Resultados 1 - 20 de 1.389
Filtrar
1.
ACS Sens ; 9(8): 3870-3876, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39115965

RESUMEN

Ion-selective electrodes (ISEs) have widespread use in the fields of clinical and environmental analyses. Tetrahydrofuran (THF) is the most used solvent for the preparation of modern ISEs, equipped with ion-selective membranes (ISMs). Until now, the influence of impurities in THF toward potentiometric instability of ion-selective membrane based ISEs was probably associated with the presence of either residual water or peroxide. To address this issue, most literature recommends redistilling THF prior to use in the preparation of the potentiometric membranes. Current study reveals that the actual THF impurity that is responsible for potential instability in the ISM includes products from the oxidation of THF, which contains the hydroxyl group and possibly carbonyl group with a boiling point of above 200 °C. The density functional theory calculation supported pathway of the chemical reaction of THF oxidation, hence, the chemical structure of the uncertain impurities was predicted. The underlying reason for the deteriorating potential stability of the ISEs is proposed as the significant hydrophilicity of these impurities that affect the partitioning of the ion sensing components in the membrane, thus enhancing the leaching of the membrane components from the membrane phase. This finding explains why redistillation of aged THF is advised.


Asunto(s)
Furanos , Furanos/química , Electrodos de Iones Selectos , Oxidación-Reducción , Membranas Artificiales , Potenciometría , Teoría Funcional de la Densidad
2.
Anal Chim Acta ; 1321: 343042, 2024 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-39155097

RESUMEN

BACKGROUND: The local pH change mediated by the pathogenic bacterial species Streptococcus mutans plays a significant role in the corrosion of hydroxyapatite (HA) present in the tooth in the dynamic oral cavity. The acid produced by the bacteria decreases the local pH and releases Ca2+ ions from the HA. We studied the bacteria-mediated demineralization of HA by scanning electrochemical microscopy (SECM) after growing S. mutans biofilm on HA for 7 days. RESULTS: We notably developed a triple-function SECM-compatible tip that could be positioned above the biofilm. It can also measure the pH and [Ca2+] change simultaneously above the biofilm-HA substrate. The triple-function SECM tip is a combination of a potentiometric pH sensor deposited with iridium oxide and a dual-function carbon-based Ca2+ ion-selective membrane electrode with a slope of 67 mV/pH and 34.3 mV/log [Ca2+], respectively. The distance-controlled triple-function SECM tip monitored real-time pH and [Ca2+] changes 30 µm above the S. mutans biofilm. The high temporal resolution pH data demonstrated that after approximately 20 min of sucrose addition, S. mutans started to produce acid to titrate the solution buffer, causing a pH change from 7.2 to 6.5 for HA and from 7.2 to 5 for the glass substrate. We observed that, after 30 min of acid production, ∼300 µM of Ca2+ ions were increased at pH 6.5 above the biofilm surface as a result of the pH change in the local microenvironment. After the release of Ca2+ from HA, the pH environment again shifted toward the neutral side, from 6.5 to 7.2. Therefore, precipitation of Ca2+ happens at the top of the biofilm, thus corroding the HA from underneath. For a glass substrate, in contrast, no Ca2+ ions were released, and the pH did not change back to 7.2. We were able to observe the dynamics of the HA demineralization-remineralization process simultaneously with our newly developed triple-function SECM tip or microprobe. SIGNIFICANCE: This technique could notably advance the study of similar complex processes, such as bacteria-mediated corrosion in biomedical and environmental contexts.


Asunto(s)
Biopelículas , Calcio , Carbono , Durapatita , Microelectrodos , Streptococcus mutans , Streptococcus mutans/metabolismo , Concentración de Iones de Hidrógeno , Durapatita/química , Calcio/química , Calcio/metabolismo , Carbono/química , Corrosión , Electrodos de Iones Selectos
3.
Lab Chip ; 24(17): 4096-4104, 2024 08 20.
Artículo en Inglés | MEDLINE | ID: mdl-39086302

RESUMEN

Electrochemical sensors provide an affordable and reliable approach towards the detection and monitoring of important biological species ranging from simple ions to complex biomolecules. The ability to miniaturize electrochemical sensors, coupled with their affordability and simple equipment requirements for signal readout, permits the use of these sensors at the point-of-care where analysis using non-invasively obtainable biofluids is receiving growing interest by the research community. This paper describes the design, fabrication, and integration of a 3D printed Mg2+ potentiometric sensor into a 3D printed microfluidic device for the quantification of Mg2+ in low-sample volume biological fluids. The sensor employs a functionalized 3D printable photocurable methacrylate-based ion-selective membrane affixed to a carbon-mesh/epoxy solid-contact transducer for the selective determination of Mg2+ in sweat, saliva and urine. The 3D printed Mg2+ ion-selective electrode (3Dp-Mg2+-ISE) provided a Nernstian response of 27.5 mV per decade with a linear range of 10 mM to 39 µM, covering the normal physiological and clinically relevant levels of Mg2+ in biofluids. 3Dp-Mg2+-ISEs selectively measure Mg2+ over other biologically present cations - sodium, potassium, calcium, ammonium - as well as provide high stability in the analytical signal with a drift of just 13 µV h-1 over 10 hours. Comparison with poly(vinylchloride)-based Mg2+-ISEs showed distinct advantages to the use of 3Dp-Mg2+-ISEs, with respect to stability, resilience towards biofouling and importantly providing a streamlined and rapid approach towards mass production of selective and reliable sensors. The miniaturization capabilities of 3D printing coupled with the benefits of microfluidic analysis (i.e., low sample volumes, minimal reagent consumption, automation of multiple assays, etc.), provides exciting opportunities for the realization of the next-generation of point-of-care diagnostic devices.


Asunto(s)
Dispositivos Laboratorio en un Chip , Magnesio , Impresión Tridimensional , Magnesio/química , Humanos , Potenciometría/instrumentación , Diseño de Equipo , Técnicas Analíticas Microfluídicas/instrumentación , Electrodos de Iones Selectos , Saliva/química
4.
J Dent ; 148: 105247, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-39025427

RESUMEN

OBJECTIVE: To assess the fluoride and silver ion release of glass ionomer cement (GIC) restorations, including conventional GIC (CGIC) and resin-modified GIC (RMGIC) restorations, with 38 % silver diamine fluoride (SDF) solution dentin pretreatment. METHODS: Eighty dentin blocks were allocated into 4 groups and restored with SDF+CGIC, CGIC, SDF+RMGIC and RMGIC, respectively. Each block was stored in deionized water at 37 °C for 2 years. Fluoride and silver ion concentration in storage solution was measured using ion-selective electrode and inductively coupled plasma-optical emission spectrometry for up to 2 years. The cross-sectional surfaces of restored dentin blocks were assessed by X-Ray diffraction analysis (XRD), scanning electron microscope (SEM) with energy-dispersive X-ray spectroscopy (EDS) after 1 week and 2 years, respectively. RESULTS: The mean ± standard deviation (SD) of accumulative fluoride releasing in SDF+CGIC, CGIC, SDF+RMGIC and RMGIC for 2 years were 0.13±0.005 mg, 0.09±0.006 mg, 0.15±0.008 mg and 0.05±0.003 mg, respectively (Groups SDF+RMGIC > SDF+CGIC > CGIC >RMGIC, p < 0.05). The mean ± SD of accumulative silver releasing in SDF+CGIC, CGIC, SDF+RMGIC and RMGIC for 2 years were 0.03±0.009 mg, 0.00±0.00 mg, 0.01±0.003 mg, and 0.00±0.00 mg, respectively (Groups SDF+CGIC > SDF+RMGIC > CGIC&RMGIC, p < 0.05). Groups SDF+CGIC and SDF+RMGIC showed sustainably higher fluoride and silver releasing compared to Groups CGIC and RMGIC (p < 0.05). XRD analysis indicated the fluorapatite and silver chloride were observed only in Groups SDF+CGIC and SDF+RMGIC, but not in Groups CGIC and RMGIC. SEM images of the cross-sectional view of the dentin blocks showed silver crystals within dentinal tubules 1 week and 2-year in Groups with SDF pretreatment. CONCLUSION: The 38 % SDF dentin pretreatment sustainably increased the fluoride and silver release of GIC and RMGIC restorations for up to 2 years.


Asunto(s)
Dentina , Fluoruros Tópicos , Fluoruros , Cementos de Ionómero Vítreo , Microscopía Electrónica de Rastreo , Compuestos de Amonio Cuaternario , Compuestos de Plata , Plata , Espectrometría por Rayos X , Difracción de Rayos X , Compuestos de Plata/química , Compuestos de Amonio Cuaternario/química , Cementos de Ionómero Vítreo/química , Dentina/química , Dentina/efectos de los fármacos , Fluoruros/química , Fluoruros Tópicos/química , Humanos , Plata/química , Cariostáticos/química , Ensayo de Materiales , Restauración Dental Permanente/métodos , Electrodos de Iones Selectos , Cementos de Resina/química , Propiedades de Superficie
5.
Eur Arch Paediatr Dent ; 25(3): 409-415, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38635111

RESUMEN

PURPOSE: The purpose of the study was to determine the fluoride (F) and silver (Ag) ions levels in the saliva and urine of healthy children after silver diamine fluoride (SDF) application on dental carious lesions. METHODS: Sixty children (4-6 years with ≥ 3 caries lesions) were recruited from the outpatient department of Pediatric Dentistry. From each child, 3 ml unstimulated saliva samples were collected at baseline, one hour, and 24 h after SDF application. Similarly, 3 ml urine samples were collected prior to and after 24 h of SDF application. F and Ag ion concentrations were determined by fluoride ion-selective electrode (ISE) and inductively coupled plasma mass spectrometry (ICPMS), respectively. RESULTS: The mean ± standard deviation (SD) baseline, 1-h, and 24-h salivary F concentrations (ppm) were 0.07 ± 0.07, 0.93 ± 0.48, and 0.19 ± 0.19, respectively, while the mean baseline and 24-h urinary F concentrations (ppm) were 0.33 ± 0.20 ppm and 0.43 ± 0.25 ppm, respectively. The mean baseline, 1-h, and 24-h salivary Ag concentrations (ppb) were 4.22 ± 3.15, 4198 ± 350, and 56.93 ± 37, respectively. The mean baseline and 24-h urinary Ag concentrations (ppb) were 2.80 ± 2.93 ppb and 4.72 ± 4.0 ppb, respectively. There were statistically elevated F and Ag ion concentrations at 1 h and 24 h after SDF application as compared to the baseline. CONCLUSION: Salivary and urinary F and Ag ions concentrations elevated significantly at 24 h following SDF applications in children. A significant high recovery of these ions in urine indicates minimal systemic absorption, thus intermittent topical application of 38% SDF has a minimal risk of toxicity.


Asunto(s)
Fluoruros Tópicos , Fluoruros , Compuestos de Amonio Cuaternario , Saliva , Compuestos de Plata , Plata , Humanos , Saliva/química , Fluoruros Tópicos/administración & dosificación , Niño , Preescolar , Estudios Prospectivos , Femenino , Masculino , Fluoruros/análisis , Fluoruros/orina , Compuestos de Amonio Cuaternario/análisis , Compuestos de Amonio Cuaternario/administración & dosificación , Caries Dental , Cariostáticos/análisis , Cariostáticos/administración & dosificación , Electrodos de Iones Selectos
6.
J AOAC Int ; 107(4): 549-557, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38627224

RESUMEN

BACKGROUND: Through the use of sustainable and green chemistry concepts, scientists need to decrease waste, conserve energy, and develop safe substitutes for hazardous compounds, all for protecting and benefiting society and the environment. OBJECTIVE: Four novel eco-friendly ion selective electrodes (ISE) were generated to determine Ethamsylate (ETM) in bulk powder and different pharmaceutical formulations. The present electrodes were fabricated to clearly distinguish ETM from a variety of inorganic, organic ions, sugars, some common drug excipients and the degradation product, hydroquinone (HQ) of ETM, and thus used for stability-indicating methods. METHODS: The electrodes fabrication was based on 2-nitrophenyl octyl ether (NPOE) that was employed as a plasticizer in electrodes 1, 2, and 3 within a polymeric matrix of polyvinyl chloride (PVC) except for electrode 4, in which dibutyl sebacate was used as a plasticizer. Electrodes 1 and 2 were fabricated using tetradodecylammonium bromide as an anionic exchanger, adding 4-sulfocalix-8-arene as an ionophore only to electrode 2 and preparing electrode 1 without incorporation of an ionophore. The fabrication of electrodes 3 and 4 was based on ethamsylate-tetraphenylborate (ETM-TPB) as an ion-association complex in a PVC matrix. The environmental sustainability was assessed using the green analytical procedure index (GAPI), and analytical greenness metric for sample preparation (AGREEprep). RESULTS: Electrodes 1 and 2 had linear dynamic ranges of 10-1-10-5 mol/L and 10-1-10-4 mol/L, respectively, with a Nernstian slope of 49.6 and 53.2 mV/decade, respectively. Electrodes 3 and 4 had linear dynamic ranges of 10-1-10-4 mol/L, with a Nernstian slope of 43.9 and 40.2 mV/decade, respectively. CONCLUSION: The electrodes' selectivity coefficients showed good selectivity for ETM. The utility of 4-sulfocalix-8-arene as an ionophore had a significant influence on increasing the membrane sensitivity and selectivity of electrode 2 compared to other electrodes. HIGHLIGHTS: Four novel eco-friendly ISEs were used for determination of ETM in bulk powder and different pharmaceutical formulations. Different experimental parameters were performed to optimize the determination conditions such as solvent mediators, dynamic response time, effect of pH, and temperature. Stability-indicating measurement of ETM in the presence of its degradate HQ and co-formulated drug tranexamic acid. Using new ecological assessment tools to determine whiteness and greenness profiles.


Asunto(s)
Electrodos de Iones Selectos , Potenciometría , Potenciometría/métodos , Tecnología Química Verde/métodos , Plastificantes/química , Plastificantes/análisis , Estabilidad de Medicamentos , Cloruro de Polivinilo/química , Éteres
7.
Anal Chim Acta ; 1305: 342590, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38677844

RESUMEN

Monitoring extracellular calcium ion (Ca2+) chemical signals in neurons is crucial for tracking physiological and pathological changes associated with brain diseases in live animals. Potentiometry based solid-state ion-selective electrodes (ISEs) with the assist of functional carbon nanomaterials as ideal solid-contact layer could realize the potential response for in vitro and in vivo analysis. Herein, we employ a kind of biomass derived porous carbon as a transducing layer to prompt efficient ion to electron transduction while stabilizes the potential drift. The eco-friendly porous carbon after activation (APB) displays a high specific area with inherit macropores, micropores, and large specific capacitance. When employed as transducer in ISEs, a stable potential response, minimized potential drift can be obtained. Benefiting from these excellent properties, a solid-state Ca2+ selective carbon fiber electrodes (CFEs) with a sandwich structure is constructed and employed for real time sensing of Ca2+ under electrical stimulation. This study presents a new approach to develop sustainable and versatile transducers in solid-state ISEs, a crucial way for in vivo sensing.


Asunto(s)
Calcio , Carbono , Nanoestructuras , Calcio/química , Calcio/análisis , Carbono/química , Nanoestructuras/química , Electrodos de Iones Selectos , Animales , Porosidad , Transductores , Técnicas Electroquímicas/instrumentación
8.
Methods Enzymol ; 696: 43-63, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38658088

RESUMEN

Fluoride (F-) export proteins, including F- channels and F- transporters, are widespread in biology. They contribute to cellular resistance against fluoride ion, which has relevance as an ancient xenobiotic, and in more modern contexts like organofluorine biosynthesis and degradation or dental medicine. This chapter summarizes quantitative methods to measure fluoride transport across membranes using fluoride-specific lanthanum-fluoride electrodes. Electrode-based measurements can be used to measure unitary fluoride transport rates by membrane proteins that have been purified and reconstituted into lipid vesicles, or to monitor fluoride efflux into living microbial cells. Thus, fluoride electrode-based measurements yield quantitative mechanistic insight into one of the major determinants of fluoride resistance in microorganisms, fungi, yeasts, and plants.


Asunto(s)
Fluoruros , Lantano , Fluoruros/química , Fluoruros/metabolismo , Lantano/química , Lantano/metabolismo , Electrodos , Transporte Biológico , Electrodos de Iones Selectos
9.
J AOAC Int ; 107(1): 103-111, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-37698980

RESUMEN

BACKGROUND: The AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals issued a call for methods for the determination of fluoride in infant formula. Standard Method Performance Requirement (SMPR®) 2014.016 was approved. OBJECTIVE: A single-laboratory validation (SLV) of a fluoride ion-selective electrode (F-ISE) method was completed. METHODS: Five powder samples were reconstituted, and hydrochloric acid was added to dissolve and release any bound fluoride. Samples included infant and adult nutritional products made from milk, whey, or soy, containing intact, partially hydrolyzed, or hydrolyzed proteins. Sodium citrate buffer was added to complex any interfering ions and adjust pH and ionic strength. Samples were analyzed in duplicate over 6 days using F-ISE. RESULTS: Results were calculated based on one of two least-squares (log fit) standard curves (0.02 to 0.1 µg/100 g or 0.1 to 2.0 µg/100 g). The LOQ for the method was determined to be 3.3 µg/100 g, which was far below the minimum analytical value of 30 µg/100 g required in the SMPR. The fluoride concentrations ranged from approximately 3 to 14 µg/100 g reconstituted powder and the intermediate precision, RSDr, ranged from 0.7 to 12.4%. Although all of these results are out of scope for the SMPR due to their low fluoride, it should be noted that the RSDr for formulas with fluoride concentrations ranging from approximately 9 to 14 µg/100 g ranged from 0.7 to 4.3%, and the RSDr for the two formulas with fluoride concentrations at or below the theoretical detection limit of the method were only approximately10 and 12.4%. Recoveries ranged from 94 to 98% for samples spiked at three levels with NIST-traceable standard solutions, meeting the SMPR. CONCLUSION: The F-ISE method meets the SMPR and was adopted as a First Action Official MethodSM. HIGHLIGHTS: The fluoride ion-selective electrode method presented here is affordable and easy to run. The addition of acid to the samples dissolves any minerals which may bind the fluoride.


Asunto(s)
Leche , Leche de Soja , Humanos , Lactante , Adulto , Animales , Fluoruros , Agua , Polvos , Electrodos de Iones Selectos , Fórmulas Infantiles , Alimentos Formulados
10.
Environ Sci Technol ; 58(2): 1359-1368, 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38079615

RESUMEN

Lithium holds immense significance in propelling sustainable energy and environmental systems forward. However, existing sensors used for lithium monitoring encounter issues concerning their selectivity and long-term durability. Addressing these challenges is crucial to ensure accurate and reliable lithium measurements during the lithium recovery processes. In response to these concerns, this study proposes a novel approach involving the use of an MXene composite membrane with incorporated poly(sodium 4-styrenesulfonate) (PSS) as an antibiofouling layer on the Li+ ion selective electrode (ISE) sensors. The resulting MXene-PSS Li+ ISE sensor demonstrates exceptional electrochemical performance, showcasing a superior slope (59.42 mV/dec), lower detection limit (10-7.2 M), quicker response time (∼10 s), higher selectivity to Na+ (-2.37) and K+ (-2.54), and reduced impedance (106.9 kΩ) when compared to conventional Li+ ISE sensors. These improvements are attributed to the unique electronic conductivity and layered structure of the MXene-PSS nanosheet coating layer. In addition, the study exhibits the long-term accuracy and durability of the MXene-PSS Li+ ISE sensor by subjecting it to real wastewater testing for 14 days, resulting in sensor reading errors of less than 10% when compared to laboratory validation results. This research highlights the great potential of MXene nanosheet coatings in advancing sensor technology, particularly in challenging applications, such as detecting emerging contaminants and developing implantable biosensors. The findings offer promising prospects for future advancements in sensor technology, particularly in the context of sustainable energy and environmental monitoring.


Asunto(s)
Electrodos de Iones Selectos , Litio , Nitritos , Elementos de Transición , Impedancia Eléctrica , Electrónica
11.
ACS Sens ; 9(1): 415-423, 2024 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-38154098

RESUMEN

The high selectivity and fast ion response of all-solid sodium ion selective electrodes were widely applied in human sweat analysis. However, the potential drift due to insufficient interfacial capacitance leads to the deterioration of its stability and ultimately affects the potential accuracy of ion analysis. Designing a novel ion-electron transduction layer between the electrode and the ion selective membrane is an effective method to stabilize the interfacial potential. Herein, the SnS2-MoS2 heterojunction material was constructed by doping Sn in MoS2 nanosheets and used as the ion electron transduction layers of an all-solid sodium ion selective electrode for the first time, achieving the stable and efficient detection of Na+ ions. The proposed electrode exhibited a Nernst slope of 57.86 mV/dec for the detection of Na+ ions with a detection limit of 10-5.7 M in the activity range of 10-6-10-1 M. Via the electronic interaction at the heterojunction interfaces between SnS2 and MoS2 materials, the micro-nanostructure of the SnS2-MoS2 heterojunction was changed and SnS2-MoS2 as the ion-electron transduction layer acquired excellent capacitance (699 µF) and hydrophobicity (132°), resulting in a long-term potential stability of 1.37 µV/h. It was further proved that the large capacitance and high hydrophobicity of the ion-electron transduction layer are primary reasons for the excellent stability of the all-solid sodium ion selective electrode toward Na+ ions.


Asunto(s)
Electrodos de Iones Selectos , Molibdeno , Humanos , Electrones , Capacidad Eléctrica , Iones
12.
Biosens Bioelectron ; 248: 115971, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38154328

RESUMEN

Apomorphine is a dopamine agonist that is used for the management of Parkinson's disease and has been proven to effectively decrease the off-time duration, where the symptoms recur, in Parkinson's disease patients. This paper describes the design and fabrication of the first potentiometric sensor for the determination of apomorphine in bulk and human plasma samples. The fabrication protocol involves stereolithographic 3D printing, which is a unique tool for the rapid fabrication of low-cost sensors. The solid-contact apomorphine ion-selective electrode combines a carbon-mesh/thermoplastic composite as the ion-to-electron transducer and a 3D printed ion-selective membrane, doped with the ionophore calix[6]arene. The sensor selectively measures apomorphine in the presence of other biologically present cations - sodium, potassium, magnesium, and calcium - as well as the commonly prescribed Parkinson's pharmaceutical, levodopa (L-Dopa). The sensor demonstrated a linear, Nernstian response, with a slope of 58.8 mV/decade over the range of 5.0 mM-9.8 µM, which covers the biologically (and pharmaceutically) relevant ranges, with a limit of detection of 2.51 µM. Moreover, the apomorphine sensor exhibited good stability (minimal drift of just 188 µV/hour over 10 h) and a shelf-life of almost 4 weeks. Experiments performed in the presence of albumin, the main plasma protein to which apomorphine binds, demonstrate that the sensor responds selectively to free-apomorphine (i.e., not bound or complexed forms). The utility of the sensor was confirmed through the successful determination of apomorphine in spiked human plasma samples.


Asunto(s)
Técnicas Biosensibles , Enfermedad de Parkinson , Humanos , Apomorfina , Enfermedad de Parkinson/tratamiento farmacológico , Electrodos de Iones Selectos , Preparaciones Farmacéuticas , Potenciometría
13.
Int J Mol Sci ; 24(24)2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38139093

RESUMEN

The multifunctionality of an A3B mixed-substituted porphyrin, namely 5-(4-carboxyphenyl)-10,15,20-tris(4-methylphenyl)porphyrin (5-COOH-3MPP), was proven due to its capacity to detect procaine by different methods, depending on the polymer matrix in which it is incorporated. The hybrid nanomaterial containing k-carrageenan and AuNPs (5-COOH-3MPP-k-carrageenan-AuNPs) was able to optically detect procaine in the concentration range from 5.76 × 10-6 M to 2.75 × 10-7 M, with a limit of detection (LOD) of 1.33 × 10-7 M. This method for the detection of procaine gave complementary results to the potentiometric one, which uses 5-COOH-3MPP as an electroactive material incorporated in a polyvinylchloride (PVC) membrane plasticized with o-NPOE. The detected concentration range by this ion-selective membrane electrode is wider (enlarged in the field of higher concentrations from 10-2 to 10-6 M), linearly dependent with a 53.88 mV/decade slope, possesses a detection limit of 7 × 10-7 M, a response time of 60 s, and has a certified stability for a working period of six weeks.


Asunto(s)
Nanopartículas del Metal , Porfirinas , Procaína , Carragenina , Oro , Electrodos de Iones Selectos
14.
Sci Rep ; 13(1): 20187, 2023 11 18.
Artículo en Inglés | MEDLINE | ID: mdl-37980444

RESUMEN

Analysis of drugs clinically and their identification in biological samples are of utmost importance in the process of therapeutic drug monitoring, also in pharmacokinetic investigations and tracking of illicit medications. These investigations are carried out using a variety of analytical methods, including potentiometric electrodes. Potentiometric electrodes are a wonderful solution for researchers because they outperform other methods in terms of sustainability, greenness, and cost effectiveness. In the current study, ion-selective potentiometric sensors were assembled for the aim of quantification of the anticancer drug Letrozole (LTZ). The first step was fabrication of a conventional sensor based on the formation of stable host-guest inclusion complex between the cationic drug and 4-tert-butylcalix-8-arene (TBCAX-8). Two additional sensors were prepared through membrane modification with graphene nanocomposite (GNC) and polyaniline (PANI) nanoparticles. Linear responses of 1.00 × 10-5-1.00 × 10-2, 1.00 × 10-6-1.00 × 10-2 and 1.00 × 10-8-1.00 × 10-3 with sub-Nernstian slopes of 19.90, 20.10 and 20.30 mV/decade were obtained for TBCAX-8, GNC, and PANI sensors; respectively. The developed sensors were successful in determining the drug LTZ in bulk powder and dosage form. PANI modified sensor was used to determine LTZ in human plasma with recoveries ranging from 88.00 to 96.30%. IUPAC recommendations were followed during the evaluation of the electrical performance of the developed sensors. Experimental conditions as temperature and pH were studied and optimized. Analytical Eco-scale and Analytical GREEness metric were adopted as the method greenness assessment tools.


Asunto(s)
Grafito , Electrodos de Iones Selectos , Humanos , Letrozol , Electrodos , Potenciometría/métodos
15.
Biosensors (Basel) ; 13(10)2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37887107

RESUMEN

Free-floating electrochemical sensors are promising for in situ bioprocess monitoring with the advantages of movability, a lowered risk of contamination, and a simplified structure of the bioreactor. Although floating sensors were developed for the measurement of physical and chemical indicators such as temperature, velocity of flow, pH, and dissolved oxygen, it is the lack of available electrochemical sensors for the determination of the inorganic ions in bioreactors that has a significant influence on cell culture. In this study, a capsule-shaped electrochemical system (iCapsuleEC) is developed to monitor ions including K+, NH4+, Na+, Ca2+, and Mg2+ based on solid-contact ion-selective electrodes (SC-ISEs). It consists of a disposable electrochemical sensor and signal-processing device with features including multichannel measurement, self-calibration, and wireless data transmission. The capacities of the iCapsuleEC were demonstrated not only for in situ measurement of ion concentrations but also for the optimization of the sensing electrodes. We also explored the possibility of the system for use in detection in simulated cell culture media.


Asunto(s)
Reactores Biológicos , Electrodos de Iones Selectos , Iones , Calibración , Técnicas de Cultivo de Célula
16.
ACS Sens ; 8(11): 4198-4206, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-37773015

RESUMEN

The high-temperature potentiometry operated by nonisothermal heating is a promising way to break through the traditional potentiometric responses of ion-selective electrodes (ISEs) at room temperature. Herein, a locally heated strategy through near-infrared region (NIR) laser irradiation upon the photothermal mesoporous carbon material placed between the ion-selective membrane and the glassy carbon substrate is introduced to obtain the high-temperature potentiometric performance of a solid-contact Ca2+-ISE for detection of Ca2+ in seawater. Based on the light-to-heat conversion of the mesoporous carbon-based solid contact, the temperature of the solid-contact Ca2+-ISE upon continuous NIR laser irradiation can be increased from room temperature to 60-70 °C, and the slope of the electrode is promoted up to about 30% according to the thermodynamic steady-state potentiometric response. The pulsed potentiometric response of the solid-contact Ca2+-ISE upon a pulsed NIR laser irradiation of 5 s also shows a linear change as a function of Ca2+ activities, and the improved slope from 27.1 ± 0.6 to 38.1 ± 0.9 mV/dec can be obtained under dual control of the temperature of the electrode and the transient current induced by the pulsed NIR laser irradiation. As compared to the traditional potentiometric measurement under zero-current conditions at room temperature, the NIR laser-modulated high-temperature potentiometric response provides an alternative way for measurement of the solid-contact ISEs.


Asunto(s)
Carbono , Electrodos de Iones Selectos , Potenciometría , Temperatura , Agua de Mar , Rayos Infrarrojos
17.
Anal Chim Acta ; 1278: 341707, 2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37709450

RESUMEN

BACKGROUND: An anti-H-pylori co-formulated mixture of tetracycline HCl (TET), metronidazole (MET), and bismuth subcitrate (BSC) is recently available. Only two chromatographic and spectrophotometric methods are reported for determining those drugs simultaneously where the effect of impurities that could be present as well as the biological fluids matrix influence do not be taken into consideration. There is a need to develop an easy-to-use potentiometric technique for analysis of TET, MET, and BSC in their co-formulated capsules, in presence of some official impurities and in spiked human plasma. RESULTS: Three carbon paste electrodes (CPEs) were fabricated for this purpose. Being a solid contact ion-selective electrode, CPE suffers from the creation of a water layer affecting its stability and reproducibility. Besides, it has a common problem in differentiation between two drugs carrying the same charge (positively charged TET and MET). Water layer formation was prevented through inserting polyaniline nanoparticles (≈10.0 nm diameter) between solid contact and ion-sensing membrane in the three proposed sensors. TET and MET interference was overcome by synthesizing a corresponding molecular imprinted polymer (MIP) for each drug. The synthesized MIPs were inserted in equivalent sensing membranes and characterized using several techniques. The suggested MIPs have a noticeable enhanced sensitivity in potentiometric determination. The obtained LODs were 5.88 × 10-8, 5.19 × 10-7, and 1.73 × 10-6 M for TET, MET and BSC proposed CPEs, respectively, with corresponding slopes of 57.37, 56.20, and -57.40 mV decade-1. SIGNIFICANCE: The proposed potentiometric method makes the detection of the three cited drugs simple, fast, and feasible. This approach is the first for determining three drugs potentiometrically in one combined formulation. The obtained results were compared favorably with previously reported potentiometric methods.


Asunto(s)
Carbono , Metronidazol , Humanos , Cápsulas , Reproducibilidad de los Resultados , Electrodos de Iones Selectos , Tetraciclinas
18.
Anal Chem ; 95(33): 12557-12564, 2023 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-37567148

RESUMEN

The self-monitoring of electrolytes using a small volume of capillary blood is needed for the management of many chronic diseases. Herein, we report an ionophore-based colorimetric sensor for electrolyte measurements in a few microliters of blood. The sensor is a pipet microtip preloaded with a segment of oil (plasticizer) containing a pH-sensitive chromoionophore, a cation exchanger, and an ionophore. The analyte is extracted from the sample into the oil via a mixing protocol controlled by a stepper motor. The oil with an optimized ratio of sensing chemicals shows an unprecedentedly large color response for electrolytes in a very narrow concentration range that is clinically relevant. This ultrahigh sensitivity is based on an exhaustive response mode with a novel mechanism for defining the lower and higher limits of detection. Compared to previous optodes and molecular probes for ions, the proposed platform is especially suitable for at-home blood electrolyte measurements because (1) the oil sensor is interrogated independent of the sample and therefore works for whole blood without requiring plasma separation; (2) the sensor does not need individual calibration as the consistency between liquid sensors is high compared to solid sensors, such as ion-selective electrodes and optodes; and (3) the sensing system consisting of a disposable oil sensor, a programmed stepper motor, and a smartphone is portable, cost-effective, and user-friendly. The accuracy and precision of Ca2+ sensors are validated in 51 blood samples with varying concentrations of total plasma Ca2+. Oil sensors with an ultrasensitive response can also be obtained for other ions, such as K+.


Asunto(s)
Colorimetría , Electrodos de Iones Selectos , Ionóforos/química , Cationes
19.
Anal Chem ; 95(33): 12419-12426, 2023 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-37552138

RESUMEN

Solid-contact ion-selective electrodes (SC-ISEs) in direct long-term contact with physiological samples must be biocompatible and resistant to biofouling, but most wearable SC-ISEs proposed to date contain plasticized poly(vinyl chloride) (PVC) membranes, which have poor biocompatibility. Silicones are a promising alternative to plasticized PVC because of their excellent biocompatibility, but little work has been done to study the relationship between silicone composition and ISE performance. To address this, we prepared and tested K+ SC-ISEs with colloid-imprinted mesoporous (CIM) carbon as the solid contact and three different condensation-cured silicones: a custom silicone prepared in-house (Silicone 1), a commercial silicone (Dow 3140, Silicone 2), and a commercial fluorosilicone (Dow 730, Fluorosilicone 1). SC-ISEs prepared with each of these polymers and the ionophore valinomycin and added ionic sites exhibited Nernstian responses, excellent selectivities, and signal drifts as low as 3 µV/h in 1 mM KCl solution. All ISEs maintained Nernstian response slopes and had only very slightly worsened selectivities after 41 h exposure to porcine plasma (log KK,Na values of -4.56, -4.58, and -4.49, to -4.04, -4.00, and -3.90 for Silicone 1, Silicone 2, and Fluorosilicone 1, respectively), confirming that these sensors retain the high selectivity that makes them suitable for use in physiological samples. When immersed in porcine plasma, the SC-ISEs exhibited emf drifts that were still fairly low but notably larger than when measurements were performed in pure water. Interestingly, despite the very similar structures of these matrix polymers, SC-ISEs prepared with Silicone 2 showed lower drift in porcine blood plasma (-55 µV/h, over 41 h) compared to Silicone 1 (-495 µV/h) or Fluorosilicone 1 (-297 µV/h).


Asunto(s)
Plastificantes , Siliconas , Animales , Porcinos , Electrodos de Iones Selectos , Agua , Polímeros , Iones/química
20.
Sensors (Basel) ; 23(13)2023 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-37447689

RESUMEN

Potentiometric sensors are the largest and most commonly used group of electrochemical sensors. Among them, ion-selective electrodes hold a prominent place. Since the end of the last century, their re-development has been observed, which is a consequence of the introduction of solid contact constructions, i.e., electrodes without an internal electrolyte solution. Research carried out in the field of potentiometric sensors primarily focuses on developing new variants of solid contact in order to obtain devices with better analytical parameters, and at the same time cheaper and easier to use, which has been made possible thanks to the achievements of material engineering. This paper presents an overview of new materials used as a solid contact in ion-selective electrodes over the past several years. These are primarily composite and hybrid materials that are a combination of carbon nanomaterials and polymers, as well as those obtained from carbon and polymer nanomaterials in combination with others, such as metal nanoparticles, metal oxides, ionic liquids and many others. Composite materials often have better mechanical, thermal, electrical, optical and chemical properties than the original components. With regard to their use in the construction of ion-selective electrodes, it is particularly important to increase the capacitance and surface area of the material, which makes them more effective in the process of charge transfer between the polymer membrane and the substrate material. This allows to obtain sensors with better analytical and operational parameters. Brief characteristics of electrodes with solid contact, their advantages and disadvantages, as well as research methods used to assess their parameters and analytical usefulness were presented. The work was divided into chapters according to the type of composite material, while the data in the table were arranged according to the type of ion. Selected basic analytical parameters of the obtained electrodes have been collected and summarized in order to better illustrate and compare the achievements that have been described till now in this field of analytical chemistry, which is potentiometry. This comprehensive review is a compendium of knowledge in the research area of functional composite materials and state-of-the-art SC-ISE construction technologies.


Asunto(s)
Electrodos de Iones Selectos , Polímeros , Electrodos , Polímeros/química , Óxidos , Potenciometría , Carbono/química