RESUMEN
OBJECTIVE: The purpose of this study was to assess the efficacy of echocardiography-guided ascending aortic central cannulation using the Seldinger technique during surgery for type A acute aortic dissection complicated by stroke due to cerebral malperfusion. METHODS: Between April 2007 and December 2017, 208 patients with type A acute aortic dissection underwent echocardiography-guided ascending aortic central cannulation using the Seldinger technique. We analyzed 16 of these patients (7.7%; median age, 63 years; 8 men) with stroke due to cerebral malperfusion, including 10 in a comatose state (Glasgow Coma Scale ≤8) and 6 with hemiplegia (manual muscle test ≤1) on hospital arrival. The Modified Rankin Scale was used to evaluate activities of daily living. RESULTS: The median time from onset of symptoms to establishment of cardiopulmonary bypass was 327 (176-561) minutes. The median time from the start of surgery to establishment of cardiopulmonary bypass was 34 (30-44) minutes. The mortality rate was 6.3% (1/16). In patients with preoperative coma, the Glasgow Coma Scale improved significantly after surgery from 4.5 to 15 at 30 days (P < .001). In patients with preoperative hemiplegia, 4 showed improved motor function on the manual muscle test score at 90 days. In all patients, Modified Rankin Scale scores improved significantly from 5.0 preoperatively to 1.0 after follow-up (P < .001). CONCLUSIONS: Echocardiography-guided ascending aortic central cannulation using the Seldinger technique has potential as a rapid and reliable perfusion route during surgery for type A acute aortic dissection complicated by stroke due to cerebral malperfusion.
Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Cateterismo Periférico/métodos , Circulación Cerebrovascular , Ecocardiografía Doppler en Color , Accidente Cerebrovascular/etiología , Ultrasonografía Intervencional/métodos , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Aneurisma de la Aorta/complicaciones , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Ecocardiografía Doppler en Color/efectos adversos , Ecocardiografía Doppler en Color/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias/mortalidad , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional/efectos adversos , Ultrasonografía Intervencional/mortalidadRESUMEN
To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ2=5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=-2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.
Asunto(s)
Medios de Contraste/administración & dosificación , Ecocardiografía Doppler en Color/métodos , Foramen Oval Permeable/diagnóstico por imagen , Foramen Oval/diagnóstico por imagen , Bicarbonato de Sodio/administración & dosificación , Vitamina B 6/administración & dosificación , Adolescente , Adulto , Anciano , Infarto Cerebral/etiología , Medios de Contraste/efectos adversos , Circulación Coronaria , Ecocardiografía Doppler en Color/efectos adversos , Ecocardiografía Transesofágica , Estudios de Factibilidad , Femenino , Foramen Oval/anomalías , Foramen Oval/fisiopatología , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/fisiopatología , Hemodinámica , Humanos , Masculino , Microburbujas , Persona de Mediana Edad , Trastornos Migrañosos/etiología , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Bicarbonato de Sodio/efectos adversos , Maniobra de Valsalva , Vitamina B 6/efectos adversos , Adulto JovenRESUMEN
The aim of our study was to evaluate the thermal index (TI) and mechanical index (MI), during the assessment of the fetal heart at the time of first-trimester scan, with different ultrasound machines. This was part of an observational study conducted in patients undergoing routine first-trimester screening. Cases were examined with Voluson E8 or 730Pro scanners using 2-8 MHz transabdominal probes. TI and MI were retrieved from the saved displays while in gray mode, color flow mapping and pulsed-wave (PW) Doppler examinations of the fetal heart and also from the ductus venosus (DV) assessment. We evaluated 552 fetal cardiac examinations, 303 (55%) performed with Voluson E8 and 249 (45%) with Voluson 730Pro ultrasound machines. The gray-scale exam of the heart and the PW Doppler DV assessment had TI values significantly lower for the Voluson E8 group (median, 0.04 vs. 0.2 and 0.1 vs. 0.2, respectively). The MI values from gray-scale and color flow mapping of the heart were significantly lower (median, 0.6 vs, 1.2 and 0.7 vs. 1) and for PW Doppler exam of the tricuspid flow were significantly higher (median 0.4 vs. 0.2) in the Voluson E8 group. The TI values from Doppler examinations of the heart, either color flow or PW imaging and MI values from DV assessment were not significantly different between the two groups. A different (newer) generation of ultrasound equipment provides lower or at least the same safety indices for most of the first-trimester heart examinations.
Asunto(s)
Ecocardiografía Doppler en Color/efectos adversos , Corazón Fetal/diagnóstico por imagen , Ultrasonografía Prenatal/efectos adversos , Adulto , Femenino , Humanos , Embarazo , Primer Trimestre del Embarazo , Estudios ProspectivosRESUMEN
BACKGROUND: Transoesophageal echocardiography (TOE) is feasible in neonates using a miniaturized probe, but is not widely used because of low imaging quality. AIMS: To assess handling and imaging quality of a new release of a micro-TOE probe in children. METHODS: Thirty-eight consecutive children, enrolled during February and May 2013, underwent TOE with the Philips S8-3t probe. Insertion, handling and image quality were assessed. RESULTS: The 38 children (aged 7days to 12years; weight 3.1-27kg) underwent 75 TOE (30 [40.0%] before cardiac surgery, 31 [41.3%] after cardiac surgery, 4 [5.3%] during a percutaneous procedure, 10 [13.3%] in the intensive care unit). Insertion of the micro-TOE probe was 'very easy' in 37/38 patients (97.4%). Handling was better in the lightest children (P=0.001). Image quality was mainly 'good' or 'very good', with no significant changes between preoperative and postoperative examinations or over time. Total scores (insertion, handling, image quality) were significantly better in the lightest children (P=0.02). Preoperative TOE did not provide additional information over transthoracic echocardiography. Postoperative TOE was useful to assess surgical results, but no residual lesions required extracorporeal circulation return. Micro-TOE was useful during the postoperative care of neonatal surgery with open breastbone to assess the surgical result and ventricular function. It was also useful to guide extracorporeal membrane oxygenation (ECMO) indication and withdrawal; and was a useful guide for percutaneous procedures. CONCLUSION: Micro-multiplane TOE is safe and efficient for use in neonates and children. This minimally invasive tool increases the impact of TOE in paediatric cardiology.
Asunto(s)
Ecocardiografía Doppler en Color/instrumentación , Ecocardiografía Transesofágica/instrumentación , Cardiopatías/diagnóstico por imagen , Factores de Edad , Peso Corporal , Niño , Preescolar , Ecocardiografía Doppler en Color/efectos adversos , Ecocardiografía Transesofágica/efectos adversos , Diseño de Equipo , Cardiopatías/terapia , Humanos , Interpretación de Imagen Asistida por Computador , Lactante , Recién Nacido , Miniaturización , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de RiesgoRESUMEN
Prevalence of dynamic left ventricular outflow tract obstruction (DLVO) during dobutamine stress-echo (DSE) seems disproportionally high among diabetic patients. We retrospectively identified 212 diabetic (D+) and 212 non diabetic (D-) subjects, who underwent DSE for suspected coronary artery disease (CAD); we evaluated DSE-induced DLVO prevalence and correlates. During DSE, 105 patients in D+ (50%) and 83 in D- group (39%, P = 0.032) developed a DLVO, with similar maximum gradient (94 ± 49 mmHg in D+ vs. 86 ± 49 mmHg in D-, P = NS). D+ and D- patients with DLVO showed reduced LV end-diastolic and end-systolic dimension. Compared with diabetic subjects without DLVO, diabetic patients with DLVO had higher left ventricular (LV) ejection fraction (EF), lower LV mass index; diastolic function was normal in a higher proportion of cases. Non diabetic patients with moderate or severe DLVO had higher LV EF compared with patients without DLVO. At multivariate analysis, in D+ patients, the only independent predictor was a smaller LV end-diastolic diameter (HR 0.779, CI 0.655-0.926, P = 0.005); in D- patients lower age (HR 0.878, CI 0.806-0.957, P = 0.003), higher LV EF (HR 1.087, CI 1.003-1.177, P = 0.042) and lower peak WMSI (HR 0.017, CI 0.001-0.325, P = 0.007) were associated to presence of DLVO. In D+ patients, during a median follow-up of 924 ± 134 days, we observed 11 new cardiac events, only 1 in patients with DLVO (P = 0.0041). DSE-provoked DLVO had a very high prevalence in patients evaluated for suspected CAD, especially among diabetic patients; echocardiographic predictors were a reduced LV dimension in D+ and a preserved systolic function, both at rest and at peak stress, in D- patients.
Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Diabetes Mellitus/diagnóstico por imagen , Ecocardiografía Doppler en Color/efectos adversos , Ecocardiografía de Estrés/efectos adversos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Anciano , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/fisiopatología , Diabetes Mellitus/epidemiología , Diabetes Mellitus/fisiopatología , Femenino , Humanos , Italia/epidemiología , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Prevalencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Función Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo/epidemiología , Obstrucción del Flujo Ventricular Externo/fisiopatologíaRESUMEN
Left atrial spontaneous echo contrast (SEC) is a dynamic smoke-like signal caused by an increased ultrasonic backscatter from aggregation of the cellular components of blood in the conditions of blood stases or low-velocity blood flow. SEC can be detected by transesophageal echocardiography (TEE). SEC has been proposed as an important cadioembolic source in patients with nonrheumatic arial fibrillation. Previous clinical investigations have shown that the presence of SEC is associated with a greater incidence of left atrial thrombi. Usually, the blood flow velocity is slower than lower limit of Doppler method in SEC. In order to diagnose SEC quantitatively, blood flow visualization in left atrium was performed using gradient based optical flow estimation. A movie of left atrium (LA) with SEC in a patient with atrial fibrillation was recorded by TEE with the frequency range of 4-7.5 MHz. Serial still frames were made from the movie. The 2-D flow vector map was calculated from consecutive frame images using gradient based optical flow estimation. In the result of 2-D blood flow vector map, the low and swirling flow in LA were successfully visualized.
Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Trombosis Coronaria/diagnóstico , Ecocardiografía Doppler en Color/métodos , Ecocardiografía Transesofágica/métodos , Atrios Cardíacos/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/fisiopatología , Velocidad del Flujo Sanguíneo , Trombosis Coronaria/etiología , Trombosis Coronaria/fisiopatología , Ecocardiografía Doppler en Color/efectos adversos , Ecocardiografía Transesofágica/efectos adversos , Humanos , MasculinoRESUMEN
Usefulness of the Doppler method under continuous infusion of adenosine triphosphate disodium (ATP) for improvement of accuracy in the diagnosis of the left internal thoracic arterial graft (LITA) patency was examined using transthoracic ultrasonic echocardiography. 1) Influence of ATP on the Doppler velocity in a graft was examined in 7 patients with good LITA grafts using physiological saline as the control. In the ATP group, 80 mg of ATP was dissolved in 20 ml physiological saline and continuously infused at 0.14 mg/kg/min. In the saline group, an equal volume of physiological saline was administered and the blood flow velocity in the LITA was recorded continuously by the transthoracic Doppler method from the supraclavicular fossa approach. Results; ATP administration increased the blood flow velocity in the LITA and the rate of increase was 48.3% for systolic peak velocity, 111% for diastolic peak velocity, 64.4% for systolic time velocity integral and 99% for diastolic time velocity integral indicating particularly high rates of increase in diastolic components. The diastolic/systolic peak velocity ratio or diastolic fraction did not increase significantly. In the saline group, none of the parameters showed a change. 2) Angiographic findings of the LITA were compared with the measurement values of the diastolic components by the Doppler method to examine usefulness of diastolic component measurement with ATP infusion for diagnosis of LITA patency. Subjects were 19 patients with good LITA (group A) and 8 patients with bad LITA (group B). Results; while there were significant differences in the mean baseline diastolic peak velocity, mean diastolic time velocity integral and mean diastolic fraction between the groups, overlapping was seen in individual cases. However, the inter-group differences were more distinct by ATP infusion and the borderline values were 30 cm/sec for diastolic peak velocity and 10 for diastolic time velocity integral. 3) Reliability of the diagnosis for LITA patency by measuring the diastolic components using the Doppler method with ATP infusion was examined and compared with the angiographic findings as the gold standard. Subjects were 27 patients and the diagnostic criteria for good LITA were set at 30 cm/sec for diastolic peak velocity and 10 for diastolic time velocity integral. Results; sensitivity and specificity of the Doppler method with ATP infusion were 100% for diagnosis of LITA patency by measuring the diastolic components. Conclusion, in diagnosis of LITA patency by the transthoracic ultrasonic cardiography, diagnostic accuracy was improved by measuring the diastolic parameters under continuous infusion of ATP.