RESUMEN
Thoracic endovascular aortic repair is commonly used in the surgical treatment of patients with aortic coarctation, but complications such as endoleaks can occur. This video tutorial presents a case study involving the exclusion of a stent graft from the bloodstream through total transection of the aortic arch and abdominal aorta, with off-pump aortic grafting and debranching of the left carotid and subclavian arteries.
Asunto(s)
Implantación de Prótesis Vascular , Endofuga , Procedimientos Endovasculares , Humanos , Endofuga/etiología , Endofuga/cirugía , Endofuga/diagnóstico , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/efectos adversos , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/efectos adversos , Masculino , Aorta Abdominal/cirugía , Stents , Aorta Torácica/cirugía , Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnósticoRESUMEN
CASE: We present a case of a 66-year-old man with lumbar vertebral body erosions after glue embolization of a Type II endoleak secondary to endovascular repair of an infrarenal aortic aneurysm. Multiple biopsies of the affected vertebrae were culture-negative confirming no evidence of infection. He underwent posterior spinal fusion from L2 to L5 with complete resolution of mechanical low back pain and improved functional outcomes. CONCLUSION: Vertebral body osseous erosion is a rare complication of aortic endoleak intervention that can be successfully treated with spinal fusion.
Asunto(s)
Embolización Terapéutica , Endofuga , Humanos , Masculino , Anciano , Endofuga/etiología , Endofuga/diagnóstico por imagen , Endofuga/terapia , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Cuerpo Vertebral/diagnóstico por imagen , Cuerpo Vertebral/cirugía , Procedimientos Endovasculares/efectos adversos , Vértebras Lumbares/cirugía , Fusión Vertebral/efectos adversos , Fusión Vertebral/instrumentaciónRESUMEN
OBJECTIVE: To evaluate the mid-term outcomes of different treatment strategies for the internal iliac artery (IIA) during EVAR. METHODS: This was a retrospective study. All patients undergoing EVAR, who required treatment of at least one side of IIA from January 2013 to July 2022 in a single center, were included. According to the different treatment strategies for IIA, the patients were divided into UP (unilateral preservation), BP (bilateral preservation) and BE (bilateral embolization) groups. The primary outcomes included buttock claudication, bowel ischemia and iliac-related reintervention. Then patients who underwent IIA reconstruction were divided into IPG (iliac parallel stent graft) and IBG (iliac branch stent graft) groups according to the reconstruction technique. The primary outcomes included endoleak, iliac branch occlusion and iliac-related reintervention. RESULTS: A total of 237 patients were included, including 167 in the UP group, 9 in the BP group and 61 in the BE group. The mean follow-up time was 39.0 ± 27.7, 50.0 ± 22.1 and 25.8 ± 18.9 months in UP, BP and BE groups, respectively. Thirty cases (12.7%) of buttock claudication occurred, and it was significantly higher in the BE group than the UP group (26.2% vs. 7.8%, p < 0.001). There were no significant differences in the other follow-up outcomes among three groups. The K-M analysis indicated that the patients in the BE group had a lower survival rate than those in the other two groups (p = 0.024). 24 patients underwent IIA reconstruction, including 8 in the IPG group and 16 in the IBG group. The endoleak in the IBG group was significantly lower than that in the IPG group (0% vs. 25.0%, p = 0.041). The iliac-related reintervention, iliac occlusion and mortality were similar between the two groups. CONCLUSION: Overall it is beneficial for patients to preserve at least one side of IIA during EVAR as much as possible. Compared with IPG, IBG might be more applicable for IIA reconstruction.
Asunto(s)
Procedimientos Endovasculares , Arteria Ilíaca , Humanos , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/efectos adversos , Masculino , Femenino , Anciano , Arteria Ilíaca/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Stents , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma Ilíaco/cirugía , Endofuga/cirugía , Endofuga/etiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Embolización Terapéutica/métodos , Reparación Endovascular de AneurismasRESUMEN
INTRODUCTION: Aneurysmal sac regression is a predictor of long-term outcomes after endovascular aneurysm repair (EVAR). This study aimed to compare a large cohort of TREO and non-TREO endografts over a mid-term follow-up and compare abdominal aortic aneurysm sac regression. The hypothesis was that TREO endografts have an increased sac regression by 24 mo. METHODS: This is a retrospective analysis of all EVARs completed at a single institution between 2015 and 2024. Clinical and imaging data were collected from an institutional database and patients' records. The analysis included all TREO and age, sex, anticoagulation use and current smoking-matched non-TREO endografts that satisfied anatomic indications for use of the TREO graft. The primary outcomes were sac regression at 12 and 24 mo, and secondary outcomes were rates of mortality, endoleak, and reintervention. RESULTS: Twenty-one TREO grafts were matched to 68 non-TREO grafts. The groups were similar in demographics, comorbidities, and preoperative anatomy. Preoperative abdominal aortic aneurysm sac size was larger in the TREO cohort. The mean reduction in sac size in mm was greater in the TREO cohort compared to the non-TREO cohort (-12.6 ± 8.95 versus -7.83 ± 7.74 mm, P = 0.039) over the study period. Cox regression analysis identified the TREO stent graft to be associated with 1-y sac regression (hazard ratio = 2.42, P = 0.019). The incidence of all-cause endoleaks, reintervention, and mortality were similar between cohorts. CONCLUSIONS: These findings suggest that the TREO endograft offers better mid-term outcomes with respect to sac regression with no differences in the incidence of endoleak, mortality, or reintervention.
Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Femenino , Estudios Retrospectivos , Aneurisma de la Aorta Abdominal/cirugía , Anciano , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Estudios de Seguimiento , Anciano de 80 o más Años , Resultado del Tratamiento , Endofuga/etiología , Endofuga/epidemiología , Persona de Mediana Edad , Stents/efectos adversos , Diseño de PrótesisAsunto(s)
Aprendizaje Profundo , Endofuga , Procedimientos Endovasculares , Tomografía Computarizada por Rayos X , Humanos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Procedimientos Endovasculares/métodos , Tomografía Computarizada por Rayos X/métodos , Implantación de Prótesis Vascular/métodos , Reparación Endovascular de AneurismasRESUMEN
BACKGROUND: Metallic and hyperdense artifacts and T1-shortening substances in the abdominal aortic aneurysm (AAA) sac generated by embolic materials and lipiodol pose challenges in the identification of endoleaks on follow-up computed tomography (CT) or magnetic resonance imaging (MRI). PURPOSE: To evaluate the usefulness of contrast-enhanced subtraction MRI (CES-MRI) for detecting endoleaks after endovascular abdominal aortic aneurysm repair (EVAR) with intraoperative AAA sac embolization compared with CE-CT, this study was conducted. MATERIAL AND METHODS: In this study, 28 consecutive patients who underwent EVAR with prophylactic AAA sac embolization were included. All patients underwent CES-MRI and CE-CT to detect endoleaks. The definitive diagnosis of endoleaks was a consensus reading of CE-CT and CES-MRI by two certified radiologists, in addition to angiography or reproducible radiological findings in the observational examination. Analysis was performed to evaluate which examination was better for detecting endoleaks. RESULTS: The sensitivity, specificity, and area under the curve of CE-CT and CES-MRI according to observer 1 were 50%, 100%, and 0.813 (95% confidence interval [CI] = 0.625-1.00) and 100%, 95%, and 0.997 (95% CI = 0.984-1.00), respectively, and those according to observer 2 were 50%, 100%, and 0.750 (95% CI = 0.514-0.986) and 100%, 95%, and 0.969 (95% CI = 0.903-1.00), respectively. Intolerable artifacts were significantly observed on CE-CT. The severity of the artifacts did not depend on the stent graft on CT and MRI. CONCLUSION: Although no significant difference was observed, CES-MRI tended to have better accuracy for endoleak detection in EVAR with intraoperative AAA sac embolization than CE-CT.
Asunto(s)
Aneurisma de la Aorta Abdominal , Medios de Contraste , Embolización Terapéutica , Endofuga , Procedimientos Endovasculares , Imagen por Resonancia Magnética , Humanos , Endofuga/diagnóstico por imagen , Masculino , Femenino , Anciano , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Procedimientos Endovasculares/métodos , Embolización Terapéutica/métodos , Imagen por Resonancia Magnética/métodos , Anciano de 80 o más Años , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Técnica de Sustracción , Estudios Retrospectivos , Persona de Mediana Edad , Reparación Endovascular de AneurismasRESUMEN
BACKGROUND: We analyzed the long-term influence of fixation systems on proximal aortic neck (PAN) evolution by comparing 2 late-generation endoprostheses, Endurant (Medtronic Vascular, Minneapolis, Minn) with suprarenal fixation (SRF) and Excluder (W.L Gore & Associates, Flagstaff, Ariz) with infrarenal fixation (IRF). METHODS: Our retrospective observational study included consecutive patients undergoing endovascular aneurysm repair (EVAR) for aorto-iliac aneurysms (2011-2020). Primary end points: neck enlargement and freedom from significative PAN enlargement (5 mm). Secondary end points: neck-related reintervention, endoleaks and graft migration. Results were reported following the Society of Vascular Surgery reporting standards. RESULTS: 139 patients were included (97 in SRF group and 42 in IRF group). A difference in growth at 10 mm caudal to lowest renal artery at 2 years follow-up was found (mean growth of 1.92 ± 3.38 mm in SRF and 0.16 ± 6.86 mm in IRF; P < 0.001). A tendency to a major growth in SRF at 4 years follow-up at the lowest renal artery (1.27 ± 3.36 mm vs. 0.63 ± 2.2 mm; P = 0.06), 5 mm distal to lowest renal artery (2.17 ± 3.52 mm vs. 0.94 ± 2.76 mm; P = 0.001) and 10 mm distal to lowest renal artery (2.65 ± 3.86 mm vs. 1.12 ± 1.5 mm; P < 0.001) was shown. Freedom from PAN enlargement was 96.65% and 88.20% in SRF and 100% and 94.4% in IRF at 2 and 4 years follow-up respectively (log rank 0.041). A greater incidence of type II endoleaks in IRF was observed (40.48% vs. 15.46%; P = 0.001). Oversizing >15% showed to be a risk factor of PAN enlargement (odds ratio 6.85; 95% confident interval: 1.67-28.4; P = 0.007). CONCLUSIONS: A small but significative percentage of patients after EVAR show a progressive PAN enlargement, being significatively greater in SRF, without increasing neck-related complications 4 years after graft deployment.
Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Diseño de Prótesis , Humanos , Estudios Retrospectivos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Masculino , Femenino , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Anciano , Factores de Tiempo , Factores de Riesgo , Anciano de 80 o más Años , Endofuga/etiología , Endofuga/diagnóstico por imagen , Resultado del Tratamiento , Stents , Aneurisma Ilíaco/cirugía , Aneurisma Ilíaco/diagnóstico por imagen , Persona de Mediana Edad , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/cirugíaRESUMEN
PURPOSE: To compare the safety and effectiveness of n-butyl cyanoacrylate (nBCA)-ethiodized oil (NE) mixture and nBCA-ethiodized oil-ethanol (NEE) mixture embolization for Type II endoleak (T2EL) after endovascular aortic repair. MATERIALS AND METHODS: This study included 32 patients with 49 procedures who underwent T2EL embolization between January 2008 and June 2022. Cases with no follow-up after embolization, technical failure, treatment with coil only, Type I endoleak at the embolization, and re-embolization were excluded. The resultant final cohort included 24 patients (14 men and 10 women; mean age, 83.3 years [interquartile range, 77-89 years]) who underwent initial T2EL embolization, with 15 patients in the NE group and 9 patients in the NEE group. The 2 groups were compared in terms of adverse events (AEs), freedom from sac enlargement, and freedom from reintervention. RESULTS: The follow-up period after embolization for T2EL was 960 days (SD ± 1,007) in the NE group and 484 days (SD ± 192) in the NEE group, without significant differences. No AEs above moderate were observed in either group. The rate of freedom from sac enlargement at 1 year was 65.0% in the NE group and 87.5% in the NEE group (P = .03). The rate of freedom from reintervention at 1 year was 69.2% in the NE group and 100.0% in the NEE group (P = .02). CONCLUSIONS: The NEE group had significantly higher rates of freedom from sac enlargement and reintervention at 1 year compared with the NE group. These results suggest that T2EL embolization with NEE may be more effective than that with NE.
Asunto(s)
Embolización Terapéutica , Enbucrilato , Endofuga , Procedimientos Endovasculares , Etanol , Aceite Etiodizado , Humanos , Anciano , Embolización Terapéutica/efectos adversos , Masculino , Femenino , Endofuga/terapia , Endofuga/etiología , Endofuga/diagnóstico por imagen , Enbucrilato/administración & dosificación , Enbucrilato/efectos adversos , Anciano de 80 o más Años , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Estudios Retrospectivos , Aceite Etiodizado/administración & dosificación , Aceite Etiodizado/efectos adversos , Etanol/administración & dosificación , Etanol/efectos adversos , Factores de Tiempo , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Resultado del Tratamiento , Factores de Riesgo , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugíaRESUMEN
BACKGROUND: Our aim was to analyse abdominal aneurysm sac thrombus density and volume on computed tomography (CT) after endovascular aneurysm repair (EVAR). METHODS: Patients who underwent EVAR between January 2005 and December 2010 and had at least four follow-up CT exams available over the first five years of follow-up were included in this retrospective single-centre study. Thrombus density and aneurysm sac volume were calculated on unenhanced CT scans. Linear mixed models were used for data analysis. RESULTS: Out of 82 patients, 44 (54%) had an endoleak on post-EVAR contrast-enhanced CT. Thrombus density significantly increased over time in both the endoleak and non-endoleak groups, with a slope of 0.159 UH/month (95% confidence interval [CI] 0.115-0.202), p < 0.0001) and 0.052 UH/month (95% CI 0.002-0.102, p = 0.041). In patients without endoleak, a significant decrease in aneurysm sac volume was identified over time (slope -0.891 cc/month, 95% CI -1.200 to -0.581); p < 0.001) compared to patients with endoleak (slope 0.284 cc/month, 95% CI -0.031 to 0.523, p = 0.082). The association between thrombus density and aneurysm sac volume was positive in the endoleak group (slope 1.543 UH/cc, 95% CI 0.948-2.138, p < 0.001) and negative in the non-endoleak group (slope -1.450 UH/cc, 95% CI -2.326 to -0.574, p = 0.001). CONCLUSION: We observed a progressive increase in thrombus density of the aneurysm sac after EVAR in patients with and without endoleak, more pronounced in patients with endoleak. The association between aneurysm volume and thrombus density was positive in patients with and negative in those without endoleak. RELEVANCE STATEMENT: A progressive increase in thrombus density and volume of abdominal aortic aneurysm sac on unenhanced CT might suggest underlying endoleak lately after EVAR. KEY POINTS: Thrombus density of the aneurysm sac after EVAR increased over time. Progressive increase in thrombus density was significantly associated to the underlying endoleak. The association between aneurysm volume and thrombus density was positive in patients with and negative in those without endoleak.
Asunto(s)
Aneurisma de la Aorta Abdominal , Endofuga , Procedimientos Endovasculares , Trombosis , Tomografía Computarizada por Rayos X , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Endofuga/diagnóstico por imagen , Endofuga/etiología , Femenino , Masculino , Estudios Retrospectivos , Anciano , Procedimientos Endovasculares/métodos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Tomografía Computarizada por Rayos X/métodos , Anciano de 80 o más AñosRESUMEN
BACKGROUND: The unibody bifurcated aortic endograft (AFX/AFX2) has emerged as a treatment option for abdominal aortic aneurysms (AAAs). This systematic review and meta-analysis aimed to evaluate the safety of the unibody endograft. METHODS: A literature search was conducted in Cochrane Library, Scopus, Web of Science, and PubMed. Studies assessing the unibody endograft for AAA repair between 2014 and 2023 were included. The defined primary outcomes were the incidences of type I, II, and III endoleaks. The secondary outcomes were access site problems, aneurysm-related mortality, aneurysm rupture, all-cause mortality, aneurysm sac growth, limb occlusion, stent graft migration, and technical success rate. RESULTS: Fourteen studies including 12 observational studies and 2 randomized controlled trials were included in the systematic review. The meta-analysis included 10 studies with 12,690 patients that reported the measured outcomes, and excluded 4 studies that did not. Type II endoleaks had the highest incidence of 12% (95% confidence interval [CI]: 4-20%), followed by type III endoleaks with an incidence of 3% (95% CI: 1-5%). The incidence of type I endoleaks was 1% (95% CI: 0-2%). A subgroup analysis by follow-up duration showed that type II endoleak incidence was higher after 1 to 2 years of follow-up than 3 to 4 years of follow-up. The incidence of aneurysmal mortality was 2% (95% CI: 0-7%), limb occlusion was 1% (95% CI: 0-1%), stent graft migration was 1% (95% CI: 0-2%), aneurysmal rupture was 6% (95% CI: 2-11%), access site problems were 7% (95% CI: 2-13%), aneurysm sac growth was 2% (95% CI: 0-4%), all-cause mortality was 21% (95% CI: 4-38%), and technical success rate was 100% (95% CI: 98-100%). CONCLUSIONS: The unibody endograft is a safe and minimally invasive approach for AAA repair. However, potential complications necessitate close patient follow-up after the intervention.
Asunto(s)
Aneurisma de la Aorta Abdominal , Prótesis Vascular , Endofuga , Reparación Endovascular de Aneurismas , Diseño de Prótesis , Stents , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Prótesis Vascular/efectos adversos , Endofuga/epidemiología , Endofuga/etiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Medición de Riesgo , Factores de Riesgo , Stents/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Reparación Endovascular de Aneurismas/efectos adversos , Reparación Endovascular de Aneurismas/instrumentación , Reparación Endovascular de Aneurismas/mortalidadRESUMEN
BACKGROUND: The Global Iliac Branch Study (NCT05607277) is an international, multicenter, retrospective cohort study of anatomic predictors of adverse iliac events (AIEs) in aortoiliac aneurysms treated with iliac branch devices (IBDs). METHODS: Patients with pre-IBD and post-IBD computed tomography imaging were included. We measured arterial diameters, stenosis, calcification, bifurcation angles, and tortuosity indices using a standardized, validated protocol. A composite of ipsilateral AIE was defined, a priori, as occlusion, type I or III endoleak, device constriction, or clinical event requiring reintervention. Paired t-test compared tortuosity indices and splay angles pretreatment and post-treatment for all IBDs and by device material (stainless steel and nitinol). Two-sample t-test compared anatomical changes from pretreatment to post-treatment by device material. Logistic regression assessed associations between AIE and anatomic measurements. Analysis was performed by IBD. RESULTS: We analyzed 297 patients (286 males, 11 females) with 331 IBDs (227 stainless steel, 104 nitinol). Median clinical follow-up was 3.8 years. Iliac anatomy was significantly straightened with all IBD treatment, though stainless steel IBDs had a greater reduction in total iliac artery tortuosity index and aortic splay angle compared to nitinol IBDs (absolute reduction -0.20 [-0.22 to -0.18] vs. -0.09 [-0.12 to -0.06], P < 0.0001 and -19.6° [-22.4° to -16.9°] vs. -11.2° [-15.3° to -7.0°], P = 0.001, respectively). There were 54 AIEs in 44 IBDs in 42 patients (AIE in 13.3% of IBD systems), requiring 35 reinterventions (median time to event 41 days; median time to reintervention 153 days). There were 18 endoleaks, 29 occlusions, and 5 device constrictions. There were no strong associations between anatomic measurements and AIE overall, though internal iliac diameter was inversely associated with AIE in nitinol devices (nAIE, nitinol = 8). CONCLUSIONS: Purpose-built IBDs effectively treat aortoiliac disease, including that with tortuous anatomy, with a high patency rate (91.5%) and low reintervention rate (9.1%) at 4 years. Anatomic predictors of AIE are limited.
Asunto(s)
Aleaciones , Implantación de Prótesis Vascular , Prótesis Vascular , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares , Aneurisma Ilíaco , Valor Predictivo de las Pruebas , Diseño de Prótesis , Stents , Humanos , Femenino , Masculino , Aneurisma Ilíaco/diagnóstico por imagen , Aneurisma Ilíaco/cirugía , Aneurisma Ilíaco/fisiopatología , Estudios Retrospectivos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Anciano , Resultado del Tratamiento , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Factores de Tiempo , Factores de Riesgo , Anciano de 80 o más Años , Persona de Mediana Edad , Aortografía , Acero Inoxidable , Endofuga/etiología , Endofuga/diagnóstico por imagen , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/fisiopatología , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Arteria Ilíaca/cirugía , Estados UnidosRESUMEN
INTRODUCTION: Type II endoleaks (T2ELs) following endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA) can lead to aneurysm growth, compromising the stent graft seal and risking rupture. Preventing these endoleaks during EVAR involves filling the AAA sac around the stent graft to exclude the aneurysm and block any arteries causing the endoleak. This study investigates the feasibility and safety of using AneuFix, a biocompatible injectable polymer developed by TripleMed (Geleen, the Netherlands), for aneurysmal sac filling during EVAR in high-risk T2EL patients. METHODS AND ANALYSIS: A feasibility, single-arm, single-centre clinical trial will initially include five patients with infrarenal AAA, eligible for EVAR, and at high risk for T2EL based on the number of patent lumbar arteries and the cross-sectional area of the aortic lumen at the level of the inferior mesenteric artery. Postevaluation by the Data Safety and Monitoring Board, the study cohort will extend to 25 patients. During EVAR and after stent graft deployment, the aneurysm sac is filled with AneuFix polymer using a filling sheath positioned parallel to the contralateral limb with the tip inside the aneurysm sac. Primary outcome is technical success (successful AAA sac filling). The secondary outcomes include clinical success at 6 and 12 months (occurrence of T2ELs and AAA growth assessed with CT angiography), intraoperative and perioperative complications, all endoleaks, adverse events, re-interventions, aneurysm rupture and patient survival. ETHICS AND DISSEMINATION: This trial was approved by the Dutch Authorities (Central Committee on Research Involving Human Subjects, IGJ), Amsterdam University Medical Centre Ethical Commission, and adheres to the Declaration of Helsinki and European Medical Device Regulation. Results will be shared at (inter)national conferences and in peer-reviewed journals. TRIAL REGISTRATION NUMBER: NCT04307992.
Asunto(s)
Aneurisma de la Aorta Abdominal , Endofuga , Procedimientos Endovasculares , Estudios de Factibilidad , Polímeros , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Endovasculares/métodos , Endofuga/prevención & control , Implantación de Prótesis Vascular/métodos , Stents , Prótesis Vascular , Masculino , Femenino , Países Bajos , Reparación Endovascular de AneurismasRESUMEN
BACKGROUND: The occurrence of type II endoleaks after endovascular repair of aortic aneurysm has gradually gained increasing attention. We present a case of a patient with an expanding aneurysm after thoracic endovascular aortic repair (TEVAR) for a type II endoleak, in which successful direct ligations of the intercostal artery were performed using a sac incision without cardiopulmonary bypass (CPB) or graft replacement. CASE PRESENTATION: A 62-year-old male patient, previously treated with TEVAR for a descending thoracic aortic aneurysm, presented with ongoing chest discomfort. Based on the diagnosis of a growing aneurysm and type II endoleak, the patient was prepared for CPB and aortic cross-clamping, as a precautions against the possibility of a type I endoleak. A longitudinal opening of the thoracic aortic aneurysm sac was performed following left thoracotomy. Visual confirmation identified the T5 level intercostal artery as the source of the endoleak, and after confirming the absence of a type I endoleak, multiple ligations were applied to the intercostal artery. Follow-up computed tomography confirmed the absence of endoleaks or sac growth. CONCLUSION: In a case involving TEVAR for a thoracic aortic aneurysm, open suture ligations were used to treat type II endoleaks without having to resort to CPB, resulting in successful outcomes.
Asunto(s)
Aneurisma de la Aorta Torácica , Endofuga , Procedimientos Endovasculares , Humanos , Masculino , Endofuga/cirugía , Endofuga/etiología , Persona de Mediana Edad , Aneurisma de la Aorta Torácica/cirugía , Procedimientos Endovasculares/métodos , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/efectos adversos , Tomografía Computarizada por Rayos X , Aorta Torácica/cirugía , Ligadura , Reparación Endovascular de AneurismasRESUMEN
AIM: This study aimed to investigate the utility of low-energy virtual monochromatic imaging (VMI) combined with deep-learning image reconstruction (DLIR) in improving the delineation of endoleaks (ELs) after endovascular aortic repair (EVAR) in contrast-enhanced dual-energy CT (DECT). METHODS: A total of 61 consecutive patients (mean age, 77 years; 46 men) after EVAR who underwent contrast-enhanced DECT were enrolled. Virtual monochromatic 40- and 70-keV images were reconstructed using DLIR (TrueFidelity-H) and conventional hybrid iterative reconstruction (IR). Contrast-to-noise ratio (CNR) of the EL on the venous-phase CT was calculated. Four different reconstructed image series (hybrid IR and DLIR at two energy levels, 40- and 70-keV) were displayed side-by-side and visually assessed for EL conspicuity on a 5-point comparative scale from 0 (best) to -4 (significantly inferior). Two experienced radiologists independently conducted a qualitative evaluation of the CT images. RESULTS: A total of 30 out of 61 patients presented with an EL. On both 40- and 70-keV images, the CNR of the EL was significantly higher in DLIR than in hybrid IR (40-keV, 14.5 ± 7.3 vs 8.6 ± 4.2, P<0.001; 70-keV, 8.7 ± 4.5 vs 5.5 ± 2.6, P<0.001). The comparative scale of EL conspicuity in the 40-keV DLIR images (Observer1, -0.2 ± 0.4; Observer2, 0.0 ± 0.0) was significantly higher than 40-keV hybrid IR (Observer1, -0.5 ± 0.5; Observer2, -1.0 ± 0.0; P<0.05), 70-keV DLIR (Observer1, -1.8 ± 0.4; Observer2, -2.0 ± 0.0; P<0.001) and 70-keV hybrid IR images (Observer1, -1.8 ± 0.4; Observer2, -2.4 ± 0.5; P<0.001), respectively. CONCLUSIONS: Using 40-keV VMI in combination with DLIR improves EL delineation after EVAR compared with the 70-keV VMI with hybrid IR or DLIR.
Asunto(s)
Aprendizaje Profundo , Endofuga , Tomografía Computarizada por Rayos X , Humanos , Masculino , Anciano , Femenino , Endofuga/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Procedimientos Endovasculares/métodos , Medios de Contraste , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Anciano de 80 o más Años , Estudios Retrospectivos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagenRESUMEN
BACKGROUND: The INCRAFT stent graft system is an ultra-low-profile endograft for the exclusion of infrarenal aortic aneurysms. In the market approval studies, an increased rate of device-related complications was observed and the endograft was approved with mandated postmarketing investigations. Our aim was to analyze mid-term outcomes of a real-world patient cohort treated with the INCRAFT endograft. METHODS: Consecutive patients treated with the INCRAFT endograft between February 2015 and December 2022 at a single institution were included. In accordance with the Society for Vascular Surgery reporting standards, safety endpoints were reported and outcome endpoints included reinterventions, technical success, aortic-related and overall-mortality, endoleak, stent fracture, and endograft migration >5 mm. RESULTS: Eighty patients (85% male) with a mean age of 76 ± 7 years were included. Fifty-two patients (65%) were treated within the endograft's instruction for use. Mean aortic diameter was 59 ± 10 mm and 91% of the procedures were performed percutaneously. Mean follow-up (FU) was 37 ± 25 months and there was no aortic- or procedure-related mortality. Reinterventions occurred in 25 patients (31%) with a freedom from reintervention at 1, 3, and 5 years of 84%, 66%, and 55%. The most frequent reinterventions were limb graft stenting (23%) and type II endoleak embolization (14%). Limb occlusion rate was 9% and in 3 patients (4%) distal endograft migrations >5 mm occurred. Persisting type II endoleaks were observed in 29% and aneurysm diameter was stable in 41% and had shrunk in 38%. Three type III endoleaks (4%) developed during FU and 4 open conversions (5%) were necessary. No known risk factors, including treatment outside instruction for use, were predictive for reinterventions. CONCLUSIONS: Treatment of infrarenal aortic aneurysms with the INCRAFT stent graft system was safe and successful. Nevertheless, a substantial rate of reinterventions was necessary during FU to maintain endograft patency and prevent aneurysm growth.
Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Diseño de Prótesis , Stents , Humanos , Masculino , Anciano , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Femenino , Factores de Tiempo , Anciano de 80 o más Años , Resultado del Tratamiento , Factores de Riesgo , Estudios Retrospectivos , Endofuga/etiología , Retratamiento , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Migración de Cuerpo Extraño/etiología , Falla de Prótesis , Medición de RiesgoRESUMEN
BACKGROUND: The association between the occlusion rate of the side branch arteries branching from the abdominal aortic aneurysm sac and aneurysm sac shrinkage is unclear. We aimed to evaluate the efficacy of preemptive embolization of multiple side branch arteries branching from the abdominal aortic aneurysm sac in early aneurysm sac shrinkage after endovascular aneurysm repair. METHODS: Patients undergoing endovascular aneurysm repair of abdominal aortic aneurysms, with or without preemptive embolization of multiple side branch arteries, including the inferior mesenteric artery and lumbar arteries, between January 2016 and August 2021, were retrospectively evaluated. Preemptive embolization was introduced at our institution in January 2018 and has been performed in all patients who undergo endovascular aneurysm repair since then. We compared occlusion rates of the side branch arteries, frequency of type 2 endoleaks, changes in aneurysm sac size, percentage of aneurysm sac size decrease, and frequency of reduction in the aneurysm sac diameter by > 5 mm. RESULTS: The study included 43 patients in the embolization group and 20 in the nonembolization group. Preemptive embolization was successfully performed without any ischemic complications. The total occlusion rate of side branch arteries was significantly higher in the embolization group than in the nonembolization group (70.2% vs. 29.3%, P < 0.05). At 24 months of follow-up, the type 2 endoleak frequency was significantly lower in the embolization group than in the nonembolization group (6.9% vs. 31.6%, P < 0.05). The frequency of reduction in the aneurysm sac diameter by > 5 mm was significantly higher in the embolization group than in the nonembolization group at 24 months (62.1% vs. 31.6% P < 0.05). The optimal cutoff value for the total occlusion rate of the side branch arteries to achieve reduction in the aneurysm sac diameter by > 5 mm at 24 months, after endovascular aneurysm repair, was 66.7% in all patients (area under the curve = 0.634; sensitivity = 62.5%; specificity = 70.8%). These findings suggest that occluding 66.7% or more of the side branch arteries may result in early aneurysmal shrinkage. CONCLUSIONS: Preemptive embolization of multiple side branch arteries, branching from the abdominal aortic aneurysm sac, may contribute to early aneurysm sac shrinkage; this may serve as a marker for fewer late complications after endovascular aneurysm repair.
Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Embolización Terapéutica , Endofuga , Procedimientos Endovasculares , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Estudios Retrospectivos , Embolización Terapéutica/efectos adversos , Procedimientos Endovasculares/efectos adversos , Masculino , Femenino , Anciano , Resultado del Tratamiento , Implantación de Prótesis Vascular/efectos adversos , Factores de Tiempo , Endofuga/etiología , Endofuga/prevención & control , Endofuga/terapia , Endofuga/diagnóstico por imagen , Anciano de 80 o más Años , Arteria Mesentérica Inferior/diagnóstico por imagen , Arteria Mesentérica Inferior/fisiopatología , Factores de Riesgo , Reparación Endovascular de AneurismasRESUMEN
BACKGROUND: Variations in sac shrinkage (SS) are noted between endovascular aneurysm repair for abdominal aortic aneurysm (AAA) and fenestrated endovascular aneurysm repair for short neck AAA. These variations may originate from difference in the geometry and length of proximal sealing, which influences the quality and durability of the seal. This study aimed to explore the disparities in aneurysm exclusion and sac remodeling across these 2 scenarios. METHODS: This study involved a retrospective analysis of prospectively collected data from 2014 to 2021. Of 486 endovascular abdominal aortic repair cases, 33 that exclusively used a low permeability expanded polytetrafluoroethylene infrarenal device, strictly adhering to the instructions for use (IFUs), were selected. Concurrently, 30 cases of fenestrated repair that utilized modified polyester woven fabric devices proximally with consistent use of the aforementioned low-permeability devices infrarenally were examined. The quality of both proximal and distal sealing zones in fenestrated repairs was maintained within the range specified in the expanded polytetrafluoroethylene infrarenal device's IFUs, ensuring consistent sealing integrity for reliable group comparisons. Key metrics used for analysis were the detection of endoleaks and measurements of sac dimensions. Additional analyses included comparisons of demographic data and postoperative diameter changes in the proximal sealing zone (PZ) (encompassing 0, 5, 10, 15, and 20 mm below the most proximal sealing stent). RESULTS: The demographic data and preoperative maximum-minimum diameter of the aneurysms did not differ between the groups. Proximal neck dilatation was similarly observed after both procedures. Immediately after the procedure, the incidence of lumbar arterial type II endoleaks was significantly lower after fenestrated repair than that after endovascular aortic repair (EVAR, 10% vs. 39.4%, P = 0.0094). At the final observation, EVAR substantially reduced the PZ length (-4.73 ± 15.30%), while fenestrated repair maintained the length (21.98 ± 24.34%; P < 0.0001). The preservation of the sealing length in fenestrated repairs was attributable to dilation occurring within the sealing range of the proximal device, oversized to accommodate the larger diameters in the more proximal sections of the aorta. The cumulative occurrence of SS (>5 mm) following fenestrated repair increased faster than that after endovascular repair (P = 0.002). CONCLUSIONS: Although aortic neck dilatation progressed similarly in both groups, fenestrated repair maintained the sealing length and demonstrated a greater extent of SS, even under the challenging circumstances in PZ. The superior postoperative results were linked to both the durability of proximal sealing and a lower occurrence of lumbar arterial type II endoleaks, stemming from the effective shuttering of the collateral sources in the proximal lumbar or intercostal arteries.
Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Endofuga , Procedimientos Endovasculares , Diseño de Prótesis , Stents , Humanos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Femenino , Masculino , Anciano , Resultado del Tratamiento , Factores de Tiempo , Anciano de 80 o más Años , Endofuga/etiología , Endofuga/cirugía , Factores de Riesgo , Politetrafluoroetileno , Reparación Endovascular de AneurismasRESUMEN
We present a rare case of short-segment jejunal infarction following inferior mesenteric artery embolisation for type 2 endoleak in a patient who previously underwent endovascular repair of abdominal aortic aneurysm. Potential causes for the event might include thromboembolism or traumatic thrombosis of a jejunal branch of the superior mesenteric artery (SMA) caused by a buddy guide wire used to maintain the position of the long vascular sheath in the SMA hiatus. The condition was recognised on CT and treated with resection of the infarcted segment of the small bowel followed by primary anastomosis.
Asunto(s)
Embolización Terapéutica , Endofuga , Yeyuno , Arteria Mesentérica Inferior , Humanos , Arteria Mesentérica Inferior/diagnóstico por imagen , Embolización Terapéutica/métodos , Endofuga/etiología , Endofuga/diagnóstico por imagen , Endofuga/terapia , Yeyuno/irrigación sanguínea , Yeyuno/cirugía , Masculino , Aneurisma de la Aorta Abdominal/cirugía , Isquemia/etiología , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/efectos adversos , Tomografía Computarizada por Rayos X , AncianoRESUMEN
OBJECTIVES: To develop and validate a deep learning model for detecting post-endovascular aortic repair (EVAR) endoleak from non-contrast CT. METHODS: This retrospective study involved 245 patients who underwent EVAR between September 2016 and December 2022. All patients underwent both non-enhanced and enhanced follow-up CT. The presence of endoleak was evaluated based on computed tomography angiography (CTA) and radiology reports. First, the aneurysm sac was segmented, and radiomic features were extracted on non-contrast CT. Statistical analysis was conducted to investigate differences in shape and density characteristics between aneurysm sacs with and without endoleak. Subsequently, a deep learning model was trained to generate predicted segmentation of the endoleak. A binary decision was made based on whether the model produced a segmentation to detect the presence of endoleak. The absence of a predicted segmentation indicated no endoleak, while the presence of a predicted segmentation indicated endoleak. Finally, the performance of the model was evaluated by comparing the predicted segmentation with the reference segmentation obtained from CTA. Model performance was assessed using metrics such as dice similarity coefficient, sensitivity, specificity, and the area under the curve (AUC). RESULTS: This study finally included 85 patients with endoleak and 82 patients without endoleak. Compared to patients without endoleak, patients with endoleak had higher CT values and greater dispersion. The AUC in validation group was 0.951, dice similarity coefficient was 0.814, sensitivity was 0.877, and specificity was 0.884. CONCLUSION: This deep learning model based on non-contrast CT can detect endoleak after EVAR with high sensitivity.
Asunto(s)
Aneurisma de la Aorta Abdominal , Angiografía por Tomografía Computarizada , Aprendizaje Profundo , Endofuga , Procedimientos Endovasculares , Humanos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Estudios Retrospectivos , Masculino , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/efectos adversos , Femenino , Anciano , Angiografía por Tomografía Computarizada/métodos , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/efectos adversos , Valor Predictivo de las Pruebas , Reparación Endovascular de AneurismasRESUMEN
OBJECTIVE: The aim of this study was to evaluate the effect of fenestration configuration and fenestration gap on renal artery outcomes during fenestrated-branched endovascular aortic repair (F/BEVAR). METHODS: A retrospective multicenter analysis was performed, including patients with complex aortic aneurysms treated with F/BEVAR that incorporated at least one small fenestration to a renal artery. The renal fenestrations were divided into groups 1 (8 × 6 mm) and 2 (6 × 6 mm). Primary patency, target vessel instability (TVI), freedom from secondary interventions (SIs), occurrence of type IIIc endoleak, all related to the renal arteries, were analyzed at 30-day, 1-year, and 5-year landmarks. The fenestration gap (FG) distance was analyzed as a modifier, and clustering was addressed at the patient level. RESULTS: A total of 796 patients were included in this study, 71.7% male, with a mean age of 73.3 ± 8.1 years. The mean follow-up was 30.0 ± 20.6 months. Of the 1474 small renal fenestrations analyzed, 47.6% were 8 × 6 mm, and 52.4% were 6 × 6 mm. At the 30-day landmark, primary patency (99.9% vs 98.0%; P value < .001 for groups 1 and 2, respectively), freedom from TVI (99.6% vs 97.1%; P value < .001 for groups 1 and 2, respectively), and freedom from SI (99.8% vs 98.4%; P value = .022 for groups 1 and 2, respectively) were higher in 8 × 6 compared with 6 × 6 fenestrations, and the incidence of acute kidney injury was similar across the groups (92.6% vs 92.7%; P value = .953 for groups 1 and 2 respectively). The primary patency at 1 and 5 years was higher in 8 × 6 fenestrations (1-year: 98.8% vs 96.9%; 5-year: 97.8% vs 95.7%, for groups 1 and 2, respectively, P values = .010 and .021 for 1 and 5 year comparisons, respectively). The freedom from SIs was significantly higher among 6 × 6 fenestrations at 5 years (93.1% vs 96.4%, for groups 1 and 2, respectively, P value = .007). The groups were equally as likely to experience a type Ic endoleak (1.3% and 1.6% for 8 × 6 and 6 × 6mm fenestrations, respectively, P = .689). The 6 × 6 fenestrations were associated with higher risk of kidney function deterioration (17.8%) when compared with 8 × 6 fenestrations (7.6%) at 5 years (P < .001). The risk of type IIIc endoleak was significantly higher among 8 × 6 fenestrations at 5 years (4.9% and 2% for 8 × 6 and 6 × 6 mm fenestrations, respectively; P = .005). A FG ≥5 mm negatively impacted the cumulative 5-year freedom from TVI (group 1: FG ≥5 mm = 0.714, FG <5 mm = 0.857; P < .001; group 2: FG ≥5 mm = 0.761, FG <5 mm = 0.929; P < .001) and the cumulative 5-year freedom from type IIIc endoleak (group 1: FG ≥5 mm = 0.759, FG <5 mm = 0.921; P = .034; group 2: FG ≥5 mm = 0.853, FG <5 mm = 0.979; P < .001) in both groups and the cumulative 5-year patency in group 2 (group 1: FG ≥5 mm = 0.963, FG <5 mm = 0.948; P = .572; group 2: FG ≥5 mm = 0.905, FG <5 mm = 0.938; P = .036). CONCLUSIONS: Fenestration configuration for the renal arteries impacts outcomes. The 8 × 6 small fenestrations have better patency at 30 days, 1 year, and 5 years, whereas 6 × 6 small fenestrations are associated with lower rates of SIs, primarily due to a lower incidence of type IIIc endoleaks. FG ≥5 mm at the level of the renal arteries significantly impacts the freedom from TVI, freedom from type IIIc endoleak, and 5-year patency independently of the fenestration size or vessel diameter.