Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 650
Filtrar
1.
J Cardiothorac Surg ; 19(1): 416, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38961402

RESUMEN

BACKGROUND: The occurrence of type II endoleaks after endovascular repair of aortic aneurysm has gradually gained increasing attention. We present a case of a patient with an expanding aneurysm after thoracic endovascular aortic repair (TEVAR) for a type II endoleak, in which successful direct ligations of the intercostal artery were performed using a sac incision without cardiopulmonary bypass (CPB) or graft replacement. CASE PRESENTATION: A 62-year-old male patient, previously treated with TEVAR for a descending thoracic aortic aneurysm, presented with ongoing chest discomfort. Based on the diagnosis of a growing aneurysm and type II endoleak, the patient was prepared for CPB and aortic cross-clamping, as a precautions against the possibility of a type I endoleak. A longitudinal opening of the thoracic aortic aneurysm sac was performed following left thoracotomy. Visual confirmation identified the T5 level intercostal artery as the source of the endoleak, and after confirming the absence of a type I endoleak, multiple ligations were applied to the intercostal artery. Follow-up computed tomography confirmed the absence of endoleaks or sac growth. CONCLUSION: In a case involving TEVAR for a thoracic aortic aneurysm, open suture ligations were used to treat type II endoleaks without having to resort to CPB, resulting in successful outcomes.


Asunto(s)
Aneurisma de la Aorta Torácica , Endofuga , Procedimientos Endovasculares , Humanos , Masculino , Endofuga/cirugía , Endofuga/etiología , Persona de Mediana Edad , Aneurisma de la Aorta Torácica/cirugía , Procedimientos Endovasculares/métodos , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/efectos adversos , Tomografía Computarizada por Rayos X , Aorta Torácica/cirugía , Ligadura , Reparación Endovascular de Aneurismas
3.
Expert Rev Med Devices ; 21(3): 165-177, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38431273

RESUMEN

INTRODUCTION: With the incidence of thoracic aortic disease on the rise, total arch replacement (TAR) with frozen elephant trunk (FET) remains the gold-standard management strategy due to optimal results. Several FET devices exist commercially on the global market. However, the mainstay and most commonly used and reported device is the Thoraflex Hybrid Prosthesis (THP), with several recent reports suggesting its superiority. AREAS COVERED: This review aims to collate and summarize the evidence in the literature on the clinical outcomes of TAR with FET using THP, with a focus on mortality, neurological complications, endoleak, distal stent-induced new entry (dSINE), aortic remodeling, coagulopathy, and graft kinking. In addition, the design features of THP is discussed, and an overview of market competitors is also highlighted. EXPERT OPINION: THP consistently demonstrates its effectiveness in treating complex thoracic aortic pathology through favorable clinical outcomes, which can be attributed to its unique and innovative design. Rates of early mortality ranged 0.6-14.2%, neurological complications 0-25%, endoleak 0-8.4% and dSINE 0-14.5%, with minimal incidence of graft kinking and coagulopathy. Aortic remodeling is favorable and comparable to competitors. All this evidence solidifies THP as the leading FET device, particularly when combined with appropriate patient selection and surgical planning.


Asunto(s)
Disección Aórtica , Implantación de Prótesis Vascular , Humanos , Prótesis Vascular , Endofuga/cirugía , Stents , Aorta Torácica/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
4.
Kyobu Geka ; 77(2): 136-139, 2024 Feb.
Artículo en Japonés | MEDLINE | ID: mdl-38459863

RESUMEN

A 67-year-old male was admitted to our hospital for sudden onset chest pain and hoarseness. He underwent 2-debranching thoracic endovascular aortic repair for a ruptured aortic arch aneurysm four years prior. However, computed tomography (CT) revealed an aneurysmal rerupture due to a typeⅠa endoleak. We performed partial arch replacement with uncovered stent removal under intermittent hypothermic circulatory arrest. We needed to be more careful than usual open heart surgery because a non-anatomical bypass procedure was performed. The surgery was successful without any major complications, and the patient was discharged on the 23th postoperative day. Reinterventions post-endovascular repair are sometimes difficult;thus, open surgery could be useful for arch replacement.


Asunto(s)
Aneurisma del Arco Aórtico , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Anciano , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/cirugía , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Implantación de Prótesis Vascular/efectos adversos , Stents/efectos adversos , Resultado del Tratamiento , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Prótesis Vascular/efectos adversos , Estudios Retrospectivos
7.
Eur J Vasc Endovasc Surg ; 68(1): 40-48, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38490356

RESUMEN

OBJECTIVE: The midterm outcomes of the low profile Zenith Alpha Abdominal Endovascular Graft from the ZEnith alPHa for aneurYsm Repair (ZEPHYR) registry are reported. METHODS: The ZEPHYR registry is a physician initiated, multicentre, non-randomised, core laboratory controlled, prospective registry. Inclusion criteria were patients with a non-ruptured abdominal aortic aneurysm with a maximum diameter ≥ 50 mm or enlargement > 5 mm within 6 months, with a site reported infrarenal neck length of ≥ 10 mm and with the intention to electively implant the Zenith Alpha abdominal endograft. Patients from 14 sites across Germany, Belgium, and the Netherlands were included. The primary endpoint was treatment success, defined as technical success and clinical success. Technical success was defined as successful delivery and deployment of the endograft in the planned position without unintentional coverage of internal iliac or renal arteries, with successful removal of the delivery system. Clinical success was defined as freedom from aneurysm sac expansion > 5 mm, type I or type III endoleaks, aneurysm rupture, stent graft migration > 10 mm, open conversion, and stent graft occlusion. RESULTS: Three hundred and forty-seven patients were included in the ZEPHYR registry. The median clinical follow up was 743 days (interquartile range [IQR] 657, 806) with a median imaging follow up of 725 days (IQR 408, 788). Treatment success at 6 months, 1, and 2 years was 92.5%, 90.4%, and 85.3%, respectively. Freedom from secondary intervention was 94.3%, 93.4%, and 86.9%, respectively. The predominant reason for secondary intervention was limb complications. Freedom from limb occlusion (per patient) at 6 months, 1, and 2 years was 97.2%, 95.8%, and 92.5%, respectively. Univariable and multivariable Cox regression analyses could not identify any independent predictor for limb complications. CONCLUSION: While treatment success is comparable with other commercially available grafts, the rate of limb complications at 2 years is of concern. The manufacturer's instructions for use should be followed closely. Further studies are necessary to investigate the root cause of the increased rate of limb complications with the Zenith Alpha Abdominal Endovascular Graft.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Diseño de Prótesis , Sistema de Registros , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Masculino , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Femenino , Anciano , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Estudios Prospectivos , Resultado del Tratamiento , Anciano de 80 o más Años , Factores de Tiempo , Stents , Endofuga/etiología , Endofuga/cirugía , Países Bajos , Factores de Riesgo , Alemania , Bélgica
8.
J Surg Res ; 296: 516-522, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38330677

RESUMEN

INTRODUCTION: Recent data suggests that infrarenal abdominal aortic aneurysm (AAA) endovascular repair (EVAR) with large diameter grafts (LGs) may have a higher risk of endoleak and reintervention. However, this has not been studied extensively for fenestrated endovascular aneurysm repair (fEVAR). We, therefore, sought to evaluate the outcomes of patients undergoing fEVAR with large-diameter endografts. METHODS: Patients from the national Vascular Quality Initiative registry who underwent fEVAR for intact juxtarenal AAA were identified. Patients with genetic causes for aneurysms, those with prior aortic surgery, and those undergoing repair for symptomatic or ruptured aneurysms were excluded. Rates of endoleaks and reintervention at periprocedural and long-term follow-up timepoints (9-22 mo) were analyzed in grafts 32 mm or larger (LG) and were compared to those smaller than 32 mm (small diameter graft). RESULTS: A total of 693 patients (22.8% LG) were identified. Overall, demographic variables were comparable except LG exhibited a more frequent history of coronary artery disease (32.9% versus 25.4%, P = 0.037). There were no significant differences in the rates of endoleak at procedural completion. Overall survival at 5 y was no different. The rate of reintervention at 1 y was also no different (log-rank P = 0.86). CONCLUSIONS: While graft size appears to have an association with outcomes in infrarenal aneurysm repair, the same does not appear to be true for fEVAR. Further studies should evaluate the long-term outcomes associated with LG which could alter the approach to repair of AAA with large neck diameters traditionally treated with standard infrarenal EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/etiología , Endofuga/cirugía , Resultado del Tratamiento , Factores de Riesgo , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Diseño de Prótesis
9.
J Vasc Surg ; 79(6): 1369-1378, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38316346

RESUMEN

OBJECTIVE: There are a variety of methods used today to treat common iliac aneurysms with endovascular techniques. Of these approaches, little is known about whether a particular limb strategy influences endoleak, reintervention, or aneurysm regression rates. We present 5-year data comparing endoleak, stent graft migration, fracture, aneurysm sac dynamics, and aortic rupture rates among patients treated with bell bottom limbs (BB), iliac branch endoprosthesis (IBE), and coil and cover (CC) approaches from the Global Registry for Endovascular Aortic Treatment registry. Secondary end points were all-cause mortality, stroke, reintervention, and paraplegia. METHODS: Subjects from the GORE Global Registry for Endovascular Aortic Treatment were enrolled over a 5-year period from October 2017 to August 2022. We included 924 subjects in this study. Statistical data was generated on R software and limb groups were compared using the Pearson's χ2 test and the Kruskal-Wallis rank-sum test. RESULTS: We found no statistical difference in endoleak rates, stent graft migration, fracture, or aortic rupture when stratified by limb strategy. There was no difference between limb approaches with regard to aneurysm sac dynamics among those with abdominal aortic aneurysms and common iliac aneurysms. Similarly, no statistical difference between limb strategies was found in all-cause mortality, stroke, paraplegia, or reintervention rates. Among patients that required an additional graft during reintervention, the highest rates were found within the IBE group 8.6%, compared with BB group 2.2% and CC group 1.3% (P = .006). CONCLUSIONS: Overall, there was no difference among limb strategies in endoleak rates, stent graft migration, aneurysm sac dynamics, aortic rupture rates, or our secondary end points. Increased rates of reintervention requiring an additional graft within the IBE group is noteworthy and must be weighed against the adverse effects of hypogastric sacrifice with the CC approach or potentially less advantageous seal zones in the BB approach. This finding suggests that all limb approaches have equivalent effectiveness in managing the aneurysmal common iliac artery; thus, the choice of limb strategy should be individualized and remain at physician discretion. Future research should include a more robust sample size to reproduce these findings.


Asunto(s)
Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Aneurisma Ilíaco , Diseño de Prótesis , Sistema de Registros , Stents , Humanos , Aneurisma Ilíaco/cirugía , Aneurisma Ilíaco/mortalidad , Aneurisma Ilíaco/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Masculino , Femenino , Resultado del Tratamiento , Factores de Tiempo , Anciano , Factores de Riesgo , Endofuga/etiología , Endofuga/cirugía , Anciano de 80 o más Años , Rotura de la Aorta/cirugía , Rotura de la Aorta/mortalidad , Rotura de la Aorta/diagnóstico por imagen , Falla de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Migración de Cuerpo Extraño/etiología
10.
J Vasc Surg ; 79(5): 1090-1100.e4, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38185214

RESUMEN

OBJECTIVE: To determine the safety and efficacy of treating abdominal aortic aneurysm (AAA) sacs with polyurethane shape memory polymer (SMP) devices during endovascular aneurysm repair (EVAR), using a technique to fully treat the target lumen after endograft placement (aortic flow volume minus the endograft volume). SMP devices self-expand in the sac to form a porous scaffold that supports thrombosis throughout its structure. METHODS: Two identical prospective, multicenter, single-arm studies were conducted in New Zealand and the Netherlands. The study population was adult candidates for elective EVAR of an infrarenal AAA (diameter of ≥55 mm in men and ≥50 mm in women). Key exclusion criteria were an inability to adequately seal a common iliac artery aneurysm, patent sac feeding vessels of >4 mm, and a target lumen volume of <20 mL or >135 mL. Target lumen volumes were estimated by subtracting endograft volumes from preprocedural imaging-based flow lumen volumes. SMP devices were delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. The primary efficacy end point was technical success, defined as filling the actual target lumen volume with fully expanded SMP at the completion of the procedure. Secondary efficacy outcome measures during follow-up were the change in sac volume and diameter, rate of type II endoleak and type I or III endoleaks, and the rate of open repair and related reinterventions, with data collection at 30 days, 6 months, and 1 year (to date). Baseline sac volumes and diameters for change in sac size analyses were determined from 30-day imaging studies. Baseline and follow-up volumes were normalized by subtraction of the endograft volume. RESULTS: Of 34 patients treated with SMP devices and followed per protocol, 33 patients were evaluable at 1 year. Preprocedural aneurysm volume was 181.4 mL (95% confidence interval [CI], 150.7-212.1 mL) and preprocedural aneurysm diameter was 60.8 mm (95% CI, 57.8-63.9 mm). The target lumen volume was 56.3 mL (95% CI, 46.9-65.8 mL). Technical success was 100% and the ratio of SMP fully expanded volume to estimated target lumen volume was 1.4 ± 0.3. Baseline normalized sac volume and diameter were 140.7 mL (95% CI, 126.6-154.9 mL) and 61.0 mm (95% CI, 59.7-62.3 mm). The adjusted mean percentage change in normalized volume at 1 year was -28.8% (95% CI, -35.3 to -22.3%; P < .001). The adjusted mean change in sac diameter at 1 year was -5.9 mm (95% CI, -7.5 to -4.4 mm; P < .001). At 1 year, 81.8% of patients (95% CI, 64.5%-93.0%) achieved a ≥10% decrease in normalized volume and 57.6% of patients (95% CI, 39.2%-74.5%) achieved a ≥5 mm decrease in diameter. No device- or study procedure-related major adverse events occurred through 1 year after the procedure. CONCLUSIONS: Treatment of AAA sacs with SMP devices during EVAR resulted in significant sac volume and diameter regression at 1 year with an acceptable safety profile in this prospective study.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Femenino , Prótesis Vascular , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/etiología , Estudios Prospectivos , Implantación de Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Estudios de Seguimiento , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/cirugía , Factores de Riesgo
11.
Vasc Endovascular Surg ; 58(2): 151-157, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37607586

RESUMEN

PURPOSE: To evaluate the safety and effectiveness of intra-sac thrombin injection to remedy type II endoleaks (T2ELs) during endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: 224 cases abdominal aortic aneurysm (AAA) were treated with EVAR. For the 52 cases of intra-operative type II endoleaks and 8 cases of ruptured AAAs, after the grafts were deployed, thrombin was injected into the aneurysm sac through a preset catheter. The occurrence of endoleaks post-EVAR were followed up with by Computed Tomography (CT) angiogram. The diameter and the volume of the aneurysm sac were also measured. Endpoints included incidence of T2ELs, AAA sac shrinkage and re-intervention rate and all-cause mortality. RESULTS: The overall technical success rate was 100%. Fifty-two patients were followed up with for 9-56 (median 24) months. No serious complications were observed during follow-up. The incidence of endoleak was 5.8% (3/52) during follow-up. The maximum diameter of the aneurysm decreased from 61.1 ± 14.2 mm to 53.7 ± 10.6 mm, 47.9 ± 8.3 mm and 43.7 ± 7.2 mm (87.9%, 78.4% and 71.5% of pre-EVAR) at the 6-month, 1-year and 2-year follow-up, respectively (P < .05). The volume of the aneurysm sac shrank from 236.2 ± 136.2 cm3 to 202.6 ± 114.1 cm3, 155.6 ± 68.4 cm3 and 129.7 ± 52.4 cm3 (85.8%, 65.9%, and 54.9% of pre-EVAR) at the 6-month, 1-year and 2-year follow-up, respectively (P < .05). The rate of various endoleaks was 5.8% (3/52) and the re-intervention rate was 1.9% (1/52) in this research. CONCLUSIONS: Clinical outcomes show that intra-sac injection of thrombin during EVAR is safe and may be effective in remedying small amount and low-velocity endoleaks and promoting shrinkage of the aneurysm sac.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/cirugía , Reparación Endovascular de Aneurismas , Trombina/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Factores de Riesgo , Estudios Retrospectivos
14.
Ann Vasc Surg ; 99: 148-165, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37995905

RESUMEN

BACKGROUND: Over the past 3 decades endovascular aortic aneurysm repair emerged as the primary approach for abdominal aortic aneurysm management, however the occurrence of endoleak following endograft implantation imposes a high toll on patients and hospitals alike. The early diagnosis and appropriate treatment of endoleaks is associated with better outcomes, which calls for more advanced imaging and a standardized approach for endoleak diagnosis and management following endovascular aortic aneurysm repair. Although conventional strategy with non-targeted deployment of coils and embolic material in the aneurysm sac is considered to be the standard approach in many hospitals, it may not prove to be a viable option, given that it affects any further follow-up imaging in the event of sub-optimal therapy and consequent recurrence. METHODS: Based on our tertiary aortic referral center experience we summarize and describe strategies for optimal selection of various treatment approaches for Type-II Endoleak management including endovascular, percutaneous and laparoscopic approaches with particular focus on intraoperative image guidance techniques. RESULTS: After failed conventional endovascular embolization attempt we recommend specific complex type II endoleak management approaches based on the location of the endoleak within the aneurysm sac along the x, y and z axis. A transabdominal or laparoscopic approach enable treatment in endoleaks located in the anterior portion of the sac. Endoleaks in the posterior portion of the sac could be treated using the transcaval or the translumbar approach, depending on whether the endoleak is situated on the left or the right side. Alternative strategies should be considered if patient anatomy does not allow for either transcaval or translumbar approach. The transgraft technique is reserved for endoleaks located in the cranial portion of the sac, while the perigraft approach could present a means of treatment for endoleaks situated in the caudal portion of the aneurysm sac. CONCLUSION: We encourage establishing a patient specific treatment plan in accordance with individual anatomy based on cross sectional imaging modality (time resolved dynamic imaging in selected cases) and intraoperative image guidance to provide a safe and accurate endoleak localization and embolization for patients undergoing type II endoleak treatment.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Embolización Terapéutica , Procedimientos Endovasculares , Humanos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/cirugía , Resultado del Tratamiento , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/etiología , Embolización Terapéutica/efectos adversos , Estudios Retrospectivos
15.
J Ultrasound Med ; 43(3): 429-437, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37972197

RESUMEN

OBJECTIVES: Several imaging modalities have been suggested for surveillance after fenestrated endovascular aortic repair in general and endoleak detection in specific. In the present project a coded excitation-based ultrasound (B-Flow) was investigated for endoleak detection after complex endovascular aortic repair. METHODS: Patients post complex endovascular aortic repair (FEVAR or T/FEVAR) undergoing follow-up appointments including ultrasonography of the aorta at a vascular and endovascular surgery outpatient center were included in the study. B-Flow was compared with computed tomography angiography (CTA), Duplex ultrasound (DUS), and contrast-enhanced ultrasound (CEUS) regarding agreement and reliability for endoleak detection and characterization. RESULTS: In total, 47 follow-ups were included. They accumulated in a total of 149 imaging investigations. Endoleaks were discovered in 44.7% of B-Flow studies and a majority of these endoleaks were classified as type II. Agreement between B-Flow and other imaging modalities was good (>80.0%) in general. However, with B-Flow 6 and 2 endoleaks would have been missed compared with CEUS and CTA, respectively. Regarding endoleak classification, B-Flow had a strong agreement (94.5%) with CEUS in detected cases. Furthermore, in a limited subset analysis, imaging findings were externally validated using findings from angiography. CONCLUSIONS: Ultrasonography allows for endoleak detection and characterization without an invasive procedure or the use of potentially nephrotoxic contrast medium and can reduce radiation exposure. While CEUS mitigates issues of radiation and nephrotoxicity it still requires the intravenous application of contrast enhancers. Ultrasound coded-excitation imaging such as B-Flow could therefore further simplify endoleak surveillance after fenestrated endovascular aortic repair.


Asunto(s)
Aneurisma de la Aorta Abdominal , Procedimientos Endovasculares , Humanos , Reparación Endovascular de Aneurismas , Medios de Contraste , Endofuga/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Reproducibilidad de los Resultados , Ultrasonografía , Resultado del Tratamiento
16.
Eur J Vasc Endovasc Surg ; 67(4): 612-619, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37992984

RESUMEN

OBJECTIVE: This study aimed to investigate the correlation between aneurysm sac behaviour and time to re-intervention after endovascular aneurysm repair (EVAR). METHODS: A retrospective observational cohort study of patients who underwent EVAR at a single centre between January 2008 and November 2011 and who were followed up for a mean of 6.6 ± 2.9 years was conducted. Based on sac appearances on pre-operative imaging and imaging at the end of follow up, patients were stratified into two groups: (1) sac regression; and (2) no sac regression. The no sac regression group was further subdivided into stable sac group and sac expansion group. Sac regression and expansion throughout follow up were defined as a decrease or increase in the abdominal aortic aneurysm sac diameter of ≥ 5 mm compared with the pre-operative size. A Cox proportional hazards model using multiple failure per subject data was used to identify sac behaviour as a predictor of re-intervention free time. RESULTS: Patients with sac regression had a higher probability of freedom from re-intervention compared with those with a stable or expanding aneurysm sac (94%, 57%, and 16% at 12 years, respectively; log rank, p < .001). Mean time to re-intervention was 11.3 years for the sac regression group, 8.8 years for the stable sac group, and 5.0 years for the sac expansion group (p < .001). In the stable sac group, the risk of re-intervention increased sharply six years after EVAR, whereas in the sac expansion group a sharp rise in re-intervention was noted 3.5 years after EVAR, reaching a plateau after year 6. CONCLUSION: A time dependent correlation between aneurysm sac behaviour and re-intervention was found. Such findings have implications for surveillance strategies.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Reparación Endovascular de Aneurismas , Resultado del Tratamiento , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Estudios Retrospectivos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Factores de Riesgo , Factores de Tiempo , Endofuga/cirugía
17.
Ann Vasc Surg ; 99: 332-340, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37839654

RESUMEN

BACKGROUND: The endovascular repair of infrarenal abdominal aortic aneurysms can be performed with a wide variety of devices. Many of these grafts elevate the aortic bifurcation which can limit future repairs if the graft material fails thereby creating a type III endoleak to aorto-uniliac grafts. Many manufacturers have grafts susceptible to this, but we have seen this in the Medtronic AneuRx graft. Our goal is to provide technical details and outcomes regarding a novel technique to reline these grafts while maintaining inline flow to the iliac arteries. METHODS: This was a single-institution review of patients who had endoleaks requiring intervention after a previously placed graft with an elevated aortic bifurcation. Primary outcomes included technical success defined as placement of all planned devices, resolution of type III endoleak, aneurysm size at follow-up, and requirement of reintervention. Secondary outcomes included 30-day complications, aneurysm-related mortality, and all-cause mortality. Technical details of the operation include back-table deployment of an Ovation device, modification of the deployment system tether and pre-emptive placement of an up and over 0.014″ wire. The wire is placed up and over and hung outside the contralateral gate. Once the main body is introduced above the old graft, the 0.014" is snared from the contralateral side and externalized. The main body is then able to be seated at the bifurcation as the limb is not fully deployed and then device deployment is completed per instructions for use. RESULTS: Our study consists of 4 individuals, 3 of which had an abdominal aortic aneurysm initially managed with an AneuRx endovascular aneurysm repair and 1 with a combination of Gore and Cook grafts. All 4 patients were male with an average age of 84.5 years at time of reline. All patients had at least 10 years between initial surgery and reline at our institution. Primary outcomes revealed no type 1 or 3 endoleaks at follow-up, technical success was 100% and 1 patient required reintervention for aneurysm growth and type 2 endoleak. In terms of our secondary outcomes, there was 1 postoperative complication which was cardiac dysfunction secondary to demand ischemia, aneurysm-related mortality was 0% and all-cause mortality was 25% at average follow-up of 2.44 years. CONCLUSIONS: As individuals continue to age, there are more patients who would benefit from less invasive reinterventions following endovascular aneurysm repair. Whether this is due to aortic degeneration, stent migration, or stent material damage is not always known. In this study, we present an endovascular approach to treating type III endoleak patients with a previous graft and elevated aortic bifurcation using Ovation stent grafts and found no evidence of type 1 or 3 endoleaks on follow-up imaging. This approach may allow patients with type III endoleak the option of a minimally invasive, percutaneous approach where they previously would not have had one.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Anciano de 80 o más Años , Femenino , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/cirugía , Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Reparación Endovascular de Aneurismas , Factores de Riesgo , Resultado del Tratamiento , Stents/efectos adversos , Diseño de Prótesis
19.
Comput Methods Programs Biomed ; 244: 107993, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38142515

RESUMEN

BACKGROUND AND OBJECTIVE: Endovascular aortic aneurysm repair (EVAR) has become the standard treatment for abdominal aortic aneurysms in most centers. However, proximal sealing complications leading to endoleaks and migrations sometimes occur, particularly in unfavorable aortic anatomies and are strongly dependent on biomechanical interactions between the aortic wall and the endograft. The objective of the present work is to develop and validate a computational patient-specific model that can accurately predict these complications. METHODS: Based on pre-operative CT-scans, we developed finite element models of the aorta of 10 patients who underwent endovascular aortic aneurysm repair, 7 with standard morphologies and 3 with unfavorable anatomies. We simulated the deployment of stent grafts in each aorta by solving mechanical equilibrium with a virtual shell method. Eventually we compared the actual stent ring positions from post-operative computed-tomography-scans with the predicted simulated positions. RESULTS: A successful deployment simulation could be performed for each patient. Relative radial, transverse and longitudinal deviations were 6.3 ± 4.4%, 2.5 ± 0.9 mm and 1.4 ± 1.1 mm, respectively. CONCLUSIONS: The numerical model predicted accurately stent-graft positions in the aortic neck of 10 patients, even in complex anatomies. This shows the potential of computer simulation to anticipate possible proximal endoleak complications before EVAR interventions.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Simulación por Computador , Resultado del Tratamiento , Diseño de Prótesis , Endofuga/etiología , Endofuga/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Estudios Retrospectivos , Factores de Riesgo , Aortografía/efectos adversos , Aortografía/métodos
20.
Ann Vasc Surg ; 98: 108-114, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37453469

RESUMEN

BACKGROUND: One of the most important factors that affects the success of Endovascular Aortic Repair (EVAR) treatment is the morphology of the neck of the aneurysm. Today, EVAR can be performed even in patients who do not meet the Instruction For Use criteria with hostile neck risk factors; thanks to the developing experience and technology. Our aim in this study was to determine risk factors for Type 1a endoleaks in patients who underwent EVAR and predictive factors for Type 1a endoleaks in patients with combinations of these risk factors. METHODS: Patients who underwent elective EVAR for infrarenal abdominal aortic aneurysm in our medical center between July 2016 and January 2021 were enrolled. Of these 244 patients, 180 patients with documented preoperative and postoperative computed tomographic angiography results and a follow-up of at least 1 year were included in the study. The Mann-Whitney U test and Student's t-test were used to assess the relationship between nominal data and numerical values, and the t-test and Wilcoxon test were used to compare dependent groups. Logistic regression analysis was performed to model risk factors associated with endoleaks. RESULTS: The results showed that a neck length less than 15 mm increased the development of type 1a endoleak by 10.4 times (P < 0.001). Furthermore, a neck diameter more than 28 mm increased the development of type 1a endoleak by 21.9 times (P = 0.04). A conical neck structure (gradual neck dilation > 2 mm) increased the development of type 1a endoleaks 4.8 times (P = 0.04). The presence of calcification (> 150 Hounsfield Unit and > 2 mm) in the neck increased the risk of type 1a endoleaks fourfold (P = 0.04). Hostile neck parameters were analyzed and patients with only 1 parameter (n = 69) had a 7.2% type 1a endoleak rate, while patients with 2 parameters (n = 15) had 26.6% and patients with more than 2 parameters (n = 11) had 45.5% type 1a endoleak rate. CONCLUSIONS: Morphologic features of the neck structure of the aneurysm are among the most important parameters that affect the success of EVAR treatment. Alternative treatments should be considered in patients with more than 1 unfavorable neck parameter.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/cirugía , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Factores de Tiempo , Aortografía/métodos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Factores de Riesgo , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...