Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
J Med Internet Res ; 26: e56504, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39058548

RESUMEN

BACKGROUND: Although wearable technology has become increasingly common, comprehensive studies examining its ownership across different sociodemographic groups are limited. OBJECTIVE: The aims of this study were to (1) measure wearable device ownership by sociodemographic characteristics in a cohort of US consumers and (2) investigate how these devices are acquired and used for health-related purposes. METHODS: Data from the Rock Health Digital Health Consumer Adoption Survey collected from 2020 to 2022 with 23,974 US participants were analyzed. The sample was US Census-matched for demographics, including age, race/ethnicity, gender, and income. The relationship between sociodemographic factors and wearable ownership was explored using descriptive analysis and multivariate logistic regression. RESULTS: Of the 23,974 respondents, 10,679 (44.5%) owned wearables. Ownership was higher among younger individuals, those with higher incomes and education levels, and respondents living in urban areas. Compared to those aged 18-24 years, respondents 65 years and older had significantly lower odds of wearable ownership (odds ratio [OR] 0.18, 95% CI 0.16-0.21). Higher annual income (≥US $200,000; OR 2.27, 95% CI 2.01-2.57) and advanced degrees (OR 2.23, 95% CI 2.01-2.48) were strong predictors of ownership. Living in rural areas reduced ownership odds (OR 0.65, 95% CI 0.60-0.72). There was a notable difference in ownership based on gender and health insurance status. Women had slightly higher ownership odds than men (OR 1.10, 95% CI 1.04-1.17). Private insurance increased ownership odds (OR 1.28, 95% CI 1.17-1.40), whereas being uninsured (OR 0.41, 95% CI 0.36-0.47) or on Medicaid (OR 0.75, 95% CI 0.68-0.82) decreased the odds of ownership. Interestingly, minority groups such as non-Hispanic Black (OR 1.14, 95% CI 1.03-1.25) and Hispanic/Latine (OR 1.20, 95% CI 1.10-1.31) respondents showed slightly higher ownership odds than other racial/ethnic groups. CONCLUSIONS: Our findings suggest that despite overall growth in wearable ownership, sociodemographic divides persist. The data indicate a need for equitable access strategies as wearables become integral to clinical and public health domains.


Asunto(s)
Propiedad , Dispositivos Electrónicos Vestibles , Humanos , Estados Unidos , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Masculino , Femenino , Adulto , Propiedad/estadística & datos numéricos , Persona de Mediana Edad , Adolescente , Adulto Joven , Anciano , Encuestas y Cuestionarios , Factores Sociodemográficos
2.
JMIR Mhealth Uhealth ; 12: e54669, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38963698

RESUMEN

BACKGROUND: Climate change increasingly impacts health, particularly of rural populations in sub-Saharan Africa due to their limited resources for adaptation. Understanding these impacts remains a challenge, as continuous monitoring of vital signs in such populations is limited. Wearable devices (wearables) present a viable approach to studying these impacts on human health in real time. OBJECTIVE: The aim of this study was to assess the feasibility and effectiveness of consumer-grade wearables in measuring the health impacts of weather exposure on physiological responses (including activity, heart rate, body shell temperature, and sleep) of rural populations in western Kenya and to identify the health impacts associated with the weather exposures. METHODS: We conducted an observational case study in western Kenya by utilizing wearables over a 3-week period to continuously monitor various health metrics such as step count, sleep patterns, heart rate, and body shell temperature. Additionally, a local weather station provided detailed data on environmental conditions such as rainfall and heat, with measurements taken every 15 minutes. RESULTS: Our cohort comprised 83 participants (42 women and 41 men), with an average age of 33 years. We observed a positive correlation between step count and maximum wet bulb globe temperature (estimate 0.06, SE 0.02; P=.008). Although there was a negative correlation between minimum nighttime temperatures and heat index with sleep duration, these were not statistically significant. No significant correlations were found in other applied models. A cautionary heat index level was recorded on 194 (95.1%) of 204 days. Heavy rainfall (>20 mm/day) occurred on 16 (7.8%) out of 204 days. Despite 10 (21%) out of 47 devices failing, data completeness was high for sleep and step count (mean 82.6%, SD 21.3% and mean 86.1%, SD 18.9%, respectively), but low for heart rate (mean 7%, SD 14%), with adult women showing significantly higher data completeness for heart rate than men (2-sided t test: P=.003; Mann-Whitney U test: P=.001). Body shell temperature data achieved 36.2% (SD 24.5%) completeness. CONCLUSIONS: Our study provides a nuanced understanding of the health impacts of weather exposures in rural Kenya. Our study's application of wearables reveals a significant correlation between physical activity levels and high temperature stress, contrasting with other studies suggesting decreased activity in hotter conditions. This discrepancy invites further investigation into the unique socioenvironmental dynamics at play, particularly in sub-Saharan African contexts. Moreover, the nonsignificant trends observed in sleep disruption due to heat expose the need for localized climate change mitigation strategies, considering the vital role of sleep in health. These findings emphasize the need for context-specific research to inform policy and practice in regions susceptible to the adverse health effects of climate change.


Asunto(s)
Calor , Población Rural , Dispositivos Electrónicos Vestibles , Humanos , Kenia/epidemiología , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Dispositivos Electrónicos Vestibles/normas , Femenino , Masculino , Adulto , Población Rural/estadística & datos numéricos , Calor/efectos adversos , Persona de Mediana Edad , Frecuencia Cardíaca/fisiología , Estudios de Cohortes , Evaluación de Resultado en la Atención de Salud/estadística & datos numéricos , Evaluación de Resultado en la Atención de Salud/métodos
3.
JMIR Mhealth Uhealth ; 12: e55094, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39018100

RESUMEN

BACKGROUND: Personal sensing, leveraging data passively and near-continuously collected with wearables from patients in their ecological environment, is a promising paradigm to monitor mood disorders (MDs), a major determinant of the worldwide disease burden. However, collecting and annotating wearable data is resource intensive. Studies of this kind can thus typically afford to recruit only a few dozen patients. This constitutes one of the major obstacles to applying modern supervised machine learning techniques to MD detection. OBJECTIVE: In this paper, we overcame this data bottleneck and advanced the detection of acute MD episodes from wearables' data on the back of recent advances in self-supervised learning (SSL). This approach leverages unlabeled data to learn representations during pretraining, subsequently exploited for a supervised task. METHODS: We collected open access data sets recording with the Empatica E4 wristband spanning different, unrelated to MD monitoring, personal sensing tasks-from emotion recognition in Super Mario players to stress detection in undergraduates-and devised a preprocessing pipeline performing on-/off-body detection, sleep/wake detection, segmentation, and (optionally) feature extraction. With 161 E4-recorded subjects, we introduced E4SelfLearning, the largest-to-date open access collection, and its preprocessing pipeline. We developed a novel E4-tailored transformer (E4mer) architecture, serving as the blueprint for both SSL and fully supervised learning; we assessed whether and under which conditions self-supervised pretraining led to an improvement over fully supervised baselines (ie, the fully supervised E4mer and pre-deep learning algorithms) in detecting acute MD episodes from recording segments taken in 64 (n=32, 50%, acute, n=32, 50%, stable) patients. RESULTS: SSL significantly outperformed fully supervised pipelines using either our novel E4mer or extreme gradient boosting (XGBoost): n=3353 (81.23%) against n=3110 (75.35%; E4mer) and n=2973 (72.02%; XGBoost) correctly classified recording segments from a total of 4128 segments. SSL performance was strongly associated with the specific surrogate task used for pretraining, as well as with unlabeled data availability. CONCLUSIONS: We showed that SSL, a paradigm where a model is pretrained on unlabeled data with no need for human annotations before deployment on the supervised target task of interest, helps overcome the annotation bottleneck; the choice of the pretraining surrogate task and the size of unlabeled data for pretraining are key determinants of SSL success. We introduced E4mer, which can be used for SSL, and shared the E4SelfLearning collection, along with its preprocessing pipeline, which can foster and expedite future research into SSL for personal sensing.


Asunto(s)
Trastornos del Humor , Aprendizaje Automático Supervisado , Dispositivos Electrónicos Vestibles , Humanos , Estudios Prospectivos , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Dispositivos Electrónicos Vestibles/normas , Masculino , Femenino , Trastornos del Humor/diagnóstico , Trastornos del Humor/psicología , Adulto , Ejercicio Físico/psicología , Ejercicio Físico/fisiología , Universidades/estadística & datos numéricos , Universidades/organización & administración
4.
Health Informatics J ; 30(2): 14604582241260607, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38900846

RESUMEN

Background: Wearables have the potential to transform healthcare by enabling early detection and monitoring of chronic diseases. This study aimed to assess wearables' acceptance, usage, and reasons for non-use. Methods: Anonymous questionnaires were used to collect data in Germany on wearable ownership, usage behaviour, acceptance of health monitoring, and willingness to share data. Results: Out of 643 respondents, 550 participants provided wearable acceptance data. The average age was 36.6 years, with 51.3% female and 39.6% residing in rural areas. Overall, 33.8% reported wearing a wearable, primarily smartwatches or fitness wristbands. Men (63.3%) and women (57.8%) expressed willingness to wear a sensor for health monitoring, and 61.5% were open to sharing data with healthcare providers. Concerns included data security, privacy, and perceived lack of need. Conclusion: The study highlights the acceptance and potential of wearables, particularly for health monitoring and data sharing with healthcare providers. Addressing data security and privacy concerns could enhance the adoption of innovative wearables, such as implants, for early detection and monitoring of chronic diseases.


Asunto(s)
Dispositivos Electrónicos Vestibles , Humanos , Alemania , Femenino , Masculino , Adulto , Estudios Transversales , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Encuestas y Cuestionarios , Persona de Mediana Edad , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/estadística & datos numéricos , Monitoreo Ambulatorio/instrumentación , Monitoreo Ambulatorio/métodos , Monitoreo Ambulatorio/estadística & datos numéricos
5.
JMIR Mhealth Uhealth ; 12: e53964, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38832585

RESUMEN

Background: Due to aging of the population, the prevalence of aortic valve stenosis will increase drastically in upcoming years. Consequently, transcatheter aortic valve implantation (TAVI) procedures will also expand worldwide. Optimal selection of patients who benefit with improved symptoms and prognoses is key, since TAVI is not without its risks. Currently, we are not able to adequately predict functional outcomes after TAVI. Quality of life measurement tools and traditional functional assessment tests do not always agree and can depend on factors unrelated to heart disease. Activity tracking using wearable devices might provide a more comprehensive assessment. Objective: This study aimed to identify objective parameters (eg, change in heart rate) associated with improvement after TAVI for severe aortic stenosis from a wearable device. Methods: In total, 100 patients undergoing routine TAVI wore a Philips Health Watch device for 1 week before and after the procedure. Watch data were analyzed offline-before TAVI for 97 patients and after TAVI for 75 patients. Results: Parameters such as the total number of steps and activity time did not change, in contrast to improvements in the 6-minute walking test (6MWT) and physical limitation domain of the transformed WHOQOL-BREF questionnaire. Conclusions: These findings, in an older TAVI population, show that watch-based parameters, such as the number of steps, do not change after TAVI, unlike traditional 6MWT and QoL assessments. Basic wearable device parameters might be less appropriate for measuring treatment effects from TAVI.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos Electrónicos Vestibles , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Estudios Prospectivos , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Dispositivos Electrónicos Vestibles/normas , Anciano de 80 o más Años , Anciano , Estenosis de la Válvula Aórtica/cirugía , Encuestas y Cuestionarios , Calidad de Vida/psicología
6.
Balkan Med J ; 41(4): 261-271, 2024 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-38829237

RESUMEN

Background: Type 1 diabetes is one of the most common chronic diseases in children. Wearable technology (insulin pumps and continuous glucose monitoring devices) that makes diabetes management relatively simple, in addition to education and follow-ups, enhances the quality of life and health of individuals with diabetes. Aims: To evaluate the impact of wearable technology on metabolic management and the quality of life in children and adolescents with type 1 diabetes. Study Design: Systematic review and meta-analysis. Methods: The Preferred Reporting System for Systematic Reviews and Meta-Analyses was used to conduct a systematic review and meta-analysis. PubMed, Web of Science, MEDLINE, Cochrane Library, EBSCO, Ulakbim and Google Scholar were searched in July 2022 and July 2023 using predetermined keywords. The methodological quality of the studies was evaluated using the Joanna Briggs Institute's Critical Appraisal Checklists for randomized controlled experimental and cross-sectional studies. The meta-analysis method was used to pool the data. Results: Eleven studies published between 2011 and 2022 were included. The total sample size of the included studies was 1,853. The meta-analysis revealed that the decrease in hemoglobin A1C (HbA1c) level in those using wearable technology was statistically significant [mean difference (MD): -0.33, Z = 2.54, p = 0.01]. However, the technology had no effect on the quality of life [standardized mean difference (SMD): 0.44, Z = 1.72, p = 0.09]. The subgroup analyses revealed that the decrease in the HbA1c level occurred in the cross-sectional studies (MD: -0.49, Z = 2.54, p = 0.01) and the 12-19 (MD = 0.59, Z = 4.40, p < 0.001) and 4-18 age groups (MD: -0.31, Z = 2.56, p = 0.01). The subgroup analyses regarding the quality of life revealed that there was no difference according to the research design. However, the quality of life was higher in the wearable technology group than in the control group in the 8-12 and 4-18 age groups (SMD: 1.32, Z = 2.31, p = 0.02 and SMD: 1.00, Z = 5.76, p < 0.001, respectively). Conclusion: Wearable technology effectively reduces the HbA1c levels in children and adolescents with type 1 diabetes in some age groups. However, it does not affect the quality of life.


Asunto(s)
Diabetes Mellitus Tipo 1 , Calidad de Vida , Dispositivos Electrónicos Vestibles , Adolescente , Niño , Humanos , Automonitorización de la Glucosa Sanguínea/métodos , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/psicología , Diabetes Mellitus Tipo 1/psicología , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/terapia , Diabetes Mellitus Tipo 1/fisiopatología , Sistemas de Infusión de Insulina/estadística & datos numéricos , Sistemas de Infusión de Insulina/psicología , Calidad de Vida/psicología , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Dispositivos Electrónicos Vestibles/normas , Dispositivos Electrónicos Vestibles/tendencias , Dispositivos Electrónicos Vestibles/psicología , Preescolar
7.
JMIR Mhealth Uhealth ; 12: e50826, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38717816

RESUMEN

BACKGROUND: Mobile health (mHealth) wearable devices are increasingly being adopted by individuals to help manage and monitor physiological signals. However, the current state of wearables does not consider the needs of racially minoritized low-socioeconomic status (SES) communities regarding usability, accessibility, and price. This is a critical issue that necessitates immediate attention and resolution. OBJECTIVE: This study's aims were 3-fold, to (1) understand how members of minoritized low-SES communities perceive current mHealth wearable devices, (2) identify the barriers and facilitators toward adoption, and (3) articulate design requirements for future wearable devices to enable equitable access for these communities. METHODS: We performed semistructured interviews with low-SES Hispanic or Latine adults (N=19) from 2 metropolitan cities in the Midwest and West Coast of the United States. Participants were asked questions about how they perceive wearables, what are the current benefits and barriers toward use, and what features they would like to see in future wearable devices. Common themes were identified and analyzed through an exploratory qualitative approach. RESULTS: Through qualitative analysis, we identified 4 main themes. Participants' perceptions of wearable devices were strongly influenced by their COVID-19 experiences. Hence, the first theme was related to the impact of COVID-19 on the community, and how this resulted in a significant increase in interest in wearables. The second theme highlights the challenges faced in obtaining adequate health resources and how this further motivated participants' interest in health wearables. The third theme focuses on a general distrust in health care infrastructure and systems and how these challenges are motivating a need for wearables. Lastly, participants emphasized the pressing need for community-driven design of wearable technologies. CONCLUSIONS: The findings from this study reveal that participants from underserved communities are showing emerging interest in using health wearables due to the COVID-19 pandemic and health care access issues. Yet, the needs of these individuals have been excluded from the design and development of current devices.


Asunto(s)
COVID-19 , Pobreza , Investigación Cualitativa , Dispositivos Electrónicos Vestibles , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , COVID-19/psicología , COVID-19/epidemiología , Hispánicos o Latinos/psicología , Hispánicos o Latinos/estadística & datos numéricos , Entrevistas como Asunto/métodos , Percepción , Pobreza/psicología , Pobreza/estadística & datos numéricos , Telemedicina/estadística & datos numéricos , Dispositivos Electrónicos Vestibles/estadística & datos numéricos
8.
JMIR Mhealth Uhealth ; 12: e50620, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38717366

RESUMEN

Background: Wearables that measure vital parameters can be potential tools for monitoring patients at home during cancer treatment. One type of wearable is a smart T-shirt with embedded sensors. Initially, smart T-shirts were designed to aid athletes in their performance analyses. Recently however, researchers have been investigating the use of smart T-shirts as supportive tools in health care. In general, the knowledge on the use of wearables for symptom monitoring during cancer treatment is limited, and consensus and awareness about compliance or adherence are lacking. objectives: The aim of this study was to evaluate adherence to and experiences with using a smart T-shirt for the home monitoring of biometric sensor data among adolescent and young adult patients undergoing cancer treatment during a 2-week period. Methods: This study was a prospective, single-cohort, mixed methods feasibility study. The inclusion criteria were patients aged 18 to 39 years and those who were receiving treatment at Copenhagen University Hospital - Rigshospitalet, Denmark. Consenting patients were asked to wear the Chronolife smart T-shirt for a period of 2 weeks. The smart T-shirt had multiple sensors and electrodes, which engendered the following six measurements: electrocardiogram (ECG) measurements, thoracic respiration, abdominal respiration, thoracic impedance, physical activity (steps), and skin temperature. The primary end point was adherence, which was defined as a wear time of >8 hours per day. The patient experience was investigated via individual, semistructured telephone interviews and a paper questionnaire. Results: A total of 10 patients were included. The number of days with wear times of >8 hours during the study period (14 d) varied from 0 to 6 (mean 2 d). Further, 3 patients had a mean wear time of >8 hours during each of their days with data registration. The number of days with any data registration ranged from 0 to 10 (mean 6.4 d). The thematic analysis of interviews pointed to the following three main themes: (1) the smart T-shirt is cool but does not fit patients with cancer, (2) the technology limits the use of the smart T-shirt, and (3) the monitoring of data increases the feeling of safety. Results from the questionnaire showed that the patients generally had confidence in the device. Conclusions: Although the primary end point was not reached, the patients' experiences with using the smart T-shirt resulted in the knowledge that patients acknowledged the need for new technologies that improve supportive cancer care. The patients were positive when asked to wear the smart T-shirt. However, technical and practical challenges in using the device resulted in low adherence. Although wearables might have potential for home monitoring, the present technology is immature for clinical use.


Asunto(s)
Estudios de Factibilidad , Neoplasias , Dispositivos Electrónicos Vestibles , Humanos , Adolescente , Masculino , Estudios Prospectivos , Femenino , Neoplasias/psicología , Neoplasias/terapia , Adulto , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Dispositivos Electrónicos Vestibles/normas , Dispositivos Electrónicos Vestibles/psicología , Estudios de Cohortes , Dinamarca , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Adulto Joven
9.
JMIR Mhealth Uhealth ; 12: e54622, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38696234

RESUMEN

BACKGROUND: Postpartum depression (PPD) poses a significant maternal health challenge. The current approach to detecting PPD relies on in-person postpartum visits, which contributes to underdiagnosis. Furthermore, recognizing PPD symptoms can be challenging. Therefore, we explored the potential of using digital biomarkers from consumer wearables for PPD recognition. OBJECTIVE: The main goal of this study was to showcase the viability of using machine learning (ML) and digital biomarkers related to heart rate, physical activity, and energy expenditure derived from consumer-grade wearables for the recognition of PPD. METHODS: Using the All of Us Research Program Registered Tier v6 data set, we performed computational phenotyping of women with and without PPD following childbirth. Intraindividual ML models were developed using digital biomarkers from Fitbit to discern between prepregnancy, pregnancy, postpartum without depression, and postpartum with depression (ie, PPD diagnosis) periods. Models were built using generalized linear models, random forest, support vector machine, and k-nearest neighbor algorithms and evaluated using the κ statistic and multiclass area under the receiver operating characteristic curve (mAUC) to determine the algorithm with the best performance. The specificity of our individualized ML approach was confirmed in a cohort of women who gave birth and did not experience PPD. Moreover, we assessed the impact of a previous history of depression on model performance. We determined the variable importance for predicting the PPD period using Shapley additive explanations and confirmed the results using a permutation approach. Finally, we compared our individualized ML methodology against a traditional cohort-based ML model for PPD recognition and compared model performance using sensitivity, specificity, precision, recall, and F1-score. RESULTS: Patient cohorts of women with valid Fitbit data who gave birth included <20 with PPD and 39 without PPD. Our results demonstrated that intraindividual models using digital biomarkers discerned among prepregnancy, pregnancy, postpartum without depression, and postpartum with depression (ie, PPD diagnosis) periods, with random forest (mAUC=0.85; κ=0.80) models outperforming generalized linear models (mAUC=0.82; κ=0.74), support vector machine (mAUC=0.75; κ=0.72), and k-nearest neighbor (mAUC=0.74; κ=0.62). Model performance decreased in women without PPD, illustrating the method's specificity. Previous depression history did not impact the efficacy of the model for PPD recognition. Moreover, we found that the most predictive biomarker of PPD was calories burned during the basal metabolic rate. Finally, individualized models surpassed the performance of a conventional cohort-based model for PPD detection. CONCLUSIONS: This research establishes consumer wearables as a promising tool for PPD identification and highlights personalized ML approaches, which could transform early disease detection strategies.


Asunto(s)
Biomarcadores , Depresión Posparto , Dispositivos Electrónicos Vestibles , Humanos , Depresión Posparto/diagnóstico , Depresión Posparto/psicología , Femenino , Adulto , Biomarcadores/análisis , Estudios Transversales , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Dispositivos Electrónicos Vestibles/normas , Aprendizaje Automático/normas , Embarazo , Estados Unidos , Conjuntos de Datos como Asunto , Curva ROC
10.
Commun Biol ; 5(1): 58, 2022 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-35039601

RESUMEN

Parkinson's disease (PD) is one of the first diseases where digital biomarkers demonstrated excellent performance in differentiating disease from healthy individuals. However, no study has systematically compared and leveraged multiple types of digital biomarkers to predict PD. Particularly, machine learning works on the fine-motor skills of PD are limited. Here, we developed deep learning methods that achieved an AUC (Area Under the receiver operator characteristic Curve) of 0.933 in identifying PD patients on 6418 individuals using 75048 tapping accelerometer and position records. Performance of tapping is superior to gait/rest and voice-based models obtained from the same benchmark population. Assembling the three models achieved a higher AUC of 0.944. Notably, the models not only correlated strongly to, but also performed better than patient self-reported symptom scores in diagnosing PD. This study demonstrates the complementary predictive power of tapping, gait/rest and voice data and establishes integrative deep learning-based models for identifying PD.


Asunto(s)
Biomarcadores/análisis , Enfermedad de Parkinson/diagnóstico , Autoinforme , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
11.
Sci Rep ; 11(1): 21501, 2021 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-34728746

RESUMEN

Smartphones and wearable devices can be used to remotely monitor health behaviors, but little is known about how individual characteristics influence sustained use of these devices. Leveraging data on baseline activity levels and demographic, behavioral, and psychosocial traits, we used latent class analysis to identify behavioral phenotypes among participants randomized to track physical activity using a smartphone or wearable device for 6 months following hospital discharge. Four phenotypes were identified: (1) more agreeable and conscientious; (2) more active, social, and motivated; (3) more risk-taking and less supported; and (4) less active, social, and risk-taking. We found that duration and consistency of device use differed by phenotype for wearables, but not smartphones. Additionally, "at-risk" phenotypes 3 and 4 were more likely to discontinue use of a wearable device than a smartphone, while activity monitoring in phenotypes 1 and 2 did not differ by device type. These findings could help to better target remote-monitoring interventions for hospitalized patients.


Asunto(s)
Ejercicio Físico , Conductas Relacionadas con la Salud , Monitoreo Fisiológico/métodos , Motivación , Teléfono Inteligente/estadística & datos numéricos , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad
12.
Comput Math Methods Med ; 2021: 6534942, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34497664

RESUMEN

The diagnosis of electrocardiogram (ECG) is extremely onerous and inefficient, so it is necessary to use a computer-aided diagnosis of ECG signals. However, it is still a challenging problem to design high-accuracy ECG algorithms suitable for the medical field. In this paper, a classification method is proposed to classify ECG signals. Firstly, wavelet transform is used to denoise the original data, and data enhancement technology is used to overcome the problem of an unbalanced dataset. Secondly, an integrated convolutional neural network (CNN) and gated recurrent unit (GRU) classifier is proposed. The proposed network consists of a convolution layer, followed by 6 local feature extraction modules (LFEM), a GRU, and a Dense layer and a Softmax layer. Finally, the processed data were input into the CNN-GRU network into five categories: nonectopic beats, supraventricular ectopic beats, ventricular ectopic beats, fusion beats, and unknown beats. The MIT-BIH arrhythmia database was used to evaluate the approach, and the average sensitivity, accuracy, and F1-score of the network for 5 types of ECG were 99.33%, 99.61%, and 99.42%. The evaluation criteria of the proposed method are superior to other state-of-the-art methods, and this model can be applied to wearable devices to achieve high-precision monitoring of ECG.


Asunto(s)
Arritmias Cardíacas/clasificación , Arritmias Cardíacas/diagnóstico , Diagnóstico por Computador/estadística & datos numéricos , Electrocardiografía/clasificación , Electrocardiografía/estadística & datos numéricos , Redes Neurales de la Computación , Algoritmos , Biología Computacional , Bases de Datos Factuales/estadística & datos numéricos , Aprendizaje Profundo , Frecuencia Cardíaca , Humanos , Monitoreo Ambulatorio/estadística & datos numéricos , Procesamiento de Señales Asistido por Computador , Análisis de Ondículas , Dispositivos Electrónicos Vestibles/estadística & datos numéricos
13.
Nat Commun ; 12(1): 4731, 2021 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-34354053

RESUMEN

Electrodermal devices that capture the physiological response of skin are crucial for monitoring vital signals, but they often require convoluted layered designs with either electronic or ionic active materials relying on complicated synthesis procedures, encapsulation, and packaging techniques. Here, we report that the ionic transport in living systems can provide a simple mode of iontronic sensing and bypass the need of artificial ionic materials. A simple skin-electrode mechanosensing structure (SEMS) is constructed, exhibiting high pressure-resolution and spatial-resolution, being capable of feeling touch and detecting weak physiological signals such as fingertip pulse under different skin humidity. Our mechanical analysis reveals the critical role of instability in high-aspect-ratio microstructures on sensing. We further demonstrate pressure mapping with millimeter-spatial-resolution using a fully textile SEMS-based glove. The simplicity and reliability of SEMS hold great promise of diverse healthcare applications, such as pulse detection and recovering the sensory capability in patients with tactile dysfunction.


Asunto(s)
Fenómenos Fisiológicos de la Piel , Tacto/fisiología , Dispositivos Electrónicos Vestibles , Fenómenos Biomecánicos , Simulación por Computador , Electrodos , Diseño de Equipo , Dedos/fisiología , Análisis de Elementos Finitos , Humanos , Mecanorreceptores/fisiología , Presión , Procesamiento de Señales Asistido por Computador , Relación Señal-Ruido , Textiles , Dispositivos Electrónicos Vestibles/estadística & datos numéricos
14.
Int J Behav Nutr Phys Act ; 18(1): 97, 2021 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-34271922

RESUMEN

BACKGROUND: Wearable technologies play an important role in measuring physical activity (PA) and promoting health. Standardized validation indices (i.e., accuracy, bias, and precision) compare performance of step counting wearable technologies in young people. PURPOSE: To produce a catalog of validity indices for step counting wearable technologies assessed during different treadmill speeds (slow [0.8-3.2 km/h], normal [4.0-6.4 km/h], fast [7.2-8.0 km/h]), wear locations (waist, wrist/arm, thigh, and ankle), and age groups (children, 6-12 years; adolescents, 13-17 years; young adults, 18-20 years). METHODS: One hundred seventeen individuals (13.1 ± 4.2 years, 50.4% female) participated in this cross-sectional study and completed 5-min treadmill bouts (0.8 km/h to 8.0 km/h) while wearing eight devices (Waist: Actical, ActiGraph GT3X+, NL-1000, SW-200; Wrist: ActiGraph GT3X+; Arm: SenseWear; Thigh: activPAL; Ankle: StepWatch). Directly observed steps served as the criterion measure. Accuracy (mean absolute percentage error, MAPE), bias (mean percentage error, MPE), and precision (correlation coefficient, r; standard deviation, SD; coefficient of variation, CoV) were computed. RESULTS: Five of the eight tested wearable technologies (i.e., Actical, waist-worn ActiGraph GT3X+, activPAL, StepWatch, and SW-200) performed at < 5% MAPE over the range of normal speeds. More generally, waist (MAPE = 4%), thigh (4%) and ankle (5%) locations displayed higher accuracy than the wrist location (23%) at normal speeds. On average, all wearable technologies displayed the lowest accuracy across slow speeds (MAPE = 50.1 ± 35.5%), and the highest accuracy across normal speeds (MAPE = 15.9 ± 21.7%). Speed and wear location had a significant effect on accuracy and bias (P < 0.001), but not on precision (P > 0.05). Age did not have any effect (P > 0.05). CONCLUSIONS: Standardized validation indices focused on accuracy, bias, and precision were cataloged by speed, wear location, and age group to serve as important reference points when selecting and/or evaluating device performance in young people moving forward. Reduced performance can be expected at very slow walking speeds (0.8 to 3.2 km/h) for all devices. Ankle-worn and thigh-worn devices demonstrated the highest accuracy. Speed and wear location had a significant effect on accuracy and bias, but not precision. TRIAL REGISTRATION: Clinicaltrials.gov NCT01989104 . Registered November 14, 2013.


Asunto(s)
Actigrafía/normas , Catálogos como Asunto , Caminata , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Dispositivos Electrónicos Vestibles/normas , Adolescente , Adulto , Niño , Estudios Transversales , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Adulto Joven
15.
Harm Reduct J ; 18(1): 75, 2021 07 23.
Artículo en Inglés | MEDLINE | ID: mdl-34301246

RESUMEN

BACKGROUND: The incidence of opioid-related overdose deaths has been rising for 30 years and has been further exacerbated amidst the COVID-19 pandemic. Naloxone can reverse opioid overdose, lower death rates, and enable a transition to medication for opioid use disorder. Though current formulations for community use of naloxone have been shown to be safe and effective public health interventions, they rely on bystander presence. We sought to understand the preferences and minimum necessary conditions for wearing a device capable of sensing and reversing opioid overdose among people who regularly use opioids. METHODS: We conducted a combined cross-sectional survey and semi-structured interview at a respite center, shelter, and syringe exchange drop-in program in Philadelphia, Pennsylvania, USA, during the COVID-19 pandemic in August and September 2020. The primary aim was to explore the proportion of participants who would use a wearable device to detect and reverse overdose. Preferences regarding designs and functionalities were collected via a questionnaire with items having Likert-based response options and a semi-structured interview intended to elicit feedback on prototype designs. Independent variables included demographics, opioid use habits, and previous experience with overdose. RESULTS: A total of 97 adults with an opioid use history of at least 3 months were interviewed. A majority of survey participants (76%) reported a willingness to use a device capable of detecting an overdose and automatically administering a reversal agent upon initial survey. When reflecting on the prototype, most respondents (75.5%) reported that they would wear the device always or most of the time. Respondents indicated discreetness and comfort as important factors that increased their chance of uptake. Respondents suggested that people experiencing homelessness and those with low tolerance for opioids would be in greatest need of the device. CONCLUSIONS: The majority of people sampled with a history of opioid use in an urban setting were interested in having access to a device capable of detecting and reversing an opioid overdose. Participants emphasized privacy and comfort as the most important factors influencing their willingness to use such a device. TRIAL REGISTRATION: NCT04530591.


Asunto(s)
Naloxona/administración & dosificación , Antagonistas de Narcóticos/administración & dosificación , Sobredosis de Opiáceos/diagnóstico , Sobredosis de Opiáceos/tratamiento farmacológico , Aceptación de la Atención de Salud/estadística & datos numéricos , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Adolescente , Adulto , Niño , Estudios Transversales , Femenino , Humanos , Entrevistas como Asunto , Masculino , Naloxona/uso terapéutico , Antagonistas de Narcóticos/uso terapéutico , Sobredosis de Opiáceos/psicología , Aceptación de la Atención de Salud/psicología , Philadelphia , Dispositivos Electrónicos Vestibles/psicología , Adulto Joven
16.
J Mol Recognit ; 34(11): e2927, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34288170

RESUMEN

Monitoring of herbicides and pesticides in water, food, and the environment is essential for human health, and this requires low-cost, portable devices for widespread deployment of this technology. For the first time, a wearable glove-based electrochemical sensor based on conductive Ag nano-ink was developed for the on-site monitoring of trifluralin residue on the surface of various substrates. Three electrode system with optimal thicknesses was designed directly on the finger surface of a rubber glove. Then, fabricated electrochemical sensor used for the direct detection of trifluralin in the range of 0.01 µM to 1 mM on the surface of tomato and mulberry leaves using square wave voltammetry (SWV) and difference pulse voltammetry technique. The obtained LLOQ was 0.01 µM, which indicates the suitable sensitivity of this sensor. On the other hand, this sensor is portable, easy to use, and has a high environmental capability that can be effective in detecting other chemical threats in the soil and water environment.


Asunto(s)
Técnicas Biosensibles/instrumentación , Electrodos , Contaminación Ambiental/análisis , Herbicidas/análisis , Monitoreo Fisiológico/instrumentación , Trifluralina/análisis , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Técnicas Biosensibles/métodos , Técnicas Electroquímicas , Dedos/fisiología , Humanos , Solanum lycopersicum/metabolismo , Monitoreo Fisiológico/métodos , Morus/metabolismo , Hojas de la Planta/metabolismo , Tacto
17.
Comput Math Methods Med ; 2021: 6665357, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34194537

RESUMEN

In recent years, deep learning (DNN) based methods have made leapfrogging level breakthroughs in detecting cardiac arrhythmias as the cost effectiveness of arithmetic power, and data size has broken through the tipping point. However, the inability of these methods to provide a basis for modeling decisions limits clinicians' confidence on such methods. In this paper, a Gate Recurrent Unit (GRU) and decision tree fusion model, referred to as (T-GRU), was designed to explore the problem of arrhythmia recognition and to improve the credibility of deep learning methods. The fusion model multipathway processing time-frequency domain featured the introduction of decision tree probability analysis of frequency domain features, the regularization of GRU model parameters and weight control to improve the decision tree model output weights. The MIT-BIH arrhythmia database was used for validation. Results showed that the low-frequency band features dominated the model prediction. The fusion model had an accuracy of 98.31%, sensitivity of 96.85%, specificity of 98.81%, and precision of 96.73%, indicating its high reliability and clinical significance.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Diagnóstico por Computador/métodos , Algoritmos , Biología Computacional , Bases de Datos Factuales , Árboles de Decisión , Aprendizaje Profundo , Diagnóstico por Computador/estadística & datos numéricos , Electrocardiografía/estadística & datos numéricos , Humanos , Modelos Cardiovasculares , Redes Neurales de la Computación , Análisis de Ondículas , Dispositivos Electrónicos Vestibles/estadística & datos numéricos
18.
Comput Math Methods Med ; 2021: 5574376, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33986824

RESUMEN

In recent times, there has been a significant growth in networks known as the wireless body area networks (WBANs). A WBAN connects distributed nodes throughout the human body, which can be placed on the skin, under the skin, or on clothing and can use the human body's electromagnetic waves. An approach to reduce the size of different telecommunication equipment is constantly being sought; this allows these devices to be closer to the body or even glued and embedded within the skin without making the user feel uncomfortable or posing as a danger for the user. These networks promise new medical applications; however, these are always based on the freedom of movement and the comfort they offer. Among the advantages of these networks is that they can significantly increase user's quality of life. For example, a person can carry a WBAN with built-in sensors that calculate the user's heart rate at any given time and send these data over the internet to user's doctor. This study provides a systematic review of WBAN, describing the applications and trends that have been developed with this type of network and, in addition, the protocols and standards that must be considered.


Asunto(s)
Equipos y Suministros , Monitoreo Ambulatorio/instrumentación , Dispositivos Electrónicos Vestibles , Biología Computacional , Redes de Comunicación de Computadores , Equipos y Suministros/estadística & datos numéricos , Humanos , Redes de Área Local , Monitoreo Ambulatorio/estadística & datos numéricos , Calidad de Vida , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Tecnología Inalámbrica/estadística & datos numéricos
19.
Comput Math Methods Med ; 2021: 5597559, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33868451

RESUMEN

BACKGROUND: Pulse rate variability monitoring and atrial fibrillation detection algorithms have been widely used in wearable devices, but the accuracies of these algorithms are restricted by the signal quality of pulse wave. Time synchronous averaging is a powerful noise reduction method for periodic and approximately periodic signals. It is usually used to extract single-period pulse waveforms, but has nothing to do with pulse rate variability monitoring and atrial fibrillation detection traditionally. If this method is improved properly, it may provide a new way to measure pulse rate variability and to detect atrial fibrillation, which may have some potential advantages under the condition of poor signal quality. OBJECTIVE: The objective of this paper was to develop a new measure of pulse rate variability by improving existing time synchronous averaging and to detect atrial fibrillation by the new measure of pulse rate variability. METHODS: During time synchronous averaging, two adjacent periods were regarded as the basic unit to calculate the average signal, and the difference between waveforms of the two adjacent periods was the new measure of pulse rate variability. 3 types of distance measures (Euclidean distance, Manhattan distance, and cosine distance) were tested to measure this difference on a simulated training set with a capacity of 1000. The distance measure, which can accurately distinguish regular pulse rate and irregular pulse rate, was used to detect atrial fibrillation on the testing set with a capacity of 62 (11 with atrial fibrillation, 8 with premature contraction, and 43 with sinus rhythm). The receiver operating characteristic curve was used to evaluate the performance of the indexes. RESULTS: The Euclidean distance between waveforms of the two adjacent periods performs best on the training set. On the testing set, the Euclidean distance in atrial fibrillation group is significantly higher than that of the other two groups. The area under receiver operating characteristic curve to identify atrial fibrillation was 0.998. With the threshold of 2.1, the accuracy, sensitivity, and specificity were 98.39%, 100%, and 98.04%, respectively. This new index can detect atrial fibrillation from pulse wave signal. CONCLUSION: This algorithm not only provides a new perspective to detect AF but also accomplishes the monitoring of PRV and the extraction of single-period pulse wave through the same technical route, which may promote the popularization and application of pulse wave.


Asunto(s)
Algoritmos , Fibrilación Atrial/diagnóstico , Frecuencia Cardíaca , Análisis de la Onda del Pulso/estadística & datos numéricos , Análisis de Varianza , Fibrilación Atrial/fisiopatología , Biología Computacional , Diagnóstico por Computador/estadística & datos numéricos , Humanos , Aprendizaje Automático , Curva ROC , Arteria Radial/fisiología , Dispositivos Electrónicos Vestibles/estadística & datos numéricos
20.
Workplace Health Saf ; 69(9): 419-422, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33880979

RESUMEN

How do you assess the mental wellness of your work-from-home employees? This case study reports on how an occupational health nurse used work-from-home employee's own phone and Fitbit™ smartwatch to obtain heart rate data to screen for high periods of stress. Telemedicine and telemetry allowed the occupational health nurses to screen an employee when the nurse could not assess the employee face-to-face. When the occupational health nurses identified an at-risk employee, the occupational health nurses referred the employee to the Employee Assistance Program (EAP) for counseling. Leveraging heart rate data on a smartwatch is a free intervention that is scalable and has a demonstrated outcome measure with a positive return on investment.


Asunto(s)
Estrés Laboral/diagnóstico , Distrés Psicológico , Tecnología de Sensores Remotos/instrumentación , Estudios de Seguimiento , Determinación de la Frecuencia Cardíaca/instrumentación , Humanos , Estrés Laboral/psicología , Tecnología de Sensores Remotos/métodos , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Lugar de Trabajo/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...