Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.173
Filtrar
1.
J R Soc Interface ; 21(215): 20230696, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38842440

RESUMEN

In the area of surgical applications, understanding the interaction between medical device materials and tissue is important since this interaction may cause complications. The interaction often consists of a cell monolayer touching the medical device that can be mimicked in vitro. Prominent examples of this are contact lenses, where epithelial cells interact with the contact lens, or stents and catheters, which are in contact with endothelial cells. To investigate those interactions, in previous studies, expensive microtribometers were used to avoid pressures in the contact area far beyond physiologically relevant levels. Here, we aim to present a new methodology that is cost- and time-efficient, more accessible than those used previously and allows for the application of more realistic pressures, while permitting a quantification of the damage caused to the monolayer. For this, a soft polydimethylsiloxane is employed that better mimics the mechanical properties of blood vessels than materials used in other studies. Furthermore, a technique to account for misalignments within the experiment set-up is presented. This is carried out using the raw spatial and force data recorded by the tribometer and adjusting for misalignments. The methodology is demonstrated using an endothelial cell (human umbilical vein endothelial cells) monolayer.


Asunto(s)
Células Endoteliales de la Vena Umbilical Humana , Humanos , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Fricción , Dimetilpolisiloxanos/química
2.
Integr Biol (Camb) ; 162024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38900168

RESUMEN

Oxygen levels vary in the environment. Oxygen availability has a major effect on almost all organisms, and oxygen is far more than a substrate for energy production. However, less is known about related biological processes under hypoxic conditions and about the adaptations to changing oxygen concentrations. The yeast Saccharomyces cerevisiae can adapt its metabolism for growth under different oxygen concentrations and can grow even under anaerobic conditions. Therefore, we developed a microfluidic device that can generate serial, accurately controlled oxygen concentrations for single-cell studies of multiple yeast strains. This device can construct a broad range of oxygen concentrations, [O2] through on-chip gas-mixing channels from two gases fed to the inlets. Gas diffusion through thin polydimethylsiloxane (PDMS) can lead to the equilibration of [O2] in the medium in the cell culture layer under gas cover regions within 2 min. Here, we established six different and stable [O2] varying between ~0.1 and 20.9% in the corresponding layers of the device designed for multiple parallel single-cell culture of four different yeast strains. Using this device, the dynamic responses of different yeast transcription factors and metabolism-related proteins were studied when the [O2] decreased from 20.9% to serial hypoxic concentrations. We showed that different hypoxic conditions induced varying degrees of transcription factor responses and changes in respiratory metabolism levels. This device can also be used in studies of the aging and physiology of yeast under different oxygen conditions and can provide new insights into the relationship between oxygen and organisms. Integration, innovation and insight: Most living cells are sensitive to the oxygen concentration because they depend on oxygen for survival and proper cellular functions. Here, a composite microfluidic device was designed for yeast single-cell studies at a series of accurately controlled oxygen concentrations. Using this device, we studied the dynamic responses of various transcription factors and proteins to changes in the oxygen concentration. This study is the first to examine protein dynamics and temporal behaviors under different hypoxic conditions at the single yeast cell level, which may provide insights into the processes involved in yeast and even mammalian cells. This device also provides a base model that can be extended to oxygen-related biology and can acquire more information about the complex networks of organisms.


Asunto(s)
Oxígeno , Saccharomyces cerevisiae , Análisis de la Célula Individual , Oxígeno/metabolismo , Saccharomyces cerevisiae/metabolismo , Saccharomyces cerevisiae/citología , Dimetilpolisiloxanos/química , Dispositivos Laboratorio en un Chip , Proteínas de Saccharomyces cerevisiae/metabolismo , Diseño de Equipo , Técnicas Analíticas Microfluídicas/instrumentación , Microfluídica
3.
Molecules ; 29(11)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38893504

RESUMEN

The chemical industry explosion in the 20th century has led to increased environmental pollution, affecting fauna, flora, and waterways. These substances alter water's taste, color, and smell, making it unfit for consumption or toxic. Agricultural water networks face threats from pollution before and after treatment. Some chemical contaminants, like pesticides, are embedded in natural biogeochemical cycles. In this study, we developed a simple and low-cost procedure for the fabrication of needles coated with polydimethylsiloxane (PDMS) as an efficient sorbent for the microextraction of organic pollutant traces from water. The prepared needles were used as an alternative for commercial solid-phase micro-extraction (SPME) devices in analytical chemistry. The PDMS polymeric phase was characterized by Fourier-transform infrared spectroscopy (FT-IR), thermogravimetry (TGA), and scanning electron microscopy (SEM). The PDMS-coated needles were used for extraction of thirteen pesticides by direct-immersion solid-phase microextraction (DI-SPME) from contaminated waters, followed by determination with gas chromatography-mass spectrometry (GC-MS). The developed analytical method showed limits of detection (LODs) between 0.3 and 2.5 ng mL-1 and RSDs in the range of 0.8-12.2%. The homemade needles were applied for the extraction of pesticides in surface and ground aqueous samples collected from an agricultural area. Several target pesticides were identified and quantified in the investigated water samples.


Asunto(s)
Plaguicidas , Microextracción en Fase Sólida , Contaminantes Químicos del Agua , Microextracción en Fase Sólida/métodos , Plaguicidas/análisis , Plaguicidas/aislamiento & purificación , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/aislamiento & purificación , Cromatografía de Gases y Espectrometría de Masas/métodos , Agricultura , Dimetilpolisiloxanos/química , Agua/química , Espectroscopía Infrarroja por Transformada de Fourier , Límite de Detección , Agujas
4.
Medicine (Baltimore) ; 103(24): e38414, 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38875398

RESUMEN

To investigate the efficacy of 3 root canal sealants such as AH Plus, GuttaFlow and iRoot SP combined with warm gutta-percha vertical compression technique in the treatment of dental pulp disease. This was a single-center retrospective study. 180 patients with dental pulp disease were divided into AH Plus group (n = 60), GuttaFlow group (n = 60) and iRoot SP group (n = 60) according to the different treatment methods. Patients in different groups were treated with corresponding root canal sealant combined with warm gutta-percha vertical compression technique. The quality of root canal filling, filling time, filling area ratio, the incidence of pain after operation, serum interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) and efficacy at 6 months after operation were compared among the 3 groups, respectively. The filling time in the GuttaFlow group and the iRoot SP group was significantly shorter than that in the AH Plus group (P < .001). There were significant differences in pain grade (P = .015) and pain rate (P = .016) among the 3 groups, and the pain rate in the GuttaFlow group and the iRoot SP group was significantly lower than that in the AH Plus group (P = .016). The time-point effect, intergroup effect and time-groups effect of serum TNF-α and IL-6 were significantly different (P < .001), and the levels of the 3 groups after treatment were significantly lower than those before treatment (P < .05), and the levels were significantly lower in the GuttaFlow group and the iRoot SP group (P < .05). There were significant differences in efficacy grading and effective rate among the 3 groups (P = .028), and the effective rate of iRoot SP group was significantly higher than that of AH Plus group (P < .05). The iRoot SP or GuttaFlow as root canal sealant combined with warm gutta-percha vertical compression technique in the treatment of dental pulp disease is better than AH Plus, and the former one can shorten the filling time, relieve the postoperative pain and improve the inflammatory response, but the long-term apical sealing effect of iRoot SP is better than GuttaFlow.


Asunto(s)
Gutapercha , Materiales de Obturación del Conducto Radicular , Humanos , Femenino , Masculino , Estudios Retrospectivos , Adulto , Materiales de Obturación del Conducto Radicular/uso terapéutico , Gutapercha/uso terapéutico , Enfermedades de la Pulpa Dental/terapia , Interleucina-6/sangre , Persona de Mediana Edad , Factor de Necrosis Tumoral alfa/sangre , Resultado del Tratamiento , Adulto Joven , Combinación de Medicamentos , Dimetilpolisiloxanos
5.
Sensors (Basel) ; 24(11)2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38894053

RESUMEN

The advancement of flexible electrodes triggered research on wearables and health monitoring applications. Metal-based bioelectrodes encounter low mechanical strength and skin discomfort at the electrode-skin interface. Thus, recent research has focused on the development of flexible surface electrodes with low electrochemical resistance and high conductivity. This study investigated the development of a novel, flexible, surface electrode based on a MXene/polydimethylsiloxane (PDMS)/glycerol composite. MXenes offer the benefit of featuring highly conductive transition metals with metallic properties, including a group of carbides, nitrides, and carbonitrides, while PDMS exhibits inherent biostability, flexibility, and biocompatibility. Among the various MXene-based electrode compositions prepared in this work, those composed of 15% and 20% MXene content were further evaluated for their potential in electrophysiological sensing applications. The samples underwent a range of characterization techniques, including electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), as well as mechanical and bio-signal sensing from the skin. The experimental findings indicated that the compositions demonstrated favorable bulk impedances of 280 and 111 Ω, along with conductivities of 0.462 and 1.533 mS/cm, respectively. Additionally, they displayed promising electrochemical stability, featuring charge storage densities of 0.665 mC/cm2 and 1.99 mC/cm2, respectively. By conducting mechanical tests, Young's moduli were determined to be 2.61 MPa and 2.18 MPa, respectively. The composite samples exhibited elongation of 139% and 144%, respectively. Thus, MXene-based bioelectrodes show promising potential for flexible and wearable electronics and bio-signal sensing applications.


Asunto(s)
Electrodos , Dispositivos Electrónicos Vestibles , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Humanos , Dimetilpolisiloxanos/química , Espectroscopía Dieléctrica , Conductividad Eléctrica , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Impedancia Eléctrica , Glicerol/química , Fenómenos Electrofisiológicos , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos
6.
Colloids Surf B Biointerfaces ; 239: 113963, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38759294

RESUMEN

Among various biomimetic polymer materials, polydimethylsiloxane (PDMS) stands out as an ideal matrix for surface-enhanced Raman scattering (SERS) due to its unique intrinsic Raman signal and tenacity. In order to realize the precise detection of prostate-specific antigen (PSA), we proposed a sandwich-type SERS-active immunostructure composed of PDMS@silver nanoparticles (Ag NPs)@ZIF-67 biomimetic film as the immunosubstrate and gold nanorods (Au NRs) as immunoprobes. Due to the synergistic effect of electromagnetic enhancement facilitated by biomimetic surfaces and chemical enhancement achieved by ZIF-67, this structure enabled an ultrasensitive and selective detection of PSA across a broad range from 10-3 to 10-9 mg/mL. The achieved limit of detection was as low as 3.0 × 10-10 mg/mL. Particularly, the intrinsic Raman signal of PDMS matrix at 2905 cm-1 was employed as a potential internal standard (IS) in the detection, achieving a high coefficient of determination (R2) value of 0.996. This multifunctional SERS substrate-mediated immunoassay holds vast potential for early diagnosis of prostate cancer, offering promising prospects for clinical applications.


Asunto(s)
Dimetilpolisiloxanos , Nanopartículas del Metal , Antígeno Prostático Específico , Plata , Espectrometría Raman , Plata/química , Espectrometría Raman/métodos , Inmunoensayo/métodos , Antígeno Prostático Específico/análisis , Nanopartículas del Metal/química , Dimetilpolisiloxanos/química , Humanos , Oro/química , Materiales Biomiméticos/química , Propiedades de Superficie , Límite de Detección , Nanotubos/química , Masculino , Tamaño de la Partícula , Imidazoles , Zeolitas
7.
Colloids Surf B Biointerfaces ; 239: 113977, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38776594

RESUMEN

Adoptive T cell therapy has undergone remarkable advancements in recent decades; nevertheless, the rapid and effective ex vivo expansion of tumor-reactive T cells remains a formidable challenge, limiting their clinical application. Artificial antigen-presenting substrates represent a promising avenue for enhancing the efficiency of adoptive immunotherapy and fostering T cell expansion. These substrates offer significant potential by providing flexibility and modularity in the design of tailored stimulatory environments. Polydimethylsiloxane (PDMS) silicone elastomer stands as a widely utilized biomaterial for exploring the varying sensitivity of T cell activation to substrate properties. This paper explores the optimization of PDMS surface modification and formulation to create customized stimulatory surfaces with the goal of enhancing T cell expansion. By employing soft PDMS elastomer functionalized through silanization and activating agent, coupled with site-directed protein immobilization techniques, a novel T cell stimulatory platform is introduced, facilitating T cell activation and proliferation. Notably, our findings underscore that softer modified elastomers (Young' modulus E∼300 kPa) exhibit superior efficacy in stimulating and activating mouse CD4+ T cells compared to their stiffer counterparts (E∼3 MPa). Furthermore, softened modified PDMS substrates demonstrate enhanced capabilities in T cell expansion and Th1 differentiation, offering promising insights for the advancement of T cell-based immunotherapy.


Asunto(s)
Proliferación Celular , Dimetilpolisiloxanos , Activación de Linfocitos , Propiedades de Superficie , Dimetilpolisiloxanos/química , Animales , Activación de Linfocitos/efectos de los fármacos , Ratones , Proliferación Celular/efectos de los fármacos , Linfocitos T/inmunología , Linfocitos T/efectos de los fármacos , Ratones Endogámicos C57BL
8.
J Mech Behav Biomed Mater ; 155: 106566, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38729087

RESUMEN

The objective of this study is to develop a reliable tribological model to enable a more thorough investigation of the frictional behavior of fascia tissues connected to non-specific lower back pain. Several models were designed and evaluated based on their coefficient of friction, using a low-frequency, low-load reciprocating motion. The study found that two technical elastomers, layered on PDMS to simulate the fascia and underlying muscle, are suitable substitutes for biological tissue in the model. The influence of tribopair geometry was also examined, and the results showed that greater conformity of contact leads to a lower COF, regardless of the material combination used. Finally, the friction properties of HA of various molecular weights and concentrations were tested.


Asunto(s)
Fascia , Fricción , Ensayo de Materiales , Fascia/fisiología , Dimetilpolisiloxanos/química , Fenómenos Biomecánicos , Modelos Biológicos , Elastómeros/química
9.
ACS Appl Mater Interfaces ; 16(21): 27065-27074, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38748094

RESUMEN

Wearable biomedical sensors have enabled noninvasive and continuous physiological monitoring for daily health management and early detection of chronic diseases. Among biomedical sensors, wearable pH sensors attracted significant interest, as pH influences most biological reactions. However, conformable pH sensors that have sweat absorption ability, are self-adhesive to the skin, and are gas permeable remain largely unexplored. In this study, we present a pioneering approach to this problem by developing a Janus membrane-based pH sensor with self-adhesiveness on the skin. The sensor is composed of a hydrophobic polyurethane-polydimethylsiloxane porous hundreds nanometer-thick substrate and a hydrophilic poly(vinyl alcohol)-poly(acrylic acid) porous nanofiber layer. This Janus membrane exhibits a thickness of around 10 µm, providing a conformable adhesion to the skin. The simultaneous realization of solution absorption, gas permeability, and self-adhesiveness makes it suitable for long-term continuous monitoring without compromising the comfort of the wearer. The pH sensor was tested successfully for continuous monitoring for 7.5 h, demonstrating its potential for stable analysis of skin health conditions. The Janus membrane-based pH sensor holds significant promise for comprehensive skin health monitoring and wearable biomedical applications.


Asunto(s)
Poliuretanos , Sudor , Dispositivos Electrónicos Vestibles , Concentración de Iones de Hidrógeno , Humanos , Sudor/química , Poliuretanos/química , Permeabilidad , Resinas Acrílicas/química , Membranas Artificiales , Dimetilpolisiloxanos/química , Adhesividad , Nanofibras/química , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Porosidad , Gases/química , Gases/análisis
10.
ACS Appl Mater Interfaces ; 16(21): 27728-27740, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38758746

RESUMEN

In recent decades, extensive research has been directed toward mitigating microbial contamination and preventing biofilm formation. However, many conventional antibiofilm methods rely on hazardous and toxic substances, neglecting potential risks to human health and the environment. Moreover, these approaches often rely on single-strategy mechanisms, utilizing either bactericidal or fouling-resistant agents, which have shown limited efficacy in long-term biofilm suppression. In this study, we propose an efficient and sustainable biofilm-resistant slippery hybrid slippery composite. This composite integrates nontoxic and environmentally friendly materials including chitosan, silicone oil-infused polydimethylsiloxane, and mesoporous silica nanoparticles in a synergistic manner. Leveraging the bacteria-killing properties of chitosan and the antifouling capabilities of the silicone oil layer, the hybrid composite exhibits robust antibiofilm performance against both Gram-positive and Gram-negative bacteria. Furthermore, the inclusion of mesoporous silica nanoparticles enhances the oil absorption capacity and self-replenishing properties, ensuring exceptional biofilm inhibition even under harsh conditions such as exposure to high shear flow and prolonged incubation (7 days). This approach offers promising prospects for developing effective biofilm-resistant materials with a reduced environmental impact and improved long-term performance.


Asunto(s)
Antibacterianos , Biopelículas , Quitosano , Dimetilpolisiloxanos , Nanopartículas , Dióxido de Silicio , Biopelículas/efectos de los fármacos , Quitosano/química , Quitosano/farmacología , Dióxido de Silicio/química , Dióxido de Silicio/farmacología , Nanopartículas/química , Antibacterianos/farmacología , Antibacterianos/química , Porosidad , Dimetilpolisiloxanos/química , Dimetilpolisiloxanos/farmacología , Pruebas de Sensibilidad Microbiana
11.
ACS Appl Mater Interfaces ; 16(20): 26943-26953, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38718354

RESUMEN

The continuous, noninvasive monitoring of human blood pressure (BP) through the accurate detection of pulse waves has extremely stringent requirements on the sensitivity and stability of flexible strain sensors. In this study, a new ultrasensitive flexible strain sensor based on the interlayer synergistic effect was fabricated through drop-casting and drying silver nanowires and graphene films on polydimethylsiloxane substrates and was further successfully applied for continuous monitoring of BP. This strain sensor exhibited ultrahigh sensitivity with a maximum gauge factor of 34357.2 (∼700% sensitivity enhancement over other major sensors), satisfactory response time (∼85 ms), wide strange range (12%), and excellent stability. An interlayer fracture mechanism was proposed to elucidate the working principle of the strain sensor. The real-time BP values can be obtained by analyzing the relationship between the BP and the pulse transit time. To verify our strain sensor for real-time BP monitoring, our strain sensor was compared with a conventional electrocardiogram-photoplethysmograph method and a commercial cuff-based device and showed similar measurement results to BP values from both methods, with only minor differences of 0.693, 0.073, and 0.566 mmHg in the systolic BP, diastolic BP, and mean arterial pressure, respectively. Furthermore, the reliability of the strain sensors was validated by testing 20 human subjects for more than 50 min. This ultrasensitive strain sensor provides a new pathway for continuous and noninvasive BP monitoring.


Asunto(s)
Nanocables , Plata , Humanos , Nanocables/química , Plata/química , Presión Sanguínea/fisiología , Grafito/química , Determinación de la Presión Sanguínea/instrumentación , Determinación de la Presión Sanguínea/métodos , Masculino , Dimetilpolisiloxanos/química , Nanoestructuras/química , Adulto
12.
Anal Chem ; 96(21): 8648-8656, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38716690

RESUMEN

Microfluidic analytical tools play an important role in miniaturizing targeted proteomic assays for improved detection sensitivity, throughput, and automation. Microfluidic isoelectric focusing (IEF) can resolve proteoforms in lysate from low-to-single cell numbers. However, IEF assays often use carrier ampholytes (CAs) to establish a pH gradient for protein separation, presenting limitations like pH instability in the form of cathodic drift (migration of focused proteins toward the cathode). Immobilized pH gradient (IPG) gels reduce cathodic drift by covalently immobilizing the pH buffering components to a matrix. To our knowledge, efforts to implement IPG gels at the microscale have been limited to glass microdevices. To adapt IEF using IPGs to widely used microfluidic device materials, we introduce a polydimethylsiloxane (PDMS)-based microfluidic device and compare the microscale pH gradient stability of IEF established with IPGs, CAs, and a hybrid formulation of IPG gels and CAs (mixed-bed IEF). The PDMS-based IPG microfluidic device (µIPG) resolved analytes differing by 0.1 isoelectric point within a 3.5 mm separation lane over a 20 min focusing duration. During the 20 min duration, we observed markedly different cathodic drift velocities among the three formulations: 60.1 µm/min in CA-IEF, 2.5 µm/min in IPG-IEF (∼24-fold reduction versus CA-IEF), and 1.4 µm/min in mixed-bed IEF (∼43-fold reduction versus CA-IEF). Lastly, mixed-bed IEF in a PDMS device resolved green fluorescent protein (GFP) proteoforms from GFP-expressing human breast cancer cell lysate, thus establishing stability in lysate from complex biospecimens. µIPG is a promising and stable technique for studying proteoforms from small volumes.


Asunto(s)
Dimetilpolisiloxanos , Focalización Isoeléctrica , Focalización Isoeléctrica/métodos , Humanos , Dimetilpolisiloxanos/química , Concentración de Iones de Hidrógeno , Electrodos , Técnicas Analíticas Microfluídicas/instrumentación , Fuerza Protón-Motriz , Dispositivos Laboratorio en un Chip , Geles/química
13.
Talanta ; 276: 126145, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38723473

RESUMEN

Due to the common contamination of multiple mycotoxins in food, which results in stronger toxicity, it is particularly important to simultaneously test for various mycotoxins for the protection of human health. In this study, a disposable immunosensor array with low-cost was designed and fabricated using cellulose paper, polydimethylsiloxane (PDMS), and semiconducting single-walled carbon nanotubes (s-SWCNTs), which was modified with specific antibodies for mycotoxins AFB1 and FB1 detection. The strategy for fabricating the immunosensor array with two individual channels involved a two-step protocol starting with the form of two kinds of carbon films by depositing single-wall carbon nanotubes (SWCNTs) and s-SWCNTs on the cellulose paper as the conductive wire and sensing element, followed by the assembly of chemiresistive biosensor with SWCNTs strip as the wire and s-SWCNTs as the sensing element. After immobilizing AFB1-bovine serum albumin (AFB1-BSA) and FB1-bovine serum albumin (FB1-BSA) separately on the different sensing regions, the formation of mycotoxin-BSA-antibody immunocomplexes transfers to electrochemical signal, which would change with the different concentrations of free mycotoxins. Under optimal conditions, the immunosensor array achieved a limit of detection (LOD) of 0.46 pg/mL for AFB1 and 0.34 pg/mL for FB1 within a wide dynamic range from 1 pg/mL to 20 ng/mL. Furthermore, the AFB1 and FB1 spiked in the ground corn and wheat extracts were detected with satisfactory recoveries, demonstrating the excellent practicality of this established method for simultaneous detection of mycotoxins.


Asunto(s)
Aflatoxina B1 , Técnicas Biosensibles , Celulosa , Nanotubos de Carbono , Técnicas Biosensibles/métodos , Celulosa/química , Aflatoxina B1/análisis , Aflatoxina B1/inmunología , Nanotubos de Carbono/química , Inmunoensayo/métodos , Papel , Albúmina Sérica Bovina/química , Anticuerpos Inmovilizados/inmunología , Anticuerpos Inmovilizados/química , Contaminación de Alimentos/análisis , Límite de Detección , Micotoxinas/análisis , Micotoxinas/inmunología , Dimetilpolisiloxanos
14.
Mikrochim Acta ; 191(6): 301, 2024 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709350

RESUMEN

In the era of wearable electronic devices, which are quite popular nowadays, our research is focused on flexible as well as stretchable strain sensors, which are gaining humongous popularity because of recent advances in nanocomposites and their microstructures. Sensors that are stretchable and flexible based on graphene can be a prospective 'gateway' over the considerable biomedical speciality. The scientific community still faces a great problem in developing versatile and user-friendly graphene-based wearable strain sensors that satisfy the prerequisites of susceptible, ample range of sensing, and recoverable structural deformations. In this paper, we report the fabrication, development, detailed experimental analysis and electronic interfacing of a robust but simple PDMS/graphene/PDMS (PGP) multilayer strain sensor by drop casting conductive graphene ink as the sensing material onto a PDMS substrate. Electrochemical exfoliation of graphite leads to the production of abundant, fast and economical graphene. The PGP sensor selective to strain has a broad strain range of ⁓60%, with a maximum gauge factor of 850, detection of human physiological motion and personalized health monitoring, and the versatility to detect stretching with great sensitivity, recovery and repeatability. Additionally, recoverable structural deformation is demonstrated by the PGP strain sensors, and the sensor response is quite rapid for various ranges of frequency disturbances. The structural designation of graphene's overlap and crack structure is responsible for the resistance variations that give rise to the remarkable strain detection properties of this sensor. The comprehensive detection of resistance change resulting from different human body joints and physiological movements demonstrates that the PGP strain sensor is an effective choice for advanced biomedical and therapeutic electronic device utility.


Asunto(s)
Dimetilpolisiloxanos , Grafito , Dispositivos Electrónicos Vestibles , Grafito/química , Humanos , Dimetilpolisiloxanos/química , Movimiento
15.
Arch Biochem Biophys ; 757: 110028, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38768746

RESUMEN

Biomechanical signals in the extracellular niche are considered promising for programming the lineage specification of stem cells. Recent studies have reported that biomechanics, such as the microstructure of nanomaterials, can induce adipose-derived stem cells (ASCs) to differentiate into osteoblasts, mediating gene regulation at the epigenetic level. Therefore, in this study, transcriptome expression levels of histone demethylases in ASCs were screened after treatment with different matrix stiffnesses, and histone lysine demethylase 3B (KDM3B) was found to promote osteogenic differentiation of ASCs in response to matrix stiffness, indicating a positive modulatory effect on this biological process. ASCs exhibited widespread and polygonal shapes with a distinct bundle-like expression of vinculin parallel to the axial cytoskeleton along the cell margins on the stiff matrix rather than round shapes with a smeared and shorter expression on the soft matrix. Comparatively rigid polydimethylsiloxane material directed ASCs into an osteogenic phenotype in inductive culture media via the upregulation of osteocalcin, alkaline phosphatase, and runt-related transcription factor 2. Treatment with KDM3B-siRNA decreased the expression of osteogenic differentiation markers and impaired mitochondrial dynamics and mitochondrial membrane potential. These results illustrate the critical role of KDM3B in the biomechanics-induced osteogenic commitment of ASCs and provide new avenues for the further application of stem cells as potential therapeutics for bone regeneration.


Asunto(s)
Tejido Adiposo , Diferenciación Celular , Histona Demetilasas con Dominio de Jumonji , Osteogénesis , Células Madre , Humanos , Histona Demetilasas con Dominio de Jumonji/metabolismo , Histona Demetilasas con Dominio de Jumonji/genética , Tejido Adiposo/citología , Tejido Adiposo/metabolismo , Células Madre/citología , Células Madre/metabolismo , Células Cultivadas , Matriz Extracelular/metabolismo , Dimetilpolisiloxanos/química
16.
Commun Biol ; 7(1): 617, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38778159

RESUMEN

The question of whether material stiffness enhances cell adhesion and clustering is still open to debate. Results from the literature are seemingly contradictory, with some reports illustrating that adhesion increases with surface stiffness and others suggesting that the performance of a system of cells is curbed by high values of elasticity. To address the role of elasticity as a regulator in neuronal cell adhesion and clustering, we investigated the topological characteristics of networks of neurons on polydimethylsiloxane (PDMS) surfaces - with values of elasticity (E) varying in the 0.55-2.65 MPa range. Results illustrate that, as elasticity increases, the number of neurons adhering on the surface decreases. Notably, the small-world coefficient - a topological measure of networks - also decreases. Numerical simulations and functional multi-calcium imaging experiments further indicated that the activity of neuronal cells on soft surfaces improves for decreasing E. Experimental findings are supported by a mathematical model, that explains adhesion and clustering of cells on soft materials as a function of few parameters - including the Young's modulus and roughness of the material. Overall, results indicate that - in the considered elasticity interval - increasing the compliance of a material improves adhesion, improves clustering, and enhances communication of neurons.


Asunto(s)
Adhesión Celular , Elasticidad , Neuronas , Neuronas/fisiología , Animales , Dimetilpolisiloxanos/química , Propiedades de Superficie , Módulo de Elasticidad , Células Cultivadas , Ratas
17.
Biosens Bioelectron ; 257: 116345, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38692247

RESUMEN

Nitrite (NO2-) is present in a variety of foods, but the excessive intake of NO2- can indirectly lead to carcinogenic, teratogenic, mutagenicity and other risks to the human body. Therefore, the detection of NO2- is crucial for maintaining human health. In this study, an integrated array sensor for NO2- detection is developed based on molybdenum single atom material (IMSMo-SAC) using high-resolution electrohydrodynamic (EHD) printing technology. The sensor comprises three components: a printed electrode array, multichannels designed on polydimethylsiloxane (PDMS) and an electronic signal process device with bluetooth. By utilizing Mo-SAC to facilitate electron transfer during the redox reaction, rapid and efficient detection of NO2- can be achieved. The sensor has a wide linear range of 0.1 µM-107.8 mM, a low detection limit of 33 nM and a high sensitivity of 0.637 mA-1mM-1 cm-2. Furthermore, employing this portable array sensor allows simultaneously measurements of NO2- concentrations in six different foods samples with acceptable recovery rates. This array sensor holds great potential for detecting of small molecules in various fields.


Asunto(s)
Técnicas Biosensibles , Diseño de Equipo , Análisis de los Alimentos , Límite de Detección , Molibdeno , Nitritos , Molibdeno/química , Técnicas Biosensibles/instrumentación , Nitritos/análisis , Análisis de los Alimentos/instrumentación , Humanos , Dimetilpolisiloxanos/química , Electrodos , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Contaminación de Alimentos/análisis
18.
Biomed Microdevices ; 26(2): 24, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709370

RESUMEN

We report the fabrication and characterisation of magnetic liquid beads with a solid magnetic shell and liquid core using microfluidic techniques. The liquid beads consist of a fluorinated oil core and a polymer shell with magnetite particles. The beads are generated in a flow-focusing polydimethylsiloxane (PDMS) device and cured by photo polymerisation. We investigated the response of the liquid beads to an external magnetic field by characterising their motion towards a permanent magnet. Magnetic sorting of liquid beads in a channel was achieved with 90% efficiency. The results show that the liquid beads can be controlled magnetically and have potential applications in digital microfluidics including nucleic acid amplification, drug delivery, cell culture, sensing, and tissue engineering. The present paper also discusses the magnetophoretic behaviour of the liquid bead by varying its mass and magnetite concentration in the shell. We also demonstrated the two-dimensional self-assembly of magnetic liquid beads for potential use in digital polymerase chain reaction and digital loop mediated isothermal amplification.


Asunto(s)
Dimetilpolisiloxanos , Dimetilpolisiloxanos/química , Técnicas Analíticas Microfluídicas/instrumentación , Campos Magnéticos , Microesferas
19.
Anal Chem ; 96(17): 6764-6773, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38619911

RESUMEN

Tremendous efforts have been made to develop practical and efficient microfluidic cell and particle sorting systems; however, there are technological limitations in terms of system complexity and low operability. Here, we propose a sheath flow generator that can dramatically simplify operational procedures and enhance the usability of microfluidic cell sorters. The device utilizes an embedded polydimethylsiloxane (PDMS) sponge with interconnected micropores, which is in direct contact with microchannels and seamlessly integrated into the microfluidic platform. The high-density micropores on the sponge surface facilitated fluid drainage, and the drained fluid was used as the sheath flow for downstream cell sorting processes. To fabricate the integrated device, a new process for sponge-embedded substrates was developed through the accumulation, incorporation, and dissolution of PMMA microparticles as sacrificial porogens. The effects of the microchannel geometry and flow velocity on the sheath flow generation were investigated. Furthermore, an asymmetric lattice-shaped microchannel network for cell/particle sorting was connected to the sheath flow generator in series, and the sorting performances of model particles, blood cells, and spiked tumor cells were investigated. The sheath flow generation technique developed in this study is expected to streamline conventional microfluidic cell-sorting systems as it dramatically improves versatility and operability.


Asunto(s)
Separación Celular , Técnicas Analíticas Microfluídicas , Humanos , Separación Celular/instrumentación , Separación Celular/métodos , Técnicas Analíticas Microfluídicas/instrumentación , Porosidad , Dimetilpolisiloxanos/química , Dispositivos Laboratorio en un Chip , Polimetil Metacrilato/química
20.
Nanotechnology ; 35(32)2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38648780

RESUMEN

Flexible piezoresistive pressure sensors are gaining significant attention, particularly in the realm of flexible wearable electronic skin. Here, a flexible piezoresistive pressure sensor was developed with a broad sensing range and high sensitivity. We achieved this by curing polydimethylsiloxane (PDMS) on sandpaper, creating a PDMS film as the template with a micro-protrusion structure. The core sensing layer was formed using a composite of silver nanowires (AgNWs) and waterborne polyurethane (WPU) with a similar micro-protrusion structure. The sensor stands out with its exceptional sensitivity, showing a value of 1.04 × 106kPa-1with a wide linear range from 0 to 27 kPa. It also boasts a swift response and recovery time of 160 ms, coupled with a low detection threshold of 17 Pa. Even after undergoing more than 1000 cycles, the sensor continues to deliver stable performance. The flexible piezoresistive pressure sensor based on AgNWs/WPU composite film (AWCF) can detect small pressure changes such as pulse, swallowing, etc, which indicates that the sensor has great application potential in monitoring human movement and flexible wearable electronic skin.


Asunto(s)
Dimetilpolisiloxanos , Nanocables , Poliuretanos , Presión , Plata , Dispositivos Electrónicos Vestibles , Poliuretanos/química , Nanocables/química , Plata/química , Humanos , Dimetilpolisiloxanos/química , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Movimiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA