1.
Orthopedics ; 44(3): e414-e416, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34039206

RESUMEN

One method of preventing surgical-site infection is lowering intraoperative environmental contamination. The authors sought to evaluate their hospital's operating room (OR) contamination rate and compare it with the remainder of the hospital. They tested environmental contamination in preoperative, intraoperative, and postoperative settings for a total joint arthroplasty patient. A total of 190 air settle plates composed of trypsin soy agar were placed in 19 settings within the hospital. Locations included the OR with light and heavy traffic, with and without masks, jackets, and shoe covers; the substerile room; OR hallways; the sterile equipment processing center; preoperative areas; post-anesthesia care units; orthopedic floors; the emergency department; OR locker rooms and restrooms; a resident's home; and controls. The trypsin soy agar plates were incubated at 36 °C for 48 hours. Colony counts were performed for each plate. Average colony-forming units (CFUs) were calculated in each setting. The highest CFUs were in the OR locker room, at 28 CFUs per plate per hour. Preoperative and post-anesthesia care unit holding areas were 7.4 CFUs and 9.6 CFUs, respectively. The main orthopedic surgical ward had 10.0 CFUs per plate per hour, whereas the VIP hospital ward had 17.0 CFUs per plate per hour. All OR environments had low CFUs. A live OR had slightly higher CFUs than settings without OR personnel. In comparison with the local community household, the OR locker room, restrooms, hospital orthopedic wards, emergency department, preoperative holding, post-anesthesia care unit, and OR hallway all had higher airborne contamination. On the basis of these results, the authors recommend environmental sampling as a simple, fast, inexpensive tool for monitoring airborne contamination. [Orthopedics. 2021;44(3):e414-e416.].


Asunto(s)
Microbiología del Aire , Hospitales , Quirófanos , Infección de la Herida Quirúrgica/prevención & control , Artroplastia de Reemplazo , Recuento de Colonia Microbiana , Servicio de Urgencia en Hospital , Humanos , Habitaciones de Pacientes , Ropa de Protección/microbiología , Equipo Quirúrgico/microbiología , Cuartos de Baño
2.
J Hosp Infect ; 106(2): 254-257, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32795568

RESUMEN

Markers for preoperative skin marking are used several times and bear a risk of transmitting bacteria. Bacterial contamination was assessed by sonication and culture. Antimicrobial susceptibility testing (AST) was performed for facultative pathogens to assess multi-drug resistance (MDR). An accelerated failure time model was applied to assess the statistical relationship between the bacterial contamination and the filling status of markers. Of 45 markers, 13 had a colony count <10 cfu/mL and 32 had counts from 10 to 12,500 cfu/mL. Three markers were colonized by Staphylococcus aureus. No MDR bacteria were found. We recommend single use of markers to reduce transmission risk.


Asunto(s)
Bacterias/aislamiento & purificación , Infecciones Bacterianas/transmisión , Contaminación de Equipos , Cuidados Preoperatorios/instrumentación , Equipo Quirúrgico/microbiología , Antibacterianos/farmacología , Bacterias/clasificación , Recuento de Colonia Microbiana , Farmacorresistencia Bacteriana Múltiple , Humanos , Pruebas de Sensibilidad Microbiana , Infecciones Estafilocócicas/microbiología , Infecciones Estafilocócicas/transmisión
3.
Trans Am Clin Climatol Assoc ; 130: 136-144, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31516177

RESUMEN

A global outbreak of invasive Mycobacterium chimaera infections has been associated with exposure to certain heater-cooler devices (HCDs) used during cardiopulmonary bypass. Outbreak investigations have shown that these HCDs harbor M. chimaera in water circuits and generate bio-aerosols in the operating room, leading to airborne transmission to patients during surgery. Whole genome sequencing data support a common-source outbreak originating at an HCD manufacturing facility. Most clinical infections are associated with implanted devices, diagnosis is often delayed, and treatment requires device removal and prolonged antibiotic therapy. Because it is nearly impossible to eradicate M. chimaera from HCDs using existing disinfection approaches, strict separation of HCD exhaust from operating room air is necessary to prevent patient exposure. Lessons learned from this outbreak include: 1) medical device risks are difficult to predict, requiring improved expert review before approval, and 2) advances in genomics provide powerful tools for outbreak investigation and public health surveillance.


Asunto(s)
Aerosoles , Puente Cardiopulmonar , Brotes de Enfermedades , Infecciones por Mycobacterium no Tuberculosas/epidemiología , Mycobacterium , Infecciones Relacionadas con Prótesis/epidemiología , Equipo Quirúrgico/microbiología , Infección de la Herida Quirúrgica/epidemiología , Microbiología del Agua , Procedimientos Quirúrgicos Cardiovasculares , Humanos , Infecciones por Mycobacterium no Tuberculosas/microbiología , Infecciones por Mycobacterium no Tuberculosas/prevención & control , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/microbiología , Complicaciones Posoperatorias/prevención & control , Implantación de Prótesis , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/prevención & control , Infección de la Herida Quirúrgica/microbiología , Infección de la Herida Quirúrgica/prevención & control , Suiza/epidemiología , Factores de Tiempo , Reino Unido/epidemiología , Estados Unidos/epidemiología
4.
J Laryngol Otol ; 133(5): 436-440, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31006387

RESUMEN

BACKGROUND: Medical equipment can transmit pathogenic bacteria to patients. This single-institution point prevalence study aimed to characterise the types and relative amount of bacteria found on surgical loupes, headlights and their battery packs. METHOD: Surgical loupes, headlights and battery packs of 16 otolaryngology staff and residents were sampled, cultured and quantified. Plate scores were summed for each equipment type, and the total was divided by the number of users to generate mean bacterial burden scores. Residents completed a questionnaire regarding their equipment cleaning practices. RESULTS: The contamination rates of loupes, headlights and battery packs were 68.75 per cent, 100 per cent and 75 per cent, respectively. Battery packs cultured more bacteria (1.58 per swab ± 1.00) than loupes (0.75 per swab ± 0.66; p = 0.024). Headlights had non-significantly greater growth (1.50 per swab ± 0.71) than loupes (p = 0.052). Bacterial growth was significantly higher from inner surfaces of loupes (p = 0.035) and headlights (p = 0.037). Potentially pathogenic bacteria were cultured from the equipment of five participants, including: Pantoea agglomerans, Acinetobacter radioresistens, Staphylococcus aureus, Acinetobacter calcoaceticus baumannii complex and Moraxella osloensis. CONCLUSION: This study demonstrates that surgical loupes and headlights used in otolaryngology harbour non-pathogenic skin flora and potentially pathogenic bacteria.


Asunto(s)
Bacterias/crecimiento & desarrollo , Contaminación de Equipos , Iluminación/instrumentación , Procedimientos Quirúrgicos Otorrinolaringológicos/instrumentación , Equipo Quirúrgico/microbiología , Humanos
5.
J Am Assoc Lab Anim Sci ; 58(2): 235-239, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30813984

RESUMEN

level and improve surgical outcomes. Recently, some institutions have approved the use of Press'n Seal cling film (CF; Glad Products, Oakland, CA) as a practical, cost-effective alternative to sterile drapes for rodent surgeries. The purpose of this study was to evaluate the sterility of CF by using ATP and replicate organism detection and counting (RODAC) plates. We tested 10 boxes of CF at days 0, 14, and 28 after opening the box and compared the results with traditional packaged sterile drapes. Our data indicated that CF ATP bioluminescence remained at or below 10 relative light units for 28 d after opening the box. In addition, RODAC plates had no growth for 70% of CF boxes at day 0, 100% at day 14, and 90% at day 28. The mean growth for the positive plates was 0.024 cfu/cm² sampled after contacting locations on the front and back of the CF. The results of this study support the use of CF as an acceptable alternative to traditional sterile drapes during rodent aseptic surgery.


Asunto(s)
Bacterias/aislamiento & purificación , Roedores , Equipo Quirúrgico/microbiología , Animales , Contaminación de Equipos/prevención & control , Ciencia de los Animales de Laboratorio , Mediciones Luminiscentes , Células Madre , Equipo Quirúrgico/normas
6.
J Comput Assist Tomogr ; 43(3): 359-366, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30801564

RESUMEN

Several complications may be encountered after rotator cuff (RC) repair. A thorough knowledge of surgical interventions, normal postoperative findings, and postoperative complications is crucial to provide a timely diagnosis, improving the clinical outcome of patients. Postoperative complications may involve RC, implanted device, osteochondral tissue, surgical-site infection, peripheral nerves, soft tissues, and vascular structures. In this review, we discuss the usual and unusual complications detectable after RC repair.


Asunto(s)
Complicaciones Posoperatorias/clasificación , Lesiones del Manguito de los Rotadores/cirugía , Adulto , Anciano , Comorbilidad , Diagnóstico Precoz , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Lesiones del Manguito de los Rotadores/complicaciones , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Equipo Quirúrgico/efectos adversos , Equipo Quirúrgico/microbiología , Resultado del Tratamiento
8.
Obes Surg ; 28(10): 3352-3359, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30030727

RESUMEN

BACKGROUND: While there are various techniques to create the gastrojejunostomy during a laparoscopic Roux-en-Y gastric bypass (LRYGB), many surgeons prefer using a circular stapler. One drawback of this method, however, is the higher incidence of surgical site infections (SSIs). To investigate the effect of a dual ring wound protector on SSIs during LRYGB. METHODS: In April 2016, our bariatric surgical group implemented an intervention whereby a dual ring wound protector in conjunction with a conical EEA stapler introducer was used when creating the gastrojejunostomy. SSIs from pre- and post-intervention were compared using Fisher's exact test. Only LRYGBs performed with a circular stapler were included in our analysis. Student's t test and χ2 were used to compare pre- and post-intervention groups with respect to demographics and co-morbidities. RESULTS: Between April 2015 and January 31st, 2017, our surgeons performed 158 LRYGBs using a circular stapler for the gastrojejunostomy. There were 84 patients (53%) in the pre-intervention group and 74 (47%) in the post-intervention group. The pre- and post-intervention groups were not statistically different. The SSI rate for the pre-intervention group was 9.5% while the SSI rate was 1.35% in the post-intervention group (p = 0.0371). The use of a dual ring wound protector for LRYGBs with circular stapled gastrojejunostomy was associated with an 86% relative risk reduction in SSIs. CONCLUSION: Using a dual ring wound protector in conjunction with a conical EEA introducer for LRYGBs with circular stapled gastrojejunostomy significantly decreased SSIs.


Asunto(s)
Derivación Gástrica/efectos adversos , Laparoscopía/efectos adversos , Obesidad Mórbida/cirugía , Equipos de Seguridad , Equipo Quirúrgico , Infección de la Herida Quirúrgica/prevención & control , Suturas , Adulto , Contaminación de Equipos/prevención & control , Diseño de Equipo , Femenino , Derivación Gástrica/instrumentación , Derivación Gástrica/métodos , Derivación Gástrica/estadística & datos numéricos , Humanos , Incidencia , Laparoscopía/instrumentación , Laparoscopía/métodos , Laparoscopía/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Obesidad Mórbida/epidemiología , Equipos de Seguridad/estadística & datos numéricos , Estudios Retrospectivos , Equipo Quirúrgico/efectos adversos , Equipo Quirúrgico/microbiología , Equipo Quirúrgico/estadística & datos numéricos , Instrumentos Quirúrgicos/efectos adversos , Instrumentos Quirúrgicos/microbiología , Instrumentos Quirúrgicos/estadística & datos numéricos , Grapado Quirúrgico/efectos adversos , Grapado Quirúrgico/instrumentación , Grapado Quirúrgico/métodos , Grapado Quirúrgico/estadística & datos numéricos , Infección de la Herida Quirúrgica/epidemiología , Suturas/efectos adversos , Suturas/microbiología , Suturas/estadística & datos numéricos
10.
BMC Infect Dis ; 18(1): 68, 2018 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-29409447

RESUMEN

BACKGROUND: Nosocomial infections are a major setback in the healthcare delivery system especially in developing countries due to the limited resources. The roles played by medical care equipment and work surfaces in the transmission of such organisms have inevitably contributed to the elevated mortality, morbidity and antibiotic resistances. METHODS: A total 138 samples were collected during the study from Kawolo general hospital. Swab samples were collected from various work surfaces and fomites which consisted of; beds, sink taps, infusion stands, switches, work tables and scissors. Cultures were done and the susceptibility patterns of the isolates were determined using Kirby Bauer disc diffusion method. Data was analyzed using Stata 13 and Microsoft Excel 2013 packages. RESULTS: A total of 44.2% (61/138) of the collected swab specimens represented the overall bacterial contamination of the sampled articles. Staphylococcus aureus and Klebsiella pneumoniae accounted for the highest bacterial contaminants constituting of 75.4% (46/61) and 11.5% (7/61) respectively. Infusion stands and patient beds were found to have the highest bacterial contamination levels both constituting 19.67% (12/61). The highest degree of transmission of organisms to patients was found to be statistically significant for patient beds with OR: 20.1 and P-value 8X10- 4. Vancomycin, ceftriaxone and ciprofloxacin were the most effective antibiotics with 100%, 80% and 80% sensitivity patterns among the isolates respectively. Multi-drug resistant (MDR) Staphylococcus aureus accounted for 52% (24/46) with 4% (1/24) classified as a possible extensively drug resistant (XDR) whereas Gram negative isolates had 27% (4/15) MDR strains out of which 50%(2/4) were classified as possible pan-drug resistant (PDR). CONCLUSION: The high prevalence of bacterial contaminants in the hospital work environment is an indicator of poor or ineffective decontamination. The study findings reiterate the necessity to formulate drug usage policies and re-examine effectiveness of decontamination and sterilization practices within Kawolo general hospital. We also recommend installation of a sound Microbiology unit at the hospital to take on susceptibility testing to check on the empirical use of antibiotics as a way of reducing the rampant elevations in drug resistances.


Asunto(s)
Klebsiella pneumoniae/aislamiento & purificación , Staphylococcus aureus/aislamiento & purificación , Equipo Quirúrgico/microbiología , Antibacterianos/farmacología , Ropa de Cama y Ropa Blanca/microbiología , Ceftriaxona/farmacología , Ciprofloxacina/farmacología , Farmacorresistencia Microbiana/efectos de los fármacos , Bacterias Gramnegativas/efectos de los fármacos , Bacterias Gramnegativas/aislamiento & purificación , Hospitales Generales , Humanos , Klebsiella pneumoniae/efectos de los fármacos , Pruebas de Sensibilidad Microbiana , Mesas de Operaciones/microbiología , Staphylococcus aureus/efectos de los fármacos , Vestimenta Quirúrgica/microbiología , Uganda , Vancomicina/farmacología
11.
Disaster Med Public Health Prep ; 12(3): 415-418, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-28803582

RESUMEN

Excessive rainfall and dam failures resulted in floodwater contaminating our public water supply. The endotoxin risk in the contaminated water created challenges in recovery of sterile processing for our surgical equipment. Recovery plans should include a potable water source and a method to connect it to the required location. We share our solution of plumbing our sterile processing equipment to tanker-transported potable water sources. (Disaster Med Public Health Preparedness. 2018; 12: 415-418).


Asunto(s)
Inundaciones/estadística & datos numéricos , Esterilización/normas , Equipo Quirúrgico/microbiología , Purificación del Agua/métodos , Agua Potable/análisis , Humanos , Esterilización/métodos , Equipo Quirúrgico/provisión & distribución , Purificación del Agua/instrumentación , Abastecimiento de Agua/normas
12.
Ann Clin Microbiol Antimicrob ; 16(1): 39, 2017 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-28511708

RESUMEN

BACKGROUND: Silver nanoparticles (AgNPs) are believed to be emerging tool against various infectious diseases including multi-drug resistant (MDR) bacteria. In the present study, in vitro synthesis of AgNPs was optimized using 1:50 ratio of macerozyme (25 µg/µl) and 1 mM AgNO3 incubated at 80 °C for 8 h. AgNPs were characterized by UV-Visible spectroscopy, dynamic light scattering (DLS), scanning electron microscopy, energy-dispersive X-ray spectroscopy, transmission electron microscopy (TEM) and X-ray diffraction (XRD). RESULTS: Characterization studies suggest the synthesis of elliptical, stable and crystalline AgNPs with an average size of 38.26 ± 0.4 nm calculated using TEM. The XRD pattern revealed the face-centered-cubic (fcc) form of metallic silver. Good shape integrity and dispersion of AgNPs after 1 year of incubation confirmed their stability. AgNPs were exibited the antimicrobial property against ten pathogenic bacteria, three molds and one yeast. The AgNPs also revealed remarkable antimicrobial activity against three MDR strains i.e. Extended spectrum beta-lactamase positive Escherichia coli, Staphylococcus aureus (MRSA) and Teicoplanin resistant Streptococcus Pneumoniae. The AgNPs coated surgical threads (suture) were revealed the remarkble antibacterial activity against three MDR strains. This is the first report to synthesize antimicrobial elliptical AgNPs using enzymes. CONCLUSION: The results suggest the possibilities to develop the nanoparticles coated antimicrobial medical fabric to combat against MDR infection.


Asunto(s)
Antibacterianos/farmacología , Farmacorresistencia Bacteriana Múltiple/efectos de los fármacos , Nanopartículas del Metal/química , Plata/química , Plata/farmacología , Antibacterianos/química , Antiinfecciosos/química , Antiinfecciosos/farmacología , Bacterias/efectos de los fármacos , Materiales Biocompatibles Revestidos , Escherichia coli/efectos de los fármacos , Pruebas de Sensibilidad Microbiana , Tamaño de la Partícula , Staphylococcus aureus/efectos de los fármacos , Streptococcus pneumoniae/efectos de los fármacos , Equipo Quirúrgico/microbiología , Suturas/microbiología , Levaduras/efectos de los fármacos
14.
Indian Pediatr ; 54(3): 211-214, 2017 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-28159943

RESUMEN

OBJECTIVE: To evaluate the utility of endotracheal aspirate microscopy, culture and endotracheal tube tip culture for early diagnosis of ventilator-associated pneumonia in neonates. METHODS: Inborn ventilated neonates were followed-up for ventilator-associated pneumonia using Center for Disease Control and Prevention (CDC) criteria. Endotracheal aspirate microscopy, culture and endotracheal tube tip cultures were performed. RESULTS: Ventilator-associated pneumonia occurred in 28/68 (41%) neonates as per CDC criteria. Endotracheal aspirate microscopy (≥5 polymorphonuclear cells per high power field) and endotracheal aspirate culture had 78.6% and 75% sensitivity, 87.5% and 90% specificity, positive predictive value of 81.5% and 84%, and negative predictive value of 85.4% and 83.72%, respectively. Mean (SD) time of result of microscopy and endotracheal aspirate culture was 55.7 (4.3) h and 108.3 (19.7) h, respectively in comparison to diagnosis made at 143.5 (23.3) h, as per CDC criteria. CONCLUSION: Endotracheal aspirate microscopic examination and culture can be supportive in objective diagnosis of ventilator-associated pneumonia with an added advantage of earlier prediction.


Asunto(s)
Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/instrumentación , Neumonía Asociada al Ventilador/diagnóstico , Equipo Quirúrgico/microbiología , Femenino , Humanos , Recién Nacido , Cuidado Intensivo Neonatal , Masculino , Técnicas Microbiológicas , Microscopía , Neumonía Asociada al Ventilador/epidemiología , Valor Predictivo de las Pruebas
15.
Clin Infect Dis ; 64(3): 335-342, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-27927870

RESUMEN

BACKGROUND: An urgent UK investigation was launched to assess risk of invasive Mycobacterium chimaera infection in cardiothoracic surgery and a possible association with cardiopulmonary bypass heater-cooler units following alerts in Switzerland and The Netherlands. METHODS: Parallel investigations were pursued: (1) identification of cardiopulmonary bypass-associated M. chimaera infection through national laboratory and hospital admissions data linkage; (2) cohort study to assess patient risk; (3) microbiological and aerobiological investigations of heater-coolers in situ and under controlled laboratory conditions; and (4) whole-genome sequencing of clinical and environmental isolates. RESULTS: Eighteen probable cases of cardiopulmonary bypass-associated M. chimaera infection were identified; all except one occurred in adults. Patients had undergone valve replacement in 11 hospitals between 2007 and 2015, a median of 19 months prior to onset (range, 3 months to 5 years). Risk to patients increased after 2010 from <0.2 to 1.65 per 10000 person-years in 2013, a 9-fold rise for infections within 2 years of surgery (rate ratio, 9.08 [95% CI, 1.81-87.76]). Endocarditis was the most common presentation (n = 11). To date, 9 patients have died. Investigations identified aerosol release through breaches in heater-cooler tanks. Mycobacterium chimaera and other pathogens were recovered from water and air samples. Phylogenetic analysis found close clustering of strains from probable cases. CONCLUSIONS: We identified low but escalating risk of severe M. chimaera infection associated with heater-coolers with cases in a quarter of cardiothoracic centers. Our investigations strengthen etiological evidence for the role of heater-coolers in transmission and raise the possibility of an ongoing, international point-source outbreak. Active management of heater-coolers and heightened clinical awareness are imperative given the consequences of infection.


Asunto(s)
Puente Cardiopulmonar/efectos adversos , Contaminación de Equipos , Infecciones por Mycobacterium no Tuberculosas/epidemiología , Micobacterias no Tuberculosas/aislamiento & purificación , Equipo Quirúrgico/microbiología , Infección de la Herida Quirúrgica/epidemiología , Infección de la Herida Quirúrgica/microbiología , Adulto , Anciano , Anciano de 80 o más Años , Microbiología del Aire , Niño , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infecciones por Mycobacterium no Tuberculosas/microbiología , Infecciones por Mycobacterium no Tuberculosas/mortalidad , Infecciones por Mycobacterium no Tuberculosas/transmisión , Micobacterias no Tuberculosas/clasificación , Micobacterias no Tuberculosas/genética , Estudios Retrospectivos , Factores de Riesgo , Infección de la Herida Quirúrgica/mortalidad , Reino Unido/epidemiología , Microbiología del Agua
17.
MMWR Morb Mortal Wkly Rep ; 65(40): 1117-1118, 2016 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-27740609

RESUMEN

In the spring of 2015, investigators in Switzerland reported a cluster of six patients with invasive infection with Mycobacterium chimaera, a species of nontuberculous mycobacterium ubiquitous in soil and water. The infected patients had undergone open-heart surgery that used contaminated heater-cooler devices during extracorporeal circulation (1). In July 2015, a Pennsylvania hospital also identified a cluster of invasive nontuberculous mycobacterial infections among open-heart surgery patients. Similar to the Swiss report, a field investigation by the Pennsylvania Department of Health, with assistance from CDC, used both epidemiologic and laboratory evidence to identify an association between invasive Mycobacterium avium complex, including M. chimaera, infections and exposure to contaminated Stöckert 3T heater-cooler devices, all manufactured by LivaNova PLC (formerly Sorin Group Deutschland GmbH) (2). M. chimaera was described as a distinct species of M. avium complex in 2004 (3). The results of the field investigation prompted notification of approximately 1,300 potentially exposed patients.* Although heater-cooler devices are used to regulate patients' blood temperature during cardiopulmonary bypass through water circuits that are closed, these reports suggest that aerosolized M. chimaera from the devices resulted in the invasive infections (1,2). The Food and Drug Administration (FDA) and CDC have issued alerts regarding the need to follow updated manufacturer's instructions for use of the devices, evaluate the devices for contamination, remain vigilant for new infections, and continue to monitor reports from the United States and overseas (2).


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Infección Hospitalaria/etiología , Contaminación de Equipos , Infecciones por Mycobacterium no Tuberculosas/etiología , Mycobacterium/genética , Mycobacterium/aislamiento & purificación , Equipo Quirúrgico/microbiología , Regulación de la Temperatura Corporal , Humanos , Estados Unidos
19.
Am J Infect Control ; 43(12): 1336-41, 2015 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-26337855

RESUMEN

BACKGROUND: Sterilized packaging systems are designed to maintain the sterility of surgical instruments and devices from the time of sterilization until use. This study evaluated the effectiveness of rigid containers versus wrapped instrument trays, sterilized using North American sterilization protocols, to maintain a sterile internal environment poststerilization when challenged with aerosolized bacteria under dynamic environmental conditions. METHODS: Using a custom aerosol chamber, 111 rigid containers of various durations of use (unused, used <5 years, used 5-9 years) and 161 wrapped trays using 3 grades of sterilization wrap were challenged with ~10(2) colony-forming units per liter of air containing aerosolized Micrococcus luteus with a count median particle size of 1 µm, while simultaneously experiencing air volume exchanges due to vacuum cycles-two 1-psi cycles, three 0.7-psi cycles, and three 0.4-psi cycles-to simulate air exchange events occurring during the sterilization, transportation, and storage of sterilized instrument trays in health care facilities. RESULTS: Of 111 rigid containers tested, 97 (87%) demonstrated bacterial ingress into the container. Of 161 wrapped trays, 0 (0%) demonstrated bacterial ingress into the tray. Contamination rates of rigid containers increased significantly with increasing duration of use. CONCLUSIONS: In this study using a dynamic bacterial aerosol challenge, sterilized wrapped trays demonstrated significantly greater protection than sterilized rigid containers against the ingress of airborne bacteria.


Asunto(s)
Esterilización , Equipo Quirúrgico/microbiología , Aerosoles , Fómites , Micrococcus luteus/aislamiento & purificación , América del Norte , Embalaje de Productos/métodos
20.
Gesundheitswesen ; 77(7): 502-7, 2015 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-26227385

RESUMEN

Following a patient complaint, the Health Department carried out a hygiene inspection of a urological practice in Braunschweig in February 2013. The topic of the complaint was that a patient assumed having acquired a resistant pathogen in the practice. In the subsequent visit, significant hygiene defects were found, particularly with regard to the processing of medical devices. This led to a decision to commit all urological practices in Braunschweig to hygiene inspections as part of a priority project. In retrospect, the hygiene surveys were justified. Deficiencies included inadequate preparation of medical products, procedures in practice inconsistent with hygiene plans, poor knowledge of hygiene procedures among assistant staff and doctors, lack of expertise of assistant staff and lack of hygiene risk awareness by doctors. Positive experiences were: open communication in a good atmosphere with the Practice managers, willingness to change, good cooperation between the Health Authority and the Labor Inspectorate and Physicians' Association. The claimed deficits were corrected by spring 2014 by the practice operators. The consulting expertise of the health authorities was made use of continuously.


Asunto(s)
Infección Hospitalaria/prevención & control , Contaminación de Equipos/prevención & control , Adhesión a Directriz/estadística & datos numéricos , Higiene , Vigilancia en Salud Pública/métodos , Procedimientos Quirúrgicos Urológicos/normas , Alemania , Adhesión a Directriz/normas , Equipo Quirúrgico/microbiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA