Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.766
Filtrar
1.
Molecules ; 29(13)2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38998918

RESUMEN

The Brassicaceae family, commonly referred to as cruciferous plants, is globally cultivated and consumed, with the Brassica genus being particularly renowned for its functional components. These vegetables are rich sources of nutrients and health-promoting phytochemicals, garnering increased attention in recent years. This study presents a comprehensive microscopic, chromatographic, and spectroscopic characterization of Brassica napus L. seeds from Kazakhstan aimed at elucidating their morphological features and chemical composition. Microscopic analysis revealed distinct localization of flavonoids, total lipids, and alkaloids. High-performance thin-layer chromatography (HPTLC) analysis of seed extracts demonstrated a complex chemical profile with significant quantities of non-polar compounds in the hexane extracts. Additionally, methanolic extracts revealed the presence of diverse chemical compounds, including alkaloids, flavonoids, and glucosinolates. The chemical composition exhibited varietal differences across different Brassica species, with B. napus L. seeds showing higher concentrations of bioactive compounds. Furthermore, liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-QToF-MS) analysis provided insights into the chemical composition, with sinapine isomers, feruloyl, and sinapoyl choline derivatives as major compounds in the seeds. This study contributes to a better understanding of the chemical diversity and quality control methods' approximations of B. napus L. seeds, highlighting their importance in functional food and nutraceutical applications.


Asunto(s)
Brassica napus , Semillas , Brassica napus/química , Semillas/química , Extractos Vegetales/química , Extractos Vegetales/análisis , Fitoquímicos/análisis , Fitoquímicos/química , Cromatografía en Capa Delgada/métodos , Cromatografía Líquida de Alta Presión/métodos , Flavonoides/análisis , Flavonoides/química , Alcaloides/análisis , Alcaloides/química , Cromatografía Liquida/métodos , Espectrometría de Masas/métodos , Glucosinolatos/análisis , Glucosinolatos/química
2.
Artículo en Inglés | MEDLINE | ID: mdl-38824745

RESUMEN

A novel and highly sensitive high-performance thin-layer chromatographic (HPTLC) method was developed and validated to quantify a combination of five pharmaceutical mixtures spiked to human plasma. The compounds comprised Amlodipine (AML) along with five angiotensin II receptor antagonist drugs (AIIRAs), namely Olmesartan (OLM), Telmisartan (TLM), Candesartan (CAN), Losartan (LOS), and Irbesartan (IRB). HPTLC was performed on silica gel 60 F254 plates using a mobile phase of Toluene: ethyl acetate: methanol: acetone: acetic acid (6:1.5:1:0.5:1, v/v/v/v/v). In a pioneering move, a reflectance/fluorescence detection mode was employed to identify two concurrently administered drugs at different pH levels for the first time. This method utilized the same chromatographic system, incorporating a specific measurement for AML at a neutral medium to achieve its maximum fluorescence at a 360 nm excitation wavelength, and measuring emission using a 540 nm optical filter. The process involved obtaining a very low fluorescence response from AIIRA. Subsequently, to enhance AIIRA's fluorescence, the plate was sprayed with perchloric acid to transition to a strong acidic medium, ultimately attaining the maximum fluorescence of AIIRA using various excitation wavelengths and a 400 nm emission filter. Through this strategic process, we could optimize the fluorescence signals of both drugs, thereby elevating the sensitivity of detection for this drug combination. AML demonstrated a linear range of 18-300 ng/band, while AIIRAs drugs exhibited a linear range of 6-150 ng/band. The method satisfied the International Conference on Harmonization (ICH) criteria for recovery, precision, repeatability, and robustness, showcasing exceptional sensitivity. The approach was successfully applied to quantify AML and AIIRAs drugs in both bulk drug and plasma samples, achieving high recovery percentages and minimal standard deviations.


Asunto(s)
Amlodipino , Densitometría , Límite de Detección , Amlodipino/sangre , Humanos , Cromatografía en Capa Delgada/métodos , Concentración de Iones de Hidrógeno , Reproducibilidad de los Resultados , Densitometría/métodos , Modelos Lineales , Antagonistas de Receptores de Angiotensina/sangre , Espectrometría de Fluorescencia/métodos
3.
Molecules ; 29(11)2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38893351

RESUMEN

The 5-heterocyclic 2-(2,4-dihydroxyphenyl)-1,3,4-thiadiazoles were obtained as potential biologically active compounds. Lipophilicity is one of the most important physicochemical properties of compounds and was already taken into account during the drug candidates design and development. The lipophilicity of compounds was determined using the computational (log P) and chromatography (log kw, RMw) methods. The experimental ones included the reverse-phase column high performance liquid chromatography RP (HPLC) with C8, C18, phosphatidylcholine (IAM), and cholesterol stationary phases and the thin layer chromatography (RP-HPTLC) with C8 and C18 stationary phases and various organic modifiers under the isocratic conditions. Descriptive statistics, correlation, and PCA analyses were used to compare the obtained results. For lipophilicity estimation of the tested compounds by HPTLC, dioxane and MeOH seem to be particularly beneficial as organic modifiers. The chromatographic lipophilicity parameters log kw (RMw) were well correlated and highly redundant (85%) compared with those calculated. Most compounds possess lipophilicity parameters within the recommended range for drug candidates.


Asunto(s)
Interacciones Hidrofóbicas e Hidrofílicas , Tiadiazoles , Tiadiazoles/química , Cromatografía Líquida de Alta Presión/métodos , Cromatografía en Capa Delgada/métodos , Simulación por Computador , Cromatografía de Fase Inversa/métodos
4.
Sud Med Ekspert ; 67(3): 39-44, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38887070

RESUMEN

The aim of the work is to study the nature of the distribution of 2-A-4.6-DNP in the organisms of warm-blooded animals with intragastric administration of a toxicant. The study was carried out using the methods of TLC, UV-Visible spectroscopy, and GC-MS using derivatives of 2-A-4.6-DNP. Male Wistar rats at the age of 4 months were considered as a model of the body of a warm-blooded animal. An oily suspension of 2-A-4.6-DNF was administered intragastrically in an amount of three times the LD50. Extraction of the target substance from the biomaterial was carried out by double infusion (30 minutes each) with a mixture of acetone-acetonitrile (1:1), the amount of the mixture exceeded the weight of the biomaterial by 2 times. Extractions were purified by TLC method using «Sorbfil¼ plates and acetone-chloroform (7: 3) mobile phase. Preliminary identification was carried out at the same time using a standard substance. Confirmatory identification was carried out by the absorption of dimethylformamide eluates in «SF-2000¼, as well as by the retention time and mass spectra of the major compound of the corresponding chromatographic peaks after GC-MS analysis. The quantitative content was determined spectrophotometrically, in DMF, by optical density at the analytical wavelength (490 nm). 2-Amino-4.6-dinitrophenol was found unchanged in the blood and in all the studied hollow and parenchymal organs of poisoned rats. The largest amount of 2-amino-4.6-dinitrophenol (mg/100 g) was found in the stomach walls (199.39±25.43) and stomach contents (143.14±22.63), a significant amount of the substance was found in the heart (33.49±3.66), skeletal muscles (30.70±2.64), as well as in the spleen (24.30±1.96).


Asunto(s)
Toxicología Forense , Cromatografía de Gases y Espectrometría de Masas , Ratas Wistar , Animales , Ratas , Toxicología Forense/métodos , Masculino , Cromatografía de Gases y Espectrometría de Masas/métodos , Cromatografía en Capa Delgada/métodos , Distribución Tisular
5.
J Chromatogr A ; 1726: 464972, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38744184

RESUMEN

The effect of internal and external magnetic fields on the separation of antifungal drugs by centrifugal acceleration thin-layer chromatography was reported for the first time. External and internal magnetic fields were applied using neodymium magnets and CoFe2O4@SiO2 ferromagnetic nanoparticles. Separation of ketoconazole and clotrimazole was performed using a mobile phase consisting of n-hexane, ethyl acetate, ethanol, and ammonia (2.0:2.0:0.5:0.2, v/v). The influence of the magnetic field on the entire chromatographic system led to changes in the properties of the stationary and mobile phases and the analytes affecting the retention factor, shape, and width of the separated rings. The extent of this impact depended on the structure of the analyte and the type and intensity of the magnetic field. In the presence of the external magnetic field, there were more significant changes in the chromatographic parameters of the drugs, especially the width of the separated rings, and ketoconazole was more affected than clotrimazole. The changes are conceivably due to the effect of the magnetic field on the analyte distribution between the stationary and mobile phases, which is also caused by the possibility of the magnetic field affecting the viscosity, surface tension, and surface free energy between the stationary and mobile phases.


Asunto(s)
Antifúngicos , Cetoconazol , Campos Magnéticos , Cromatografía en Capa Delgada/métodos , Antifúngicos/análisis , Antifúngicos/química , Antifúngicos/aislamiento & purificación , Cetoconazol/química , Cetoconazol/análisis , Clotrimazol/química , Clotrimazol/análisis , Centrifugación/métodos , Dióxido de Silicio/química
6.
J Pharm Biomed Anal ; 246: 116224, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38759321

RESUMEN

Cardiovascular diseases, including fatal myocardial infarctions from atheromatous plaques, are the primary global mortality cause. Detecting stenotic atheromatous plaques is possible through coronary angiography, but vulnerable plaques with eccentric remodeling are undetectable with current diagnostic methods. Addressing this challenge, our group developed a radiopharmaceutical drug targeting vascular cell adhesion molecule 1 (VCAM-1), radiolabeled with technetium-99m. Given the absence of a monograph in the European Pharmacopoeia, and in order to draft the investigational medicinal product documentation, analytical methods had to be validated by high performance liquid chromatography (HPLC) and thin layer chromatography (TLC) to determine the radiochemical purity (RCP) of 99mTc-cAbVCAM1-5. This study therefore presents the results of the validation of analytical methods obtained in this context. The method validation followed the European Association of Nuclear Medicine (EANM) recommendations adapted from ICH Q2(R1), ensuring conformity with specificity, accuracy, repeatability and intermediate precision, linearity, robustness, quantification limit (LoQ), and range criteria. Regarding the results of specificity, both HPLC and TLC methods demonstrated excellent separation of 99mTc-cAbVCAM1-5 from impurities 99mTcO4-. Accuracy results indicated recovery percentages within the range of 99.52-101.40% for the HPLC and 99.51-101.97% for TLC, ensuring reliable measurements for each concentration of 99mTcO4-. Precision of the methods was validated by assessing repeatability and intermediate precision. Linearity was determined over the usual concentrations range and the correlation coefficient was greater than 0.99 for both methods. The limit of quantification was measured by diluting the 99mTcO4- to obtain a signal-to-noise ratio of around 10:1. Under these conditions, we obtained an LOQ of 2.10 MBq/mL for HPLC and 2Mbq/mL for TLC. In conclusion, the analytical methods developed in this study comply with EANM recommendations. This therefore allows us to correctly assess the radiochemical purity of 99mTc-cAbVCAM1-5, a new radiotracer targeting inflammation in vulnerable plaques.


Asunto(s)
Radiofármacos , Cromatografía Líquida de Alta Presión/métodos , Cromatografía en Capa Delgada/métodos , Radiofármacos/química , Radiofármacos/análisis , Reproducibilidad de los Resultados , Tecnecio/química , Tecnecio/análisis , Compuestos de Organotecnecio/química , Compuestos de Organotecnecio/análisis
7.
Folia Med (Plovdiv) ; 66(2): 255-263, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38690822

RESUMEN

INTRODUCTION: In the period between 1997 and 2010, sibutramine-containing drugs were widely prescribed for obesity and over-weight management. Due to safety concerns, in 2010 all medicines containing sibutramine were urgently withdrawn from the USA and European pharmaceutical market. Although sibutramine is no longer available in pharmaceutical products, there have been numerous reports of mislabeled weight-loss dietary supplements containing sibutramine.


Asunto(s)
Depresores del Apetito , Ciclobutanos , Suplementos Dietéticos , Ciclobutanos/análisis , Suplementos Dietéticos/análisis , Cromatografía en Capa Delgada/métodos , Depresores del Apetito/análisis , Humanos
8.
Sci Rep ; 14(1): 10025, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693137

RESUMEN

The coronavirus-2 has led to a global pandemic of COVID-19 with an outbreak of severe acute respiratory syndrome leading to worldwide quarantine measures and a rise in death rates. The objective of this study is to propose a green, sensitive, and selective densitometric method to simultaneously quantify remdesivir (REM) in the presence of the co-administered drug linezolid (LNZ) and rivaroxaban (RIV) in spiked human plasma. TLC silica gel aluminum plates 60 F254 were used as the stationary phase, and the mobile phase was composed of dichloromethane (DCM): acetone (8.5:1.5, v/v) with densitometric detection at 254 nm. Well-resolved peaks have been observed with retardation factors (Rf) of 0.23, 0.53, and 0.72 for REM, LNZ, and RIV, respectively. A validation study was conducted according to ICH Q2 (R1) Guidelines. The method was rectilinear over the concentration ranges of 0.2-5.5 µg/band, 0.2-4.5 µg/band and 0.1-3.0 µg/band for REM, LNZ and RIV, respectively. The sensitivities of REM, LIN, and RIV were outstanding, with quantitation limits of 128.8, 50.5, and 55.8 ng/band, respectively. The approach has shown outstanding recoveries ranging from 98.3 to 101.2% when applied to pharmaceutical formulations and spiked human plasma. The method's greenness was assessed using Analytical Eco-scale, GAPI, and AGREE metrics.


Asunto(s)
Adenosina Monofosfato/análogos & derivados , Alanina/análogos & derivados , Antivirales , Tratamiento Farmacológico de COVID-19 , COVID-19 , SARS-CoV-2 , Humanos , Antivirales/sangre , SARS-CoV-2/efectos de los fármacos , COVID-19/sangre , Cromatografía en Capa Delgada/métodos , Análisis Costo-Beneficio , Alanina/sangre , Linezolid/sangre
9.
Food Chem ; 452: 139481, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38723565

RESUMEN

As a hypertoxic natural toxin, the risk of Microcystin-leucine-arginine (MC-LR) residues in Bellamya aeruginosa deserves more attention. Herein, employing the conventional thin-layer chromatography (TLC) technology and a novel surface-enhanced Raman scattering (SERS) substrate, a TLC-SERS chip was fabricated for the purification and quantitative detection of MC-LR in complex samples. The substrate exhibited excellent SERS performance with an enhancement factor of 6.6 × 107, a low detection limit of 2.27 × 10-9 mM for MC-LR, excellent uniformity and reproducibility, as well as a wide linear range. With the application of TLC, the MC-LR was efficiently purified and the concentration was increased to >3 times. Ultimately, recovery rates fluctuated between 93.28% and 101.66% were obtained from the TLC-SERS chip. On balance, the TLC-SERS chip has a robust capacity for achieving rapid and stable quantitative detection of MC-LR, which promises to improve the efficiency of food safety monitoring.


Asunto(s)
Toxinas Marinas , Microcistinas , Plata , Espectrometría Raman , Microcistinas/análisis , Espectrometría Raman/métodos , Toxinas Marinas/análisis , Cromatografía en Capa Delgada/métodos , Plata/química , Contaminación de Alimentos/análisis , Oro/química , Nanopartículas del Metal/química , Límite de Detección , Imidazoles , Zeolitas
10.
Sci Rep ; 14(1): 10613, 2024 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-38719831

RESUMEN

Chlorogenic acid (CA) is an effective ingredient that can strengthen immunity during following the COVID-19 era. The current cost of CA is high owing to its complex purification process and low yield (approximately 2%). In this study, a one-step path orthogonal experiment was designed based on the results from Gauss calculation, which consisted of acidity, coordination, and hydrolysis in molecules. The optimized extraction conditions were 60 â„ƒ, 60 min, 1:20 liquid ratio, and 40% ethanol in a nitrogen atmosphere controlled using a device of our own design, which led to CA yields of up to 6.35% from potato leaves. The purified CA was analyzed using high-performance liquid chromatography, thin-layer chromatography, ultraviolet-visible spectroscopy, and molecular fluorescence. This accurate and reproducible method can not only be used to obtain high yields of CA but can also be used for the quality control of active plant products and their isomers.


Asunto(s)
Ácido Clorogénico , Hojas de la Planta , Solanum tuberosum , Ácido Clorogénico/análisis , Solanum tuberosum/química , Hojas de la Planta/química , Cromatografía Líquida de Alta Presión/métodos , Cromatografía en Capa Delgada/métodos
11.
Anal Bioanal Chem ; 416(15): 3519-3532, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38656365

RESUMEN

The masking of specific effects in in vitro assays by cytotoxicity is a commonly known phenomenon. This may result in a partial or complete loss of effect signals. For common in vitro assays, approaches for identifying and quantifying cytotoxic masking are partly available. However, a quantification of cytotoxicity-affected signals is not possible. As an alternative, planar bioassays that combine high-performance thin layer chromatography with in vitro assays, such as the planar yeast estrogen screen (p-YES), might allow for a quantification of cytotoxically affected signals. Affected signals form a typical ring structure with a supressed or completely lacking centre that results in a double peak chromatogram. This study investigates whether these double peaks can be used for fitting a peak function to extrapolate the theoretical, unaffected signals. The precision of the modelling was evaluated for four individual peak functions, using 42 ideal, undistorted peaks from estrogenic model compounds in the p-YES. Modelled ED50-values from bisphenol A (BPA) experiments with cytotoxically disturbed signals were 13 times higher than for the apparent data without compensation for cytotoxicity (320 ± 63 ng versus 24 ± 17 ng). This finding has a high relevance for the modelling of mixture effects according to concentration addition that requires unaffected, complete dose-response relationships. Finally, we applied the approach to results of a p-YES assay on leachate samples of an elastomer material used in water engineering. In summary, the fitting approach enables the quantitative evaluation of cytotoxically affected signals in planar in vitro assays and also has applications for other fields of chemical analysis like distorted chromatography signals.


Asunto(s)
Bioensayo , Bioensayo/métodos , Cromatografía en Capa Delgada/métodos , Fenoles/toxicidad , Fenoles/análisis , Fenoles/química , Compuestos de Bencidrilo/toxicidad , Compuestos de Bencidrilo/análisis , Compuestos de Bencidrilo/química , Estrógenos/análisis , Estrógenos/toxicidad
12.
Biomed Chromatogr ; 38(7): e5867, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38558037

RESUMEN

Fourteen donepezil-like acetylcholinesterase (AChE) inhibitors from our library were analyzed using reversed-phase thin-layer chromatography to assess their lipophilicity and blood-brain barrier permeability. Compounds possessed N-benzylpiperidine and N,N-diarylpiperazine moieties connected via a short carboxamide or amine linker. Retention parameters RM 0, b, and C0 were considered as the measures of lipophilicity. Besides, logD of the investigated compounds was determined chromatographically using standard compounds with known logPow and logD values at pH 11. Experimentally obtained lipophilicity parameters correlated well with in silico generated results, and the effect of the nature of the linker between two pharmacophores and substituents on the arylpiperazine part of the molecule was observed. As a result of drug-likeness analysis, both Lipinski's rule of five and Veber's rule parameters were determined, suggesting that examined compounds could be potential candidates for further drug development. Principal component analysis was performed to obtain an insight into a grouping of compounds based on calculated structural descriptors, experimentally obtained values of lipophilicity, and AChE inhibitory activity.


Asunto(s)
Inhibidores de la Colinesterasa , Cromatografía de Fase Inversa , Donepezilo , Interacciones Hidrofóbicas e Hidrofílicas , Piperidinas , Cromatografía en Capa Delgada/métodos , Inhibidores de la Colinesterasa/química , Inhibidores de la Colinesterasa/farmacología , Cromatografía de Fase Inversa/métodos , Donepezilo/química , Donepezilo/farmacología , Piperidinas/química , Indanos/química , Barrera Hematoencefálica/metabolismo , Análisis de Componente Principal
13.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 55(2): 425-432, 2024 Mar 20.
Artículo en Chino | MEDLINE | ID: mdl-38645843

RESUMEN

Objective: To establish quality standards for Liuwei Nengxiao pills, to optimize the quality control method, and to provide references for the quality control of Liuwei Nengxiao pills. Methods: Chebula, dried ginger, and Tibetan liqueur root in Liuwei Nengxiao pills of different batch numbers were analyzed by thin layer chromatography (TLC). Then, the content of chrysophanol in the preparation was determined by high performance liquid chromatography (HPLC). Furthermore, a series of methodological validation, including the investigation of the linear relationship, precision, stability, and reproducibility and sample recovery test, were performed to verify the reliability of the results. Results: The TLC identification method was easy to perform and demonstrated high specificity, clear spots, and good separation effect. In addition, the negative controls showed no interference. The HPLC method showed high accuracy. The results of methodological validation showed that the peak area of chrysophanol had a good linear relationship (r2=1.0) in the range of 0.06-0.80 µg, presenting good precision (with the relative standard deviation being lower than 2.0%), good stability and reproducibility (with the relative standard deviation being lower than 1.0%), and an average recovery rate of 100.8%. Conclusion: TLC and HPLC are easy to perform, showing high accuracy and reproducibility. The quality standards established are scientific, reasonable, stable, and feasible, providing references for the quality control of Liuwei Nengxiao pills.


Asunto(s)
Antraquinonas , Medicamentos Herbarios Chinos , Medicina Tradicional Tibetana , Control de Calidad , Medicamentos Herbarios Chinos/normas , Medicamentos Herbarios Chinos/química , Cromatografía Líquida de Alta Presión/métodos , Medicina Tradicional Tibetana/normas , Cromatografía en Capa Delgada/métodos , Reproducibilidad de los Resultados
14.
Int J Mol Sci ; 25(8)2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38673898

RESUMEN

The absolute configuration and stability of two thianthrene chiral sulfoxides has been determined by means of X-ray single-crystal structure determinations. The analyses and configurations allow verification that the diastereomeric sulfoxides are stable in solution and are not interconverting, which has been suggested in some studies of sulfoxides. The two thianthrene sulfoxides have slightly different Rf values, which allowed their separation using flash chromatography on silica. The spots run back-to-back, which posed a challenge for their separation. The pure, separated compounds in solution remain as separate, single spots on a Thin Layer Chromatography (TLC) plate.


Asunto(s)
Sulfóxidos , Estereoisomerismo , Sulfóxidos/química , Cristalografía por Rayos X/métodos , Modelos Moleculares , Cromatografía en Capa Delgada/métodos , Fenantrenos/química , Estructura Molecular
15.
Molecules ; 29(8)2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38675702

RESUMEN

The goal of this study was to apply the principles of analytical quality by design (AQbD) to the analytical method for determining the radiochemical purity (PQR) of the radiopharmaceutical sodium iodide 131I oral solution, utilizing thin-layer chromatography (TLC) with a radio-TLC scanner, which also enables the evaluation of product quality. For AQbD, the analytical target profile (ATP), critical quality attributes (CQA), risk management, and the method operable design region (MODR) were defined through response surface methodology to optimize the method using MINITAB® 19 software. This study encompassed the establishment of a control strategy and the validation of the method, including the assessment of selectivity, linearity, precision, robustness, detection limit, quantification limit, range, and the stability of the sample solution. Under the experimental conditions, the method parameters of the TLC scanner were experimentally demonstrated and optimized with an injection volume of 3 µL, a radioactive concentration of 10 mCi/mL, and a carrier volume of 40 µL. Statistical analysis confirmed the method's selectivity for the 131I iodide band Rf of 0.8, a radiochemical impurity IO3- Rf of 0.6, a linearity from 6.0 to 22.0 mCi/mL, and an intermediate precision with a global relative standard deviation (RSD) of 0.624%. The method also exhibited robustness, with a global RSD of 0.101%, a detection limit of 0.09 mCi/mL, and a quantification limit of 0.53 Ci/mL, meeting the prescribed range and displaying stability over time (at 0, 2, and 20 h) with a global RSD of 0.362%, resulting in consistent outcomes. The development of a method based on AQbD facilitated the creation of a design space and an operational space, with comprehensive knowledge of the method's characteristics and limitations. Additionally, throughout all operations, compliance with the acceptance criteria was verified. The method's validity was confirmed under the established conditions, making it suitable for use in the manufacturing process of sodium iodide 131I and application in nuclear medicine services.


Asunto(s)
Radioisótopos de Yodo , Radiofármacos , Yoduro de Sodio , Cromatografía en Capa Delgada/métodos , Radiofármacos/química , Radiofármacos/análisis , Radioisótopos de Yodo/análisis , Yoduro de Sodio/química , Administración Oral , Reproducibilidad de los Resultados
16.
Anal Methods ; 16(16): 2449-2455, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38563199

RESUMEN

Carotenoids are yellow, orange, and red pigments commonly found in plants. In leaves, these molecules are essential for photosynthesis, but they also play a major role in plant growth and development. Efficiently monitoring concentrations of specific carotenoids in plant tissues could help to explain plant responses to environmental stressors, infection and disease, fertilization, and other conditions. Previously, Raman methods have been used to demonstrate a correlation between plant fitness and the carotenoid content of leaves. Due to solvatochromatic effects and structural similarities within the carotenoid family, current Raman spectroscopy techniques struggle to assign signals to specific carotenoids with certainty, complicating the determination of amounts of individual carotenoids present in a sample. In this work, we use thin layer chromatography-Raman spectroscopy, or TLC-Raman, to identify and quantify carotenoids extracted from tomato leaves. These quick and accurate methods could be applied to study the relationship between pigment content and a number of factors affecting plant health.


Asunto(s)
Carotenoides , Hojas de la Planta , Solanum lycopersicum , Espectrometría Raman , Hojas de la Planta/química , Espectrometría Raman/métodos , Cromatografía en Capa Delgada/métodos , Carotenoides/análisis , Carotenoides/química , Solanum lycopersicum/química , Solanum lycopersicum/metabolismo , Pigmentos Biológicos/análisis , Pigmentos Biológicos/química
17.
J Agric Food Chem ; 72(17): 10106-10116, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38629120

RESUMEN

The authentication of ingredients in formulas is crucial yet challenging, particularly for constituents with comparable compositions but vastly divergent efficacy. Rehmanniae Radix and its derivatives are extensively utilized in food supplements, which contain analogous compositions but very distinct effects. Rehmanniae Radix, also a difficult-to-detect herbal ingredient, was chosen as a case to explore a novel HPTLC-QDa MS technique for the identification of herbal ingredients in commercial products. Through systematic condition optimization, including thin layer and mass spectrometry, a stable and reproducible HPTLC-QDa MS method was established, which can simultaneously detect oligosaccharides and iridoids. Rehmannia Radix and its processed products were then analyzed to screen five markers that could distinguish between raw and prepared Rehmannia Radix. An HPTLC-QDa-SIM method was further established for formula detection by using the five markers and validated using homemade prescriptions and negative controls. Finally, this method was applied to detect raw and prepared Rehmannia Radix in 12 commercial functional products and supplements.


Asunto(s)
Medicamentos Herbarios Chinos , Rehmannia , Rehmannia/química , Cromatografía en Capa Delgada/métodos , Medicamentos Herbarios Chinos/química , Cromatografía Líquida de Alta Presión/métodos , Raíces de Plantas/química , Suplementos Dietéticos/análisis , Espectrometría de Masas/métodos , Oligosacáridos/análisis , Oligosacáridos/química , Iridoides/análisis , Iridoides/química
18.
Methods Mol Biol ; 2790: 427-438, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38649585

RESUMEN

The biological role of lipids goes far beyond the formation of a structural membrane bilayer platform for membrane proteins and controlling fluxes across the membranes. For example, in photosynthetic thylakoid membranes, lipids occupy well-defined binding niches within protein complexes and determine the structural organization of membrane proteins and their function by controlling generic physicochemical membrane properties. In this chapter, two-dimensional thin-layer chromatography (2D TLC) and gas chromatography (GC) techniques are presented for quantitative analysis of lipid classes and fatty acids in thylakoid membranes. In addition, lipid extraction methods from isolated thylakoid membranes and leaves are described together with a procedure for the derivatization of fatty acids to fatty acid methyl esters (FAME) that is required for GC analysis.


Asunto(s)
Ácidos Grasos , Fotosíntesis , Tilacoides , Tilacoides/metabolismo , Cromatografía en Capa Delgada/métodos , Cromatografía de Gases/métodos , Ácidos Grasos/metabolismo , Ácidos Grasos/química , Lípidos de la Membrana/metabolismo , Lípidos de la Membrana/química , Hojas de la Planta/metabolismo , Hojas de la Planta/química , Lípidos/química , Lípidos/aislamiento & purificación , Lípidos/análisis
19.
Anal Methods ; 16(19): 2997-3006, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38687148

RESUMEN

α-Amylase/trypsin inhibitor proteins (ATI) are discussed as possible triggers for non-celiac gluten sensitivity. The potential of high-performance thin-layer chromatography (HPTLC) was studied for the first time to analyse the inhibitory properties of ATIs from flour of wheat, spelt, and einkorn. Inhibition by each flour of the digestive enzymes trypsin or α-amylase was determined by the reduction of released metabolisation products in comparison to non-digested flour, and positive (acarbose) and negative (water) controls. Firstly, amylolysis was carried out in miniaturized form on the HPTLC surface (HPTLC-nanoGIT) after in-vial pre-incubation of the amylase with the inhibitors from flour. α-Amylase inhibition was evident via the reduction of released saccharides, as analysed by normal phase HPTLC. A strong influence of the flour matrix on the assay results (individual saccharides) was evident, caused by an increased amylolysis of further polysaccharides present, making HPTLC analysis more reliable than currently used spectrophotometric sum value assays. The detection and visualization of such matrix influence helps to understand the problems associated with spectrophotometric assays. Only maltotriose was identified as a reliable marker of the amylolysis. The highest α-amylase inhibition and thus the lowest saccharide response was detected for maltotriose in refined spelt, whereas the lowest α-amylase inhibition and thus the highest saccharide response was detected for maltotriose in refined wheat. A comparison of refined and whole grain flours showed no clear trend in the responses. Secondly, trypsin inhibition and proteolysis were performed in-vial, and any inhibition was evident via the reduction of released peptides, analysed by reversed-phase HPTLC. Based on the product pattern of the proteolysis, einkorn and whole wheat showed the highest trypsin inhibition, whereas refined wheat and refined spelt showed the lowest inhibition. Advantageously, HPTLC analysis provided important information on changes in individual saccharides or peptides, which was more reliable and sustainable than spectrophotometric in-vial assays (only sum value) or liquid column chromatography analysis (targeting only the ATI proteins).


Asunto(s)
Triticum , Inhibidores de Tripsina , alfa-Amilasas , Triticum/química , Cromatografía en Capa Delgada/métodos , alfa-Amilasas/antagonistas & inhibidores , alfa-Amilasas/análisis , Inhibidores de Tripsina/análisis , Inhibidores de Tripsina/farmacología , Proteínas de Plantas/análisis , Harina/análisis
20.
Ann Pharm Fr ; 82(4): 718-726, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38485086

RESUMEN

OBJECTIVES: A synergic antihistamine, cough suppressant, and decongestant combination of chlorpheniramine, dextromethorphan, and phenylephrine is used to treat acute respiratory infections caused by seasonal viruses. The effective qualitative and quantitative methods require the simultaneous measurement of a ternary combination in the pharmaceutical syrup dosage form. Therefore, a new, simple, fast and robust high performance thin layer chromatographic (HPTLC) method has been developed and validated for chlorpheniramine maleate (CPM), dextromethorphan hydrobromide (DEXO) and phenylephrine hydrochloride (PE). MATERIAL AND METHODS: The chromatographic separation was carried out on precoated aluminium plates with silica gel 60 F254 as the stationary phase. Mobile phase used was chloroform: methanol: ammonia (2.5:7.5:0.3, v/v/v) for proper separation. The detection was carried out at 270nm wavelength in absorbance mode. Developed method was validated as per International Council for Harmonization (ICH) Q2 (R1) guideline. RESULTS: The linearity range is 400 to 1400ng/band for CPM, 3000 to 11500ng/band for DEXO and 1000 to 3500ng/band for PE with correlation coefficient ≥ 0.995. The consistent lower values of relative standard deviation (RSD, %) for precision and robustness study indicate the method reliability. The percent recovery ranged from 97.82 to 102.03% indicates the good accuracy of the method. CONCLUSION: The proposed method was complying for the analytical method validation parameters suggested by the ICH Q2 (R1) guideline. The method was found to be simple, rapid and reliable for the simultaneous estimation of CPM, DEXO and PE from its pharmaceutical syrup dosage form. The method was successfully applied to quantify these analytes from the several pharmaceutical syrup dosage form.


Asunto(s)
Clorfeniramina , Dextrometorfano , Combinación de Medicamentos , Fenilefrina , Dextrometorfano/análisis , Clorfeniramina/análisis , Fenilefrina/análisis , Cromatografía en Capa Delgada/métodos , Reproducibilidad de los Resultados , Antitusígenos/análisis , Límite de Detección , Antagonistas de los Receptores Histamínicos H1/análisis , Soluciones Farmacéuticas/análisis , Cromatografía Líquida de Alta Presión/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...