Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.374
Filtrar
1.
Medicine (Baltimore) ; 103(19): e38096, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38728473

RESUMEN

To investigate whether direct-acting antiviral (DAA) treatment affected liver fibrosis testing, including transient elastography (TE), aspartate aminotransferase-to-platelet ratio index (APRI), and Fibrosis-4 (FIB-4) index, after establishing a sustained virological response for 24 weeks. This prospective cohort study was conducted between October 1, 2019, and September 30, 2020, at Rajavithi Hospital, Bangkok, Thailand. All the patients had significant liver fibrosis (TE ≥ 7.0 kPa) at baseline and completed 12 weeks of DAA therapy. After achieving SVR, liver stiffness measurements were repeated for at least 24 weeks. The primary outcome was a > 30% improvement in TE score at the end of the study compared to baseline. A multivariate logistic regression model was used to identify the parameters associated with the primary outcome. Temporal changes in APRI and FIB-4 indices from baseline to 24 weeks posttreatment were also examined. A total of 110 chronic HCV patients were included in our cohort, of which 57 (52.3%) achieved the primary outcome. The median TE decreased from 15.05 (8.76-23.68) kPa at pretreatment to 9.60 (6.50-14.40) kPa at 24 weeks posttreatment (P < .001). Those who had a baseline TE ≥ 9.5 kPa had higher odds of meeting the primary outcome, and this remained significant after adjusting for age, sex, baseline body mass index, underlying diabetes mellitus, HCV genotype 3, baseline laboratory levels, and treatment regimens (OR 3.04; 95% CI 1.22-7.60, P = .017). Similar to TE, the median APRI and FIB-4 index displayed a considerable reduction from baseline to 24 weeks after successful therapy. Modern DAA treatment has been associated with considerable improvement in liver stiffness measured by TE in chronic HCV patients who achieve SVR, with roughly 52% of patients experiencing a reduction of > 30% in TE over 24 weeks posttreatment compared to baseline. This probably indicates early fibrosis regression, although the effect of resolution of inflammation after treatment completion cannot be ruled out.


Asunto(s)
Antivirales , Diagnóstico por Imagen de Elasticidad , Hepatitis C Crónica , Cirrosis Hepática , Respuesta Virológica Sostenida , Humanos , Hepatitis C Crónica/tratamiento farmacológico , Hepatitis C Crónica/sangre , Masculino , Femenino , Antivirales/uso terapéutico , Persona de Mediana Edad , Estudios Prospectivos , Cirrosis Hepática/tratamiento farmacológico , Cirrosis Hepática/virología , Adulto , Hígado/patología , Hígado/diagnóstico por imagen , Aspartato Aminotransferasas/sangre , Anciano , Resultado del Tratamiento
2.
Medicine (Baltimore) ; 103(19): e38159, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38728476

RESUMEN

Shear wave elastography (SWE) is a noninvasive method for measuring organ stiffness. Liver stiffness measured using SWE reflects hepatic congestion in patients with heart failure (HF). However, little is known about the use of SWE to assess other organ congestions. This study aimed to evaluate the utility of SWE for assessing not only the liver but also thyroid congestion in patients with HF. This prospective study included 21 patients with HF who have normal thyroid lobes (age: 77.0 ±â€…11.0, men: 14). Thyroid and liver stiffness were measured by SWE using the ARIETTA 850 ultrasonography system (Fujifilm Ltd., Tokyo, Japan). SWE of the thyroid was performed on B-mode ultrasonography; a target region was identified within a region of interest. SWE was performed in each lobe of the thyroid gland. Five measurements were taken at the same location and the averages were recorded for comparison. We investigated the relationship between SWE for evaluating thyroid stiffness and the clinical characteristics of patients with HF. SWE of the thyroid was significantly correlated with SWE of the liver (R = 0.768, P < .001), thyroid stimulation hormone (R = 0.570, P = .011), free thyroxine (R = 0.493, P = .032), estimated right atrial pressure (RAP; R = 0.468, P = .033), and composite congestion score (R = 0.441, P = .045). SWE may be useful for evaluating thyroid stiffness and assessing the degree of thyroid congestion. Thyroid congestion may reflect the elevation of RAP and cause thyroid dysfunction through organ congestion.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Insuficiencia Cardíaca , Glándula Tiroides , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Masculino , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/complicaciones , Femenino , Anciano , Estudios Prospectivos , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/fisiopatología , Hígado/diagnóstico por imagen , Hígado/fisiopatología , Anciano de 80 o más Años , Enfermedades de la Tiroides/diagnóstico por imagen , Enfermedades de la Tiroides/complicaciones , Persona de Mediana Edad
3.
Gynecol Endocrinol ; 40(1): 2352139, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38733361

RESUMEN

OBJECTIVE: The main purpose of this systematic review and meta-analysis was to investigate the diagnostic value of ultrasound elastography in the evaluation of polycystic ovary syndrome (PCOS). METHODS: A comprehensive and methodical investigation was carried out in the databases of PubMed, EMBASE, Cochrane, Scopus, Web of Science, and China National Knowledge Infrastructure, covering the entire duration of these databases until October 18, 2023. The primary purpose of this research was to evaluate and contrast ovarian tissue elasticity in people with and without PCOS. The elasticity of ovarian tissue was quantified using standardized mean difference (SMD). RESULTS: A total of eight studies were ultimately selected for systematic evaluation and meta-analysis. Five studies used shear wave elastography (SWE) as a diagnostic tool, and it was discovered that women with PCOS had higher levels of ovarian shear wave elasticity than their healthy counterparts. The SMD was determined to be 1.86 kilopascal (95% CI: 1.27 to 2.44). Three studies were conducted using strain elastography (SE) to compare the ovarian strain ratio of patients with PCOS to that of a healthy control group. The SMD for the PCOS group was 2.07 (95% CI: 1.79 to 2.34), which indicated that the ovarian strain ratio was significantly higher in that group. CONCLUSION: This systematic review and meta-analysis found that women with PCOS had stiffer ovarian tissue than women without the disorder. Ultrasound elastography may provide clinicians with value beyond 2D ultrasound in the diagnosis of PCOS.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Síndrome del Ovario Poliquístico , Síndrome del Ovario Poliquístico/diagnóstico por imagen , Síndrome del Ovario Poliquístico/fisiopatología , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Ovario/diagnóstico por imagen , Elasticidad
4.
Opt Lett ; 49(10): 2817-2820, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748169

RESUMEN

Alteration in the elastic properties of biological tissues may indicate changes in the structure and components. Acoustic radiation force optical coherence elastography (ARF-OCE) can assess the elastic properties of the ocular tissues non-invasively. However, coupling the ultrasound beam and the optical beam remains challenging. In this Letter, we proposed an OCE method incorporating homolateral parallel ARF excitation for measuring the elasticity of the ocular tissues. An acoustic-optic coupling unit was established to reflect the ultrasound beam while transmitting the light beam. The ARF excited the ocular tissue in the direction parallel to the light beam from the same side of the light beam. We demonstrated the method on the agar phantoms, the porcine cornea, and the porcine retina. The results show that the ARF-OCE method can measure the elasticity of the cornea and the retina, resulting in higher detection sensitivity and a more extensive scanning range.


Asunto(s)
Córnea , Diagnóstico por Imagen de Elasticidad , Fantasmas de Imagen , Tomografía de Coherencia Óptica , Diagnóstico por Imagen de Elasticidad/métodos , Animales , Porcinos , Córnea/diagnóstico por imagen , Córnea/fisiología , Tomografía de Coherencia Óptica/métodos , Elasticidad , Retina/diagnóstico por imagen , Retina/fisiología
5.
Radiology ; 311(2): e233136, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38742971

RESUMEN

Background MR elastography (MRE) has been shown to have excellent performance for noninvasive liver fibrosis staging. However, there is limited knowledge regarding the precision and test-retest repeatability of stiffness measurement with MRE in the multicenter setting. Purpose To determine the precision and test-retest repeatability of stiffness measurement with MRE across multiple centers using the same phantoms. Materials and Methods In this study, three cylindrical phantoms made of polyvinyl chloride gel mimicking different degrees of liver stiffness in humans (phantoms 1-3: soft, medium, and hard stiffness, respectively) were evaluated. Between January 2021 and January 2022, phantoms were circulated between five different centers and scanned with 10 MRE-equipped clinical 1.5-T and 3-T systems from three major vendors, using two-dimensional (2D) gradient-recalled echo (GRE) imaging and/or 2D spin-echo (SE) echo-planar imaging (EPI). Similar MRE acquisition parameters, hardware, and reconstruction algorithms were used at each center. Mean stiffness was measured by a single observer for each phantom and acquisition on a single section. Stiffness measurement precision and same-session test-retest repeatability were assessed using the coefficient of variation (CV) and the repeatability coefficient (RC), respectively. Results The mean precision represented by the CV was 5.8% (95% CI: 3.8, 7.7) for all phantoms and both sequences combined. For all phantoms, 2D GRE achieved a CV of 4.5% (95% CI: 3.3, 5.7) whereas 2D SE EPI achieved a CV of 7.8% (95% CI: 3.1, 12.6). The mean RC of stiffness measurement was 5.8% (95% CI: 3.7, 7.8) for all phantoms and both sequences combined, 4.9% (95% CI: 2.7, 7.0) for 2D GRE, and 7.0% (95% CI: 2.9, 11.2) for 2D SE EPI (all phantoms). Conclusion MRE had excellent in vitro precision and same-session test-retest repeatability in the multicenter setting when similar imaging protocols, hardware, and reconstruction algorithms were used. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Tang in this issue.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Fantasmas de Imagen , Diagnóstico por Imagen de Elasticidad/métodos , Diagnóstico por Imagen de Elasticidad/instrumentación , Reproducibilidad de los Resultados , Humanos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Cirrosis Hepática/diagnóstico por imagen
7.
J Matern Fetal Neonatal Med ; 37(1): 2347954, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38714523

RESUMEN

BACKGROUND: A short cervix in the second trimester is known to increase the risk of preterm birth, which can be reduced with the administration of vaginal progesterone. However, some studies have suggested that a significant number of cases still experience preterm birth despite progesterone treatment. OBJECTIVE: This study was aimed to investigate the potential value of transvaginal cervical elasticity measured by E-Cervix as a predictor for spontaneous preterm birth (sPTB) in singleton pregnancies receiving progesterone treatment for a short cervix (CL ≤ 2.5 cm) diagnosed at 18 to 24 weeks' gestation. STUDY DESIGN: This prospective study was conducted at a single center premature high-risk clinic from January 2020 to July 2022. Singleton pregnancies with a short cervix at 18 to 24 weeks' gestation were enrolled. Cervical elastography using E-Cervix was performed, and maternal and neonatal demographic characteristics, cervical length (CL), elasticity contrast index (ECI), cervical hardness ratio, mean internal os strain (IOS), and mean external os strain (EOS) were compared before and after progesterone treatment in sPTB and term birth groups. Multivariate logistic regression was used to analyze the association between elasticity parameters and spontaneous preterm birth. The screening performance of CL and optimal cervical elasticity parameters in predicting sPTB was evaluated using receiver-operating characteristic (ROC) curve analysis. RESULTS: A total of 228 singleton pregnant women were included in the study, among which 26 (11.4%) had sPTB. There were no significant differences in maternal characteristics and gestational age at enrollment between women with and without sPTB. At the start of progesterone treatment, there were no significant differences in cervical elasticity parameters between the two groups. After two weeks of progesterone treatment, women who had sPTB showed significantly higher levels of ECI, IOS, EOS (p = 0.0108, 0.0001, 0.016), and lower hardness ratio (p = 0.011) compared to those who had a full-term birth. Cervical length did not show significant differences between the two groups, regardless of whether progesterone treatment was administered before or after. Among the post-treatment cervical elasticity parameters, IOS and EOS were associated with a 3.38-fold and 2.29-fold increase in the risk of sPTB before 37 weeks (p = 0.032, 0.047, respectively). The AUROC of the combined model including CL, IOS, and EOS (0.761, 95% CI0.589-0.833) was significantly higher than the AUROC of CL alone (0.618, 95% CI 0.359-0.876). At a fixed false-positive of 13%, the addition of IOS and EOS in the CL model increased sensitivity from 34.6% to 57.6%, PPV from 25.7% to 36.5%, and NPV from 91.1% to 94.1%. CONCLUSION: When assessing the risk of sPTB in singleton pregnancies with a short cervix receiving progesterone therapy, relying solely on cervical length is insufficient. It is crucial to also evaluate cervical stiffness, particularly the strain of the internal and external os, using cervical elastography.


Asunto(s)
Cuello del Útero , Diagnóstico por Imagen de Elasticidad , Nacimiento Prematuro , Progesterona , Humanos , Femenino , Embarazo , Progesterona/administración & dosificación , Nacimiento Prematuro/prevención & control , Adulto , Estudios Prospectivos , Cuello del Útero/diagnóstico por imagen , Cuello del Útero/efectos de los fármacos , Progestinas/administración & dosificación , Progestinas/uso terapéutico , Segundo Trimestre del Embarazo , Medición de Longitud Cervical , Edad Gestacional , Administración Intravaginal , Valor Predictivo de las Pruebas
8.
Sports Med Arthrosc Rev ; 32(1): 51-57, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38695504

RESUMEN

The study aimed to describe the changes in biomechanical properties of the supraspinatus tendon, deltoid muscle, and humeral head post arthroscopic rotator cuff repair using shear wave elastography. Shear wave velocity of the tendon, deltoid, and humeral head of 48 patients was measured at predetermined sites at 1 week, 6 weeks, 12 weeks, 6 months, and 12 months post repair. One-way ANOVA with Tukey's correction and Spearman's correlation were performed. Mean±SEM healing tendon stiffness, adjacent to tendon footprint, increased from 1 week (6.2±0.2 m/s) to 6 months (7.5±0.3 m/s) and 12 months (7.8±0.3 m/s) (P<0.001). Mean±SEM deltoid muscle stiffness was higher at 12 months (4.1±0.2 m/s) compared to 1 week (3.4±0.1 m/s) and 12 weeks (3.5±0.1 m/s) (P<0.05). Humeral head stiffness did not change. Following arthroscopic rotator cuff repair, supraspinatus tendon stiffness increased in a curvilinear fashion over 6 months. From 6 months, deltoid muscle stiffness increased, corresponding to when patients were instructed to return to normal activities.


Asunto(s)
Artroscopía , Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Humanos , Fenómenos Biomecánicos , Masculino , Femenino , Manguito de los Rotadores/cirugía , Manguito de los Rotadores/fisiopatología , Lesiones del Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/fisiopatología , Persona de Mediana Edad , Diagnóstico por Imagen de Elasticidad , Músculo Deltoides/cirugía , Músculo Deltoides/fisiopatología , Anciano , Cabeza Humeral/cirugía
11.
Sci Rep ; 14(1): 10822, 2024 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-38734742

RESUMEN

With high prevalence and substantial mortality, metabolic dysfunction-associated steatotic liver disease and chronic obstructive pulmonary disease (COPD) are significant public health concerns. Utilizing a large, population-based dataset from the National Health and Nutrition Examination Survey, our study probes the relationship between COPD prevalence and hepatic steatosis and fibrosis, as measured by Vibration-Controlled Transient Elastography. We analyzed data from 693 individuals with COPD and 7229 without. Through weighted multivariate logistic regression analysis, a restricted cubic spline curve, and threshold effect analysis, we investigated the correlation between the severity of hepatic steatosis and fibrosis and the presence of COPD. Our findings revealed a positive correlation between the controlled attenuation parameter (CAP) and COPD prevalence [OR = 1.03 (95% CI 1.01, 1.05)], even after multivariate adjustment. Furthermore, we observed a U-shaped association between CAP and COPD, where the inflection point, CAP value of 264.85 dB/m, corresponded to the lowest COPD prevalence. Our study emphasizes a substantial and complex link between hepatic steatosis and COPD. These findings urge healthcare professionals to factor liver health into COPD management and prompt further exploration into the underlying mechanisms. This could pave the way for the development of improved prevention and treatment strategies.


Asunto(s)
Hígado Graso , Cirrosis Hepática , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Enfermedad Pulmonar Obstructiva Crónica/patología , Masculino , Femenino , Cirrosis Hepática/complicaciones , Cirrosis Hepática/epidemiología , Cirrosis Hepática/patología , Persona de Mediana Edad , Hígado Graso/complicaciones , Hígado Graso/epidemiología , Hígado Graso/patología , Prevalencia , Anciano , Encuestas Nutricionales , Diagnóstico por Imagen de Elasticidad , Adulto
12.
Sensors (Basel) ; 24(9)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38732804

RESUMEN

In general, it is difficult to visualize internal ocular structure and detect a lesion such as a cataract or glaucoma using the current ultrasound brightness-mode (B-mode) imaging. This is because the internal structure of the eye is rich in moisture, resulting in a lack of contrast between tissues in the B-mode image, and the penetration depth is low due to the attenuation of the ultrasound wave. In this study, the entire internal ocular structure of a bovine eye was visualized in an ex vivo environment using the compound acoustic radiation force impulse (CARFI) imaging scheme based on the phase-inverted ultrasound transducer (PIUT). In the proposed method, the aperture of the PIUT is divided into four sections, and the PIUT is driven by the out-of-phase input signal capable of generating split-focusing at the same time. Subsequently, the compound imaging technique was employed to increase signal-to-noise ratio (SNR) and to reduce displacement error. The experimental results demonstrated that the proposed technique could provide an acoustic radiation force impulse (ARFI) image of the bovine eye with a broader depth-of-field (DOF) and about 80% increased SNR compared to the conventional ARFI image obtained using the in-phase input signal. Therefore, the proposed technique can be one of the useful techniques capable of providing the image of the entire ocular structure to diagnose various eye diseases.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Ojo , Relación Señal-Ruido , Transductores , Animales , Bovinos , Ojo/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Ultrasonografía/métodos
13.
Medicine (Baltimore) ; 103(19): e38035, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38728451

RESUMEN

OBJECTIVE: The objective of this meta-analysis is to evaluate the diagnostic performance of acoustic radiation force impulse (ARFI) in acute pancreatitis (AP) patients. METHODS: PubMed, Web of Science, Embase, Wanfang, Chinese Biological Medicine databases, and Chinese Biomedical Literature Service System were searched for relevant studies to explore the potential diagnostic performance of ARFI in AP from inception to November 2023. STATA 14.0 was used to analyze the standardized mean difference (SMD) with 95% confidence interval (CI), pooled sensitivity, specificity, area under the curve, meta-regression analysis, sensitivity analysis, and publication bias. RESULTS: Nine studies, involving 533 AP patients and 585 healthy controls, were included. AP patients had significantly higher ARFI levels than healthy controls (SMD: 3.13, 95% CI: 1.88-4.39, P = .001). The area under the curve of ARFI for diagnosing AP was 0.99 (95% CI: 0.98-1.00), with 98% sensitivity and 94% specificity. Meta-regression identified the study region and study period as the sources of heterogeneity. Sensitivity analysis showed that the exclusion of any single study did not materially alter the overall combined effect. No evidence of publication bias was observed in the included studies. CONCLUSION: This meta-analysis demonstrated that ARFI exerted satisfactory diagnostic performance in AP.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Pancreatitis , Sensibilidad y Especificidad , Humanos , Pancreatitis/diagnóstico , Pancreatitis/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Enfermedad Aguda
14.
Lancet Gastroenterol Hepatol ; 9(6): 539-549, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38588691

RESUMEN

BACKGROUND: Chronic hepatitis B virus (HBV) infection is the predominant cause of hepatocellular carcinoma in west Africa, yet data on the incidence of HBV-related hepatocellular carcinoma remain scarce. We aimed to describe the uptake and early outcomes of systematic ultrasound-based hepatocellular carcinoma screening in SEN-B, which is a prospective HBV cohort in Senegal. METHODS: In this prospective cohort study, we included treatment-naive, HBsAg-positive individuals who were referred to the two infectious diseases clinics (the Department of Tropical and Infectious Diseases and Ambulatory Treatment Center) at Fann University Hospital of Dakar, Senegal, between Oct 1, 2019, and Oct 31, 2022. All participants resided within the Dakar region. Participants underwent abdominal ultrasound, transient elastography, and clinical and virological assessments at inclusion and every 6 months. Liver lesions at least 1 cm in diameter on ultrasound were assessed using four-phase CT, MRI, or liver biopsy. Adherence to hepatocellular carcinoma surveillance was measured using the proportion of time covered, calculated by dividing the cumulative months covered by abdominal ultrasound examinations by the overall follow-up time, defined as the number of months from the date of cohort entry until the last recorded visit, hepatocellular carcinoma diagnosis, or death. Optimal adherence was defined as a proportion of time covered of 100%. FINDINGS: Overall, 755 (99·6%) of 758 participants had at least one abdominal ultrasound performed. The median age of the enrolled participants was 31 years (IQR 25-39), 355 (47·0%) of 755 participants were women, and 82 (10·9%) had a family history of hepatocellular carcinoma. 15 (2·0%) of 755 individuals were HBeAg positive, 206 (27·3%) of 755 individuals had HBV DNA of more than 2000 IU/mL, and 27 (3·6%) of 755 had elastography-defined liver cirrhosis. Of ten (1·3%) participants with a focal lesion at least 1 cm at initial assessment, CT or MRI ruled out hepatocellular carcinoma in nine, whereas imaging and subsequent liver biopsy confirmed one patient with hepatocellular carcinoma. Two further patients with hepatocellular carcinoma were diagnosed at study presentation due to the presence of portal thrombosis on ultrasound. Excluding the three participants with hepatocellular carcinoma identified at baseline, 752 participants were eligible for screening every 6 months. Median follow-up time was 12 months (IQR 6-18) and the median number of ultrasounds per patient was 3 (2-4). During 809·5 person-years of follow-up, one incident hepatocellular carcinoma was reported, resulting in an incidence rate of 1·24 cases per 1000 person-years (95% CI 0·18-8·80). Overall, 702 (93·0%) of 755 participants showed optimal hepatocellular carcinoma surveillance, but this proportion decreased to 77·8% (42 of 54 participants) after 24 months. INTERPRETATION: Hepatocellular carcinoma screening is feasible in HBV research cohorts in west Africa, but its longer-term acceptability needs to be evaluated. Long-term hepatocellular carcinoma incidence data are crucial for shaping tailored screening recommendations. FUNDING: Swiss National Science Foundation, the Swiss Cancer Research Foundation, the National Cancer Institute, and Roche Diagnostics. TRANSLATION: For the French translation of the abstract see Supplementary Materials section.


Asunto(s)
Carcinoma Hepatocelular , Detección Precoz del Cáncer , Hepatitis B Crónica , Neoplasias Hepáticas , Ultrasonografía , Humanos , Carcinoma Hepatocelular/epidemiología , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/virología , Neoplasias Hepáticas/epidemiología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/virología , Senegal/epidemiología , Femenino , Masculino , Estudios Prospectivos , Adulto , Persona de Mediana Edad , Detección Precoz del Cáncer/métodos , Hepatitis B Crónica/complicaciones , Hepatitis B Crónica/epidemiología , Diagnóstico por Imagen de Elasticidad , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X
15.
Med Phys ; 51(5): 3220-3244, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38597908

RESUMEN

Physiological and pathological changes in tissues often cause changes in tissue mechanical properties, making tissue elastography an effective modality in medical imaging. Among the existing elastography methods, ultrasound elastography is of great interest due to the inherent advantages of ultrasound imaging technology, such as low cost, portability, safety, and wide availability. However, most current ultrasound elastography methods are based on the bulk shear wave; they can image deep tissues but cannot image superficial tissues. To address this challenge, ultrasonic elastography methods based on surface acoustic waves have been proposed. In this paper, we present a comprehensive review of ultrasound-based surface acoustic wave elastography techniques, including their theoretical foundations, technical implementations, and existing medical applications. The goal is to provide a concise summary of the state-of-the-art of this field, hoping to offer a reliable reference for the further development of these techniques and foster the expansion of their medical applications.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Ondas Ultrasónicas , Modelos Teóricos
16.
Sci Rep ; 14(1): 8589, 2024 04 13.
Artículo en Inglés | MEDLINE | ID: mdl-38615137

RESUMEN

Early identification of high-risk metabolic dysfunction-associated steatohepatitis (MASH) can offer patients access to novel therapeutic options and potentially decrease the risk of progression to cirrhosis. This study aimed to develop an explainable machine learning model for high-risk MASH prediction and compare its performance with well-established biomarkers. Data were derived from the National Health and Nutrition Examination Surveys (NHANES) 2017-March 2020, which included a total of 5281 adults with valid elastography measurements. We used a FAST score ≥ 0.35, calculated using liver stiffness measurement and controlled attenuation parameter values and aspartate aminotransferase levels, to identify individuals with high-risk MASH. We developed an ensemble-based machine learning XGBoost model to detect high-risk MASH and explored the model's interpretability using an explainable artificial intelligence SHAP method. The prevalence of high-risk MASH was 6.9%. Our XGBoost model achieved a high level of sensitivity (0.82), specificity (0.91), accuracy (0.90), and AUC (0.95) for identifying high-risk MASH. Our model demonstrated a superior ability to predict high-risk MASH vs. FIB-4, APRI, BARD, and MASLD fibrosis scores (AUC of 0.95 vs. 0.50, 0.50, 0.49 and 0.50, respectively). To explain the high performance of our model, we found that the top 5 predictors of high-risk MASH were ALT, GGT, platelet count, waist circumference, and age. We used an explainable ML approach to develop a clinically applicable model that outperforms commonly used clinical risk indices and could increase the identification of high-risk MASH patients in resource-limited settings.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Adulto , Humanos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Enfermedad del Hígado Graso no Alcohólico/epidemiología , Inteligencia Artificial , Encuestas Nutricionales , Aprendizaje Automático
17.
Curr Opin Obstet Gynecol ; 36(3): 181-185, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38656810

RESUMEN

PURPOSE OF REVIEW: This article reviews recent advances in ultrasound elastography in diagnosing and evaluating the normal nongravid uterus and the infertile uterus in the gynecologic patient. RECENT FINDINGS: Focusing on the most recent primary literature, studies have demonstrated new findings among a breadth of gynecologic clinical settings. Studies in the nongravid uterus have found that menopausal status, age, and menstrual phase have not been associated with changes in uterine tissue stiffness. Focusing on myometrial disease, there have been conflicting data regarding the ability to distinguish uterine fibroids from adenomyosis. One area of expanding research surrounding uterine elastography includes the infertile population, where ongoing studies attempt to provide a predictive model using shear wave elastography (SWE) in patients undergoing in-vitro fertilization. SUMMARY: Ultrasound elastography has become an increasingly studied and utilized tool in assessing physiologic and pathologic processes in the field of gynecology. Evaluating tissue stiffness through strain and SWE can serve to improve diagnosis of various uterine and cervical lesions, as well as prognosticate outcomes after fertility treatments. This growing area of research will continue to establish the role and application of ultrasound elastography into clinical practice.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Infertilidad Femenina , Útero , Humanos , Femenino , Diagnóstico por Imagen de Elasticidad/métodos , Útero/diagnóstico por imagen , Infertilidad Femenina/diagnóstico por imagen , Leiomioma/diagnóstico por imagen , Enfermedades Uterinas/diagnóstico por imagen , Neoplasias Uterinas/diagnóstico por imagen , Adenomiosis/diagnóstico por imagen
18.
BMJ Open ; 14(4): e081263, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38684277

RESUMEN

INTRODUCTION: Type 2 diabetes and non-alcoholic fatty liver disease (NAFLD) often coexist and increase risk for developing liver fibrosis and diabetes complications if no effective measures are taken. Dietary intervention is known to be able to achieve diabetes remission, while evidence regarding the long-term effect on liver fat is limited for comorbidity management of type 2 diabetes and NAFLD. This study aims to investigate the long-term effect of a Chinese Medical Nutrition Therapy (CMNT) diet accompanied by intermittent energy restriction on reducing liver fat and glycated haemoglobin (HbA1c) in patients with type 2 diabetes and NAFLD. METHODS AND ANALYSIS: This is a multicentre two-armed parallel randomised controlled trial study. 120 participants with type 2 diabetes and NAFLD will be recruited from the physical examination centres of multiple hospitals in China. Participants will be randomly allocated 1:1 to either the CMNT group or the usual care group. The CMNT group will be instructed to consume the provided specific meal replacement Chinese medicinal foods consisting of 6 cycles of 5 consecutive days followed by 10 days of regular food intake. The usual care group will be given standard dietary advice. Primary outcomes are changes in the controlled attenuation parameter value by transient elastography and HbA1c level. Secondary outcomes include differences in anthropometrics, clinical blood markers, questionnaires, gut microbiota and metabolomics. Further follow-up will be performed at 6 months, 1 year and 2 years. ETHICS AND DISSEMINATION: The study protocol was approved by the Biomedical Research Ethics Committee of Hunan Agricultural University (BRECHAU20200235).The results will be disseminated via relevant peer-reviewed publications and conference presentations. TRIAL REGISTRATION NUMBER: NCT05439226.


Asunto(s)
Diabetes Mellitus Tipo 2 , Hemoglobina Glucada , Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedad del Hígado Graso no Alcohólico/dietoterapia , Enfermedad del Hígado Graso no Alcohólico/terapia , Diabetes Mellitus Tipo 2/dietoterapia , Diabetes Mellitus Tipo 2/terapia , Hemoglobina Glucada/metabolismo , China , Ensayos Clínicos Controlados Aleatorios como Asunto , Terapia Nutricional/métodos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Hígado/metabolismo , Estudios Multicéntricos como Asunto , Diagnóstico por Imagen de Elasticidad
19.
BMC Gastroenterol ; 24(1): 133, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38609880

RESUMEN

BACKGROUND: Preventing disease progression and viral suppression are the main goals of antiviral therapy in chronic hepatitis B (CHB). Liver stiffness measurement (LSM) by transient elastography is a reliable non-invasive method to assess liver fibrosis in patients with CHB. Our aim was to explore factors that may affect changes in LSMs during long term tenofovir (TDF) monotherapy in a well characterized cohort of patients with compensated CHB. METHODS: We analyzed serial LSMs in 103 adult patients with CHB who were on TDF monotherapy and had at least three LSMs over a period of 90 months. RESULTS: Twenty-five (24%) patients had advanced fibrosis at baseline. A significant decline in mean LSM between baseline and last visit (8.7 ± 6.2 kPa vs. 6.7 ± 3.3, p = 10- 3) was observed. Twenty-four (23%) patients had progression of liver fibrosis with mean increase in liver stiffness of 2.8 kPa (range: 0.2-10.2 kPa). Multivariate analysis showed that BMI ≥ 25 (OR, 0.014; 95% CI, 0.001-0.157; p = 0.001) and advanced fibrosis (OR, 5.169; 95% CI, 1.240-21.540; p = 0.024) were independently associated with a fibrosis regression of > 30% of liver stiffness compared to baseline value. CONCLUSIONS: In CHB patients TDF monotherapy resulted in liver fibrosis regression, especially in patients with advanced fibrosis. Despite the successful antiviral effect of TDF, 1 out of 4 patients had liver fibrosis progression. Obesity and advanced fibrosis at baseline were independently associated with significant liver fibrosis regression.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hepatitis B Crónica , Adulto , Humanos , Hepatitis B Crónica/complicaciones , Hepatitis B Crónica/tratamiento farmacológico , Estudios Prospectivos , Estudios Retrospectivos , Cirrosis Hepática/diagnóstico por imagen , Tenofovir/uso terapéutico
20.
Cell Mol Biol (Noisy-le-grand) ; 70(3): 233-240, 2024 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-38650128

RESUMEN

Skin photoaging affects appearance and is associated with a variety of skin diseases, even skin cancer. Therefore, the prevention and treatment of skin photoaging is very important. However, there is a lack of effective evaluation methods, so it is an urgent problem to explore a comprehensive, non-invasive and in vivo evaluation method. Adipose-derived mesenchymal stem cells (ADSCs) are widely used to improve skin conditions as easier to obtain and positive effects. Recently, as the development of ultrasound technology, skin ultrasound has been widely used. Changes in skin layer and structure can be observed by high-frequency ultrasound (HFUS). In addition, Shear wave elastography (SWE) technology can be used to monitor the change of skin hardness. However, it is necessary to further explore the ultrasound parameters in interpreting histological changes. We simulate the progression and treatment process of human skin photoaging by using UVB-induced nude mice skin photoaging model and ADSCs injection. The analysis of the degree and therapeutic effect of skin photoaging was conducted by HFUS, SWE and to verify with histopathology. Our study aims to clarify the value of HFUS combined SWE techniques in evaluating the degree and therapeutic efficacy of skin photoaging, which provides theoretical basis for diagnosis and treatment evaluation systems.


Asunto(s)
Células Madre Mesenquimatosas , Ratones Desnudos , Envejecimiento de la Piel , Piel , Rayos Ultravioleta , Animales , Envejecimiento de la Piel/efectos de la radiación , Células Madre Mesenquimatosas/citología , Humanos , Piel/efectos de la radiación , Piel/patología , Tejido Adiposo/citología , Diagnóstico por Imagen de Elasticidad , Trasplante de Células Madre Mesenquimatosas/métodos , Ratones , Femenino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA