Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Clin Neurophysiol ; 161: 1-9, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38430856

RESUMEN

OBJECTIVE: Interictal biomarkers of the epileptogenic zone (EZ) and their use in machine learning models open promising avenues for improvement of epilepsy surgery evaluation. Currently, most studies restrict their analysis to short segments of intracranial EEG (iEEG). METHODS: We used 2381 hours of iEEG data from 25 patients to systematically select 5-minute segments across various interictal conditions. Then, we tested machine learning models for EZ localization using iEEG features calculated within these individual segments or across them and evaluated the performance by the area under the precision-recall curve (PRAUC). RESULTS: On average, models achieved a score of 0.421 (the result of the chance classifier was 0.062). However, the PRAUC varied significantly across the segments (0.323-0.493). Overall, NREM sleep achieved the highest scores, with the best results of 0.493 in N2. When using data from all segments, the model performed significantly better than single segments, except NREM sleep segments. CONCLUSIONS: The model based on a short segment of iEEG recording can achieve similar results as a model based on prolonged recordings. The analyzed segment should, however, be carefully and systematically selected, preferably from NREM sleep. SIGNIFICANCE: Random selection of short iEEG segments may give rise to inaccurate localization of the EZ.


Asunto(s)
Electroencefalografía , Epilepsia , Aprendizaje Automático , Humanos , Femenino , Masculino , Adulto , Epilepsia/fisiopatología , Epilepsia/diagnóstico , Electroencefalografía/métodos , Persona de Mediana Edad , Factores de Tiempo , Adulto Joven , Electrocorticografía/métodos , Electrocorticografía/normas , Adolescente , Encéfalo/fisiopatología , Fases del Sueño/fisiología
2.
Clin Neurol Neurosurg ; 212: 107054, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34896866

RESUMEN

OBJECT: Epilepsy is one of the most common clinical manifestations of primary brain tumors. Intraoperative electrocorticography (ECoG) has been widely used in tumor resection. We aim to describe the indication and utility of ECoG during brain tumor surgery. METHODS: We performed a systematic review of the literature on the prognosis of tumor-related epilepsy surgery guided by intraoperative ECoG. The published studies were searched in PubMed, Embase, and Web of Science using the keyword 'seizure' or 'epilepsy' and 'electrocorticography' or 'ECoG'. Two reviewer authors screened studies and extracted data independently. RESULTS: Thirteen studies included 569 patients were finally selected, of which eight investigated medically intractable epilepsy. Three publications described temporal tumor-related epilepsy. All included studies were retrospective, and the age of all patients ranged from 1 to 71 years. The duration of epilepsy ranged from 1 month to 30 years. Patients with tumor-related epilepsy underwent surgical treatment with Engel I outcomes ranging from 56.5%-100%. CONCLUSION: Intraoperative ECoG is generally considered a useful technique in delineating epileptogenic areas and improving the prognosis of surgical treatment of tumor-related epilepsy. However, large-scale randomized control trials are still needed to verify these findings and formulate appropriate surgical strategies.


Asunto(s)
Neoplasias Encefálicas/complicaciones , Electrocorticografía , Epilepsia/diagnóstico , Epilepsia/cirugía , Monitorización Neurofisiológica Intraoperatoria , Electrocorticografía/normas , Epilepsia/etiología , Humanos , Monitorización Neurofisiológica Intraoperatoria/normas
3.
Clin Neurophysiol ; 132(9): 2136-2145, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34284249

RESUMEN

OBJECTIVE: To assess the feasibility of automatically detecting high frequency oscillations (HFOs) in magnetoencephalography (MEG) recordings in a group of ten paediatric epilepsy surgery patients who had undergone intracranial electroencephalography (iEEG). METHODS: A beamforming source-analysis method was used to construct virtual sensors and an automatic algorithm was applied to detect HFOs (80-250 Hz). We evaluated the concordance of MEG findings with the sources of iEEG HFOs, the clinically defined seizure onset zone (SOZ), the location of resected brain structures, and with post-operative outcome. RESULTS: In 8/9 patients there was good concordance between the sources of MEG HFOs and iEEG HFOs and the SOZ. Significantly more HFOs were detected in iEEG relative to MEG t(71) = 2.85, p < .05. There was good concordance between sources of MEG HFOs and the resected area in patients with good and poor outcome, however HFOs were also detected outside of the resected area in patients with poor outcome. CONCLUSION: Our findings demonstrate the feasibility of automatically detecting HFOs non-invasively in MEG recordings in paediatric patients, and confirm compatibility of results with invasive recordings. SIGNIFICANCE: This approach provides support for the non-invasive detection of HFOs to aid surgical planning and potentially reduce the need for invasive monitoring, which is pertinent to paediatric patients.


Asunto(s)
Epilepsia Refractaria/fisiopatología , Epilepsia Refractaria/cirugía , Electrocorticografía/métodos , Electrocorticografía/normas , Electrodos Implantados/normas , Magnetoencefalografía/métodos , Adolescente , Niño , Epilepsia Refractaria/diagnóstico , Electrocorticografía/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Reproducibilidad de los Resultados
4.
Sleep Breath ; 25(4): 2251-2258, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33768413

RESUMEN

PURPOSE: During the last decade, the reported prevalence of sleep-disordered breathing in adults has been rapidly increasing. Therefore, automatic methods of sleep assessment are of particular interest. In a framework of translational neuroscience, this study introduces a reliable automatic detection system of behavioral sleep in laboratory rats based on the signal recorded at the cortical surface without requiring electromyography. METHODS: Experimental data were obtained in 16 adult male WAG/Rij rats at the age of 9 months. Electrocorticographic signals (ECoG) were recorded in freely moving rats during the entire day (22.5 ± 2.2 h). Automatic wavelet-based assessment of behavioral sleep (BS) was proposed. The performance of this wavelet-based method was validated in a group of rats with genetic predisposition to absence epilepsy (n=16) based on visual analysis of their behavior in simultaneously recorded video. RESULTS: The accuracy of automatic sleep detection was 98% over a 24-h period. An automatic BS assessment method can be adjusted for detecting short arousals during sleep (microarousals) with various duration. CONCLUSIONS: These findings suggest that automatic wavelet-based assessment of behavioral sleep can be used for assessment of sleep quality. Current analysis indicates a temporal relationship between microarousals, sleep, and epileptic discharges in genetically prone subjects.


Asunto(s)
Conducta Animal/fisiología , Corteza Cerebral/fisiología , Electrocorticografía/normas , Sueño/fisiología , Animales , Electrocorticografía/métodos , Masculino , Ratas , Sensibilidad y Especificidad , Análisis de Ondículas
5.
Epilepsia ; 62(4): 947-959, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33634855

RESUMEN

OBJECTIVE: Intracranial electroencephalography (ICEEG) recordings are performed for seizure localization in medically refractory epilepsy. Signal quantifications such as frequency power can be projected as heatmaps on personalized three-dimensional (3D) reconstructed cortical surfaces to distill these complex recordings into intuitive cinematic visualizations. However, simultaneously reconciling deep recording locations and reliably tracking evolving ictal patterns remain significant challenges. METHODS: We fused oblique magnetic resonance imaging (MRI) slices along depth probe trajectories with cortical surface reconstructions and projected dynamic heatmaps using a simple mathematical metric of epileptiform activity (line-length). This omni-planar and surface casting of epileptiform activity approach (OPSCEA) thus illustrated seizure onset and spread among both deep and superficial locations simultaneously with minimal need for signal processing supervision. We utilized the approach on 41 patients at our center implanted with grid, strip, and/or depth electrodes for localizing medically refractory seizures. Peri-ictal data were converted into OPSCEA videos with multiple 3D brain views illustrating all electrode locations. Five people of varying expertise in epilepsy (medical student through epilepsy attending level) attempted to localize the seizure-onset zones. RESULTS: We retrospectively compared this approach with the original ICEEG study reports for validation. Accuracy ranged from 73.2% to 97.6% for complete or overlapping onset lobe(s), respectively, and ~56.1% to 95.1% for the specific focus (or foci). Higher answer certainty for a given case predicted better accuracy, and scorers had similar accuracy across different training levels. SIGNIFICANCE: In an era of increasing stereo-EEG use, cinematic visualizations fusing omni-planar and surface functional projections appear to provide a useful adjunct for interpreting complex intracranial recordings and subsequent surgery planning.


Asunto(s)
Epilepsia Refractaria/diagnóstico por imagen , Epilepsia Refractaria/fisiopatología , Electrocorticografía/normas , Imagen por Resonancia Magnética/normas , Convulsiones/diagnóstico por imagen , Convulsiones/fisiopatología , Adolescente , Adulto , Encéfalo/diagnóstico por imagen , Encéfalo/fisiopatología , Niño , Preescolar , Electrocorticografía/métodos , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
6.
Epilepsia ; 61(11): 2521-2533, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32944942

RESUMEN

OBJECTIVE: High-frequency oscillations (HFOs) have shown promising utility in the spatial localization of the seizure onset zone for patients with focal refractory epilepsy. Comparatively few studies have addressed potential temporal variations in HFOs, or their role in the preictal period. Here, we introduce a novel evaluation of the instantaneous HFO rate through interictal and peri-ictal epochs to assess their usefulness in identifying imminent seizure onset. METHODS: Utilizing an automated HFO detector, we analyzed intracranial electroencephalographic data from 30 patients with refractory epilepsy undergoing long-term presurgical evaluation. We evaluated HFO rates both as a 30-minute average and as a continuous function of time and used nonparametric statistical methods to compare individual and population-level differences in rate during peri-ictal and interictal periods. RESULTS: Mean HFO rate was significantly higher for all epochs in seizure onset zone channels versus other channels. Across the 30 patients of our cohort, we found no statistically significant differences in mean HFO rate during preictal and interictal epochs. For continuous HFO rates in seizure onset zone channels, however, we found significant population-wide increases in preictal trends relative to interictal periods. Using a data-driven analysis, we identified a subset of 11 patients in whom either preictal HFO rates or their continuous trends were significantly increased relative to those of interictal baseline and the rest of the population. SIGNIFICANCE: These results corroborate existing findings that HFO rates within epileptic tissue are higher during interictal periods. We show this finding is also present in preictal, ictal, and postictal data, and identify a novel biomarker of preictal state: an upward trend in HFO rate leading into seizures in some patients. Overall, our findings provide preliminary evidence that HFOs can function as a temporal biomarker of seizure onset.


Asunto(s)
Epilepsia Refractaria/diagnóstico , Epilepsia Refractaria/fisiopatología , Electrocorticografía/métodos , Adulto , Ondas Encefálicas/fisiología , Estudios de Cohortes , Electrocorticografía/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad
7.
J Integr Neurosci ; 19(2): 259-272, 2020 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-32706190

RESUMEN

One of the challenges in brain-computer interface systems is obtaining motor imagery recognition from brain activities. Brain-signal decoding robustness and system performance improvement during the motor imagery process are two of the essential issues in brain-computer interface research. In conventional approaches, ineffective decoding of features and high complexity of algorithms often lead to unsatisfactory performance. A novel method for the recognition of motor imagery tasks is developed based on employing a modified S-transforms for spectro-temporal representation to characterize the behavior of electrocorticogram activities. A classifier is trained by using a support vector machine, and an optimized wrapper approach is applied to guide selection to implement the representation selection obtained. A channel selection algorithm optimizes the wrapper approach by adding a cross-validation step, which effectively improves the classification performance. The modified S-transform can accurately capture event-related desynchronization/event-related synchronization phenomena and can effectively locate sensorimotor rhythm information. The optimized wrapper approach used in this scheme can effectively reduce the feature dimension and improve algorithm efficiency. The method is evaluated on a public electrocorticogram dataset with a recognition accuracy of 98% and an information transfer rate of 0.8586 bit/trial. To verify the effect of the channel selection, both electrocorticogram and electroencephalogram data are experimentally analyzed. Furthermore, the computational efficiency of this scheme demonstrates its potential for online brain-computer interface systems in future cognitive tasks.


Asunto(s)
Interfaces Cerebro-Computador , Corteza Cerebral/fisiología , Electrocorticografía/métodos , Imaginación/fisiología , Actividad Motora/fisiología , Reconocimiento de Normas Patrones Automatizadas/métodos , Procesamiento de Señales Asistido por Computador , Máquina de Vectores de Soporte , Adulto , Conjuntos de Datos como Asunto , Electrocorticografía/normas , Humanos , Reconocimiento de Normas Patrones Automatizadas/normas , Máquina de Vectores de Soporte/normas
8.
Epileptic Disord ; 22(3): 291-299, 2020 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-32554357

RESUMEN

Functional connectivity is providing new insights into the network nature of epilepsy with growing clinical applications. Our objective was to validate a novel magnetoencephalography-based method to non-invasively measure the epileptic network. We retrospectively identified pediatric and adult patients with refractory focal epilepsy who underwent pre-surgical magnetoencephalography with subsequent intracranial electrographic monitoring. Magnetoencephalography tracings were visually reviewed, and interictal epileptiform discharges ("spikes") were individually marked. We then evaluated differences in whole-brain connectivity during brief epochs preceding the spikes and during the spikes using the Network-Based Statistic to test differences at the network level. In six patients with statistically-significant network differences, we observed substantial overlap between the spike-associated networks and electrographically active areas identified during intracranial monitoring (the spike-associated network was 78% and 83% sensitive for intracranial electroencephalography-defined regions in the irritative and seizure onset zones, respectively). These findings support the neurobiological validity of the spike-associated network method. Assessment of spike-associated networks has the potential to improve surgical planning in epilepsy surgery patients by identifying components of the epileptic network prior to implantation.


Asunto(s)
Conectoma/normas , Epilepsia Refractaria/fisiopatología , Electrocorticografía/normas , Epilepsias Parciales/fisiopatología , Magnetoencefalografía/normas , Red Nerviosa/fisiopatología , Adolescente , Adulto , Niño , Epilepsia Refractaria/diagnóstico , Epilepsias Parciales/diagnóstico , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
10.
Ann Clin Transl Neurol ; 7(3): 329-342, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32096612

RESUMEN

OBJECTIVE: To assess the ability of high-density Electroencephalography (HD-EEG) and magnetoencephalography (MEG) to localize interictal ripples, distinguish between ripples co-occurring with spikes (ripples-on-spike) and independent from spikes (ripples-alone), and evaluate their localizing value as biomarkers of epileptogenicity in children with medically refractory epilepsy. METHODS: We retrospectively studied 20 children who underwent epilepsy surgery. We identified ripples on HD-EEG and MEG data, localized their generators, and compared them with intracranial EEG (icEEG) ripples. When ripples and spikes co-occurred, we performed source imaging distinctly on the data above 80 Hz (to localize ripples) and below 70 Hz (to localize spikes). We assessed whether missed resection of ripple sources predicted poor outcome, separately for ripples-on-spikes and ripples-alone. Similarly, predictive value of spikes was calculated. RESULTS: We observed scalp ripples in 16 patients (10 good outcome). Ripple sources were highly concordant to the icEEG ripples (HD-EEG concordance: 79%; MEG: 83%). When ripples and spikes co-occurred, their sources were spatially distinct in 83-84% of the cases. Removing the sources of ripples-on-spikes predicted good outcome with 90% accuracy for HD-EEG (P = 0.008) and 86% for MEG (P = 0.044). Conversely, removing ripples-alone did not predict outcome. Resection of spike sources (generated at the same time as ripples) predicted good outcome for HD-EEG (P = 0.036; accuracy = 87%), while did not reach significance for MEG (P = 0.1; accuracy = 80%). INTERPRETATION: HD-EEG and MEG localize interictal ripples with high precision in children with refractory epilepsy. Scalp ripples-on-spikes are prognostic, noninvasive biomarkers of epileptogenicity, since removing their cortical generators predicts good outcome. Conversely, scalp ripples-alone are most likely generated by non-epileptogenic areas.


Asunto(s)
Epilepsia Refractaria/diagnóstico , Epilepsia Refractaria/cirugía , Electroencefalografía/normas , Magnetoencefalografía/normas , Procedimientos Neuroquirúrgicos/normas , Evaluación de Resultado en la Atención de Salud/normas , Adolescente , Biomarcadores , Ondas Encefálicas/fisiología , Niño , Epilepsia Refractaria/fisiopatología , Electrocorticografía/normas , Femenino , Humanos , Lactante , Masculino , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Cuero Cabelludo
11.
Neuroimage ; 211: 116597, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32018004

RESUMEN

Ultrasound-mediated neuromodulation is emerging as a key technology for targeted noninvasive brain stimulation, but key insights into its effects and dose-response characteristics are still missing. The purpose of this study is to systematically evaluate the effect of low-intensity transcranial ultrasound stimulation (TUS) on complementary aspects of cerebral hemodynamic. We simultaneously record the EMG signal, local field potential (LFP) and cortical blood flow (CBF) using electrophysiological recording and laser speckle contrast imaging under ultrasound stimulation to simultaneously monitor motor responses, neural activities and hemodynamic changes during the application of low-intensity TUS in mouse motor cortex, using excitation pulses which caused whisker and tail movement. Our experimental results demonstrate interdependent TUS-induced motor, neural activity and hemodynamic responses that peak approximately 0.55s, 1.05s and 2.5s after TUS onset, respectively, and show a linear coupling relationship between their respective varying response amplitudes to repeated stimuli. We also found monotonic dose-response parametric relations of the CBF peak value increase as a function of stimulation intensity and duration, while stimulus duty-cycle had only a weak effect on peak responses. These findings demonstrate that TUS induces a change in cortical hemodynamics and LSCI provide a high temporal resolution view of these changes.


Asunto(s)
Electrocorticografía/métodos , Fenómenos Electrofisiológicos/fisiología , Imágenes de Contraste de Punto Láser/métodos , Corteza Motora/fisiología , Neuroimagen/métodos , Acoplamiento Neurovascular/fisiología , Ondas Ultrasónicas , Animales , Conducta Animal/fisiología , Electrocorticografía/normas , Electromiografía/métodos , Electromiografía/normas , Imágenes de Contraste de Punto Láser/normas , Masculino , Ratones , Ratones Endogámicos BALB C , Corteza Motora/diagnóstico por imagen , Movimiento/fisiología , Neuroimagen/normas , Estimulación Física , Cola (estructura animal)/fisiología , Factores de Tiempo , Terapia por Ultrasonido , Vibrisas/fisiología
12.
J Clin Neurosci ; 71: 158-163, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31521471

RESUMEN

Numerous non-epileptic physiological electroencephalographic (EEG) patterns morphologically mimic epileptiform activity. However, misleading non-epileptic findings of electrocorticography (ECoG) have not yet been examined in detail. The aim of the present study was to identify non-epileptic epileptiform ECoG findings. We retrospectively reviewed the intracranial recordings of 21 patients with intractable focal epilepsy who became seizure-free after a presurgical evaluation with subdural electrodes following resective surgeries at Sapporo Medical University between January 2014 and December 2018. Morphological epileptiform findings outside epileptogenic areas were judged as non-epileptic and analyzed. Seventeen areas in nine patients exhibited non-epileptic epileptiform activities. These areas were identified in the lateral temporal cortices, basal temporal areas, rolandic areas, and frontal lobe. Morphological patterns were classified into three types: 1) spiky oscillations, 2) isolated spiky activity, and 3) isolated fast activity. The normal cortex may exhibit non-epileptic epileptiform activities. These activities need to be carefully differentiated from real epileptic abnormalities to prevent the mislocalization of epileptogenic areas.


Asunto(s)
Electrocorticografía/métodos , Epilepsia/fisiopatología , Adulto , Errores Diagnósticos , Electrocorticografía/normas , Epilepsia/diagnóstico , Femenino , Lóbulo Frontal/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Lóbulo Temporal/fisiopatología
13.
Epilepsy Behav ; 103(Pt A): 106843, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31882325

RESUMEN

INTRODUCTION: The choice of subdural grid (SDG) or stereoelectroencephalography (sEEG) for patients with epilepsy can be complex and in some cases overlap. Comparing postoperative pain and narcotics consumption with SDG or sEEG can help develop an intracranial monitoring strategy. MATERIALS AND METHODS: A retrospective study was performed for adult patients undergoing SDG or sEEG monitoring. Numeric Rating Scale (NRS) was used for pain assessment. Types and dosage of the opioids were calculated by converting into milligram morphine equivalents (MME). Narcotic consumption was analyzed at the following three time periods: I. the first 24 h of implantation; II. from the second postimplantation day to the day of explantation; and III. the days following electrode removal to discharge. RESULTS: Forty-two patients who underwent SDG and 31 patients who underwent sEEG implantation were analyzed. After implantation, average NRS was 3.7 for SDG and 2.2 for sEEG (P < .001). After explantation, the NRS was 3.5 for SDG and 1.4 in sEEG (P < .001). Sixty percent of SDG patients and 13% of sEEG patients used more than one opioid in period III (P < .001). The SDG group had a significantly higher MME throughout the three periods compared with the sEEG group: period I: 448 (SDG) vs. 205 (sEEG) mg, P = .002; period II: 377 (SDG) vs. 102 (sEEG) mg, P < .001; and period III: 328 (SDG) vs. 75 (sEEG) mg; P = .002. Patients with the larger SDG implantation had the higher NRS (P = .03) and the higher MME at period I (P = .019). There was no correlation between the number of depth electrodes and pain control in patients with sEEG. CONCLUSIONS: Patients undergoing sEEG had significantly less pain and required fewer opiates compared with patients with SDG. These differences in perioperative pain may be a consideration when choosing between these two invasive monitoring options.


Asunto(s)
Analgésicos Opioides/administración & dosificación , Electrocorticografía/métodos , Electrodos Implantados , Electroencefalografía/métodos , Dolor Postoperatorio/tratamiento farmacológico , Técnicas Estereotáxicas , Adulto , Epilepsia Refractaria/diagnóstico por imagen , Epilepsia Refractaria/tratamiento farmacológico , Epilepsia Refractaria/cirugía , Electrocorticografía/normas , Electrodos Implantados/normas , Electroencefalografía/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Narcóticos/administración & dosificación , Dimensión del Dolor/métodos , Dimensión del Dolor/normas , Dolor Postoperatorio/diagnóstico por imagen , Estudios Retrospectivos , Técnicas Estereotáxicas/normas
14.
Seizure ; 77: 64-68, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30711397

RESUMEN

Stereoelectroencephalography-guided radiofrequency-thermocoagulation (SEEG-guided RF-TC) consists of coupling SEEG investigation with RF-TC stereotactic lesioning directly through the recording electrodes. In this systematic review the surgical technique, indications, and outcomes are described. Maximum accuracy is reached when a frame-based procedure with a robotic assistance and a per-operative vascular X-ray imaging are performed. Monitoring of the lesioning procedure based on the impedance, a sharp modification of which indicates that the thermocoagulation has reached its maximum volume, allows the optimization of the lesion size. The first indication concerns patients in whom a SEEG is required to determine whether surgery is feasible and in whom resection is indeed possible. Even if surgery is performed owing to insufficient efficacy of SEEG-guided RF-TC, the procedure remains interesting owing to its high positive predictive value for good outcome after surgery. The second indication concerns patients in whom phase I non-invasive investigations have concluded to surgical contraindication and who may still undergo SEEG in a purely therapeutic perspective (small deep zones inaccessible to surgery and network nodes of large epileptic networks). Lastly, SEEG-guided RF-TC can be considered as a first-line treatment for periventricular nodular heterotopia (PNH). Independently of indication, the overall seizure-free rate is 23% and the responder rate is 58%. The best results are obtained for PNH (38% seizure-free and 81% responders), while the worst results have been reported for temporal lobe-epilepsy in a dedicated study. The overall complication rate is 2.5%. More evidence is needed to help determine the exact place of SEEG-guided RF-TC in the surgical management algorithm.


Asunto(s)
Epilepsia Refractaria/cirugía , Electrocoagulación , Electrocorticografía , Epilepsias Parciales/cirugía , Heterotopia Nodular Periventricular/cirugía , Técnicas Estereotáxicas , Electrocoagulación/métodos , Electrocoagulación/normas , Electrocorticografía/métodos , Electrocorticografía/normas , Humanos , Técnicas Estereotáxicas/normas
15.
Seizure ; 77: 52-58, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31101405

RESUMEN

Efforts to improve epilepsy surgery outcomes have led to increased interest in the study of electroencephalographic oscillations outside the conventional EEG bands. These include fast activity above the gamma band, known as high frequency oscillations (HFOs), and infraslow activity (ISA) below the delta band, sometimes referred to as direct current (DC) or ictal baseline shifts (IBS). HFOs in particular have been extensively studied as potential biomarkers for epileptogenic tissue in light of evidence showing that resection of brain tissue containing HFOs is associated with good surgical outcomes. Not all HFOs are conclusively pathological, however, as they can be recorded in nonepileptic tissue and induced by cognitive, visual, or motor tasks. Consequently, efforts to distinguish between pathological and physiological HFOs have identified several traits specific to pathological HFOs, such as coupling with interictal spikes, association with delta waves, and stereotypical morphologies. On the opposite end of the EEG spectrum, sub-delta oscillations have been shown to co-localize with the seizure onset zones (SOZ) and appear in a narrower spatial distribution than activity in the conventional EEG frequency bands. In this report, we review studies that implicate HFOs and ISA in ictogenesis and discuss current limitations such as inter-observer variability and poor standardization of recording techniques. Furthermore, we propose that HFOs and ISA should be analyzed in addition to activity in the conventional EEG band during intracranial presurgical EEG monitoring to identify the best possible surgical margin.


Asunto(s)
Ondas Encefálicas/fisiología , Electrocorticografía , Epilepsia/diagnóstico , Epilepsia/fisiopatología , Electrocorticografía/métodos , Electrocorticografía/normas , Epilepsia/cirugía , Humanos
16.
Seizure ; 77: 59-63, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31445890

RESUMEN

Electrical stimulation mapping is a longstanding practice that aids in identification and delineation of eloquent cortex. Initially used to expand our understanding of the typical human cortex, it now plays a significant role in mapping cortical function in individuals with atypical structural and functional tissue organization undergoing epilepsy surgery. This review discusses the unique challenges that arise in the functional testing of the immature cortex of a child and the parameters of stimulation that optimize accurate results in conventional open implantation and in stereo-electroencephalography. The prerequisite baseline evaluation and preparation recommended to increase the yield from pediatric stimulation mapping sessions is described, as are ideal approaches to the mapping of the sensory, motor, language, and visual cortices.


Asunto(s)
Mapeo Encefálico , Corteza Cerebral , Estimulación Eléctrica , Electrocorticografía , Epilepsia/cirugía , Potenciales Evocados , Monitoreo Intraoperatorio , Procedimientos Neuroquirúrgicos , Mapeo Encefálico/métodos , Mapeo Encefálico/normas , Corteza Cerebral/fisiopatología , Niño , Estimulación Eléctrica/métodos , Electrocorticografía/métodos , Electrocorticografía/normas , Potenciales Evocados/fisiología , Humanos , Monitoreo Intraoperatorio/métodos , Monitoreo Intraoperatorio/normas , Procedimientos Neuroquirúrgicos/métodos , Procedimientos Neuroquirúrgicos/normas
17.
Seizure ; 77: 43-51, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30503504

RESUMEN

Designed from the 60s to the 80s for adults, and despite the development of many new techniques, invasive explorations still have indications in children with focal drug-resistant epilepsy. The main types are stereoelectroencephalography (SEEG) and subdural explorations (SDE). They provide precise information on the localization of the epileptogenic zone (EZ), its relationships with eloquent cortex, and the feasibility of performing a tailored surgical resection. Thermocoagulations, which are a diagnostic and therapeutic tool, can be performed using SEEG electrodes. Both techniques are feasible in children, with an age limitation for SEEG (which requires a bone thickness above 2 mm). The complication rate is higher with SDE. Opposed for a long time and never compared in a systematic study, they should presently be considered complementary. The indications cannot be directly inferred from those for adults, as there are pediatric particularities in the seizures' semiology, functional areas, imaging and urgent situations. We successively discuss the choice in individual cases of SEEG or SDE respectively, the specific problematic in infancy and early childhood, the schema in SEEG for cryptogenic epilepsies (in particular insular), the particularities of polymicrogyria and deeply located lesions, and finally, SEEG designed for thermocoagulations. Future improvements should include more accurate implantation schemas thanks to advanced non-invasive explorations and possibilities to perform SEEG in infants.


Asunto(s)
Epilepsia Refractaria/diagnóstico , Electrocoagulación , Electrocorticografía , Epilepsias Parciales/diagnóstico , Técnicas Estereotáxicas , Adolescente , Niño , Preescolar , Epilepsia Refractaria/patología , Epilepsia Refractaria/cirugía , Electrocoagulación/métodos , Electrocoagulación/normas , Electrocorticografía/métodos , Electrocorticografía/normas , Epilepsias Parciales/patología , Epilepsias Parciales/cirugía , Humanos , Técnicas Estereotáxicas/normas
18.
Hum Brain Mapp ; 41(3): 797-814, 2020 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-31692177

RESUMEN

Resting-state functional magnetic resonance imaging (rsfMRI) is a promising task-free functional imaging approach, which may complement or replace task-based fMRI (tfMRI) in patients who have difficulties performing required tasks. However, rsfMRI is highly sensitive to head movement and physiological noise, and validation relative to tfMRI and intraoperative electrocortical mapping is still necessary. In this study, we investigate (a) the feasibility of real-time rsfMRI for presurgical mapping of eloquent networks with monitoring of data quality in patients with brain tumors and (b) rsfMRI localization of eloquent cortex compared with tfMRI and intraoperative electrocortical stimulation (ECS) in retrospective analysis. Five brain tumor patients were studied with rsfMRI and tfMRI on a clinical 3T scanner using MultiBand(8)-echo planar imaging (EPI) with repetition time: 400 ms. Moving-averaged sliding-window correlation analysis with regression of motion parameters and signals from white matter and cerebrospinal fluid was used to map sensorimotor and language resting-state networks. Data quality monitoring enabled rapid optimization of scan protocols, early identification of task noncompliance, and head movement-related false-positive connectivity to determine scan continuation or repetition. Sensorimotor and language resting-state networks were identifiable within 1 min of scan time. The Euclidean distance between ECS and rsfMRI connectivity and task-activation in motor cortex, Broca's, and Wernicke's areas was 5-10 mm, with the exception of discordant rsfMRI and ECS localization of Wernicke's area in one patient due to possible cortical reorganization and/or altered neurovascular coupling. This study demonstrates the potential of real-time high-speed rsfMRI for presurgical mapping of eloquent cortex with real-time data quality control, and clinically acceptable concordance of rsfMRI with tfMRI and ECS localization.


Asunto(s)
Mapeo Encefálico/normas , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Corteza Cerebral/diagnóstico por imagen , Imagen de Difusión Tensora/normas , Imagen Eco-Planar/normas , Electrocorticografía/normas , Red Nerviosa/diagnóstico por imagen , Cuidados Preoperatorios , Adulto , Mapeo Encefálico/métodos , Corteza Cerebral/fisiología , Imagen de Difusión Tensora/métodos , Imagen Eco-Planar/métodos , Estimulación Eléctrica/métodos , Electrocorticografía/métodos , Estudios de Factibilidad , Femenino , Humanos , Monitorización Neurofisiológica Intraoperatoria/métodos , Monitorización Neurofisiológica Intraoperatoria/normas , Lenguaje , Masculino , Persona de Mediana Edad , Red Nerviosa/fisiología , Corteza Sensoriomotora/diagnóstico por imagen , Corteza Sensoriomotora/fisiología
19.
Neuroimage ; 208: 116431, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31816421

RESUMEN

Comparing electric field simulations from individualized head models against in-vivo intra-cranial recordings is considered the gold standard for direct validation of computational field modeling for transcranial brain stimulation and brain mapping techniques such as electro- and magnetoencephalography. The measurements also help to improve simulation accuracy by pinning down the factors having the largest influence on the simulations. Here we compare field simulations from four different automated pipelines against intracranial voltage recordings in an existing dataset of 14 epilepsy patients. We show that modeling differences in the pipelines lead to notable differences in the simulated electric field distributions that are often large enough to change the conclusions regarding the dose distribution and strength in the brain. Specifically, differences in the automatic segmentations of the head anatomy from structural magnetic resonance images are a major factor contributing to the observed field differences. However, the differences in the simulated fields are not reflected in the comparison between the simulations and intra-cranial measurements. This apparent mismatch is partly explained by the noisiness of the intra-cranial measurements, which renders comparisons between the methods inconclusive. We further demonstrate that a standard regression analysis, which ignores uncertainties in the simulations, leads to a strong bias in the estimated linear relationship between simulated and measured fields. Ignoring this bias leads to the incorrect conclusion that the models systematically misestimate the field strength in the brain. We propose a new Bayesian regression analysis of the data that yields unbiased parameter estimates, along with their uncertainties, and gives further insights to the fit between simulations and measurements. Specifically, the unbiased results give only weak support for systematic misestimations of the fields by the models.


Asunto(s)
Encéfalo , Electrocorticografía , Modelos Teóricos , Neuroimagen , Estimulación Transcraneal de Corriente Directa , Adulto , Teorema de Bayes , Encéfalo/anatomía & histología , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Electrocorticografía/normas , Epilepsia/diagnóstico , Humanos , Imagen por Resonancia Magnética , Neuroimagen/normas , Análisis de Regresión , Estimulación Transcraneal de Corriente Directa/normas , Estudios de Validación como Asunto
20.
Clin Neurophysiol ; 131(1): 133-141, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31760212

RESUMEN

OBJECTIVE: Develop a high-performing algorithm to detect mesial temporal lobe (mTL) epileptiform discharges on intracranial electrode recordings. METHODS: An epileptologist annotated 13,959 epileptiform discharges from a dataset of intracranial EEG recordings from 46 epilepsy patients. Using this dataset, we trained a convolutional neural network (CNN) to recognize mTL epileptiform discharges from a single intracranial bipolar channel. The CNN outputs from multiple bipolar channel inputs were averaged to generate the final detector output. Algorithm performance was estimated using a nested 5-fold cross-validation. RESULTS: On the receiver-operating characteristic curve, our algorithm achieved an area under the curve (AUC) of 0.996 and a partial AUC (for specificity > 0.9) of 0.981. AUC on a precision-recall curve was 0.807. A sensitivity of 84% was attained at a false positive rate of 1 per minute. 35.9% of the false positive detections corresponded to epileptiform discharges that were missed during expert annotation. CONCLUSIONS: Using deep learning, we developed a high-performing, patient non-specific algorithm for detection of mTL epileptiform discharges on intracranial electrodes. SIGNIFICANCE: Our algorithm has many potential applications for understanding the impact of mTL epileptiform discharges in epilepsy and on cognition, and for developing therapies to specifically reduce mTL epileptiform activity.


Asunto(s)
Algoritmos , Aprendizaje Profundo , Electrocorticografía/instrumentación , Electrodos Implantados , Epilepsia del Lóbulo Temporal/fisiopatología , Lóbulo Temporal/fisiopatología , Adulto , Área Bajo la Curva , Artefactos , Conjuntos de Datos como Asunto , Electrocorticografía/métodos , Electrocorticografía/normas , Epilepsia del Lóbulo Temporal/diagnóstico , Femenino , Foramen Oval/fisiopatología , Humanos , Masculino , Curva ROC , Estándares de Referencia , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...