Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.843
Filtrar
1.
Sci Rep ; 14(1): 10602, 2024 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-38719935

RESUMEN

Although the application of magnetic compression anastomosis is becoming increasingly widespread, the magnets used in earlier studies were mostly in the shape of a whole ring. Hence, a deformable self-assembled magnetic anastomosis ring (DSAMAR) was designed in this study for gastrointestinal anastomosis. Furthermore, its feasibility was studied using a beagle model. The designed DSAMAR comprised 10 trapezoidal magnetic units. Twelve beagles were used as animal models, and DSAMARs were inserted into the stomach and colon through the mouth and anus, respectively, via endoscopy to achieve gastrocolic magnamosis. Surgical time, number of failed deformations, survival rate of the animals, and the time of magnet discharge were documented. A month later, specimens of the anastomosis were obtained and observed with the naked eye as well as microscopically. In the gastrocolic anastomosis of the 12 beagles, the procedure took 65-120 min. Although a deformation failure occurred during the operation in one of the beagles, it was successful after repositioning. The anastomosis was formed after the magnet fell off 12-18 days after the operation. Naked eye and microscopic observations revealed that the anastomotic specimens obtained 1 month later were well-formed, smooth, and flat. DSAMAR is thus feasible for gastrointestinal anastomosis under full endoscopy via the natural orifice.


Asunto(s)
Anastomosis Quirúrgica , Estudios de Factibilidad , Animales , Perros , Anastomosis Quirúrgica/métodos , Estómago/cirugía , Imanes , Magnetismo , Cirugía Endoscópica por Orificios Naturales/métodos , Cirugía Endoscópica por Orificios Naturales/instrumentación , Colon/cirugía , Masculino
2.
Pediatr Surg Int ; 40(1): 131, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38730091

RESUMEN

PURPOSE: To evaluate the urodynamic changes in patients who have undergone colocystoplasty (CCP), gastrocystoplasty (GCP) and ileocystoplasty (ICP) in a retrospective study. Changes in urinary continence, incidence of pathologic contractions before and after augmentation, alterations of urodynamic parameters were also examined. METHODS: Eighty-four patients were included in the study who underwent bladder augmentation between 1987 and 2017. Group I: 35 patients with CCP. Group II: 18 patients with GCP. Group III: 31 patients with ICP. Cystometry was performed at 3, 6, and every 12 months, then biannually after augmentation. Pre- and postoperative urodynamic changes were analysed statistically. RESULTS: In Group I, two patients and in Group III, one patient remained incontinent after CCP and ICP. Bladder capacity increased significantly, maximal intra-vesical pressure decreased and compliance improved in all groups (p < 0.001). Postoperative studies showed pathologic contractions in the augmented bladder in half of the patients with GCP, in 43% of patients after CCP and 26% of patients with ICP. CONCLUSION: From the urodynamic point of view, ileum is the most adequate option in the long term. Contractions after augmentation might be caused by the remaining peristalsis of the detubularised segment. Further investigations are needed to evaluate pathologic contractions that remained after detubularisation.


Asunto(s)
Íleon , Vejiga Urinaria , Urodinámica , Humanos , Estudios Retrospectivos , Femenino , Masculino , Vejiga Urinaria/fisiopatología , Vejiga Urinaria/cirugía , Niño , Íleon/cirugía , Íleon/fisiopatología , Adolescente , Colon/cirugía , Colon/fisiopatología , Preescolar , Estómago/cirugía , Estómago/fisiopatología , Procedimientos Quirúrgicos Urológicos/métodos , Lactante
3.
Sci Rep ; 14(1): 10055, 2024 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-38698058

RESUMEN

Endoscopic transgastric necrosectomy is crucial in the management of complications resulting from necrotizing pancreatitis. However, both real-time and visual-spatial information is lacking during the procedure, thereby jeopardizing a precise positioning of the endoscope. We conducted a proof-of-concept study with the aim of overcoming these technical difficulties. For this purpose, a three-dimensional (3D) phantom of a stomach and pancreatic necroses was 3D-printed based on spatial information from individual patient CT scans and subsequently integrated into a silicone torso. An electromagnetic (EM) sensor was adjusted inside the endoscope´s working channel. A software interface enabled real time visualization. The accuracy of this novel assistant system was tested ex vivo by four experienced interventional endoscopists who were supposed to reach seven targets inside the phantom in six different experimental runs of simulated endoscopic transgastric necrosectomy. Supported by endoscopic camera view combined with real-time 3D visualization, all endoscopists reached the targets with a targeting error ranging between 2.6 and 6.5 mm in a maximum of eight minutes. In summary, the EM tracking system might increase efficacy and safety of endoscopic transgastric necrosectomy at the experimental level by enhancing visualization. Yet, a broader feasibility study and further technical improvements are mandatory before aiming at implementation into clinical setting.


Asunto(s)
Fenómenos Electromagnéticos , Humanos , Fantasmas de Imagen , Estómago/cirugía , Estómago/diagnóstico por imagen , Pancreatitis Aguda Necrotizante/cirugía , Pancreatitis Aguda Necrotizante/diagnóstico por imagen , Endoscopía/métodos , Páncreas/cirugía , Impresión Tridimensional , Sistemas de Navegación Quirúrgica , Imagenología Tridimensional/métodos
4.
Sci Rep ; 14(1): 10060, 2024 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-38698246

RESUMEN

This study aimed to evaluate the safety and efficiency of hybrid endoscopic submucosal dissection (H-ESD) using a newly developed ALL IN ONE (AIO) snare. This was a matched control study in a porcine model. Five paired simulated stomach lesions 2-2.5 cm in size were removed by H-ESD using an AIO snare or conventional ESD (C-ESD) using an endoscopic knife. The outcomes of the two procedures were compared, including en-bloc resection rates, procedure times, intraprocedural bleeding volumes, muscular injuries, perforations, thicknesses of the submucosal layer in resected specimens, and stomach defects. All simulated lesions were resected en-bloc. Specimens resected by H-ESD and C-ESD were similar in size (7.68 ± 2.92 vs. 8.42 ± 2.42 cm2; P = 0.676). H-ESD required a significantly shorter procedure time (13.39 ± 3.78 vs. 25.99 ± 4.52 min; P = 0.031) and submucosal dissection time (3.99 ± 1.73 vs. 13.1 ± 4.58 min; P = 0.003) versus C-ESD; H-ESD also yielded a faster dissection speed (241.37 ± 156.84 vs. 68.56 ± 28.53 mm2/min; P = 0.042) and caused fewer intraprocedural bleeding events (0.40 ± 0.55 vs. 3.40 ± 1.95 times/per lesion; P = 0.016) than C-ESD. The thicknesses of the submucosal layer of the resected specimen (1190.98 ± 134.07 vs. 1055.90 ± 151.76 µm; P = 0.174) and the residual submucosal layer of the stomach defect (1607.94 ± 1026.74 vs. 985.98 ± 445.58 µm; P = 0.249) were similar with both procedures. The AIO snare is a safe and effective device for H-ESD and improves the treatment outcomes of gastric lesions by shortening the procedure time.


Asunto(s)
Resección Endoscópica de la Mucosa , Mucosa Gástrica , Animales , Resección Endoscópica de la Mucosa/métodos , Resección Endoscópica de la Mucosa/efectos adversos , Resección Endoscópica de la Mucosa/instrumentación , Porcinos , Mucosa Gástrica/cirugía , Gastroscopía/métodos , Tempo Operativo , Neoplasias Gástricas/cirugía , Neoplasias Gástricas/patología , Estómago/cirugía , Modelos Animales
5.
Pediatr Surg Int ; 40(1): 121, 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38703237

RESUMEN

PURPOSE: Rapunzel syndrome is an uncommon condition in children, and its clinical features remain unclear. This study presents the largest single-center series of pediatric cases to date, with the objective of documenting the clinical characteristics and treatment approaches for children with Rapunzel syndrome. METHODS: A retrospective study was conducted in children with Rapunzel syndrome from 2019 to 2023. We recorded age, gender, symptoms, locations of bezoar, complications, and treatment options. RESULTS: Ten patients with Rapunzel syndrome were included. The median age was 9.1 years, with all of whom were female. The most common clinical symptoms were upper abdominal mass (90%), abdominal pain (80%), and nausea and vomiting (50%). Complications occurred in six cases (60%), including small bowel obstruction (20%), severe gastric dilatation (10%), intestinal perforation (10%), choledochodilation (10%), acute pancreatitis with cholecystitis (10%). Preoperative ultrasonography suggested low-echoic foreign bodies continuing to the jejunum or ileocecal region in five cases (50%). Preoperative gastroscopy attempted in four cases (40%) to remove the foreign bodies, all of which failed. All patients underwent surgical treatment, with nine cases undergoing gastric incision foreign body removal, and one case undergoing gastric incision foreign body removal combined with intestinal perforation repair. All patients recovered well. No recurrence was observed during follow-up. CONCLUSION: The accuracy of ultrasound diagnosis in identifying Rapunzel syndrome is high; however, it may lead to misdiagnosis if not complemented with the patient's medical history. Endoscopic presents a heightened treatment risk and a reduced success rate. The condition commonly presents with severe complications, thus making laparotomy a safe and effective option for intervention.


Asunto(s)
Bezoares , Centros de Atención Terciaria , Humanos , Estudios Retrospectivos , Bezoares/cirugía , Bezoares/complicaciones , Bezoares/diagnóstico , Bezoares/diagnóstico por imagen , Niño , Femenino , Preescolar , Adolescente , Estómago/cirugía , Estómago/diagnóstico por imagen , Masculino , Síndrome
7.
Pediatr Transplant ; 28(3): e14769, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38659292

RESUMEN

BACKGROUND: Sir Roy Calne in 1976 described "Biliary reconstruction is the Achilles heel of liver transplantation," and it remains true. In some patients, such as those with short-gut syndrome and concomitant biliary atresia, neither duct to duct nor Roux biliary reconstruction is feasible. METHODS: We present a case of child's third liver transplant (LT), where an innovative extra-anatomical biliary bypass was created using a sleeve from greater curvature of the stomach. RESULTS: The patient is well nearly 10 years following the LT. CONCLUSIONS: This technique could prove to be an important addition to the armamentarium of a surgeon in difficult retransplants and in patients with short-gut syndrome as it provides a viable option with good long-term outcome.


Asunto(s)
Atresia Biliar , Trasplante de Hígado , Humanos , Trasplante de Hígado/métodos , Atresia Biliar/cirugía , Estómago/cirugía , Anastomosis en-Y de Roux , Resultado del Tratamiento , Procedimientos de Cirugía Plástica/métodos , Masculino , Femenino , Reoperación
8.
J Cardiothorac Surg ; 19(1): 232, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627783

RESUMEN

BACKGROUND: The gastric conduit is the most commonly used replacement organ for reconstruction after minimally invasive McKeown esophagectomy. Although the optimal route of gastric conduit remains controversial, the posterior mediastinal route is physiologically preferable but is not without disadvantages. Here, we report the safety and efficacy of a method of gastric conduit reconstruction via the anterior of the pulmonary hilum route. METHODS: We have used the anterior of the pulmonary hilum route since 2021. This procedure involves pulling the gastric conduit up through a substernal tunnel between the right thoracic cavity and the abdominal cavity and passing it into the neck via the anterior of the pulmonary hilum route. In this retrospective study, we compared the clinical outcomes between 20 patients who underwent this procedure and 20 patients who underwent the posterior mediastinal route from 2021 to 2022. RESULTS: No mortality was reported in either group. No significant differences were observed between the two groups in duration of surgery, blood loss, incidence of postoperative complications, and postoperative hospital stay. As a result of the anterior of the pulmonary hilum route, the primary tumor bed and lymph node drainage area were effectively bypassed, which facilitates postoperative adjuvant radiotherapy or chemoradiotherapy. The distance of the gastric conduit accompanying the airway was significantly shorter in the anterior of the pulmonary hilum route group. CONCLUSIONS: Our method is considered to be a safe and useful technique for the reconstruction of gastric conduit.


Asunto(s)
Neoplasias Esofágicas , Esofagectomía , Humanos , Esofagectomía/métodos , Estudios Retrospectivos , Estómago/cirugía , Complicaciones Posoperatorias/etiología , Mediastino/cirugía , Neoplasias Esofágicas/cirugía
10.
J Gastrointest Surg ; 28(4): 351-358, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38583883

RESUMEN

BACKGROUND: Anastomotic leakage (AL) is a determining factor of morbidity and mortality after esophagectomy. Adequate perfusion of the gastric conduit is crucial for AL prevention. This study aimed to determine whether intraoperative angiography using indocyanine green (ICG) fluorescence improves the incidence of AL after McKeown minimally invasive esophagectomy (MIE) with gastric conduit via the substernal route (SR). METHODS: This retrospective cohort study included 120 patients who underwent MIE with gastric conduit via SR for esophageal cancer between February 2019 and April 2023. Of 120 patients, 88 experienced intraoperative angiography using ICG (ICG group), and 32 patients experienced intraoperative angiography without ICG (no-ICG group). Baseline characteristics and operative outcomes, including AL as the main concern, were compared between the 2 groups. In addition, the outcomes among patients in the ICG group with different levels of fluorescence intensity were compared. RESULTS: The ICG and no-ICG groups were comparable in baseline characteristics and operative outcomes. There was no significant difference between the 2 groups regarding the rate of AL (31.0% vs 37.5%; P = .505), median dates of AL (9 vs 9 days; P = .810), and severity of AL (88.9%, 11.11%, and 0.0% vs 66.7%, 16.7%, and 16.7% for grades I, II, and III, respectively; P = .074). Patients in the ICG group with lower intensity of ICG had higher rates of leakage (24.6%, 39.3%, and 100% in levels I, II, and III of ICG intensity, respectively; P = .04). CONCLUSION: The use of ICG did not seem to reduce the rate of AL. However, abnormal intensity of ICG fluorescence was associated with a higher rate of AL, which implies a predictive potential.


Asunto(s)
Neoplasias Esofágicas , Verde de Indocianina , Humanos , Esofagectomía/efectos adversos , Esofagectomía/métodos , Estudios Retrospectivos , Estómago/diagnóstico por imagen , Estómago/cirugía , Estómago/irrigación sanguínea , Fuga Anastomótica/diagnóstico por imagen , Fuga Anastomótica/etiología , Fuga Anastomótica/prevención & control , Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/cirugía , Neoplasias Esofágicas/complicaciones , Imagen Óptica/métodos , Anastomosis Quirúrgica/efectos adversos
11.
Pediatr Surg Int ; 40(1): 112, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38656340

RESUMEN

PURPOSE: This study aims to evaluate different surgical approaches to long-gap esophageal atresia (LGEA) with or without tracheoesophageal fistula (TEF) is unclear. METHODS: A systematic literature review was done comparing gastric transposition versus esophageal lengthening with delayed primary anastomosis in infants with LGEA+/-TEF. The primary outcome was time to full oral feeds. Secondary outcomes were time to full enteric feeds, need for further surgery, growth, mortality, and postoperative adverse events. RESULTS: No comparative studies were found. However, the literature was re-interrogated for non-comparative studies. Four hundred thirty-eight articles were identified and screened, and 18 met the inclusion criteria. All were case series. Forty-three infants underwent gastric transposition, and 106 had esophageal lengthening with delayed primary anastomosis. One study on gastric transposition reported time to full oral feeds, and one study in each group reported growth. Time to full enteric feeds was reported in one study in each group. 30% of infants had further surgery following gastric transposition, including hiatus hernia repair (5/43, 12%) and esophageal dilation (7/43, 16%). Following esophageal lengthening, 62/106 (58%) had anti-reflux surgery, 58/106 (55%) esophageal dilatation and 11/106 (10%) esophageal stricture resection. Anastomotic complications occurred in 13/43 (30%), gastrointestinal in 16/43 (37%), respiratory in 17/43 (40%), and nerve injury in 2/43 (5%) of the gastric transposition group. In the esophageal lengthening group, anastomotic complications occurred in 68/106 (64%), gastrointestinal in 62/106 (58%), respiratory in 6/106 (6%), and none sustained nerve injury. Each group had one death due to a cause not directly related to the surgical procedure. CONCLUSIONS: This systematic review highlights the morbidity associated with both surgical procedures and the variety in reporting outcomes.


Asunto(s)
Anastomosis Quirúrgica , Atresia Esofágica , Esófago , Atresia Esofágica/cirugía , Humanos , Anastomosis Quirúrgica/métodos , Esófago/cirugía , Recién Nacido , Fístula Traqueoesofágica/cirugía , Estómago/cirugía , Resultado del Tratamiento
12.
Sci Rep ; 14(1): 7289, 2024 03 27.
Artículo en Inglés | MEDLINE | ID: mdl-38538657

RESUMEN

Iatrogenic stomach perforation is a detrimental, irreversible, and fatal condition. Traditional surgery and endoscopic suturing clips and devices have been introduced to seal holes and prevent sepsis and disease progression. However, the development of endoscopic devices for perforations remains challenging, with no standard device available. This study investigates the superficial layer approximation strengths of the newly designed ENDOCRAB system for gastric wall defects. Thirty porcine stomachs were prepared ex vivo for the perforation model and distributed equally into three groups: ENDOCRAB system, Through-the-Scope Clip (TTSC), and hand suturing (HS). Both ENDOCRAB and TTSC achieved mucosal-submucosal layer apposition, whereas HS allowed a full-thickness layer. Their air leakage pressure and procedural duration were measured. The analysis of air-leakage pressure demonstrated comparable suture strength between ENDOCRAB (118.5 ± 41.7 mmHg) and HS (127.4 ± 30.2 mmHg, P = 0.812), but inferior strength with TTSC (73.6 ± 21.6 mmHg, P = 0.012). HS achieved the shortest procedural duration, whereas ENDOCRAB and TTSC showed no significant differences. The ENDOCRAB system showed significantly greater strength than the TTSC, was comparable to HS in strength, and required a procedural duration similar to that of the TTSC. Furthermore, long-term in vivo experiments and histological evaluations are essential.


Asunto(s)
Cirugía Endoscópica por Orificios Naturales , Gastropatías , Porcinos , Animales , Estómago/cirugía , Técnicas de Sutura , Instrumentos Quirúrgicos
13.
Anticancer Res ; 44(4): 1719-1726, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38537985

RESUMEN

BACKGROUND/AIM: Anastomotic leakage is one of the most common and serious postoperative complications following esophagectomy. This study analyzed the effect of risk factors, such as the degree of arteriosclerosis, comorbidities, and patient characteristics on the incidence of reconstruction-related complications including anastomotic leakage. Furthermore, the usefulness of tailor-made reconstruction methods was clarified using wide gastric conduit. PATIENTS AND METHODS: Patients who underwent esophagectomy with a gastric conduit for esophageal cancer between 2011 and 2018 were enrolled. In the initial group that underwent esophagectomy between August 2011 and February 2016, gastrointestinal reconstruction was performed using a narrow gastric conduit. In the latter group, reconstruction using subtotal gastric conduit was selected for high-risk patients between March 2016 and March 2018. Postoperative complications including reconstruction-related complications were assessed. RESULTS: The occurrence of anastomotic leakage was significantly associated with the patient's risk in the initial group. The rates of anastomotic leakage and reconstruction-related complications were significantly lower in the latter group than in the initial group (3.2% vs. 23.0%, p=0.001; 27.0% vs. 44.3%, p=0.044). The incidence of all complications was significantly lower in the latter group than in the initial group (28.6% vs. 59.0%, p=0.001). The change in bodyweight loss one year after the operation was significantly lower in the latter group than in the initial group (p=0.042). CONCLUSION: Tailor-made reconstruction using wide gastric conduit for high-risk cases of esophageal cancer could reduce the occurrence of anastomotic leakage and promote a better quality of life after surgery.


Asunto(s)
Arteriosclerosis , Neoplasias Esofágicas , Humanos , Fuga Anastomótica/etiología , Fuga Anastomótica/cirugía , Esofagectomía/efectos adversos , Esofagectomía/métodos , Calidad de Vida , Estómago/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Neoplasias Esofágicas/complicaciones , Arteriosclerosis/cirugía , Arteriosclerosis/complicaciones , Anastomosis Quirúrgica/efectos adversos , Estudios Retrospectivos
14.
Langenbecks Arch Surg ; 409(1): 90, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38466450

RESUMEN

PURPOSE: Near-infrared fluorescence imaging using indocyanine green (ICG-NIFI) can visualize a blood flow in reconstructed gastric tube; however, it depends on surgeon's visual assessment. The aim of this study was to re-analyze the ICG-NIFI data by an evaluator independent from the surgeon and feasibility of creating the time-intensity curve (TIC). METHODS: We retrospectively reviewed 97 patients who underwent esophageal surgery with gastric tube reconstruction between January 2017 and November 2022. From the stored ICG videos, fluorescence intensity was examined in the four regions of interest (ROIs), which was set around the planned anastomosis site on the elevated gastric tube. After creation the TICs using the OpenCV library, we measured the intensity starting point and time constant and assessed the correlation between the anastomotic leakage. RESULTS: Postoperative leakage occurred for 12 patients. The leakage group had significantly lack of blood flow continuity between the right and left gastroepiploic arteries (75.0% vs. 22.4%; P < 0.001) and tended to have slower ICG visualization time assessed by the surgeon's eyes (40 vs. 32 s; P = 0.066). TIC could create in 65 cases. Intensity starting point at all ROIs was faster than the surgeon's assessment. The leakage group tended to have slower intensity starting point at ROI 3 compared to those in the non-leakage group (22.5 vs. 19.0 s; P = 0.087). CONCLUSION: A TIC analysis of ICG-NIFI by an independent evaluator was able to quantify the fluorescence intensity changes that the surgeon had visually determined.


Asunto(s)
Esofagectomía , Estómago , Humanos , Estudios Retrospectivos , Estómago/diagnóstico por imagen , Estómago/cirugía , Estómago/irrigación sanguínea , Esofagectomía/métodos , Verde de Indocianina , Fuga Anastomótica/diagnóstico por imagen , Fuga Anastomótica/etiología , Fuga Anastomótica/cirugía , Anastomosis Quirúrgica/métodos
16.
Afr J Paediatr Surg ; 21(2): 101-106, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38546247

RESUMEN

BACKGROUND: Bezoars are indigestible lumps which are usually found in stomach. Types of bezoar include phytobezoar, trichobezoar, lithobezoar, pharmacobezoar, plasticobezoar, lactobezoar and metal bezoar. Trichobezoars mostly affect females in 20s and 30s with a rarity in paediatrics. Unexplained complaints with a palpable mass are commonly found in these patients. Treatment involves retrieval of mass with searching for others. The purpose of this study was to present data and surgical management of cases with trichobezoars. MATERIALS AND METHODS: We documented a retrospective review of trichobezoars done in our hospital between 2016 and 2022. All demographic data collected included gender and age of cases, composition and extent of bezoar, clinical presentation, imaging modalities, endoscopic trial, surgical approach and outcome. RESULTS: Five cases of gastrointestinal tract (GIT) trichobezoars underwent surgery. All cases were females between (13 and 16 years). Trichobezoars were three gastric, one ileal and one of combined gastric and colonic. Complaints were abdominal pain, vomiting, weight loss and halitosis. Three cases had a palpable abdominal mass. Different radiological modalities were performed. Endoscopic retrieval was tried in one patient and the laparoscopic approach in another one, but the first route failed. Laparotomy followed by gastrotomy, enterotomy and colotomy was done without complications. CONCLUSIONS: Trichobezoars should be suspected in any child with unexplained abdominal complaints or with a palpable abdominal mass, especially in girls. Imaging can be done in different modalities for diagnosis. Endoscopic retrieval could be tried; however, its failure is common, necessitating laparotomy, which has an excellent outcome.


Asunto(s)
Bezoares , Femenino , Humanos , Niño , Masculino , Bezoares/diagnóstico por imagen , Bezoares/cirugía , Estómago/cirugía , Íleon , Vómitos , Dolor Abdominal/diagnóstico , Dolor Abdominal/etiología , Dolor Abdominal/cirugía
18.
Obes Surg ; 34(4): 1286-1294, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38393455

RESUMEN

INTRODUCTION: Several studies have shown the positive effect on weight loss of the banded Roux-en-Y gastric bypass (BRYGB). Thus far, studies describing the 10-year post-operative results are scarce. Therefore, the aim of this study was to describe the weight loss results, effect on associated medical problems, and complication rates during 10 years of follow-up after BRYGB. METHOD: Data were collected from patients who underwent laparoscopic BRYGB with a non-adjustable silicone gastric ring between January 2011 and March 2013. All patients were included when found to be eligible according to the IFSO criteria. RESULTS: One hundred forty-nine patients were included, 110 received a primary BRYGB and 39 received a conversional BRYGB. The primary BRYGB group consisted of 68% female patients with a mean BMI of 44.5 kg/m2 and a mean age of 46 years old. The conversional group consisted of 77% females and had a mean BMI of 34.8 kg/m2 and a mean age of 48 years. At 10-year follow-up, 67.1% of the data was available. Ten-year post-operative 30% total weight loss was seen in the primary group, and 7% in the conversional group. In 10 years, 23% of the patients had complications of which half were ring-related. CONCLUSION: The addition of a silicon ring to the Roux-en-Y gastric bypass may result in substantial and stable weight loss maintenance 10 years post-operative. Furthermore, the number of patients with long-term complications was low and the number of associated medical problems was significantly reduced.


Asunto(s)
Derivación Gástrica , Laparoscopía , Obesidad Mórbida , Humanos , Femenino , Persona de Mediana Edad , Masculino , Derivación Gástrica/métodos , Obesidad Mórbida/cirugía , Estudios de Seguimiento , Estómago/cirugía , Pérdida de Peso , Laparoscopía/métodos , Resultado del Tratamiento , Estudios Retrospectivos
20.
J Am Anim Hosp Assoc ; 60(2): 60-67, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38394697

RESUMEN

Endoscopy is widely used to remove gastric foreign bodies using grasping forceps and loop snares to manipulate and retrieve the foreign material. However, as not all foreign bodies can be removed using conventional endoscopic techniques, this case series describes the use of bottle liners for the removal of gastric foreign bodies in 12 dogs between 2020 and 2023. A 4 oz bottle liner (Drop-Ins) was placed at the end of the endoscope and pushed into the stomach. With the help of forceps introduced into the operating channel, the foreign body was pushed into the bottle liner. The bottle liner containing the foreign body was then extracted with the help of traction threads. The technique was used as the initial retrieval method in 5 dogs because of smooth (i.e., difficult to grasp) or sharp (i.e., that may damage the digestive tract mucosa during removal) foreign bodies and as a rescue procedure in 7 dogs. Foreign body retrieval was successful in all 12 dogs, with minor complications reported in 5 dogs (erosions and bleeding of the gastroesophageal sphincter). The use of a bottle liner represents an affordable alternative to gastrotomy when foreign bodies cannot be grasped with forceps or snares.


Asunto(s)
Enfermedades de los Perros , Cuerpos Extraños , Perros , Animales , Enfermedades de los Perros/cirugía , Estómago/cirugía , Endoscopía Gastrointestinal/métodos , Endoscopía Gastrointestinal/veterinaria , Cuerpos Extraños/cirugía , Cuerpos Extraños/veterinaria , Gastrectomía/veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA