Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.096
Filtrar
1.
Radiology ; 312(1): e233265, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39012250

RESUMEN

Background Pre-existing emphysema is recognized as an indicator of future worsening in patients with chronic obstructive pulmonary disease (COPD) when observed through CT imaging. However, it remains uncertain whether additional factors, such as the spatial compactness of CT emphysema, might also serve as predictors of disease progression. Purpose To evaluate the relationship between the compactness of CT emphysema voxels and emphysema progression. Materials and Methods This secondary analysis uses data from the prospective Canadian Cohort Obstructive Lung Disease (CanCOLD) study, examining CT images obtained in participants with and without COPD at baseline and a 3-year follow-up time point (November 2009 to November 2018). Measurements of forced expiratory volume in first second of expiration (FEV1) and diffusing capacity of lung for carbon monoxide (DLco) were collected. The normalized join-count (NJC) measurement from baseline CT images and lung density (LD) changes were analyzed. Emphysema progression was defined as an annualized LD change of less than half an SD below the mean of the participants without COPD with no smoking history. Multivariable linear and logistic regression models were used to assess the association between baseline CT NJC measurements and the annualized change in LD, FEV1, DLco, and emphysema progression versus nonprogression. Results A total of 524 participants (mean age, 66 years ± 10 [SD]; 293 male) (FEV1 percent predicted, 88% ± 19; FEV1/FVC, 67% ± 9; DLco percent predicted, 105% ± 25) were analyzed, 187 (36%) of whom had COPD. CT NJC was associated with the annualized change in LD (P < .001), FEV1 (P = .02), and DLco (P = .01). Additionally, CT NJC predicted emphysema progression versus nonprogression (odds ratio, 2.24; 95% CI: 1.37, 3.50; P < .001). Conclusion The spatial distribution, or "compactness," of CT emphysema voxels predicted emphysema progression in individuals with and without COPD. ClinicalTrials.gov Identifier: NCT00920348 © RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Progresión de la Enfermedad , Enfermedad Pulmonar Obstructiva Crónica , Enfisema Pulmonar , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Enfisema Pulmonar/diagnóstico por imagen , Enfisema Pulmonar/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Estudios Prospectivos , Anciano , Persona de Mediana Edad , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Canadá , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Valor Predictivo de las Pruebas
2.
Thorax ; 79(8): 711-717, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-38914469

RESUMEN

RATIONALE: Endoscopic lung volume reduction improves lung function, quality of life and exercise capacity in severe emphysema patients. However, its effect on the diaphragm function is not well understood. We hypothesised that endoscopic lung volume reduction increases its strength by modifying its shape. OBJECTIVES: To investigate changes in both diaphragm shape and strength induced by the insertion of endobronchial valves. METHODS: In 19 patients, both the diaphragm shape and strength were investigated respectively by 3D Slicer software applied on CT scans acquired at functional residual capacity and by transdiaphragmatic pressure measurements by bilateral magnetic stimulation of the phrenic nerves before and 3 months after unilateral valves insertion. MEASUREMENTS AND MAIN RESULTS: After lung volume reduction (median (IQR), 434 mL (-597 to -156], p<0.0001), diaphragm strength increased (transdiaphragmatic pressure: 3 cmH2O (2.3 to 4.2), p<0.0001). On the treated side, this increase was associated with an increase in the coronal (16 mm (13 to 24), p<0.0001) and sagittal (26 mm (21 to 30), p<0.0001) lengths as well as in the area of the zone of apposition (62 cm2 (3 to 100), p<0.0001) with a decrease in the coronal (8 mm (-12 to -4), p<0.0001) and sagittal (9 mm (-18 to -2), p=0.0029) radii of curvature. CONCLUSIONS: Endoscopic lung volume reduction modifies the diaphragm shape by increasing its length and its zone of apposition and by decreasing its radius of curvature on the treated side, resulting in an increase in its strength. TRIAL REGISTRATION NUMBER: NCT05799352.


Asunto(s)
Diafragma , Neumonectomía , Enfisema Pulmonar , Tomografía Computarizada por Rayos X , Humanos , Diafragma/diagnóstico por imagen , Masculino , Neumonectomía/métodos , Femenino , Persona de Mediana Edad , Anciano , Enfisema Pulmonar/cirugía , Enfisema Pulmonar/fisiopatología , Enfisema Pulmonar/diagnóstico por imagen , Broncoscopía/métodos , Fuerza Muscular/fisiología , Capacidad Residual Funcional/fisiología
3.
Adv Gerontol ; 37(1-2): 144-148, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38944785

RESUMEN

Research on the condition of the lungs in senile people is an urgent task. This is due to the fact that degenerative or age-associated changes in the respiratory system play an important role in the formation of senile asthenia syndrome and a decrease in the age-related viability of the body as a whole. CT-scans of patients aged 80-90 years were analyzed (n=31). Age-associated changes were evaluated: the presence of linear fibrosis, increased pulmonary pattern by the type of reticular (reticular) changes, the presence of gross fibrous reticular changes with cystic cavities and air bullae (by the type of «cellular lung¼), as well as the presence of pulmonary emphysema. Most naturally, senile people show changes characteristic of linear pulmonary fibrosis and emphysema. The progression of the process leads to diffuse reticular changes in the interalveolar and intersegmental septa and, in adverse cases, to the formation of gross changes in the type of «cellular lung¼. Fibro-emphysematous changes are significantly more common in men. A microbiological study of the microbiota of the lower respiratory tract in elderly people was also carried out (n=16). When studying the microbiocenosis of the lower respiratory tract in elderly people, the following data were obtained: resident microflora was found in 71% and clinically significant microorganisms were found in 29%.


Asunto(s)
Microbiota , Enfisema Pulmonar , Humanos , Anciano de 80 o más Años , Masculino , Femenino , Enfisema Pulmonar/microbiología , Enfisema Pulmonar/fisiopatología , Enfisema Pulmonar/diagnóstico , Microbiota/fisiología , Pulmón/microbiología , Tomografía Computarizada por Rayos X/métodos , Fibrosis Pulmonar/fisiopatología , Fibrosis Pulmonar/microbiología , Fibrosis Pulmonar/diagnóstico , Fibrosis Pulmonar/etiología , Envejecimiento/fisiología
4.
BMJ Open ; 14(5): e080518, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38806430

RESUMEN

INTRODUCTION: Application of vapour ablation as a novel approach to lung volume reduction has positive effects in patients with severe emphysema. The BENTO study is a randomised, controlled, open, multicentre trial, to assess the effects of bronchoscopic thermal vapour ablation (BTVA) in the German healthcare system. METHODS AND ANALYSIS: Patients with bilateral heterogeneous emphysema of the upper lobes in Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage 3/4 will be enrolled in this trial and will receive either standard medical management alone (according to GOLD guidelines) or BTVA treatment with the InterVapor system together with standard medical management. Patients will be randomised in a 2:1 ratio (treatment group:control group). A total of 224 patients will be enrolled at 15 study sites. The primary endpoint is the change in patient-reported disease-specific quality of life, as measured by the St George's Respiratory Questionnaire for chronic obstructive pulmonary disease patients between randomisation and the 9-month follow-up visit. Secondary endpoints include adverse events, mortality, vital status, changes in lung function parameters, exercise capacity and other efficacy measures at 3, 9 and 12 months.The BENTO trial was commissioned by the German Federal Joint Committee, to demonstrate that this approach is an efficient and safe treatment option in the German healthcare system. ETHICS AND DISSEMINATION: The protocol has been approved by the lead ethics committee in Germany (Ethics Committee of the Medical Faculty of Heidelberg) and until present also by the following ethics committees: Ethics Committee of the Medical Faculty of Duisburg-Essen, Ethics Committee of the Medical Faculty of Martin-Luther-University Halle-Wittenberg, Ethics Committee of the State Medical Association of Hessen, Ethics Commission of the State Office for Health and Social Affairs of the State of Berlin, Ethics Committee of the Medical Faculty of Greifswald. The results will be published in a peer-reviewed journal. TRIAL REGISTRATION NUMBER: NCT05717192.


Asunto(s)
Broncoscopía , Neumonectomía , Enfisema Pulmonar , Calidad de Vida , Humanos , Alemania , Neumonectomía/métodos , Broncoscopía/métodos , Enfisema Pulmonar/cirugía , Enfisema Pulmonar/fisiopatología , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Enfermedad Pulmonar Obstructiva Crónica/cirugía , Técnicas de Ablación/métodos , Femenino , Masculino , Resultado del Tratamiento
5.
Respirology ; 29(8): 694-703, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38720189

RESUMEN

BACKGROUND AND OBJECTIVE: Both bronchoscopic lung volume reduction with endobronchial valves (BLVR-EBV) and pulmonary rehabilitation (PR) are effective treatments for improving exercise capacity and patient-reported outcomes in patients with severe Chronic Obstructive Pulmonary Disease (COPD). According to current recommendations, all BLVR-EBV patients should have undergone PR first. Our aim was to study the effects of PR both before and after BLVR-EBV compared to BLVR-EBV alone. METHODS: We included patients with severe COPD who were eligible for BLVR-EBV and PR. Participants were randomized into three groups: PR before BLVR-EBV, PR after BLVR-EBV or BLVR-EBV without PR. The primary outcome was change in constant work rate cycle test (CWRT) endurance time at 6-month follow-up of the PR groups compared to BLVR-EBV alone. Secondary endpoints included changes in 6-minute walking test, daily step count, dyspnoea and health-related quality of life. RESULTS: Ninety-seven participants were included. At 6-month follow-up, there was no difference in change in CWRT endurance time between the PR before BLVR-EBV and BLVR-EBV alone groups (median: 421 [IQR: 44; 1304] vs. 787 [123; 1024] seconds, p = 0.82) or in any of the secondary endpoints, but the PR after BLVR-EBV group exhibited a smaller improvement in CWRT endurance time (median: 107 [IQR: 2; 573], p = 0.04) and health-related quality of life compared to BLVR-EBV alone. CONCLUSION: The addition of PR to BLVR-EBV did not result in increased exercise capacity, daily step count or improved patient-reported outcomes compared to BLVR-EBV alone, neither when PR was administered before BLVR-EBV nor when PR was administered after BLVR-EBV.


Asunto(s)
Broncoscopía , Tolerancia al Ejercicio , Neumonectomía , Enfisema Pulmonar , Calidad de Vida , Humanos , Masculino , Femenino , Broncoscopía/métodos , Neumonectomía/métodos , Anciano , Enfisema Pulmonar/cirugía , Enfisema Pulmonar/rehabilitación , Enfisema Pulmonar/fisiopatología , Persona de Mediana Edad , Resultado del Tratamiento , Prueba de Paso , Enfermedad Pulmonar Obstructiva Crónica/rehabilitación , Enfermedad Pulmonar Obstructiva Crónica/cirugía , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Prótesis e Implantes , Factores de Tiempo , Índice de Severidad de la Enfermedad
6.
Int J Chron Obstruct Pulmon Dis ; 19: 1021-1032, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38741941

RESUMEN

Objective: There is an assumption that because EBLVR requires less use of hospital resources, offsetting the higher cost of endobronchial valves, it should therefore be the treatment of choice wherever possible. We have tested this hypothesis in a retrospective analysis of the two in similar groups of patients. Methods: In a 4-year experience, we performed 177 consecutive LVR procedures: 83 patients underwent Robot Assisted Thoracoscopic (RATS) LVRS and 94 EBLVR. EBLVR was intentionally precluded by evidence of incomplete fissure integrity or intra-operative assessment of collateral ventilation. Unilateral RATS LVRS was performed in these cases together with those with unsuitable targets for EBLVR. Results: EBLVR was uncomplicated in 37 (39%) cases; complicated by post-procedure spontaneous pneumothorax (SP) in 28(30%) and required revision in 29 (31%). In the LVRS group, 7 (8%) patients were readmitted with treatment-related complications, but no revisional procedure was needed. When compared with uncomplicated EBLVR, LVRS had a significantly longer operating time: 85 (14-82) vs 40 (15-151) minutes (p<0.001) and hospital stay: 7.5 (2-80) vs 2 (1-14) days (p<0.01). However, LVRS had a similar total operating time to both EBLVR requiring revision: 78 (38-292) minutes and hospital stay to EBLVR complicated by pneumothorax of 11.5 (6.5-24.25) days. Use of critical care was significantly longer in RATS group, and it was also significantly longer in EBV with SP group than in uncomplicated EBV group. Conclusion: Endobronchial LVR does use less hospital resources than RATS LVRS in comparable groups if the recovery is uncomplicated. However, this advantage is lost if one includes the resources needed for the treatment of complications and revisional procedures. Any decision to favour EBLVR over LVRS should not be based on the assumption of a smoother, faster perioperative course.


Asunto(s)
Broncoscopía , Pulmón , Neumonectomía , Enfisema Pulmonar , Procedimientos Quirúrgicos Robotizados , Humanos , Estudios Retrospectivos , Neumonectomía/efectos adversos , Neumonectomía/métodos , Masculino , Persona de Mediana Edad , Broncoscopía/instrumentación , Broncoscopía/métodos , Broncoscopía/efectos adversos , Enfisema Pulmonar/cirugía , Enfisema Pulmonar/fisiopatología , Anciano , Femenino , Resultado del Tratamiento , Procedimientos Quirúrgicos Robotizados/efectos adversos , Procedimientos Quirúrgicos Robotizados/métodos , Factores de Tiempo , Pulmón/cirugía , Pulmón/fisiopatología , Tiempo de Internación , Complicaciones Posoperatorias/etiología , Tempo Operativo , Factores de Riesgo , Neumotórax/cirugía , Toma de Decisiones Clínicas , Readmisión del Paciente
7.
Acta Physiol (Oxf) ; 240(7): e14165, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38747536

RESUMEN

AIM: Chronic obstructive pulmonary disease (COPD) is characterized by progressive airflow obstruction and development of emphysema. Among the comorbidities associated with COPD, skeletal muscle dysfunction is known to affect exercise capacity and the survival rate of patients. Pulmonary rehabilitation (PR), via exercise training, is essential for COPD patients. However, the response to PR is most often moderate. An animal model that recapitulates critical features of chronic human disease and provides access to muscle function should therefore be useful to improve PR benefits. METHODS: We used a rat model of induced emphysema based on pulmonary instillations of elastase (ELA) and lipopolysaccharides (LPS). We assessed the long-term effects of ELA/LPS and the potential effectiveness of endurance training on the skeletal muscle function. In vivo strength of the animals, and ex vivo contractility, endurance, type 1 fiber proportion, fiber cross-sectional area, and capillarization of both soleus and extensor digitorum longus (EDL) were assessed. RESULTS: An impaired overall muscle strength with decreased force, reduced capillarization, and atrophy of type 1 fiber of EDL was observed in ELA/LPS rats. Soleus was not affected. Endurance training was able to reduce fatigability, and increase type 1 fiber proportion and capillarization of soleus, and improve force, endurance, and capillarization of EDL in control and ELA/LPS rats. CONCLUSION: Our rat model of induced emphysema, which shares some features with the phenotype present in patients with COPD, could represent a suitable model to study skeletal muscle dysfunction and the effects of exercise training on muscle function in patients.


Asunto(s)
Modelos Animales de Enfermedad , Músculo Esquelético , Condicionamiento Físico Animal , Enfisema Pulmonar , Animales , Enfisema Pulmonar/fisiopatología , Músculo Esquelético/fisiopatología , Condicionamiento Físico Animal/fisiología , Ratas , Masculino , Fuerza Muscular/fisiología , Ratas Sprague-Dawley , Ratas Wistar
8.
Acta Biomater ; 181: 282-296, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38705223

RESUMEN

Irreversible alveolar airspace enlargement is the main characteristic of pulmonary emphysema, which has been extensively studied using animal models. While the alterations in lung mechanics associated with these morphological changes have been documented in the literature, the study of the mechanical behavior of parenchymal tissue from emphysematous lungs has been poorly investigated. In this work, we characterize the mechanical and morphological properties of lung tissue in elastase-induced emphysema rat models under varying severity conditions. We analyze the non-linear tissue behavior using suitable hyperelastic constitutive models that enable to compare different non-linear responses in terms of hyperelastic material parameters. We further analyze the effect of the elastase dose on alveolar morphology and tissue material parameters and study their connection with respiratory-system mechanical parameters. Our results show that while the lung mechanical function is not significantly influenced by the elastase treatment, the tissue mechanical behavior and alveolar morphology are markedly affected by it. We further show a strong association between alveolar enlargement and tissue softening, not evidenced by respiratory-system compliance. Our findings highlight the importance of understanding tissue mechanics in emphysematous lungs, as changes in tissue properties could detect the early stages of emphysema remodeling. STATEMENT OF SIGNIFICANCE: Gas exchange is vital for life and strongly relies on the mechanical function of the lungs. Pulmonary emphysema is a prevalent respiratory disease where alveolar walls are damaged, causing alveolar enlargement that induces harmful changes in the mechanical response of the lungs. In this work, we study how the mechanical properties of lung tissue change during emphysema. Our results from animal models show that tissue properties are more sensitive to alveolar enlargement due to emphysema than other mechanical properties that describe the function of the whole respiratory system.


Asunto(s)
Elastasa Pancreática , Enfisema Pulmonar , Animales , Enfisema Pulmonar/patología , Enfisema Pulmonar/fisiopatología , Pulmón/patología , Ratas , Masculino , Alveolos Pulmonares/patología , Fenómenos Biomecánicos
9.
Eur J Med Res ; 29(1): 279, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38725073

RESUMEN

PURPOSE: While pharmacologic therapy remains the cornerstone of lung emphysema treatment, surgery is an additional therapeutic option in selected patient groups with advanced emphysema. The aim of lung volume reduction surgery (LVRS) is to improve lung function, exercise capacity, quality of life and survival. We sought to determine the therapeutic value of surgical resection in specific patients with lung emphysema. PATIENTS AND METHODS: A retrospective study was performed consisting of 58 patients with lung emphysema who underwent surgical intervention over a 10-year period and were followed for 2 years postoperatively. The clinical characteristics recorded were FEV1 (forced expiratory volume in 1 s), the 6-min walk test (6-MWT), the Modified Medical Research Council (mMRC), body mass index (BMI) and quality of life prior to and 6, 12 and 24 months after surgical intervention. Moreover, all peri- and post-operative complications were noted. RESULTS: Out of 58 emphysema patients (72% male, FEV1 (L) 2.21 ± 0.17, RV (L) 3.39 ± 0.55), 19 underwent surgical bullectomy, 31 unilateral LVRS and 8 sequential bilateral LVRS. Six months after surgery, there was a statistically significant improvement in FEV1, RV, TLC, 6-MWT and mMRC. Over a period of 12 to 24 months postoperatively, clinical benefit gradually declines most likely due to COPD progression but patients still experienced a significant improvement in FEV1. The most common postoperative complications were persistent air leakage (> 7 days), arrhythmia and subcutaneous emphysema in 60%, 51.6% and 22.4%, respectively. No deaths were observed after surgical intervention. CONCLUSION: In a selected patient population, surgery led to significant improvement of lung function parameters, exercise capacity and quality of life. Over a period of 12 to 24 months postoperatively, clinical benefit gradually decreased most likely due to COPD progression.


Asunto(s)
Neumonectomía , Enfisema Pulmonar , Calidad de Vida , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Enfisema Pulmonar/cirugía , Enfisema Pulmonar/fisiopatología , Estudios de Seguimiento , Neumonectomía/métodos , Anciano , Volumen Espiratorio Forzado , Adulto , Resultado del Tratamiento , Pulmón/cirugía , Pulmón/fisiopatología
10.
Respir Med ; 227: 107639, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38642906

RESUMEN

Bronchoscopic lung volume reduction treatment with Zephyr one-way valves is an effective guideline-based treatment option for patients with severe emphysema and hyperinflation. However, in some cases the treatment response is less than anticipated or there might be a loss of initial treatment effect. Reasons for the lack of response can include incorrect assessment of collateral ventilation, improper valve placement, or patient related factors. Loss of initial benefit can be due to granulation tissue formation and subsequent valve dysfunction, or there may be side effects such as excessive coughing or infectious problems. Careful follow-up after treatment with valves is important and evaluation with a CT scan and/or bronchoscopy is helpful if there is no improvement after treatment or loss of initial benefit. This paper aims to describe the most important causes and provide a strategy of how to approach and manage these patients.


Asunto(s)
Broncoscopía , Neumonectomía , Enfisema Pulmonar , Humanos , Broncoscopía/métodos , Enfisema Pulmonar/cirugía , Enfisema Pulmonar/fisiopatología , Neumonectomía/métodos , Resultado del Tratamiento , Tomografía Computarizada por Rayos X
11.
Ann Am Thorac Soc ; 21(7): 1022-1033, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38530051

RESUMEN

Rationale: Rates of emphysema progression vary in chronic obstructive pulmonary disease (COPD), and the relationships with vascular and airway pathophysiology remain unclear. Objectives: We sought to determine if indices of peripheral (segmental and beyond) pulmonary arterial dilation measured on computed tomography (CT) are associated with a 1-year index of emphysema (EI; percentage of voxels <-950 Hounsfield units) progression. Methods: Five hundred ninety-nine former and never-smokers (Global Initiative for Chronic Obstructive Lung Disease stages 0-3) were evaluated from the SPIROMICS (Subpopulations and Intermediate Outcome Measures in COPD Study) cohort: rapid emphysema progressors (RPs; n = 188, 1-year ΔEI > 1%), nonprogressors (n = 301, 1-year ΔEI ± 0.5%), and never-smokers (n = 110). Segmental pulmonary arterial cross-sectional areas were standardized to associated airway luminal areas (segmental pulmonary artery-to-airway ratio [PAARseg]). Full-inspiratory CT scan-derived total (arteries and veins) pulmonary vascular volume (TPVV) was compared with small vessel volume (radius smaller than 0.75 mm). Ratios of airway to lung volume (an index of dysanapsis and COPD risk) were compared with ratios of TPVV to lung volume. Results: Compared with nonprogressors, RPs exhibited significantly larger PAARseg (0.73 ± 0.29 vs. 0.67 ± 0.23; P = 0.001), lower ratios of TPVV to lung volume (3.21 ± 0.42% vs. 3.48 ± 0.38%; P = 5.0 × 10-12), lower ratios of airway to lung volume (0.031 ± 0.003 vs. 0.034 ± 0.004; P = 6.1 × 10-13), and larger ratios of small vessel volume to TPVV (37.91 ± 4.26% vs. 35.53 ± 4.89%; P = 1.9 × 10-7). In adjusted analyses, an increment of 1 standard deviation in PAARseg was associated with a 98.4% higher rate of severe exacerbations (95% confidence interval, 29-206%; P = 0.002) and 79.3% higher odds of being in the RP group (95% confidence interval, 24-157%; P = 0.001). At 2-year follow-up, the CT-defined RP group demonstrated a significant decline in postbronchodilator percentage predicted forced expiratory volume in 1 second. Conclusions: Rapid one-year progression of emphysema was associated with indices indicative of higher peripheral pulmonary vascular resistance and a possible role played by pulmonary vascular-airway dysanapsis.


Asunto(s)
Progresión de la Enfermedad , Arteria Pulmonar , Enfisema Pulmonar , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Enfisema Pulmonar/diagnóstico por imagen , Enfisema Pulmonar/fisiopatología , Anciano , Persona de Mediana Edad , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiopatología , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Volumen Espiratorio Forzado , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen
12.
Intern Med J ; 54(6): 871-881, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38247402

RESUMEN

BACKGROUND: Endobronchial valve (EBV) insertion for lung volume reduction is a management option for patients with severe emphysema. One-way valves cause lobar deflation and improve lung function, exercise capacity and quality of life. AIMS: To retrospectively analyse and compare the outcomes of the first 57 patients treated with EBVs between 2015 and 2021 at the Royal Adelaide Hospital to international standards. METHODS: Clinical outcomes of forced expiratory volume in 1 s (FEV1), residual volume (RV), treated lobe volume reduction (TLVR) and 6-min walk distance (6MWD) at 3, 6 and 12 months after valve insertion were reviewed against established minimally clinically important differences (MCIDs). Complications and subjective breathlessness measured by Borg scores were also reviewed. RESULTS: Fifty-seven patients were included. At 12 months, 77.2% achieved TLVR. FEV1 improved by 170 mL (95% confidence interval (CI): 100-250, P < 0.001), 80 mL (95% CI: 10-150, P = 0.019) and 40 mL (95% CI: -60 to 130, P 0.66) at 3, 6 and 12 months respectively. RV improved by -610 mL (95% CI: -330 to -900, P < 0.0001) at 3 months, -640 mL (95% CI: -360 to -920, P < 0.0001) at 6 months and -360 mL (95% CI: -60 to -680, P = 0.017) at 12 months. 6MWD improved by 57.34 m (95% CI: 36.23-78.45, P < 0.0001) and 44.93 m (95% CI: 7.19-82.67, P = 0.02) at 3 and 6 months. Borg score improved by -0.53 (95% CI: 0.11 to -1.2, P = 0.11) and -0.49 (95% CI: 0.17 to -1.15, P = 0.16) at 3 and 6 months. Complication rates aligned with international standards with mucous/infection (26.3%) and pneumothorax (17.5%) as the most common. Subgroup analysis signalled improved outcomes in patients with heterogeneous emphysema. CONCLUSION: Our study represents the first publicly funded Australian analysis of EBVs. The results align with international prospective trials demonstrating improved lung function and exercise capacity. Australians with severe emphysema and gas trapping should be referred to a multidisciplinary centre for consideration of EBVs.


Asunto(s)
Neumonectomía , Enfisema Pulmonar , Humanos , Masculino , Femenino , Enfisema Pulmonar/cirugía , Enfisema Pulmonar/fisiopatología , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Australia , Volumen Espiratorio Forzado , Resultado del Tratamiento , Calidad de Vida , Tolerancia al Ejercicio , Prueba de Paso , Broncoscopía/métodos , Índice de Severidad de la Enfermedad , Prótesis e Implantes
13.
J Comput Assist Tomogr ; 48(3): 388-393, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38110294

RESUMEN

OBJECTIVE: The aim of the study is to assess the correlation between artificial intelligence (AI)-based low attenuation volume percentage (LAV%) with forced expiratory volume in the first second to forced vital capacity (FEV1/FVC) and visual emphysema grades in routine chest computed tomography (CT). Furthermore, optimal LAV% cutoff values for predicting a FEV1/FVC < 70% or moderate to more extensive visual emphysema grades were calculated. METHODS: In a retrospective study of 298 consecutive patients who underwent routine chest CT and spirometry examinations, LAV% was quantified using an AI-based software with a threshold < -950 HU. The FEV1/FVC was derived from spirometry, with FEV1/FVC < 70% indicating airway obstruction. The mean time interval of CT from spirometry was 3.87 ± 4.78 days. Severity of emphysema was visually graded by an experienced chest radiologist using an established 5-grade ordinal scale (Fleischner Society classification system). Spearman correlation coefficient between LAV% and FEV1/FVC was calculated. Receiver operating characteristic determined the optimal LAV% cutoff values for predicting a FEV1/FVC < 70% or a visual emphysema grade of moderate or higher (Fleischner grade 3-5). RESULTS: Significant correlation between LAV% and FEV1/FVC was found (ϱ = -0.477, P < 0.001). Increasing LAV% corresponded to higher visual emphysema grades. For patients with absent visual emphysema, mean LAV% was 2.98 ± 3.30, for patients with trace emphysema 3.22 ± 2.75, for patients with mild emphysema 3.90 ± 3.33, for patients with moderate emphysema 6.41 ± 3.46, for patients with confluent emphysema 9.02 ± 5.45, and for patients with destructive emphysema 16.90 ± 8.19. Optimal LAV% cutoff value for predicting a FEV1/FVC < 70 was 6.1 (area under the curve = 0.764, sensitivity = 0.773, specificity = 0.665), while for predicting a visual emphysema grade of moderate or higher, it was 4.7 (area under the curve = 0.802, sensitivity = 0.766, specificity = 0.742). Furthermore, correlation between visual emphysema grading and FEV1/FVC was found. In patients with FEV1/FVC < 70% a high proportion of subjects had emphysema grade 3 (moderate) or higher, whereas in patients with FEV1/FVC ≥ 70%, a larger proportion had emphysema grade 3 (moderate) or lower. The sensitivity for visual emphysema grading predicting a FEV1/FVC < 70% was 56.3% with an optimal cutoff point at a visual grade of 4 (confluent), demonstrating a lower sensitivity compared with LAV% (77.3%). CONCLUSIONS: A significant correlation between AI-based LAV% and FEV1/FVC as well as visual CT emphysema grades can be found in routine chest CT suggesting that AI-based LAV% measurement might be integrated as an add-on functional parameter in the evaluation of chest CT in the future.


Asunto(s)
Inteligencia Artificial , Enfisema Pulmonar , Espirometría , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Enfisema Pulmonar/diagnóstico por imagen , Enfisema Pulmonar/fisiopatología , Anciano , Volumen Espiratorio Forzado , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Radiografía Torácica/métodos , Índice de Severidad de la Enfermedad , Adulto
14.
Acad Radiol ; 31(6): 2567-2578, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38161089

RESUMEN

RATIONALE AND OBJECTIVES: Ex-smokers without spirometry or CT evidence of chronic obstructive pulmonary disease (COPD) but with mildly abnormal diffusing capacity of the lungs for carbon monoxide (DLCO) are at higher risk of developing COPD. It remains difficult to make clinical management decisions for such ex-smokers without other objective assessments consistent with COPD. Hence, our objective was to develop a machine-learning and CT texture-analysis pipeline to dichotomize ex-smokers with normal and abnormal DLCO (DLCO≥75%pred and DLCO<75%pred). MATERIALS AND METHODS: In this retrospective study, 71 ex-smokers (50-85yrs) without COPD underwent spirometry, plethysmography, thoracic CT, and 3He MRI to generate ventilation defect percent (VDP) and apparent diffusion coefficients (ADC). PyRadiomics was utilized to extract 496 CT texture-features; Boruta and principal component analysis were used for feature selection and various models were investigated for classification. Machine-learning classifiers were evaluated using area under the receiver operator characteristic curve (AUC), sensitivity, specificity, and F1-measure. RESULTS: Of 71 ex-smokers without COPD, 29 with mildly abnormal DLCO had significantly different MRI ADC (p < .001), residual-volume to total-lung-capacity ratio (p = .003), St. George's Respiratory Questionnaire (p = .029), and six-minute-walk distance (6MWD) (p < .001), but similar relative area of the lung < -950 Hounsfield-units (RA950) (p = .9) compared to 42 ex-smokers with normal DLCO. Logistic-regression machine-learning mixed-model trained on selected texture-features achieved the best classification accuracy of 87%. All clinical and imaging measurements were outperformed by high-high-pass filter high-gray-level-run-emphasis texture-feature (AUC=0.81), which correlated with DLCO (ρ = -0.29, p = .02), MRI ADC (ρ = 0.23, p = .048), and 6MWD (ρ = -0.25, p = .02). CONCLUSION: In ex-smokers with no CT evidence of emphysema, machine-learning models exclusively trained on CT texture-features accurately classified ex-smokers with abnormal diffusing capacity, outperforming conventional quantitative CT measurements.


Asunto(s)
Aprendizaje Automático , Capacidad de Difusión Pulmonar , Tomografía Computarizada por Rayos X , Humanos , Masculino , Anciano , Persona de Mediana Edad , Femenino , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Anciano de 80 o más Años , Enfisema Pulmonar/diagnóstico por imagen , Enfisema Pulmonar/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Sensibilidad y Especificidad , Espirometría , Imagen por Resonancia Magnética/métodos
17.
PLoS One ; 17(2): e0263261, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35113939

RESUMEN

PURPOSE: To evaluate the association between the coronavirus disease 2019 (COVID-19) and post-inflammatory emphysematous lung alterations on follow-up low-dose CT scans. METHODS: Consecutive patients with proven COVID-19 infection and a follow-up CT were retrospectively reviewed. The severity of pulmonary involvement was classified as mild, moderate and severe. Total lung volume, emphysema volume and the ratio of emphysema/-to-lung volume were quantified semi-automatically and compared inter-individually between initial and follow-up CT and to a control group of healthy, age- and sex-matched patients. Lung density was further assessed by drawing circular regions of interest (ROIs) into non-affected regions of the upper lobes. RESULTS: A total of 32 individuals (mean age: 64 ± 13 years, 12 females) with at least one follow-up CT (mean: 52 ± 66 days, range: 5-259) were included. In the overall cohort, total lung volume, emphysema volume and the ratio of lung-to-emphysema volume did not differ significantly between the initial and follow-up scans. In the subgroup of COVID-19 patients with > 30 days of follow-up, the emphysema volume was significantly larger as compared to the subgroup with a follow-up < 30 days (p = 0.045). Manually measured single ROIs generally yielded lower attenuation values prior to COVID-19 pneumonia, but the difference was not significant between groups (all p > 0.05). CONCLUSION: COVID-19 patients with a follow-up CT >30 days showed significant emphysematous lung alterations. These findings may help to explain the long-term effect of COVID-19 on pulmonary function and warrant validation by further studies.


Asunto(s)
COVID-19/complicaciones , Enfisema Pulmonar/complicaciones , Enfisema Pulmonar/diagnóstico por imagen , Dosis de Radiación , SARS-CoV-2/genética , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/diagnóstico , COVID-19/virología , Estudios de Casos y Controles , Femenino , Estudios de Seguimiento , Humanos , Pulmón/fisiopatología , Mediciones del Volumen Pulmonar , Masculino , Persona de Mediana Edad , Enfisema Pulmonar/fisiopatología , Estudios Retrospectivos
18.
Respir Res ; 23(1): 15, 2022 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-35073932

RESUMEN

BACKGROUND: There is a strong need for biomarkers to better characterize individuals with COPD and to take into account the heterogeneity of COPD. The blood protein sRAGE has been put forward as promising biomarker for COPD in general and emphysema in particular. Here, we measured plasma sRAGE levels using quantitative LC-MS and assessed whether the plasma sRAGE levels associate with (changes in) lung function, radiological emphysema parameters, and radiological subtypes of emphysema. METHODS: Three hundred and twenty-four COPD patients (mean FEV1: 63%predicted) and 185 healthy controls from the COPDGene study were selected. Plasma sRAGE was measured by immunoprecipitation in 96-well plate methodology to enrich sRAGE, followed by targeted quantitative liquid chromatography-mass spectrometry. Spirometry and HRCT scans (inspiration and expiration) with a 5-year follow-up were used; both subjected to high quality control standards. RESULTS: Lower sRAGE values significantly associated with the presence of COPD, the severity of airflow obstruction, the severity of emphysema on HRCT, the heterogeneous distribution of emphysema, centrilobular emphysema, and 5-year progression of emphysema. However, sRAGE values did not associate with airway wall thickness or paraseptal emphysema. CONCLUSIONS: Rather than being a general COPD biomarker, sRAGE is especially a promising biomarker for centrilobular emphysema. Follow-up studies should elucidate whether sRAGE can be used as a biomarker for other COPD phenotypes as well.


Asunto(s)
Pulmón/diagnóstico por imagen , Enfisema Pulmonar/sangre , Receptor para Productos Finales de Glicación Avanzada/sangre , Tomografía Computarizada por Rayos X/métodos , Capacidad Vital/fisiología , Anciano , Biomarcadores/sangre , Femenino , Humanos , Pulmón/fisiopatología , Masculino , Persona de Mediana Edad , Enfisema Pulmonar/diagnóstico , Enfisema Pulmonar/fisiopatología
19.
Sci Rep ; 12(1): 1435, 2022 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-35082306

RESUMEN

We studied whether in patients with COPD the use of metformin for diabetes treatment was linked to a pattern of lung function decline consistent with the hypothesis of anti-aging effects of metformin. Patients of GOLD grades 1-4 of the COSYCONET cohort with follow-up data of up to 4.5 y were included. The annual decline in lung function (FEV1, FVC) and CO diffusing capacity (KCO, TLCO) in %predicted at baseline was evaluated for associations with age, sex, BMI, pack-years, smoking status, baseline lung function, exacerbation risk, respiratory symptoms, cardiac disease, as well as metformin-containing therapy compared to patients without diabetes and metformin. Among 2741 patients, 1541 (mean age 64.4 y, 601 female) fulfilled the inclusion criteria. In the group with metformin treatment vs. non-diabetes the mean annual decline in KCO and TLCO was significantly lower (0.2 vs 2.3, 0.8 vs. 2.8%predicted, respectively; p < 0.05 each), but not the decline of FEV1 and FVC. These results were confirmed using multiple regression and propensity score analyses. Our findings demonstrate an association between the annual decline of lung diffusing capacity and the intake of metformin in patients with COPD consistent with the hypothesis of anti-aging effects of metformin as reflected in a surrogate marker of emphysema.


Asunto(s)
Diabetes Mellitus/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Metformina/uso terapéutico , Capacidad de Difusión Pulmonar/efectos de los fármacos , Enfermedad Pulmonar Obstructiva Crónica/tratamiento farmacológico , Enfisema Pulmonar/tratamiento farmacológico , Factores de Edad , Anciano , Índice de Masa Corporal , Estudios de Cohortes , Diabetes Mellitus/fisiopatología , Femenino , Volumen Espiratorio Forzado/efectos de los fármacos , Humanos , Pulmón/efectos de los fármacos , Pulmón/fisiopatología , Masculino , Persona de Mediana Edad , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfisema Pulmonar/fisiopatología , Factores Sexuales , Fumar/fisiopatología , Capacidad Vital/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...