hospital; 95.7% performed four or more daily capillary blood glucose measurements; in 12.8% blood glucose was within the target range of 70-140 mg%, in 75.2% it was between 140-250 mg%, and in 12% above 250 mg%; 6.8% had ketosis and 3.4% severe hypoglycemia. Overall, 17.9% reported difficulties in obtaining medical supplies. All had internet access, although 12% with limitations. Ten percent of the patients who lived 2 or more hours from the hospital had blood glucose levels within the target range vs. 28% of those who lived closer (p=0.02); 96.4% of those who received diabetes supplies from their social or provincial insurance achieved acceptable metabolic control (70-250 mg%) vs. 79.5% of those who did so from the hospital (p=0,0002). Conclusions: The majority of patients had acceptable metabolic control. Distance and difficulties in the availability of supplies were associated with worse glycemic control. Connectivity and technological resources are limited (AU)
Asunto(s)
Humanos , Lactante , Preescolar , Niño , Adolescente , Telemedicina , Diabetes Mellitus , Acceso a Medicamentos Esenciales y Tecnologías Sanitarias , Control Glucémico/instrumentación , COVID-19/complicaciones , Enfermedad Crónica , Estudios Transversales , Encuestas y Cuestionarios , Estudios RetrospectivosRESUMEN
BACKGROUND: The possible advantage of hybrid closed-loop therapy (i.e., artificial pancreas) over sensor-augmented pump therapy in very young children with type 1 diabetes is unclear. METHODS: In this multicenter, randomized, crossover trial, we recruited children 1 to 7 years of age with type 1 diabetes who were receiving insulin-pump therapy at seven centers across Austria, Germany, Luxembourg, and the United Kingdom. Participants received treatment in two 16-week periods, in random order, in which the closed-loop system was compared with sensor-augmented pump therapy (control). The primary end point was the between-treatment difference in the percentage of time that the sensor glucose measurement was in the target range (70 to 180 mg per deciliter) during each 16-week period. The analysis was conducted according to the intention-to-treat principle. Key secondary end points included the percentage of time spent in a hyperglycemic state (glucose level, >180 mg per deciliter), the glycated hemoglobin level, the mean sensor glucose level, and the percentage of time spent in a hypoglycemic state (glucose level, <70 mg per deciliter). Safety was assessed. RESULTS: A total of 74 participants underwent randomization. The mean (±SD) age of the participants was 5.6±1.6 years, and the baseline glycated hemoglobin level was 7.3±0.7%. The percentage of time with the glucose level in the target range was 8.7 percentage points (95% confidence interval [CI], 7.4 to 9.9) higher during the closed-loop period than during the control period (P<0.001). The mean adjusted difference (closed-loop minus control) in the percentage of time spent in a hyperglycemic state was -8.5 percentage points (95% CI, -9.9 to -7.1), the difference in the glycated hemoglobin level was -0.4 percentage points (95% CI, -0.5 to -0.3), and the difference in the mean sensor glucose level was -12.3 mg per deciliter (95% CI, -14.8 to -9.8) (P<0.001 for all comparisons). The time spent in a hypoglycemic state was similar with the two treatments (P = 0.74). The median time spent in the closed-loop mode was 95% (interquartile range, 92 to 97) over the 16-week closed-loop period. One serious adverse event of severe hypoglycemia occurred during the closed-loop period. One serious adverse event that was deemed to be unrelated to treatment occurred. CONCLUSIONS: A hybrid closed-loop system significantly improved glycemic control in very young children with type 1 diabetes, without increasing the time spent in hypoglycemia. (Funded by the European Commission and others; ClinicalTrials.gov number, NCT03784027.).
Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Control Glucémico/instrumentación , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Páncreas Artificial , Algoritmos , Glucemia/análisis , Niño , Preescolar , Estudios Cruzados , Diseño de Equipo , Femenino , Hemoglobina Glucada/análisis , Control Glucémico/métodos , Humanos , Hiperglucemia/diagnóstico , Lactante , MasculinoRESUMEN
BACKGROUND: The COVID-19 pandemic has led to the rapid implementation of remote care delivery in type 1 diabetes. We studied current modes of care delivery, healthcare professional experiences and impact on insulin pump training in type 1 diabetes care in the United Kingdom (UK). METHODS: The UK Diabetes Technology Network designed a 48-question survey aimed at healthcare professionals providing care in type 1 diabetes. RESULTS: One hundred and forty-three healthcare professionals (48% diabetes physicians, 52% diabetes educators and 88% working in adult services) from approximately 75 UK centres (52% university hospitals, 46% general and community hospitals), responded to the survey. Telephone consultations were the main modality of care delivery. There was a higher reported time taken for video consultations versus telephone (p < 0.001). Common barriers to remote consultations were patient familiarity with technology (72%) and access to patient device data (67%). We assessed the impact on insulin pump training. A reduction in total new pump starts (73%) and renewals (61%) was highlighted. Common barriers included patient digital literacy (61%), limited healthcare professional experience (46%) and time required per patient (44%). When grouped according to size of insulin pump service, pump starts and renewals in larger services were less impacted by the pandemic compared to smaller services. CONCLUSION: This survey highlights UK healthcare professional experiences of remote care delivery. While supportive of virtual care models, a number of factors highlighted, especially patient digital literacy, need to be addressed to improve virtual care delivery and device training.
Asunto(s)
COVID-19/epidemiología , Diabetes Mellitus Tipo 1/terapia , Personal de Salud , Automanejo/educación , Telemedicina , Adulto , Actitud del Personal de Salud , Tecnología Biomédica/educación , Automonitorización de la Glucosa Sanguínea/instrumentación , Atención a la Salud/métodos , Atención a la Salud/organización & administración , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/epidemiología , Control Glucémico/instrumentación , Personal de Salud/organización & administración , Personal de Salud/psicología , Personal de Salud/estadística & datos numéricos , Humanos , Sistemas de Infusión de Insulina , Pandemias , Educación del Paciente como Asunto/métodos , Educación del Paciente como Asunto/organización & administración , Consulta Remota/métodos , Consulta Remota/organización & administración , Automanejo/métodos , Automanejo/psicología , Encuestas y Cuestionarios , Telemedicina/métodos , Telemedicina/organización & administración , Telemedicina/estadística & datos numéricos , Reino Unido/epidemiologíaRESUMEN
AIM: To compare accuracy, efficacy and acceptance of implantable and transcutaneous continuous glucose monitoring (CGM) systems. METHODS: In a randomized crossover trial we compared 12 weeks with Eversense implantable sensor (EVS) and 12 weeks with Dexcom G5 transcutaneous sensor (DG5) in terms of accuracy, evaluated as Mean Absolute Relative Difference (MARD) vs capillary glucose (SMBG), time of CGM use, adverse events, efficacy (as HbA1c, time in range, time above and below range) and psychological outcomes evaluated with Diabetes Treatment Satisfaction Questionnaire (DTSQ), Glucose Monitoring Satisfaction Survey (GMSS), Hypoglycemia Fear Survey (HFS2), Diabetes Distress Scale (DDS). RESULTS: 16 subjects (13 males, 48.8 ± 10.1 years, HbA1c 55.8 ± 7.9 mmol/mol, mean ± SD) completed the study. DG5 was used more than EVS [percentage of use 95.7 ± 3.6% vs 93.5 ± 4.3% (p = 0.02)]. MARD was better with EVS (12.2 ± 11.5% vs. 13.1 ± 14.7%, p< 0.001). No differences were found in HbA1c. While using EVS time spent in range increased and time spent in hyperglycemia decreased, but these data were not confirmed by analysis of retrofitted data based on SMBG values. EVS reduced perceived distress, without significant changes in other psychological outcomes. CONCLUSIONS: CGM features may affect glycemic control and device acceptance.
Asunto(s)
Diabetes Mellitus Tipo 1/sangre , Control Glucémico/instrumentación , Aceptación de la Atención de Salud , Adulto , Automonitorización de la Glucosa Sanguínea/efectos adversos , Automonitorización de la Glucosa Sanguínea/instrumentación , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Femenino , Hemoglobina Glucada/análisis , Hemoglobina Glucada/metabolismo , Control Glucémico/efectos adversos , Humanos , Implantes Experimentales/efectos adversos , Insulina/administración & dosificación , Sistemas de Infusión de Insulina/efectos adversos , Italia , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del TratamientoRESUMEN
Para que os fármacos possam ser comercializados economicamente, a sua escala de produção deve ser aumentada para atender à demanda do mercado. Atualmente, a maior parte dos fármacos são sintetizados em processos batelada que possuem limitações quanto à eficiência de mistura, temperatura e pressão. O uso de microrreatores surge como alternativa na indústria químico-farmacêutica, aumentando a eficiência dos processos de maneira segura. Ferramentas utilizadas no segmento computacional multidisciplinar teórico, como o DFT (Density Functional Theory), podem prever e compreender o comportamento das reações químicas, podendo ter grande utilidade na síntese de novos fármacos economizando tempo, investimento e reduzindo a geração de resíduos. A diabetes mellitus é uma doença de caráter epidêmico, que a cada ano vem aumentando o número de casos. O emprego de fármacos derivados das glitazonas no tratamento de diabetes mellitus tipo 2 é recomendado devido ao excelente controle glicêmico que esta classe de fármacos oferece. Neste trabalho, foi sintetizada a Rosiglitazona, um fármaco derivado das glitazonas, que auxilia no tratamento da diabetes mellitus tipo 2, sendo estudadas duas rotas de síntese distintas, que foram otimizadas com o intuito de maximizar o rendimento de seus intermediários, obtendo a Rosiglitazona com pureza de cerca de 94%. Foi realizada, para os intermediários, aqui denominados, 1R, 2R2 e 3R2 a síntese one-pot e para os intermediários 1R, 2R1 e 3R2 foi realizada a transposição do processo usual em batelada para fluxo contínuo no microrreator, com rendimentos de até 93%. Com o auxílio da química quântica computacional, a reação de síntese do intermediário 1R, foi elucidada teoricamente e determinadas as grandezas termodinâmicas (ΔH, ΔG e ΔS) no estado de transição, que foram comparadas com os valores experimentais, sendo constatada uma boa concordância, com desvio máximo de 14%
In order for drugs to be commercialized economically, their production scale must be increased to meet market demand. Currently, most drugs are synthesized in batch processes that have limitations in terms of mixing efficiency, temperature and pressure. The use of microreactors appears as an alternative in the chemical-pharmaceutical industry, increasing the efficiency of the synthesis processes in a safe way. Tools used in the theoretical multidisciplinary computational segment, such as DFT (Density Functional Theory), can predict and understand the behavior of chemical reactions, and can be very useful in the synthesis of new drugs, saving time, investment and reducing waste generation. Diabetes mellitus is an epidemic disease that has been increasing the number of cases every year. The use of drugs derived from glitazones in the treatment of type 2 diabetes mellitus is recommended due to the excellent glycemic control that this class of drugs offers. In this work, Rosiglitazone, a drug derived from glitazones, which helps in the treatment of type 2 diabetes mellitus, was synthesized. Two different synthetic routes were studied and optimized in order to maximize the yield of its intermediates, obtaining Rosiglitazone with purity of about 94%. One-pot synthesis was performed to 1R, 2R2 and 3R2 intermediates, and the transposition from the usual batch process to continuous flow in microreactor was performed to 1R, 2R1 and 3R2 intermediates, with yields of up to 93%. With the aid of computational quantum chemistry, the intermediate 1R synthesis reaction was theoretically elucidated and the thermodynamic properties were determined (ΔH, ΔG and ΔS) in the transition state, which were compared with the experimental results, obtaining good agreement, with a maximum deviation of 14%
Asunto(s)
Preparaciones Farmacéuticas/provisión & distribución , Industria Farmacéutica/organización & administración , Rosiglitazona/análisis , Biofarmacia/clasificación , Reacciones Químicas , Diabetes Mellitus Tipo 2/patología , Teoría Funcional de la Densidad , Control Glucémico/instrumentación , Inversiones en Salud/clasificaciónRESUMEN
Abstract Faced with the increase of type 2 Diabetes mellitus (DM2) and the failure in treatment, questions have been raised about the clinical situation of these patients. The present study analyzes the prevalence of hypertension and obesity in DM2 patients. Data were collected through interviews and anamnesis of 16 participants. After the meetings, in which capillary glycemia and blood pressure were measured, the participants received guidance about glycemic monitoring, blood pressure control and changes in lifestyle. Approximately 75% of the participants were women with average age of 65 years, 87.5% were sedentary, 18.75% smoked and/or used alcoholic beverages and none performed regular blood glucose monitoring. The initial blood glucose average was 148 mg/ dL and finally decreased to 133 mg/dL. There was no significant difference in blood pressure levels. Regarding the body mass index, 89.4% of the patients were above normal standards and 100% had altered waist circumference values. There is a need for studies like this in order to promote educational practices for health and disease control, highlighting the importance of multidisciplinary teams and the pharmaceutical professional, since non-adherence to blood glucose monitoring, also associated with hypertension and obesity, can interfere with the individual's clinical condition.
Asunto(s)
Humanos , Masculino , Femenino , Anciano , Pacientes/clasificación , Prevalencia , Diabetes Mellitus Tipo 2/diagnóstico , Hipertensión/patología , Obesidad , Preparaciones Farmacéuticas/administración & dosificación , Índice de Masa Corporal , Presión Arterial , Control Glucémico/instrumentación , Estilo de VidaRESUMEN
Abstract The present study aims to investigate the impacts of cigarette smoking (CS) and water-pipe smoking (WPS) on the visceral adiposity index (VAI), hematological characteristics, and glycemic tolerance in Iraqi healthy smokers. A total of 528 healthy males from different locations of Baghdad city were allocated to three groups; nonsmokers (176), cigarette smokers (178), and WP smokers (174). Baseline characteristics, anthropometric and hematological markers and were reported. Glycemic control was evaluated using the glucose tolerance test. The evidence of elevated VAI, disrupted hematological markers, and impaired glucose tolerance was significantly (P<0.001) different compared with non-smokers and related to the duration of smoking. The impacts of WPS seem to be significantly greater than CS in certain parameters (hemoglobin, hematocrit, methemoglobin, and 2-hour glucose tolerance values). In conclusion, CS and WPS negatively impacted body fat distribution, glucose tolerance, and hematological markers. There is a positive association between the rate of smoking and obesity, glycemic intolerance in both groups
Asunto(s)
Humanos , Masculino , Adulto , Asociación , Tabaquismo/complicaciones , Distribución de la Grasa Corporal , Adiposidad , Fumar en Pipa de Agua/efectos adversos , Control Glucémico/instrumentación , Hemoglobinas/análisis , Fumadores , Prueba de Tolerancia a la Glucosa/instrumentación , Irak/etnologíaRESUMEN
Importance: There is no consensus on the impact of the 2020 COVID-19 pandemic lockdown on glycemic control in children and adolescents with type 1 diabetes (T1D) in the US. Aim: To determine the impact of the pandemic lockdown of March 15th through July 6th, 2020 on glycemic control after controlling for confounders. Subjects and Methods: An observational study of 110 subjects of mean age 14.8 ± 4.9 years(y), [male 15.4 ± 4.0y, (n=57); female 14.1 ± 3.8y, (n=53), p=0.07] with T1D of 6.31 ± 4.3y (95% CI 1.0-19.7y). Data were collected at 1-4 months before the lockdown and 1-4 months following the lifting of the lockdown at their first post-lockdown clinic visit. Results: There was no significant change in A1c between the pre- and post-pandemic lockdown periods, 0.18 ± 1.2%, (95% CI -0.05 to 0.41), p=0.13. There were equally no significant differences in A1c between the male and female subjects, -0.16 ± 1.2 vs -0.19 ± 1.2%, p=0.8; insulin pump users and non-pump users, -0.25 ± 1.0 vs -0.12 ± 1.4%, p=0.5; and pubertal vs prepubertal subjects, 0.18 ± 1.3 vs -0.11 ± 0.3%, p=0.6. The significant predictors of decrease in A1c were pre-lockdown A1c (p<0.0001) and the use of CGM (p=0.019). The CGM users had significant reductions in point-of-care A1c (0.4 ± 0.6%, p=0.0012), the CGM-estimated A1c (p=0.0076), mean glucose concentration (p=0.022), a significant increase in sensor usage (p=0.012), with no change in total daily dose of insulin (TDDI). The non-CGM users had significantly increased TDDI (p<0.0001) but no change in HbA1c, 0.06 ± 1.8%, p=0.86. Conclusions: There was no change in glycemic control during the pandemic lockdown of 2020 in US children.
Asunto(s)
COVID-19/epidemiología , Diabetes Mellitus Tipo 1/sangre , Control Glucémico , Cuarentena , Adolescente , Factores de Edad , Glucemia/metabolismo , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , COVID-19/prevención & control , Niño , Control de Enfermedades Transmisibles/organización & administración , Diabetes Mellitus Tipo 1/epidemiología , Diabetes Mellitus Tipo 1/terapia , Femenino , Hemoglobina Glucada/metabolismo , Control Glucémico/instrumentación , Control Glucémico/métodos , Historia del Siglo XXI , Humanos , Insulina/administración & dosificación , Sistemas de Infusión de Insulina , Masculino , Pandemias , Cuarentena/organización & administración , Estudios Retrospectivos , Estados Unidos/epidemiologíaRESUMEN
With the development of mobile communication technology, smartphones have been used in point-of-care technologies (POCTs) as an important part of telemedicine. Using a multidisciplinary design principle coupling electrical engineering, software development, synthetic biology, and optogenetics, the investigators developed a smartphone-controlled semiautomatic theranostic system that regulates blood glucose homeostasis in diabetic mice in an ultraremote-control manner. The present chapter describes how the investigators tailor-designed the implant architecture "HydrogeLED," which is capable of coharboring a designer-cell-carrying alginate hydrogel and wirelessly powered far-red light LEDs. Using diabetes mellitus as a model disease, the in vivo expression of insulin or human glucagon-like peptide 1 (shGLP-1) from HydrogeLED implants could be controlled not only by pre-set ECNU-TeleMed programs, but also by a custom-engineered Bluetooth-active glucometer in a semiautomatic and glycemia-dependent manner. As a result, blood glucose homeostasis was semiautomatically maintained in diabetic mice through the smartphone-controlled semiautomatic theranostic system. By combining digital signals with optogenetically engineered cells, the present study provides a new method for the integrated diagnosis and treatment of diseases.